U7698E Flame Detector

Similar documents
FS10-R30 Flame Detector

Sponge Cleaner. Manual P/N A English. Issued 05/03 NORDSON (UK) LTD STOCKPORT

Electropneumatic Hot Melt Application Heads EP 34 / EP 34 S / EP 34 SD

Envirocoat Twin Cyclone Powder Coating Booth

Hot Melt Application Head Series PW...

Seal Sentry Series 10 Bead Detection System

Fill Sentry. Automated Fill System. Customer Product Manual Part A. NORDSON CORPORATION

Bulk Melters BM 200 with Piston Pump for 200 l Drums

Bulk Melters BM 200 with Gear/Gerotor Pump for 200 l Drums

FC-2200 Flame Detector

Hot Melt Material Applicator MC 6

Powder Conditioning System

Hot Melt Material Applicator MC 12 / MC 24

Hot Melt Applicator MC 405 for Foil Bags

Fixed Reclaim System

Level Monitor LA 100

Drum Melters DG 21 / DG 201

Liquid Adhesive Detection System Alarm Box

Fluidking. Manual P/N A English NORDSON (UK) LIMITED STOCKPORT UK

Hot Melt Material Applicator MC 7

LA 820 / LA 820 RC Liquid Adhesive Gun

Auto-Flo RT Gun. Customer Product Manual Part A--02. Issued 10/08 NORDSON CORPORATION AMHERST, OHIO USA

Hot Melt Applicators SB60 BoD

Hot Melt Material Applicator MC 4420

DuraDrum Bulk Melters DD200

Series AD-31 and Series L4 Extrusion Handguns

Automatic Hot Melt Melter/Feeder Retrofit Kit Mechanical Float Model. Part104506A

GD-500 Bead Detection System

ColorMax. Engineered Booth. Customer Product Manual P/N A. Issued 11/10

Bulk Melters BM 200 with Piston Pump - EASY Pneumatics -

Hot-melt adhesive extruder EEX40

FillEasy C Adhesive Feed System

Fiber Optic Module. Part B NORDSON CORPORATION AMHERST, OHIO USA

Econo-Coat RCM 8000 Powder Spray Booth Installation Guide

AltaSpray Plus Applicators

Multi-Spectral, Digital, Infrared Electro-Optical. FSC Model No. s. Unitized, Two Stage, Quick Response Flame Detectors.

Bulk Melters AltaPail

AIR LINE HEATER / FILTER HEATER MODEL: A13230

Hot-melt adhesive extruder EEX100

Models: GW/R-T GW/R-2-T GW/R-3-T

Eclipse Self-Check UV Scanner

NHR-2-25 NHR-2-50 NHR-2-80 NHR-8-80 Powder Capacity: 11 kg (25 lb) 23 kg (50 lb) 36 kg (80 lb) 36 kg (80 lb) *Pump Knockouts: *Pump Adapters

HR Powder Feed Hopper

NHR-2-25 NHR-2-50 NHR-2-80 NHR-8-80 Powder Capacity: 11 kg (25 lb) 23 kg (50 lb) 36 kg (80 lb) 36 kg (80 lb) *Pump Knockouts: *Pump Adapters

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator.

Heliport Perimeter Light Type MIJ

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

Remote Temperature Controller

Non-RTD Hot Melt Hose Replacement

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

NH-4 Heaters. Customer Product Manual Part

DF400/DF600. Construction Heaters. Installation and Maintenance Manual

NHR-25 Feed Hopper with Agitator

FLT93 Installation, Operation and Troubleshooting Guide

Mini-Rooter Operating Instructions

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

SAFETY INFORMATION AND WARNINGS

Page 1 of 18. Part# /5/2013

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

TABLE OF CONTENTS 1 INTRODUCTION SHIPPING... 1

Safety Enclosure for Automated Dispensing Systems

Instructions Dual Spectrum Infrared Flame Detector PM-5MPX. 4.1 Rev: 8/

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

Pioneer-R16 Gas Monitor Operator s Manual

HDLV 55-Gallon Powder Drum Unloader

Basic Vehicle Fire Protection Manual

COMPETITIVE INITIATIVE POWDER COATING SPRAY SYSTEM MINES TECHNICAL SPECIFICATION

Safety. Operating instructions UV sensor UVS 10 DANGER WARNING. Contents CAUTION Edition Please read and keep in a safe place

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Service Manual Model 3163

Required Tools The following tools are required for the installation of the kit: Open-end Wrench Set Flat-tip Screwdriver Cross-tip Screwdriver

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

MODELS 304GC, 304GCX, 314GC, and 314GCX

SERVICE MANUAL VC3ED FULL SIZE ELECTRIC CONVECTION OVEN - NOTICE -

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

INSTALLATION INSTRUCTIONS Trade-Wind In-Line Blower / Ventilators

Owner s Manual. For Australian refrigerator models: N304.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

RK-OXY Oxygen Sample-Draw Detector Operator s Manual Part Number: RK Revision: P1 Released: 7/18/02

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

SERVICE AND INSTALLATION MANUAL MODELS HDO(H) OIL FOR YOUR SAFETY

G45 FastTrack. Page 1 of 8

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Emerson Blue Easy Set 1H/1C

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

Eclipse 90 UV Scanner Model A Version 1

Manual No: Revision: E. Groundwater Sensor. Installation Guide

Installation Instructions

MODEL A-316 CARBON MONOXIDE (CO) MONITOR AND ALARM FOR COMPRESSED AIR TESTING

RKA-LEL Sample Draw Combustible Gas Detector

9060 Power Supply Kit for External Cascade

MODELS ASHP, ASHH, ASUP, and ASUH

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-315(C)

Electrical System. Table of Contents. Section 11. Electrical System NOTE: This section applies to applicators with T-style cordsets.

