Commercial Air Conditioners 2017/2018 INVERTER. DC Inverter. Aqua Mini Chillers & Fan Coil Units

Similar documents
Evaporadoras Hidrónicas

DC Inverter Chillers & DC Fan Coil Units

COMMERCIAL AIR CONDITIONERS. R410A All DC Inverter VRF V5 X Series 50/60Hz

Fan Coil Unit 50Hz 2012

VRF 50Hz. Commercial Air Conditioners V1510. V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF. Commercial Air Conditioner Division Midea Group

Commercial Air Conditioners 2017/2018. VRF 50/60Hz. V5 X Series

Commercial Air Conditioners VRF 50Hz V4+K/V4+S/V4+R/V4+W/V4+I/Mini VRF

R410A VRF Indoor Unit 50Hz AC Series

Commercial Air Conditioners Rooftop Package. R410A 50Hz

DC Inverter Smart VRF Products(R410A)

ClimaMaster Series. Rooftop Package Unit 50Hz 1311-R1211. D e a l e r i n f o r m a t i o n

Air Cooled Scroll Chiller

Midea VRF (V4+) V4+S (Heat Pump) V4+i (Individual) (Heat Pump) V4+R (Heat Recovery) MVRF 05/15

Commercial Air Conditioners. VRF 60Hz V4+S/V4+R/V4+W/Mini VRF

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

Product Line Introduction. Karl Zhang Technical support engineer

Commercial Air Conditioners Split Commercial A/C. R410A 50Hz

Aqua Mini Full DC Inverter Unitary Chiller 50Hz. Content

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

DESIGN ITALIANO

Residential and Light Commercial Ductless Systems Catalog

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

VANJSKE JEDINICE. Variable Refrigerant Flow Systems. *Preliminary data

turn to the experts R 410A DC INVERTER LIGHT COMMERCIAL SERIES

VARIABLE REFRIGERANT FLOW SYSTEMS

V4 Plus Heat Recovery VRF. Linda Lin Pre-sales Engineer

Split Commercial A/C. Commercial Air Conditioners S1610. R410A 50Hz. Commercial Air Conditioner Division Midea Group

Air-cooled modular Chiller. Nick Technical Engineer

Ultimate VRF System R410A, 50Hz

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

COMMERCIAL AIR CONDITIONERS. Aqua Mini Chiller 50/60Hz

LG VRF Systems. Air Conditioning Technologies

DES IGN I T ALI A N O

Light commercial range. Passion at work

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

MINI CHILLER INVERTER H4 Service manual MUENR-H4 (5, 7, 10, 12, 14, 16 kw)

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

Product Catalog. DCHC Horizontal Concealed Chilled Water Fan Coil with DCBL Motor Airflow: 180~2380 m 3 /h

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

TVR 5G GUIDE SPECS. TVR 5G GUIDE SPECS - JUL.2014 Page 1

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

Inverter Wall Mounted Series

Air-water heat pump. Hydronic terminals. HYDROLution NEW 172 SINGLE HT 176 DUAL HT 178 MINI CHILLER 180 MODULAR CHILLER 182 WARM COIL 184 FAN COIL 186

2017 LINE UP MINI SPLITS CATALOG

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

YES Mini VRF Series RESIDENTIAL DC INVERTER VRF AIR-CONDITIONERS YOU CAN TRUST

Neosys Product catalogue

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

Variable Refrigerant Flow

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type. R410A50Hz Universal Outdoor Series Technical Manual LCAC/2016.

LOW STATIC HYDRONIC DUCTED UNIT

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

Lennox Mini-Split Systems Year-Round Comfort and Performance

Mini unitary chiller. Mini unitary chiller

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

Product Brochure Smart Power. Low Profile Ducted

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

A more comfortable, safe and sustainable world

3 rd Generation of VRV. The professional solution for your professional project

COOLROW Close control air conditioners for In-Row installation Cooling Capacity: kw

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

42GWC Hydronic Cassette Fan Coil Units

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

technical data Fan coil unit FWB small duct unit

Heat Pump Air Conditioning Systems

Product Specifications. Vertical Floor Consoles By First Co.

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79

MVD. Cassette 4 Ways FCU DC Service manual MUCS-W7. CL04417 to CL04419 English.

Modular Air Cooled Scroll Chillers

Inverter Ducted Air Conditioners

tons MTZ Rooftop Units Plug and Play comfort solutions for residential and commercial application

PRODUCT LINEUP VRF. For LIGHT COMMERCIAL & RESIDENTIAL, COMMERCIAL

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

Emad Chen. Head of Qatar Office Midea Commercial Air Conditioner

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

Chilled Water Precision Air Conditioner for Critical Application

AIR COOLED MINI CHILLER

WORLD LARGEST Air Conditioners Manufacturer PRODUCT CATALOGUE GREE MALAYSIA SDN BHD ( M)

Commercial Air Conditioners 2017/2018

2016 RESIDENTIAL AND LIGHT COMMERCIAL DUCTLESS

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

On the cover Integrated professional services designed for your unique business need.

Compact design & easy maintenance

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Integrated VarIable refrigerant flow ahu/pau (r410a)

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

HEAT PUMP HEAT RECOVERY / ULTRA HEAT RECOVERY MINI VRF / MINI VRF ULTRA HEAT VRF CATALOG. Variable Refrigerant Flow Solutions. TOSOT VRF Catalog 1


2008 Midea Commercial A/C

Engineering Data Book

Transcription:

Coercial Air Conditioners 07/08 INVERTER DC Inverter Aqua Mini Chillers &

Midea CAC Midea CAC is a key division of the Midea Group, a leading producer of consumer appliances and provider of heating, ventilation and air conditioning solutions. Midea CAC has continued with the tradition of innovation upon which it was founded, and emerged as a global leader in the HVAC industry. A strong drive for advancement has created a groundbreaking R&D department that has placed Midea CAC at the forefront of a competitive field. Through these independent efforts and joint cooperation with other global enterprises, Midea has supplied thousands of innovative solutions to customers worldwide. Midea Company Introduction Midea CAC Introduction

There are three production bases: Shunde, Chongqing and Hefei. MCAC Shunde: 38 product lines focusing on VRF, Split Products, Heat Pump Water Heaters, and AHU/FCU. MCAC Chongqing: 4 product lines focusing on Water Cooled Centrifugal/Screw/Scroll Chillers, Air Cooled Screw/Scroll Chillers, and AHU/FCU. MCAC Hefei: product lines focusing on VRF, Chillers, and Heat Pump Water Heaters. 06 Strategic alliance between Midea and Italy s Clivet 05 JV with Carrier in China in chiller field, launched the unitary all DC inverter type Aqua Mini Chiller 04 Launched the DC Inverter 03 Launched the super high efficiency centrifugal chiller with full falling film technology 0 Formed Midea-Carrier JV.Company in India and HK 00 Built the 3rd manufacturing base in Hefei 009 Launched the unitary fixed type Aqua Mini Chiller 008 Launched the split digital type Aqua Mini Chiller 006 Launched the first VSD centrifugal chiller 004 Acquired MGRE entered the chiller industry 00 Cooperated with Copeland to develop the digital scroll VRF system 000 Developed the first inverter VRF with Toshiba 999 Entered the CAC field

Aqua Mini Chiller Reference Projects Hotel ASEM Resort Villa Five Star Sheraton Bandara Resort Hotel Five Star Aston Kuta Bali Hotel Five Star Residential Vanke Estate Rancho Santa Fe Villas Al Sila'a Emirati Housing Development 448 Villas Agile Estate Clear Water Bay 03

INVERTER Aqua Mini Chiller Contents 05 07 4 5 5 30 3 34 38 39 4 4 Aqua Mini Chiller Features Specifications Unit Dimensions Cassette Series Duct Series Wall Mounted Ceiling & Floor Dimensions Control Devices Accessories Application of Central Control & BMS Control Selection Software 04

