PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING

Similar documents
R557R EN January 2012

Thermostatic head with wax sensor

Radiators: indirect energy metering and components

Metering systems 0548EN April 2014

GENERAL CATALOGUE MICROMETRIC, THERMOSTATIC VALVES THERMOSTATIC VALVES MANUAL VALVES LOCKSHIELDS ACCESSORIES AND SPARE PARTS

Boiler room components 0463EN October 2013

CALEFFI. Set point thermostatic regulating unit. 182 series 01190/18 GB. replaces dp 01190/15 GB

Systems for central heating

Mercury Mixing Kit (Code: ME1053)

RADIANT PANEL SYSTEM CONTROL QUICK GUIDE

MIX2 - MIX3 MIX2 MIX3 COMPONENTS DESCRIPTION DIMENSIONS

CALEFFI. Thermostatic regulating unit for heating systems. 166 series 01238/17 GB. replaces dp 01238/15 GB. Function

ACCREDITED. Product range Code A2L Pre-assembled set point temperature regulating unit with manifolds and box, with UPM3 Auto L pump

Data Sheet. Compact Mixing Shunt for Floor Heating, FHM-Cx. Application:

THERMOSTATIC SINGLE-PIPE AND DOUBLE-PIPE VALVES

FHM-Cx Mixing Shunts for Floor Heating

Technical Product Guide

Pivot Stove Hydronic Installation Guide

CALEFFI. Modulating temperature regulating unit for heating and cooling with high temperature distribution kit. series /04 GB.

Installation and Commissioning Instructions FMU3 Floor Mixing Unit with Grundfos UPM3 Pump

HEATING AND COOLING UNDERFLOOR SYSTEM

CALEFFI. SATK wall-mounted heat interface unit Fitted for connection to DHW storage. SATK40 series 01216/14 GB

V-exact II. Thermostatic Radiator Valves Thermostatic valve body with stepless precision presetting

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Air treatment units 0932EN October 2017 Dehumidifier unit for radiant systems Flush-mounting installation in false ceilings

R586R. Distribution and Regulation units. Datasheet 0861EN 04/2019 R586RY103 R586RY102 R586RY101 R586RY104

Function series Thermo-electric actuator electric supply 230 V (ac) or 24 V (ac/dc)

Thermostatic valves with radiator connection systems

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Multilux 4-Eclipse-Set

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

CONTROL PANEL. RIELLOtech PRIME ACS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Control valves for floor heating systems. Floor Heating Manifolds

Radiator Valve Program

CONTROL UNIT FOR UNDERFLOOR HEATING SYSTEMS

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Installation and operation manual for mixing modules FH-MJB and FH-MJC

TRV & Lockshield Pack Angle Pattern Thermostatic Radiator Valve Vertical or horizontal mounting with (367 CPLS) matching lockshield

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

4-way valve with thermostatic option with variable centre distance and pre-adjustment for Single pipe and Dual pipe systems.

Product overview All you need to know about choosing valves and thermostats

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

PTG series valves 0490EN June 2018 Valves with thermostatic option for radiators, with presetting

HEATING PRODUCTS P R I C E L I S T

Convertible radiator valve for one-pipe systems, centre distance 35 mm

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

BOILING UNIT REDITAP. Installation and User Guide. IMPORTANT: This booklet should be left with the user after installation and demonstration

Straight pattern thermostatic radiator valve vertical or horizontal mounting with (368T CPDLS) matching drain off lockshield

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

CALEFFI. Thermostatic mixing valves, low-lead, high-flow series 01256/18 NA. Replaces 01256/15 NA

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

RA2000 Commercial TRVs

Metering systems 0371EN July 2016 User satellites, GE556 series Versions GE556Y301, GE556Y302

HERZ TS-3000 HERZ HERZ Armaturen A-1230 Vienna Richard-Strauss-Straße 22

CALEFFI. Anti-condensation circulation unit. 282 series 01225/14 GB. replaces dp 01225/11. Code completion Setting 45 C 55 C 60 C 70 C.