Installation Instructions

Single Doors FIREGUARD Series Use one Master Unit each door or one 2409 Support unit each door. Pairs of Doors

Wiring Instructions for the 2900 Series FIREGUARD Combination Door Closer-Holder and Releasing Device with Integral Smoke Detector

Big Box Virgin Powder Feed System

Transcription:

U7698E Flame Detector Customer Product Manual Issued 3/02 NORDSON CORPORATION AMHERST, OHIO USA

Nordson Corporation welcomes requests for information, comments, and inquiries about its products. General information about Nordson can be found on the Internet using the following address: http://www.nordson.com. Address all correspondence to: Nordson Corporation Attn: Customer Service 555 Jackson Street Amherst, OH 44001 Notice This is a Nordson Corporation publication which is protected by copyright. Original copyright date 1999. No part of this document may be photocopied, reproduced, or translated to another language without the prior written consent of Nordson Corporation. The information contained in this publication is subject to change without notice. 2002 All rights reserved. Trademarks AccuJet, AquaGuard, Asymtek, Automove, Autotech, Blue Box, CF, CanWorks, Century, Clean Coat, CleanSleeve, CleanSpray, Compumelt, Control Coat, Cross-Cut, Cyclo-Kinetic, Dispensejet, DispenseMate, Durafiber, Durasystem, Easy Coat, Easymove Plus, Econo-Coat, EPREG, ETI, Excel 2000, Flex-O-Coat, FlexiCoat, Flexi-Spray, Flow Sentry, Fluidmove, FoamMelt, FoamMix, Helix, Horizon, Hose Mole, Hot Shot, Hot Stitch, Isocoil, Isocore, Iso-Flo, JR, KB30, Little Squirt, Magnastatic, MEG, Meltex, MicroSet, Millennium, Mini Squirt, Moist-Cure, Mountaingate, MultiScan, Nordson, OmniScan, Opticoat, OptiMix, Package of Values, Patternview, PluraFoam, Porous Coat, PowderGrid, Powderware, Prism, Pro-Flo, ProLink, Pro-Meter, Pro-Stream, PRX, RBX, Rhino, S. design stylized, Saturn, SC5, Seal Sentry, Select Charge, Select Coat, Select Cure, Slautterback, Smart-Coat, Spray Squirt, Spraymelt, Super Squirt, Sure Coat, System Sentry, Tela-Therm, Trends, Tribomatic, UniScan, UpTime, Veritec, Versa-Coat, Versa-Screen, Versa-Spray, Walcom, Watermark, and When you expect more. are registered trademarks of Nordson Corporation. ATS, AeroCharge, Auto-Flo, AutoScan, BetterBook, Chameleon, CanNeck, Check Mate, Colormax, Control Weave, Controlled Fiberization, Coolwave, CPX, Dry Cure, E-Nordson, EasyClean, Eclipse, Equi=Bead, Fill Sentry, Fillmaster, Gluie, Heli-flow, Ink-Dot, Iso-Flex, Kinetix, Lacquer Cure, Maxima, MicroFin, Minimeter, Multifil, Origin, PermaFlo, PluraMix, Powder Pilot, Powercure, Primarc, Process Sentry, PurTech, Pulse Spray, Ready Coat, Select Series, Sensomatic, Shaftshield, SheetAire, Spectral, Spectronic, Spectrum, Summit, Sure Brand, Sure Clean, Sure Max, Swirl Coat, Tempus, Tracking Plus, Trade Plus, Universal, Vista, Web Cure, and 2 Rings (Design) are trademarks of Nordson Corporation. Manual 34-49 2002 Nordson Corporation

Table of Contents i Table of Contents Safety.............................................. 1 Qualified Personnel....................................... 1 Intended Use............................................. 1 Regulations and Approvals................................. 1 Personal Safety........................................... 2 Fire Safety............................................... 2 Grounding................................................ 3 Action in the Event of a Malfunction......................... 3 Disposal................................................. 4 Description......................................... 4 Indicators, Alarms, Interlocks, and Controls................... 5 Indicators................................................... 5 Alarm Buzzers............................................... 5 Interlocks................................................... 5 Reset Switch................................................. 5 Detector Heads........................................... 6 Theory of Operation....................................... 7 Flame Detection............................................. 7 Faults...................................................... 7 Installation......................................... 8 Mounting................................................. 8 Pneumatic Connections.................................... 10 Electrical Connections..................................... 11 Detector Heads.............................................. 11 Interlocks................................................... 12 Power Supply............................................... 13 Operation.......................................... 14 Startup.................................................. 14 Normal Mode............................................ 14 Fault Mode.............................................. 14 Major Fault Mode......................................... 15 Fire Mode............................................... 15 Reset................................................... 15 Through-the-Lens Test.................................... 15 Optional Test Lamp....................................... 16 Maintenance....................................... 16 Daily.................................................... 16 Periodic................................................. 16 2002 Nordson Corporation Manual 34-49

