Replacement Parts List No. 70005300 New /207 Daikin Self-Contained Unit Ventilator UAEQ 036, 044, 054 Design H (8) To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com
Contents Parts List Revision History... 3 Nomenclature Serial Number... 4 Model Number... 4 Electrical Legend... 5 Discharge Air (Condenser) Fan Deck, Wheel, Motor, Bearing, Drain Pans... 6 Outdoor Air- Damper, Crank Arms, Linkage, Shafts, Gaskets Outdoor Air: 00%... 7 Outdoor Air: 20% Maximum... 8 Refrigeration Circuit...9-0 ECM Motor... Electric Heat...2 Control Box Electromechanical... 3 MicroTech II...4 Actuators, Thermostats, Time Clock & Sensors...5 Field Installed Accessories... 6-8 Critical Parts List...CPL UV; UAEQ 036-054 Design H(8) New /7 RPL 700053 / Page 2
Parts List Revision History Revision Date NEW /7 New Daikin Applied, 3600 Industrial Park Blvd., P.O. Box 55, Minneapolis, MN 55440 (763) 553-5330 UV; UAEQ 036-054 Design H(8) New /7 RPL 700053 / Page 3
Plant Identification Abbreviation SLP = San Luis Potosi STN = Staunton U= Unit Code Category Nomenclature Model Number UAEQ 8 054 K G 3 Z B AL 22 G W M AY 0-02 03 04 05 06 07 08 09 0 2 3 4 5 Code Item Code Option Product Category 0 U Unit Ventilator Code Designation & Model Type 02 2-4 AEQ UV, SC- Air Source Heat Pump, Ultra Quiet Design Series 03 5 8 Design H Nominal Capacity 04 6-8 Voltage 05 9 036 36,000 Btuh w/ ECM 3-Speed 054 54,000 Btuh w/ ECM 3-Speed 044 44,000 Btuh w/ ECM 3-Speed C 208/60/ D 230/60/3 G 230/60/ H 208/60/3 K 460/60/3 Cooling Options 06 0 G Direct Expansion H Direct Expansion w/ Refr Relief Valve Heating Options 07-2 Hand Orientation 08 3 Z Not Available Controls TC= Time Clock CO 2 = Return Air CO 2 Sensor 09 4-5 2 3 Element Low Capacity Electric Ht 00 None 3 6 Element Low Capacity Electric Ht B Basic E Expanded L Leading M Electromechanical ## MicroTech II Controls (see control code table below) Control Features Feature Selections Non-Communicating Stand-Alone Open Protocol BACnet Scheduling Time clock DCV CO2 Sensor Economizer Control Discharge 0 6-7 AL 6-5/8" Top Bar Grille Control Code Basic B B4 B7 B9 BC BF Expanded E E4 E7 E9 EC EF Leading-Edge L L4 L7 L9 LC LF 44 Electromechanical w/2-position OA Damper for Remote Thermostat 45 Electromechanical w/2-pos. OA Damper w/ Unit Mtd. ACO Thermostat 46 Electromechanical w/2-pos. OA Damper w/ Unit Mtd. MCO Thermostat RA/OA 8-9 22 RA Bottom Front/OA Rear 24 No OA or RA Dampers (Recirculation) Power Connection 2 20 G Box With Switch Color 3 2 I Antique Ivory G Soft Gray W Off White C Cupola White B Putty Beige SKU Type 4 22 B Standard Delivery Product Style 5 23 st Style Change Serial Number SLP U 7 05 048 Serial Number (build sequence) Week of Manufacture Year of Manufacture 7= 207 8= 208 etc. UV; UAEQ 036-054 Design H(8) New /7 RPL 700053 / Page 4
