Vokèra OpenTherm 711 with external sensor connected

Similar documents
Vokèra OpenTherm 711 without external sensor connected

CS027 User Instructions

PROGRAMMABLE 7-DAY THERMOSTAT

PROGRAMMABLE 7-DAY RF THERMOSTAT

C-Stat 17-ZW User Instructions

ECL Comfort 210 / 296 / 310

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY

Model: Slimline-RF. 1 Slimline Series

BeSMART Thermostat. EN Thermostat Manual

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

Easy-Stat. Wireless Programmable Room Thermostat Pt No

Model: Slimline-B. Battery Series

irad Wireless Controller

Model: Available in : Sapphire Black and Glacier White. 1 Series

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

Drayton Digistat +3RF

Underfloor Heating Programmable Thermostat

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

: PRT / PRT PRT / PRT-N1

Model : PRT-EN Model: PRT-EN1

Slimline Curve Electric Radiator. Step by Step Programming Guide

Model: Available in: Sapphire Black and Glacier White. 1 Series

Model: Slimline-N. 1 Slimline Series

Powermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage

Installation & User s Instructions

ThermoPlus AS2-RF & ASR-RF Installation Instructions

WLM2 WLTA WLTD WLTP WLCT2

Owner s Manual. Part Number 33CS250-RC

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

AUTO CM CM USER GUIDE

Designer TT Programme Set Up

Quickheat 30 weather compensated boiler control

User Manual THR870CUK Programmable Thermostat

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

Installation Guide. ECL Comfort 210, application A Table of Contents

Model: PRT-TS / PRT-NTS

OWNER S MANUAL. Part Number P RF

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

EUROSTER 2510 USER MANUAL 1 EUROSTER 2510

Programmable Thermostat

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

Planet Super4F.S. User Instructions

P20. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort P20. User's Guide. Installer's Guide *VI7BD502* *087R8014* *087R8014* *VI7BD502*

CDE2TI, CDE2TIB, CDE2ECC, CDE2ECCB, CDE24ECC & CDE24ECCB AUS/NZ

Model: Touch-RF. 1 Wireless Series

ProCon Boiler Controller Commissioning Quick Reference Guide

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

PRT-TS WiFi PRT-TS WiFi

Modulating clock thermostat

SINGLE-CHANNEL PROGRAMMER FITTING AND OPERATING INSTRUCTIONS

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

ENGLISH. REMOTE CONTROL / ROOM THERMOSTAT Wireless INSTALLATION SERVICING AND USER MANUAL

Operating Instructions Model: PRT-TS WiFi RF. 01/13 Version 1 Ref: PRT-TSWIFI RF

The Vitro-i. Radiant / Convector Combination Heater. Instructions for Operation and Installation

TABLE OF CONTENTS. IMPORTANT Please read this manual carefully.

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

Operating your heating system with the Prefect PRE5701 Programable Thermostat

Operating Instructions Model: PRT/HW - PRT/HW-N Version 3. 09/09 Revision 2 Ref: PRT/HW/NV3

User Guide Y9420H Sundial RF 2 Pack 2

Owner s Manual. Part Number 33CS250-01

Model: PRT2-TS / PRT2-NTS EU. Model: Touch Duo

Model: Edge-HC. 1 edge-hc

User Guide for EHE & EHE Programmable Room Thermostat

USERS GUIDE. Electronic Timer, 7 day. LOGIC+ Combi, LOGIC Combi & LOGIC Combi E 24, 30, 35

CentaurStat 7 User Operating Instructions Central Heating Programmable Room ThermoStat

User Manual THR872CUK Wireless Programmable Thermostat

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Product Manual SZ1009

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

OWNER S MANUAL. Part Number P

Model: Touch-RS. 1 Touch-RS

TYBOX PAC. * _rev1* User guide. Programmable thermostat for heat pumps

Operating instructions. For the operator. Operating instructions VRT 350. Room temperature-controlled controller GB, IE

Mynute. Standard efficiency system boiler 12e - 16e - 20e. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