ii Table of Contents Troubleshooting.................................... 17 Troubleshooting Chart..................................... 18 Electrical Schematic...................................... 19 Repair............................................. 21 Sensor and Electronics Module Replacement................ 21 Removing the Old Sensor and Electronics Modules............... 21 Installing the New Sensor and Electronics Modules............... 22 Parts............................................... 23 Using the Illustrated Parts List.............................. 23 Detector Head........................................... 24 Indicator Panel............................................ 25 Options............................................ 26 Test Lamp............................................... 26 Air Supply Parts........................................... 26 Specifications...................................... 27 Detector Head Terminal Block Connections.................. 27 Configuration Switch Settings.............................. 27 Interlock Relay Contact Conditions.......................... 27 Weight and Dimensions................................... 28 Electrical Power.......................................... 28 Manual 34-49 2002 Nordson Corporation

U7698E Flame Detector 1 U7698E Flame Detector Safety Read and follow these safety instructions. Task- and equipment-specific warnings, cautions, and instructions are included in equipment documentation where appropriate. Make sure all equipment documentation, including these instructions, is accessible to all persons operating or servicing equipment. Qualified Personnel Equipment owners are responsible for making sure that Nordson equipment is installed, operated, and serviced by qualified personnel. Qualified personnel are those employees or contractors who are trained to safely perform their assigned tasks. They are familiar with all relevant safety rules and regulations and are physically capable of performing their assigned tasks. Intended Use Use of Nordson equipment in ways other than those described in the documentation supplied with the equipment may result in injury to persons or damage to property. Some examples of unintended use of equipment include using incompatible materials making unauthorized modifications removing or bypassing safety guards or interlocks using incompatible or damaged parts using unapproved auxiliary equipment operating equipment in excess of maximum ratings Regulations and Approvals Make sure all equipment is rated and approved for the environment in which it is used. Any approvals obtained for Nordson equipment will be voided if instructions for installation, operation, and service are not followed. All phases of equipment installation must comply with all federal, state, and local codes. 2002 Nordson Corporation Manual 34-49

2 U7698E Flame Detector Personal Safety Fire Safety To prevent injury follow these instructions. Do not operate or service equipment unless you are qualified. Do not operate equipment unless safety guards, doors, or covers are intact and automatic interlocks are operating properly. Do not bypass or disarm any safety devices. Keep clear of moving equipment. Before adjusting or servicing any moving equipment, shut off the power supply and wait until the equipment comes to a complete stop. Lock out power and secure the equipment to prevent unexpected movement. Relieve (bleed off) hydraulic and pneumatic pressure before adjusting or servicing pressurized systems or components. Disconnect, lock out, and tag switches before servicing electrical equipment. Obtain and read Material Safety Data Sheets (MSDS) for all materials used. Follow the manufacturer s instructions for safe handling and use of materials, and use recommended personal protection devices. To prevent injury, be aware of less-obvious dangers in the workplace that often cannot be completely eliminated, such as hot surfaces, sharp edges, energized electrical circuits, and moving parts that cannot be enclosed or otherwise guarded for practical reasons. To avoid a fire or explosion, follow these instructions. Do not smoke, weld, grind, or use open flames where flammable materials are being used or stored. Provide adequate ventilation to prevent dangerous concentrations of volatile materials or vapors. Refer to local codes or your material MSDS for guidance. Do not disconnect live electrical circuits while working with flammable materials. Shut off power at a disconnect switch first to prevent sparking. Know where emergency stop buttons, shutoff valves, and fire extinguishers are located. If a fire starts in a spray booth, immediately shut off the spray system and exhaust fans. Clean, maintain, test, and repair equipment according to the instructions in your equipment documentation. Use only replacement parts that are designed for use with original equipment. Contact your Nordson representative for parts information and advice. Manual 34-49 2002 Nordson Corporation

U7698E Flame Detector 3 Grounding WARNING: Operating faulty electrostatic equipment is hazardous and can cause electrocution, fire, or explosion. Make resistance checks part of your periodic maintenance program. If you receive even a slight electrical shock or notice static sparking or arcing, shut down all electrical or electrostatic equipment immediately. Do not restart the equipment until the problem has been identified and corrected. All work conducted inside the spray booth or within 1 m (3 ft) of booth openings is considered within a Class 2, Division 1 or 2 Hazardous location and must comply with NFPA 33, NFPA 70 (NEC articles 500, 502, and 516), and NFPA 77, latest conditions. All electrically conductive objects in the spray areas shall be electrically connected to ground with a resistance of not more than 1 megohm as measured with an instrument that applies at least 500 volts to the circuit being evaluated. Equipment to be grounded includes, but is not limited to, the floor of the spray area, operator platforms, hoppers, photoeye supports, and blow-off nozzles. Personnel working in the spray area must be grounded. There is a possible ignition potential from the charged human body. Personnel standing on a painted surface, such as an operator platform, or wearing non-conductive shoes, are not grounded. Personnel must wear shoes with conductive soles or use a ground strap to maintain a connection to ground when working with or around electrostatic equipment. Operators must maintain skin-to-handle contact between their hand and the gun handle to prevent shocks while operating manual electrostatic spray guns. If gloves must be worn, cut away the palm or fingers, wear electrically conductive gloves, or wear a grounding strap connected to the gun handle or other true earth ground. Shut off electrostatic power supplies and ground gun electrodes before making adjustments or cleaning powder spray guns. Connect all disconnected equipment, ground cables, and wires after servicing equipment. Action in the Event of a Malfunction If a system or any equipment in a system malfunctions, shut off the system immediately and perform the following steps: Disconnect and lock out electrical power. Close pneumatic shutoff valves and relieve pressures. Identify the reason for the malfunction and correct it before restarting the equipment. 2002 Nordson Corporation Manual 34-49

