LCP-10G3B4QDRx-G. 10GBASE-LR SFP+ Optical Transceiver FEATURES. Description. Applications. Performance. RoHS compliant

Similar documents
LCP-10G3B4HDR(T)-G. 10GBASE-LR Lite SFP+ Optical Transceiver. Description. Applications. Performance FEATURES. RoHS compliance

LCP-6144A4EDRx. 10GBASE-SR SFP+ Optical Transceiver FEATURES. Description. Applications. RoHS compliant. Compliant to SFP+ Electrical MSA SFF-8431

FCX-11AB5-3XX-XX 155Mbps BIDI SFP TRANSCEIVER(100Km)

GPON OLT Optical Transceiver SFP Module RTXM RTXM Features

1.25G SFP transceiver with DDM function. RTXM191-xxx (DDM) Features

EPON ONU Optical Transceiver SFF Module

FPS CL Burst Mode SFF BIDI EPON ONU TRANSCEIVER(20Km)

1000BASE BX-10 SFP Transceiver modules (with DDM function) WST-SxSCx1-D5CH Series

Stratos Optical HD/SD BNC to "ST" Video Media Converter (Transmitter)

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

100Gbps CFP Optical Transceiver RTXM

Product Specification

100Gb/s CFP2 Optical Transceiver RTXM

User Manual. Portable 4-Channel Laser Source Instrument in Small Benchtop. (QLDS-N series, version 1.0a. March 26, 2014)

OEM REFRIGERANT GAS SENSORS for Leak Detection & Measurement

FIRERAY 5000 range USER GUIDE

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

100Gb/s CFP2 Optical Transceiver RTXM

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

Datasheet: K-22 LO Sensor

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

HM-4201-RTCM High-Temp Real Time Clock Module

ECO N DATE DESCRIPTION OF CHANGE CHG

PureGain TM 2600 Variable Gain EDFA for Metropolitan Networks

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

4 Channel Contact Closure SFP DIN Fiber Link System

FlameGard 5 MSIR HART

RS485 MODBUS Module 8AI

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

Four channel video link For low cost video transmission

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

DS1286 Watchdog Timekeeper

NIDS Dust sensor ED-N-DS-1408

HUM-M2 Humidity Sensor Module Description

Carbon Monoxide Transmitter

SMART dust sensor for air purifier Description SM-ND-02A SM-ND-02A is a dust sensor that detects the dust particle concentration in air by using optic

OVEN INDUSTRIES, INC.

The supplier and installer of the system should be approved by the local civil defence authority.

Smart GPS Antenna A1035-D

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

HM-4201-RTCM High-Temp Real Time Clock Module

Danfoss gas detection units

Dust sensor SM-PWM-01A SPECIFICATION. Product Name: Dust Sensor Model No. : SM-PWM-01A 1 / 12

IFS SFP Tranceivers User Manual

Set-Up Procedures. Before You Start

LASER DIODE NX8316XC nm FOR LONG HAUL 2.5 Gb/s InGaAsP MQW-DFB LASER DIODE TOSA DESCRIPTION APPLICATION FEATURES

Single Channel Video Receive Unit with two Bi-directional Data Channels and one Bi-directional Alarm Channel for a Multimode Fibre Link

condition monitoring WP4086 Condition Monitoring System The WP4086 CMS System surveys vibrations with up to 8 external accelerometers

Product Specification

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

760nm Single mode VCSEL with Peltier Element and Thermistor in TO510

M41T81S. Serial Access Real-Time Clock with Alarms

OPERATOR S MANUAL MODEL AP15/AP15-1/AP15-2 PC-ALARM PANEL

WP4086 Condition Monitoring System

Product Specification

M41T50 Serial Access Digital Input Real-Time Clock with Alarms

EOTec 2C32 Installation Guide

DS1486/DS1486P RAMified Watchdog Timekeeper

C-Bus Four Channel General Input Unit Installation Instructions

FlameGard 5 UV/IR HART

Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer

21-light Remote Annunciator. Owner s Manual

Table of Contents SECTION PAGE SECTION 1 INTRODUCTION Description Features Models... SECTION 2 RS-232 COMMUNICATIONS...

