Multi Zone Air Conditioner SVC MANUAL (Exploded View)

Similar documents
Multi Zone Air Conditioner SVC MANUAL (Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

(60Hz/R410A) 6CIM0-02B (Replace: 6CIM0-02A)

Wall Mounted Air Conditioner SVC MANUAL(Exploded View)

Hydro Kit (For Medium Temperature) SVC MANUAL(Exploded View)

Air Conditioner SVC MANUAL(Exploded View)

LG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static)

Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

SVC Manual(Exploded View)

Single Zone Air Conditioner SVC MANUAL (Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

SVC Manual(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Single Zone Air Conditioner SVC MANUAL(General)

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F)

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01J (Replace: 5BPM0-01H)

Ductless Split Systems Wall-mounted, Multizone Heat Pump

Ductless Split Systems Ceiling Cassette Heat Pumps

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

duct-free air conditioning systems Art cool inverter flex multi-split

Ductless Split Systems Concealed Duct Heat Pumps

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

AUS-DU112. New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 2766 PH : FAX :

ENGiNEERiNG AND SPECiFiCATioNS GuiDE

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

CU-B24DBE5 CS-F28DTE5 CU-B28DBE5 CS-F28DTE5 CU-B28DBE8 CS-F34DTE5 CU-B34DBE5 CS-F34DTE5 CU- B34DBE8 CS-F43DTE5 CU-B43DBE8 CS-F50DTE5 CU-B50DBE8,

Ceiling Cassette Type Single-Zone Air Conditioning

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

ENGiNEERiNG AND SPECiFiCATiONS GuiDE

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

(Non-Inverter & Inverter) R410A

Air Conditioner CONTENTS

Service Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C

SINGLE-ZONE CEILING-CONCEALED DUCTED SYSTEM ENGINEERING MANUAL

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

Kühl J Series DUCTLESS ROOM AIR CONDITIONERS THE EXPERTS IN ROOM AIR CONDITIONING. Wall-mounted Ceiling Cassette The Insider Concealed Ducted

AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-02A(5BPU0-01A)

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-03A(Replace:5BPU0-02A)

Heat Pump Air Conditioning Systems

A single answer for multiple zones.

DESIGN & TECHNICAL MANUAL

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

Just feel well. 2017/2018 Air conditioning

Highly Efficient,Powerful Heating and Cooling.

Samsung 360 Cassette, Single Zone, Split System

J SERIES DUCTLESS SPLIT SYSTEMS

Room Air Conditioner Service and Parts Manual

Multi Air Conditioner Indoor Unit SVC MANUAL(General)

DESIGN & TECHNICAL MANUAL

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

A single answer for multiple zones.

Single-Zone Four-Way Ceiling-Cassette System Engineering Manual

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

DESIGN & TECHNICAL MANUAL

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

Up to SEER 26.1 Wall Mount Heat Pump

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Breeze A revolution in room cooling.

Geniuses at work. Residential Mini Splits

Easy to service. Up to 9 indoor units can be connected

LV Series. SEER 15+ Concealed Built in Heat Pump

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Single "A" Air Conditioner SVC MANUAL(General)

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

DUCTLESS SPLIT SYSTEMS

Room Air Conditioner CONTENTS CS-E9BKP CU-E9BKP5 CS-E12BKP CU-E12BKP5. Order No: MAC C2

DUCTLESS ROOM AIR CONDITIONERS

Residential and Light Commercial Ductless Systems Catalog

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

DESIGN & TECHNICAL MANUAL

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

SERVICE Manual FREE JOINT MULTI AIR CONDITIONER

RC-0219-A. Single-Split Non Inverter Series

Wall Mounted Split Systems

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr

Ductless SPLIT SYSTEMS. cool only HEAT PUMPS

DESIGN & TECHNICAL MANUAL

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

Transcription:

Multi Zone Air Conditioner SVC MANUAL (Exploded View) CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual. nly for authorized service personnel. MDEL: MD18Y3JM 960-920-07

1. Specification Indoor unit type Model Ceiling Concealed Duct - Low Static MD18Y3JM Power Supply Ø / V / Hz 1/ 208~230/ 60 Capacity(*) Btu/h class 18,000 Current Running Current A 0.25 Fan Motor Type BLDC Fan Type Sirocco Fan Motor utput(w) x No. of Unit 19 x 2 Air Flow Rate CMM 15/ 13.5/ 11.5 (H / M / L) CFM 530/ 477/ 406 External Static Pressure mmaq 4 Capacitor μf / Vac - Drive Direct Drive Coil Row x Column x FPI 2R x 11C x 21 Dimensions Body mm(inch) 1,100 x 190 x 575 (43 5/16 x 7 15/32 x 22 21/32) (W x H x D) Decorative Panel mm(inch) - Net Weight Body kg (lbs) 26.5 (58.4) Decorative Panel kg (lbs) - Air Filter Long life filter Sound Level (H / M / L) db(a)+3 34/ 31/ 29 Piping Liquid mm (inch) 6.35 (1/4) Connections Gas mm (inch) 12.7 (1/2) Drain(D/ID) mm(inch) 32 / 25(1.26/0.984) Dehumidification Rate l/h 2 Safety Devices Fuse, thermal protector for fan motor Temperature Sensor Thermistor Refrigerant R410A Refrigerant Control EEV(in utdoor unit) Transmission Interunit Cable No. x AWG 418(Including Earth) Note: 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 26.7 C(80 F) DB/19.4 C(67 F) - utdoor Temperature 35 C(95 F) DB/23.9 C(75 F) Heating: - Indoor Temperature 21.1 C(70 F) DB/15.6 C(60 F) WB - utdoor Temperature 8.3 C(47 F) DB/6.1 C(43 F) WB Piping Length - Interconnecting Piping Length 7.5m(24.6 ft.) - Level Difference of Zero 2. Wiring cable size must comply with the applicable local and national code. 3. The specification may be subject to change without prior notice for purpose of improvement. 4. For more Capacity(*),refer to the combination table Conversion Formula kw = Btu/h class 0.0002931 cfm = CMM x 35.3-2 -

