BeSMART Thermostat. EN Thermostat Manual

Similar documents
PROGRAMMABLE 7-DAY THERMOSTAT

PROGRAMMABLE 7-DAY RF THERMOSTAT

Installer and User Manual. BeSMART. Thermostat WiFi Box and boiler RF receiver. Installer and User Manual ESC MODE SET PROG RESET

Vokèra OpenTherm 711 with external sensor connected

Vokèra OpenTherm 711 without external sensor connected

Installation & User s Instructions

CRX Single Zone Wireless Controller. Installation and User Guide. 1. Getting to know your CRX2 wireless controller

2017 EcoFactor, Inc.

Operating Instructions Model: PRT-TS WiFi RF. 01/13 Version 1 Ref: PRT-TSWIFI RF

Wireless Thermostat (WTS10) Keypad Operation Guide

RF Programmable Room Thermostat User Instructions

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

Easy-Stat. Wireless Programmable Room Thermostat Pt No

Cloudwarm W i- Fi Thermostat Comfort Anywhere Anytime MANUAL

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

Condensing Boiler RS100 Controller Training Program

Modulating clock thermostat

USER MANUAL ACQUAHOME 32 B BLU

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

Model: Touch-RF. 1 Wireless Series

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

ir-range 8G /03.15 Changes reserved.

2018 thesimple, Inc.

Lyric T6 & T6R Smart Thermostat

Model: RT310i. Smartphone Controlled Thermostat. Installation Manual

User Manual RBS 24. for model CE series ENERGY. Wall mounted instantaneous combi boiler room sealed chamber

50110_HM-neoStat-2014_Layout 1 31/10/ :33 Page 1 neo

User Instructions For TopTronic RS-30

Welcome to Unilux VFC Wall-mount Thermostat

User Manual for model

Roth Touchline. German quality since Quick and easy user manual 1/10

R. Room temperature controller with solar control FR 120. Operating instructions for the user (2012/02)

Aqua Balance. AquaBalance TM CONTROL MODULE QUICK START GUIDE LEGEND

MySMART Condensing Wall-Hung Boilers

Type UCG/UDG. English...1 Français...7 Español Up button. OK button. Down button

Edited by Foxit PDF Editor Copyright (c) by Foxit Software Comp. Programmable digital room thermostat. NEW software! Operating Instructions

INSTRUCTION FOR THE USER THC V E OIL BLU

Model: Available in : Sapphire Black and Glacier White. 1 Series

ProCon 16, 31, 47, 75, 77 & HT. RVA 46. Zone Controller Commissioning Data.

DOMESTIC HOT WATER Follow operational sequence

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

KIT UNITÀ AMBIENTE E INTERFACCIA A LED KIT ROOM UNIT AND LED INTERFACE RAUMGERÄT UND LED-SCHNITTSTELLE KIT APPAREIL D'AMBIANCE ET INTERFACE À LEDS

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

SMART THERMOSTAT WITH HOT WATER CONTROL

Great Britain en. Installation, user and service manual. Control panel HMI Gas 310/610 ECO PRO

12V. Model: Available in : Sapphire Black and Glacier White. 2 Series

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

ENGLISH. REMOTE CONTROL / ROOM THERMOSTAT Wireless INSTALLATION SERVICING AND USER MANUAL

Model: Available in: Sapphire Black and Glacier White. 1 Series

ThermoPlus AS2-RF & ASR-RF Installation Instructions

ProCon Boiler Controller Commissioning Quick Reference Guide

Model: 1 Series 12V. Available in: Sapphire Black and Glacier White

ProCon 16, 31, 47 & 75. RVA 63 Boiler and Circuit Controller Commissioning Data.

