SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof - Suction Type - DA- 800

Similar documents
SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof DA-500

ESD3000 ESD200 Combustible / Toxic Gas Detector

ESD500. ESD500 Combustible / Toxic Gas Detector

FREEDOM SERIES 5000 AND 5600 GAS TRANSMITTERS

Polytron 2. The smart gas detector

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Model D12. Digital Gas Transmitter

Sieger Apex. Flexibility that meets your requirements

SP-220. Features. Combustible handheld gas leakage detector

Toxic Gas Detection. Model F12. Toxic Gas Detection

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS

Contents. Outline of Product. Features of Product. Specifications of Product. Name and central function of section. Illustration of Terminal

compact detector Detection of more than 200 flammable and toxic gases iso 9001:2008

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Equipment. Model R002. Description. SF6 leak detector

ESD3000IR ESD3000IR. Infrared Gas Detector

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

OLC(T) 100 FIXED GAS DETECTOR

Intelligent combined sensor for Air Quality (VOC) + Humidity (rh) + Temperature (T) with analogue outputs, Modbus and LCD display. Features.

Xgard. Fixed detectors For flammable, toxic or oxygen gases

3M Oldham OLCT 100. Description. Fixed Gas Detector

Toxic Smarter Transmitter Instruction Manual

APPLICATION DATA SHEET

Multi-Channel Gas Detector Monitoring Unit GMS

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Electrochemical DrägerSensor Sensors for Fixed Gas Detectors

MDA Scientific Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes

Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

SIL 2. Ultima X Series Gas Monitors CERTIFIED

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

SS-100. Pyrometer. Temperature Range: 800~2400

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

MODEL: Q8 SERIES NON-INTRUSIVE CALIBRATION GAS TRANSMITTER/SENSOR

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

GAS DETECTOR ST400EC PART.NO

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

2-Channel Smoke Detector SD - 110

PRODUCT CATALOG 2016 PT. Victoria Globalindo Teknik PT. Victoria Agfasindo

Self-contained and intrinsically safe wireless stand-alone multi-point gas detector.

Gas Detection For Life

Inc Series Digital Gas Detector/Controller. Operation Manual

Quality. Water. Water Quality. Testing. Testing. Toxic Gas Detection. Toxic Gas. Detection. Air Quality. Monitoring. Monitoring. Monitoring.

Micro III (Models G203, G203S, and G213) Operation Manual

Monitores Personales. Personal Monitor

GasSens. Self Checking Gas Sensors. Modular Gas Detector... Gas & Range Availability

UniSens 2-Wire Gas Transmitter

PolyGard Single Point Controller SPC-X3-34XX for Combustible Gases

Installation and Wiring 1.

FX-SMT Series INSTRUCTION MANUAL P/N THERMO ELECTRON CORPORATION ENVIRONMENTAL INSTRUMENTS 27 FORGE PARKWAY FRANKLIN MASSACHUSETTS 02038

and storage tanks. CO and NOx detection from diesel engine emissions Hospitality Hotels and restaurants LPG detection in commercial kitchens

EC24. Operation Manual. (Type MWG 2411, MWG 2412, MWG 2413 and MWG 2414)

MERIDIAN UNIVERSAL GAS DETECTOR

GAS PLUS ALARM SYSTEM

Combustible Gas Detection and Control System

Version Inc Series Digital Gas Detector/Controller. Operation Manual

MiniCO, MiniH 2 S, MiniOX, MiniOX Remote, MiniCl 2. , and MiniClO 2. Responder Detectors Instruction Manual "! WARNING

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

MICRO III (G202 / G202s / G212) Single Gas Detector

Stand Alone DYNAGARD SP Operation Manual

Low mg/m

EAGLE 2. 6 Channel Capacity. Inlet fitting. Loud buzzer (95dB) IrDA communication port Low flow shutoff and alarm Alarm LED s with wide visibility

Model D12-IR. Digital Gas Transmitter...

The Art of Gas Detection


MICRO IV. Operation Manual. Single Gas Detector

MultiRAE Lite. Wireless Portable Multi-Gas Monitor

UniSens. 2-Wire Gas Transmitter. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

Frequently Asked Questions

Two-Channel Gas Controller

GMA 36 Pro. Operation Manual. Stand Alone Monitor

Meridian. Universal Gas Detector. Description. Features. Minimal drift High specificity Digital ID Broader toxic gas detection

Micro IV. Single Gas Detector. Operations Manual Oak Valley Dr, Ste 20, Ann Arbor MI USA (800) (734)

Instructions TXL Series Oxygen and Toxic Gas Detectors 4/

ALTAIR 5X Multigas Detector Product Specification

GMA 36 Pro. Operation Manual. Stand Alone Monitor

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

WARRANT Y AND LIMITS OF LIABILIT Y Vulcain Inc. warrants to the original purchaser that its product, and the component parts thereof, will be free fro

Industrial Grade Gas Detection Detecting The Difference

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

The Dräger X-am 1700/2000 are a new generation of personal gas detectors.

