Dual SDI Optical to Electrical Converter

Similar documents
Wideband Optical Couplers

CWDM-1-8 / 9-16 CWDM-1-8-M / 9-16-M CWDM-1-8-L / CWDM-9-16-L

ETH1000-MKII. User manual

CWDM-18. User manual. 18 channel CWDM mux/demux. Rev. B. Nevion Nordre Kullerød Sandefjord Norway Tel: nevion.

ETH1000-D. User manual

USER MANUAL. WDM-D15xx.xx. Single Wavelength Add/Drop Module for DWDM

MicroCoat Flow Guard Operating Manual

Four channel video link For low cost video transmission

HD IR Vari-focal Dome Network Camera. Quick Start Guide. Version 1.0.0

Illustra Essentials HD IR Vari-Focal Dome Network Camera Quick Start Guide

Operating Instructions

TECHNICAL PRODUCT DATASHEET

T3/E3 Fiber Optic Line Drivers

MicroCoat Flow Guard. MC480M Series. Operating Manual. IMPORTANT! Save this Sheet. Forward to Maintenance or Tool Crib Supervisors

LaserPlus Model LP-OA EDFA OPERATING MANUAL

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

Fiber Optics and Liquid Level Sensors Line Guide

Stratos Optical HD/SD BNC to "ST" Video Media Converter (Transmitter)

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

Iron Man Plus Workstation Monitor, Installation, Operation and Maintenance USER GUIDE TB Features and Components. Description.

PD100MF0MPx. Surface Mount Type, Opaque Resin Photodiode. PD100MF0MPx. Agency Approvals/Compliance. Features. Model Line-up.

EVC-P CONVENTIONAL PHOTOELECTRIC SMOKE DETECTOR. instruction manual. evolution EVC-P Conventional Photoelectric Smoke Detector

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS

OTEB-CO-B EDFA WITHOUT SNMP INSTRUCTION MANUAL

G4 Pulsed Fiber Laser

760nm Single mode VCSEL with Peltier Element and Thermistor in TO510

Class 1 laser beam sensor safe for your eyes

Product Specification

Description. Features Standard OC-48 pin compatibility Narrow spectral linewidth Low noise Meets GR 468 reliability specifications

Product Specification

DDT-4691 & DDR ASI / SD-SDI 8 Channel Mux Fibre Optic Link. User Manual. IRT Electronics Pty Ltd

HFX Fiber Optic Component 50 Mbps, 650 nm LED

Class 1 laser beam sensor safe for your eyes

Premium Desoldering station with Electric Pump Ref. DIS-D

Important Safety Notice

Description. Applications Sensor development Methane Gas detection External modulation. DFB-1XXX-BF-XX-CW-Fx-Hx-N REV 004 1

CM97-xxx-7x. Cooled 980nm Pump Laser Module. Product Datasheet. Features. Applications

Fiber Optical Multiplexer

9 W, 15 W and 25 W Industrial Fiber Laser Systems IFL Series


HEP Tech Co., Ltd. Company Profile

Set-Up Procedures. Before You Start

OPERATOR S MANUAL. Infinity Series Ceramic CO2 Laser: Models 15XXSB

IRT2 Dual Laser IR Thermometer - User Guide

2 Ensure that all personnel in the area are wearing the appropriate protective eyewear.

Laser Safety and Classification Full Version (CA-1110) Advanced Version (CA-1111) Basic Version (CA-1112)

2 WOW MOP COMPONENTS. Spray Button Power Button Nozzle. Pad Attach (Shadowed Area) Handle. Reservoir. Base

Q-SERIES DI WATER HEATER


Rosemount 0085 Pipe Clamp Sensor Assembly. Quick Start Guide , Rev CA June 2016

MX1A and MX1B: Laser Displacement Detection Sensors. 85% to 110% of the rated voltage MX1A: 15VA, MX1B: 25VA

F 2 MC-8FX FAMILY MB95200 SERIES SMOKE DETECTOR DEMO REFERENCE SOLUTION 8-BITMICROCONTROLLER APPLICATION NOTE

FS-200. Model. Instruction Manual. Infrared Food Thermometer. reedinstruments. www. com

SECTION 1: STARTING 1.1 UNPACKING AND INSPECTION

Infrared Thermometer

INTERNATIONAL STANDARD

Optical Time Domain Reflectometry (OTDR)

Self-Leveling Five-Beam Laser Pointer Model No Instruction Manual

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No , &

Portable Gas Detector RP110. User Guide. Explosive gas detection SEMICONDUCTOR sensor technology Intrinsically safe. Conformity EMC EN50270.

