Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:

Similar documents
4 in 1 Digital Thermostat Control

Digital Thermostat Models: VS30W and VS30B

Digital Thermostat. Models: VS35W and VS35B INSTALLER / USER MANUAL

230v Dial Thermostat Instruction Manual

Wireless Thermostats 230v and Battery Operated Quick Set-up Guide

Model: Touch-RF. 1 Wireless Series

Model: PRT-TS / PRT-NTS

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

Model: PRT2-TS / PRT2-NTS EU. Model: Touch Duo

Drayton Digistat +3RF

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

Operating Instructions Model : HC HC-N

Operating Instructions Model: PRT-TS WiFi RF. 01/13 Version 1 Ref: PRT-TSWIFI RF

Underfloor Heating Programmable Thermostat

Model: Touch-RS. 1 Touch-RS

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

Model: RT510RF. Installation Manual

Operating Instructions

: PRT / PRT PRT / PRT-N1

Digital Room Thermostat

Model: Available in : Sapphire Black and Glacier White. 1 Series

Model : PRT-EN Model: PRT-EN1

Operating Instructions Model: PRT/HW - PRT/HW-N Version 3. 09/09 Revision 2 Ref: PRT/HW/NV3

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

Model: Slimline-RF. 1 Slimline Series

PRT-TS WiFi PRT-TS WiFi

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

RF Programmable Room Thermostat Installation Instructions

Programmable Room Thermostat Installation Instructions

Contents.

Model: Slimline-N. 1 Slimline Series

ETN-24-SUPER-PROG (US Program - Celsius)

MAKING MODERN LIVING POSSIBLE. FP975 7-Day Electronic Programmer. User Guide. Danfoss Heating

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

Easy-Stat. Wireless Programmable Room Thermostat Pt No

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

ES3247B. 3 Channel Programmer. User and Installation Instructions

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

User Manual THR870CUK Programmable Thermostat

Installation and Advanced Programming Instructions. HP8211-1RJ and HP8321-1RJ Heat Pump Thermostats

Programmable Thermostat with Plug in RF Boiler Control Model: ST620VBC INSTRUCTION MANUAL

Owner s Manual. Part Number 33CS250-RC

CS027 User Instructions

C-Stat 17-ZW User Instructions

Model: Available in: Sapphire Black and Glacier White. 1 Series

OWNER S MANUAL. Part Number P RF

Model: Edge-HC. 1 edge-hc

MAKING MODERN LIVING POSSIBLE. CP715Si. Electronic 2-Channel Common Timebase Programmer for Heating and Hot Water. User Guide.

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

WLM2 WLTA WLTD WLTP WLCT2

TB8220U Commercial Programmable Thermostat OWNER S GUIDE

4 Wiring Brochure Wiring and

Electronic Dual Cylinder Thermostat Installation Instructions

Product Manual SZ1022/SZ1031/SZ1035/

Model: Slimline-B. Battery Series

ComfortSense 7500 Commercial Thermostat. User Guide

AUTO CM CM USER GUIDE

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

COMF RT SYSTEM. T-32-TS Touchscreen Thermostat. User Manual

Phone-A-Stat. MODEL Command Center With Thermostat Operation, Maintenance & Installation Manual. Introduction.

Eswa DC-1. Thermostat for Floor Heating

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

User s Manual

Vokèra OpenTherm 711 with external sensor connected

Model: RT310i. Smartphone Controlled Thermostat. Installation Manual

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

SAS803WHL-7 Thermostat for floor heating

INSTALLATION & USER MANUAL

User Manual THR872CUK Wireless Programmable Thermostat

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

Battery Powered Electronic Programmable Room Thermostat

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology

Please read this manual carefully before installation and use.

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

AQUATROL Zone Synchronizing Universal Injection/Mixing Boiler Reset Controls AQ252

103E7. User Guide. 7-Day Electronic Timeswitch for Controlling Hot Water and Heating (Including Factory Replacement Units FRU) Danfoss Heating

SYX660 Commissioning Guide V Page 1 of 55

irad Wireless Controller

Operating Instructions

Maincor Air Temperature Controls AIR TEMPERATURE CONTROL

5245 / Thermotouch 4.3dC. Dual Control Thermostat. Installation & User Guide

DEVIreg Opti Electronic Timer Thermostat fulfilling Eco Design Directive

Odyssey. issue 01c. system manual

CentaurStat 7 User Operating Instructions Central Heating Programmable Room ThermoStat

