PROGRAMMABLE THERMOSTAT FOR ELECTRICAL FLOOR HEATING INSTALLATION INSTRUCTION

Similar documents
GREEN LEAF PROGRAMMABLE THERMOSTAT FOR ELECTRICAL FLOOR HEATING INSTALLATION INSTRUCTIONS. EN-RaychemGreenLeaf-IM-EU0209 THERMAL BUILDING SOLUTIONS

PROGRAMMABLE THERMOSTAT

DEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive

T-32-TS Touchscreen Thermostat. Installation Manual

Installation Guide. DEVIreg Smart. Intelligent Electronic Timer Thermostat with Wi-Fi connectivity and App control.

TOUCHSCREEN THERMOSTAT

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

Installation Guide. DEVIreg Smart. Intelligent Electronic Timer Thermostat with Wi-Fi connectivity and App control.

WT01 INSTRUCTIONS. English. GREEN COMFORT Maximum comfort with low energy consumption /15 (ALA) 2015 OJ Electronics A/S

RET2000 MD Electronic digital thermostat with LCD, delayed start. Danfoss Heating. Installation Guide

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 550. Electronic Intelligent Thermostat.

MAKING MODERN LIVING POSSIBLE. Danfoss Heating. RET2000 B/M/MS Electronic digital thermostat with LCD Installation Guide

installation guide installation guide electronic intelligent timer thermostat

Installation Guide. DEVIreg Touch. Electronic Intelligent Timer Thermostat.

DigiTrace NGC-20. Local Control Central Monitoring

INITIALIZATION / INSTALLATION

ETN24-P/PD-FC-SUPER2. Owner's Manual - Installation and Operating Instructions

EFET 535. Installation Manual INT INT

AC500T, AC1000T, AC1500T, AC2000T

FIL-SPL Flow-through heater for central heating USER MANUAL

Comfort System T-21-P Touchscreen Thermostat Installation Manual

AUS. Devireg TM 535 Installation and user manual

Installation Guide. DEVIreg 534. Electronic Thermostat.

EB-Therm 300 E / SSTL MONTERINGSANVISNING / INSTALLATION INSTRUCTIONS LEGGEANVISNING / ASSENNUSOHJEET

Instruction FH-CWP Thermostat

GreenCon On/Off Room Thermostat

Weekly thermostat for boilers Galan - regulator for management of heating elements and circuit SolarSentinel-DBTW Users guide.

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

Easy-Stat. Wireless Programmable Room Thermostat Pt No

User Manual 120/240/300 Outdoor Motion Detector

Installation Guide. DEVIreg 233. Electronic Thermostat.

Installation Guide. DEVIreg 535. Electronic Thermostat.

HTC-915-CONT. Heat-Trace Control system

Model: Slimline-N. 1 Slimline Series

5230IG. Thermotouch 3.2aP Wireless Heating Thermostat

GreenCon On/Off Room Thermostat

Type UDG, UCG, UTN, USG

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Programmable Thermostat

: PRT / PRT PRT / PRT-N1

Smart Temp. Model

Hygienic, tough, versatile.

Underfloor Heating Programmable Thermostat

Photoelectric sensors W27-3, Photoelectric proximity sensor, Background suppression

Installation Guide DEVIlink FT Floor thermostat

ABLOY DA460 SWING DOOR OPERATOR. Installation and commissioning manual

Semi flush-mount room thermostats

Model: Available in: Sapphire Black and Glacier White. 1 Series

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

ACS-30-EU-VIA-DU-20-MOD

Installation Guide. DEVIreg 330 (-10 to+10 C) Electronic Thermostat.

5245 / Thermotouch 4.3dC. Dual Control Thermostat. Installation & User Guide

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

MAKING MODERN LIVING POSSIBLE. Installation Guide. ECtemp 130. Electronic Thermostat.

SMART 1000 Touchscreen Thermostat Installation Manual

Thank you for buying a DEVI product. With this purchase you have obtained a product of the highest quality, designed to give long lasting comfort at

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

Model: Available in : Sapphire Black and Glacier White. 1 Series

Smart Temp. ApolloP/n Installation Manual. Version 1.0

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

Model : PRT-EN Model: PRT-EN1

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

CET2000B-RF + RX1-S + CS2

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

LCF Touch. Electronic Fan Coil Thermostat with Touch Display (Flush mounting) Datasheet. Application. Security Advice Caution.