Aqua Mini Chiller Aqua Mini Chiller Midea DC Inverter Air-cooled Mini Chiller has unitary structure design and hydraulic module is built in the outdoor unit. It is air-cooled water heat pump chiller so there is no need of cooling water tower at the condensing side. DC inverter Mini chillers cooling capacity range is from 5 to 8 and it can freely combine with fan coil units and floor heating. These units are designed for residential applications or light coercial applications that require cold or hot water. They are silent and compact units, easy to install and maintain. All units energy efficiency at part load is A + rated. Their high energy efficiency and high reliability ensure low running cost. So they are widely applied in apartments, villas, small business office buildings as well as restaurants, etc. Product Lineup Capacity () 5 7 0 4 6 8 Appearance Power Supply 0-40V/Ph/50Hz 380-45V/3Ph/50Hz 08-30V/Ph/60Hz 05

Aqua Mini Chiller Nomenclature M G C - V 6 W / D R N Refrigerant type N: R40A Power Supply R: 380-45V/3Ph/50Hz None: 0-40V/Ph/50Hz D: DC compressor and fan motor Outdoor Unit Nominal Cooling Capacity () Compressor V: Inverter scroll compressor Design Series Code C: Unitary chiller Light Coercial Chiller System Midea 06

Aqua Mini Chiller Features Wide application range Nine models with cooling capacities from 5 to 8 and heating capacities from 5.5 to 8.5. Multiple power supply options. Freely combine with fan coil units and floor coils. Home owners may choose the best types according to their design taste (for interior) or functional needs. 4 way cassette Ceiling & floor Compact 4 way cassette Duct Wall mounted Wide operation temperature range -5 C COOLING MODE 46 C HEATING MODE -5 C 7 C -0-0 0 0 0 3 0 4 0 5 0 C(D.B.) Outdoor temp. Wide range of outlet water temperature The water outlet temperature is 4-55 C. 07

A + rated energy efficiency at part load The DC inverter chiller integrates the latest technological innovations and ensures precise temperature regulation and highly efficient energy usage, making a significant contribution to the limiting the impact on the environment. Aqua Mini Chiller DC inverter compressor Twin rotary DC inverter compressor is used. The output of the outdoor unit can be adjusted precisely according to the energy demanded. High efficiency DC motor: - Creative motor core design - High density neodymium magnet - Concentrated type stator - Wider operating frequency range Better balance and Extremely Low Vibration: - Twin eccentric cams - balance weights Compressor (Twin Rotary) structure Highly Stable Moving Parts: - Optimal material matching rollers and vanes - Optimize compressor drive technology - Highly robust bearings - Compact structure DC fan motor High efficiency DC fan motor saved power up to 50%. Motor speed(rpm) DC inverter stepless adjustment AC inverter multistep adjustment System pressure High performance heat exchanger Reduce air resistance New design Original design High efficiency inner-threaded pipe, enhance heat transfer. Hydrophilic fins + inner-threaded pipes The new designed window fins enlarge the heat-exchanging area, decrease the air resistance, save more power and enhance heat exchange performance. Hydrophilic film fins and inner-threaded copper pipes optimize heat exchange efficiency. The specially coated blue fins enhance durability and protect against corrosion from air, water and other corrosive agents, assures a longer coil service life. 08

Aqua Mini Chiller Advanced technology DC inverter technology, optimally designed fan shape and air discharge grille ensure low sound values. Air deflector Grille Fan Powerful Large Propeller Newly Designed Fan Guard EXV is used for stable and accurate gas flow control. Refrigerant inlet High efficiency plate heat exchanger Water outlet Plate heat exchanger uses metal plates to transfer heat between refrigerant and water. The fluids are exposed to a much larger surface area because the fluids spread out over the plates, so both heat transfer efficiency and heat exchanger speed are greatly improved. Multi protections including voltage protection, current protection, anti-freezing protection and water flow protection ensure system Water inlet safety running. Refrigerant outlet High efficiency water pump The water pump used is compliance with Erp directive, which is A degrade efficiency standard. Easy installation Compact structure design and leak-tight refrigerant circuit save you much installation labor. The chillers are equipped with a hydronic module integrated into the unit chassis, limiting the installation to straight-forward operations like connection of the power supply, the water supply and the air distribution FCUs. The units are equipped with axial fans so they can be installed directly outdoors. Air purge valve Plate heat exchanger Pressure relief valve Hydraulic module Water pump Water pressure differential valve Expansion tank 09

Easy control Remote ON/OFF and remote cool/heat functions. Aqua Mini Chiller Controller built-in in unit panel used to perform all related operations as the user interface as well as fast diagnosis of possible incidents and their history. ON/OFF & Mode selection Temperature adjust Timer setting Fast diagnosis Optional wired controller for easy operation. Touch key operation LCD displays operation parameters Multiple timers Real-time clock Note: When the wired controller is connected, the built-in controller is only for display, check and diagnosis functions. 0

Aqua Mini Chiller Specifications 0-40V/Ph/50Hz Power supply Cooling Cooling Heating 3 Heating 4 Compressor Air heat exchanger V/Ph/Hz MGC-V5W/DN MGC-V7W/DN MGC-V0W/DN MGC-VW/DN 0-40//50 Capacity 5.0(.9-5.8) 7.0(.-7.8) 0.0(.9-0.5).(3.-.0) Rated input.55.6 3.03 3.50 Rated current A 6.8 9.9 3.0 5.4 3.3 3.0 3.30 3.0 4. 3.76 3.89 4.09 Capacity 5.6 8.0 0.6. Rated current.5 8.5 3.0 6.5 EER 4.87 4.3 4.4 4.60 Capacity 6.(.-7.0) 8.0(.3-9.0).0(3.-.0).3(3.3-3.) Rated input.90.54 3.4 3.78 Rated current A 8.3.0 3.8 6.6 COP 3.6 3.5 3.4 3.5 Capacity 6. 8.6.5 3.0 Rated current.35.0.65.9 COP SCOP Seasonal space heating energy efficiency (ηs) Seasonal space heating energy efficiency class Max. input current Outdoor fan Water heat exchanger Motor type 4.60 4.0 4.34 4.45 3.55 3.46 3.34 3.46 38.9% 35.3% 30.7% 35.4% A+ A+ A+ A+ A.4 3.7 5 9. Rotary DC Motor Air flow m 3 /h 5,00 5,00 7,000 7,000 Fin-coil Plate heat exchanger Water volume L 0.53 0.53 0.7 0.78 Water flow m 3 /h 0.86.0.7.9 5 5 8 8 Pump head m 5.5 5.5 8.5 8.5 Water pump Water volume L/min 4 4 4 4 Expansion tank volume L 3 3 R40A Refrigerant Charged volume.5.5.8.8 Throttle type EER SEER Sound power level Sound pressure level 5 Unit net dimension (W H D) Packing dimension (W H D) Net/ The Max. and Min. wate rinlet pressure 6 Electronic expansion valve 63 66 68 68 58 58 59 59 990 966 354 990 966 354 970,37 400 970,37 400,0,00 435,0,00 435,08,456 435,08,456 435 8/9 8/9 0/ 0/ 500/50 Pipe connections Water inlet/outlet inch -/4 -/4 Controller Electronic controller (standard), wired controller (optional) Ambient Cooling C -5-46 temperature range Heating C -5-7 Water outlet Cooling C 4-0 temperature range Heating C 30-55 Nominal capacity is based on the following conditions:. Condenser air in 35 C. Evaporator water in/out /7 C. Condenser air in 35 C. Evaporator water in/out 3/8 C 3. Evaporator air in 7 C C85% R.H., Condenser water in/out 40/45 C 4. Evaporator air in 7 C C85% R.H., Condenser water in/out 30/35 C 5. At m in open field fan side (sound pressure) 6. The maximum and minimum operating pressure values refer to the activation of the pressure switches 7. The above data test reference standard EN45:03; EN485:03; EN50564:0; EN0:0; (EU)No:8:03; (EU)No:83:03; OJ 04/C 07/0:04