Programmable Interactive User Manual

Set & $ave. Model Programmable Thermostat. installation and operation manual

T7350 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS

4 in 1 Digital Thermostat Control

Product Manual SZ1022/SZ1031/SZ1035/

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:

3 Channel Multi-Purpose Programmer User Instructions

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

CentaurPlus C27 Series 2 User Operating Instructions

Elegance. SMT-700 User manual. Ver

Operating Instructions

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer

T7351 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS

Owner s Manual. Part Number 33CS250-FS and 33CS220-FS

REA22 Room Temperature Controller

1F97-51 OPERATION GUIDE WHITE-RODGERS. Operator: Save this booklet for future use! 7-Day Programmable Electronic Digital Thermostat

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

ST9400A User Guide. Features

Transcription:

Vokèra OpenTherm 711 with external sensor connected Setup guide to using the OpenTherm Control with an external weather compensation sensor fitted. If you are unsure if an external sensor is fitted check the receiver unit. If the amber LED is lit there is an external sensor fitted, so continue with this guide. If there is not solid amber LED use the other guide. A flashing amber LED indicates loss of signal between room unit and receiver (check the battery in the room unit). When the OpenTherm control is installed it overrides the controls on the boiler fascia. For example the OT Control will override the heating and hot water temperature settings on the boiler fascia. So your OT controller is now the means by which you control your heating system and boiler. It also overrides any other room thermostat or time control previously fitted to the system which may still be connected. When the OpenTherm Control is connected to your boiler with an external weather compensation sensor fitted, the room unit operates and displays differently than when no sensor is fitted. With a weather compensation sensor fitted the room unit will have been programmed by the engineer with a heating curve set to give you an internal comfort level of 20 C when the weather outside is at the lowest anticipated temperature for your part of the country. In use if you find your heating too hot or cold, adjustment is possible to a maximum of 5 C above or below the default temperature of 20 C. With a weather compensation sensor fitted the heating gradient to the left of the display shows a pair of bars. Note for engineers: The heating curve must be set up on the room unit. Do not set a heating curve on the boiler by following the instructions in the boiler manual as the OpenTherm control overrides the boiler settings. The curve is set on the boiler only when an external sensor is fitted without an OpenTherm.

Contents: 1. Manual operation of heating system. 2. Ready to go preset heating programme. 3. Setting the time of day on the room unit. 4. Setting the day on the room unit. 5. Setting the heating temperature levels and the times. 6. Selecting heating modes on the OpenTherm Control. 7. Fast adjustment of the room temperature. 8. Adjusting the hot water temperature. 9. Resetting the boiler. 10. Fault indicators on the receiver. 11. Fault codes on the OpenTherm room unit. 12. Adjusting the parameters for the OpenTherm Control.

1: Manual operation of heating: The room unit has four heating modes, OFF, TIMED, PARTY and HOLIDAY. Switch modes by pressing the heating mode selector. OFF - No vertical temperature gradient and radiator icon is shown on the left side of the screen. TIMED - Temperature gradient and radiator symbol on left side of screen (fast adjustment of temperature 5 C up or down is possible, see section 7). PARTY - Heating will operate at the comfort level for the remainder of that day then revert to timed operation at midnight (fast adjustment of temperature 5 C up or down is possible, see section 7). HOLIDAY - Heating will operate at the economy level for the duration of the holiday (no fast adjustment of the room temperature is possible in HOLIDAY mode). 2: The preset heating programme is as follows: Monday Friday: 06:00 to 08:00 and 16:00 to 22:00 at comfort temperature. At all other times the OpenTherm will maintain an economy temperature. Saturday and Sunday: 08:00 to 11:00 and 16:00 to 23:00 at comfort temperature. At all other times the OpenTherm will maintain an economy temperature. The comfort temperature default setting is 21 o C The economy temperature default setting is 16 o C If you would like to alter the preset heating programme continue with this guide. 3: Setting the time of day on the room unit: Now, press the The timeline will go blank and the time appears above Wait until the time starts to flash and then press the The hours digit alone will now appear Use the or to adjust and set the current hour Press to display the minutes digits Use the or plus to adjust and set the current minutes of the hour Now simply press the to return to the main screen Heating mode: The heating operates on time and temperature levels programmed into the room unit. The heating indicator gradient on the left of the display will be visible.