ETN-24-HC21-PROG Econo-Vent

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

Basic Plus2 Room Thermostats Floor Heating

Programmable Towel Radiator Manual

Panel Convector Heater User Instructions

LCF Touch Modbus Datasheet Application Security Advice Caution

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

7-Day. Digital Thermostat. residential. & 2-cool

Model: Slimline-RF. 1 Slimline Series

Installation and user manual

LCF Touch (from firmware version 1.7)

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

Operation Manual NOVA LIVE S

P200 Programmable Thermostat Installation Instructions & User Guide. For Installation Help. White-Rodgers.com

Color Touch Heating Thermostat WARMTEC WTS

Photoelectric sensors W27-3, Photoelectric proximity sensor, Background suppression

DEVIreg 330 (+5 to +45 C) Electronic Thermostat

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

TPOne-S. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

MAKING MODERN LIVING POSSIBLE INT INT EFIT 550. User Guide and Installation Manual. Danfoss Heating

Touch Screen Thermostats. Features. Accuracy +/-1 C. Power supply 220 Vac. Consumption < 1.5 W. Timing error < 1% Ordering TST 8A TST 8B TST 8C

Please read this manual carefully before installation and use.

ELECTRIC BOILERS FOR CENTRAL HEATING

Model: Edge-HC. 1 edge-hc

Safety & Installation Instructions

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

INSTALLATION & USER MANUAL

INFRARED PANEL HEATER

ECW-GF, ECW-GF-DP DIGITAL ELECTRONIC CONTROLLERS AND REMOTE DISPLAY PANEL PRODUCT OVERVIEW

installation guide digital timer thermostat

Model: RT310. Installation Manual

T60xDFH-4 and T60xDFH-4+PIR Series Thermostat Controllers with Dehumidification and Occupancy Sensing Capability

Danfoss Link FT Floor Thermostat

Transcription:

GREEN-LEAF-EU PROGRAMMABLE THERMOSTAT FOR ELECTRICAL FLOOR HEATING INSTALLATION INSTRUCTION Full EN Manual pentairthermal.com/manuals/ THERMAL BUILDING SOLUTIONS EN-RaychemGreenLeafEU-IM-EU0637 Rev0

CONTENTS 1. DESCRIPTION...3 2. MOUNTING AND INSTALLATION...4 Mounting the Thermostat... 4 3. USING THE THERMOSTAT...9 The Display... 9 Display in manual on/off programme... 9 Display in timer programme... 10 The manual on/off programme... 11 The timer programme... 12 4. SETTING THE CLOCK... 14 5. PROGRAMMING THE TIMER PROGRAMME... 15 6. INSTALLER MENU... 17 7. TROUBLESHOOTING... 21 8. TECHNICAL SPECIFICATION... 22 ATTENTION This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision. 2

1. DESCRIPTION The Raychem Green Leaf Thermostat is a Programmable Thermostat designed for Electrical Floor Heating. The thermostat is designed to control your Electrical Floor Heating in order to give you the best possible comfort and the lowest possible energy usage. The Thermostat can work in 3 different temperature sensing modes: Floor Sensing mode Room Sensing mode Room Sensing mode with floor temperature limiter The Thermostat has 2 programmes to choose from: Manual ON/OFF (Constant Single temperature) Timer programme (4 timer events/day) To change from one programme to the other, just touch the intelligent leaf button. 3

2. MOUNTING AND INSTALLATION Mounting the Thermostat The installation of the Green Leaf must be performed by a qualified installer. The Green Leaf is a thermostat with protection class IP20, make sure to comply with all local regulations when installing the thermostat. Green Leaf is intended for flush mounting in a wall box. It should be positioned approximately 1.5 meters above the floor, protected from direct sunlight and draughts. All electrical conduits passing into the wall box that contain cables must also be sealed to protect the thermostat against draughts, e.g. with a piece of insulation in the conduit outlet. Step 1: Switch off the power supply Step 2: Detach the metallic support from the Thermostat using a screwdriver Step 3: Screw the metallic support frame to the in-wall box 4