THERMOSTATIC RADIATOR VALVES FOR IRON, COPPER, POLYETHYLENE AND MULTILAYER PIPE PRODUCTION RANGE IRON PIPE CODE CONNECTION

Product range Code HE1 Connection and energy management compact unit without anti-condensation valve

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

CODE MODEL TYPE PRESS 60 N 616 T PRESS 60 N 616 T80

thermostatic valve body with stepless precision presetting

Thermostatic Radiator Valves (Caleffi)

Installation instructions. Pump Group. For wall hung gas-fired condensing boiler GB162-50/65/80/ TD UK/IE (2014/09)

FHM-Cx Mixing Shunts for Floor Heating

Technote. Frese AquaHeat HW - DH. Application. Design. Features and Benefit. Operation. Optional.

Installation and Commissioning Instructions

Danfoss prefabricated floorheatingunit Type FH-G/FH-GS/FH-GR/FH-GRS

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

manifold, for radiators

Technical Helpline. Installation Manual. WHS-M-S3-Series Manifolds. Hydronic Heating System

Connection set. Radiator connection set for thermostatic and manual operation Ø 12

Standard. thermostatic valve body without presetting

Dynamic thermostatic radiator valves DYNAMICAL

SOLUTIONS GUIDE. For total efficiency

Amptec. Electric flow boiler

Calypso TRV-3. (for the Nordic countries) Thermostatic radiator valves With presetting

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Thermostatic head K. with contact or immersion sensor. Thermostat-Köpfe For medium temperature control

2.1 BOILER ROOM BOILER ROOM DIMENSIONS 2.3 CONNECTING UP SYSTEM 2.4 CONNECTING UP FLUE 2.5 ELECTRICAL CONNECTION

INSTALLATION INSTRUCTIONS

GIACOMINI UNDERFLOOR HEATING CONTROLS GUIDE

Three-way reversing valve

Heating Technology sinc e

51AKB / 51 AKC OWNER S MANUAL

AGA TOTAL CONTROL. Model No s: TC3 & TC5 (ROOM VENT OPTION)

INSTALLATION AND OPERATING INSTRUCTIONS KLIMA

Thermostatic mixing valves with replaceable cartridge for centralized systems

Brazed heat exchanger XB06 & Flow-compensated temperature controller IHPT (PN16)

Section - A. Radiator Valves

RA15/6T & TB Conversion Valve

THERMOSTATIC MIXING VALVES FOR CONDENSATION PREVENTION

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

PANDORA HEAT BANKS OXFORD BROOKES, HARCOURT HILL. Operation and Maintenance. THERMAL INTEGRATION LTD. Tel: Internet:

Standard. Thermostatic Radiator Valves Thermostatic valve body without presetting

Thermostatic valve bodies

Transcription:

PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING R557

SUMMARY 1. APPLICATION 1. OPERATING 2. COMPONENTS 3. OVERALL DIMENSIONS 4. APPLICATION EXAMPLE 6. POSITIONING OF THE HEAD WITH THERMOSTATIC OPTION 6. CIRCUITS BALANCING 7. ACTUATOR ASSEMBLY 8. EXAMPLE OF ELECTRICAL CONNECTION 8. PRESSURE LOSS DIAGRAMS 9. TECHNICAL SPECIFICATIONS

