Bdl60u Fluorescent Emergency Ballast

Similar documents
LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400

Ni - Cd THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

GTD20A Installation Instructions BRANCH CIRCUIT TRANSFER SWITCH/LIGHTING CONTROL DEVICE

SERVICE BY QUALIFIED PERSONNEL ONLY

Emergency Lighting. Product Guide LED. The right source for the. right light

BACKUP BATTERY INSTALLATION INSTRUCTIONS

CDL8 LED Architectural

ESRB and ESRN Installation & Safety Instructions

INSTALLATION INSTRUCTIONS - PS1055LCP & PS1555LCP LED EMERGENCY DRIVER PS1055LCP & PS1555LCP

INSTALLATION INSTRUCTIONS - POWER SENTRY CONTROL POWER SENTRY CONTROL UNIT PSBCEB2 INSTALLATION INSTRUCTIONS

ILB-CP TBTS B MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED Patented. See iotaengineering.com/patents for more details

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

HIGH BAY APPLICATIONS

SECTION INTERIOR LIGHTING

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

NYC Approved Product Series

LED RETROFIT CONVERSION KITS

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

LED RETROFIT CONVERSION KITS

ILB-CP TBTS A MOUNTING DESIGN EMERGENCY LIGHTING EQUIPMENT FOR LED

WINDSOR FOREST HIGH SCHOOL HVAC REPLACEMENT ADDENDUM #2 SAVANNAH CHATHAM COUNTY PUBLIC SCHOOL SYSTEM FEBRUARY 18, 2016

LED RETROFIT SOLUTIONS

INSTALLATION INSTRUCTIONS

LED Emergency Battery Backup Installation Instructions Ordering Code: EB23UQ

Compatible with most electronic AC ballasts Maintenance-free, long-life, high temperature Ni-Cad battery Durable, heavy duty steel housing 5-year

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

SECTION INTERIOR AND EXTERIOR LIGHTING FIXTURES

MANUFACTURED IN THE UK

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

SECTION INTERIOR LIGHTING

1 General Description

IOTA Exit Signs. IOTA Emergency Fixtures

Ni - Cd THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

LED Emergency Battery Backup

CL001 >400 Watt lamp basecase, up to 600 Watt replacement fixture $95.00 Fixture

Nightfall. led emergency egress lighting

Related Sections: TBD. Effective Date: January 1, 2016

SETION EMERGENCY LIGHTING NATIONAL FIRE PROTECTION ASSOCIATION (NEPA) (2006) Life Safety Code, 2006 Edition

SECTION INTERIOR LIGHTING

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

TROFFER RETROFIT KIT (TRK)

MODEL RLY-DIM-D INSTALLATION INSTRUCTIONS

MaxLite LED VAPOR TIGHT LINEAR FIXTURES

BAS SFP22 Edge-lit LED Panel

Selecting And Applying Emergency Lighting Systems

WPLED 26W INSTALLATION INSTRUCTIONS

THE HIGH STAIRWELL AND PASSAGEWAY FIXTURE PERFORMANCE KEY FEATURES INCLUDE:

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

FPLHB - Fidelux Premier Linear Highbay

Honeywell Durafit LED Retrofit Kit

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

Dioluce Products Installation Instructions

1 x4 Dimmable LED RetroFits

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Lighting Solutions. from a Leader in Light Source Technology

Business Customer Information. Account Number (9 digits) Account Holder Name Phone (As shown on your utility bill) Service Street Address

Emergency TLED Lighting Retrofit 101. December 6 th 2017

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

TSLED STAIRWELL INSTALLATION INSTRUCTIONS

Catalog Number. Notes

LED Lighting: Technology Selection and System Commissioning Course Number: CXENERGY1519

DISTRIBUTOR SELECT COLLECTION. EMERGI-LITE Full range of emergency lighting solutions

MaxLite LED High Bay Fixtures

VENTILATION FAN. MFG Model : VFB80HLED2/VFB080C4L2 /VFB080C4LED2/ VFB100HLED2/VFB100C4LED1 READ AND SAVE THESE INSTRUCTIONS

PSO Business Rebates Retrofit Lighting Technical Requirements

Installation Instructions

TRUELITE LED TUBE.