4 U7698E Flame Detector Disposal Dispose of equipment and materials used in operation and servicing according to local codes. Description The model U7698E flame detector installs in a coating system booth and interfaces with the booth and application equipment controls. The flame detector shuts down the booth, application equipment, and conveyor when it detects a fire in the booth. See Figure 1. The flame detector consists of an indicator panel (1) and one or two detector heads (2). Each detector head has an air shield that keeps the lens clean. 1 2 Figure 1 U7698E Indicator Panel and Flame Detector Head 1. Indicator panel 2. Detector head 1400492A Manual 34-49 2002 Nordson Corporation

U7698E Flame Detector 5 Indicators, Alarms, Interlocks, and Controls The indicator panel houses the flame detector indicators, alarms, interlocks, and controls. Indicators POWER ON (green) DET. HEAD #1 FAULT (amber) DET. HEAD #2 FAULT (amber) FIRE DETECTED (red) Alarm Buzzers FAULT DETECTED (continuous tone) FIRE DETECTED (fast intermittent tone) Interlocks The indicator panel houses three interlock relays: booth conveyor customer use If a fire is detected in the booth, the booth and conveyor interlocks shut down the booth, application equipment, and conveyor. The customer-use interlock relay can be wired to activate an alarm or other external device. Refer to Installation for instructions on wiring these interlocks, and Specifications for the relay contact conditions during fault, major fault, and fire alarms. Reset Switch The DET. HEAD RESET switch is a three-position momentary selector switch. Use the switch to reset the detector heads after correcting a fault. Move the switch to the left to reset detector head 1. Move the switch to the right to reset detector head 2. 2002 Nordson Corporation Manual 34-49

6 U7698E Flame Detector Detector Heads See Figure 2. A detector head consists of an air shield (1), sensor module (2), electronics module (3), housing (4), and connector board (not shown) mounted in the housing. 1 2 4 3 ATTENTION 1400493A Figure 2 Detector Head Components 1. Air shield 2. Sensor module 3. Electronics module 4. Housing Manual 34-49 2002 Nordson Corporation

U7698E Flame Detector 7 A DIN connector mounted on the electronics module plugs into the connector board in the housing. The detector heads scan the IR spectrum. They use intelligent, real-time signal processing to tell the difference between a real fire and false-alarm radiant energy sources. Each detector head continuously monitors itself via a through-the-lens test. Two clear (white) LEDs on the top of the sensor module light to run the test. If the test fails, the detector head goes into fault mode and the amber fault indicator on the panel lights. Each detector head also has two red power LED indicators, visible through the lens. The detector head lens is continuously cleaned by low-pressure air flowing from the air shield. Theory of Operation Power is supplied to the indicator panel from the booth electrical panel. The indicator panel supplies 24 Vdc power to the detector heads. Flame Detection If a flame is detected inside the booth, interlock relays in the indicator panel open and shut down the booth exhaust fan, application equipment, and conveyor. The red FIRE DETECTED indicator lights and the FIRE DETECTED alarm sounds. Faults The DET. HEAD FAULT indicators and and the FAULT DETECTED alarm alert operators to problems with the detector heads. There are two fault modes: Fault: A fault occurs when one detector head loses power, fails a through-the-lens test, or has a sensor or electronics module malfunction. The fault indicator for that detector head lights and the fault alarm sounds. No interlocked equipment is shut down if two detector heads are installed and only one has a fault. If only one detector head is installed, then any fault is a major fault. Major Fault: A major fault occurs when both detector heads lose power, fail a through-the-lens test, or have a sensor or electronics module malfunction. Both fault indicators light and the fault alarm sounds. If only one detector head is installed, then any fault is a major fault. A major fault shuts down the booth and application equipment. The conveyor will continue to run. The conveyor shuts down only if a flame is detected. 2002 Nordson Corporation Manual 34-49

8 U7698E Flame Detector Installation WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Mounting See Figure 3. 1. Measure and mark the locations in the booth entrance and exit vestibules (2) for the detector heads (1). 2. Mount the detector heads to the spray booth entrance and exit vestibule walls or floors, using the mounting brackets (7) and screws, flat washers, lock washers, and nuts (8). 3. Align the detector head centerlines (4) so they have an unobstructed view of the spray guns (3), conveyor (5), hangers, and workpieces (6). Each detector head has an 80-degree, cone-shaped field of view. 4. Mount the indicator panel close to or on the booth electrical panel or on an operator platform using the mounting holes on the panel flanges. Manual 34-49 2002 Nordson Corporation