Room thermostat with Auto Timer, independent DHW

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

Ocean Breeze Model QU700 Programmable Digital Touchscreen Climate Control

Model: RT310. Installation Manual

Vokèra OpenTherm 711 without external sensor connected

3 Channel Multi-Purpose Programmer User Instructions

Energy Plannersm Programmable Thermostat Customer Guide. Take control of your comfort and energy savings

Safety & Installation Instructions

Elegance. SMT-700 User manual. Ver

Product Manual SZ1009

Transcription:

Contents Box contents: Instruction Manual Instruction manual: Box contents Introduction Product compliance System options overview Installation Parameter settings Error codes User guide Installers notes Fixing screws JGSTAT2W (White) Icons used in this manual: Safety Important info Your benefit JGSTAT2B (Black) For latest PDF Instruction Manual please go to www.speedfitufh.co.uk 02 JGSTAT2 Instruction Manual

Product Compliance & Safety Information Introduction. Thank you for purchasing one of our Speedfit Aura 230V Thermostat models. To use all of the Thermostat features, the optional communications cables is required. The unit can be configured to be a Programmable Room Thermostat (PRT), Group Control Thermostat, Group Thermostat or Hot Water Timer. Communication between neighbouring JGSTAT2 and JGSTAT1 Dial Thermostats is possible via the JGWC Wiring Centre (pictured below) and the optional communications cables. More information can be found on pages 9 and 10. Product Compliance. This product is CE compliant and meets the following EC Directives: RoHS2 2011/65/EU, Electro- Magnetic Compatibility directive 2004/108/EC and Low voltage directive 2006/95/EC. Safety Information. Use in accordance with the regulations. The Aura JGSTAT2 is to be used for room control of heating and hot water systems inside buildings. We hope you enjoy this product... Speedfit Aura Wiring Centre JGWC www.speedfitufh.co.uk 03

Product Compliance & Safety Information These instructions are applicable to the Speedfit Aura model stated on the front cover of this Instruction Manual only. Warning. This product must be fitted by a competent person. Installation must comply with the guidance, standards and regulations applicable to the location where the product is installed. Failure to comply with the requirements of the relevant guidance, standards and regulations could lead to injury, death or prosecution. Sources of danger. The thermostat must be disconnected from mains supply before removing the cover. Emergency. Switch off the voltage to the individual thermostat, wiring centre or complete system. 230v AC Warning. Always isolate the AC Mains supply before installing or working on any components that require 230v AC 50Hz supply. Installer parameter settings. The Aura JGSTAT2 is equipped with an Installer Parameter section (see page 40). This must only be entered by the installer or a competent person. Changing these parameters can have a serious effect on your heating system. For the installer. Please enter any parameter changes in the Installer Notes section (pages 72-75). 04 JGSTAT2 Instruction Manual

System Overview - Configuration Options 1 2 Group Control Thermostat Programmable Room Thermostat (PRT) The unit can be configured to either one of the following. Wiring Centre SYSTEM OVERVIEW 3 Group Thermostat 4 Timer UFH Manifold Radiator Boiler Hot Water www.speedfitufh.co.uk 05

System Overview - Configuration Options Programmable Room Thermostat (PRT). When configured for PRT (see page 31) the Programmable Room Thermostat mainly works by itself and allows the user to have separate Time and Temperature control of each zone on the wiring centre. Features like Holiday, Party and Frost mode have to be set on each individual thermostat. The PRT can be configured for global heat/cool system changeover if your system supports this. This is achieved from a switched input from the Wiring Centre (see the Wiring Centre Instruction Manual). Communication Connection (see page 13) is required to use heat/cool changeover function. Group Control Thermostat. When configured as a Group Control Thermostat (see page 33), the unit allows central control of up to 7 Group Thermostats (see below). There can be a maximum of 2 groups per 8 zone wiring centre. Permanent temperature override, Holiday, Party and Frost modes can be selected centrally from the Group Control Thermostat. Holiday mode will also be applied to a timer if applicable. Communication connections (see page 13) are required for grouping the Group Thermostats. Thermostats can be also globally changed from heating to cooling thermostats if your system supports this by using the switched input connection on the JGWC (see the Wiring Centre Instruction Manual) along with the Communications connections mentioned above. Group Thermostat. When configured as a Group Thermostat (see page 36), the unit will follow the time schedule and override modes of the Group Control Thermostat. The Group Thermostat can have its own programmed temperatures, Manual Override and also be removed from the group temporarily or permanently. Communication connections are required (see page 13). Timer. When configured as a Timer (see pages 32 and 34), the unit will operate without temperature control. In this configuration, the unit can be used as a Hot Water Timer. The Timer will also follow a Group Control Thermostat when Holiday mode has been activated (requires communication connections). 06 JGSTAT2 Instruction Manual