Electrical Legend Sch. Sym. Location A Actuator- OA/RA OA Damper C Contactor- Compressor Control Box CEH Contactor- Electric Heat E.H. Control Box CH Heater- Crankcase Compressor Section DF Dead Front Switch Electric Heat Section FA/FB Fuse- Compressor Damper Motor FA/FC Fuse- Compressor Damper Motor F2A/F3C Fuse- Electric Heat E.H. Control Box FA/FB Fuse- Control Main Control Box FC/FD Fuses- Electric Heat 460V E.H. Control Box HP Switch- Pressure Compressor Section HTR-6 Electric Heaters Electric Heat Section HTR0 Heater Drain Pan Outdoor Coil Section M Motor- Room Fan Fan Motor M Motor- Compressor (2- Stage) Compressor Section M2 Motor- Outdoor Air Outdoor Coil Section OH Overheat Stat Electric Heat Section OH-M Manual Reset Overheat Stat Electric Heat Section R,2,3 Relay- Electric Heat Backup E.H. Control Box R4 Relay- Fan (H=Hi, M=Med, L= Low) Main Control Box R0,,2 Relay- Electric Heat E.H. Control Box R28 Relay OA Motor Outdoor Coil Section R2S Relay High (2- Stage Comp) Indoor Coil Section R32 Relay- Drain Pan Heater Outdoor Coil Section R38 Relay-Defrost/EH Coil Electric Heat Section RV Reversing Valve Compressor Section RH Relay Hi Fan Indoor Coil Section S Sensor- Room Air Indoor Coil Section S2 Sensor- Discharge Air Indoor Coil Section S3 Sensor- Outdoor Air Indoor Coil Section S4 Sensor- Indoor DX Coil Temp. Indoor Coil Section S5 Sensor- Outdoor DX Coil Temp. Outdoor Coil Section S6 Sensor- Indoor Humidity Left End Compartment S7 Sensor- CO2 Indoor Coil Section S8 Sensor- Outdoor Humidity Damper Motor S9 Sensor- Water Out Damper Motor SW Disconnect Switch Main CB or EH Control Box SW2 Switch- On/Off Fan Speed Main Control Box SW3 Tenant Override Switch Top Right of Unit SW5 Switch- Emergency Heat Compressor Section T2 TSTAT EH Relay Electric Heat Section T4 Freezestat- DX Coil Left End Compartment T5 Thermostat- Defrost Left End Compartment T6 Thermostat- Low Limit Hyd. Coil Left End Compartment T8 Thermostat- Cooling Lockout Left End Compartment TB-3 Terminal Boards Controller TC Time Clock Top Right of Unit TDR Anti- Short Timer Main Control Box TDR2 Low Voltage Protector E.H. Control Box X Transformer- Motor Speed Main Control Box X2 Transformer- Class 2 Main Control Box X3 Transformer- 75VA Main Control Box X4 Transformer- 460V Below Motor X5 Transformer- 460V EH E.H. Control Box UV; UAEQ 036-054 Design H(8) New /7 RPL 700053 / Page 5
Discharge Air (Condenser) Fan Deck, Wheel, Motor, Bearing, Drain Pans Components Motor and Bearing Detail Back of Bearing Assy Cabinet/ Chassis components 26 2 3 4 Ref. No. Part Number Indoor Fan Motor, /4 HP 2 06326703 2 Fan Housing Assy 0620903 4 3 Wheel, Blower, Plastic 0568740 4 4 Fan Shaft, 79.5" LG GC997 26 Sleeve Bearing Assy 06959460 N/S Screen Assy, Oxford Brown 05689789 4 N/S Coupling, Motor to Shaft GC502C N/S Motor Mount 0645350 N/S External Retaining Ring 0575220 N/S Grommet 035928000 3 N/S Grommet 03592800 3 N/S Gasket 0682990 N/S Discharge Grille 0695935 N/S Condenser Drain Pan Assy 6686559 N/S Top Access Panel- Charcoal Bronze, 2" 069669 N/S Cabinet/ Chassis components N/S = Not shown on diagram. Please contact Daikin Applied with unit model and serial number for part numbers on Sheet Metal components. 2 Motors are 5/60/ regardless of unit voltage. It is important that the correct X transformer be installed. Qty. UV; UAEQ 036-054 Design H(8) New /7 RPL 700053 / Page 6