4P75 CiTipeL Combustible Gas Sensor Part Number: PM

FIXED POINT SINGLE OR DUAL GAS MONITOR WITH DUAL ANALOG OUTPUTS

Oxygen Deficiency Monitor

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Warranty Registration

4P-90 CiTipeL Combustible Gas Sensor Part Number: PM

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

MICROpeL 75 Combustible Gas Sensor Part Number: PM

Micro IV Operation Manual

Product Selection Guide Fixed Gas Detection Systems for Personnel & Equipment Safety

Electron Microscopy Sciences

Fixed Gas & Flame Detection International Product Range Overview

Model Series 700. detcon. Environmentally Bulletproof Gas Detection Sensors. Multi-Layer Surge Protection Water-Proof Corrosion-Proof

PT0E Portable Gas Leak Detector. SP-220 Series. Operating Manual (PT0E-139)

Explosion protection Marijan Gorše, dipl. ing.

Transcription:

SMART Gas Detector/Transmitter(4~20mA) with built-in LCD & explosion proof - Suction Type - DA- 800 C-910C, Bupyeong Woolim Lion s Valley, #425, Cheongcheon-Dong, Bupyeong-Gu, Incheon, Korea TEL: +82-32-623-7507 FAX: +82-32-623-7510 E-mail: sales@gasdna.com Web: www.gasdna.com 1 page

Contents Introduction ------------------------------------ page 3 Features ----------------------------------------- page 3 Specification ----------------------------------- page 4 Terminal ------------------------------------------ page 5 Wiring --------------------------------------------- page 5 User programming ---------------------------- page 6 Dimension --------------------------------------- page 14 2 page

[ Introduction ] DA-800 detects various combustible, toxic and VOC gases leaked from industrial areas and display its density for gas producers, gas users, gas reservoirs, gas by-producers, and so on. It is an indicator and transmitter type gas detector which converts detection signal into a standard current signal and transmit output to external devices. Transmitter of DA-800 displays sensor s current and voltage signal by gas density on LCD, still converts into 4-20mA standard current output signal and transmit to external side. 4-20mA standard current output signal can be transmitted to various controller such as Gas leakage alarm system (GMS1000, GMS2000) PLC, DDC, MMR to build a integrated or individual gas monitoring system. [Features] Built-in micro processor realizes various artificial intelligent functions which result in more convenient, more accurate, and more efficient gas detection environment. Built-in HD(high dissolution) A/D converter for accurate output signal. LOW/HIGH 2 step relay contacts (AL1/AL2) enable to interlock with a various external devices like FAN. 4-20mA output enables stable and long distance (maximum 2.5km) signal transmission. User programmable Menu offers to set user s own operating functions. 3 page

[Specification] Segment DA-800 Gas sampling Density display Suction type LCD Display - PPM, %LEL, % (set by user) Input power DC 20~30V Structure Target gas Detection principle Suction flow rate Suction distance Measurement range Accuracy Response time Sensor calibration User programming Wiring Output signal Alarm output Operation Temperature Operation humidity Wire conduit Housing material Mounting Explosion proof Toxic, Combustible, O2, VOC(PID) (select) Catalytic, Electro-Chemical, VOC(PID),NDIR (select) 0 ~ 1000ml/ min Within 100m Please refer to the target gas list (page 16) ±2%/Full Scale Within 20 seconds, 90% / full scale AUTO-CALIBRATION with Magnetic Switch Calibration density & Measurement range CVVS & CVVSB 1.25sq*3wire 4-20mA DC/F.S // RS-485(MODBUS-RTU) 2 Step (HIGH/LOW) Alarm RELAY CONTACT -10 ~ 50 5 ~ 95%RH (Non-Condensing) 1/2 or 3/4 PF,NPT Cast Aluminum Alloy Wall or Pipe Station 4 page

[Terminal] [ WIRING ] 5 page

[ User programming] CAL MODE DOWN UP O2 [measuring mode] 20.0 % (pressing 3 sec) ALARM MODE DOWN UP OPTION MODE <1> CAL MODE - Adjust zero calibration & span calibration for sensor calibration <2> ALARM MODE - Adjust setting value of alarm type, alarm 1, & alarm 2. <3> OPTION MODE - Adjust the other parameters 6 page