3R, 3G 5R, 5G Point Laser Levels

Table of Contents. Page Quick Set-up Instructions 1. Theory of Operation 2. Specifications 3. TM 1003W Controls and Connections 4

6R, 6G 180R, 180G. Users Manual. Point and Line Lasers. Line Laser Levels

Product Specification

This is a preview - click here to buy the full publication. IEC Quality Assessment System for Electronic Components (IECQ System)

Mobrey MCU900 Series 4 20 ma + HART Compatible Controller

Electronic Self-Leveling Horizontal Rotary Laser Level Model No Instruction Manual

LCP-6144A4EDRx. 10GBASE-SR SFP+ Optical Transceiver FEATURES. Description. Applications. RoHS compliant. Compliant to SFP+ Electrical MSA SFF-8431

Instruction Manual. Model No and Self-Leveling Cross-Line Laser Level

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet.

KM300 Carbon Monoxide Detection System Installation Manual

HDCVI PIR Camera User s Manual

Instruction Manual. Self-Leveling Combination Cross-Line Laser and Five-Beam Laser Dot Model No &

Instruction Manual. Self-Leveling Rotary Laser Level Model Nos and

G4 Pulsed Fiber Laser

High-Power Q-Switched Diode-Pumped UV Laser Q-Series, Q305

Wide Range InfraRed (IR) Thermometer with Type K input and Laser Pointer

Instruction Manual. Self-Leveling Rotary Laser Level Model No &

Cooled Butterfly 980nm Pump Laser Module

Class 1 laser beam sensor safe for your eyes

PQS performance specification

FCX-11AB5-3XX-XX 155Mbps BIDI SFP TRANSCEIVER(100Km)

Smoke Detector Demo Reference Solution

Instruction Manual. Self-Leveling Laser Level Model No

Dual Laser InfraRed (IR) Thermometer

TEST REPORT IEC , 2 nd Edition Part 1: Equipment classification and requirements

NLC 210 Air-Cooled Argon-ion Laser

Alcatel-Lucent 1850 TRANSPORT SERVICE SWITCH 320 (TSS-320) RELEASE 2.0 SAFETY GUIDE PN 8DG08136HAAA MARCH 2008 ISSUE 1

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

LASER SAFETY BARRIER

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

GP2Y1010AU0F. Compact Optical Dust Sensor. Description. Compliance. Applications. Features GP2Y1010AU0F. 1. Compliant with RoHS directive (2002/95/EC)

FPS CL Burst Mode SFF BIDI EPON ONU TRANSCEIVER(20Km)

Record of Amendments. Version Date Amendment Section/page affected

Datasheet: K-22 LO Sensor

Fratech Multipath-IP

Transcription:

Flashlink User Manual SDI-OE-2 Dual SDI Optical to Electrical Converter network-electronics.com Rev. 3

Network Electronics ASA Thorøya P.O. Box 1020 Sandefjord, Norway Phone: +47 33 48 99 99 Fax: +47 33 48 99 98 E-mail: support@network-electronics.com www.network-electronics.com Service Phone: +47 90 60 99 99 Revision history Current revision of this document is the uppermost in the table below. Revision Replaces Date Change description 3 2 2007-10-29 New front page and removed old logo. 2 1 2007-10-05 Added Materials Declaration and EFUP 1 0 2006-12-15 Changed maximum optical input power 0 A 30/08/05 First official release, including updated drawings and text. A - 01/06/04 Preliminary version. 2

Contents Revision history... 2 1 Product overview... 4 2 Specifications... 5 2.1 Optical input...5 2.2 Electrical...5 2.3 Electrical output...5 2.4 Standards...5 3 Configuration... 6 3.1 Format configuration...6 3.2 Configuration examples...7 4 Connector module... 8 4.1 Mounting the connector module...8 4.2 Terminal format support...9 5 Module status... 10 5.1 GPI Alarm Module status outputs...10 5.2 Front panel Status monitoring...11 6 Laser safety precautions... 12 General environmental requirements for flashlink equipment... 13 Certificate of Conformity... 14 Product Warranty... 15 Materials declaration and recycling information Materials declaration... 16 Environmentally-friendly use period... 17 Recycling information... 18 3