AKSolutions Data Sheet April 2007 AK882X RF POWER MONITOR. Description: Features:

Danfoss gas detection units

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Scanning Laser Range Finder Smart-URG mini UST-10LN Specification

Cooled Butterfly 980nm Pump Laser Module

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Meridian wiredhart. HART Field Device Specification Goldmine Rd. Monroe, NC USA

Rev Flame Detection Sensor. TF100 User Manual

TPM Product Type 107-D108-XNT 64-channel digital output module with pluggable terminal

Miniature Infrared Temperature Sensors with Optional Touch Screen Display. PSC-SSS-PM with touch screen display (-CRT version)

Nov 08 PRODUCT SPECIFICATION SHEET

Analog Input Module IC670ALG630

CTT8 TEMPERATURE MONITOR DEVICE

CM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications

UDC1000 and UDC1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

GMA 301. Operation Manual. Worldwide Supplier of Safety Solutions. Part Number

MODEL 9010/9020 LCD CONTROL UNIT

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories: 150m ISO 9001

Setup Instructions. This manual is only valid for A36D/TPSD Chargers. equipped with a 341S control card with P341S0012 or P341S0013 software

FCD-wire Contents. List of Figures

Installation Manual Tracker 221

Optical Fiber Monitor (OFM) Whitebox WB-OFM-1262-DC

Copyright Notice. Thinklogical, LLC 100 Washington Street Milford, Connecticut U.S.A. Telephone:

Dual System with 2x Independent Channels each of :

DS1386/DS1386P RAMified Watchdog Timekeeper

MO n : 12JMC rév A

Remote NAC Power Supply D7038

DDT-4691 & DDR ASI / SD-SDI 8 Channel Mux Fibre Optic Link. User Manual. IRT Electronics Pty Ltd

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

5000 INSTALLATION GUIDE

Metasys Integrator Compu-Aire Application

SMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features

Addendum HART Communication with the X2200 UV Flame Detector 1.1 4/

Transcription:

10GBASE-LR SFP+ Optical Transceiver FEATURES RoHS compliant Compliant to SFP+ Electrical MSA SFF-8431 Compliant with SFF-8472 MSA Standard LC duplex fiber-optic connector I 2 C for integrated Digital Optical Monitoring Description The LCP-10G3B4QDRx-G is a hot pluggable 10Gbps small form factor plus transceiver module integrated with the high performance 1310nm DFB Laser transmitter, high sensitivity PD-TIA receiver for 10Gbps applications. It is compliant with the SFF-8431 SFP+ Electrical Multi-source Agreement (MSA) with five digital monitoring functions: Temperature, Vcc, Tx optical power, Tx laser bias current and Rx received optical power. Applications 10G LAN switch 10G Ethernet switch/router 10G Fiber channel SAN applications Performance LCP-10G3B4QDRx-G: Link distance up to 10km over 9um SMF 1 Revision: S2

Absolute Maximum Ratings Parameter Symbol Min. Typ. Max. Unit Storage Temperature T S -40 85 Supply Voltage Range @3.3V V CC3-0.5 3.6 V Recommended Operating Conditions Case Operating Temperature LCP-10G3B4QDR-G LCP-10G3B4QDRH-G LCP-10G3B4QDRT-G Parameter Symbol Min. Typ. Max. Unit T C -5-10 -40 +70 +85 +85 Supply Voltage @3.3V V CC3 3.135 3.30 3.465 V Relative Humidity (non condensation) - 5 85 % DC Common Mode Voltage V CM 0 3.6 V Low Speed Electrical Characteristics (V CC =3.135V to 3.465V) Parameter Symbol Min. Typ. Max. Unit Note Total Supply Current I CC 350 ma Power Consumption PC 1.3 W TX_Fault, RX_LOS V OL V OH 0 Host_Vcc-0.5 0.4 Host_Vcc+0.3 V V TX_Disable V IH 2.0 VccT+0.3 V 1 V IL -0.3 0.8 V 1 RS0, RS1 V IL -0.3 0.8 V 2 V IH 2.0 VccT+0.3 V 2 1. Shall be pulled up with 4.7k-10k ohms to 3.3 volt in the module. 2. Shall be pulled low to GND with a >30k ohms resistor in the module. 2 Revision: S2