U7698E Flame Detector 9 6 1 5 4 2 3 1 7 8 2 1400494A Figure 3 Detector Head Installation 1. Detector heads 2. Booth vestibules 3. Spray guns 4. Centerlines 5. Conveyor 6. Hangers and workpieces 7. Mounting bracket 8. Screws, flat washers, lock washers, and nuts 2002 Nordson Corporation Manual 34-49

10 U7698E Flame Detector Pneumatic Connections See Figure 4. Install a 0.7-bar (10-psi) fixed-pressure regulator for each detector head. 1. Install the regulator(s) (4) on the booth as close as practical to the detector head (2). 2. Install 6-mm air tubing (5) between the regulator input port(s) and the system air supply. 3. Install 6-mm air tubing (3) between the regulator output port(s) and the air shield input port(s). 1 2 3 4 5 1400495A Figure 4 Detector Head Pneumatic Connections 1. Vestibule 4. Regulator 2. Detector head 5. 6-mm air tubing to system air 3. 6-mm air tubing to air shield supply Manual 34-49 2002 Nordson Corporation

U7698E Flame Detector 11 Electrical Connections WARNING: All electrical connections must be made according to local or national electrical codes. Use properly sized wire and approved conduit and fittings. Failure to observe this warning could result in property damage or personal injury. Detector Heads Connect the detector heads to the indicator panel with 7-wire shielded cable, flexible or rigid conduit, and liquid-tight conduit fittings. See Figure 5. 1. Unscrew the upper housing (1) from the lower housing (4). 2. Loosen the mounting screws and unplug the electronics module (3) from the connector board in the upper housing. 3. Remove one of the plugs (8) from the upper housing, and install a 3 / 4 -in. NPT liquid-tight conduit fitting (7) in the open port. 4. Connect conduit (6) to the fitting. Route the cable (5) through the conduit and fitting and into the upper housing. 5. Connect the cable wires to the terminal block (2) and the detector head ground. See Figure 6 for connections. 6. See Figure 5. Set the configuration switches (9). 7. Plug the electronics module back into the connector board. Tighten the electronics board mounting screws. 8. Screw the upper housing on the lower housing. 9. Install a liquid-tight conduit fitting into a knockout in the bottom of the indicator panel and secure the conduit to the fitting. 10. Connect the cable wires to the indicator panel terminal block as shown in Figure 6. 2002 Nordson Corporation Manual 34-49

12 U7698E Flame Detector Detector Heads (contd) 1 2 3 4 5 6 7 8 9 10 11 12 9 on off 1 3 8 ATTENTION 7 5 4 6 2 1400496A Figure 5 Detector Head Electrical Connection 1. Upper housing 4. Lower housing 2. Terminal block 5. Cable 3. Electronics module 6. Conduit 7. Conduit fitting ( 3 / 4 -in. NPT) 8. Plug 9. Configuration switches Interlocks NOTE: All interlock relays are rated for 120 240 Vac, 10A. Connect interlock wiring as shown in Figure 6. 1. Wire the booth interlock terminals so that the booth and application equipment will be shut down when the fire interlock relay opens. 2. Wire the conveyor interlock to the normally open or normally closed relay contacts. 3. If desired, wire a customer-supplied device such as a remote alarm to the customer-use terminals. Use either the normally open or the normally closed contacts. NOTE: Refer to Interlock Relay Contact Conditions for contact operating states Manual 34-49 2002 Nordson Corporation

U7698E Flame Detector 13 Power Supply See Figure 6. Supply 120 240 Vac, 1phase, 50/60 Hz, 2A electrical service to the indicator panel from the booth electrical panel, using 3-wire cable, flexible or rigid conduit, and liquid-tight conduit fittings. Connections must be made so that power is supplied to the indicator panel as long as the booth electrical power is turned on. * Detector Head 1 1 2 6 FIRE 7 FAULT GND GND 9 10 WHT BLK ORG BLU RED GRN Detector Head 2 1 WHT 2 BLK 6 ORG FIRE 7 BLU 9 RED FAULT 10 GRN 120 240VAC,1PH, 50/60 Hz, 2A Service L1 L2 1250 Booth Interlock 1253 1270 1271 Conveyor Interlock 1272 1290 Fire Interlock 1291 (Customer Use) 1292 BLK GRN BLU WHT RED ORG BLK GRN BLU WHT RED ORG FU101 FU101 PE 1250 1253 1270 1271 1272 1290 1291 1292 1230 1231 PE DCCOM 1040 1040 1060 1090 1200 PE DCCOM 1040 1040 1130 1160 1200 1010 120 240VAC, 1PH, 50/60 Hz, 2A to Power Supply 1011 Neutral to Power Supply Green Terminal: Ground Yellow Terminals: Interlocks Green Terminal: Ground Green Terminal: Ground Blue Terminals: DC Circuits *For single detector head systems, jumper from terminals 1040 to 1160 and from terminals 1230 to 1231 1400497A Figure 6 Installation Wiring Diagram 2002 Nordson Corporation Manual 34-49