380-45V/3Ph/50Hz MGC-VW/DRN MGC-V4W/DRN MGC-V6W/DRN Power supply V/Ph/Hz 380-45/ 3/50 Capacity.(3.-.0).5(3.3-4.0) 4.5(3.5-5.5) Rated input 3.38 3.9 4.68 Cooling Rated current A 5.5 6.4 7.7 EER 3.3 3.0 3.0 SEER 4.6 4.7 4.38 Capacity. 4. 5.6 Cooling Rated input W.60 3.0 3.60 EER 4.70 4.58 4.33 Capacity.3(3.3-3.) 3.8(3.5-5.4) 6.0(3.7-7.0) Rated input 3.7 4.5 4.85 Heating 3 Rated current A 6. 7.0 8.0 COP 3.3 3.5 3.30 Capacity 3.0 5. 6.5 Rated input 850 3350 390 Heating 4 COP 4.56 4.5 4. SCOP 3.66 3.78 3.39 Seasonal space heating energy efficiency (ηs) 43.5% 48.3% 3.6% Seasonal space heating energy efficiency class A+ A+ A+ Max. input current A 8.9 9.6 0. Compressor Rotary Outdoor fan Motor type DC motor Air flow m 3 /h 7,000 7,000 7,000 Air heat exchanger Fin-coil Plate Water heat Water volume L 0.78 0.78.06 exchanger Water flow m 3 /h.9.5.49 8 8 9 Water pump Pump head m 8.5 8.5 8.5 Water volume L/min 4 4 4 Expansion tank volume L 3 3 3 Refrigerant R40A Charged volume.8.9 3. Throttle type Electronic expansion valve Sound power level 68 70 7 Sound pressure level 5 6 6 6 Unit net dimension (W H D) 970,37 400 Packing dimension (W H D),08,456 435 Net/ 0/ / / The Max. and Min. water inlet pressure 6 500/50 Pipe connections Water inlet/outlet inch -/4 Controller Electronic controller (standard), wired controller (optional) Ambient Cooling C -5-46 temperature range Heating C -5-7 Water outlet Cooling C 4-0 temperature range Heating C 30-55 Nominal capacity is based on the following conditions:. Condenser air in 35 C, Evaporator water in/out /7 C. Condenser air in 35 C, Evaporator water in/out 3/8 C 3. Evaporator air in 7 C C85% R.H., Condenser water in/out 40/45 C 4. Evaporator air in 7 C C85% R.H., Condenser water in/out 30/35 C 5. At m in open field fan side (sound pressure) 6. The maximum and minimum operating pressure values refer to the activation of the pressure switches 7. The above data test reference standard EN45:03; EN485:03; EN50564:0; EN0:0; (EU)No:8:03; (EU)No:83:03; OJ 04/C 07/0:04 Aqua Mini Chiller

Aqua Mini Chiller 08-30V/Ph/60Hz MGC-V0W/DVN MGC-V8W/DVN Power supply V/Ph/Hz 08-30//60 kbtu/h 36.0(0.0-37.0) 58.0(3.0-6.0) Capacity 0.0(.9-0.5) 7.0(3.8-8.0) Cooling Input 3. 5.60 EER 3.39 3.0 Heating kbtu/h 38.0(.0-4.0) 63.0(4.0-65.0) Capacity.0(3.-.0) 8.5(4.0-9.0) Input 3.4 5.78 COP 3.50 3.0 Max. input current Compressor A 8.9 9.6 Rotary Outdoor fan Motor type DC motor Air flow CFM(m 3 /h) 4,0(7,000) 4,0(7,000) Air heat exchanger Fin-coil Plate Water heat exchanger Water volume L 0.7.06 Water flow CFM(m 3 /h).0(.7).7(.9) 8 3 Water pump Expansion tank volume Refrigerant Throttle type Sound pressure level 3 Pump head m 8 8 Water volume L/min 4 4 L 3 3 R40A Charged volume lbs/ 6./.8 7.5/3.4 Electronic expansion valve 56 60 Unit net dimension (W H D) Packing dimension (W H D) inch inch 38-3/6 5-/4 3-/ 970,37 400 4-9/3 57-/64 7-/8,08,456 435 Net/ lbs 43/67 47/7 0/ /3 The Max. and Min. wate rinlet pressure 4 500/50 Pipe connections Water inlet/outlet inch Controller -/4 Electronic controller (standard), wired controller (optional) Ambient temperature range Water outlet temperature range Cooling C Heating C Cooling C Heating C -5-46 -5-7 4-0 30-55. Cooling: Chilled water inlet/outlet temperature: /7 C, outdoor ambient temperature 35 C DB.. Heating: Warm water inlet/outlet temperature: 40/45 C, outdoor ambient temperature 7 C DB/6 C WB. 3. At m in open field fan side (sound pressure). 4. The maximum and minimum operating pressure values refer to the activation of the pressure switches. 3

Unit Dimensions (Unit: ) 5/7 Aqua Mini Chiller 66 0-8 37 363 339 435 390 963 995 00 600 340 30 360 400 900 970 4

Midea DC operate in high efficiency and low sound level due to the DC brushless fan motor. It contains cassette units, ceiling & floor units with or without cabinet, wall-mounted units and duct units. The air volume ranges from 50CFM to 500CFM. It is a highly versatile product suitable for hospitals, office buildings, hotels, airports and various other applications. 5

Nomenclature M K T3 - V 00 Nominal Air Volume (CFM) DC Series Code Chilled Fan Coil Unit Midea 6

Advantage of with DC Brushless Fan Motor The DC fan coil units are the new energy saving products improved with advanced DC driven technology. The DC fan coil units have advanced technology of high energy efficiency, low noise operation and precision temperature control, so are ideal for hospitals, office building, hotels, airports and various other applications. DC driven motor Energy Efficiency, Comply with CE Regulation The power consumption of DC driven fan coil units can be reduced up to 30% in comparison to corresponding AC type. Power input: W DC motor 00 AC motor 50 00 50 0 00 300 400 500 600 800 000 00 Air Flow: CFM DC and AC motor s power contrast 7

Quiet Operation Unit noise is -5 lower compared to an AC motor fan coil unit, creating a quiet living environment. Quiet Constant Level of Air Temperature and Humidity The DC Inverter fan motor adjusts of air flow based on thermal load instantly providing less temperature fluctuation and an improved living environment. Temp Fluctuation of room temperature Time DC driven FCU AC driven FCU Versatile Selection Midea DC contain cassette units, ceiling & floor units with or without cabinet, wall-mounted units and duct units. The air volume ranges from 50CFM to 500CFM. It is a highly versatile product suitable for hospitals, office buildings, hotels, airports and various other applications. Cassette unit Wall-mounted unit Duct unit Ceiling & floor unit with cabinet Ceiling & floor unit with cabinet Ceiling & floor unit without cabinet 8

Product Lineup -Pipe FCUs Air volume (CFM) 50 00 50 300 400 450 500 4-way cassette Compact 4-way cassette Duct Wall mounted Ceiling & floor 4-Pipe FCUs Air volume (CFM) 00 300 400 500 600 750 800 4-way cassette Compact 4-way cassette Duct Note: The standard power supply for all fan coil units is 0V-40V/50Hz; 08-30V/60Hz can be customized for all fan coil units. 9

600 750 800 850 900 950 000 00 500 850 950 000 00 500 0

Cassette Series 4-way Cassette Compact 4-way Cassette -pipe 4-pipe -pipe 4-pipe Various Selections Versions for /4 pipe systems. Versions for compact/normal size. Stylish Panel with Large Airflow Outlet 4-way air supply panel is standard for 4-way cassette. 360 air supply panel is standard for compact 4-way cassette. 4-way panel 360 panel Compact Design, Easy Installation For Compact Four-way Cassette: Extremely compact casing suits any room's decor and requires little space for installation on a low ceiling. Due to compact body and light weight, all models can be installed without a hoist. 575 575 6 High Efficiency and Low Sound Operation Thanks to the DC brushless fan motor, the unit operates in high efficiency and low sound level. Various Accessories Selections Safe factory-installed electric heater is optional. Extended drainage pan for better ceiling protection is optional. High-lift Drain Pump Standard built-in drain pump with 750 pump head for normal size and 500 for compact size. 750 Fresh Air Intake Fresh air can enter through the cassette unit so you can enjoy even fresher air in a room.

