GSME. Industrial-suited fire gas detectors with multiple semiconductor gas-sensors, integrated signal evaluation and M-Bus interface

Similar documents
HOTSPOT

Industrial Fire Detection

HOTSPOT. Industrial-suited parametrizable Infrared heat detectors with integrated signal processing and evaluation

Branching and Connection Box AAB. Operating manual AAB EN11. GTE Industrieelektronik GmbH

Industrial fire alarm systems

HOTSPOT-1000 HOTSPOT Thermographic Surface Temperature Detector. Installation - Operation - Maintenance EN11

Gas Sensor Fire Detector GSME-Ex

Engineering Guideline. pac- Carriers Type Universal

Recalibrate the way you look at gas detection

Danfoss gas detection units

Danfoss gas detection unit Type GD Heavy Duty

Danfoss gas detection units

Engineering Guideline. pac-carriers Type SIEMENS ET-200M Fail-safe signal modules

Quick Selection Guide Fire Systems LSN Periphery

On the job around the clock 24/7: Fire detection systems

Engineering Guideline. pac-carriers Type for Yokogawa ProSafe-RS

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

GSME Tester GTL-2. Operating manual GTL EN10. GTE Industrieelektronik GmbH

The EN54 Part 2 & 4 Fire System

Bionics Instrument. Alarm Handling. Gas Alarm Systems

M2500 Engine Controller Installation Manual

Line Smoke Detector LRMX

Test Unit GTL 100 for Fire Detectors

RS485 MODBUS Module 8AI

Building Technologies SIGMASYS M Multifunctional danger alarm control and indicating panel

Flame Monitors BROCHURE

OOH740, OOHC740 Automatic fire detectors

Interface and EOL Modules 8

LET S PLAY IT SAFE. robecco secure center (RSC) G.A.S. inert control (RIC) dust control (RDC) silo automation (RSA)

DICTATOR Hold-Open Systems for Hazardous Areas

Multi-Gas-Controller MGC2

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

4100S. The operation and functions described in this manual are available from Software Version 4100S onwards.

For Complete Fire and Gas Solutions

PRODUCT INFORMATION. Sounder SG 200. BDL F.01U A3.en / ST FIR/ PRM1 / zab. Page 1 of 10

Ionisation single-tube smoke detector for duct mounting

Motorised Infrared Optical Beam Smoke Detector. User Guide

Intelligent Single Loop Fire Alarm Control Panel

M-Sens 2. Online-Moisture Meter for Solids. Operating Instructions. SWR engineering Messtechnik GmbH

Gas Detection Unit (GDU) GDA, GDC, GDHC, GDHF, GDH

General Routing Interface

Solution F2. Fire Alarm Control Panels one step ahead.

HART XL High Sensitivity Smoke Detection

The new detector from Rafiki

Motorised Infrared Optical Beam Smoke Detector. User Guide

Technical Data. General specifications. Rated operating distance s n 5 mm

PYROsmart. The intelligent infrared early fire detection and extinguishing system

M-Sens 2. Online moisture measurement for solids. Operating Instructions. SWR engineering Messtechnik GmbH PART OF THE ENVEA GROUP

Products and performance

Infra-Red Transit Heat and Flame Sensors. Early warning fire detection to protect conveyors, product and plant

Planning Instructions MEW01776 Revision -

Thermal management for your cabinets!

OH110, OP110, HI110 Automatic fire detectors

Model 5610 Infra-red Transit Heat Sensor

Annunciator Unit SACO 16 D1. Product Guide

ZIOU/230 - MAINS IO INSTRUCTION MANUAL

Sitron s CF Line of Flow Switch Monitors

FDOOT241-A9-Ex Multisensor fire detector

Annunciator unit. Application

Snifter ATEX22 VERSION. User Manual. Distributor

Dräger Polytron 5100 EC Detection of toxic gases and vapors

FIRERAY 5000 range USER GUIDE

Planning Instructions MEW01090 Revision 4

UEZ 2000/1 LSN, UEZ 2000 LSN, Intrusion Control Centers

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

FIRECLASS Networking. Addressable Fire Alarm Control Panels From Software version 21. Product Application and Design Information FC-A-FCNET-A

Different types of Fire Alarm System

Danfoss gas detection Controller unit

S200Plus Triple Infra Red Flame Detector Triple Waveband Infra-Red Flame Detection

Intelligent 2 & 4 Loop Fire Alarm Control Panels

Fire control panels FC726 FC726-XA

Fire Detection systems. UniVario industrial fire detectors for every job

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

Bernstein product overview

Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface and I/O. Assembly

EL-OEM-3 OEM Packaged Voltage Data Logger

Sita200plus. 200detectors. Single loop analogue addressable System

Fire alarm system EBL512 G3

Safer & quicker evacuation From Emergency Lighting Systems to Adaptive Evacuation Systems