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override

COnDEnSInG BOIlERS TAU UNIT OIL USER parameters manual

Drayton Digistat +3RF

The easier, smarter heating system. Multi-zone heating made easy. User guide Setup and control

C-Stat 17-ZW User Instructions

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

GENUS HE GENUS HE 24 GENUS HE 30 GENUS HE 38. User Manual. Condensing wall hung system boiler

Model: PRT-TS / PRT-NTS

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

SAS908WHB-3-RF/B WIRELESS THERMOSTAT

ETN-24-SUPER-PROG (US Program - Celsius)

Model: Slimline-RF. 1 Slimline Series

Floor heating controls, radio connection 1

Room thermostat with Auto Timer, independent DHW

Wiser Air User Interface Guide. Thermostat

INTELLICOMFORT CH180WIFI TOUCHSCREEN PROGRAMMABLE THERMOSTAT WITH WIFI CONNECTION FOR REMOTE CONTROL

Roth Touchline. German quality since User manual quick and easy guide 1/10

/18 (JRK) MTD User Manual OJ Electronics A/S

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

GreenCon On/Off Room Thermostat

MCD User Manual

Refrigerated air dryers

- Brochure D 542. Introduction. Features. tekmarnet 4 Thermostat /05. 5 Data Brochure Control settings wiring instructions

User Manual THR872CUK Wireless Programmable Thermostat

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

WATER HEATER ELECTRONIC CONTROLLER USER MANUAL

Model: Touch-RS. 1 Touch-RS

prestige Control Application Supplement WARNING

- Data Brochure tekmarnet 4 Thermostat 542e

2-zone application 2X T6R SMART THERMOSTAT & 2-CHANNEL RECEIVER BOX FEATURES APPLICATION MANUAL

FAMILY PRO SIMPLY THE BEST

Operation GT7000. Time / Current Temp. TEMP UP button. Display. Fan. Switch. Set Temp. Display. Mode Switch. Backlight. TEMP DOWN button.

Smart Thermostat. Set-Up Guide

MC200. Users Instructions. HEATING DIVISION Hort Bridge Ilminster, Somerset TA19 9PS Tel: Fax:

3 Channel Multi-Purpose Programmer User Instructions

THE EVOLUTION OF CONTROL APP & CLOUD PORTAL

PRT-TS WiFi PRT-TS WiFi

INTRODUCTION Thank you for purchasing your new Comfort-Set 90 Series thermostat. Your new White-Rodgers Thermostat uses solid state microcomputer

T6 and T6R SMART THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CONTROLS WI-FI THERMOSTAT. icomfort Wi-Fi Flex Thermostat PRODUCT SPECIFICATIONS

prestige Control Application Supplement - ACVMax

prestige Control Application Supplement - Type 5 MCBA WARNING

E-COMBI EVO E-SYSTEM EVO

ERV-24. Technician Settings & Operating Manual. Protected by one or more of the following patents: US 5,547,017; 5,881,806; 6,431,268; CA 2,245,135

Watts Under Floor Multi-zone Controller User Manual

Transcription:

BeSMART Thermostat EN Thermostat Manual

1 Basic information Desired room temperature (up to 3 set) Room temperature Heating request (if ON/OFF connected Flame presence (if OT-Bus connected) Cooling mode enable + Forward scrolling of the menu in AUTO mode, advanced function activated SET-PROG = programming menu ESC = exit MODE = select the following working mode: AUTO MANUAL HOLIDAY PARTY SUMMER (if OT-Bus available) OFF Back scrolling of the menu In AUTO mode, function ONE HOUR BOOSTER activation In case of alarm (AXX on main display) press for 1 second and reset the alarm on the display If RIE on the display, press 3 secs ESC- MODE to activate the semi-automatic boiler filling -