1 Product overview The flashlink SDI-OE-2 is a dual multi bit-rate optical to electrical converter module providing high performance media conversion for various signal formats from 19.4Mbps up to 540Mbps. This state of the art unit offers a high sensitivity PIN diode technology with long wavelength on single mode fiber. Unmatched signal accuracy, even in critical applications with pathological signal patterns makes the HD-OE-2 the first choice for all optical transport demands. The SDI-OE-2 can transport all SD signal formats in addition to DVB-ASI and SMPTE 310. It performs optical refreshing and signal reclocking, which is selectable on application. The optical input comes with a sophisticated PIN diode with a sensitivity typically better than 30dBm operating in the 2 nd and 3 rd optical windows. The open system platform of Network Electronics flashlink system allows easy interoperability with third party fiber optical systems. The two independent electrical outputs are equipped with a distribution amplifier where 2 outputs reduces the need for additional DA s. Figure 1: SDI-OE-2 Dual SDI O/E converter. 4

2 Specifications 2.1 Optical input Data rate optical: 19.4 540 Mbps. Sensitivity: Better than -25dBm Detector overload threshold: Min. -6dBm Optical wavelength: 2 nd and 3 rd optical window, 1200-1600nm. Transmission circuit fiber: Single Mode 9/125um, Multi Mode 9/125um compatible. Connector return loss: >40dB w/ SM fiber. Connector: SC/UPC. 2.2 Electrical Power: Control: +5V DC / 2.9W Max. Control system for access to setup and module status with BITE (Built-In Test Equipment). 2.3 Electrical output Number of outputs: 1. Connector: BNC. Impedance: 75 ohm. Return loss: >15dB @ 540MHz. Jitter (UI = Unit Interval): Max. 0.2UI. Peak to peak signal level: 0.8V ±0.1V. Signal polarity: 2 non-inverting. 2.4 Standards Supported standards for electrical and optical ports: SMPTE: SMPTE 259M, SMPTE 297, SMPTE 305M, SMPTE 310. DVB-ASI: EN50083-9. 5

3 Configuration 3.1 Format configuration The SDI-OE-2 can support a number of different broadcast formats. The correct configuration can either be set with a DIP switch or with the GYDA Control System. The layout of SDI-OE-2 is shown in the drawing below with the DIP switch to the upper left position. Figure 2: SDI-OE-2 board layout. DIP switch configuration must be set according to the table below: Switch # Label Function, DIP = ON Function, DIP = OFF Comment 1 RCL1 Reclocker 1 ON Reclocker 1 bypass Reclocker mode 2 PRI1 Input 1 selected Input 2 selected Output 1 3 ASI1 DVB-ASI Reclocker support SDI 177Mbps Reclocker support Select ASI or 177Mbps support 4 RCL2 Reclocker 2 ON Reclocker 2 bypass Reclocker mode 5 PRI2 Input 2 selected Input 1 selected Output 2 6 ASI2 DVB-ASI Reclocker support SDI 177Mbps Reclocker support 7 SWP Normal operation Change over functionality 8 OVR Override GYDA control. Config. with DIP switch GYDA control. Config. with GYDA All DIP switches are off when pointing towards the release handle. Select ASI or 177Mbps support Select configuration from GYDA All clock rates for SDI and DVB-ASI are automatically configured by the module itself. 6

3.2 Configuration examples Normal operation. No change over functionality. Input 1 is selected Normal operation. No change over functionality. Input 2 is selected Figure 3: Normal operation. Signal on input 2 not present. Change over. Priority on input 2 Change over. Priority on input 2 Figure 4: Change over operation. Priority on input 2. Los of signal on input 2. SDI-OE-2 will switch back to input 2 when signal is present. 7