Outdoor Air Dampers, Crank Arms, Linkage, Shaft, Gaskets 09 08 30 04 03 06 Ref. No. N/S= Not shown on diagram. Part Number Unit Size 036 044, 054 03 Linkage- RA to OA 0696050 2 2 04 Linkage Assy- OA Damper, RH 05632005 06 Linkage Assy- RA Damper, RH 05632004 Linkage Assy- RA Damper, LH 05632006 08 Outdoor Air Damper 90733 2 2 09 Room Air Damper 069695 2 2 30 Spring, Damper 05708660 2 2 N/S OA Shaft, 3.25" Long 056280 3 3 N/S OA Shaft Assy 06452802 N/S Bearing, Sleeve 4ACN49 4 4 N/S Damper Gasket, Vinyl BJ027000 8. 8. UV; UAEQ 036-054 Design H(8) New /7 RPL 700053 / Page 7
Outdoor Air- 20% Maximum Dampers, Crank Arms, Linkage, Shaft, Gaskets 3 2 7 6 4 Linkage Position Ref. No. N/S= Not shown on diagram. Part Number Unit Size 036 044, 054 Damper, Motor 06502820 2 Spring, Damper 06308950 3 Bracket, Actuator Motor 668800 N/S Outdoor Air Damper 907300 2 N/S Outdoor Air Damper 90733 2 N/S Bearing, Sleeve 4ACN49 2 4 4 Damper Link 6688002 6 Crank Arm Min Air 6688003 7 Crank Arm 6688004 N/S Damper, Gasket- Mohair BY00000 2 ft. 4 ft. UV; UAEQ 036-054 Design H(8) New /7 RPL 700053 / Page 8
Refrigeration Circuit Compressor, Motors, Coils, Drain Pans, Strainer, Valves Diagrams 24 2 Outdoor Coil 2 CoreMax Valve Assy Indoor Coil 64 52 6 62 00 Compressor Mounting Detail Coremax Valve Assembly Detail 5A 5B 5C 06 UV; UAEQ 036-054 Design H(8) New /7 RPL 700053 / Page 9
Ref. No. Refrigeration Circuit Compressor, Motors, Coils, Drain Pans, Strainer, Valves Components Unit Voltage Qty. 036 044 054 Evaporator Coil Assembly w/blockoff 057079942 0627960 0627960 OX Coil only 06279590 06279590 06279590 DX Coil only 0707633 0707643 0707643 2 Strainer YL288 YL288 YL288 2 24 Expansion Valve N/A 06500608 06500608 Expansion Valve, Non-Adj. 0648928 0648928 N/A 6 Reversing Valve 900424 900424 900424 62 Solenoid, Reversing Valve 900439 900439 900439 00 Compressor- See next page 06 Grommet, Compressor Mounting 4RHD486 4RHD486 4RHD486 4 5A Seat, Fitting 6688880 6688880 6688880 2 5B Core, Valve 6688870 6688870 6688870 2 5C Cap, Valve 6688950 6688950 6688950 2 N/S Fusible Plug Assy 0728940 0728940 0728940 Plug only, 283 F 0605740 0605740 0605740 N/S Valve, Pressure Relief 66874 66874 66874 N/S High Pressure Switch, 600 PSI, NC 907269 907269 907269 High Pressure Switch, 600 PSI, NO 90727 90727 90727 Compressors Ref. No. 00 Unit Size Unit Voltage 208/230/60/ 208/230/60/3 460/60/3 Qty. Compressor, 2-Stage 036 905776 905778 905777 Compressor, 2-Stage 044 905779 90578 905780 Compressor, 2-Stage 054 905785 905787 905786 Drain Pans Ref. No. N/S Unit Voltage 036 044, 054 Qty. Drain Pan GCF506 GCF507 Drain Pan, SSTL 06345903 06345904 UV; UAEQ 036-054 Design H(8) New /7 RPL 700053 / Page 0