2 Direct functions 2 1 3 Function RF pairing Press for 5 seconds the ESC-MODE button (5), the thermostat will then enter RF coupling mode and this function is needed to couple the thermostat with an RF receiver (Wi-Fi Box or boiler receiver). Also the boiler receiver or the Wi-Fi Box must be moved to the same mode to complete the coupling operation (see following page). Once completed, the two line display will disappear and the alphanumeric code of the coupling will be shown Function RESET When an alarm code is displayed (only available if OT-Bus connection available between Wi-Fi Box and the boiler and if the OT-Bus protocol is allowed to this), it is possible make a reset of the alarm pressing once the RESET button (3) Function semi-automatic filling of the system (only for boilers incorporating this function) On the thermostat display is shown rie flashing when the system needs to be filled. It is possible to activate the automatic filling by pressing the ESC-MODE button for 5 secs. At the end of the automatic filling cycle, the display will resume to a normal visualization. 4 6 5 Desired room temperature The thermostat can accept the setting of 3 different temperature level: T3 = Comfort (day temperature) in mode AUTO, PARTY and MAN T2 = Economy (night temperature) in mode AUTO and HOLIDAY T1 = frost protection in mode AUTO and OFF The 3 temperatures can be changed when active; by moving the buttons UP (4) and DOWN (6) if the thermostat is set on the mode related to this temperature level or from the PROGRAMING MENU T1-T2-T3 Working modes Pressing the ESC-MODE (4) button, it is possible to select the following working mode: AUTO = thermostat working in heating/cooling at temperatures level T3-T2-T1 according the selected hours. MANUAL = thermostat working in heating/cooling at temperatures level T3 (Comfort) only, without any restriction on hours. HOLIDAY = thermostat working in heating/cooling at temperatures level T2 (Economy) only for the number of days set, without any restriction on hours. PARTY = thermostat working in heating/cooling at temperatures level T3 (Comfort) only, up to the midnight of that day, without any restriction on hours. OFF = thermostat OFF (when ON/OFF connection) or boiler totally OFF (stand by) (when OT-Bus connection). DOMESTIC HOT WATER (DHW SUMMER) = boiler in summer mode domestic hot water only (only available when OT-Bus connection and if the protocol allow this). Function ADVANCED Only in AUTO mode, by pressing the FORWARD button (1) the ADVANCED function is enabled or disabled (if enabled the MAN icon is also shown on display). The function is used to advance to the next scheduled heating program event (ON or OFF) with related set temperature, possible up to midnight on that day. This temporary function is helpful when arriving home early or leaving home before the next scheduled (OFF) event. Function ONE HOUR BOOSTER Only in AUTO mode, by pressing the BACK button (3) the ONE HOUR BOOSTER function is enabled or disabled (if enabled the MAN icon is also shown on display). This function switches ON the heating at T3 (Comfort) for 1 hour. If current time is already in T3 (Comfort), this function adds 1 hour to the current programmed time.

3 Functions/Icons/Alarms 2 1 3 Low batteries Flame RF communication Heating Domestic hot water (DHW) Cooling enable 4 6 Batteries must be replaced. Functionality will be impaired if batteries become depleted. Signal of real flame presence on the boiler if OT- Bus connection or just heating request if ON/OFF connection. Radio frequency (RF) communication ON with the Wi-Fi Box or boiler receiver. Heating mode enabled. Domestic hot water mode enabled (only if OT- Bus connection available with the boiler). Cooling mode enabled. (inversion of the relay working mode) 5 Function pairing in RF of others devices of BeSMART system. It is possible to pair up to 8 devices (thermostats or boiler receiver) to the Wi-Fi Box. To enable the RF pairing function, press and hold for 5 secs the transparent LED button on the Wi-Fi Box or the boiler receiver, until you have simultaneous and rapid flashing (0,5 secs) of the green and red LEDs. Once pairing is complete, the LED s automatically return to their normal state. Reset of the self configuration (OT) function The thermostat is factory set to work in ON/OFF. In case of OT-Bus connection available (wired or wireless) the thermostat automatically detect the BUS communication. The device automatically move to OT-Bus working mode (boiler remote control). To reset to the original factory set configuration in ON/OFF, it is necessary to remove and replace the batteries. Alarms rie Err E82 E83 E84 A01-A10 A02-A20 A03-A30 A04-A40 A06-A60 A07-A70 A08 A09-A91 A77 A99 Main alarms and description Semi-automatic system filling function Thermostat temperature sensor damaged (non-repairable) Radio frequency communication missing OT-Bus communication missing Hardware damaged not repairable Ignition failure High limit thermostat intervention Alarm final flues thermostat and/or limit thermostat and/or air pressure switch and/or premix fan Low system pressure Alarm DHW NTC sensor Alarm NTC heating and/or NTC flow sensor and/or higher delta T between flow and return Alarm NTC return sensor and/or higher delta T between flow and return Alarm flues NTC sensor or heat exchanger need cleaning Low limit thermostat intervention Too high reset from remote location