14 U7698E Flame Detector Operation WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. Startup Normal Mode Fault Mode Turn on power to the powder coating system. The green POWER ON indicator on the indicator panel will light. The FAULT indicators will light then shut off if there are no faults. The red FIRE DETECTED indicator will stay off. In normal operating mode, the green POWER ON indicator is on. amber FAULT and red FIRE DETECTED indicators are off. red LEDs on the detector heads blink once every 5 seconds. interlocked equipment can be started. In fault mode, the amber DET. HEAD FAULT indicator corresponding to the faulted detector head lights. the FAULT DETECTED alarm turns on (continuous tone). all interlocked equipment continues to run. WARNING: Immediately correct any condition that causes a fault or major fault. Do not operate the coating system with the flame detector shut down or bypassed, or with a malfunctioning flame detector component. The system indicates a fault if a detector head loses power, through-the-lens test fails, or sensor or electronics module malfunctions. NOTE: If only one detector head is installed, any fault is treated as a major fault. The booth interlock opens, shutting down the booth and application equipment. When the fault is corrected, the fault indicator turns off and normal mode resumes. Manual 34-49 2002 Nordson Corporation

U7698E Flame Detector 15 Major Fault Mode The system goes into major fault mode when faults are detected in both detector heads, preventing the detection of a fire. WARNING: Immediately correct any condition that causes a fault or major fault. Do not operate the coating system with the flame detector shut down or bypassed, or with a malfunctioning flame detector component. In major fault mode, both amber DET. HEAD FAULT indicators light. the FAULT DETECTED alarm turns on (continuous tone). the booth fire interlock opens, shutting down the booth and application equipment. the conveyor continues to run. NOTE: If only one detector head is installed, any fault is treated as a major fault. When the fault is corrected, the fault indicator(s) and alarm turn off and Normal mode resumes. Fire Mode Reset When a fire is detected, the red FIRE DETECTED indicator turns on. the FIRE DETECTED alarm turns on (fast intermittent tone). booth and conveyor interlock relays open. The booth, application equipment, and conveyor will shut down. fire interlock contact (customer use) changes state. Customer use equipment is either activated or deactivated, depending on use. To reset a detector head after a fault has been corrected, move the DET. HEAD RESET switch toward the appropriate detector head fault indicator, then release it. Through-the-Lens Test The detector heads automatically perform periodic through-the-lens tests to check their operation. If a test fails, the detector head goes into fault mode. Refer to Troubleshooting for diagnostic and correction procedures. 2002 Nordson Corporation Manual 34-49

16 U7698E Flame Detector Optional Test Lamp An optional test lamp can be used to test the ability of the flame detector to detect and warn of a fire in the spray booth. The test lamp produces light with the same frequencies as the light produced by a fire. The test lamp must be placed very close to the detector and waved back and forth slightly to initiate a response. Refer to Parts for the part number. Maintenance WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. WARNING: Keep the detector head lenses clean. Dirty lenses can prevent the detector heads from detecting a fire in the booth. Failure to observe this warning could result in property damage or personal injury. NOTE: Keeping the lenses clean will prevent nuisance fault alarms or shutdowns. A dirty lens can cause a through-the-lens test to fail, triggering a fault. If only one detector head is installed, a fault will shut down the coating system during production. Daily Check the detector head lenses daily. If they are dirty, clean them with an approved low-pressure air gun or an oil- and silicone-free cloth. If necessary, dampen the cloth with ethyl alcohol. Do not use a silicone-based product such as commercial window cleaner to clean the detector head lenses. NOTE: If the detector head lenses are covered with powder overspray, check the air supply to the air shields. Air should be supplied at 0.7 bar (10 psi). Make sure the air shield orifices are not clogged. Periodic Periodically, check all electrical connections. Tighten any loose terminals. Replace any wiring that has worn or damaged insulation. Make sure conduit fittings are tight. Manual 34-49 2002 Nordson Corporation

U7698E Flame Detector 17 Troubleshooting WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. This section contains troubleshooting procedures. These procedures cover only the most common problems that you may encounter. If you cannot solve the problem with the information given here, contact your local Nordson representative for help. WARNING: Hazardous voltages are present inside the indicator panel when booth power is on. Do not touch exposed terminals or wiring when checking voltages. Use insulated tools. Failure to observe could result in severe shock and personal injury. 2002 Nordson Corporation Manual 34-49

18 U7698E Flame Detector Troubleshooting Chart Use the following chart to isolate and correct problems with the flame detector. Problem Possible Cause Corrective Action 1. Detector fault Through-the-lens test failed Make sure the detector lens is clean. If powder is accumulating on the lenses, check the air supply to the air shields. Reset the detector head if the fault continues. 2. No power (green POWER ON indicator on indicator panel is off) Detector head lost power, or sensor or electronics module malfunctioned Blown fuse in indicator panel Faulty wiring to booth electrical panel Indicator panel dc power supply failed Check the red detector head LEDs. When operating normally, the LEDs should blink every 5 seconds. If the LEDs are not blinking, check the wiring between the indicator panel and the detector. There should be 24 Vdc between pins 1 and 2 at the detector. If 24 Vdc is present, make sure the electronics module is securely connected to the connector board and that the connector board harness is connected to the sensor module. If all connections are secure, replace the electronics module. If 24 Vdc is not present, make sure green POWER ON indicator on the indicator panel is on. If the indicator panel has power, repair or replace the wiring between controller and detector. Check the fuses on the terminal block. Replace if necessary with 2A fuses. See Figure 6. Check for the correct voltage at the L1 and L2 terminals on the indicator panel terminal block. If the correct voltage is present, refer to next Possible Cause. If the correct voltage is not present, repair or replace the supply wiring. Check for 24 Vdc at terminals 1040 and DCCOM on the indicator panel terminal block. If 24 Vdc is not present, replace the power supply. Manual 34-49 2002 Nordson Corporation