System Overview - Cables Power and Switching cable used to power thermostats and drive output. SYSTEM OVERVIEW Grouping and Communication cable. While the units can function as standalone PRTs or Timers, installing this optional inexpensive Communication cable allows the units to communicate with each other. This allows a thermostat to assume convenient remote control of a group. This brings central control of features such as Time Control, Holiday and Party functions as well as Frost Control. The individual group members can leave or re-enter group control at the push of a button. Communication cable can be used when units are used as individual PRT's for heat/cool changeover. Please refer to page 13 and the Wiring Centre Instruction Manual. Cable size 1.5mm 3 core for L,N,SL and 0.5mm twin for the communication. www.speedfitufh.co.uk 07

System Overview - Options The systems below, although not exhaustive show the main options. The maximum number of groups per JGWC Wiring Centre is two. The group selection communication cable must correspond to the group terminals on the JGWC Wiring Centre. Please refer to the JGWC Instruction Manual. Option 1 - Page 09. Unit is configured as individual PRT. All digital variants can be configured from JGSTAT2. Groups must have a Group Control Thermostat. 1 or 2 groups can be used per wiring centre. HW Timer can be stand alone or part of a group. If using HW Timer as part of a group it must be in Group 1. Option 2 - Page 10. Unit is configured as a Group Control Thermostat used to control a group(s) of unit(s) configured as Group Thermostats. Group 1 Group 2 Option 3 - Page 10. Unit is configured as a Group Control Thermostat used to control a group(s) of Digital Stat(s) configured as Group Thermostats. Group 1 Group 2 08 JGSTAT2 Instruction Manual

System Overview - Grouping and Communication Option 1 - Page 31. All thermostats set as PRT. FUNCTION PRT USING COMMUNICATION CONNECTION - PRT Individual Room Control 4 4 Individual Holiday Function 4 4 Individual Party Function 4 4 Individual Heating Program 4 4 Individual Frost Function 4 4 Group Holiday including HW 6 6 Group Party 6 6 Group Heating Program 6 6 Group Permanent Override 6 6 Group Temporary Override 6 6 Heat/Cool changeover 6 4 SYSTEM OVERVIEW Note: The communication connection is only used for heat/cool changeover when using units configured to PRT s and using the relevant connection on the JGWC Wiring Centre. Please refer to the Wiring Centre Instruction Manual. www.speedfitufh.co.uk 09

System Overview - Grouping and Communication Option 2 - Page 33 Option 3 - Page 35 FUNCTION PRT USING COMMUNICATION CONNECTION - GROUP CONTROL Individual Room Control 4 4 Individual Holiday Function 4 4 Individual Party Function 4 4 Individual Heating Program 4 4 Individual Frost Function 4 4 Group Holiday including HW 6 4 Group Party 6 4 Group Heating Program 6 4 Group Permanent Override 6 4 Group Temporary Override 6 4 Heat/Cool changeover 6 4 Note: HW timer will only use HOLIDAY mode when the communication connection is used. Also the HW Timer must be connected to GROUP 1 communication terminals on the Wiring Centre. Please see the Wiring Centre Instruction Manual. 10 JGSTAT2 Instruction Manual

System Overview - Hot Water Option When the unit is configured as a Hot Water Timer (see page 34) there are two methods of connecting the cylinder thermostat. SYSTEM OVERVIEW Unit configured to Hot Water Timer. Cylinder thermostat options: 1 2 Connected directly to JGWC (default). Connected directly to JGSTAT2. www.speedfitufh.co.uk 11

+ 2 1 SL L N + 2 1 SL L N + 2 1 SL L N + 2 1 SL L N System Overview - Hot Water Option For convenience there is a unique built in option allowing the cylinder thermostat to be connected to either the HW Timer or Wiring Centre. 1 Connected direct to JGWC (default). 2 Connected direct to JGSTAT2 (requires additional parameter change see page 40). Please refer to the Wiring Centre Instruction Manual and page 18 for more information. 12 JGSTAT2 Instruction Manual

Installation - Terminal Connections Understanding your terminal connections. Rear of unit 1 Communication Terms 12v DC. Two wire twisted pair can be used for Grouping Functions between Group Control Thermostat, Group Thermostat and HW Timer. INSTALLATION 1 2 3 2 3 Sensor Terminals. Can be used for external AIR or Floor sensor when configured as thermostat. Can also be used for cylinder thermostat when configured for HW. Power Terminals 230v AC. Used for supplying power to the unit and switched output. www.speedfitufh.co.uk 13