-Pipe 4-Way Cassette Power supply Air flow (H/M/L) Cooling Water flow rate Heating Power input (H) Sound pressure level (H/M/L) Fan motor Fan Row Coil Max. working pressure Diameter Packing size (W H D) Panel Net weight Packing size (W H D) Body Net weight Pipe Water inlet/outlet pipe connections Drain pipe V/Ph/Hz m 3 /h CFM L/h W MPa inch MKA-V600R 33/793/567 667/467/334 5.58/4.35/3.5 960 7.7/5.9/4.5 4 4/33/6 840 30 840 900 60 900 3 8 MKA-V750R 0-40//50 55/879/68 739/57/370 5.77/4.5/3.63 99 8 8.5/6./4.65 6 50 45/37/8 DC motor Centrifugal, forward-curved blades.6 Φ7 950 45 950 035 90 035 6 9 840 30 840 900 60 900 3 8 RC3/4 ODΦ3 MKA-V850R 44/009/7 848/594/44 6.84/5.33/4.3 76 7 9.37/7.5/5.5 3 64 46/36/8 840 300 840 900 330 900 7 33 Power supply Air flow (H/M/L) Cooling Water flow rate Heating Power input (H) Sound pressure level (H/M/L) Fan motor Fan Row Coil Max. working pressure Diameter Packing size (W H D) Panel Net weight Packing size (W H D) Body Net weight Pipe Water inlet/outlet pipe connections Drain pipe V/Ph/Hz m 3 /h CFM L/h W MPa inch MKA-V950R 494/046/747 879/66/440 6.99/5.7/4.6 0 5 9.5/7.35/5.3 0 7 47/37/3 7 33 MKA-V00R 0-40//50 596/7/798 940/657/470 7.0/5.3/4.34 06 3 9.6/7.43/5.55 0 90 48/39/3 DC motor Centrifugal, forward-curved blades.6 Φ7 950 45 950 035 90 035 6 9 840 300 840 900 330 900 7 33 RC3/4 ODΦ3 Notes:. H: High fan speed; M: Medium fan speed; L: Low fan speed.. Cooling conditions: entering water 7 C, temperature rise 5 C, entering air temperature 7 C DB/9 C WB. Heating conditions: entering water 50 C, entering air temperature 0 C DB, the same water flow as the cooling conditions. 3. Noise is tested in a semi-anechoic test room. MKA-V500R 850/95/95 089/76/544 0.64/8.09/6.6 830 36 4.38/.9/8.44 34 4 50/40/33 3 9.5 34.5

4-Pipe 4-Way Cassette Power supply Air flow (H/M/L) Cooling Water flow rate Heating Water flow rate Power input (H) Sound pressure level (H/M/L) Fan motor Fan Row Coil Max. working pressure Diameter Packing size (W H D) Panel Net weight Packing size (W H D) Body Net weight Pipe Water inlet/outlet pipe connections Drain pipe V/Ph/Hz m 3 /h CFM L/h L/h W MPa inch MKA-V600F 87/83/594 700/489/350 4.94/3.77/3.3 850 5 7.4/5.4/4.5 64 40 47 40/3/5 MKA-V750F 0-40//50 33/863/67 76/508/363 5.8/3.94/3.6 89 7.4/5.64/4.67 637 4 50 4/34/6 DC motor Centrifugal, forward-curved Blades.6 Φ7 950 45 950 035 90 035 6 9 840 300 840 900 330 900 7.5 33.5 Cold water: RC3/4; Hot water: RC/ ODΦ3 MKA-V850F 436/005/78 845/59/43 5.9/4.0/3.33 90 7.88/5.99/4.97 678 45 64 43/34/7 Power supply Air flow (H/M/L) Cooling Water flow rate Heating Water flow rate Power input (H) Sound pressure level (H/M/L) Fan motor Fan Row Coil Max. working pressure Diameter Packing size (W H D) Panel Net weight Packing size (W H D) Body Net weight Pipe Water inlet/outlet pipe connections Drain pipe V/Ph/Hz m 3 /h CFM L/h L/h W MPa inch MKA-V950F 56/068/763 898/69/449 5.6/4.6/3.53 965 5 8.4/6.6/5.9 709 49 7 45/35/9 7.5 3.4 Notes:. H: High fan speed; M: Medium fan speed; L: Low fan speed.. Cooling conditions: entering water 7 C, temperature rise 5 C, entering air temperature 7 C DB/9 C WB. Heating conditions: entering water 70 C, temperature drop 0 C DB, entering air temperature 0 C DB. 3. Noise is tested in a semi-anechoic test room. MKA-V00F 0-40//50 768/38/884 04/79/50 9.0/6.85/5.68 55 70.3/8.59/7. 973 63 06 46/37/3 DC motor Centrifugal, forward-curved Blades 3.6 Φ7 950 45 950 035 90 035 6 9 840 300 840 900 330 900 30 35 Cold water: RC3/4; Hot water: RC/ ODΦ3 MKA-V500F 85/33/945 /779/556 9.6/7.3/6.07 576 7.88/9.8/7.69 0 7 4 48/39/33 3 30 35 3

-Pipe Compact 4-Way Cassette Power supply Air flow (H/M/L) Cooling Water flow rate Heating Power input (H) Sound pressure level (H/M/L) Fan motor Fan Row Coil Max. working pressure Diameter Packing size (W H D) Panel Net weight Packing size (W H D) Body Net weight Pipe Water inlet/outlet pipe connections Drain pipe V/Ph/Hz m 3 /h CFM L/h W MPa inch 4-Pipe Compact 4-Way Cassette Power supply Air flow (H/M/L) Cooling Water flow rate Heating Water flow rate Power input (H) Sound pressure level (H/M/L) Fan motor Fan Row Coil Max. working pressure Diameter Packing size (W H D) Panel Net weight Packing size (W H D) Body Net weight Pipe Water inlet/outlet pipe connections Drain pipe V/Ph/Hz m 3 /h CFM L/h L/h W MPa inch MKD-V300 560/39/80 330/3/65 3.0/.3/.75 59 7.4 4./3/. 8.7 34/9/ MKD-V300F 560/397/84 334/34/67.39/.8/.46 4 9. 3.9/.98/.47 337 0.5 5 34/6/0 MKD-V400 0-40//50 77/50/359 4/96/ 3.93/3.07/.48 676 5.34/4/3.5 0.6 7 40/36/8 DC motor Centrifugal, forward-curved Blades.6 Φ7 647 50 647 75 3 75.5 4.5 575 6 575 675 30 675 6.5.5 G3/4 ODΦ5 MKD-V400F 0-40//50 77/50/359 4/86/.88/.9/.8 495 4.5 4.73/3.6/.98 407 9. 7 36/8/ DC motor Centrifugal, forward-curved Blades.6 Φ7 647 50 647 75 3 75.5 4.5 575 6 575 675 30 675 6.7.7 Cold water: G3/4; Hot water: G/ ODΦ5 Notes:. H: High fan speed; M: Medium fan speed; L: Low fan speed.. Cooling conditions: entering water 7 C, temperature rise 5 C, entering air temperature 7 C DB/9 C WB. Heating conditions: pipe: entering water 50 C, entering air temperature 0 C DB, the same water flow as the cooling conditions. Heating conditions: 4 pipe: entering water 70 C, temperature drop 0 C DB, entering air temperature 0 C DB. 3. Noise is tested in a semi-anechoic test room. MKD-V500 850/730/600 500/430/350 4.5/3.6/3.06 774 6 6/4.76/4.07 5 3 43/37/30 MKD-V500F 785/550/393 46/34/3 3.4/.46/.04 558 0.9 4.93/3.75/3. 44 34.5 39 40/3/5 4