Optical Transmitter Characteristics Parameter Symbol Min Typ Max Units Notes Signaling speed (nominal) R 10.3125 Gb/s Signaling speed variation from nominal ±100 ppm Center Wavelength λ 1260 1355 nm Side Mode Suppression Ratio SMSR 30 db Optical Modulaion Amplitude OMA -5.2 dbm Average output power AP -8.2 +0.5 dbm Extinction Ratio ER 3.5 db Transmitter eye mask definition {X1, X2, X3, Y1, Y2, Y3} {0.25, 0.40, 0.45, 0.25, 0.28, 0.40} Notes: 1. Even if the TDP < 1 db, the OMA (min) must exceed this value. Transmitter eye mask definition 4. Optical Receive Characteristics Parameter Symbol Min Typ Max Units Notes Signaling speed (nominal) Ts 10.3125 Gb/s Signaling speed variation from nominal ±100 ppm Center Wavelength λ 1260 1355 nm Overload P O 0.5 dbm Receiver sensitivity in OMA RSO -12.6 dbm [1] Stressed Receiver sensitivity in OMA SRS -10.3 dbm [1] LOS De-assert LOS D -18 dbm LOS Assert LOS A -30 dbm Notes: 1. Measured with 2^31-1 PRBS for BER = 10-12. Per IEEE802.3ae 3 Revision: S2

SFP+ Transceiver Electrical Pad Layout 4 Revision: S2

Module Electrical Pin Definition Pin Logic Symbol Name/Description Note 1 VeeT Module Transmitter Ground 1 2 LVTTL-O TX_Fault Module Transmitter Fault 2 3 LVTTL-I TX_Disable Transmitter Disable; Turns off transmitter laser output 3 4 LVTTL-I/O SDA 2- write Serial Interface Data Line 5 LVTTL-I/O SCL 2- write Serial Interface Clock 6 MOD_ABS Module Absent, connected to V ee T or V ee R in the module 4 7 LVTTL-I RS0 Not Implement 8 LVTTL-O RX_LOS Receiver Loss of Signal Indication 2 9 LVTTL-I RS1 Not Implement 10 VeeR Module Receiver Ground 1 11 VeeR Module Receiver Ground 1 12 CML-O RD- Receiver Inverted Data Output 13 CML-O RD+ Receiver Non-Inverter Data Output 14 VeeR Module Receiver Ground 1 15 VccR Module Receiver 3.3V Supply 16 VccT Module Transmitter 3.3V Supply 17 VeeT Module Transmitter Ground 1 18 CML-I TD+ Transmitter Non-Inverted Data Input 19 CML-I TD- Transmitter Inverted Data Input 20 VeeT Module Transmitter Griund 1 Note: 1. The module signal ground pins, VeeR and VeeT, shall be isolated from the module case. 2. This pin is an open collector/drain output pin and shall be pulled up with 4.7k-10k ohms to Host_Vcc on the host board. Pull ups can be connected to multiple power supplies, however the host board design shall ensure that no module pin has voltage exceeding module VccT/R + 0.5V. 3. This pin is an open collector/drain input pin and shall be pulled up with 4.7k-10k ohms to VccT in the Module. 4. This pin shall be pulled up with 4.7k-10k ohms to Host_Vcc on the host board. 5 Revision: S2