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

SIL2-Interface/ -Signal Conditioners Series DuoTec

MINERVA S200Plus. Fire Detection. Triple Waveband Infra-Red Flame Detection. Features: Minerva S200PLUS

FCS-320-TM Series Conventional Aspirating Smoke Detectors

Dräger PIR 7200 Toxic Gas Detection Transmitter

FC2020 Fire control panel

HART XL High Sensitivity Smoke Detection

Gas Controller Module GC-06

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Cerberus FIT conventional system

Operating instructions DVC-P / Bedienungsanleitung Druckregler DVC-P

SecuriFire SecuriLine extended board B5-DXI2

Device Technology. Supply Operating voltage Implemented via the bus KNX: V DC XIB: 12 V DC (rated voltage) Voltage range: 10.

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Who we are? - Nº 1 Spanish fire alarm systems manufacturer years experience in the fire detection field countries worldwide.

P2267 NETWORK INTERFACE

Analogue addressable devices

Why choose Fireray? Why use a Beam Smoke Detector? Product Range.

Notification Appliance Circuit Module

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

XC10 Extinguishing control panels

Transcription:

GSME 408-2001-x GSME Industrial-suited fire gas detectors with multiple semiconductor gas-sensors, integrated signal evaluation and M-Bus interface Characteristics Sturdy design with aluminium diecast housing Extensive tolerance towards humidity and dust thanks to unique diffusion-filter technology Adjustable sensitivity for each gas-sensor avoids false alarms Multi-criteria signal evaluation detects smoldering fires long before ignition Multiple sensor settings for optimized adaption to operation environment Fast and easy installation due to plug-and-play cable for power-supply and data-signals Central data archiving and visualization with service PC Interface-modules for common fire alarm systems Applications Enclosed belt conveyors for bulk materials (e.g. coal, biomass, wood, waste, surrogate fuels, etc.) Storage facilities and bunkers for spontaneously inflammable materials Drives, shredders, dryers, coolers, chutes and funnels Silos and mills for non-explosive materials (for explosive atmospheres see GSME-X...) GSME are compact fire gas detectors. They are part of the Advanced Discovery System ( ADICOS ), which was specifically created to provide reliable early fire detection in industrial surroundings. GSME are based on multiple semiconductor gas-sensors with an intelligent signal processing routine, enabling them to equally detect open and hidden smoldering fires long before complete ignition. The intrusion of surrounding dust and humidity is avoided by a unique diffusion-filter technology, which rules out false alarms due to sensor-pollution. Power-supply and data communication for the detectors in the system are provided over the ADICOS M-Bus. A simple wiring concept with prewired ADICOS system cables and specially designed connection boxes keeps installation simple and fast. A service PC with the ADICOS Manager connected to an ADICOS M-Busmaster or the ADICOS fire alarm panel BMZ-30 can address each detector individually for advanced data-logging and parametrization features. In this way alarm thresholds can be adapted perfectly to the atmosphere around the specific detector. Displaying and analysing gas concentration curves is also a key feature of the software. The new hardware plattform GSME-M4 replaces the previous models GSME-L3, -F, -FR und -HC. www.adicos.com 408-2410-001 EN4.0-10/2016 Page 1 / 5

GSME - Specifications Mechanical dimensions 32 All dimensions in mm. 62 71 36,6 34 90 ADICOS Anschlusskabel 20 Mechanical characteristics Enclosure Coated aluminium diecast (corrosion-resistant) Dimensions x x 62 mm (H x W x D) (without bayonet socket and splash-guard) x 120 x mm (H x W x D) (with bayonet socket and splash-guard) Weight 0,63 kg (without splash-guard) 0,7 kg (without splash-guard) Protection class IP 64 Thermal characteristics Relative humidity 0... 99 % (non-condensing) Temperature range -20... +50 C Electrical characteristics Supply voltage Power consumption Internal fusing M-Bus max. line length M-Bus max. line capacity M-Bus baudrate Limit contact alarm relay Limit contact error relay 20... 4 DC 1A 750 ma 2 km 200 nf 4800 baud 680 Ω, 20 ma max. (Alarm N/O relay) 0 Ω, 4 / 20 ma max. (Error N/C relay) Technical changes reserved. 408-2410-001 EN4.0-10/2016 Page 2 / 5