June 2007 0131EN ISO 9001: 2000 0006/5 IT-3995 PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING Application During recent years, planning and installation of heating systems has shown a considerable evolution, due to customer requirements seeking higher environmental comfort by limiting management and maintenance costs. One of the most popular solutions is the mixed system, where in the same property radiators are supplied at high temperature and circuits with underfloor heating are supplied with water at low temperature and used in the same system. The R557 pre-assembled manifold is particularly useful in these applications, i.e. where the system dimensions are limited and where the installation of an electronic regulator with the relevant component controls is not used. The mixing and regulating manifold R557 allows distribution of water at low temperature to the secondary circuit at a fixed point by drawing off from the primary circuit at a higher temperature, which is necessary for supply to a towel rail, radiators etc. Operating M TS S VD T P V R D The valve V and lockshield D constitute the connection points to the primary circuit at high temperature. The valve V receives water at a temperature of 70 80 C, while from the lockshield D a flow similar to that received through the valve V returns to the boiler at a temperature similar to that of the return to the underfloor heating system. The R462L thermostatic head T is fitted to the valve body limiting the range to 20 70 C and is supplied with a sensor S inserted into the upper flow manifold M of the underfloor heating system. The return water from the underfloor heating arrives to the lower manifold R where a small part flows towards the lockshield D and consequentially to the return primary circuit, while the larger quantity drawn from the pump P is mixed with the high temperature water coming from the valve V. By positioning the thermostatic head T to a prefixed flow temperature for underfloor heating, we will obtain movement of the valve V allowing the relevant amount of hot water to enter the inlet of the manifold, depending on the heat load being sufficient to maintain constant flow temperature. 1

In order to avoid an unrequired temperature increase of the primary circuit, it is recommended to fit a security thermostat TS to the R557 manifold which in case of failure will interrupt the pump supply P. In these conditions water at high temperature is pushed by the pump of the primary circuit (required for correct operation of the manifold). Arriving from valve V flows from the lockshield valve D without entering the underfloor heating system as pump P is switched off. In order to regulate the different circuits of the underfloor heating system, actuators type A thermostatic head with remote sensors or room thermostats can be fitted to the manifold. The differential valve VD installed on the manifold avoids pressure changes when the actuators close. Components The pre-assembled manifold for underfloor heating systems is supplied with: - R553S flow manifold with built-in balancing lockshield valves - R553V return manifold with built-in balancing valves - R588L adjustable brackets - R557B T with nut and tail piece - R557D T with nut and tail piece - R252 Isolating pump valve - R462L Thermostatic head temperature limiting with 20 70 C field - R554D self-sealing connection, thermometer, automatic air vent - R554A self-sealing connection with automatic air vent, differential valve - R557P tail piece In order to complete the Group, the following products have to be added according to the requirements: - R401TG/R402TG Angle or straight valve or R411TG/R412TG - R14TG or R15/TG angle or straight lockshield valve or R29TG, R31TG - R593 Plug with air vent connection of the suitable size, for valve and radiator connection - K373 Thermostat with immersion temperature sensor, with R227 flow temperature sensor housing - R179 adaptors for PE-X or Pb pipes, R179AM for multilayer pipes or R178 adaptors for copper pipes - R473/R478 actuators or R463 thermostatic heads with remote sensors - Circulating pump having 130/180 mm interaxis - R500 manifold cabinet, stove enamelled 2

June 2007 0131EN ISO 9001: 2000 0006/5 IT-3995 PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING Overall dimensions If the R557 is supplied with a circulating pump having 130 mm interaxis, the R500 stove enamelled cabinet can be used. For pumps having 180 mm interaxis (the application of which is limited to certain circumstances due to the height of the manifold), a suitable cabinet must be made up on site by the installer. X I B B K N O M E K B G G H I B L PART NUMBER G B OUTLETS I K H E M N O L X R557Y002 1 18 2 50 1 1/2 433-473 274-314 137 130-180 / 377 116,6 R557Y003 1 18 3 50 1 1/2 433-473 274-314 137 130-180 / 427 116,6 R557Y004 1 18 4 50 1 1/2 433-473 274-314 137 130-180 100 477 116,6 R557Y005 1 18 5 50 1 1/2 433-473 274-314 137 130-180 150 527 116,6 R557Y006 1 18 6 50 1 1/2 433-473 274-314 137 130-180 200 577 116,6 R557Y007 1 18 7 50 1 1/2 433-473 274-314 137 130-180 250 627 116,6 R557Y008 1 18 8 50 1 1/2 433-473 274-314 137 130-180 300 677 116,6 R557Y009 1 18 9 50 1 1/2 433-473 274-314 137 130-180 350 727 116,6 R557Y010 1 18 10 50 1 1/2 433-473 274-314 137 130-180 400 777 116,6 R557Y011 1 18 11 50 1 1/2 433-473 274-314 137 130-180 450 827 116,6 R557Y012 1 18 12 50 1 1/2 433-473 274-314 137 130-180 500 877 116,6 3