Installation - Thermostat Mounting 1 2 3 Carefully remove the front housing. 60mm 14 JGSTAT2 Instruction Manual

Installation - Thermostat Mounting Mounting position and installation. To ensure trouble free operation and efficient control, the unit is best positioned in a draft free area and at 130cm from the floor. Do not position the thermostat near any heat source, behind curtains, in direct sunlight or an area of high humidity. INSTALLATION 130cm Not to be positioned on an exterior wall. www.speedfitufh.co.uk 15

SL N L SL N L SL N L SL N L SL N L SL N L SL N L SL N L ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 5 x 20mm 5 x 20mm Installation - Thermostat Connections Optional communication connection 12v DC While the thermostats can function as PRT or Timers, installing this optional inexpensive Communication Cable allows the thermostats to communicate with each other. This allows the thermostat to assume convenient remote control of groups of thermostats bringing central control of features such as Time Control, Holiday and Party functions as well as Frost Control. The individual group members can leave or re-enter group control at the push of a button. For more detail refer to the Wiring Centre Instruction Manual. 16 JGSTAT2 Instruction Manual

Installation - Thermostat External Sensor INSTALLATION Aura External Sensor (sold separately). Note: If you are using an External Sensor, the unit has to be configured for External Air Sensor or Floor Protection Sensor. Please see Device Parameter Setting on page 40. www.speedfitufh.co.uk 17

SL N L SL N L SL N L SL N L SL N L SL N L SL N L SL N L ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 5 x 20mm 5 x 20mm Installation - Hot Water Timer Wiring Optional communication connection 12v DC If hot water is part of a group then the communication connection must be connected to group 1. SL N L Power Connections 230v AC - - - - ++++ GROUP 2 GROUP 1 18 JGSTAT2 Instruction Manual

SL N L SL N L SL N L SL N L SL N L SL N L SL N L SL N L ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 5 x 20mm 5 x 20mm SL N L SL N L SL N L SL N L SL N L SL N L SL N L SL N L ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 ZONE 7 ZONE 8 5 x 20mm 5 x 20mm Installation - Hot Water Timer Cylinder Thermostat INSTALLATION Cylinder thermostat Link must be fitted IN OUT WC connected cylinder to thermostat (Default). IN OUT HW Timer connected to cylinder thermostat. Note: Optional - The JGSTAT2 can be configured for a connection to a cylinder thermostat. Please see Device Parameters on page 40. For additional wiring centre information refer to the Wiring Centre Instruction Manual. www.speedfitufh.co.uk 19

Installation - Thermostat Mounting Check that the wiring is completed for: 1 2 3 Power terminals. Sensor terminals (if applicable). Communication connections (optional but recommended). You are ready to secure the rear housing to the wall box. Please use the screws provided. Ensure the orientation arrow is pointing upwards. 20 JGSTAT2 Instruction Manual

Installation - Thermostat Mounting Fit the front housing to the rear housing. Ensure the pin connections are aligned. INSTALLATION 1 2 Align the front housing at the bottom edge. Lightly press until you hear a positive click. www.speedfitufh.co.uk 21

Installation - LCD Graphics ICON FUNCTION Box: Indicates selected mode e.g. means the current setpoint is Hi temp, means the Hi temp is not selected. Sunny: Hi comfortable temperature. Cloudy: Middle comfortable temperature. Moon: Low comfortable temperature. Programmable Thermostat program mode indicator: Indicates program is running, Auto On or Auto Off. For Group Thermostat this indicates that it is a member of a group. Party indicator: When Party Mode is active. Holiday indicator: When Holiday Mode is active. available Frost protection indicator: Frost Protection is active, not in Cooling Mode (if applicable). 22 JGSTAT2 Instruction Manual

Installation - LCD Graphics ICON FUNCTION Heat indicator: Indicates demand for heat. INSTALLATION Cool mode indicator: Indicates cooling is required (if applicable). Temperature indicator: Displays room temperature, set temperature or other information. Temporary manual override indicator: If the set temperature is changed when in program mode, the hand will appear until the next program start time. Programs number indicator: Displayed in AUTO mode or Temporary override. The number indicates which program is running. Day indication: 1 = Monday. www.speedfitufh.co.uk 23