GSME - Specifications Detection characteristics Sensor combination CO H₂ HC NOx Reaction time > 30 s Detection scenarios Smouldering fires acc. to EN 45/7 Coal smouldering fires ADICOS topology concept ADICOS BMZ-30 External power-supply ADICOS NT V40-A3 (optional) ADICOS-AAB ADICOS M-BUS Further detectors ADICOS Service-PC ADICOS-Detectors Electrical connection Color Signal Limit value contact CONNECTION BOX red Operating voltage black 24... 4 DC non-polarized yellow Relay output X6 i Alarm NO white Relay output X6 o Alarm NO brown Relay output X7 o Störung NC green Relay output X7 i Störung NC pink Coupling module B - in Extension module (optional ab Werk) blue Coupling module A - in purple Coupling module B - out gray Coupling module A - out blue/red gray/pink M-Bus max. 4 non-polarized NT Ext. Module FAS BMZ30 / M-BM NT / USV X7 (St) X6aus (Al) X6ein (Al) LOOP B LOOP A PE PE B1 A1 B2 A2 X6e X7e X6a X7a X7 (St) X6aus (Al) X6ein (Al) LOOP B LOOP A Coupling module option Color Signal Siemens FDnet BOSCH LSNi pink Coupling module B - in FDnet-A ( ) LSN b1 in blue Coupling module A - in FDnet (+) LSN a in purple Coupling module B - out FDnet-B ( ) LSN b2 out gray Coupling module A - out FDnet (+) LSN a out BMZ-Module Analog signal option Color Signal Analog signal Auxiliary relay pink Analog signal 4... 20 ma blue Analog signal 4... 20 ma NC purple Analog signal 0... 5V NO 0... 1 gray Analog signal C R 1 R 2 R 3 R 4 Alarm relay Error relay Standard Standard R1 = 680 Ω R2 = R3 = 0 Ω R4 = GSME Technical changes reserved. 408-2410-001 EN4.0-10/2016 Page 3 / 5

GSME - Application Planning notes for ADICOS-Detectors ATTENTION! In contrast to conventional smoke detectors, positioning GSME properly is a rather sophisticated task. The detectors need to be placed in a way that allows gas emissions from smoldering fires to reach the gas sensors. This requires the study of the thermal characteristics of a building. The most effective mounting place for a GSME is not necessarily right above the place where a fire is expected. Placement and alignment of ADICOS-Detectors has to be done by specialist planners! Mounting GSME have to be mounted with the diffusion-filter pointing downward! Mounting scheme for conveyor belt monitoring with ADICOS Mounting-plate and customized gallows construction ADICOS Mounting-plate 150 130 150 130 A A Mounting scheme for ceiling installation with ADICOS Mounting-plate 6,4 A-A Material: Mounting holes: Aluminium sheet, 3 mm 8 x Ø 6,4 mm Distance 130 mm / 65 mm 183,8 mm (diagonal) Technical changes reserved. 408-2410-001 EN4.0-10/2016 Page 4 / 5 www.adicos.de

Order information Detector configuration Model -Approval M4 = No -Approval X22 = -Zone 22 (ATEX) X20 = -Zone 20 (ATEX/IECEx) Basic configuration ST = Sensor evaluation Standard E1 = Sensor evaluation Extended 1 E2 = Sensor evaluation Extended 2 R1 = Sensor evaluation Robust 1 R2 = Sensor evaluation Robust 2 IN = Sensor evaluation Customized Detector heating 0 = Detector heating inactive 1 = Detector heating active Splash guard 0 = Without splash guard 1 = With splash guard Configuration for COM module 00 = Not configured for COM module 01 = Configured for Siemens pulse transmission module 02 = Configured for Siemens SIGMASYS module 03 = Configured for Siemens FDnet module 04 = Configured for Bosch LSNi module 05 = Configured for Pre-alarm relay module Resistance configuration for alarm relay 01 = Alarm 0R; Normal 02 = Alarm 680R; Normal (Standard) 03 = Alarm 90R; Normal 180R (Securiton) 04 = Alarm 1K; Normal 20K (Minimax) Resistance configuration for error relay 01 = Error 0R; Normal (Standard) 03 = Error 180R; Normal 90R (Securiton) 04 = Error 10K; Normal 20K (Minimax) Reserved Length of connection cable 00 = Kein connection cable (not for X22 and X20) 05 = 5 m connection cable (default for model X22) 07 = 7 m connection cable (default for model X20) 10 = 10 m connection cable 20 = 20 m connection cable 30 = 30 m connection cable 40 = 40 m connection cable 50 = 50 m connection cable GSME M4 ST 1 1 00 02 01 00 00 Technical changes reserved. 408-2410-001 EN4.0-10/2016 Page 5 / 5