MAR2 LED SERIES Linear LED Lighting for Hazardous Locations Class I, Division 2, Groups A, B, C & D UL 844 Hazardous Locations UL 1598A Marine Outside Type UL 8750 LED Safety CSA C22.2 #250.0-08; CSA C22.2 #137-M1981 ETL Listed 55 C Ambient Temperature Tested to LM 79 & LM 80 M A R 2 L E D 103
MAR2 LED SERIES Linear LED Lighting for Hazardous Locations Each MAR2 Series fixture is individually tested for functional and dielectrical strength at the factory to assure quality and reliability. This heavy-duty fixture arrives completely assembled. Watershed design. Ultra-violet resistant plastic hinges for ease of access and relamping. Versatile mounting arrangments (360 ) Streamlined ribbed corrosionresistant, copper free extruded aluminum body for greater heat dissipation and extended driver life. Cast aluminum end caps with molded eye-bolt hubs. Extruded aluminum lens frame for greater strength. Shatter and heat resistant clear acrylic lens. Stainless steel cam action lens latches for maximum strength and durability. Convenient access to wiring chamber and class II driver Marine Duty testing exceeds NEMA 4X requirements for hose-down pressure and corrosion testing Seismic testing by Structural Dynamics Research Corporation (full scale seismic fragility qualification) Tested in frequencies of 1 to 31.6 hertz in 3-plane axis with maximum G force of 18.67 achieved 104 RIG-A-LITE
LED MAR2 LED Series Hazardous Locations Class I, Division 2 UL 844 UL 1598A Marine Outside Type CETL Wet Locations CSA Catalog Number Logic 1 MAR2 1 2 3 4 5 BASIC SERIES MAR2 LED Fixture Class I, Division 2, Groups A, B, C & D UL 844 Hazardous Locations UL 1598A Marine Outside Type UL 8750 LED CSA C22.2 #137 CSA C22.2 #213 ETL Listed 55 C Ambient Temperature 2 LAMP CURRENT/LAMP WATTAGE 10 = 80 Watt 3 LAMP TYPE L = LED 6 4 NOMINAL FIXTURE LENGTH 2 = Two Foot 4 = Four Foot 5 VOLTAGE/FREQUENCY U = 120 THRU 277 50/60HZ 6 OPTIONS 1 TW = End Mounting/Thru Wire Cable Installations Only F = Single Fuse 2 TM = Tempered Glass EB = Eye Bolt Only SC = Safety Cable with Eye Bolt SP = Surge Protector 1Consult factory for pricing. 2Fuse option not available for marine listed fixtures. Catalog logic is for explaining catalog number structure only. Not all combinations are possible; consult factory for catalog numbers not listed in charts. www.rigalite.com 105
MAR2 Series LED Features Hazardous Location Marine Rated LED Cast Aluminum End Caps UV Resistant Non-Metallic Hinges Extruded Aluminum Lens Frame 360 Mounting Flexibility 60,000 or more hours rated lamp life with 70% lumen maintenance 3/4 NPT Aluminum Conduit Hubs Water tight gasket attached to the lens for superior ingress protection Line Transient Protection: 4 KV line to line. 2 KV line to ground Constant Current Certifications Class I, Division 2, Groups A, B, C & D UL 1598A Marine Outside Type UL 844 Hazardous Locations UL 8750 LED Safety Tested to LM79 & LM80 CSA C22.2 #137 CSA C22.2 #213 ETL Listed 55 C Ambient Temperature Standard Materials Copper Free Extruded Aluminum Housing Stainless Steel Cam Action Latches Shatter and Heat Resistant Acrylic Lens Certification Guide Ambient Temperature C Class I, Division 2 Groups A, B, C & D Supply Wire Suitable Temp C Model MAR210L4U 55 T4A 105 MAR210L2U 55 T4A 105 22
