Installation guide for J4 Junction Box for R4 AIS Transponder System

Similar documents
RMS/RPX Reader. User Manual

UNC100 Integra Manual

KM300 Carbon Monoxide Detection System Installation Manual

Booster Power Supply Manual

TECHNICAL DATA SHEET CONVENTIONAL FIRE ALARM SYSTEMS Conventional Fire Alarm Control Panel

KT-100 Door Controller

MODEL EUR -5A AUTOMATIC SNOW/ICE MELTING SYSTEM CONTROL PANEL

4100U City and Relay Cards Installation Instructions

MODEL ZA-8N EIGHT ZONE ANNUNCIATOR FOR ALL MONITORING APPLICATIONS OUTSTANDING FEATURES

FIREFORCE 8 NOTIFICATION APPLIANCE CIRCUIT EXPANDER INSTALLATION & OPERATION MANUAL

Snifter ATEX22 VERSION. User Manual. Distributor

SCHMIDT LED Measured Value Display MD Instructions for Use

WM3000 WIRELESS MODULES

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

PTE0705 Electric Fence Monitor

Beacon 800 Gas Monitor Operator s Manual

4 & 8-POINT ANNUNCIATORS Instruction Manual

Power Supply Display Module PSDM. Installation and Operation Manual

ISOMETER IRDH375. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems)

User Guide

Interface Module RS232/485. INTERFACE MODULE RS232/485 Instruction Manual 03-INT-02-17

DC1136, DC1131-AA, DC1134-AA, DC1136-AA Input / Output modules

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

FireNET Plus Wiring Instructions

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

PERTRONIC INDUSTRIES LTD F4-RMAX Installation Note

DS 96/48 P. Digital indicator. Short manual 41/33-89 EN Rev. 00 DIM

Beacon 410A Gas Monitor Operator s Manual

FIRE ALARM CONTROL EQUIPMENT. Addendum October 2006 Instructions for new style EN54-4 Power supply unit module

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

Rev 7 06-APR MultiFlex Condensing Unit Board (CUB-II and CUB-TD) Installation and Operation Manual

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Model Gas Alarm Panel APPLICABILITY & EFFECTIVITY. This manual provides instructions for the following Sierra Monitor products:

1.7 A-ISOMETER IRDH575. RoHS. Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Pre-March 2016 Design - Click to be redirected to newer SBS-H2 design SBS-H2. Hydrogen Gas Detector Kit

Fire Control Panel FS4000

VA301C CONTROLLER WITH BACnet OPTION

General Routing Interface

SERVICE INSTRUCTIONS FOR. Fire Alarm System MINI-2000

OVEN INDUSTRIES, INC.

DGC-1000 DIGITAL GENSET CONTROLLER

Specification/ Data Sheet

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

FiberSensor Fiber Optic Intrusion Detection System (IDS)

ACCURATE ELECTRONICS INC

DTS SECURITY P.O.BOX 3399 Base plate-mounting EDENVALE instructions 1610 TELEPHONE

Ring Detect Relays. Model RDR. Installation & Operation. Ph: \ \

Installation, Operating and Maintenance Manual

AL3000 SERIES 100MM CHART MULTI-POINT TYPE HYBRID RECORDER

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

FP120-Z1 Power supply kit A (70 W) Technical Manual

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Door Release Power Supply

Combi B Alarm box. Mounting instructions

Networked Access Control Panel. Installation Guide

Element. Controller. Manual for use and maintenance. Element. Climate Controller. Ag/MIS/UMGB /17 Rev 1.0 P/N:

1.7. Insulation fault evaluators EDS460/490 EDS461/491

DGC-500 DIGITAL GENSET CONTROLLER

STATUS ALARM HISTORY ALARM RESET

AquiTron. AT-LDM Liquid Detection Module INSTALLATION INSTRUCTIONS

CO2Sensor Basic / ES 999

Installation Manual RINS1211-4

OPERATION AND INSTALLATION MANUAL

Controllers. Centralization of Access Control Devices Made Easy. Installer Guide

AH3000 SERIES 180MM CHART PEN TYPE HYBRID RECORDER

BC-4000 Bilge Monitor/Controller Installation Manual

Instruction Manual Model L2 RF Switch

Brivis Touch Controller. Installer Manual

MODEL ZAC ZONE ANNUNCIATOR/CONTROLLER DESIGNED FOR ZONE ANNUNCIATION AND MONITORING

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Operating instructions Safety-monitoring module SRB 302X3. 1 About this document