[1] CAL MODE CAL MODE CAL [ZERO] CAL [ZERO],[SPAN] CAL ZERO 0.0 % SPAN ADJ 20.9 % FULL SCALE 20% - 100% ADJ CAL ZERO CAL ZERO CAL SPAN [FAIL] [OK] 20.9% CAL SPAN [FAIL] CAL SPAN [OK] (1.1) Zero calibration 1 At CAL [ZERO], please press MODE key to start zero calibration. And then, CAL ZERO <0.0%> appears on the LCD. 2 Please infuse the clean air or 100% nitrogen gas at 500ml/min flow rate until the displayed value is stabilized. 3 Please press MODE key to complete the zero calibration. And then, CAL ZERO [OK] appears on the screen. If the zero calibration is not successful, CAL ZERO [FAIL] will be appeared on the LCD during 2 seconds. (1.2) Span calibration 1 At CAL [SPAN], please press MODE key to start span calibration. And then, SPAN ADJ <20.9%> appears on the LCD. 2 Please press UP, DOWN key to input the standard gas value. 3 Please press MODE key to confirm it. And then, CAL SPAN [20.9%] appears on the LCD. 4 Please infuse the standard gas at 500ml / min flow rate during 1 minute. 5 Please infuse the standard gas during one(1) minute. And then, please wait until the displayed value gets stabilized. 6 When the displayed vale has been stabilized, please press MODE key. And then, CAL SPAN [OK] appears on the LCD. If the calibration is not successful, CAL SPAN [FAIL] will be appeared on the 7 page

LCD during 2 seconds. [2] ALARM MODE ALARM MODE AL TYPE [L&LL] AL TYPE [L&LL][L&H][H&HH] AL RESET [AUTO] AL RESET AUTO,MANUAL HI SCALE 20.9 % HI SCALE 0 ~ 9999 ALARM 1 10.0 % ALARM 1 0 ~ 9999 ALARM 2 5.0 % ALARM 2 0 ~ 9999 MOTOR 100 % MOTOR 0 ~ 100% 8 page

(2.1) AL TYPE (Select alarm type) - It has Four(4) alarm types: L&L, L&H, H&L, and H&H - You can use two alarm relay relay 1 & relay 2. (ex) If you set AL TYPE to H&L: Relay 1- set high: when the measured value is higher than set value, alarm on. Relay 2 -set low: when the measured value is lower than set value, alarm on. (2.2) AL RESET - The method how to control ALARM Relay. - Select AUTO MANUAL <1> AUTO: The relay contact & Alarm LED releases according to set value automatically regardless of reset switch <2> MANUAL: Only when you press reset switch, the relay contact & LED releases. (2.3) HI SCALE - Set 4 ~ 20mA output signal for full scale. (ex) If you set SCALE to 100, 4mA output signal displays 0 and 20mA output signal displays 100. (2.4) ALARM 1 - According to AL TYPE, alarm #1 on. (2.5) ALARM 2 - According to AL TYPE, alarm #2 on. (2.6) MOTOR (Suction pump flow rate control) - Set the flow rate from 0 to 100ml / min. - 9 page

[3] OPTION MODE OPTION MODE PassWord 0000 PassWord( input 507) 0 ~ 9999 DP POINT 000.0 DP POINT 0.000 ~ 0000. UNIT [PPM] UNIT PPM,%,%LEL GAS TYPE O2 GAS TYPE [O2.etc] OFFSET 000.0 OFFSET -99 ~ 99 INITTIME 30 INITTIME 0 ~ 99 10 page

AL BAND 01 AL BAND 0 ~ 99 AL TIME 05 AL TIME 0 ~ 99 BAUDRATE 9600BPS BAUDRATE 4800,9600,19200,38400 56700BPS ADDRESS 01 ADDRESS 0 ~ 99 RELAY 1 OFF RELAY 1 OFF,ON RELAY 2 OFF RELAY 2 OFF,ON RELAY TR OFF RELAY TR OFF,ON ma OUT 4mA ma OUT 4mA,20mA (***) OPTION MODE is scarcely used. Please press password 507 to enter the OPTION MODE 11 page