Step 4: Install the floor sensor (mandatory for floor sensing mode or room sensing mode with floor temperature limiter). The floor sensor should be installed in a separate flexible conduit all the way to the end, covering the end of the sensor, for easy replacement and to avoid possible signal disturbance on the sensor. For best control performance, position the floor sensor between two heating cables as close as possible to the top floor surface. Do not position the floor sensor tip closer than 3 cm to the heating cable. The floor sensor cable can be extended up to 100 m with a separate standard installation cable 2 x 1.5 mm 2 (230VAC). Step 5: Connect the electrical power supply, the sensor and the cold lead of the electrical floor heating system to the Green Leaf according to the electrical diagram. If you connect heating cables exceeding 13A for constant wattage or 10A for self-regulating cables you must use a contactor with an integrated suppression device. For the earth connection of the floor heating, you must use a separate earth terminal connection block. 5

NTC Floor Sensor PE Heating cable 230 VAC Max. 13A* L Power supply 230 VAC L N NTC Floor Sensor Power supply 230 VAC L N Power supply heating cables L1 L2 L3 N PE 10KΩ PE 10KΩ A2 1 3 5 PE N K1 A1 PE 2 4 6 L L L N N N SENSOR SENSOR K1: contactor with integrated suppression device Direct connection - e.g. single heating circuit * Max 13A for constant wattage cable, Max 10A for self-regulating cables Connection via contactor - e.g. 3 heating circuits Do not use contactor without suppression device. Step 6: Click the Green Leaf into the metallic support frame. Step 7: Switch on the power again 6

Product specific information The thermostat is compatible with CeraPro, T2QuickNet, T2Blue, T2Green and T2Red heating solutions. T2QuickNet T2QuickNet heating mats are approved with the Green Leaf thermostat working in floor sensor mode. Be aware that the floor sensor must be installed and activated for any installation with T2QuickNet. T2Red Self-regulating heating cables have an inrush current when the floor is cold. In order to guarantee the life time of the thermostat, the maximum load of the self-regulating application in nominal conditions is limited to 10A. A 13A self-regulating load will reduce the life time of the relay contacts. 3.USING THE THERMOSTAT The Display Display in manual on/off programme The following icons are visible in the Manual ON/OFF: Active sensor display Floor sensing mode ( ) Room Sensing mode ( ) Room Sensing mode with Floor temperature limiter ( ) 7

Heating display The heating display is flashing when the heating is on. Temperature The temperature on the display depends on the selected sensing mode. Floor sensing mode => Actual floor temperature on the display Room sensing mode => Actual room temperature on the display Room sensing with floor temperature limiter mode => Actual room temperature on the display Remark: When pushing on the or button, the set point temperature appears on the display blinking for 5 seconds Installer Menu Touch the M button for 5 seconds to enter the Installer Menu Display in timer programme The following icons are visible in the Timer Programme: Time and day The actual day is displayed on the screen with the 3 letters (MON-TUE-WED-THU-FRI-SAT-SUN). The time can be set in 24H or 12AM/PM mode (see INSTALLER MENU). 8

4 Event display The 4 events are displayed with the symbols: Event 1 Event 2 Event 3 Event 4 The manual on/off programme When switching on the thermostat for the first time (touching the Green Leaf button for 2 seconds), it will start in MANUAL ON/OFF programme using the floor sensing mode as a standard (see INSTALLER MENU to change the sensing mode). You will see the following screen: Touch or to show the set point temperature. It will blink for 5 seconds. 1. Touch to decrease the temperature. 2. Touch to decrease the temperature. To switch from Manual ON/OFF to Timer Programme, touch the button once. To switch off the thermostat, touch the button for 2 seconds. 9

The timer programme The Green Leaf can be programmed with 4 events per day. Different temperatures can be maintained for each event of the day. The days can be programmed independently or per cluster of days. The default Timer Programme is shown on the graph below. You can easily adapt the programme to your needs (see PROGRAMMING THE TIMER PROGRAMME) 25 MON-TUE-WED-THU-FRI 20 15 10 5 16 23 23 16 16 0 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 20:00 21:00 22:00 23:00 25 20 SAT-SUN 15 10 16 23 5 0 0:00 1:00 2:00 3:00 4:00 5:00 6:00 7:00 8:00 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00 18:00 19:00 20:00 21:00 22:00 23:00 Touch the button to set the clock and day of the week Touch the button for 3 seconds to program the timer programme (see page 14 for more details). Touch the button for 5 seconds to enter the Installer Menu Touch the button to switch from Timer to Manual ON/OFF mode Touch the button for 2 seconds to put the Thermostat into OFF (standby) mode Touch or to show the set point temperature. It will blink for 5 seconds 1. Touch to decrease the temperature. 2. Touch to decrease the temperature. Remark: The adapted temperature is valid until the next timer Event. 10