A36D/TPSD Modbus RTU (Serial) SCADA INTERFACE INSTRUCTIONS

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Operating instructions Safety-monitoring module SRB 302X3. 1. About this document. Content

EX41922 Hardened Unmanaged 2-port 10/100/1000BASE + 2-port 100/1000 SFP Ethernet Switch. User s Guide

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

5U Compact System. Installation Manual V1.0. Manufactured by Enatel Ltd. 321 Tuam Street PO Box Christchurch New Zealand

30.45 Electric Release PDRP-2001

Warranty Registration

Operating Instructions. For. Alarm Control Module. Model SSR 500

Model A2100 Series Annunciator

TB-200 CD-TB PRODUCT OVERVIEW. Product. Description. Specifications SKU: TB-200. Wiring. Battery Powered Thermostat

Fratech Multipath-IP

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Vocia VACIE. Reference Guide

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

Telecom Fuses. Benefits. Features. Applications

AutomationDirect PM24. Microprocessor - Based Process/Temperature Limit Controller. Operator s Manual. Technical Support.

GasScanner 8C. Eight Channel Monitor. Operator s Manual. MINT-0281-XX Rev. A 01/29/08

SBS-H2. Hydrogen Gas Detector Kit. For battery charging rooms and other areas where hydrogen gas may be present

VACIE REFERENCE GUIDE REVISION 1.2.6

Instruction Manual. Alarm Unit For Low Gas Level # Read manual before use! Observe all safety information! Keep manual for future use!

Beacon 200 Gas Monitor Operator s Manual

Installation Manual. Wiegand Interface Unit Four-State (WIU-4) North America T F Asia T F

Model 4001 Series Single Channel Controller

Transcription:

Saab TransponderTech Installation guide for J4 Junction Box for R4 AIS Transponder System Document id: 7000 108-033 B

COPYRIGHT Page i i COPYRIGHT The entire contents of this installation guide and its appendices, including any future updates and modifications, shall remain the property of Saab TransponderTech AB at all times. The contents must not, whether in its original form or modified, be wholly or partly copied or reproduced, nor used for any other purpose than the subject of this installation guide. Saab TransponderTech AB, SWEDEN ii DISCLAIMER While reasonable care has been exercised in the preparation of this installation guide, Saab TransponderTech AB shall incur no liability whatsoever based on the contents or lack of contents in the installation guide. iii VALIDITY OF THIS DOCUMENT This installation guide is valid for the J4 Junction Box.

CONTENTS Page ii CONTENTS 1 INTRODUCTION 1 1.1 About this installation guide 1 1.2 Unpacking the equipment 1 2 GENERAL INFORMATION 2 2.1 Physical Size (mm) 2 2.2 Cabling 2 2.3 Power Supply 2 2.4 Clearance area (mm) 3 2.5 J4 AIS Alarm Relay 3 3 MOUNTING THE BOX 4 3.1 Wiring Input/Output connections 4 3.1.1 RX Termination Resistance 5 4 TECHNICAL SPECIFICATIONS 6

INTRODUCTION Page 1 1 INTRODUCTION 1.1 About this installation guide This installation guide provides information to facilitate installation of the Saab TransponderTech J4 Junction Box for the R4 AIS Transponder System. As the J4 Junction Box is intended for use with the R4 AIS Transponder System, this installation guide contains information that is relevant for this type of installation. It is important to note that more details of the R4 AIS Transponder System installation are found in the R4 AIS Transponder System Installation Manual (included in the R4 AIS Transponder System Delivery Package). 1.2 Unpacking the equipment When unpacking the equipment, please check that the following is included in the delivered package, see also Figure 1. If any of the parts are missing, please contact the Saab TransponderTech dealer. Standard J4 package: Name Qty. J4 Unit 1 Mounting Screws (In plastic bag located 4 inside the box) Figure 1: J4 Junction Box

GENERAL INFORMATION Page 2 2 GENERAL INFORMATION 2.1 Physical Size (mm) 2.2 Cabling This guide details how to mount the standard cables that are included in the standard delivery package for the R4 AIS Transponder System. R4 Transponder Power Cable R4 Transponder Data Cable R4 Display Power Cable R4 Display Data Cable 2.3 Power Supply The R4 AIS Transponder System (transponder + display) is designed to operate on 24 volts DC. The nominal power used by the display and transponder is 25W. The J4 Junction Box shall be connected to an emergency power source. If connected to an emergency battery, a re-calculation must be made for the battery capacity. For power consumption of the R4 AIS Transponder System, see the R4 AIS Transponder System Installation Manual. The R4 Display shall be externally fused (slow blow fuse) with a 2 Amperes fuse. The R4 Transponder shall be externally fused (slow blow fuse) with a 4 Amperes fuse. To avoid power and voltage drops in the feed line it is important that sufficient size of cable is used. Note: The 6,3A fuse that is included in the J4 Junction Box, is a complement to the external fuses used.