LED retrofits! 4 T8 Specification Guide. Retrofit your existing Fluorescent Lights in Seconds No Electrician Needed! Pure Bright

2018 Instant Lighting Rebates Product Catalog

Application Note. Using XPoint Wireless Devices with Emergency Lighting. 1 of 16

Venture Lighting s Line of LED Solutions. Professional Grade LED from The Leader in HID

Applications. Standard Materials

Lumination LED Luminaires

Explosion Proof Emergency Fluorescent Light Combination - Dimmable Ballast - C1D1-2 T8 lamps - 4'

UNIFIED FACILITIES GUIDE SPECIFICATIONS

2. Lighting fixtures mounted on exterior building surfaces.

S5JB Quick Setup Guide. Refer to the instructions on the following pages for complete details on the steps outlined below.

LED IMPORTANT SAFETY INSTRUCTIONS

48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2

light ACL9 ANATOMY PERIMETER FOCUSED INSTALLATION SLEEK & STRONG

BATH FAN / LED LIGHT READ AND SAVE THESE INSTRUCTIONS MODEL GBR100LED-DECOR TABLE OF CONTENTS. Package Contents 2. General Safety Information 3

Relay Panel and Relay Panel Module Wiring and installation manual Light is OSRAM

RAZOR RZR SERIES DIE CAST ALUMINUM LED EXIT SIGNS INSTALLATION AND OPERATING INSTRUCTIONS IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

The New Lux-Ray LED Emergency Lighting

Lighting Solutions from a Leader in Light Source Technology

4' 2 Lamp Fluorescent Light Fixture - Emergency Battery Backup - T8 Bulbs - Multi-voltage - CID2

Spectron LSN (Life Safety Network) Suggested Specifications

Project Name. Date. Cat. Number. Type

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

HEP Tech Co., Ltd. Company Profile

Selecting & Applying Emergency Lighting Systems

REVISIONS Summary of Change. 6/1/12 All Replaced entire document with new revision

PRODUCT DATA SHEET LIGHTING PRODUCTS

SECTION EXTERIOR LIGHTING

Exit/Emergency Lighting Guide

Transcription:

A Division Of Philips Electronics North America Corporation One- or two-lamp emergency; Universal input voltage: 120 through 277 V, 50 or 60 Hz; Replaces B60U Bdl60u Fluorescent Emergency Ballast Product Summary UL LISTED Factory or Field Installation (Indoor and Damp) Illumination Time 90 Minutes (Standard) 120 Minutes (One 32 W T8) Initial Light Output 300-700 Lumens Full Warranty 3 Years (NOT pro-rata) Universal Input Voltage 120 Through 277 V, 50 or 60 Hz Input Current 60 ma Input Power Rating 5.0 Watts Test Switch Double Pole Battery High-Temperature, Maintenance-Free Nickel-Cadmium Battery 7- to 10-Year Life Expectancy Battery Charging Current 280 ma Recharge Time 24 Hours Charging Indicator Light LED Temperature Rating (Ambient) 0 C to +50 C (32 F to 122 F) Dimensions 9.4 x 2.4 x 1.5 (238 mm x 60 mm x 38 mm) Mounting Center 8.9 (226 mm) Weight 2.5 lbs. (1.13 kg) APPLICATION The BDL60U Universal Input fluorescent emergency ballast works in conjunction with an ballast to convert fluorescent fixtures into emergency lighting. The emergency ballast handles a wide range of input voltages and frequencies and consists of a high-temperature nickel-cadmium battery, charger and electronic circuitry in one compact red case. The BDL60U can be used with most 13-215 W (2-8 ) T8, T10 or T12 fluorescent lamps without integral starters, including U-shaped, HO, VHO, circline and energy-saving, and (4-pin) long compacts (see Table 1). It is also compatible with most 120 through 277 V (50 or 60 Hz) one-, two-, three- and four-lamp electronic, standard, energysaving and dimming ballasts. If used in an emergency-only fixture, no ballast is necessary. The BDL60U is suitable for indoor and damp locations and for sealed & gasketed fixtures, including fixtures rated for wet locations. It is not suitable for air handling heated air outlets or wet or hazardous locations. For information about specific lamp and ballast compatibility, please call the factory. Recommended applications include: international line voltages from 120 through 277 V (50 or 60 Hz); drilling rigs where generators are the primary source of power; and other applications requiring higher tolerance of line voltage variation or harmonic distortion. OPERATION When power fails, the BDL60U immediately switches to the emergency mode, operating either one or two lamps at a reduced lumen output for a minimum of 90 minutes. Two-hour duration may be selected with one 32 W T8 fluorescent lamp. When power is restored, the BDL60U automatically returns to the charging mode. INSTALLATION The BDL60U does not affect normal fixture operation and may be used with either a switched or unswitched fixture. If a switched fixture is used, an unswitched hot lead must be connected to the emergency ballast. The emergency ballast must be fed from the same branch circuit as the ballast. The emergency ballast may be installed inside, on top of or remote from the fixture. The BDL60U may be remotely installed up to half the distance the ballast manufacturer recommends remoting the ballast from the lamp or up to 50 feet, whichever is less. Installation is not recommended with fixtures where the ambient temperature may fall below 0 C. UL and CODE PLIANCE The BDL60U has been tested by Underwriters Laboratories in accordance with the standards set forth in UL 924, "Emergency Lighting and Power Equipment, and is UL Listed for factory or field installation. Emergency illumination time exceeds the National Electrical Code (NEC), Life Safety Code (NFPA LSC) and UL 90-minute requirements. Emergency ballasts can be modified to accomodate longer run times. Specifiers Reference Project Type Model No. Comments L2000025 04/21/08 The Bodine Company P.O. Box 460 Collierville, TN USA 38027-0460 Sales 800-223-5728 FAX 901-853-5009 Tech. Support 888-263-4638 www.bodine.com

BDL60U Fluorescent Emergency Ballast One- or two-lamp emergency; Universal input voltage: 120 through 277 V, 50 or 60 Hz; Replaces B60U ILLUMINATION Depending on the number (one or two), wattage and type of lamps selected, the BDL60U produces 300 to 700 lumens initial emergency light output (see Table 2). If two-lamp operation is selected, light output is evenly divided between the lamps for better distribution of emergency illumination. SPECIFICATION Emergency lighting shall be provided by using a standard fluorescent fixture equipped with a Bodine BDL60U Universal Input fluorescent emergency ballast. This emergency ballast shall consist of a high-temperature, maintenance-free nickel-cadmium battery, charger and electronic circuitry contained in one 9 3/8 x 2 3/8 x 1 1/2 red metal case. A solid-state charging indicator light to monitor the charger and battery, a double-pole test switch and installation hardware shall be provided. The emergency ballast shall be capable of operating [one or two] fluorescent lamp(s) at lumens (see Table 2) initial light output in the emergency mode for a minimum of 90 minutes or one 32 W T8 fluorescent lamp at reduced illumination in the emergency mode for a minimum of 120 minutes. It shall be suitable for indoor and damp locations and for sealed & gasketed fixtures, including fixtures rated for wet locations. The BDL60U shall have 5 Watts of input power and a 14.4 Watt-hour battery capacity and shall comply with emergency standards set forth by the current NEC. The emergency ballast shall be UL Listed for installation inside, on top of or remote from the fixture and shall be warranted for a full three years from date of purchase. WARRANTY Model BDL60U is warranted for three (3) full years from date of purchase. This warranty covers only properly installed Bodine emergency ballasts used under normal conditions. For the warranty period, Bodine will, at its option, repair or replace without charge a defective emergency ballast, provided it is returned to the factory transportation prepaid and our inspection determines it to be defective under terms of the warranty. Repair or replacement, as stated above, shall constitute the purchaser s exclusive warranty, which does not extend to transportation, installation, labor or any other charges; nor does it apply to any equipment of another manufacturer used in conjunction with the emergency ballast. LAMP DIAMETER 1", 1¼", 1½" T8, T9, T10, T12 Table 1 - Lamp Compatibility BASE Single or Bipin WATTAGE (Length) 17-40 W (2'-4') NO. of LAMPS () 40-215 W (5'-8') 1 Long Compact 4-pin (2G11) 18-40 W 1 Table 2 - Initial Lumen Output LAMP 1 2 LUMENS 1 Lamp 2 Lamps FO32, FBO31 T8 575 625 FO25, FB024 T8 450 575 FO17, FB016 T8 375 550 FO96 T8 700 F40T12, F40/U 350 375 F40T12/ES (34 W) 350 375 F96T12 HO, VHO 575 PL-L 40W, F40/30BX, Dulux L 40 W 625 PL-L 36W, F39/36BX, Dulux L 36 W 525 PL-L 24W, F27/24BX/RS, Dulux L 24 W 375 475 PL-L 18W, F18BX, Dulux L 24 W 375 F382D/4P 625 F282D/4P 450 F212D/4P 375 500 F162D/4P 300 375 L2000025 04/21/08 The Bodine Company P.O. Box 460 Collierville, TN USA 38027-0460 Sales 800-223-5728 FAX 901-853-5009 Tech. Support 888-263-4638 www.bodine.com