ECM Motor ECM Motor Nameplate 350 400 340 ECM Motor Modular Mount Detail Ref. No. Part Part Number 340 Bracket, ECM Outdoor Motor Module 0645206 350 Bracket, Support ECM Motor Module, 240V 0645207 Bracket, Support ECM Motor Module, 460V 0645208 400 ECM Motor & Program, 3/4 HP & /3 HP See ECM motor nameplate. The PN for the ECM motor is found on the label. You may also contact Daikin with the Unit Model & Serial Number to get the ECM Motor part number. Qty. UV; UAEQ 036-054 Design H(8) New /7 RPL 700053 / Page
Electric Heat Heater Assembly Heater Element # 5 Heater Element # 4 Heater Element # 3 Heater Element # 2 Heater Element # Heater Element # 6 Unit Size Electric Heat Unit Voltage 208/60/ 230/60/3 460/60/3 Heater Element (HTR -6) 036 06343603 06343607 063436 3/6 Heater Element (HTR -6) 044, 054 06343604 06343608 0634362 3/6 Switch, Toggle ALL 4EAL2427 4EAL2427 4EAL2427 Limit Switch, Auto (OH) ALL 064752 064752 064752 Limit Switch, Manual (OHM) ALL 0647525 0647525 0647525 Contactor, 3P, 60A ALL 0682320 0682320 0682320 Relay, 30A ALL 0650002 0650002 0650002 Varies Transformer, X5, 40V ALL 906208 906208 906208 Qty. UV; UAEQ 036-054 Design H(8) New /7 RPL 700053 / Page 2
Control Box Electromechanical 520 52 522 523 FC/FD 57 55 FA/FB 526 55 4 524 525 Ref. No. Part Number 4 Limit Switch, Low Temp Stat 4ELN702 N/S TStat, Defrost Limit Timer 4ELN8872 520 Switch, Rotary, 3P/4 Pos. 057542902 N/S Knob for S2 8020803 52 Transformer, Auto 9029533 522 Transformer, Ctrl, 75A, 208/230/ 906207 Transformer, Ctrl, 75A, 460/60/3 906207 N/S Transformer Assy, 500V 06325490 523 Relay, DPDT 06679300 3 524 Relay, SPDT 0609403 4 525 Contactor, 3P, 30A 9040340 526 Timer, Anti-Short Cycle 05754270 55 Capacitor, 35 MFD, 440V (208/230V) 9020050 N/S= Not Shown. X4 is mounted on the back of the control box. Qty. UV; UAEQ 036-054 Design H(8) New /7 RPL 700053 / Page 3
Control Box MicroTech II 542 540 603 X3 X C 604 620 533 Ref. No. N/S= Not Shown. X4 is mounted on the back of the control box. Part Number N/S Capacitor, 45MFD 440V 9020052 N/S Bracket, Capacitor 85000570 N/S Relay, 30A 0650002 2 533 Contactor, 2P, 30A 9040339 Contactor, 3P, 30A 9040340 Contactor, 3P, 40A 904034 540 Transformer, Auto 9029533 542 Transformer, Ctrl, 75V 906207 N/S Transformer, 750V, 460V 9093028 603 Controller, MicroTech II 06380002 604 Expansion Board, MicroTech II 060290 N/S InterfaceControl Board, LUI 063720 N/S Stand Off- Control Board 8020285 0 620 Terminal Block, 2 Pos. 0645040 2 Terminal Board 802007090 N/S Switch, Rocker, SPDT Momentary 4EAL726 Qty. UV; UAEQ 036-054 Design H(8) New /7 RPL 700053 / Page 4
Control Box Actuators, Thermostats, Time Clock & Sensors Sch. Sym. Part Number Qty. Actuators A/A2 Actuator, OA & R.A, MicroTech II 0637930 A Actuator, OA & R.A, DDC ctls 06379302 A Actuator, Non-spring Return, DDC ctls 06379402 Thermostats & Time Clock Unit Mounted ACO Stat 4ELN7447 Unit Mounted ACO Stat- 2 Stage 07339800 Toggle Switch 4EAL2427 Terminal Block 4ECA7842 Knob for Stat ZAG25258A T2 TStat, Low Temp 4ELN702 T4 TStat, Low Limit- DX Coil 4ELN7604 T6 TStat, Low Limit- Hyd. Coil 4ELN7604 T8 Thermostat, Night