(3.1) DP POINT (Set decimal point of density values) - Change decimal point according to the measurement range. (3.2) UNIT(Select density unit) - 3 options: %LEL, PPM, %. (3.2) GAS TYPE(Display measuring gas) - 02, HCL, and so on. (3.3) OFFSET(Compensation of measured value) - Compensate the measured value. (ex) OFFSET: If it sets +5, When the measured value is 5, it have to display -5. But it displays 0 after compensation of +5. (3.4) INITTIME(Initialization time) - After certain time from power on, sensor can provide stable output. (3.5) AL-BAND(ALARM DEAD BAND) Relay output usually repeats on/off around the alarm set value and it makes trouble. D-BAND function gives hysteresis value on the alarm set value to remove this kind of trouble. (ex1) If ALARM 1 sets 20, ALARM TYPE sets H&H & D-BAND sets 3 When value displays higher than 20, alarm on lower than 17, alarm off. (ex2) If ALARM 1 sets 20, ALARM TYPE sets H&L & AL-BAND sets 3 When value displays lower than 20, alarm on higher than 23, alarm off. (3.6) AL TIME (ALARM DELAY TIME) This function is to prevent the normal operation of sensor against any momentary malfunctions affected by outside impact or noise. (ex) When alarm value sets 50 & AL TIME sets 5. Only when the measured value keeps higher than alarm set value during longer than 5 seconds, alarm on. (3.7) BAUDRATE - Set RS-485 baud rate. (3.8) ADDRESS - Set RS-485 address. 12 page

(3.9) RELAY 1 [OFF] - Self test mode to diagnose ALARM-1 relay output. (3.10) RELAY 2 [OFF] - Self test mode to diagnose ALARM-2 relay output. (3.11) RELAY TR [OFF] - Self test mode to diagnose ALARM TROBLE relay output. (3.12) ma OUT - Self test mode to diagnose analogue signal output. - 13 page

[ Dimension ] 14 page

GAS IN GAS OUT(1/4 (1/4 PT) 1/2 PF 15 page

DA-800 Toxic gas list Target Gas Formula Measuring Range Code Number Acetaldehyde CH 3CHO 0~500 ppm DA-800-CH 3CHO Ammonia NH 3 0~100 ppm DA-800-NH 3 Arsine AsH 3 0~1.00 ppm DA-800-AsH 3 Arsenic Trichloride AsCI 3 0~1.00 ppm DA-800-AsCI 3 Arsenic Trifluoride AsF 3 0~10.0 ppm DA-800-AsF 3 Arsenic AsF 5 0~10.0 ppm DA-800-AsF 5 Pentafluoride Boron Trichloride BCI 3 0~15.0 ppm DA-800-BCI 3 Boron Tribromine BBr 3 0~15.0 ppm DA-800-BBr 3 Boron Trifluoride BF 3 0~10.0 ppm DA-800-BF 3 Butanethiol C 4H 9SH 0~10.0 ppm DA-800-C 4H 9SH Carbonyl Fluoride COF 2 0~10.0 ppm DA-800-COF 2 Carbon Dioxide CO 2 0~5000 ppm DA-800-LCO 2 Carbon Dioxide CO 2 0~5.00 % DA-800-MCO 2 Carbon Dioxide CO 2 0~100 % DA-800-HCO 2 Carbon Monoxide CO 0~500 ppm DA-800-CO Carbon CCI 4 0~30.0 ppm DA-800-CCI 4 Tetrachloride Chlorine CI 2 0~10.0 ppm DA-800-CI 2 Chlorine Dioxide CLO 2 0~2.00 ppm DA-800-CLO 2 Chlorine Trifluoride CLF 3 0~2.00 ppm DA-800-CLF 3 Diborane B 2H 6 0~1.00 ppm DA-800-B 2H 6 Dichlorosilane SiH 4CI 2 0~10.0 ppm DA-800-SiH 4CI 2 Disulfur S 2F 10 0~10.0 ppm DA-800-S 2F 10 Decafluoride Disulfur Dichloride S 2CI 2 0~10.0 ppm DA-800-S 2CI 2 Flourine F 2 0~10.0 ppm DA-800-F 2 Formic Acid HCOOH 0~500 ppm DA-800-HCOOH Germane GeH 4 0~1.00 ppm DA-800-GeH 4 Germanium GeCI 4 0~10.0 ppm DA-800-GeCI 4 Chloride Hydrazine N 2H 4 0~10.0 ppm DA-800-N 2H 4 Hydrogen H 2 0~2000 ppm DA-800-H 2 Hydrogen Bromide HBr 0~10.0 ppm DA-800-HBr 16 page