GENERAL INFORMATION Page 3 2.4 Clearance area (mm) Leave a clearance around the J4 Junction Box to facilitate service and installation. See recommended clearance area below. 2.5 J4 AIS Alarm Relay The J4 AIS Alarm Relay (RE1) is included in the box, see Figure 2. It is required that the alarm output (relay) is connected to an audible alarm device or the ship s alarm system, if available. Alternatively, the ship s BIIT alarm system may use the alarm messages output on the AIS Presentation Interface (PI) provided the alarm system is AIS compatible.

MOUNTING THE BOX Page 4 3 MOUNTING THE BOX 1. Open the lid of the J4 Junction Box 2. Fix the box on an appropriate surface/place with the 4 supplied screws. Use the four holes that are located in each corner of the bottom plate. 3. Connect the cables to the terminal blocks, for connection details see Appendix A and other applicable sections of this document. 4. Clamp the cables to the clamp area located on the front of the box. (Clamps are not included). 5. Fix the lid to the box casing 6. If needed, also clamp the cable outside the box. 3.1 Wiring Input/Output connections A detailed installation-wiring diagram for the R4 AIS-System is available in Appendix A. The diagram includes cable connections for the R4 Display, the R4 Transponder, power supply, J4 alarm relay and RS422 ports. For a detailed description of the cable connections for the R4 Display and R4 Transponder, see the R4 AIS Transponder System Installation Manual. In Figure 2 an overview of the J4 circuit board is shown. A description of the included parts can be found in Table 1. Figure 2: Circuit Board Layout

MOUNTING THE BOX Page 5 Item K1 K2 K3 K4 K5 K6 Description Table 1: J4 Description of circuit board Terminal block for R4 Transponder Power Cable Terminal block for R4 Transponder Data Cable Terminal block for Pilot Port Terminal block for ECDIS Terminal block for Long Range Terminal block for R4 Display K7 Terminal block for Sensor 1, 2 and 3 K8 K9 K10 K11 JP1 JP2 JP3 JP4 Terminal block for Aux Port Terminal block for AIS Alarm Relay Terminal block for External 24VDC Input Power Terminal block for R4 Display Power Cable Jumper for RX Termination Resistance (240Ω) for Pilot Port Jumper for RX Termination Resistance (240Ω) for ECDIS Jumper for RX Termination Resistance (240Ω) for Long Range Jumper for RX Termination Resistance (240Ω) for R4 Display JP5 Jumper for RX Termination Resistance (240Ω) for Sensor 3 JP6 Jumper for RX Termination Resistance (240Ω) for Sensor 2 JP7 Jumper for RX Termination Resistance (240Ω) for Sensor 1 JP8 JP9 RE1 F1 Jumper for RX Termination Resistance (240Ω) for Aux Port Not used J4 Alarm Relay 6,3 A slow blow fuse 3.1.1 RX Termination Resistance Some installations may require that a termination resistance is connected to the incoming RX cable(s). All incoming RX to the J4 Junction Box has a jumper (J1-8) that makes it possible to Connected/Not Connect (NC) the termination resistance (240 Ω). The default setting is NC, jumper set to 2-3, see below. If the terminator resistance must be used the appropriate jumper should be set to position 1-2, i.e. the termination resistance is Connected. NC Connected 1 2 3 1 2 3

TECHNICAL SPECIFICATIONS Page 6 4 TECHNICAL SPECIFICATIONS PHYSICAL Dimensions: Height: 37 millimeters Width: 262 millimeters Depth: 130 millimeters Weight: 0.95 kilograms ENVIRONMENTAL Temperature: -15 C to +55 C (Operational) -55 C to +85 C (Storage) Vibrations: IEC 60945 ed. 4. EMC: IEC 60945 ed. 4 J4 AIS ALARM RELAY Max switching current: 3 A Max switching voltage: 250 VDC or 230 VAC Max switching power: 60W (DC) or 120 VA (AC) resistive load