U7698E Flame Detector 19 Electrical Schematic See Figure 7. L1 L2 PE 100 120 240VAC, 1PH, 50/60HZ, 2A SUPPLY 101 FU101 1010 2A 102 L N PWS102 INPUT 50/60 Hz.68A 100 240VAC 103 104 105 106 107 1040 DET. #1 RESET DET. #2 X SS106 1060 TO LINE 113 1040 1.3A OUTPUT 24VDC V+ V 1011 FU101 2A DCCOM CR105 (14) (13) G LT106 +24VDC POWER SUPPLY 30W, 1.3A OUTPUT BOOTH INTERLOCK RELAY BUFFER 125 POWER ON DETECTOR HEAD RESET 108 109 110 111 DET. HEAD #1 1060 1 DCCOM 2 1200 6 FIRE 1040 7 1090 9 FAULT 1040 10 WHT BLK ORG BLU RED GRN PE DCCOM FROM LINE 120 1090 (14) (13) CR109 FIRE DETECTOR HEAD DETECTOR HEAD #1 FAULT RELAY BUFFER 112,123 112 113 114 CR109 (1) (9) FROM LINE 106 X SS106 1130 1040 * LT112 A DETECTOR HEAD #1 FAULT DETECTOR HEAD RESET 115 116 117 118 119 CR116 (1) (9) DET. HEAD #2 FIRE FAULT 1 2 6 7 9 10 1130 DCCOM 1200 1040 1160 1040 WHT BLK ORG BLU RED GRN PE DCCOM * FROM LINE 121 1160 (14) (13) CR116 A LT119 FIRE DETECTOR HEAD DETECTOR HEAD #2 FAULT RELAY BUFFER 119,123 DETECTOR HEAD #2 FAULT TO LINE 120 TO LINE 120 1400498A Figure 7 Indicator Panel Electrical Schematic (1 of 2) 2002 Nordson Corporation Manual 34-49

20 U7698E Flame Detector Electrical Schematic (contd) FROM LINE 119 FROM LINE 119 CR120 1040 1200 (14) (13) 120 121 122 123 124 125 126 127 CR109 (4) (12) 1040 TO LINE 110 DETECTOR HEAD #1 TO LINE 117 DETECTOR HEAD #2 CR116 1230* (4) (12) 1231 CR105 CR120 CR123 1250 (5) (9) 1251 (4) (12) 1252 (1) (9) 1253 CR120 CR120 1270 (5) (9) 1271 (9) (1) 1272 * 1200 LT121 R ABU122 (14) CR123 ABU124 (13) FIRE DETECTED BUFFER RELAY 125, 127, 127, 129, 129 FIRE DETECTED FIRE DETECTED ALARM BUZZER DUAL DETECTOR FAULT BUFFER RELAY 125 FAULT DETECTED ALARM BUZZER BOOTH INTERLOCK CONVEYOR INTERLOCK 128 129 CR120 CR120 1290 (6) (10) 1291(10) (2) 1292 FIRE INTERLOCK (CUSTOMER USE) * FOR SINGLE DETECTOR HEAD SYSTEMS, JUMPER FROM TERMINALS 1040 TO 1160 AND FROM TERMINALS 1230 TO 1231 Figure 7 Indicator Panel Electrical Schematic (2 of 2) 1400499A Manual 34-49 2002 Nordson Corporation

U7698E Flame Detector 21 Repair WARNING: Allow only qualified personnel to perform the following tasks. Follow the safety instructions in this document and all other related documentation. WARNING: Disconnect and lock out electrical power before servicing. Sensor and Electronics Module Replacement Removing the Old Sensor and Electronics Modules See Figure 8. 1. Turn off power to the detector heads by turning off power to the system. 2. Disconnect the air tubing (1) from the air fitting (2). 3. If desired, loosen the socket-head screws (4) and remove the air shield (3) from the sensor housing (5). 4. Unscrew the sensor housing from the upper housing (8). 5. Disconnect the harness connector (7) from the sensor module (6), and remove the sensor module from the upper housing. 6. Unscrew the lower housing (12) from the upper housing. 7. Loosen the mounting screws and unplug the electronics module (11) from the connector board (not shown) in the upper housing. 2002 Nordson Corporation Manual 34-49