Hydrogen Chloride HCI 0~10.0 ppm DA-800-HCI Hydrogen Cyanide HCN 0~50.0 ppm DA-800-HCN Hydrogen Fluoride HF 0~10.0 ppm DA-800-HF Hydrogen Sulfide H 2S 0~100 ppm DA-800-H 2S Iodine 2 l 2 0~10.0 ppm DA-800-l 2 Isopropanol 2 (CH 3) 2 CHOH 0~500 ppm DA-800-(CH 3) 2 CHOH Methanol 2 CH 3OH 0~500 ppm DA-800-CH 3OH Nitric Oxide NO 0~100 ppm DA-800-NO Nitrogen Dioxide No 2 0~20.0 ppm DA-800-No 2 Nitrogen Trifuoride NF 3 0~30.0 ppm DA-800-NF 3 Oxygen O 2 0~30 % vol DA-800-O 2 Ozone O 3 0~1.00 ppm DA-800-O 3 Phosgene COCI 2 0~5.00 ppm DA-800-COCI 2 Phosphine PH 3 0~1.00 ppm DA-800-PH 3 Phosphorus PCI 3 0~15.0 ppm DA-800-PCI 3 Trichloride Phosphorous PCI 5 0~15.0 ppm DA-800-PCI 5 Phosphoryl POCI 3 0~10.0 ppm DA-800-POCI 3 Chloride Silane SiH 4 0~20.0 ppm DA-800-SiH 4 Silicon SiCI 4 0~10.0 ppm DA-800-SiCI 4 Tetrachloride Stibin 2 SbH 3 0~1.00 ppm DA-800-SbH 3 Sulfur Dioxide SO 2 0~20.0 ppm DA-800-SO 2 Sulfuryl Fluoride 2 SO 2F 2 0~10.0 ppm DA-800-SO 2F 2 Sulfur Tetrafluoride SF 4 0~9.00 ppm DA-800-SF 4 Trichlorosilane SiHCI 3 0~15.0 ppm DA-800-SiHCI 3 Thiophene C 4H 4S 0~50.0 ppm DA-800-C 4H 4S Tin Tetrabromide SnBr 4 0~10.0 ppm DA-800-SnBr 4 Tin Tetrachloride SnCI 4 0~30.0 ppm DA-800-SnCI 4 Tin Tetrafluoride SnF 4 0~10.0 ppm DA-800-SnF 4 Titanium TiCl 4 0~10.0 ppm DA-800-TiCl 4 Tetrachloride Trichlorosilane SiHCl 3 0~10.0 ppm DA-800-SiHCl 3 Trichlortriazine C 3Cl 3N 3 0~10.0 ppm DA-800-C 3Cl 3N 3 Trifluorotriazine C 3F 3N 3 0~10.0 ppm DA-800-C 3F 3N 3 17 page

DA-800 Combustible gas list Target gas Formula Explosion limit (%VOL) Acetaldehyde CH 3CHO 4 Acetic acid CH 3COOH 4 Acetone CH 3COCH 3 2.5 Acetylene C 2H 2 2.5 Bezene C 6H 6 1.5 Butane C 4H 10 1.86 Chloro benzene C 6H 5CI 1.3 Cyclohexane C 6H 12 1.3 Di-Methylethar CH 3OCH 3 2 Ethane C 2H 6 3.22 Ethanol CH 3CH 2OH 3.6 Ethylene C 2H 4 2.75 Ethylene glycol (EG) HOCH 2CH 2OH 3.2 Ethylene oxide (EO) C 2H 4O 3.0 Formic acid CH 2O 2 16.9 Gasoline 1.4 Heptane CH 3(CH 2) 5CH 3 1.05 Hydrogen H 2 4 Iso-butane i-c 4H 10 1.8 Iso-propyl alcohol (CH 3) 2CHOH 2 Methane CH 4 5 Methyl alcohol CH 4O 7.3 Methyl bromide CH 3Br 1 Naphthalene C 10H 8 0.9 Octane CH 3(CH 2) 6CH 3 1 Pentane CH 3CH 2CH 2CH 2CH 3 1.5 Phenol C 6H 5OH 1.3 Propane C 3H 8 2.1 Propylene C 3H 6 2 Propylene oxide (PO) C 3H 6O 2.3 Thinners 1 Toluene C 7H 8 1.2 Vinyl acetate (VAM) CH 2=CHOCOCH 3 2.6 Vinyl chloride CH 2=CHCI 3.6 18 page

Xylene C 8H 10=C 6H 4[CH 3] 2 1.1 *For other gases(unlisted gases), Please contact us. 19 page