4 Working mode MODE Heating Icon Description AUTO MANUAL HOLIDAY PARTY DHW OFF The thermostat will follow the heating program that s been set or selected via the PROGRAMMING MENU HEATING PATTERN and the selected temperatures on the PROGRAMMING MANU T1-T2-T3 (the values can also be selected individually with the UP (4) and DOWN (6) buttons when the thermostat is following the relevant set temperature). The heating/cooling request is enabled or disabled according to the current room temperatures, the desired room temperature and the programmed timing. There are 3 selectable temperature levels and the minimum selectable programming (ON/OFF) periods, are 30-minute segments. The thermostat is in manual mode and reacts according to the room temperature and desired room temperature, not according the programmed heating ON/OFF times. The heating/cooling request is activated according to the current room temperature and the set desired room temperature T3 (Comfort). The thermostat is working in manual mode according to the room temperature and desired room temperature, and not according to the programmed heating timing. The heating/cooling request is activated according to the current room temperature and the desired room temperature T2 (Economy). This working mode is active for a number of days selected on the main display page with the FORWARD (1) button, up to midnight of the last day selected. After the set days have expired, the thermostat mode of operation automatically returns to AUTO. The thermostat is working in manual mode according to the room temperature and desired room temperature, not according the programmed heating timing. The heating/cooling request is activated according the current room temperature and the desired room temperature T3 (Comfort). This working mode is active up until midnight of the day. Thereafter the thermostat mode of operation automatically returns to AUTO. The thermostat is working in domestic hot water mode only (available only with OT-Bus connection between the Wi-Fi Box and the boiler and if the OT-Bus protocol allows this). Tap icon flashes when the boiler is delivering domestic hot water. Thermostat working mode is OFF (no heating/cooling request). If there is OT-Bus connection between the Wi-Fi Box and the boiler (and if all the thermostats connected are OFF), the boiler is completely OFF mode (no heating/cooling, no domestic hot water, only boiler frost protection active).

5 Programming menu A B C or Select the desired icon Icon Description Lower menu dhw InFO Set the HOURS and DAY. Press again the SET-PROG (2) to enter on lower menu and proceed to set. Hours and day are automatically set if Wi-Fi Box connected to an internet network. From APP it is possible to synchronize the hours and the day of the thermostat with your Tablet or Smartphone time. Set the temperature of DOMESTIC HOT WATER (when OT-Bus connection available between Wi-Fi Box and the boiler). Press again the SET-PROG (2) to enter on lower menu and proceed to set. Reading SENSORS/BOILER SETTINGS (when OT-Bus connection available between Wi-Fi Box and the boiler and if the OT-Bus allow it). Press again the SET-PROG (2) to enter on lower menu and proceed to read the values available. Select with the buttons FORWARD (1) or BACK (3) the desired value (hours, minutes or days) and with the UP(4) and DOWN (6) buttons select the values. Press the SET- PROG (2) button to enter and return to the programming menu, press ESC-MODE (5) to escape from the programming menu or wait 5 seconds to auto exit. Select with UP (4) and DOWN (6) buttons the desired temperature value. Press the SET-PROG (2) button to enter and return to the programming menu, press ESC-MODE (5) to enter and esc from the programming menu or wait 5 seconds to auto exit. They are shown in sequence the followings info (if value not available - - is shown): tset = set-point flow temperature calculated by the thermostat. tflo = reading of the boiler flow sensor temperature. tret = reading of the boiler return sensor temperature. tdh = reading of the boiler DHW sensor temperature. tflu = reading of the boiler flues sensor temperature. test = reading of the boiler outdoor sensor temperature (fitted to the boiler or communicated by the web). MOdU = instantaneous percentage of modulation of boiler fan. FLOr = instantaneous domestic hot water flow rate. HOUr = hours worked in high condensation mode. PrES = central heating system pressure. tfl2 = reading of the heating flow sensor on second circuit