Installation - LCD Graphics ICON FUNCTION Hot Water (HW) indicator: Unit operating as a hot water timer. Hot Water (HW) indicator: Indicates demand for hot water. HW Program mode indicator: Indicates program is running. HW Mode indicator: Mode for 1 period of HW a day, from Program 1 ON to Program 3 OFF. HW Mode indicator: Hot water switched on (continuously). HW Mode indicator: Hot water switched off (continuously). HW Mode indicator: Indicates Boost +1hr override. 24 JGSTAT2 Instruction Manual

Installation - LCD Graphics ICON FUNCTION Floor sensor probe indicator: Show only when Air + Floor sensor is connected. INSTALLATION Setting indicator: Indicates the unit is in program setting mode. Keylock indicator: Keys have been de-activated. www.speedfitufh.co.uk 25

Installation - User Interface ICON OR OR FUNCTION 1. Increase or decrease setpoint temperature. 2. Increase or decrease Day, Clock, Timer, Party, Holiday and Boost. 3. Select Installer Parameter value. 1. Mode selection. 2. Long press to return to home display without saving. 3. Short press to return to the previous screen when it is in user/installer setting mode. 1. OK key: Short press to confirm selection. 2. Long press to save and exit. 3. Long press to enter the user settings. + LONG PRESS Lock/Unlock. + + LONG PRESS + LONG PRESS Enter Installer Parameter settings. Test mode. 26 JGSTAT2 Instruction Manual

Installation - First Power Up INSTALLATION www.speedfitufh.co.uk 27

Installation - System Parameters You are now ready to configure the unit using the System Parameter table below. SX FUNCTION SYSTEM DEFINITION DEFAULT SETTING System Unit 0 Programmable Room Stat (PRT) SO1 Type 1 Digital Thermostat 0 2 HW Timer 0** PRT only with communication* System 1* Group Control Thermostat and S03 Group Thermostat communication 1 Communication 2 No Communication / Grouping required *S03 setting 1 is used for Control Group options 2 and 3 see pages 33-36, communication connection must be used, global heat/cool changeover is also included if applicable to your system. **S03 setting 0 is used for option 1 (see page 31) when heat/cool changeover is required for individual PRTs, communication connections must be used for this function. S03 setting 0 is only available if setting 0 has been selected for S01. If no heat/cool changeover is required when using PRTs only then select setting 2 for S03. 28 JGSTAT2 Instruction Manual

Installation - Options Option 1 - Page 31. Unit is configured as individual PRT. INSTALLATION Option 2 - Page 33. Unit is configured as a Group Control Thermostat used to control a group(s) of Dial Stat(s). Group 1 Group 2 Option 3 - Page 35. Unit is configured as a Group Control Thermostat used to control a group(s) of Digital Stat(s) configured as Group Thermostats. Group 1 Group 2 An additional Hot Water Timer can be used with any of the above options. www.speedfitufh.co.uk 29

Installation - Graphics Key Press once xx Press x amount of times Hold for five seconds Flashing Short press to back up Short press to save and long press to save and exit 30 JGSTAT2 Instruction Manual

Option 1 - Individual Programmable Thermostat Setup PRT with no communication *. INSTALLATION Short press on to back up. Use to change to 2. OPTION 1 Long press to exit to home screen or continue to change device settings. Refer to page 33. *Select S03 setting 0 if communication is required for global heat/cool changeover. Your system must support this and the communication connection must be used (see page 13). www.speedfitufh.co.uk 31

Option 1 - Hot Water Timer (Optional) Configuration Hot water with no communication. Use to change to 2. Use to change to 2. Long press to exit to home screen or continue to change device settings. Refer to page 40. 32 JGSTAT2 Instruction Manual

Option 2 - Thermostat Configuration Group Control Thermostat. INSTALLATION OPTION 2 Communication connection required for this setting. Long press to exit to home screen or continue to change device settings. Refer to page 40. www.speedfitufh.co.uk 33

Option 2 - Hot Water Timer (Optional) Configuration Use to change to 2. Communicatio n connection required for this setting. Long press to exit to home screen or continue to change device settings. Refer to page 40. 34 JGSTAT2 Instruction Manual

Option 3 - Thermostat Configuration Group Control Thermostat. OPTION 3 INSTALLATION Communicatio n connection required for this setting. Long press to exit to home screen or continue to change device settings. Refer to page 40. www.speedfitufh.co.uk 35

Option 3 - Thermostat Configuration Group Thermostat. Use to change to 1. Communicatio n connection required for this setting. Long press to exit to home screen or continue to change device settings. Refer to page 40. 36 JGSTAT2 Instruction Manual