22 U7698E Flame Detector Installing the New Sensor and Electronics Modules 1. Set the configuration switches. See Figure 5 for settings. 2. See Figure 8. Plug the electronics module (10) DIN connector into the socket on the connector board in the upper housing (8). Secure in place by tightening the mounting screws. NOTE: Apply molybdenum disulfide grease to the lower housing and sensor housing threads to prevent galling or binding. 3. Screw the lower housing (11) into the upper housing. 4. Connect the harness connector (7) to the sensor module (6) and place the sensor into the upper housing, making sure it is aligned properly. 5. Install the sensor housing (5) over the sensor. Screw the sensor housing onto the upper housing. 6. If removed, install the air shield (3) onto the sensor housing. Tighten the socket-head screws (4) to secure it to the sensor housing. 7. Connect the air tubing (1) to the air fitting (2). 3 6 2 4 7 ATTENTION 1 5 10 8 11 9 1400500A Figure 8 Sensor and Electronics Module Replacement 1. Air tubing 5. Sensor housing 2. Air fitting 6. Sensor module 3. Air shield 7. Harness connector 4. Socket-head screws 8. Upper housing 9. Terminal block 10. Electronics module 11. Lower housing Manual 34-49 2002 Nordson Corporation

U7698E Flame Detector 23 Parts To order parts, call the Nordson Customer Service Center or your local Nordson representative. Use this five-column parts list, and the accompanying illustration, to describe and locate parts correctly. Using the Illustrated Parts List Numbers in the Item column correspond to numbers that identify parts in illustrations following each parts list. The code NS (not shown) indicates that a listed part is not illustrated. A dash ( ) is used when the part number applies to all parts in the illustration. The number in the Part column is the Nordson Corporation part number. A series of dashes in this column (- - - - - -) means the part cannot be ordered separately. The Description column gives the part name, as well as its dimensions and other characteristics when appropriate. Indentions show the relationships between assemblies, subassemblies, and parts. Item Part Description Quantity Note 0000000 Assembly 1 1 000000 Subassembly 2 A 2 000000 Part 1 If you order the assembly, items 1 and 2 will be included. If you order item 1, item 2 will be included. If you order item 2, you will receive item 2 only. The number in the Quantity column is the quantity required per unit, assembly, or subassembly. The code AR (As Required) is used if the part number is a bulk item ordered in quantities or if the quantity per assembly depends on the product version or model. Letters in the Note column refer to notes at the end of each parts list. Notes contain important information about usage and ordering. Special attention should be given to notes. 2002 Nordson Corporation Manual 34-49

24 U7698E Flame Detector Detector Head See Figure 9. Item Part Description Quantity Note 1 341561 Shield, air, U7698E 1 2 341560 Bracket, mounting, U7698E 1 3 341559 Detector, flame, U7698E 1 4 341565 Module, IR, spare, U7698E 1 5 341562 Module, electronic, U7698E 1 1 4 3 2 5 1400501A Figure 9 Detector Head Parts Manual 34-49 2002 Nordson Corporation

U7698E Flame Detector 25 Indicator Panel See Figure 10. Item Part Description Quantity Note 307445 Panel, indicator 1 1 341361 Power supply, 24 V 1 2 332222 Relay, control, 3-pole 1 3 332223 Relay, control, 2-pole 4 4 939267 Fuse, fast-acting, 250 V, 2 A, 0.25 x 2 1.25 in. 5 332227 Alarm, piezo, fault, continuous 1 6 332226 Alarm, piezo, fire, intermittent 1 3 2 1 CR105 CR109 CR116 CR120 CR123 PWS102 WIREDUCT 6 5 4 1400502A Figure 10 Indicator Panel Parts 2002 Nordson Corporation Manual 34-49

26 U7698E Flame Detector Options Options must be ordered separately. Test Lamp See Figure 11. Part Description Note 341566 Lamp, test, U7698E 1400503A Figure 11 Test Lamp Air Supply Parts Use these parts to supply air to the air shields. Part Description Note 249467 Regulator, fixed, 10 psi 900730 Tubing, 0.25 x 0.040 in., polyurethane, blue 900742 Tubing, 6-mm OD, polyurethane, blue Manual 34-49 2002 Nordson Corporation

U7698E Flame Detector 27 Specifications This section includes specifications for the Nordson U7698E flame detector. Detector Head Terminal Block Connections Table 1 Detector Head Terminal Block Connections Pin Function 1 +24 Vdc 2 dc Common 6 Fire Relay (N.O.) 7 Fire Relay (Com) 9 Fault Relay (N.O.) 10 Fault Relay (Com) Configuration Switch Settings See Figure 12. on off 1400550A Figure 12 Configuration Switch Settings 2002 Nordson Corporation Manual 34-49

28 U7698E Flame Detector Interlock Relay Contact Conditions Table 2 Interlock Relay Contact Conditions Interlock Terminal No Power Normal Operation Booth 1250 1253 Conveyor 1272 1271 1271 1270 Customer 1292 Use 1291 1291 1290 = Closed contact = Open contact NOTE: All relays are rated at 120 240 Vac, 10A. Condition Fault Major Fault Fire Alarm Weight and Dimensions Indicator Panel Height: Width: Depth: 304.8 mm (12 in.) 254 mm (10 in.) 127 mm (5 in.) Detector Head (Including Air Shield) Height: Diameter: 229 mm (9 in.) 114 mm (4.5 in.) Electrical Power Indicator Panel Input voltage: 100 240 Vac, 1 A, 1 phase 50/60 Hz Detector Heads Input voltage: 24 Vdc Manual 34-49 2002 Nordson Corporation