Low speed electrical control pins and 2-wire interface In addition to the 2-wire serial interface, the SFP+ module has the following low speed pins for control and status: TX_Fault TX_Disable RS0/RS1 MOD_ABS RX_LOS 1 TX_Fault.TX_Fault is a module output pin that when High, indicates that the module transmitter has detected a fault condition related to laser operation or safety. The TX_Fault output pin is an open drain/collector and must be pulled p to the Host_Vcc with 4.7k-10k ohms on the host board 2 TX_Disable TX_Disable is a module input pin. When TX_Disable is asserted High or Left open, the SFP+ module transmitter output must be turned off. The TX_DIS pin must be pulled up to VccT in the SFP+ module.. 3 RS0/ RS1 RS0 and RS1 are module input rate select pins and are pulled low to VeeT with a > 30kΩ resistor in the module. RS0 is an input hardware pin which optionally selects the optical receive data path rate coverage for an SFP+ module. RS1 is an input hardware pin which optionally selects the optical transmit path data rate coverage for an SFP+ module. 4 MOD_ABS Mod_ABS is pulled up to Host_Vcc with 4.7k-10k ohms on the host board and connected to VeeT or VeeR in the SFP+ module. MOD_ABS is then asserted High when the SFP+ module is physically absent from a host slot. In the SFP MSA (INF8074i) this pin had the same function but is called MOD_DEF0. 5 SCL/ SDA SCL is the 2-wire interface clock and SDA is the 2-wire interface data line. SCL and SDA are pulled up to a voltage in the range of 3.14V to 3.46V on the host. 6 RX_LOS RX_LOS when High indicated an optical signal level below that specified in the relevant standard. The RX_LOS pin is an open drain/collector output and must be pulled up to host Vcc with a 4.7k-10k ohms on the host board. RX_LOS assert min and de-assert max are defined in the relevant standard. To avoid spurious transition of RX_LOS a minimum hysteresis of 0.5 db is recommended. 6 Revision: S2

Recommend Circuit Schematic 7 Revision: S2

Package Outline Drawing for Metal Housing with Bail de-latch Latch Color Identifier Blue LCP-XXXXXXXXXXX XXXXnm XXGBd Class 1 Laser Product YYWWDDLXXXXX NOTES: 1. Unit : mm 2. Color Code : Single Mode is Blue Multi Mode is Black Complies with 21 CFR 1040.10 and 1040.11 Made in x FS 8 Revision: S2

Timing parameters for SFP+ management Parameter Symbol Min. Max. Unit Note TX_DISABLE Assert time t_off 100 µsec 1 TX_DISABLE Negate time t_on 2 msec 2 Time to initialize 2-wire interfase t_2w_start_up 300 msec 3 Time to initialize t_start_up 300 msec 4 Time to initialize cooled t_start_up_cooled module 90 sec 4 Time to Power Up to Level 2 t_power_level2 300 msec 5 Time to Power Down from Level 2 T_power_down 300 msec 6 TX_Fault assert TX_Fault_on 1 msec 7 TX_Fault assert for cooled module TX_Fault_on 50 msec 7 TX_Fault Reset t_reset 10 µsec 8 RS0, RS1 rate select timing t_rs0_fc, for FC RS1_FC 500 µsec 9 RS0, RS1 rate select timing non FC t_rs0, t_rs1 10 msec 9 RX_LOS assert delay t_los_on 100 µsec 10 RX_LOS negate delay t_los_off 100 µsec 11 Notes: 1) Rising edge of TX_Disable to fall of output signal below 10% of nominal. 2) Falling edge of TX_Disable to rise of output signal above 90% of nominal. This only applies in normal operation, not during start up or fault recovery. 3) From power on or negation of TX_Disable. 4) From power on or TX_Disable negated during power up, or TX_Fault recovery, until non-cooled power level 1 part (or non-cooled power level 2 part already enabled at power level 2 for TX_Fault recovery) is fully operational. 5) From falling edge of stop bit enabling power level 2 until non-cooled module is fully operational. 6) From falling edge of stop bit disabling power level 2 until module is within power level 1 requirements. 7) From Occurrence of fault to assertion of TX_Fault. 8) Time TX_Disable must be held High to reset TX_Fault. 9) From assertion till stable output. 10) From Occurrence of loss of signal to assertion of LOS 11) From Occurrence of presence of signal to negation of RX_LOS. 9 Revision: S2