Setback 4ELN779 Time Clock, 24V 064560 These actuators look alike, but they are not and they DO NOT interchange. Sch. Sym. Room Sensors Sensor Only Part Number Assembly S Room Air Sensor 9040530 07303003 S2 Discharge Air Sensor 9040530 N/A S3 Outdoor Air Sensor 9040530 N/A S4 Indoor DX Coil Temperature Sensor 904053 073030 S5 Outdoor DX Coil Temperature Sensor 904053 0730302 2 S6 Indoor Humidity Sensor 064570 07304702 S7 CO2 Sensor 90672 N/A S8 Outdoor Humidity Sensor 064570 0730470 S9 Water Out Sensor 904053 0730302 Sweep Coil Sensors S5 Water In Sensor 904053 0730302 2 S9 Water Out Sensor 904053 0730302 N/A= Not Applicable. Qty. UV; UAEQ 036-054 Design H(8) New /7 RPL 700053 / Page 5
Field Installed Accessories Filters Qty. Unit Size 036 044/054 Filter, Permanent 25/Box 0563760 0563740 Filter, Renewable 2/Box 0563720 0563700 Filter, Throwaway 2 Pack 0563802 0563782 Renewable Filter Air Media for TA Two 85" Foot Rolls 0563820 0563820 Sensors & Guards- MicroTech II Part Number Standard Room Sensor with Override 0480 Deluxe Room Sensor with Override, 55-85 F Setpoint Adjust 04802 Expanded Microtech II Wall Sensor, +/- 3 F Setpoint Adjust 04803 Metal Sensor Guard for Thermostats 0566930 Thermostats & Tstat Guards Part Number Non-Programmable T'stat, 2-Heat/2-Cool, AC/DC 66837540 7-Day Programmable T'stat, 2-Heat/2-Cool, ACO 906774 T'stat Guard w/ring Base, Lock & Key 05570 Communications Modules- MicroTech II Kit Part Number N2 Communication Card Kit 0729325 BACnet Communication Card Kit 0729326 LonMark Communication Card Kit 0729327 * Kit includes MTII Comm Module, IM733 and mounting spacers part number 04866707 (Qty=4). Wall Sleeves Unit Size 036 044/054 6 5/8" Cabinet Room Projection 0730220 073023 9 5/8" Cabinet Room Projection 07302202 0730232 2 7/8" Cabinet Room Projection 07302203 0730233 28" Cabinet Room Projection 07302204 0730234 Disconnect Switch GEAA2407 GEAA24072 UV; UAEQ 036-054 Design H(8) New /7 RPL 700053 / Page 6
Field Installed Accessories Ventimatic Shutter Part Number Shutter, 0 X 24", 500CFM 077428 Shutter, 0.5 X 36", 750CFM 077429 Louver for Ventimatic Shutter No Grille/No Flange- ½ Mesh Bird Screen on Room Side Autumn Brown Dark Bronze Clear Anodized Unfinished Vertical Blade Louver 0 X 24" 669483633 669483634 669483635 669483636 Interior Steel Wall Grille- Ventimatic Shutter Antique Ivory Putty Beige Off White Soft Gray Cupola White Grille, 500 CFM 2 3/8 X 27" 05658290 05658292 05658293 05658294 N/A Grille, 750 CFM 2 3/8 X 39" 05658390 05658392 05658393 05658394 N/A Grille, 000 CFM 2 3/8 X 5" 05658490 05658492 05658493 05658494 N/A Grille, 250 CFM 2 3/8 X 63" 05658590 05658592 05658593 05658594 N/A Grille, 500 CFM 2 3/8 X 75" 05658690 05658692 05658693 05658694 N/A N/A= Not Available. Louver Heavy Gauge Aluminum w/vertical blades, ½ mesh bird screen on room side; bottom lip drains moisture Louver- Vertical Blades, 28" H X 96" L Unit Size Autumn Brown Dark Bronze Clear Anodized Unfinished Louver w/o Grille No Flange 036 669484002 