bodine BDL Series Fluorescent Emergency Ballasts 2007 The Bodine Company The BDL Series Ballasts are Rated for Damp Location, Vapor-Tight Applications L0000026

BDL Series Fluorescent Backup Ballasts When Conditions Are Less Than Perfect... Damp Locations: Partially protected exterior locations under canopies, marquees, roofed open porches and the like, as well as interior locations subject to moderate degrees of moisture such as some basements, barns or cold storage houses. [1] Source: [1] Rea, Mark S. Lighting Handbook-Reference & Application. Illuminating Engineering Society of North America: 1993. For more information on the codes applicable to damp locations, see the National Electrical Code, Chapter 14, Codes and Standards. Emergency lighting equipment is included in building designs to provide backup lighting along the path of egress during loss of power so that occupants can exit the building quickly and safely. Because the path of egress often continues outside of a building to a partially protected public way and may include interior areas exposed to moisture, some local codes or building plans require emergency lighting with more than an indoor-dry location rating. Recommended uses include warehouses, covered walkways, parking garages, aircraft hangars, exterior stairways and any other location with damp rated or vapor-type fixtures. 2 Sales 800.223.5728 Fax 901.853.5009 www.bodine.com

bodine Application Bodine damp location emergency ballasts convert partially protected exterior and interior fluorescent fixtures subject to moderate degrees of moisture into unobtrusive emergency lighting fixtures. These emergency ballasts are UL LISTED for damp locations where the ambient temperature for the emergency ballast is 0 C minimum, +50 C maximum. Code Compliance Damp location models have been tested by Underwriters Laboratories in accordance with the standards set forth in UL 924, Emergency Lighting and Power Equipment - Supplement C, and are UL LISTED for installation inside of or on top of the fixture. Emergency illumination exceeds the 90-minute requirement of the National Fire Protection Association s Life Safety Code (NFPA-LSC), the National Electrical Code (NEC) and UL. Damp location models are compatible with a variety of fluorescent lamps, including U- shaped, HO, VHO, circline and energy-saving tubular fluorescent lamps, as well as with 2-pin and 4-pin compact fluorescent lamps. Damp location ballasts are compatible with most electronic, standard, energy-saving and dimming ballasts. Models for one- or twolamp operation are available. For questions concerning specific lamp/ballast compatibility, please call Tech Support at 888-263-4638. Select Bodine damp location models are UL LISTED for use in sealed and gasketed fixtures. Damp location models are compatible with a variety of fluorescent lamps, including U-shaped, HO, VHO, circline and energy-saving tubular fluorescent lamps, as well as with 2-pin and 4-pin compact fluorescent lamps. Note: See Damp Location Product Summary on the back page for individual product details. Installation Damp location models do not affect normal fixture operation and may be used in either a switched or unswitched fixture. In switched fixtures, an unswitched lead must be connected to the emergency ballast ahead of the wall switch. The emergency ballast may be remotely installed up to one half the distance the ballast manufacturer recommends remoting the ballast from the lamp or up to 50 feet, whichever is less. Battery All damp location models contain hightemperature nickel-cadmium batteries. These batteries are maintenance free, can be safely installed inside the ballast channel and have a life expectancy of 7 to 10 years. Note: If a damp location ballast is used in an emergency-only fixture, no ballast is necessary. 236 Mt. Pleasant Rd. Collierville, TN 38017 3