LED MAR2 LED Series Hazardous Locations Class I, Division 2 UL 844 UL 1598A Marine Outside Type CETL Wet Locations CSA Options Class I, Division 2, Groups A, B, C and D UL 1598, UL1598A, UL844 & UL8750 CSA For drilling rig, marine and industrial lighting hazardous locations Corrosion resistant, low copper content aluminum LED fixture Versatile mounting arrangements, (360 ) Easy access to driver, boards and internal wiring Streamlined design gives eye appeal and ruggedness Designed to withstand strong vibration Watershed design Stainless steel cam action lens latches Standard terminal block provides ease of wiring Four Foot Fixture Description 80 Watt, LED and Driver System Universal Voltage, 48" Hub Size (inches) 3/4 Voltage Catalog Number 120-277V 50/60 HZ MAR210-L-4-U Two Foot Fixture 80 Watt, LED and Driver System Universal Voltage, 24" 3/4 120-277V 50/60 HZ MAR210-L-2-U Certification Guide Ambient Temperature C Class I, Division 2 Groups A, B, C & D Supply Wire Suitable Temp C Model MAR210L4U 55 T4A 105 MAR210L2U 55 T4A 105 106 RIG-A-LITE
LED MAR2 LED Series Hazardous Locations Class I, Division 2 UL 844 UL 1598A Marine Outside Type CETL Wet Locations CSA Coefficients of Utilization MAR210L4U % Effective Ceiling Cavity Reflectance rcc % Wall Reflectance rw Room Cavity Ratio RCR 0 1 2 3 4 5 6 7 8 9 10 80 50 10 50 30 10 50 30 10 50 30 10 20% Effective Floor Cavity Reflectance 1.18 1.18 1.18 1.09 1.09 1.09.99.99.99 1.02.97.93.94.91.88.86.83.81.88.81.75.82.76.71.74.70.67.77.68.61.71.65.59.65.60.56.68.58.51.63.56.50.58.52.48.60.51.44.56.49.43.52.46.41.54.45.38.51.43.37.47.41.36.49.40.34.46.38.33.43.37.32.44.36.30.42.35.29.39.33.28.41.32.27.39.31.26.36.30.26.38.29.24.36.29.24.33.27.23 Candlepower Distribution Deg. Parl. 22.5 45 67.5 Norm 0 2514 2514 2514 2514 2514 5 2516 2514 2508 2488 2491 15 2473 2471 2468 2452 2450 25 2363 2372 2366 2364 2364 35 2188 2205 2220 2186 2158 45 1920 1938 1909 1873 1858 55 1544 1579 1501 1482 1480 65 1017 1006 977 505 504 75 434 426 221 219 100 85 34 9 7 8 7 90 0 0 0 0 0 Photometric Data MAR210L2U % Effective Ceiling Cavity Reflectance rcc % Wall Reflectance rw Room Cavity Ratio RCR 0 1 2 3 4 5 6 7 8 9 10 80 50 10 50 30 10 50 30 10 50 30 10 20% Effective Floor Cavity Reflectance 1.19 1.19 1.19 1.11 1.11 1.11 1.02 1.02 1.02 1.10 1.06 1.02.99.96.94.92.90.88 1.01.93.87.88.83.79.81.78.75.92.82.74.77.71.66.72.68.64.84.73.64.69.62.57.65.59.55.77.65.56.62.55.49.58.52.48.71.58.50.56.48.43.53.47.42.66.53.44.51.43.38.48.42.37.62.48.40.46.39.34.44.38.33.57.44.36.42.35.30.40.34.30.54.41.33.39.32.27.37.32.27 Deg. Parl. 22.5 45 67.5 Norm 0 2578 2574 2565 2559 2561 5 2572 2570 2562 2559 2559 15 2515 2517 2515 2517 2517 25 2391 2394 2395 2410 2410 35 2193 2196 2217 2232 2208 45 1891 1903 1911 1869 1856 55 1469 1520 1457 1433 1425 65 937 939 923 473 463 75 373 386 195 197 167 85 23 10 6 5 5 90 0 0 0 0 0 MAR210L4U Total Lumens 7309 Input Power 81.1 (watts) Efficacy 90.1 (Lumens/Watt) CRI 84 CCT 5507 MAR210L2U Total Lumens 7257 Input Power 80.9 (watts) Efficacy 89.7 (Lumens/Watt) CRI 83 CCT 5118 www.rigalite.com 107
LED MAR2 LED Series Hazardous Locations Class I, Division 2 UL 844 UL 1598A Marine Outside Type CETL Wet Locations CSA Fixture Dimensions (inches) Dimensions (inches) MAR2 SERIES A B C D Boxed Weight Shipping Volume (Boxed Fixtures) 4 ft. models 52.13 7.38 6.19 1.81 36 lbs. 2.0 cu. ft. 2 ft. models 28.13 7.38 6.19 1.81 26 lbs. 1.0 cu. ft. Accessories Straight Mounting Kit Catalog Number: 53033 Shipping Weight: 5 lbs. Offset Mounting Kit Catalog Number: 53032 Shipping Weight: 5 lbs. Straight Brackets Catalog Number: 26364 Shipping Weight: 2 lbs. 2 required Offset Brackets Catalog Number: 26348 Shipping Weight: 2 lbs. 2 required 108 RIG-A-LITE
Accessories Straight Mounting Kit Catalog Number: 53033 Shipping Weight: 5 lbs. Offset Mounting Kit Catalog Number: 53032 Shipping Weight: 5 lbs. Straight Brackets Catalog Number: 26364 Shipping Weight: 2 lbs. 2 required Offset Brackets Catalog Number: 26348 Shipping Weight: 2 lbs. 2 required