4: Setting the day on the room unit: Now, press the twice Seven numbered house icons will now appear Wait until these icons start to flash and then press the A single house icon will now appear containing a day number, for example use 1 if it is Monday Use the or to adjust the day number Now simply press the to return to main screen 5: Setting the temperature levels & the times: There are three temperature levels, they are comfort, economy and off. We will now set the comfort and economy temperatures. We suggest 20 or 21 degrees for the comfort level and 12 to 16 degrees for the economy level. twice A filled timeline, sun icon and temperature appear indicating the current comfort level Use the or plus s to select your desired comfort level temperature Once the comfort temperature is set, move to the economy level by pressing the A half-filled timeline, moon icon and temperature appears indicating the current economy level temperature Use the or s to select your desired economy level temperature Now, simply press the to return to main screen We can now select comfort, economy or off periods for different times of the day First, press the Now, press the three times A filled timeline appears Wait until it flashes Then, press the A time, house icon with the day number and a timeline with bars appear Each section in the timeline represents one hour

Each hour is divided into half hour segments Each segment can be programmed as a comfort, economy or OFF segment A blank segment represents an OFF half hour A segment with a half bar represents an economy half hour A segment with a full bar represents a comfort half hour The number in the house icon represents the day of the week being programmed, for example 1 being a Monday Now, use only, to choose the comfort, economy or off setting in the first half hour segment When selected, press the The previous segment will have automatically copied into the next half hour segment If you want to adjust this segment, use the to alter the choice or press again to move on and copy to the next segment Repeat to program the whole day to move to the next day and repeat Repeat for the week When the whole week is programmed press the to return to the main display. 6: Selecting heating modes on the OpenTherm Control: There are several override functions, which can be selected by pressing the heating mode One press of the will take you to party mode The party mode is represented by the icon, which will appear on the left side of the display above the time. This mode will override the program set for that day and operate at the comfort level continuously until midnight. After midnight the heating will revert to the timed program. The second press of the will take you to Holiday mode The holiday mode is represented by the icon, which will appear on the left side of the display above the time. The holiday mode will commence from midnight and last for the number of days selected. The days will be displayed to the right of the large house icon. Use the or s to indicate the length of the holiday. The heating will operate at the economy setting for the duration of the holiday. The third press of the, will take you to the Heating off mode In the Heating OFF mode the timeline will be empty. It is worth mentioning that if the temperature in the property falls below 5 degrees (the default frost setting, which is adjustable) the heating will come on to maintain an internal temperature of 5 degrees.

The fourth press of the, will return you to your timed heating programme 7: Fast adjustment of the room temperature on the OpenTherm Control: The room temperature level can be adjusted temporarily at any time, and it will revert back to your programmed temperature level at the next change i.e. the next off, economy or comfort segment. First press the The temperature gradient on the left of the screen will change and the room temperature setting will appear in the house icon. Now use the and the heating s (located by the radiator icon) to adjust the temperature 5 C above or below the default temperature of 20 C. Press to set new temperature. to return to the main display. 8: Adjusting the domestic hot water temperature on the OpenTherm Control: You can adjust your desired hot water temperature setting at any time. First press the Now use the and s to adjust the temperature to your desired new setting. The temperature gradient on the right of the screen will change, a tap icon will flash and the hot water temperature will appear in the large house icon. once to lock the setting. If you do not press the the new setting will not be saved. It is not necessary to visit the hot water control on the boiler fascia to adjust the hot water setting; the room unit overrides the boiler setting. 9: Resetting the boiler: The OpenTherm Control can display a series of fault codes to assist the engineer or users in assessing its status. If a fault code does appear many will require the boiler to be reset. Should fault codes appear on the room unit the boiler can be reset from the receiver (which is usually located close to the boiler) by pressing the spanner, or at the boiler itself by turning the boiler main control selector past standby. The boiler cannot be reset from the room unit. All but one fault can be reset from the receiver however an A02 fault must be reset on the boiler fascia control by turning the main heating selector knob past standby. 10: Fault indicators on the receiver: If the green LED on the receiver is flashing the boiler is in lockout and requires resetting.