669484008 66948404 669484020 Louver w/o Grille with Flange 036 669484005 6694840 66948407 669484023 Louver with Grille No Flange 036 66948402 66948408 6694844 66948420 Louver with Grille with Flange 036 66948405 669484 6694847 66948423 Louver- Vertical Blades, 28" H X 08" L Louver w/o Grille No Flange 044, 054 669484003 669484009 66948405 66948402 Louver w/o Grille with Flange 044, 054 669484006 66948402 66948408 669484024 Louver with Grille No Flange 044, 054 66948403 66948409 6694845 6694842 Louver with Grille with Flange 044, 054 66948406 6694842 6694848 66948424 Louver- Horizontal Blades, 0" H X 24" L Louver No Grille No Flange 036, 044, 054 669483733 669483734 669483735 669483736 UV; UAEQ 036-054 Design H(8) New /7 RPL 700053 / Page 7
Field Installed Accessories " End Panels Antique Ivory Putty Beige Off White Soft Gray Cupola White 6-5/8" Deep, Solid, Acoustic 06046890 06046892 06046893 06046894 06046884 9-5/8" Deep, Solid, Acoustic 05636790 05636792 05636793 05636794 05636784 2-7/8" Deep, Solid, Acoustic 06047090 06047092 06047093 06047094 06047084 28" Deep, Solid, Acoustic 05636590 05636592 05636593 05636594 05636584 N/A= Not Available. N/A= Not Available. 6" End Panels Antique Ivory Putty Beige Off White Soft Gray Cupola White 6-5/8" Deep, Solid, Acoustic 05636090 05636092 05636093 05636094 N/A 9-5/8" Deep, Solid, Acoustic 05636690 05636992 05636693 05636694 N/A 2-7/8" Deep, Solid, Acoustic 0563690 0563692 0563693 0563694 N/A 28" Deep, Solid, Acoustic 05636990 05636692 05636993 05636994 N/A Panels and Grille Assembly Unit Size 036 044/054 2" Top Access Door Panel 069669 069669 Grille Assy 0695933 0695935 Front Panel Antique Ivory 0679830 0679840 Front Panel Cupola White 067983 067984 Front Panel Putty Beige 0679832 0679842 Front Panel Off White 0679833 0679843 Front Panel Soft Gray 0679834 0679844 Touch Up Paint Kit Part Number Antique Ivory 0674723 Off White GXA60208 Putty Beige GXA60203 Soft Gray GXA60204 Kit, Complete Paint Sample Sets (5 of each color) 9084302 Castors for Indoor Section Kit Part Number Castors for Indoor Section, -Pair 0562900 UV; UAEQ 036-054 Design H(8) New /7 RPL 700053 / Page 8
Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! Daikin Unit Ventilator, Self-Contained UAEQ 036-054 Design H (8) Critical Components Unit Size Voltage Part Number Control Main Control Board, MicroTech II ALL N/A 06380002 Compressor Compressor 036 208-230/60/ 905776 Compressor 036 208-230/60/3 905778 Compressor 036 460/60/3 905777 Compressor 044 208-230/60/ 905779 Compressor 044 208-230/60/3 90578 Compressor 044 460/60/3 905780 Compressor 054 208-230/60/ 905785 Compressor 054 208-230/60/3 905787 Compressor 054 460/60/3 905786 ECM Motor ECM Motor & Program ALL ALL See motor nameplate Fan Motor Motor, Indoor /4 HP ALL 5/60/ 06326703 Fan Housing & Wheel Fan Housing Assy ALL N/A 0620903 Wheel- Blower ALL N/A 0568740 Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To www.daikinapplied.com or Call -800-37PARTS 700053 New /207 CPL Page of