Application example The R557 manifold is supplied without thermostatic valves and lockshields, as they should be chosen in accordance with the requirements of the water flow at high temperature. The quantity of water circulating in the manifold and consequentially in the circuits of the underfloor heating is not the only consideration allowing this choice, as it must be related to the radiator outputs and to the difference in temperature between primary and secondary circuits. It is important to choose the correct size of thermostatic radiator valve body on the primary flow to ensure accurate flow rates to the system. This phenomenon happens where the temperature of the primary circuit is not constant and subjected to wide variations (i.e. wall hung boilers where we have low inertia and limited on-off operations). In certain cases this phenomenon is so evident that a high level thermostat must be used to close the pump to avoid relevant operational problems. Otherwise if the valve with thermostatic option is not of the correct size the start up time will be longer and the system will have limited performance: in these cases the water velocity to the manifold is increased by the additional flow rate from the valve with a consequent increase in pressure loss (not always allowed for by the pump of the primary circuit) and increased noise will be evident. In order to select the correct sizes of valves with thermostatic option it is necessary to study the following diagram: Qp Tm Qp Tc Qp Tr Qp Tr Qp Qc Tc Tm Tr Water flow for underfloor heating circuits (l/h) Water flow from the primary circuit at high temperature (l/h) Water flow temperature from the primary circuit at high temperature ( C) Flow temperature to the panel radiator circuits ( C) Return temperature from the panel radiator circuits ( C) 4

June 2007 0131EN ISO 9001: 2000 0006/5 IT-3995 PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING By taking into consideration a constant specific heat and density of water at high temperatures used in the R557 manifold the following can be expressed Qp x ( Tm - Tr ) = Qc x ( Tc - Tr ) from this formula the Qc flow is obtained which will select the valve dimension. Qc = Qp x (Tm - Tr) (Tc - Tr) If for example water temperature of the primary circuit which supplies the manifold is Tc=80 C and the circuit with underfloor heating is calculated with Tm=40 C and Tr=35 C (then with a difference of temperature Dt = 5 C) for a total flow of the manifold with underfloor heating of Qp=1000 l/h we will obtain the following. Qc = 1000 x With this flow value from the pressure loss diagrams of the valves with thermostatic option, can see that a 3/8 valve will have a pressure loss of ca. 400 mm water column and a 1/2 valve will have a pressure loss of ca. 290 mm water column and so it will be suitable for this operation. If in the previous example we had a water temperature of the primary circuit supplying the manifold Tc= 55 C the water flow entering under the same conditions, the secondary circuit will be Qc = 1000 x (40-35) (80-35) (40-35) (55-35) = 111 l/h = 250 l/h which in a 1/2 thermostatic valve will have a pressure loss of 1700 mm water columns extreme for many applications, while in a 1 valve the pressure loss is of 370 mm water columns, admitting value. These considerations indicate that in case of high primary circuit temperatures, the water entering the manifold inlet becomes low and requires the use of thermostatic valves and lockshields of limited sizes. Otherwise if the primary temperatures are low as i.e. in systems with condensing boilers, the inlet flow increases and valves with larger dimensions are required. 5