4 Connector module The SDI-OE-2 has a dedicated connector module: HD-EO-2-C1. This module is mounted at the rear of the sub-rack. The module is shown in the figure below. Figure 5: Connector module for SDI-OE-2. In typical use a SDI-EO-2 / SDI-OE-2 module at each end will be used. Two channels simultaneously can be converted from optical to electrical channels The electrical input signal is connected to the INx input on the transmitting SDI-EO-2, and the electrical output is connected to corresponding the OUTx+ or OUTx- output BNC on the receiving SDI-OE-2. The fibre cable is connected to the corresponding optical port (OPT1 uses IN1/OUT1- and OUT1+ and OPT2 uses IN2/OUT2- and OUT2+). 4.1 Mounting the connector module The details of how the connector module is mounted, is found in the user manual for the sub-rack frame FR-2RU-10-2. This manual is also available from our web site: http://www.network-electronics.com/. 8

4.2 Terminal format support The different input and output ports on SDI-OE-2 can support a number of formats. The table below shows which signal formats are supported on the selected terminals. Terminal format support: Terminal Function Supported Format Mode OPT1 OPT2 OUT1+ OUT2+ OUT1- OUT2- Optical output Electrical Output Non-inverted Reclocked DA output Electrical Output Inverted Reclocked DA inverted output (SDI-OE-2 has noninverted outputs) GPI ALARM Open Collector Alarms SDI, DVB-ASI, SMPTE310, Transparent SDI, DVB-ASI, SMPTE310, Transparent* SDI, Transparent* Wired alarms Output Output Output OC Output SDI-OE-2 has a Transparent mode. In this mode all reclockers are switched off and no jitter attenuation will be performed. This mode may be used for non-standard or unsupported bit rates over shorter distances and up to 1 Gbps. 9

5 Module status The status of the module can be monitored in three ways. 1. GYDA System Controller (optional). 2. GPI at the rear of the sub-rack. 3. LED s at the front of the sub-rack. Of these three, the GPI and the LED s are mounted on the module itself, whereas the GYDA System Controller is a separate module giving detailed information on the card status. The functions of the GPI and the LED s are described in sections 5.1 and 5.2. The GYDA controller is described in a separate user manual. 5.1 GPI Alarm Module status outputs These outputs can be used for wiring up alarms for third party control systems. The GPI outputs are open collector outputs, sinking to ground when an alarm is triggered. The GPI connector is shown in figure below. SDI-OE-2 module GPI pinning: Signal Name Pin # Mode Status General error status for the module Pin 1 Open Collector LOS1 Loss of Signal on selected input Pin 2 Open Collector LOS2 Loss of Signal on selected input Pin 3 Open Collector Not in use Pin 4 Open Collector Ground 0 volt pin Pin 8 0V. Figure 6: GPI output. Electrical Maximums for GPI outputs Max current: 100mA Max voltage: 30V 10

5.2 Front panel Status monitoring The status of the module can be easily monitored visually by the LED s at the front of the module. The LED s are visible through the front panel as shown in the figure below. Figure 7: Front panel indicators for the SDI-OE-2. The SDI-OE-2 has 4 LED s each showing a status corresponding to the GPI pinning. Diode \ State Red LED Green LED Orange LED No light Status Module is faulty, or module is initialising. Module is OK Module power is OK Module has no power LOS/LOCK1 LOS/LOCK2 Loss of optical modulated signal. Loss of optical modulated signal. Signal is present and reclocker is locked Signal is present and reclocker is locked Signal is present, but reclocker is out of lock Signal is present, but reclocker is out of lock 11

6 Laser safety precautions Guidelines to limit hazards from laser exposure. All the available EO units in the flashlink range include a laser. Therefore this note on laser safety should be read thoroughly. The lasers emit light at 1310 nm or 1550 nm. This means that the human eye cannot see the beam, and the blink reflex cannot protect the eye. (The human eye can see light between 400 nm to 700 nm). A laser beam can be harmful to the human eye (depending on laser power and exposure time), therefore: Note! BE CAREFUL WHEN CONNECTING / DISCONNECTING FIBER PIGTAILS (ENDS). NEVER LOOK DIRECTLY INTO THE PIGTAIL OF THE LASER/FIBER. NEVER USE MICROSCOPES, MAGNIFYING GLASSES OR EYE LOUPES TO LOOK INTO A FIBER END. USE LASER SAFETY GOGGLES BLOCKING LIGHT AT 1310 nm AND AT 1550 nm. Instruments exist to verify light output power: Power meters, IR-cards etc. Flashlink features: All the laser module cards in the flashlink product range, are Class 1 laser products according to IEC 825-1 1993, and class I according to 21 CFR 1040.10 when used in normal operation. More details can be found in the user manual for the FR-2RU-10-2 frame. Maximum output power 1 : 5 mw. Operating wavelengths: > 1270 nm. < 5mW >1270nm 1 Max power is for safety analysis only and does not represent device performance. 12