Duct Series -Pipe Duct 4-Pipe Duct Various Selections Versions for normal/high temperature different systems., 3 or 4 row coils for -pipe system, and 3 row coils for 4-pipe system. Large range of available static pressure. High Efficiency and Low Sound Operation Due to the DC brushless fan motor, the unit operates in high efficiency and low sound level. Flexible Installation Left and right hand piping connections are optional, flexible installation. Left hand Front discharge Right hand Standard Return Air Plenum and Filter Standard return air plenum and filter guarantees clean air supply and stable air flow rate. Fresh Air Intake Fresh air can enter through the duct unit so you can enjoy even fresher air in the room. 5

-Pipe -Row Duct Power supply Air flow (H/M/L) Standard external static pressure Cooling Water flow rate Heating Power input (H) Sound pressure level Fan motor Fan Coil Packing size (W H D) Net weight Water inlet/outlet pipe Drain pipe Pa (H/M/L) 30Pa (H/M/L) 50Pa (H/M/L) Row Max. working pressure Diameter V/Ph/Hz m 3 /h CFM Pa L/h W MPa inch MKT-V00 340/55/70 00/50/00 /.74/.5 344 6. 3./.75/.37 5.6 0 35/3/5 40/36/9 43/39/3 74 4 5 790 60 550 6.5 9 MKT-V300 50/385/55 300/5/50 0-40//50 Pa (default), 30/50Pa can be set through dial switch on PCB.7/.3/.03 464.4 4.3/3.74/3.3 9.7 6 36/33/6 4/37/30 44/40/3 DC motor Centrifugal, forward-curved Blades.6 Φ9.5 84 4 5 890 60 550 8.5.4 RC3/4 R3/4 MKT-V400 680/50/340 400/300/00 3.6/3./.66 69 0.4 5.4/4.64/4.05 7.7 38 37/34/7 4/38/3 45/4/33 94 4 5 990 60 550 0 3. MKT-V500 850/640/45 500/375/50 4.4/3.74/3.5 757 0. 6.8/5.78/5.07 8.9 48 38/35/8 43/39/3 46/4/34 94 4 5 990 60 550 0 3. Power supply Air flow (H/M/L) Standard external static pressure Cooling Water flow rate Heating Power input (H) Sound pressure level Fan motor Fan Coil Packing size (W H D) Net weight Water inlet/outlet pipe Drain pipe Pa (H/M/L) 30Pa (H/M/L) 50Pa (H/M/L) Row Max. working pressure Diameter V/Ph/Hz m 3 /h CFM Pa L/h W MPa inch MKT-V600 00/765/50 600/450/300 5.5/4.58/4.09 946 3.9 8./6.77/5.9.6 54 39/36/9 44/40/33 47/43/35 6 4 5 0 60 550. 6 MKT-V800 360/00/680 800/600/400 7.5/6.33/5.68 90.4 /9.48/8.5 0.6 74 40/37/30 45/4/34 48/44/36 DC motor Centrifugal, forward-curved Blades 4 4.6 Φ9.5 46 4 5 50 60 550 3.4 35.8 0-40//50 MKT-V000 700/75/850 000/750/500 Pa (default), 30/50Pa can be set through dial switch on PCB RC3/4 R3/4 8.9/7.6/6.4 53.4 3.5/.7/0.03 8.4 99 4/39/3 46/4/34 50/45/37 566 4 5 65 60 550 3.5 37. MKT-V00 040/530/00 00/900/600 0.8/9.3/7.93 858 8. 6.5/4.05/.4.8 35 44/40/33 47/43/34 50/46/38 4 856 4 5 905 60 550 37.5 4.8 Notes:. H: High fan speed; M: Medium fan speed; L: Low fan speed.. Air flow rate at 0Pa ESP. 3. Cooling conditions: entering water 7 C, temperature rise 5 C, entering air temperature 7 C DB/9 C WB. Heating conditions: entering water 50 C, entering air temperature 0 C DB, the same water flow as the cooling conditions. 4. Noise is tested in a semi-anechoic test room. 6

-Pipe 3-Row Duct Power supply Air flow (H/M/L) Standard external static pressure Cooling Water flow rate Heating Power input (H) Sound pressure level Fan motor Fan Coil Packing size (W H D) Net weight Water inlet/outlet pipe Drain pipe Pa (H/M/L) 30Pa (H/M/L) 50Pa (H/M/L) Row Max. working pressure Diameter V/Ph/Hz m 3 /h CFM Pa L/h W MPa inch MKT3-V00 340/55/70 00/50/00./.9/.68 378 9.4 3.5/3.08/.59 8. 6 36/3/6 40/36/9 4/39/3 74 4 5 790 60 550 6.7 9.7 MKT3-V300 50/385/55 300/5/50 0-40//50 Pa (default), 30/50Pa can be set through dial switch on PCB 3./.7/.3 533 0.6 5.3/4.6/3.98 6.8 37/33/6 4/38/30 43/40/3 DC motor Centrifugal, forward-curved Blades 3.6 Φ9.5 84 4 5 890 60 550 9 RC3/4 R3/4 MKT3-V400 680/50/340 400/300/00 4/3.4/.95 688 9.7 6.8/5.85/5..4 8 37/34/7 4/38/3 45/4/33 94 4 5 990 60 550 4 MKT3-V500 850/640/45 500/375/50 4.5/3.96/3.45 774 7.5 7.9/6.95/6 4.8 40 38/35/8 43/38/3 45/4/34 94 4 5 990 60 550 4 Power supply Air flow (H/M/L) Standard external static pressure Cooling Water flow rate Heating Power input (H) Sound pressure level Fan motor Fan Coil Packing size (W H D) Net weight Water inlet/outlet pipe Drain pipe Pa (H/M/L) 30Pa (H/M/L) 50Pa (H/M/L) Row Max. working pressure Diameter V/Ph/Hz m 3 /h CFM Pa L/h W MPa inch MKT3-V600 00/765/50 600/450/300 5.8/4.88/4.45 998 30. 9.8/8.6/7.4 5 45 39/36/9 44/40/33 47/43/35 6 4 5 0 60 550 3.7 7. MKT3-V800 360/00/680 800/600/400 8./6.88/6.5 40 30.4 3.6/.97/0. 6.8 60 4/37/30 45/40/34 47/44/36 DC motor Centrifugal, forward-curved Blades 4 4 3.6 Φ9.5 46 4 5 50 60 550 33 37. 0-40//50 MKT3-V000 700/75/850 000/750/500 Pa (default), 30/50Pa can be set through dial switch on PCB RC3/4 R3/4 9/7.8/6.57 548.8 5.5/4.4/ 8.4 90 4/39/3 46/4/34 50/45/37 566 4 5 65 60 550 34.7 39. MKT3-V00 040/530/00 00/900/600 /9.8/8.35 89.7 0./8.7/5.43 9.9 0 44/40/33 47/4/34 50/45/38 4 856 4 5 905 60 550 39. 44.4 Notes:. H: High fan speed; M: Medium fan speed; L: Low fan speed.. Air flow rate at 0Pa ESP. 3. Cooling conditions: entering water 7 C, temperature rise 5 C, entering air temperature 7 C DB/9 C WB. Heating conditions: entering water 50 C, entering air temperature 0 C DB, the same water flow as the cooling conditions. 4. Noise is tested in a semi-anechoic test room. 7