Option 3 - Hot Water Timer (Optional) Configuration Use to change to 2. INSTALLATION OPTION 3 Communicatio n connection required for this setting. Long press to exit to home screen or continue to change device settings. Refer to page 40. www.speedfitufh.co.uk 37

Installation - System Parameters If you have made an error or need to change your System Parameters please follow the steps below. This should only be done by your installer. Press all three buttons simultaneously. 38 JGSTAT2 Instruction Manual

Installation - System Parameters Unit will follow power up sequence on page 27. INSTALLATION You are now ready to enter or change your System Parameters. Refer to page 28. www.speedfitufh.co.uk 39

Installation - Device Parameters Press all three buttons simultaneously. Device Parameters will follow System Parameters on first power up. If you need to change Device Parameters follow the steps below. Please note, your System Parameters will be shown first but cannot be edited in this section. To change the System Parameters please refer to the previous two pages. 40 JGSTAT2 Instruction Manual

Installation - Device Parameters DX FUNCTION SYSTEM DEFINITION DEFAULT SETTING D01 D02 D03 D04 D05 D06 D07 Heating control Room temperature offset 0 Pulse width modulation 1 On-Off 0.5ºC +/- 0.25ºC 0 2 On-Off 1.0ºC +/- 0.5ºC Temperature offset from -3.0ºC to measured temperature to 3.0ºC compensate for any error 0ºC Sensor probe or 0 Sensor/Cylinder stat not connected cylinder thermostat connection 1 Sensor/Cylinder stat connected Sensor probe used as air sensor or floor sensor Cooling control Actuator type Valve protection D03 must be set to 1 then external 0 sensor be used as Air sensor. There will be no internal temp measurement D03 must be set to 1 then external 1 sensor used for floor protection. Internal temp is measured by stat 1 On-Off 0.5ºC +/- 0.25ºC 2 On-Off 1.0ºC +/- 0.5ºC 0 NO normally open 1 NC normally closed 0 Disable 1 Enable www.speedfitufh.co.uk 0 0 2 1 1 INSTALLATION 41

Installation - Device Parameters continued DX FUNCTION SYSTEM DEFINITION DEFAULT SETTING D08 Frost Set point temperature 5ºC to 17ºC Required temperature for Frost Protection and Holiday Mode D09 Hour format 0 12 1 1 24 D10 N/A N/A N/A N/A D11 Daylight Saving 0 OFF Time (DST) 1 ON D12 Heating Set point 5ºC to 35ºC Maximum temp that can limit be set for heating D13 D14 D15 D16 5ºC 1 35ºC Cooling Set point 5ºC to 40ºC Maximum temp that can 5ºC limit be set for Cooling Floor sensor high limit temperature Floor sensor Low limit temperature Floor sensor limit for cooling 42 JGSTAT2 Installation Manual Output relay will be switched off 6ºC to 45ºC when temp is reached for 27ºC floor protection Output relay will be switched on 6ºC to 45ºC when temp is reached for 10ºC floor protection Output relay will be switched off 6ºC to 45ºC when temp is reached for 6ºC floor protection

Installation - Error Codes ERROR PROG NON-PROG HW CODE 01 Comm Connection Comm Connection Comm Connection link failure link failure link failure 02 Comm Connection Comm Connection Comm Connection link failure link failure link failure 03 Floor sensor open Floor sensor open - 04 Floor sensor short Floor sensor short - INSTALLATION When an error exists within the system, the thermostat display will cycle between the normal operating screen and an error page. If there is more than 1 error, then on Error page, press UP to show other error codes. e.g. Err 03 05 ===> 3 errors Error code 05 (1st one). Press Up to show Err 03 08 ===> 3 errors Error code 08 (2nd one). Press Up again to show Err 03 09 ===> 3 errors Error code 09 (3rd one). Press Up again to show Err 03 05 again... Press OK to exit Error page back to Home display. www.speedfitufh.co.uk 43

Installation - Technical Detail Model Type Programming Modes Program Number Modes Override Frost Protection Power Source Rating Communication Bus Temperature Scale JGSTAT2W or JGSTAT2B Electronic programmable room thermostat, digital room thermostat and hot water timer designed for 230v AC applications User selectable for 5/2, ALL and Individual day options 1-6 Selectable Party, Vacation, Program and Frost Permanent and temporary 5ºC Adjustable. 230v AC 50Hz 3 Amp 12v DC 5ºC to 35ºC, tolerance 0.5ºC Heat/Cool Global changeover using communication bus and external input to the wiring centre Sensor Air or floor protection. Cylinder thermostat when configured for hot water timer Device Parameters See page 41-42 for full list of functions Operating Temperature 0ºC to 50ºC Storage Temperature -20ºC to 60ºC 44 JGSTAT2 Instruction Manual