Enhanced Digital Diagnostic Interface The memory map in the following describes an extension to the memory map defined in SFP MSA. The enhanced interface uses the two wire serial bus address 1010001X (A2h) to provide diagnostic information about the module s present operating conditions. 2 wire address 1010000 X (A0h) 2 wire address 1010001 X (A2h) 0 0 Serial ID Defined by SFP MSA (96 bytes) 55 56 Alarm and Warning Thresholds (56 bytes) Cal Constants (40 bytes) 95 96 95 96 Vender Specific (32 bytes) 119 120 Real Time Diagnostic Interface (24 bytes) 127 127 Vender Specific 128 255 Reserved in SFP MSA (128 bytes) 128 247 248 255 User Writable EEPROM (120 bytes) Vender Specific (8 bytes) Digital Diagnostic Memory Map Specific Data Field Descriptions 10 Revision: S2

EEPROM Serial ID Memory Contents (2-Wire Address A0h) Address Hex ASCII Address Hex ASCII Address Hex ASCII 00 03 43 2D - 86 DC 01 04 44 31 1 87 DC 02 07 45 30 0 88 DC 03 20 10G Base-LR 46 47 G 89 DC 04 00 47 33 3 90 DC 05 00 48 42 B 91 DC 06 00 49 34 4 92 68 07 00 50 51 Q 93 F0 08 00 51 44 D 94 03 09 00 52 52 R 95 CS2 Note 5 10 00 53 2D - 96 00 11 03 54 47 G 97 00 12 67 55 20 Note 1 98 00 13 00 56 41 99 00 14 0A 10km 57 20 100 00 15 64 10km 58 20 101 00 16 00 59 20 102 00 17 00 60 05 1310nm 103 00 18 00 61 1E 1310nm 104 00 19 00 62 00 105 00 20 44 D 63 CS1 Note 2 106 00 21 45 E 64 00 107 00 22 4C L 65 1A 108 00 23 54 T 66 00 109 00 24 41 A 67 00 110 00 25 20 68 SN Note 3 111 00 26 20 69 SN 112 00 27 20 70 SN 113 00 28 20 71 SN 114 00 29 20 72 SN 115 00 30 20 73 SN 116 00 31 20 74 SN 117 00 32 20 75 SN 118 00 33 20 76 SN 119 00 34 20 77 SN 120 00 35 20 78 SN 121 00 36 00 79 SN 122 00 37 00 80 SN 123 00 38 00 81 SN 124 00 39 00 82 SN 125 00 40 4C L 83 SN 126 00 41 43 C 84 DC Note 4 127 00 42 50 P 85 DC 128 00 Note 6 Notes: 1) Byte 53: Base on part number. Please reference ordering information. 2) Byte 63: Check sum of bytes 0-62. 3) Byte 68-83: Serial number. 4) Byte 84-91: Date code. 5) Byte 95: Check sum of bytes 64-94. 6) Byte 128 to 255 had been set hex 00. 11 Revision: S2

Digital Diagnostic Monitoring Interface Alarm and Warning Thresholds (2-Wire Address A2h) Address # Bytes Name Value (Dec.) Unit Note 00-01 2 Temp High Alarm Tc(Max.)+8 1 02-03 2 Temp Low Alarm Tc(Min.)-8 04-05 2 Temp High Warning Tc(Max.)+3 06-07 2 Temp Low Warning Tc(Min.)-3 08-09 2 Voltage High Alarm 3.8 Volt 10-11 2 Voltage Low Alarm 2.8 12-13 2 Voltage High Warning 3.5 14-15 2 Voltage Low Warning 3.1 16-17 2 Bias High Alarm I OP *2+35 ma 2 18-19 2 Bias Low Alarm I OP -25 20-21 2 Bias High Warning I OP *2+30 22-23 2 Bias Low Warning I OP 20 24-25 2 TX Power High Alarm 2.5 dbm 26-27 2 TX Power Low Alarm -10.2 28-29 2 TX Power High Warning 1.5 30-31 2 TX Power Low Warning -9.2 32-33 2 RX Power High Alarm 2.5 dbm 34-35 2 RX Power Low Alarm -14.6 36-37 2 RX Power High Warning 1.5 38-39 2 RX Power Low Warning -13.6 40-45 16 Reversed 56-91 36 External Calibration Constants 92-94 3 Reversed 95 1 Checksum 96-97 2 Real Time Temperature 98-99 2 Real Time Supply Voltage 100-101 2 Real Time Tx Bias Current 102-103 2 Real Time Tx Optical Power 104-105 2 Real Time Rx Received Power 106-109 4 Reserved 110 1 Optional Status/ Control Bits 111 1 Reserved 112-119 8 Optional Set of Alarm and Warning Note: 1) T C : Case Operating temperature 2) I OP : Operating current at room temperature. The min. setting current is 0 ma. 12 Revision: S2