-Pipe 4-Row Duct Power supply Air flow (H/M/L) Standard external static pressure Cooling Water flow rate Heating Power input (H) Sound pressure level Fan motor Fan Coil Packing size (W H D) Net weight Water inlet/outlet pipe Drain pipe Pa (H/M/L) 30Pa (H/M/L) 50Pa (H/M/L) Row Max. working pressure Diameter V/Ph/Hz m 3 /h CFM Pa L/h W MPa inch MKT4-V00 340/55/70 00/50/00.5/.6/.87 430 4./3.5/3.03 5.6 0 37/33/7 4/36/30 43/39/3 74 4 5 790 60 550 7.8 0.4 MKT4-V300 50/385/55 300/5/50 0-40//50 Pa (default), 30/50Pa can be set through dial switch on PCB 3.3/.85/.47 568 4.8 5.8/5.05/4.35 9.7 6 37/33/6 4/38/30 43/40/3 DC motor Centrifugal, forward-curved Blades 4.6 Φ9.5 84 4 5 890 60 550 0.9 RC3/4 R3/4 MKT4-V400 680/50/340 400/300/00 4.4/3.7/3. 757 9.3 7./6./5.33 7.7 38 38/35/7 4/38/3 45/4/33 94 4 5 990 60 550.9 5. MKT4-V500 850/640/45 500/375/50 4.8/4.8/3.64 86 9.6 8.5/7.04/6.8 8.9 48 38/35/8 43/38/3 46/4/34 94 4 5 990 60 550.9 5. Power supply Air flow (H/M/L) Standard external static pressure Cooling Water flow rate Heating Power input (H) Sound pressure level Fan motor Fan Coil Packing size (W H D) Net weight Water inlet/outlet pipe Drain pipe Pa (H/M/L) 30Pa (H/M/L) 50Pa (H/M/L) Row Max. working pressure Diameter V/Ph/Hz m 3 /h CFM Pa L/h W MPa inch MKT4-V600 00/765/50 600/450/300 6./5.38/4.65 066 8.8 0.5/9.03/7.77.6 54 39/36/9 44/40/33 47/43/35 6 4 5 0 60 550 5 8.8 MKT4-V800 360/00/680 800/600/400 8.8/7.43/6.57 54.5 4.5/.38/0.88 0.6 74 4/37/30 45/40/34 47/44/36 DC motor Centrifugal, forward-curved Blades 4 4 4.6 Φ9.5 46 4 5 50 60 550 34.8 39. 0-40//50 MKT4-V000 700/75/850 000/750/500 Pa (default), 30/50Pa can be set through dial switch on PCB RC3/4 R3/4 9.5/8.8/7.06 634 4.5 6.3/3.45/.05 8.4 99 4/39/3 46/4/35 50/45/37 566 4 5 65 60 550 36.4 4.9 MKT4-V00 040/530/00 00/900/600.8/9.8/8.74 030 3. 0./6.7/4.88.8 35 44/40/33 47/4/35 50/45/38 4 856 4 5 905 60 550 4.9 47. Notes:. H: High fan speed; M: Medium fan speed; L: Low fan speed.. Air flow rate at 0Pa ESP. 3. Cooling conditions: entering water 7 C, temperature rise 5 C, entering air temperature 7 C DB/9 C WB. Heating conditions: entering water 50 C, entering air temperature 0 C DB, the same water flow as the cooling conditions. 4. Noise is tested in a semi-anechoic test room. 8

4-Pipe 3-Row Duct MKT3- Power supply Air flow (H/M/L) Standard external static pressure Cooling Heating Power input Sound pressure level Fan motor Fan Coil Net Dimensions (W H D) Packing size (W H D) Net weight Water inlet/outlet pipe Drain pipe V00F V300F V400F V500F V/Ph/Hz 0-40//50 0-40//50 0-40//50 0-40//50 m 3 /h 30/0/40 450/340/80 530/390/60 690/470/370 CFM 90/0/85 70/00/70 30/30/60 40/80/0 Pa.4/./0.8./.7/.5.5/.0/.5 3.0/.4/.9 Water flow rate L/h 70 380 470 540 0. 0.5.3 3.6./.7/.4 3.0/.6/. 3.7/3./.5 4.4/3.6/3.0 8.9 9. 0..7 W 4 9 4 36 Pa (H/M/L) 35/5/3 36/9/3 38/3/4 43/35/7 30Pa (H/M/L) 4/3/5 39/30/5 44/38/8 46/37/30 50Pa (H/M/L) 43/34/6 44/36/6 47/4/8 48/4/33 Row Max. Working pressure Diameter Pa (default), 30/50Pa can be set through dial switch on PCB. DC Motor DC Motor DC Motor DC Motor Centrifugal, forward-curved Blades 3 3 3 3 MPa.6.6.6.6 Φ9.5 Φ9.5 Φ9.5 Φ9.5 74 4 5 84 4 5 94 4 5 94 4 5 790 60 550 890 60 550 990 60 550 7. 9.5.5.5 0..5 4.5 4.5 inch RC3/4 RC3/4 RC3/4 RC3/4 ODΦ4 ODΦ4 ODΦ4 ODΦ4 MKT3- Power supply Air flow (H/M/L) Standard external static pressure Cooling Heating Power input Sound pressure level Fan motor Fan Coil Net Dimensions (W H D) Packing size (W H D) Net weight Water inlet/outlet pipe Drain pipe. H: High fan speed; M: Medium fan speed; L: Low fan speed.. Air flow rate at Pa ESP. 3. Cooling conditions: entering water 7 C, temperature rise 5 C, entering air temperature 7 C WB/9 C DB. Heating conditions: entering water 50 C, entering air temperature 0 C, the same water flow as the cooling conditions. 4. Noise is tested in a semi-anechoic test room. V600F V800F V000F V00F V/Ph/Hz 0-40//50 0-40//50 0-40//50 0-40//50 m 3 /h 900/670/440 40/840/670 60/60/790 850/400/970 CFM 530/400/60 730/500/400 950/690/470 090/830/570 Pa 4./3.5/.5 5.3/4./3. 6.7/5.4/3.9 8./6.5/4.6 Water flow rate L/h 730 930 80 400 5.3.8.6 34.9 5.7/4.8/3.4 6.8/5.5/4.6 8./6.9/5. 0./8.6/6.8.7.0 5.5 5.73 W 45 57 87 95 Pa (H/M/L) 46/39/30 46/38/30 48/4/3 47/40/30 30Pa (H/M/L) 49/4/33 49/43/33 49/4/33 50/4/34 50Pa (H/M/L) 5/44/39 5/45/37 5/44/35 53/45/37 Row Max. Working pressure Diameter Pa (default), 30/50Pa can be set through dial switch on PCB. DC Motor DC Motor DC Motor DC Motor Centrifugal, forward-curved Blades 4 4 4 3 3 3 3 MPa.6.6.6.6 Φ9.5 Φ9.5 Φ9.5 Φ9.5 6 4 5 46 4 5 566 4 5 856 4 5 0 60 550 50 60 550 65 60 550 905 60 550 4. 33.5 35. 39.7 7.7 37.7 39.7 44.9 inch RC3/4 RC3/4 RC3/4 RC3/4 R3/4 R3/4 R3/4 R3/4 9

Wall Mounted C S Stylish Panel Stylish front panel blends easily within any interior décor, ideal for use in shops, restaurants or offices with no or narrow false ceilings. High Efficiency and Low Sound Operation Due to the DC brushless fan motor, the unit operates in high efficiency and low sound level. Convenient Installation Multi-directional outlet pipe feature: left\right\rear, to meet the needs of different rooms. Rear Left Right Built-In 3-Way Electromagnetic Valve Auto Swing Louver The Auto Swing Louver function ensures that the air direction corresponds to the mode selected. Easy Maintenance Removable front panel making maintenance convenient. Step Swing 3 4 Open panel 30