BDL Series Meeting Global Demands for Superior Technology c Model # Lumen Output # Lamps Operated Type of Lamps Operated Full Warranty BDL500* (B50) 1100-1400 lm 2 BDL600* (B60) 600-700 lm 2 BDL700 (B70A) 600-700 lm 1 BDL900 (B90) 500-600 lm 1 BDL94C (B94C) 300-750 lm 2 17 W - 215 W (2-8 ) T8, T10 or T12 4-Pin Long Compact 17 W - 215 W (2-8 ) T8, T10 or T12 4-Pin Long Compact 17 W - 215 W (2-8 ) T8, T10 or T12 4-Pin Long Compact 17 W - 40 W (2-4 ) T8, T10 or T12 4-Pin Long Compact 6 W - 42 W (4-Pin) Twin, Quad or Triple Twin-Tube 5 Years 3 Years 3 Years 1 Year 2 Years 10 W - 26 W BDL426 (B426) 450-950 lm 2 2 Years (2-Pin) Twin, Quad or Triple Twin-Tube BDL463 (B463) 300-650 lm 1 BDL413 (B413) 200-625 lm 1 10 W - 26 W (2-Pin) Quad or Triple Twin-Tube 5 W - 13 W (2-Pin) Twin or Quad Tube 2 Years 2 Years All models are 120/277 V dual voltage input and suitable for damp locations where the ambient temperature for the emergency ballast is 0 C minimum, +50 C maximum. Damp location models are not recommended for heated air outlets or hazardous location fixtures. For alternate configurations and UL Component Recognized models for hazardous location fixtures, please contact Bodine. For complete technical specifications, please refer to the appropriate dry location counterpart specification sheet. * The BDL500 and BDL600 are UL LISTED for use in sealed and gasketed fixtures. Operation When power fails, the damp location emergency ballast automatically switches to emergency mode, keeping either one or two lamps illuminated at a reduced lumen output for a minimum of 90 minutes. If two-lamp operation is selected, lumen output is evenly distributed between the lamps. When power is restored, the damp location emergency ballast returns to the charging mode. About The Manufacturer Since 1962, The Bodine Company, Inc., has responded to advancements in lamp/ballast technologies by developing a complete line of tubular and compact fluorescent emergency ballasts for a variety of emergency lighting applications. Products are sold through a nationwide network of manufacturers representatives and electrical distributors for field retrofit or directly to lighting fixture manufacturers for factory installation only. The Bodine Company is a member of the Illuminating Engineering Society of North America (IESNA) and the National Electrical Manufacturers Association (NEMA). bodine