User Guide - Setting Time and Date PRT and Group Control Thermostat. USER GUIDE www.speedfitufh.co.uk 45

User Guide - Setting Time and Date PRT and Group Control Thermostat. Use Left to select 12 hour and right to select 24 hour. Hour Adjust the time using the up or down arrow key. Minutes 46 JGSTAT2 Instruction Manual

User Guide - Setting Time and Date PRT and Group Control Thermostat. Year USER GUIDE Adjust the year/month/d ay using the up or down arrow key. Month Day www.speedfitufh.co.uk 47

User Guide - Understanding Temperature Levels Heating PRT, Group Control Thermostat and Group Thermostat. Highest temperature typically used for early morning and early evening. Typically 21ºC. Mid temperature typically used for times of day when you are active around the home. Typically 19ºC. Lower temperature typically used for unoccupied or sleep times. Typically 17ºC for UFH or 15ºC for radiators. Frost temperature typically used for periods of long absence or holidays. Typically 5ºC. Your thermostat comes preset for the above temperatures. These can be adjusted please see page 53. 48 JGSTAT2 Instruction Manual

User Guide - Understanding Temperature Levels Cooling PRT, Group Control Thermostat and Group Thermostat. Cooling is only available if your system supports this and the relevant configurations and connections have been made to the unit. USER GUIDE Occupied temperature typically 22ºC. Unoccupied temperature typically 40ºC. This avoids cooling being active when the property is unoccupied. Evening temperature typically 24ºC. Your thermostat comes preset for the above temperatures. These can be adjusted please see page 53. www.speedfitufh.co.uk 49

User Guide - Default Heating Schedule PRT and Group Control Thermostat. Monday to Friday 21 19 17 12.00 7.00 9.00 17.00 23.00 Saturday to Sunday 21 19 17 12.00 8.00 9.00 17.00 23.00 If using grouping, the schedule from the Group Control Thermostat will be applied to Group Members. 50 JGSTAT2 Instruction Manual

User Guide - Default Cooling Schedule PRT and Group Control Thermostat. Monday to Friday 22 USER GUIDE 40 24 12.00 7.00 9.00 17.00 23.00 Saturday to Sunday 22 40 24 12.00 8.00 9.00 17.00 23.00 If using grouping, the schedule from the Group Control Thermostat will be applied to Group Members. www.speedfitufh.co.uk 51

User Guide - Graphics Key Press once xx Press x amount of times Hold for five seconds Flashing Short press to back up Short press to save and long press to save and exit 52 JGSTAT2 Instruction Manual

User Guide - Setting Required Temperature Levels PRT, Group Control Thermostat and Group Thermostat. Setting the low temperature. USER GUIDE By setting the low temperature the program schedule will use this as the low setting. The temperature set is applicable to the individual thermostat. www.speedfitufh.co.uk 53

User Guide - Setting Required Temperature Levels PRT, Group Control Thermostat and Group Thermostat. By setting the low temperature the programs will use this as the low setting. Repeat for Move back to once temperature levels have been chosen. The temperature set is applicable to the individual thermostat. 54 JGSTAT2 Instruction Manual

User Guide - Setting the Temperature Schedule Use right and left to select the day of the programs. USER GUIDE If using grouping, the schedule from the Group Control Thermostat will be applied to Group Members. 5/2 7 Days Individual www.speedfitufh.co.uk 55

User Guide - Setting the Temperature Schedule Adjust the time using the up or down arrow key. Use right and left to select the Hi/Mid or low temp. 56 JGSTAT2 Instruction Manual

User Guide - Setting the Temperature Schedule Repeat through to program 4. If you require a 5th or 6th program enter a time and select your temperature USER GUIDE To remove a program, set the time to --:--. When you set the temperature the schedule will respond to those temperatures. Please see page 53 on how to change www.speedfitufh.co.uk 57

User Guide - Temporary Override PRT, Group Control Thermostat and Group Thermostat. Use the up or down arrow key to view your program set temperature. The Temporary Override is applicable to the thermostat being changed only. Temporary Override allows you to increase the temperature or decrease it to the desired setting until it reverts back on the next program time. Use the up or down arrow key to adjust the temperature to the setting you desire. 58 JGSTAT2 Instruction Manual

User Guide - Temporary Override PRT, Group Control Thermostat and Group Thermostat. Confirm the temporary set temperature. USER GUIDE To cancel temporary override press (see below). or www.speedfitufh.co.uk 59

User Guide - Permanent Override PRT and Group Control Thermostat. Setting permanent low temperature. Move from to Use the up or down arrow key to view your set temperature. See page 58. Permanent Override of a Group Control Thermostat will also affect the Group Thermostats unless they are removed from the group. See page 64. To cancel Permanent Override select See below. Repeat for if required 60 JGSTAT2 Instruction Manual To adjust your Permanent Override temperature, follow the steps on page 53.