If the Amber LED on the receiver is flashing radio contact between the room unit and the receiver has been lost (it is therefore worth checking the battery indicator on the room unit). A solid red LED is not a fault indication, it simply indicates the unit is powered on. A solid amber LED indicates there is an external sensor fitted. 11: Fault codes on the OpenTherm control (room unit): Faults codes may be displayed on the room unit, but if the heating mode is OFF, no fault code is displayed. For further instructions relating to fault codes and system parameters, please refer to the OpenTherm Quick help guide on our website A01: Ignition fault on boiler A02: Boiler overheat * A03: Fan or flue problem A04: System water pressure too low A05: Electrical or boiler control board problem A06: Domestic hot water sensor problem (the boiler will still produce hot water for the user while showing this fault condition but using the flow thermistor will lock to 65 C which will provide warm water for washing only. The temperature will not be adjustable on the room unit until repaired). A07: Flow temperature fault A08: Return temperature fault A09: Flue temperature fault or service reminder (the boiler will still work as normal with a service reminder alarm indicated. * Any faults shown on the room unit with an A2XX code can be reset on the boiler control only, not at the receiver. 12: Setting the parameters on the OpenTherm Control: There are a set of default parameters ready programmed into the OpenTherm Control The adjustment should generally be by the engineer not the end user however there are two that the end user may need to adjust the heating curve and the value regarding the insulation of the property. To enter parameter or engineer mode. 5 times until PL appears in the screen

PASS will appear and flash in the screen and the display shows 00 Press and hold the until the 00 reads 53 53 is the password to enter parameter mode to scroll through the parameters. (When an adjustment is made pressing the again memorizes the new setting and moves on to the next parameter) The parameters are not numbered consecutively. It is strongly recommended the user does not adjust any of the parameters other than numbers 10 and 11. 01: Is to encode the receiver and room unit in case of failure and will rarely be necessary (if re-encoding is required refer to the instruction booklet that was supplied with the OT control. 08: Use the system. or s to adjust the maximum flow temperature you require for the heating 09: Use the or s to adjust the minimum flow temperature you require for the heating system 10: Use the or s to adjust the heating curve (we suggest a setting of 2.5 as a starting point. The default setting is 1.2) 11: Use the or s to adjust the OpenTherm Control to suit the insulation level of the property. The scale is 1 to 20 with 1 being a well-insulated house and 20 a poorly insulated house. The unit default is 10. 13: The room unit is set to display the actual temperature but if it is located in an unusual position, close to a window or over a radiator for example, it can be recalibrated while in this parameter with the or s. 14: If you wish to reset the control system to the factory default parameters use the the figure to 1. Then press the. to adjust 16: Indicates the software version of your OpenTherm Control 17: Use the or s allow the room unit to display in Centigrade or Fahrenheit. 18: Use the or s to adjust the temperature change upward from the programmed level necessary to switch the unit OFF (the hysteresis). The range is between 0.0 C and 2.0 C. Default is 0.1 C 19: Use the or s to adjust the temperature change downward necessary to switch the unit ON (the hysteresis). The range is between 0.0 C and 2.0 C. Default is 0.5 C 20: Use the or s to adjust the frost protection temperature. The range is between 3 C and 10 C. Default is 5 C 21: Fault memory. Use the or s to scroll through the last 9 faults recorded on the boiler.

22: Unused 23: Unused 24: Unused 26: Use the or s to swap between the display of the actual boiler flue temperature and the number of hours in condensing mode the boiler has operated x100. (2500 hours signals the need for a full service - A09 will be displayed on the room unit although the boiler will continue to operate as normal).