Wall Mounted (C ) Power supply Air flow (H/M/L) Cooling Water flow rate Heating Power input (H) Sound pressure level Fan motor Fan Row Coil Max. working pressure Diameter Packing size (W H D) Net weight Water inlet/outlet pipe Drain pipe V/Ph/Hz m 3 /h CFM L/h W MPa inch MKG-V50 45/40/30 50/4/88./.84/.64 378 3. 3.0/.85/.35 0.7 30/6/3 95 90 0 00 385 300 5.6 MKG-V300 50/47/349 300/5/05.64/.48/.06 454 33.6 3.69/.9/.49 3.4 4.3 3/8/5 95 90 0 00 385 300 5.6 MKG-V400 0-40//50 680/550/504 400/34/97 3.08/.90/.66 530 4 4.34/3.77/3.35 40 33 36/3/9 DC motor Tangential fan.6 Φ7 95 90 0 00 385 300 5.6 G3/4 ODΦ0 MKG-V500 850/69/586 500/407/345 4.07/3.78/3.05 700 34.9 5.69/4.4/3.63 9.7 8 38/34/30 070 35 0 80 40 300 4.7 8.6 MKG-V600 00/80/670 600/483/394 4.45/3.95/3. 765 36.3 6.30/5.7/4.8 3.8 37.5 40/36/3 070 35 0 80 40 300 4.8 8.8 Wall Mounted (S ) Power supply Air flow (H/M/L) Cooling Water flow rate Heating Power input (H) Sound pressure level Fan motor Fan Row Coil Max. working pressure Diameter Packing size (W H D) Net weight Water inlet/outlet pipe Drain pipe V/Ph/Hz m 3 /h CFM L/h W MPa inch MKG-V50B 45/40/30 50/4/88.63/./.97 45 3. 3.36/.85/.35 0.7 30/6/3 95 90 30 00 390 35.7 7.3 MKG-V300B 50/47/349 300/5/05.97/.48/.06 5 33.6 3.9/.9/.49 3.4 4.3 3/8/5 95 90 30 00 390 35.7 7.6 MKG-V400B 0-40//50 680/550/504 400/34/97 3.8/.90/.66 564 4 4.37/3.77/3.35 40 33 36/3/9 DC motor Tangential fan.6 Φ7 95 90 30 00 390 35.7 6.3 G3/4 ODΦ0 MKG-V500B 850/69/586 500/407/345 4.5/3.78/3.05 73 34.9 5.8/4.4/3.63 9.7 8 38/34/30 07 35 30 80 45 35 5. 9 MKG-V600B 00/80/670 600/483/394 5.0/3.95/3. 860 36.3 6.7/5.7/4.8 3.8 37.5 40/36/3 07 35 30 80 45 35 4.9 8.6 Notes:. H: High fan speed; M: Medium fan speed; L: Low fan speed.. Cooling conditions: entering water 7 C, temperature rise 5 C, entering air temperature 7 C DB/9 C WB. Heating conditions: entering water 50 C, entering air temperature 0 C DB, the same water flow as the cooling conditions. 3. Noise is tested in a semi-anechoic test room. 3

Ceiling & Floor Concealed H3 Series Exposed (air return from side) H4 Series Exposed (air return from bottom) H5 Series High Efficiency and Low Sound Operation Due to the DC brushless fan motor, the unit operates in high efficiency and low sound level. Flexible Installation Cabinet and concealed versions meet various installation requirements. Horizontal or vertical installation. Floor installation Ceiling installation Flexible Air Return Air return can be from side or bottom. Movable Louver Removable louver making maintenance convenient. 3

Ceiling & Floor Power supply Air flow (H/M/L) Cooling Water flow rate Heating Power input (H) H3 (H/M/L) Sound pressure level H4 (H/M/L) H5 (H/M/L) Fan motor Fan Row Coil Max. working pressure Diameter Body Packing size (W H D) (H3 series) Net weight Body Packing size (W H D) (H4/H5 series) Net weight Water inlet/outlet pipe Drain pipe V/Ph/Hz m 3 /h CFM L/h W MPa inch MKH3-V50 MKH4-V50 MKH5-V50 55/5/90 50/5/0.5/0.87/0.69 98 8.5.5/.06/0.93 8 4 9/5/9 30/6/0 9/5/9 3 550 545 639 639 305 7 9 800 59 0 889 683 3 4.4 8.4 MKH3-V50 MKH4-V50 MKH5-V50 45/360/30 50/0/90.87/.50/.0 3 9.6.53/.9/.47 7.7 6 30/6/0 3/7/ 30/6/0 DC motor Centrifugal, forward-curved Blades 3.6 Φ9.5 550 545 639 639 305 7 9 800 59 0 889 683 3 4.4 8.4 0-40//50 G3/4 ODΦ6 MKH3-V300 MKH4-V300 MKH5-V300 50/430/380 300/50/0.53/.97/.45 435 6.3 3.49/.63/.89 4.5 9 3/8/ 33/9/3 3/8/ 750 545 839 639 305 0 3.5 000 59 0 089 683 3 8. 33. MKH3-V400 MKH4-V400 MKH5-V400 680/580/50 400/340/300 3.7/.60/.86 56 9.3 4.58/3.49/.47 6.6 33 34/30/4 35/3/5 34/30/4 750 545 839 639 305 0 3.5 000 59 0 089 683 3 8. 33. Power supply Air flow (H/M/L) Cooling Water flow rate Heating Power input (H) H3 (H/M/L) Sound pressure level H4 (H/M/L) H5 (H/M/L) Fan motor Fan Row Coil Max. working pressure Diameter Body Packing size (W H D) (H3 series) Net weight Body Packing size (W H D) (H4/H5 series) Net weight Water inlet/outlet pipe Drain pipe V/Ph/Hz m 3 /h CFM L/h W MPa inch MKH3-V450 MKH4-V450 MKH5-V450 765/650/570 450/380/335 3.97/.88/.6 683 30. 5.64/4.03/3.04 5.3 9 36/3/6 37/33/7 36/3/6 3 950 545 039 639 305 5 9 00 59 0 89 683 3 34. 39.7 MKH3-V500 MKH4-V500 MKH5-V500 850/70/640 500/40/375 4.85/3.6/.6 834 7.7 6.98/5./3.67 3. 35 38/33/7 39/34/8 38/33/7 3 950 545 039 639 305 5 9 00 59 0 89 683 3 34. 39.7 MKH3-V600 MKH4-V600 MKH5-V600 0-40//50 00/870/765 600/50/450 5.64/4.0/3.06 970 6.6 8.3/6.0/4.54 4.5 39 40/34/8 4/35/9 40/34/8 DC motor Centrifugal, forward-curved Blades 3.6 Φ9.5 50 545 339 639 305 3 36 500 59 0 589 683 3 40 45.5 G3/4 ODΦ6 Notes:. H: High fan speed; M: Medium fan speed; L: Low fan speed.. Cooling conditions: entering water 7 C, temperature rise 5 C, entering air temperature 7 C DB/9 C WB. Heating conditions: entering water 50 C, entering air temperature 0 C DB, the same water flow as the cooling conditions. 3. Noise is tested in a semi-anechoic test room. MKH3-V800 MKH4-V800 MKH5-V800 360/60/00 800/680/600 6.5/5.9/4.00 6.5 9.58/7.58/5.68 9.8 70 4/35/9 4/36/30 4/35/9 3 50 545 339 639 305 3 36 500 59 0 589 683 3 40 45.5 MKH3-V900 MKH4-V900 MKH5-V900 530/300/50 900/760/675 7.85/6.08/4.9 8 3.4.69/8.7/6.97 5.6 6 43/37/3 44/38/3 43/37/3 3 50 545 339 639 305 3 36 500 59 0 589 683 3 40 45.5 33

Dimensions 4-way cassette -pipe 4-way cassette Dimensions (unit:) Tubing side Drain side 4-Pipe 4-way cassette Dimensions (unit:) Tubing side Drain side 680(Hook-location) 840(Body) 950(Panel) 90 300 0 50 60 0 680(Hook-location) 840(Body) 950(Panel) B A C D 780(Hook-location) 840(Body) 950(Panel) Size MKA-V600R MKA-V750R MKA-V950R MKA-V00R MAK-V500R A B C D 30 70 35 85 300 90 45 95 780(Hook-location) 840(Body) 950(Panel) Service Spaces (unit:) Drain pipe joint Water pipe joint Drain pipe joint Water pipe joint >000 >000 C 330 >330 >000 >000 Ceiling >500 Outlet Inlet Outlet 880 (ceiling hole) 600 (ceiling hole) Panel Ceiling 4000~500 Outlet Inlet 880 (ceiling hole) Outlet Ground -pipe 4-way cassette Ground 4-pipe 4-way cassette 34