bodine BDL60U UNIVERSAL INPUT FLUORESCENT Installation Instructions! IMPORTANT SAFEGUARDS! WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED, INCLUDING THE FOLLOWING: READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. To prevent high voltage from being present on red & yellow output leads prior to installation, inverter connector must be open. Do not join inverter connector until installation is complete and power is supplied to the emergency ballast. 2. This product is for use with two 17-40 W (2' - 4') T8, T10 or T12 fluorescent lamps; one 25-215 W (2' - 8') T8, T10 or T12 fluorescent lamp; two 13-26 W (4-pin) compact fluorescent lamps without integral starters; or one 18-42 W (4-pin) compact fluorescent lamp without integral starter. 3. Make sure all connections are in accordance with the National Electrical Code and any local regulations. 4. To reduce the risk of electric shock, disconnect both normal and emergency power supplies and inverter connector of the emergency ballast before servicing. 5. This emergency ballast is for factory or field installation in either the ballast channel or on top of the fixture. 6. This product is suitable for damp locations where the ambient temperature is 0 C minimum, +50 C maximum. Product is also suitable for installation in sealed and gasketed fixtures. Product is not suitable for heated air outlets and wet or hazardous locations. 7. An unswitched power source is required (120 through 277 V, 50/60 Hz). 8. Do not install near gas or electric heaters. 9. Do not attempt to service the battery. A sealed, no-maintenance battery is used that is not field replaceable. Contact the manufacturer for information on service. 10. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition. 11. Do not use this product for other than intended use. 12. Servicing should be performed by qualified service personnel. SAVE THESE INSTRUCTIONS Ni-Cd THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY. 04/25/05 The Bodine Company, Inc. 236 Mt. Pleasant Rd. Collierville, TN 38017-2752 Tech Support 888-263-4638 Fax 901-854-1630 www.bodine.com 76000201

WARNING: TO PREVENT HIGH VOLTAGE FROM BEING PRESENT ON & OUTPUT LEADS PRIOR TO INSTALLATION, MUST BE OPEN. DO NOT JOIN UNTIL INSTALLATION IS PLETE AND POWER IS SUPPLIED TO THE. NOTE: INSTALLATION Make sure that the necessary branch circuit wiring is available. An unswitched source of power is required. The emergency ballast must be fed from the same branch circuit as the ballast. STEP #1 INSTALLING THE > Disconnect power from the fixture. Remove the ballast channel cover and install the emergency * ballast either in the ballast channel or on top of the fixture. > Depending on the type of fixture in use, install emergency ballast using one of the methods illustrated below. Inside Ballast Channel Inside Strip Fixture On Top of Fixture * For installation on top of the fixture, wire bundle covers (RMC-60) may be required by state or local codes. These covers are available from the manufacturer as an accessory kit and must be ordered separately. Call your local distributor or the factory for complete information. STEP #2 INSTALLING THE TEST SWITCH > Refer to the illustrations above and install the test switch through the ballast channel cover of a troffer or through the side of a strip fixture. > Drill a 1/2" hole and install the switch as shown. > Refer to the diagrams below and wire the test switch so that it removes power from both the emergency ballast and the Throw to Test Fixture Toggle Switch Hex Nut Hex Nut Test Switch Leads Leads ballast at the same time. UNSWITCHED FIXTURE SWITCHED FIXTURE TEST SWITCH TEST SWITCH HOT HOT WALL SWITCH

