Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

Similar documents
Brawa-Mix Thermostatic mixing valves

Unibox Individual room temperature control and limitation of return temperature in surface heating systems

Valves, controls + systems Flow, pressure and temperature balancing

Valves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved.

Control valves for floor heating systems. Floor Heating Manifolds

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

HERZ Differential Pressure Control Valve 4002

Thermostatic valves with radiator connection systems

Mikrotherm. Manual Radiator Valves With presetting

HERZ Regulating valve 4002

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

DEVIATING VALVES ART K063

Multilux 4-Eclipse-Set

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

Regulux. Radiator lockshield with drain-off facility. To be precise.

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

Standard. thermostatic valve body without presetting

Vekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

Automatic balancing valves ASV-PV (new generation) DN 32-50

TS RD 7761 RD, 7761 RD

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

Radiator valve inserts

ThermoDual Domestic hot water charging system

Flush individual room control for floor heating systems

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

Multibox 4. Floor Heating Controller Flush individual room control for floor heating systems with supply shut-off

1592P01. for liquids in piping DN max. DC 48 V, 1 A, 20 W

Thermostatic mixing valves with replaceable cartridge for centralized systems

Valves, controls + systems. Regucor WHS Energy storage centre. Innovation + Quality. Product range. v o. Awards: i y. n n

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

Multibox. Floor Heating Controller Flush individual room control for floor heating systems

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Metering systems 0548EN April 2014

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Minimalist Bottom Outlet Thermostatic Bar Shower. Telephone Product Specification

HERZ-Thermostatic and Return Valves. DE LUXE Edition 1000 (0999) HERZ Armaturen. Standard Sheet for DE LUXE. Richard-Strauss-Straße 22 A-1230 Wien

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

Partner Valve/High Quality Ball Valve LENO MSV-S

CALIS-TS-3-D. HERZ Armaturen. Standard Sheet for 7745, 7746, 7761 Edition 0700 (0999) Three-Way Valves in 3-D Design for One-Pipe Systems

RA2000 Commercial TRVs

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

Thermostatic valve bodies

Innovation + Quality. Product range. Awards:

Say heating. Say Herz. HERZ-Supply Engineering

Thermostatic head with wax sensor

SOLUTIONS GUIDE. For total efficiency

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Mira Reflex Thermostatic Bar Valve

INSTRUCTIONS REHAU PRO-BALANCE MIXING MODULE

TRV 300 RADIATOR VALVES

1592P01. for liquids in piping DN

Installation, Operating and Maintenance Guide

Radiator Valve Program

CONTROL UNIT FOR UNDERFLOOR HEATING SYSTEMS

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.

thermostatic valve body with stepless precision presetting

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

Thermostatic mixing valves with interchangeable cartridges

MADE IN GERMANY. Valves, controls + systems Thermal solar energy Stations, controllers, collectors, accessories, service, software

THERMOSTATIC EXPANSION VALVES AND THERMOSTAT CONTROL DEVICES

Thermostatic valve bodies

Solar station DKP 6-8 / DKP Installation and Service Manual C

manifold, for radiators

Heating Controls Thermostatic and Manual Radiator Valve range

Installation Instructions

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

TA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water

Multibox. Flush Individual Room Control for Floor Heating Systems. To be precise.

PLEASE LEAVE THIS MANUAL WITH THE OSO UNIT AFTER INSTALLATION INSTALLATION MANUAL

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

MIX2 - MIX3 MIX2 MIX3 COMPONENTS DESCRIPTION DIMENSIONS

IMI Heimeier Kit Hydroca ble

CATALOGUE NUMBERS. Pressure Reducing Valve (PRV)** Mains Supply. Cold Water Outlets

Installation and operating instructions

product overview ProControl

Powerstock Storage Tank

Installation, Operation and Maintenance Instructions for Thermax Semi-Storage Calorifier

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

Transcription:

Thermostatic valve with adjustable temperature control range Technical information Tender specification: Oventrop thermostatic valve Aquastrom T plus with presetting for circulation pipes. Thermal control : Recommended control range: 55 C up to 60 C (Max. control range: 40 C up to 65 C; control accuracy: ± 1 C). The valve automatically supports thermal disinfection. The volume flow is increased at about 6 K above the set temperature and is reduced - irrespective of the set temperature - to the residual volume flow when exceeding a temperature of 73 C. The valve thus guarantees an optimum thermal disinfection in the circulation system. The max. volume flow may be preset and isolated irrespective of the set control temperature. The valve is equipped with a draining valve for hose connection which allows to drain the circulation riser for maintenance. The temperature can be monitored with the help of a thermometer or a temperature sensor. The temperature setting can be secured with the help of a lockshield cap. The set temperature can still be read off. The temperature controller does not come into contact with the fluid; all components in contact with the fluid free from brass; body made of bronze; O-rings made of EPDM, without dead zone. Technical data: Max. operating temperature: 90 C Nominal pressure: 16 bar Factory settings: Temperature 57 C Set volume flow DN 15: 2.0 DN 20: 3.0 DN 25: 4.0 Advantages: automatic thermal control of the volume flow support of thermal disinfection volume flow increases at about 6 K above the set temperature, therefore disinfection temperature in the riser is reached quickly volume flow is limited when exceeding a temperature of 73 C to guarantee thermal disinfection of succeeding plant components corrosion-resistant due to bronze material temperature setting can be read off even with mounted lockshield cap body with hole for lead sealing temperature monitoring with the help of a thermometer or a sensor element (accessory) via a centralised building control system presetting of the max. volume flow irrespective of the set control temperature and isolation for maintenance integrated draining valve for hose connection without dead zone DVGW, SVGW, KIWA, and ACS certified Aquastrom T plus D H 2 Item no.: DN H 2 D 4206504 15 110 188 83 96 100 142 G 3 4 4206506 20 123 188 83 96 100 142 G 1 4206508 25 133 188 83 98 100 142 G 1 1 4 Ø D H2 D H 2 SW Item no.: DN Ø D H 2 SW* 4205552 15 15 115 188 83 96 100 142 27 4205553 15 18 115 188 83 96 100 142 27 4205554 20 22 130 188 83 96 100 142 32 4205555 25 28 140 188 83 98 100 142 41 Item no.: DN H 2 D SW* 4205504 15 110 188 83 96 100 142 G 3 4 27 4205506 20 123 188 83 96 100 142 G 1 32 4205508 25 133 188 83 98 100 142 G 1 1 4 41 Dimensions *SW = Spanner size 1 2016 Oventrop

Installation advice: The valve is to be installed in the correct direction of flow (see arrow on the body). Setting of the nominal temperature value: Pull off the lockshield cap. Turn the handwheel of the temperature control unit until the required temperature value on the scale is in line with the marking on the valve body. Recommended temperature range: 55 C - 60 C Factory setting: 57 C Refit the lockshield cap by pushing the slit of the lockshield cap over the marking ridge at the valve body. The set temperature value can be read off through the viewer even with mounted lockshield cap. The temperature setting can be secured. To do so, the lockshield cap is secured by leading the sealing wire through the hole at the valve body. Modification of the limitation of the set maximum volume flow: Setting is carried out at the throttling valve installed behind the control unit. The throttling valve may also be used for isolation. The required presetting values can be obtained from chart 3. All intermediate values are infinitely adjustable. Factory setting: DN 15: 2.0 DN 20: 3.0 DN 25: 4.0 Temperature setting The chosen presetting can be read off two scales (basic setting = longitudinal scale, fine setting = peripheral scale, see illustr.). The limit stop of the presetting is even kept if the throttling valve is closed for maintenance. Presetting: 1. The presetting value at the throttling valve is set by turning the handwheel. a. The display of the basic setting is shown by the longitudinal scale together with the sliding indicator. b. The display of the fine setting is shown by the peripheral scale on the handwheel together with the marking. The subdivisions of the peripheral scale correspond to 1 10 th of a half turn of the handwheel. 2. Limitation of the set presetting value by turning the inner adjustment stem clockwise until it seats. This can be done by using a screwdriver with a 3 to 4 mm blade width. 3. The presetting value can be locked with the help of a locking pin (accessory). Information regarding installation of accessories: The thermostatic valve Aquastrom T plus can be integrated into an existing centralised building control system with the help of a sensor element PT 1000 which may be installed subsequently. To do so, the thermometer is removed and is replaced with the sensor element Sensor LW TQ PT 1000 (accessory, item no. 4205592). Accessory: Item no.: Thermometer 20 C - 100 C 4205591 Sensor LW TQ PT1000 sensor element for centralised building control system 4205592 Replacement draining valve 4205593 Insulation shell for DN 15 / DN 20 4205581 Insulation shell for DN 25 4205583 Locking pin with sealing wire for volume flow limitation 1061792 Lead sealing set 1089091 Volume flow setting Sliding indicator Basic setting scale (longitudinal scale) Handwheel Marking Fine setting scale (peripheral scale) Hole for sealing wire Handwheel Locking pin Hole for sealing wire 2016 Oventrop 2

