Specifications. Table of contents. 2:Specification. 3:Composition. 4:Instruments outside figure

Similar documents
General Specifications

SPECIFICATION SHEET ORGANIC POLLUTION MONITOR. Model: OPM-410A - Organic Pollution Monitor - Issue: OPM-410A-0107-R0 Page 1 ISO ISO-9001

Certificate: / 29 April 2014

SPECIFICATION SHEET. SLC-1615 (for low concentration) SLC-1625 (for high concentration) SILICA ANALYZER

Furnace Gas Detector Head GD-A2400. Operating Manual (PT2-162)

Zirconia Oxygen Gas Analyzers

Customized Industrial Products

THEORY OR OPERATION 2 SENSOR UNIT - MECHANICAL 6 SENSOR UNIT - ELECTRICAL 8 CONTROL UNIT - MECHANICAL 9 CONTROL UNIT - ELECTRICAL 9 OPTIONS 11

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

PARTICULATE EMISSION MONITORING

Dust Concentration Meter

Standard Specifications

INSTRUCTION MANUAL FLOAT TYPE LEVEL SWITCHES HITROL CO., LTD.

Certificate: _01 / 22 March 2013

PRODUCT CONFORMITY CERTIFICATE

Models TX-KE and TX-KP Toxic Gas Transmitters

Oil-in-Water Monitoring. for. Marine and Industrial. Applications

Series Internal Detector

Membrane Technologies DMD Series Dryers ESM Series Dryers

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

OIL FILM DETECTOR (Long-distance correspondence Version)

Chemical Thermo-con. How to Order. Communication A RS-485 B RS-232C. Power supply 2 Single-phase: 180 to 242 VAC 50/60 Hz.

Certificate: / 9 February 2011

Standard Specifications

Product data sheet Palas Fidas 200 S

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

MULTI-POINT DENSITY ARRAY FIXED-POINT INTERFACE PROFILING MEASUREMENT

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

Buzzer Unit. TAN-5000 Series. Operating Manual

IN-SITU ZIRCONIA OXYGEN ANALYZER

industry revolves around VMMD Series Membrane Air Dryer

OPERATION MANUAL (Web Site Downloaded only)

Features and Benefits

Features and Benefits

CERTIFICATE. on Product Conformity (QAL 1) Number of Certificate: _02

General Specifications

Latest update: Ordinance of the Ministry of Internal Affairs and Communications No. 25 of March 27, 2013

Process Control PIP PCEA001 Fixed Gas Detection Guidelines

IN-SITU ZIRCONIA OXYGEN ANALYZER

CERTIFICATE of Product Conformity (QAL1 )

IN-SITU ZIRCONIA OXYGEN ANALYZER <HART communication>

Condumax II Hydrocarbon Dew-Point Analyzer

Air Resource Specialists, Inc.

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

4-20mA CYBER Cyber Transmitter for flammable, toxic and IR gas detection Cyber Head Increased security in ATEX certified head

LI-830 and LI-850 Gas Analyzers. For Continuous Monitoring Applications

HFID Heated Total Hydrocarbon Analyzer Module

MEMBRANE AIR DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution MEMBRANE AIR DRYERS

2-wire Passive Intelligent Loop (LED) Display Meter

Restek s Electronic Leak Detector

Compact Laser MBE system

ACCURATE ELECTRONICS INC

PRODUCT CONFORMITY CERTIFICATE

Class 1 laser beam sensor safe for your eyes

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

Key Features. General Description

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

Table of Contents. Check the LCLS Project website to verify 2 of 12 that this is the correct version prior to use.

Bristol Babcock Oil Content Monitor "oil in water"

BULLETIN: APPL-QAF-133R1

Contents. Outline of Product. Features of Product. Specifications of Product. Name and central function of section. Illustration of Terminal

Advantages / Characteristics

Ionizer Basic Fan Type ZJ-FA20. High-speed, High cost performance Ionization

MGD Gas Chromatograph

SPECIFICATIONS PARTICLE SENSOR KS-41B Higashimotomachi, Kokubunji, Tokyo , Japan

IR 3000 WBPi Online Moisture Measurement with Infrared Technology

for Drinking Water Systems

Advanced Ultraviolet Burner Controller

Certificate: _01 / 22 March 2013

Laser Particle Size Analyzer

Description Model Weil-McLain part number. Vent Termination Kit for 3" Stainless Steel All

Infrared Moisture Balance (FD-660)

Refrigeration Dryers TG TI Series

CMMD Series Membrane Air Dryer

Performance Specifications LSF LIFT-SMOKE-FREE

ultra-high purity compressed air dryers flow capacity: scfm ( Nm 3 /hr)

2-wire Passive Intelligent Loop (LED) Display Meter

Class 1 laser beam sensor safe for your eyes

JW SERIES. Three Phase Thyristor Regulator PSE-351

V A C U U M A N D P R E S S U R E T E C H N O L O G Y

Hot-air generator. Final edition of Electric hot-air generator!! Catalog No. 4 TAKETSUNA MANUFACTORY CO., LTD. Hot-air generator.