INSTALLATION STEP #3 INSTALLING THE > Install the as shown in the illustration below so that it will be visible after the fixture is installed. TROFFER STYLE FIXTURE STRIP STYLE FIXTURE Emergency Ballast Ballast Channel Cover 7/8" Punch Plastic Tubing (please cut to necessary length) Charging Indicator Light Fixture Lens Leads to Charging Indicator Light 7/8" Bushing Inserted into Ballast Channel Cover 1/2" White Bushing to Hold Charging Indicator Light Charging Indicator Light 1/2" White Bushing 1/2" Punch Fixture Violet (+) Brown ( ) 5/8" Black Bushing Charging Indicator Light 1/2" White Bushing Fixture Violet (+) Brown ( ) 5/8" Black Bushing NOTE: After installing the charging indicator light and test switch, mark each with the appropriate label. STEP #4 WIRING THE > Determine the type of ballast installed in the fixture. > Select the appropriate wiring diagram on back to connect the emergency ballast to the ballast and lamp(s). Make sure all connections are in accordance with the National Electrical Code and any local regulations. > After installation is complete, supply power to the emergency ballast and join the inverter connector. > At this point, power should be connected to both the ballast and the emergency ballast and the Charging Indicator Light should illuminate indicating the battery is charging. > A short-term discharge test may be conducted after the emergency ballast has been charging for one hour. Charge for 24 hours before conducting a long-term discharge test. Refer to OPERATION. > In a readily visible location, attach the label "CAUTION - This Unit Has More Than One Power Connection Point. To Reduce The Risk Of Electric Shock, Disconnect Both The Branch Circuit-Breakers Or Fuses And Emergency Power Supplies Before Servicing." When power is applied, the charging indicator light is illuminated, indicating that the battery is being charged. When power fails, the emergency ballast automatically switches to emergency power (internal battery), operating either one or two lamps at reduced illumination for a minimum of 90 minutes. This emergency ballast also operates one 32 W T8 fluorescent lamp in emergency mode for a minimum of 120 minutes. OPERATION MAINTENANCE Although no routine maintenance is required to keep the emergency ballast functional, it should be checked periodically to ensure that it is working. The following schedule is recommended: 1. Visually inspect the charging indicator light monthly. It should be illuminated. 2. Test the emergency operation of the fixture at 30-day intervals for a minimum of 30 seconds. Either one or two lamps should operate at reduced illumination. 3. Conduct a 90-minute discharge test once a year. Either one or two lamps should operate at reduced illumination for at least 90 minutes.! REFER ANY SERVICING INDICATED BY THESE CHECKS TO QUALIFIED PERSONNEL! 04/25/05 76000201

AND MUST BE FED FROM THE SAME BRANCH CIRCUIT TYPICAL SCHEMATICS ONLY. MAY BE USED WITH OTHER S. CONSULT THE FTORY FOR OTHER WIRING DIAGRAMS. WIRING DIAGRAMS FOR 1-LAMP OPERATION FIG 36a-UV TWO (2) LAMP INSTANT START FIG 3a-UV TWO (2) LAMP RAPID START /WHT VIOLET TO UNSWITCHED /WHT VIOLET TO UNSWITCHED () () FIG 7a-UV THREE (3) LAMP INSTANT START FIG 15a-UV THREE (3) LAMP RAPID START or YELL /WHT VIOLET TO UNSWITCHED /WHT /WHT /WHT VIOLET TO UNSWITCHED LAMP 3 () LAMP 3 () FIG 14a-UV FOUR (4) LAMP INSTANT START FIG 51a-UV FOUR (4) LAMP RAPID START /WHT VIOLET TO UNSWITCHED /WHT /WHT /WHT VIOLET TO UNSWITCHED LAMP 3 LAMP 3 LAMP 4 () LAMP 4 WIRING DIAGRAMS for 2-LAMP OPERATION (2-4, 17-40 W lamps only) FIG 36b-UV TWO (2) LAMP INSTANT START FIG 3b-UV TWO (2) LAMP RAPID START /WHT VIOLET TO UNSWITCHED HOT /WHT VIOLET TO UNSWITCHED HOT FIG 7b-UV THREE (3) LAMP INSTANT START FIG 14b-UV FOUR (4) LAMP INSTANT START or YELL /WHT VIOLET TO UNSWITCHED /WHT VIOLET TO UNSWITCHED () LAMP 3 () LAMP 3 () LAMP 4 () WIRING DIAGRAMS for -ONLY fixtures FIG 1a-UV ONE (1) 17-215 W LAMP WITHOUT FIG 1b-UV TWO (2) 17-40 W LAMPS WITHOUT CAP CAP /WHT VIOLET TO UNSWITCHED CAP CAP /WHT VIOLET TO UNSWITCHED LAMP LAMP LAMP