6 Programming menu (cont.) Icon Description Lower menu Set the desired room temperatures level T1-T2-T3.. Press again the SET- PROG (2) to enter on lower menu and proceed to set. The 3 values can be changed individually with UP (4) and DOWN (6) buttons when the respective T value is active on the thermostat Set the PROGRAMMING HEATING/COOLING PROGRAMMING TIME. Press again the SET-PROG (2) to enter on lower menu and proceed to set. With FORWARD (1) and BACK (3) buttons select the period (mon-fri, satsun, single day). Press again the SET-PROG (2) to enter on lower menu and proceed to set. Select with the buttons FORWARD (1) or BACK (3) the desired value (T1, T2 or T3) and with the UP(4) and DOWN (6) buttons select the values. Press the SET-PROG (2) button to enter and return to the programming menu, press ESC-MODE (5) to enter and esc from the programming menu or wait 5 seconds to auto exit. Select with the buttons FORWARD (1) or BACK (3) the segment of hours that need to be modified and with the ESC-MODE (4) select the desired temperature value level (T1, T2, T3). Press the UP (4) button to copy the previous setting on the following hours fascia (use the DOWN (6) button to go back). Press SET-PROG (2) to enter and esc from the programming menu or wait 30 seconds to auto exit. Set the HEATING or COOLING mode. Press again the SET-PROG (2) to enter on lower menu and proceed to set. Attention! If the OT-Bus connection establish between the Wi-Fi Box and the boiler, in case of COOLING mode, the cooling request is managed only via ON/OFF (heating is disable vs the boiler). Technical menu (available only to service personnel). Press again the SET-PROG (2) to enter on lower menu and proceed to set. Select with the UP (4) or DOWN (6) the desired value: IN = winter = heating mode SU = summer = cooling mode Press the SET-PROG (2) button to enter and return to the programming menu, press ESC-MODE (5) to enter and esc from the programming menu or wait 5 seconds to auto exit. Set the password (password for technical menu = 18) using the UP (4) and DOWN (6) buttons and press SET-PROG (2) to enter. Press SET-PROG to exit from the programming menu.

7 Technical menu and expert settings PL A B C PASSWORD Parameter / Icon Description Parameter / Icon Description 01 t0 08 HH/LL CH 10 CLI 11 InFL Set the minimum limit temperature (frost protection for ON/OFF and DHW/SUMMER mode). Set max and minimum set point in heating. Set the climatic curve for thermoregulation. Set the influence of the room sensor on thermoregulation calculation. Available only when OT-Bus connection. 13 CALI Calibration of the room sensor 14 FACt Factory values RESET (general RESET) 16 SOFt Software version of the thermostat 17 degr Set degree in Celsius or Fahrenheit 19 H On/OFF Set hysteresis On and OFF 21 ALL 22 tsp 23 LEGI 24 CLOC 26 tsft 27 SEnS Alarms history.. Boiler parameters setting (TSP). Legionella function activation. Domestic hot water clock activation. Night swift flow temperature reduction. Temperature sensor disability (for pure climatic curve activation when in OT) 28 FCLO Set clock display 24hr or 12 hr (am, pm). 29 CHOt Disable the OT CH request when OT-bus connection More info and support at: www.besmart-home.com BeSMART is a RIELLO GROUP brand Via Ing. Pilade Riello, 7 37045 Legnago - Italy