2. Function Table Air flow Category Function MD18Y3JM Air purifying Installation Reliability Convenience Individual control CAC network function Air supply outlet 1 Airflow direction control(left & right) - Airflow direction control(up & down) - Auto swing(left & right) - Auto swing(up & down) - Airflow steps(fan / cool / heat) 3 / 3 / 3 Chaos swing - Chaos wind(auto wind) Surge cool(power wind) Swirl wind Deodorizing filter Plasma air purifier Prefilter(washable / anti-fungus) Drain pump E.S.P. control Electric heater(operation) High ceiling operation - Hot start Self-diagnosis Soft dry operation Auto changeover Auto cleaning Auto operation(artificial intelligence) Auto restart operation Child lock Energy-Saving Cooling Mode Forced operation Group control Sleep mode Timer(on/off) Timer(weekly) Two thermistor control Wide wired remote controller DWC1 Deluxe wired remote controller - Simple wired remote controller Simple wired remote controller(for hotel use) Wireless remote controller(simple) Wireless LCD remote control Wireless LCD remote control(ez) General central controller (Non LGAP) Dry contact Central control(lgap) PDI(power distribution indicator) PI 485 CTIE Zone control Special function kit thers Thermistor - : Applied : Not applied : No relation ption : Model name & price are different according to options, and assembled in factory with main unit. Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. - 3 -

3. Piping Diagrams Heating Heat exchanger Gas pipe connection port (flare connection) Cooling M Th3 Th1 Sirocco Fan Th2 Liquid pipe connection port (flare connection) LC. Description PCB Connector Th1 Thermistor for suction air temperature CN_RM Th2 Thermistor for evaporator inlet temperature CN_PIPE/IN Th3 Thermistor for evaporator outlet temperature CN_PIPE/UT - 4 -

4. Wiring Diagrams CN_REM CN_PIPE/IN CN_PIPE/UT CN_RM CN_D/PUMP CN_PWER CN_CC CN_DISPLAY CN_PTIN CN_FLAT CN_MTR1 CN_MTR2-5 -

FAN SPEED TEMP PER MDE 5. Exploded View W4811B W3110 263230B 159830 263230C 336600B 130911 349610 346810B 359012A 147901 249951 268711C 263230A 336600A W6640 359012B 268711E 267110 354210 352118A W51620 330871 352118B 158591 352150 437213 137211-6 -

Model: MD18Y3JM Loc No. Description Friedrich Part # 147901 Barrier,Indoor 67600403 W4811B Bracket Assembly 67600703 349610 Bracket Assembly,Motor(Indoor) 67600708 130911 Cabinet Assembly,Indoor 67600809 W3110 Case 67600925 249951 Case Assembly,Control(Indoor) 67600904 W6640 Connector,Terminal Block 67601407 354210 Evaporator Assembly,First 67602010 359012A Fan Assembly,Blower 67602103 359012B Fan Assembly,Blower 67602105 159830 Filter Assembly,Air Cleaner 67602201 352150 Hose Assembly,Drain 67602801 336600A Housing,Wrapper 67602903 336600B Housing,Wrapper 67602904 346810B Motor Assembly,DC,Indoor 67603310 346810B Motor,DC 67603331 330871 Pan Assembly,Drain 67603703 137211 Panel Assembly,Front(Indoor) 67603801 437213 Panel Assembly,Rear(Indoor) 67603816 268711C PCB Assembly,Main 67603908 268711E PCB Assembly,ption 67603918 158591 Pump Assembly,Water 67604100 267110 Remote Controller Assembly 67604300 W51620 Socket,Flare 67604401 263230C Thermistor Assembly,NTC 67604805 263230A Thermistor Assembly,NTC 67604809 263230B Thermistor Assembly,NTC 67604822 263230A Thermistor,NTC 67604825 263230C Thermistor,NTC 67604827 352118A Tube Assembly,Menifold(Indoor) 67606002 352118B Tube Assembly,Menifold(Indoor) 67606006

Friedrich Air Conditioning Co. I 10001 Reunion Place, Suite 500 I San Antonio, T 78216 I 877.599.5665 www.friedrich.com