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

General Specifications

TUBE DRYERS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution TUBE DRYERS

Turbimax CUE21 / CUE22

CO 2 Laser. High Reliability and Performance

MODULAR COMPRESSED AIR PURIFICATION. ULTRAFILTER FRL.

CERTIFICATE of Product Conformity (QAL1)

GAW - WCCAP recommendation for aerosol drying

clean and quiet laboratory

Laser engraving & cutting machine installation. Operation Manual

SIMRAD GD10PE IR GAS DETECTOR

Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Safety vacuum drying oven for flammable solvents

Class 1 laser beam sensor safe for your eyes

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Using the DewTrak II Dew Point/ Humidity Transmitter

Transcription:

DUST DENSITY METER (DDM-2001) Specifications Table of contents 1:Outline 2:Specification 3:Composition 4:Instruments outside figure 1) Main body control box 2) Detector 3) Optical fiber cable 4) Purge air temperature control box

Tanaka electric laboratory Co., Ltd. 1.Outline This dust density meter (DDM-2001) is equipment which displays and automatic-measures dust density continuously as relative density by the light scattering method, and has the following features. 1-1 Merit (1) A detector is directly attached to chimney. This is the high sensitivity system which measures the amount of optical dispersion reflected in the dust particle, even when there is little dust density. (2) Since the detector is one unit, there are the following advantages compared with the thing of an optical penetration type. 1) Since the two-place construction by the side of transmission and receiving is unnecessary, a cost of construction ends at a low price. 2) A detector does not have worries about "a gap" of light axis by heat distortion. 3) Piping of purge air requires only one place. (3) Since it is separated from this dust density meter control box and the detector, there are the following advantages. 1) It is setting up the length of an optical fiber in 2-5m, and the control box installation to the place which is easy to maintain using the existing handrail and a scaffold is possible. 2) A detector can be installed in hot chimney because of the composition of only mechanism parts. An electronic circuit is protected from heat by detaching a control box in that case. (4) Since the synchronous detection system which used the light of fixed cycles is taken, it is not influent from other light sources. For this reason, measurement near the air opening part is also possible (5) Since the detector is purged by the special method, it has almost no adhesion of dust. Moreover, use under high temperature and high pressure can be performed according to peculiar structure. (Patent Now Showing) (6) Since a halogen lamp, a motor, etc. which are articles of consumption are using the general-purpose article, availability is good and comparatively simple also for the exchange work. (7) Range change, zero, and span adjustment can be performed also in operation. Moreover, zero adjustment can be performed to a constant cycle by being automatic. ( Just before value is held during zero adjustment)

(8) Various alarm points of contact, and state surveillance is made. (9) As an option, O2 conversion output and the moving average output are prepared. 1-2 Business Way (1) Tendency management Dust in the exhaust gas discharged from all combustion equipment is measured by relative density that carrying out continuation measurement For example, when got blocked and tear occur in a bag filter, since a dust density meter can measure at an early stage, it can prevent dust emitting to the atmosphere beforehand. (2) The present dust density can be known on real time By creating the correlation diagram of the amount of dust measurement between the output signal and the uniform drawing-in method (the JIS method), we can know the present dust density on real time. Thereby, operation management of EP and bag filter which observes dust density can be performed. 2. Specification 2-1 Control box (Type : DDM- 2001) (1) Structure Wall mount outdoor installation type (2) Principle 90 degree back ward light scattering method (3) Light source halogen light (4) Measurement range 0-1000mg/Nm3 relative density output (range is variable) (5) External output DC 4-20mA Isolated output (load resistance less than 750Ω ) RS-232C I/F output (a port is prepared) (6) Display Digital panel meter of 0-100% (7) Alarm / failure output 1 set-value alarm : It outputs in setting value over. 2 power supply shutdown alarm 3 failure of motor, lamp, internal power supply voltage, automatic zero adjustment (Dry a contact output : contact capacity : AC / DC 200 V, 0.1A) (8) Calibration 1Zero point adjustment. Automatic / manual change selection The execution cycle at the time of automatic selection is 7days or 30days 2Span adjustment. Optical fiber cables are connected to calibration box. Span adjustment with manual operation.