Positioning of the head with thermostatic option The flow temperature of the system with underfloor heating can be pre-determined by positioning the R462L thermostatic head according to the values reported in the following table. Regulation precision is very high (± 1 C ca.) and it is suggested to proceed with the calibration by making some adjustments of the head position with the system. In order to avoid tampering it is possible to lock the head by using the setting on the regulation valve, which is adjusted by key. Position * 1 2 3 4 5 6 T[ C] 20 23 34 45 56 67 70 Circuits balancing The flow manifold has built-in adjustment with mechanical memory for circuit balancing. By using R558 key it is possible to fully open the regulation valve with a screwdriver and then starting from the fully closed position, open the lockshields the number of turns obtained from the calibration diagrams. After having completed the balancing, tighten the regulating valve again on the relative lockshield valves. This operation will allow to open and close the circuits without loosing the initial calibration position. 6

June 2007 0131EN ISO 9001: 2000 0006/5 IT-3995 PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING Actuator assembly R473 If the R557 manifold supplies circuits installed in the same apartment or house, we suggest to regulate the room temperature by installing a thermostat able to directly control the pump by fitting a simple timer to limit the on and off switch. If circuits for heating different rooms are connected to the manifold, the higher comfort and saving is obtained by installing in each room (K480 thermostats) connected to R473 or R478 actuators, or to the R463 thermostatic heads with remote sensors. Our actuators are easily installed on the return manifold by removing the valve shut-off cap. R478 7

Example of electrical connection The following scheme shows a typical mixed system where standard radiators at high temperature are combined with R557 manifold for underfloor heating systems. The electrical system has to be made by allowing that the pump of the primary circuit is operating when the pump of the manifold is started and the side at high temperature is working also when the R557 group is switched off. The scheme has to be followed according to the type of actuator installed and system complexity, by using suitable electrical components. Thermostat Thermostat Thermostat R R R R K373 R473 R478 Pressure loss diagrams Manifold with R473/R478 actuators 2000 1 2 3 4 5 TA 1500 rp [mm H 2 O] 1000 900 800 700 600 500 400 300 Opening turns Kv 1 0,17 2 0,27 250 200 3 0,54 4 0,83 150 5 1,15 100 10 15 20 25 30 40 50 60 70 80 90 100 150 200 250 300 400 500 600 700 800 900 1000 TA 1,35 Q [l/h] 8

June 2007 0131EN ISO 9001: 2000 0006/5 IT-3995 PRE-ASSEMBLED MANIFOLD FOR HEATING SYSTEMS WITH THERMOSTATIC MIXING Group with R463 thermostatic heads with remote sensor in D 2 C 2000 1 2 3 4 5 TA 1500 rp [mm H 2 O] 1000 900 800 700 600 500 400 300 Opening turns Kv 1 0,17 2 0,26 250 3 0,40 200 4 0,45 150 5 0,51 100 10 15 20 25 30 40 50 60 70 80 90 100 150 200 250 300 400 500 600 700 800 900 1000 TA 0,55 Q [l/h] Technical specifications Pre-assembled manifold for radiant systems with fixed point regulation, composed by a delivery manifold with regulation micrometric lockshield valves, and by a return manifold complete with micrometric valves with thermostatic option. It is equipped with temperature limiting thermostatic head and intermediate fittings with discharge cocks. Max water temperature: 110 C. Max system pressure: 10 bar. This technical communication has an indicative value. Giacomini S.p.A. has the right to make in anytime, without previous advice, modifications to the products contained in the present communication for technical or commercial reasons. Information reported in this technical communication does not free the user from scrupulously following the existing technical instructions. A reproduction, also partial, of the text is forbidden, except for previously written authorisation from the Management. 9

JUNE 2007 TECHNICAL COMMUNICATION GIACOMINI N 0131EN IT REPLACES THE TECHNICAL NOTICE N 4-050GB GIACOMINI SPA Via per Alzo,39 28017 San Maurizio d Opaglio (NO) ITALY tel. 0322 923111 - fax 0322 96256 e-mail: info@giacomini.com internet: www.giacomini.com