4. SETTING THE CLOCK Touch the button to set the clock and day of the week Touch or to change the hours Touch the button to validate Touch or to change the minutes Touch the button to validate Touch or to change the day of the week Touch the button to validate Remark: In case of battery drainage after long period of power failure, you might have to re-programme the clock 5. PROGRAMMING THE TIMER PROGRAMME Touch the button for 3 seconds to program the Timer Programme Touch or to choose the day (or the sequence of days) you want to program Touch the button to validate Day Sequences are: MON TUE WED THU FRI SAT SUN MON TUE WED THU FRI SAT SUN MON TUE WED THU FRI SAT SUN 11

For Event 1 Touch or to change hours of Event 1 Touch the button to validate Touch or to change the minutes of Event 1 Touch the button to validate Touch or to change the temperature for Event 1 Touch the clock button to validate For Event 2, 3 and 4 Repeat the actions for event 1 for the Events 2, 3 and 4 Touch the button, at any time during the programming, to save your changes and return to the Timer Programme. If needed, you can repeat the complete procedure to program other days or sequences of days. 12

6. INSTALLER MENU Touch the button for 5 seconds to enter the installer Menu # Description Range Default setting 1 Sensing mode selection Floor sensing mode Room sensing mode Room sensing mode with floor temperature limiter 2 12 vs 24 hours display 12 / 24 24 3 Motion sensor. When getting close to the thermostat (5cm range) the display lights up automatically 4 Offset for floor sensor calibration ON / OF Floor Sensing mode ON Offset of 0.. 10 C 4 C 5 Room sensor calibration Measured sensor temperature +/- 5 C 6 Minimum temperature Floor sensing mode: 5.. 15 C Measured sensor temperature 5 C set point for the Floor Sensor Room sensing mode: OF Room sensing mode with floor temperature limiter: OF OF OF 13

# Description Range Default setting 7 Maximum temperature set point for the Floor Sensor 8 Minimum temperature set point for the Room Sensor 9 Maximum temperature set point for the Room Sensor Floor sensing mode: Minimum temperature set point floor sensor (installer menu 6) +5 C.. 35 C Room sensing mode: OF Room sensing mode with floor temperature limiter: 10.. 35 C Floor sensing mode: OF Room sensing mode: 5.. 15 C Room sensing mode with floor temperature limiter: 5.. 15 C Floor sensing mode: OF Room sensing mode: Minimum temperature set point room sensor (installer menu 8) +5 C.. 40 C Room sensing mode with floor temperature limiter: Minimum temperature set point room sensor (installer menu 8) +5 C.. 40 C 35 C OF 27 C OF 5 C 5 C OF 40 C 40 C 10 Adjustable hysteresis 0.5.. 2.0 C 1.0 C 14

Floor sensor calibration The temperature of the floor surface can differ from the temperature measured by the floor sensor due to the floor construction, the floor type and the position of the floor sensor. In order to calibrate your thermostat to this difference you can use the floor sensor calibration OFFSET in installer Menu 4. After the temperature on the floor is stabilized, place a thermometer on the floor surface in order to sense the real temperature on the surface (Tsurface). Read the floor sensor temperature (Tsensor) on the thermostat and adjust the OFFSET accordingly to the formula: OFFSET = Tsensor - Tsurface Tsurface Tsensor Room sensor calibration If the value measured by the room sensor in the thermostat differs from the real room temperature, it is possible to calibrate the room sensor using the installer Menu 5. After the temperature in the room is stabilized, place a thermometer close to the wall in order to sense the real room temperature. If this value differs from the one shown by the thermostat, adjust Menu 5 using the or the until the thermostat shows the same value as the reference thermometer. 15

7. TROUBLESHOOTING In the event of damage or malfunction of one of the temperature sensors, the heating output cuts off (fail safe) and an error code is displayed. Error Code ER1 ER2 ER3 ER4 ER5 Description Short circuit on floor sensor Open circuit on floor sensor / Missing floor sensor Short circuit on room sensor Open circuit on room sensor Check sensing mode The floor sensor can be replaced by a new. In the event of malfunction of the room sensor, the entire thermostat must be replaced (Error 3 or Error 4). Error 5 occurs if the thermostat is set in Room Sensing Mode and the floor sensor is installed. To resolve the error change the sensing mode in Floor sensing or Room sensing with floor temperature limiter. Otherwise, remove the floor sensor to work in room sensing mode. The floor sensor has got the following temperature/resistance values: Temperature Resistance 15 C 15.8 kω 20 C 12.5 kω 25 C 10.0 kω 30 C 8.0 kω 35 C 6.5 kω 16