Description of thermal regulation behaviour: The thermal regulation behaviour of the circulation valve is described in chart 1. During normal operation (temperature range up to 65 C), the circulation valve limits the volume flow derived from the nominal temperature to the set residual volume flow. Adjustable control range 40 C 65 C Recommended control range 55 C 60 C Disinfection range > 70 C Volume fllow [l/h] Disinfection volume flow Residual volume flow Potable water [ C] Chart 1 Valve limits the volume flow at the set nominal temperature value to a residual volume flow With the temperature rising during the disinfection process, the Oventrop valve Aquastrom T plus allows for a higher volume flow when the set control temperature is exceeded by approx. 6 K. When reaching a temperature of approx. 73 C, the volume flow is decreased to the minimum volume flow. As a result, a higher differential pressure is reached in the corresponding riser and thermal disinfection in the succeeding risers is accelerated. This way, the disinfection temperature within these pipes is reached faster than within pipes which are not hydraulically supported during the disinfection process. As a result, significant energy savings can be made. Once the disinfection process has been completed, the water temperature drops, the Aquastrom T plus returns to normal operation and the temperature returns to the set nominal value. Valve opens approx. 6 C after having reached the minimum residual volume flow Having reached a temperature of 73 C, the valve limits the volume flow to the residual volume flow again Limitation of the volume flow: The maximum volume flow (which is situated in front of the set nominal temperature value in chart 2) can be limited with the help of the circulation valve Aquastrom T plus. This allows for the hydronic balancing of the circulation pipes especially in case of a strong temperature drop, for instance in case of a boiler breakdown or an excessive water consumption. The volume flow is limited within the set flow range by the temperature regulation according to the regulation characteristics shown in chart 2. The flow values and the corresponding presetting values can be obtained from chart 3. Volume fllow [l/h] Presetting 6 Presetting 5 Presetting 4 Presetting 3 Presetting 2 Presetting 1 Set nominal temperature value Water temperature [ C] Chart 2 3 2016 Oventrop

Description: The immediate supply of hot water to the draw off points of a potable water network is realised by the distribution of the hot water from the potable water heater to one or several circulation risers. Each circulation riser feeds the hot water to the draw off points via a supply pipe which is connected to the main riser and the water is fed back to the potable water heater via a return pipe. The contractor is responsible for the design of such water networks. He has to observe the hydronic conditions within these pipe networks in order to ensure that a sufficient temperature is maintained in all circulation risers. The pipework conditions must guarantee that a noxious concentration of pathogenic germs (especially legionella) is avoided. On the one hand, the hydronic conditions are determined by the flow loss in the pipework of the circulation risers and on the other hand by the heat loss of hot water when flowing through the circulation pipes. This heat loss depends on different parameters (pipe length and dimension, insulation, ambient and pipe temperature) and has to be considered individually for each system. To compensate the heat loss and to keep the temperature high enough, a certain volume flow, or strictly speaking, a certain heat flow has to pass through the circulation pipe. For this reason, a larger hot water quantity has to flow through the circulation risers which are located far away for the potable water heater than through the risers at a nearer location. This is achieved by a limitation of the volume flow in the nearer circulation pipes by building up a corresponding differential pressure with the help of regulating valves. The calculation of a circulation pipe within a domestic water installation can only be made approximately for stationary operating (without draining hot water). As the withdrawal quantities vary at the different draw off points (bathroom, kitchen etc.) during normal operation, the water quantity required to maintain the circulation pipe is also varying continuously. An optimum adaptation to these changing hydronic conditions is guaranteed by the automatic thermostatic regulating valves Aquastrom T plus. The following models of the Aquastrom T plus valve are also available: With isolation facility, presettable, but without draining valve for hose connection, without thermometer and without insulation. Models: Item no.: both ports male thread, flat sealing, according to DIN ISO 228 DN 15 G 3 4 x G 3 4 4206604 DN 20 G 1 x G 1 4206606 DN 25 G 1 1 4 x G 1 1 4 4206608 both ports female thread according to EN 10226 DN 15 Rp 1 2 x Rp 1 2 4205604 DN 20 Rp 3 4 x Rp 3 4 4205606 DN 25 Rp 1 x Rp 1 4205608 Draining orifice G 1 4 in front of the thermal control unit closed with a plug. Dimensions as item no. 42055/65 (page 1). Installation advice: The valve is to be installed in the correct direction of flow (see arrow on the body). 2016 Oventrop 4

t setting 2.0 Chart 3 measured at a temperature of 20 C Aquastrom T plus DN 15 measured at a presetting value of 2.0 setting 3.0 setting 4.0 Aquastrom T plus DN 20 measured at a presetting value of 3.0 Aquastrom T plus DN 25 measured at a presetting value of 4.0 Residual volume flow at presetting: Presetting k v kv at 2 K P-deviation DN 15 2.0 0.11 0.31 DN 20 3.0 0.31 0.44 DN 25 4.0 0.42 0.60 Subject to technical modifications without notice. Product range 12 Gedruckt auf chlorfrei ti 130-EN/5/MW gebleichtem Papier. Edition 2016 5 2016 Oventrop