General environmental requirements for flashlink equipment 1. The equipment will meet the guaranteed performance specification under the following environmental conditions: - Operating room temperature range: 0 C to 40 C - Operating relative humidity range: < 90% (non-condensing) 2. The equipment will operate without damage under the following environmental conditions: - Temperature range: -10 C to 55 C - Relative humidity range: < 95% (non-condensing) 3. Electromagnetic compatibility conditions: - Emissions: EN 55103-1 (Directive 89/336/EEC) - Immunity: EN 55103-2 (Directive 89/336/EEC) 13

Certificate of Conformity Network Electronics ASA N-3204 Sandefjord Norway Company Registration Number: NO 976 584 201 MVA Declares under sole responsibility that the product: Product Name: Product Description: SDI-OE-2 Dual SDI Optical to Electrical Converter To which this declaration relates are of Norwegian origin and are in conformity with the following standards: EN 55103-1: 1996 EN 55103-2: 1996 Generic Emissions Standard Generic Immunity Standard 14

Product Warranty The warranty terms and conditions for the product(s) covered by this manual follow the General Sales Conditions by Network Electronics ASA. These conditions are available on the company web site of Network Electronics ASA: www.network-electronics.com 15

Materials declaration and recycling information Materials declaration For product sold into China after 1st March 2007, we comply with the Administrative Measure on the Control of Pollution by Electronic Information Products. In the first stage of this legislation, content of six hazardous materials has to be declared. The table below shows the required information. Toxic or hazardous substances and elements 組成名稱 Part Name 鉛 Lead (Pb) 汞 Mercury (Hg) 镉 Cadmium (Cd) 六价铬 Hexavalent Chromium (Cr(VI)) 多溴联苯 Polybrominated biphenyls (PBB) 多溴二苯醚 Polybrominated diphenyl ethers (PBDE) SDI-OE-2 X O O O O O O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ/T11363-2006. X: Indicates that this toxic or hazardous substance contained in at least one of the homogeneous materials used for this part is above the limit requirement in SJ/T11363-2006. 16

Environmentally-friendly use period The manual must include a statement of the environmentally friendly use period. This is defined as the period of normal use before any hazardous material is released to the environment. The guidance on how the EFUP is to be calculated is not finalised at the time of writing. See http://www.aeanet.org/governmentaffairs/qfleopaazxamxqgjsfbeidsdpntpt.pdf for an unofficial translation of the draft guidance. For our own products, Network Electronics has chosen to use the 50 year figure recommended in this draft regulation. Network Electronics suggests the following statement on An Environmentally Friendly Use Period (EFUP) setting out normal use: EFUP is the time the product can be used in normal service life without leaking the hazardous materials. We expect the normal use environment to be in an equipment room at controlled temperature range (0ºC - 40ºC) with moderate humidity (< 90%, non-condensing) and clean air, not subject to vibration or shock. Further, a statement on any hazardous material content, for instance, for a product that uses some tin/lead solders: Where a product contains potentially hazardous materials, this is indicated on the product by the appropriate symbol containing the EFUP. The hazardous material content is limited to lead (Pb) in some solders. This is extremely stable in normal use and the EFUP is taken as 50 years, by comparison with the EFUP given for Digital Exchange/Switching Platform in equipment in Appendix A of General Rule of Environment-Friendly Use Period of Electronic Information Products. This is indicated by the product marking: 50 It is assumed that while the product is in normal use, any batteries associated with real-time clocks or battery-backed RAM will be replaced at the regular intervals. The EFUP relates only to the environmental impact of the product in normal use, it does not imply that the product will continue to be supported for 50 years. 17

Recycling information Network Electronics provides assistance to customers and recyclers through our web site http://www.network-electronics.com. Please contact Network Electronics Customer Support for assistance with recycling if this site does not show the information you require. Where it is not possible to return the product to Network Electronics or its agents for recycling, the following general information may be of assistance: Before attempting disassembly, ensure the product is completely disconnected from power and signal connections. All major parts are marked or labelled to show their material content. Depending on the date of manufacture, this product may contain lead in solder. Some circuit boards may contain battery-backed memory devices. 18