User Guide - Party Mode PRT and Group Control Thermostat. The Party Mode is an option that enables temperature for a period of time (up to 9hr 50min). Use the right arrow to select the Party Mode. USER GUIDE Use the up arrow to select the hr/min. Party Mode set in a Control Group Thermostat will also affect Group Thermostats unless they are removed from the group. See page 64. Press tick to confirm and it will start to count down. www.speedfitufh.co.uk 61

User Guide - Holiday Mode Holiday set in a Group Control Thermostat will also affect Group Thermostats unless they are removed from the group. See page 64. Holiday mode switches heating to frost mode for the set number of days. Group control (if used) will also disable the hot water. Use the right arrow to select the Holiday Mode. Use the up arrow to select how many days to be off for. Press tick to confirm and it will start the holiday count down. 62 JGSTAT2 Instruction Manual

User Guide - Frost Protection Frost protection set in a Group Control Thermostat will also affect Group Thermostats unless they are removed from the group. See page 64. Use the right arrow to select the Frost Mode. Use the up arrow to select the frost protection temperature. USER GUIDE Frost protection is not available in Cooling. Moving the to this position in Cooling will switch the thermostat to off. Press tick to confirm the temperature setting. www.speedfitufh.co.uk 63

User Guide - Group Thermostat Overview When a Group Thermostat is in it will follow the Mode status of the Group Control Thermostat. When a Group Thermostat is in and the Group Control Thermostat is in or then the Group Thermostat will follow this mode. or will be displayed. The Group Thermostat has now left the group and is in permanent To adjust the set temperature, please refer to pages 53-54. The Group Thermostat has now left the group and is in permanent To adjust the set temperature, please refer to pages 53-54. 64 JGSTAT2 Instruction Manual

User Guide - Group Thermostat Overview The Group Thermostat has now left the group and is in permanent To adjust the set temperature, please refer to pages 53-54. USER GUIDE The Group Thermostat has now left the group and is in permanent To adjust the set temperature, please refer to page 53-54. The Group Thermostat has been returned to it will follow the mode status of the Group Control Thermostat. www.speedfitufh.co.uk 65

User Guide - Hot Water (Optional) Mode Selection Mode selection. Hot water will be on once per day. Hot water will be continuously on. When is selected, the hot water timer will follow the program schedule (see page 68). 2 Hot water will be continuously off. 3 Hot water will follow Holiday Mode from the Group Control Thermostat. will be displayed. 66 JGSTAT2 Instruction Manual

User Guide - Hot Water Boost USER GUIDE www.speedfitufh.co.uk 67

User Guide - Setting Hot Water Times Your Hot Water Timer comes preset with the times below. These can be adjusted (see next page). Monday to Friday ON ON OFF OFF OFF 12.00 6.00 8.00 18.00 22.00 Saturday and Sunday ON ON OFF OFF OFF 12.00 6.00 8.00 18.00 22.00 68 JGSTAT2 Instruction Manual

User Guide - Setting Hot Water Times USER GUIDE 5/2 7 Days Individual www.speedfitufh.co.uk 69

User Guide - Setting Hot Water Times Repeat these steps for programs 70 JGSTAT2 Instruction Manual

User Guide - Setting Hot Water Times USER GUIDE Repeat these steps for programs www.speedfitufh.co.uk 71

Installer Notes 72 JGSTAT2 Instruction Manual

Installer Notes www.speedfitufh.co.uk 73

Installer Notes 74 JGSTAT2 Instruction Manual

Installer Notes www.speedfitufh.co.uk 75

John Guest Speedfit Limited Horton Road, West Drayton, Middlesex UB7 8JL, England. Tel: 01895 449233 Fax: 01895 420321 www.speedfitufh.co.uk Technical Help Desk: 01895 425333, and The above namestyles are all trademarks of John Guest International Limited. John Guest International Limited 2014. All rights reserved. Z2105/421/0814