8. TECHNICAL SPECIFICATION Supply voltage 230VAC, +10%, 15%, 50Hz Power consumption (Stand-by) 3 VA Relay output 230V, maximum 13A resistive load (max. 3000W) Ambient temperature operation 0.. 40 C, 5-95% RH (non condensing) Ambient temperature transport 10.. +60 C Temperature range, floor sensor +5.. +35 C Temperature range, room sensor +5.. +40 C Switching hysteresis 1 C (Factory settings adjustable between 0.5-2.0 C) Control modes Floor sensing Room sensing Room sensing with floor temperature limiter Temperature control Manual ON/OFF Timer programme Protection class IP 20 Terminals Max. 2,5 mm² Floor sensor with 3 m cable NTC, 10KΩ / 25 C Maximum length of floor sensor Cable 100 m, 2 x 1,5 mm² (230VAC cable type) Approvals Type of action 1.B. (39)* Control pollution degree 2 (49)* Rated impulse voltage 4kV (75)* Temperature for the ball pressure test 125 C (77)* SELV limits realized 22 VDC (86)* * According to the EN 60730-1 table 1 Our products satisfy the requirements of the relevant European Directives. 17

18

Dimensions 41.0 86.3 86.3 16.5 86.3 79.8 60.0 48.0 49.0 19

BELGIË / BELGIQUE Tel. +32 16 21 35 02 Fax +32 16 21 36 04 salesbelux@pentair.com BULGARIA Tel./fax +359 56 86 68 86 fax +359 56 86 68 86 salesee@pentair.com ČESKÁ REPUBLIKA Tel. +420 241 009 215 Fax +420 241 009 219 czechinfo@pentair.com DANMARK Tel. +45 70 11 04 00 Fax +45 70 11 04 01 salesdk@pentair.com DEUTSCHLAND Tel. 0800 1818205 Fax 0800 1818204 salesde@pentair.com ESPAÑA Tel. +34 902 125 307 Fax +34 91 640 29 90 ptm-sales-es@pentair.com FRANCE Tél. 0800 906045 Fax 0800 906003 salesfr@pentair.com HRVATSKA Tel. +385 1 605 01 88 Fax +385 1 605 01 88 salesee@pentair.com ITALIA Tel. +39 02 577 61 51 Fax +39 02 577 61 55 28 salesit@pentair.com LIETUVA/LATVIJA/EESTI Tel. +370 5 2136633 Fax +370 5 2330084 info.baltic@pentair.com MAGYARORSZÁG Tel. +36 1 253 7617 Fax +36 1 253 7618 saleshu@pentair.com NEDERLAND Tel. 0800 0224978 Fax 0800 0224993 salesnl@pentair.com NORGE Tel. +47 66 81 79 90 Fax +47 66 80 83 92 salesno@pentair.com ÖSTERREICH Tel. 0800 297410 Fax 0800 297409 info-ptm-at@pentair.com POLSKA Tel. +48 22 331 29 50 Fax +48 22 331 29 51 salespl@pentair.com REPUBLIC OF KAZAKHSTAN Tel. +7 495 926 18 85 Fax +7 495 926 18 86 saleskz@pentair.com РОССИЯ Тел. +7 495 926 18 85 Факс +7 495 926 18 86 salesru@pentair.com SERBIA AND MONTENEGRO Tel. +381 230 401 770 Fax +381 230 401 770 salesee@pentair.com SCHWEIZ / SUISSE Tel. 0800 551308 Fax 0800 551309 info-ptm-ch@pentair.com SUOMI Puh. 0800 11 67 99 Telekopio 0800 11 86 74 salesfi@pentair.com SVERIGE Tel. +46 31 335 58 00 Fax +46 31 335 58 99 salesse@pentair.com TÜRKIYE Tel. +90 530 977 64 67 Fax +32 16 21 36 04 ptm-sales-tr@pentair.com UNITED KINGDOM Tel. 0800 969013 Fax 0800 968624 salesthermaluk@pentair.com WWW. PENTAIRTHERMAL.COM All Pentair trademarks and logos are owned by Pentair or its global affiliates. Pentair reserves the right to change specifications without prior notice. 2013-2016 Pentair. THERMAL BUILDING SOLUTIONS EN-RaychemGreenLeafEU-IM-EU0637 Rev0