Compact 4-way cassette -pipe compact 4-way cassette Dimensions (unit: ) Drain side Tubing side 4 53(Hook-location) 575(Body) 647(Panel) 6 90 3 545(Hook-location) 575(Body) 647(Panel) 4-pipe compact 4-way cassette Dimensions (unit: ) Drain side Tubing side 53(Hook-location) 575(Body) 647(Panel) 6 90 4 0 57 3 545(Hook-location) 575(Body) 647(Panel) Service Spaces (unit: ) Water pipe joint Drain pipe joint Water pipe joint Drain pipe joint >000 >000 >300 >300 >000 >000 Ceiling 300~800 Outlet Inlet 600 (ceiling hole) Outlet Panel Ceiling 300~800 Outlet Inlet 600 (ceiling hole) Outlet Panel Ground -pipe compact 4-way cassette 4-pipe compact 4-way cassette 35

Height of the front panel H () 4-way cassette 45 H Wall mounted - S type Dimensions (unit: ) Compact 4-way cassette 50 75 5 C Size MKG-V50-B MKG-V300-B MKG-V400-B MKG-V500-B MKG-V600-B A B 6 8 60 8 30 A B 73 95 89 07 4 D C 90 35 D 663 83 Wall mounted - C type Dimensions (unit: ) 4 90 48 90 0 60 Size A MKG-V50 MKG-V300 MKG-V400 95 MKG-V500 MKG-V600 070 C A D 69 84 B C 90 75 35 885 66 65 D 670 85 Duct Dimensions (unit: ) F A B (Air return) 4 80 4 80 4 80 6 4 80 Drain port Terminal box 6 4-0 6 hanger slots C D E 56 70 50 470 5 58 8 40 -pipe duct water inlet Water outlet Air release valve 0 58 8 Drain port 40 ZG3/4 Cold water inlet RC3/4 4-pipe duct Hot water outlet RC3/4 Cold water outlet RC3/4 Air release valve 0 Hot water inlet RC3/4 36

37 50 74 8 40 03 345 59 0 9 A A 43 B 0 46 05 07 D C 50 55 0 59 59 Exposed type 800 584 500 56 000 784 700 76 00 984 900 96 500 84 00 6 A() B() C() D() MKH4-V50/50 MKH5-V50/50 MKH4-V300/400 MKH5-V300/400 MKH4-V450/500 MKH5-V450/500 MKH4-V600~900 MKH5-V600~900 MKH3-V50/50 550 56 500 53 MKH3-V300/400 750 76 700 73 MKH3-V450/500 950 96 900 93 MKH3-V600~900 50 6 00 3 A() B() C() D() 545 545 6 345 03 9 78 A A 05 9 46 D B A C MKF3 MKH3 Dimensions (unit: ) Concealed type Ceiling & Floor (continued: duct units dimensions) Size 00CFM 300CFM 400CFM 500CFM 600CFM 800CFM 000CFM 00CFM A 545 645 745 745 965 65 370 660 B 485 585 685 685 905 05 30 600 D 485 585 685 685 905 05 30 600 E 74 84 94 94 6 46 566 856 F 583 683 783 783 003 303 408 698 C 53 63 73 73 933 33 338 68

Control Devices Wireless remote controllers Appearance Function Descriptions Applicable FCUs R05/BGE LCD display screen Mode control Fan speeds control Time setting / Temp. setting / Swing setting 4-way Cassette (standard) Compact 4-way cassette (standard) Wall mounted (standard) Wired controllers Appearance Function Descriptions Applicable FCUs LCD display screen KJRP-86A-E Mode control Fan speeds control Timer setting / Temp. setting Duct without electric heater (optional) Mechanical thermostat KJR-8B/E KJR-B/D Mode control Fan speeds control Temp. setting LCD display screen Mode control / Fan speeds control Electric heater control Temp. setting Duct without electric heater (optional) Duct with electric heater (optional) KJR-5B/E KJR-9B/E KJR-B/E Centralized controllers LCD display screen Mode control Fan speeds control Temperature display in o F or o C LCD display screen Mode control Fan speeds control Temp. setting Swing function Mode control Fan speeds control Temp. setting Floor standing / Ceiling & floor (optional) Cassette / Wall-mounted (optional) Cassette / Wall-mounted (optional) Appearance Function Descriptions Applicable FCUs Large LCD display screen CCM03 Max. of 64 FCUs can be controlled by a CCM03 Mode control / fan speed control Time setting / temp. setting / swing setting CCM09 Weekly schedule function Basic functions are same as CCM03 All FCUs (Compact 4-way cassette FCUs need adding NIM0 module, non-pcb FCUs need adding PC board control kit) CCM30 Touch-style keys Basic functions are same as CCM03 38

Accessories PC Board Control Kit for FCU Available for all non-pcb FCUs. Flexible installation, it can be attached to the unit, mounted on a wall or hung under a ceiling. External installation making maintenance more convenient. Functions: Three fan speeds control, Water pump control, Long-distance ON/OFF control, ALARM function, Electric heater control. Operating status can be displayed by wired controller lamp indicator. Centralized control function. BMS control function through Modbus protocol. PC Board Control Kit Centralized control X,Y,E X,Y,E X,Y,E X,Y,E Centralized controller BMS control function through Modbus protocol P,Q,E P,Q,E P,Q,E P,Q,E QE P R+ R- E RS3 Pin hole Modbus Modbus BMS USB port 39

Applicable appliance CE-FCUKZ-03 -pipe FCUs CE-FCUKZ-04 4-pipe FCUs Power supply V-Ph-Hz 0~40--50/60 Operation range Room temp. o C 7-30 Temp. controlling precision Net dimension Packing size Inlet water temp. W H D W H D o C o C 3-75 ± 96 66 40 5 6 Net weight.4.5 Valve Kit Working Voltage: AC30±0%, 50/60Hz(4V can be customized). Power Consumption: 4W Nominal Pressure:.6MPa. Applied Medium: Cold or hot water, 50% glycol water liquor. Medium Temperature: -5 C(DDSTF-0), -0- C(DDSTF-04/05). Environment Temperature: -5-50 C(DDSTF-0), 0-50 C(DDSTF-04/05). DDSTF-0 DDSTF-04 DDSTF-05 DN() Inner Screw Thead Applicable Appliance DDSTF-0 0 3/4 -pipe cassette/duct/floor standing, 4-pipe duct DDSTF-04 5 / 4-pipe cassette (for hot water) DDSTF-05 0 3/4 -pipe ceiling & floor, 4-pipe cassette (for cold water) 40

Application of Central Control & BMS Control PCB Kit PCB Kit PCB Kit M-interface M-net LAN PC Access Laptop Access Pad Access Cloud Servers 4th generation monitoring system PC Data converter CCM5 Internet Router BMS BACnet Modubus LonWorks BMS gateway PC in LAN TCP/IP network Note: if cassette type units connect to centralized controller or BMS, PCB of the unit should be customized. 4

Selection Software Features Select by entering air and water conditions as well as fan speed. Easy to operate interface and visual display. Powerful project management function. Main Interface Function Area Management Area Selection Area Add/Delete Unit 4

Selection Interface Report Data Interface 43

44

703-C70 Coercial Air Conditioner Division Midea Group Add.: Midea Headquarters Building, 6 Midea Avenue, Shunde, Foshan, Guangdong, China Midea CAC After-service Application Midea CAC News Application Postal code: 583 Tel: +86-757-6338346 Fax: +86-757-39005 cac.midea.com global.midea.com Note: Product specifications change from time to time as product improvements and ios Version Android Version ios Version developments are released and may vary from those in this document.