State/ Control Bits Byte Bit Name Description 110 7 Tx Disable State Digital state of the Tx disable input pin 110 6 Soft Tx Disable Read/ Write bit that allow software disable of laser 110 5 Reserved 110 4 Rate Select State Rate Select State 110 3 Soft Rate Select Software Rate Select State 110 2 Tx Fault Digital state of the Tx fault output pin 110 1 LOS Digital state of the LOS output pin. 110 0 Data_Ready_Bar NA Optional Set of Alarm and Warning Byte Bit Name Description 112 7 Temp High Alarm Set when internal temperature exceeds high alarm level 112 6 Temp Low Alarm Set when internal temperature is below low alarm level 112 5 Vcc High Alarm Set when internal supply voltage exceeds high alarm level 112 4 Vcc Low Alarm Set when internal supply voltage is below low alarm level 112 3 Tx Bias High Alarm Set when Tx Bias current exceeds high alarm level 112 2 Tx Bias Low Alarm Set when Tx Bias current is below low alarm level 112 1 Tx Power High Alarm Set when Tx output power exceeds high alarm level 112 0 Tx Power Low Alarm Set when Tx output power is below low alarm level 113 7 Rx Power High Alarm Set when received power exceeds high alarm level 113 6 Rx Power Low Alarm Set when received power is below low alarm level 113 5-0 Reserved 116 7 Temp High Warning Set when internal temperature exceeds high warning level 116 6 Temp Low Warning Set when internal temperature is below low warning level 116 5 Vcc High Warning Set when internal supply voltage exceeds high warning level 116 4 Vcc Low Warning Set when internal supply voltage is below low warning level 116 3 Tx Bias High Warning Set when Tx Bias current exceeds high warning level 116 2 Tx Bias Low Warning Set when Tx Bias current is below low warning level 116 1 Tx Power High Warning Set when Tx output power exceeds high warning level 116 0 Tx Power Low Warning Set when Tx output power is below low warning level 117 7 Rx Power High Warning Set when received power exceeds high warning level 117 6 Rx Power Low Warning Set when received power is below low warning level 117 5-0 Reserved Digital Diagnostic Monitor Accuracy Parameter Typical Value Note Transceiver Temperature ± 3 1 Power Supply Voltage ± 3% 2 TX Bias Current ± 10% TX Optical Power ± 3dB RX Optical Power ± 3dB Notes: 1) Temperature is measured internal to the transceiver 2) Voltage is measured internal to the transceiver 13 Revision: S2

Regulatory Compliance Feature Reference Electromagnetic Interference (EMI) FCC Part15 Class B Electrostatic Discharge (ESD) Laser Eye Safety Component Recognition IEC/EN 61000-4-2 MIL-STD-883E EIA-JESD22-A115-A IEC 60825-1:2001 EN 60825 IEC/EN 60950-1 UL60950 Ordering Information for SFP modules LCP-10G3B4QDRX 1 -G X 1 : Temperature Blank: -5 to +70 degree C H: -10 to +85 degree C T: -40 to +85 degree C Appendix A. Document Revision Version No. Date Description S0 2011-10-13 First released S1 2012-05-15 P8: Modified the shielding of module. P1: Correct the photo of module. S2 2012-07-13 P11: Changed the content of address 64 from 01 to 00. 14 Revision: S2