(9) Integration time variable range About 5 100 second (10) Temperature stability 1 meter display ± 2% / 10 2 external output ± 2% / 10 (11) Long time stability ±2% / 1 week (12) Power supply AC100V±10% (50Hz), 4A (13) Circumference temperature -10~+50 (14) Outside size 500 x 670 x 270mm (15) Weight Approx. 45kg (16) Finish painting color Munsel 5Y7/1 G=40 Powder coating 2-2 Optical fiber cable set (1) Diameter of bundle / Length 5.6φ 2m~5m (based on specification) (2) Structure With the flexible guard made from stainless steel with PVC covering. Covering heat resistance temperature 60 (3) Operating temperature (bundle part) Continuation use temperature 200 (300 of instants are good) However 350 continuation use is possible by connecting to the detector. Purge air cools optical fiber cables in the detector (4) Bundle part materials 1 transmitting Aluminum / stainless steel 2 receiving Delrin / stainless steel 2-3 Detector (1) Size 260 x 125 mm (2) Weight Approx. 5kg (3) Material Stainless steel (SUS304 ) (4) Surface treatment Measurement part: heat resistance paint (5) Structure Peculiar air purge structure by silica glass. (6) Attachment 200 x 65 mm rectangle hole is opened and attached to the duct. Please give the flange of an attachment part as construction side preparation. The packing between flange-detector is standard appending. (7) Connection of purge air Female screw of PT 1/4 (cheese union) (8) Patent Now Showing in Japan (Provisional Publication No. 9-236545)

2-4 Calibration box (1) Size 30 x 30 x 130mm (2) Structure It has the fixed amount of penetrations by small holed diaphragm and polarizing filter. Small holed diaphragm and polarizing filter are set up at the time of real operation. 2-5 Purge air temperature control box (1) Size 530 x 500 x 220 mm (2) Weight Approx. 26kg (3) Finish painting color Munsel 5Y7/1 G=40 (4) Installation restrictions Please supply instrumentation air or pure compressor air. (5) Structure Purge air from compressor in site is breathed out from detector head.. In order to prevent that the detector s silica glass becomes cloudy with dew condensation by the moisture in purge air, this air is pressurized and heated at a built-in air pressure heater. And oil-mist in purge air is simultaneously removing by ceramic filter. (6) Required air flow 120 l/min ( it can do few according to the adhesion state of dust.) (7) Air pressure More than +50KPa (0.5 kg/cm2) process gas pressure (8)Purge air temperature 80 (9) Power supply AC200V Capacity 1kVA 2-6 Pump built-in type purge air temperature control box (Option) (1) Size 600 x 500 x 300 mm (2) Weight Approx. 45kg (3) Finish painting color Munsel 5Y7/1 G=40 (4) Purpose It is used when purge air cannot prepare in the site. (5) Installation restrictions This unit is able to use in case of that process gas pressure is of the same grade as atmospheric pressure or when it is minus pressure (6) Structure Purge air exhausted from dry pump is breathed out from detector head.. In order to prevent that the detector s silica glass becomes cloudy with dew condensation by the moisture in purge air, this air is pressurized and heated at a built-in air pressure heater. And mist in purge air is simultaneously removing by ceramic filter. (7) Air flow Approx. 120 l/min

(8) Purge air temperature 80 (9) Power supply AC200V Capacity 1.2Kva 3.Composition Please refer to the composition figure of the following page. (1) Control box (Type : DDM- 2001) It consists of power supply circuit, light source equipment, light receiving circuit, signal processing circuit of CPU. The heat exchanger is built in as a measure against temperature by outdoor installation. (2) Detector It is attached to the duct or chimney in order to measure dust density. The optical fiber cables from control box are connected. Since this detector has the structure of dividing inside and outside of duct with silica glass (3mm of board thickness), span calibration is possible under high temperature and high pressure exhaust gas by removing optical fiber cables safely. (3) Transmitting optical fiber cable The light (halogen light) of fixed cycle made with the light source equipment in control box is sent to detector through this optical fiber. (4) Receiving optical fiber cable The scattering light by dust is sent to the light receiving circuit in control box through this optical fiber (5) Calibration box Remove optical fiber cables from detector and connect to this calibration box. And decide Span adjustment value. (This calibration box is set up during real operation there) (6) Purge air temperature control box In order to prevent that the detector s silica glass becomes cloudy with dew condensation by the moisture in purge air, this air is pressurized and heated at a built-in air pressure heater. And oil-mist in purge air is simultaneously removing by ceramic filter.