Air Cooled Oil Coolers

Similar documents
QUALITY PRODUCTS, INC. OIL-TO-AIR HEAT EXCHANGERS

OK, OKA, OKAF; ELD; ELDM; ELH; OKC; SC; SCA; SCAF; OK-LN; OKA-LN; OKAF-LN.

Wilo IL Vertical Split-Coupled Inline Pumps

The Quincy QMB and QMT: A new approach to the modular advantage

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

Tel: Fax: Website:

Air Cooler Industry OK-ELC 0-7

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

AIR SENTRY DESICCANT BREATHERS

LIST Price - $2, Model Number: MFD-1-27-GX-X-B-14. *Quick Delivery of Units are Subject to Prior Sales

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Oil-Less Rotary Screw Compressors Variable Speed. Engineered to Save

VUD. Vac-U-Dry Vacuum Dehydrators. hyprofiltration.com/vud

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

L07 - L22. Oil Injected Rotary Screw Compressors. Intelligent Air Technology

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

TECHNICAL, OPERATING & INSTALLATION MANUAL TC 15, 33, 52 AIR COOLED PACKAGED WATER CHILLERS

1600 Series Rotating Suction Screen

Specially Designed Waste Water & Sewage Pumps

MATERIALS FILTERS PRESSURE VALUE TESTS CARRIED OUT ON FILTERING ELEMENTS

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

Rotary screw compressors

ACORE Filtration Co.,Ltd provides engineering,

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Portable Purification zf04 Systems Models PVS 185, 600, 1200, 1800, 2700

Precise Temperature Control; Compact Footprint

Phoenix C4XE - Membrane Based Portable Lube and Hydraulic Oil Purifier Cart For use in Hazardous Duty Locations.

Operations and Maintenance Manual

K4RB(X) 4 Submersible, Recessed Impeller (Class 1, Div. 1, Groups C & D Hazardous Location)

Rotary Screw Vacuum Packages

Lubricated Rotary Screw Air Compressors

CLOSED COUPLED CENTRIFUGAL PUMPS

KRAL Screw Pumps. L Series.

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

VUD. Vac-U-Dry Vacuum Dehydrators. hyprofiltration.com/vud

Fuji Electronic VFC 084P-5T

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

SPECIFICATIONS MODEL E859C MINI DEHYDRATOR

MACH N-407 Heat Pump Air-Cooled Chiller

Rotary screw compressors

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

FLANGE-MOUNT CENTRIFUGAL PUMPS

30GT FLOTRONIC AIR-COOLED CHILLERS

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Call us today! (800)

TYPICAL CPA SPECIFICATIONS

TYPE VSM/VSMS VERTICAL SPACE MISER PUMPS

Rotary screw compressors. kw 2, ,5 bar 10 BRIO

INSTALLATION AND SERVICE INSTRUCTIONS. Tuthill atlantic fluidics OSR-5, 10,15 & 20. Oil sealed liquid ring vacuum pump

LS-100 BEGIN SAVING MONEY FROM DAY 1. Lubricated Rotary Screw Air Compressors 25 to 40 hp

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

A new concept at refueling CNG stations

CPF PRODUCT DESCRIPTION

New Product Introductions 2011

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Microchannel REMOTE AIR COOLED CONDENSER. Technical Bulletin: MXCC_004_ Products that provide lasting solutions.

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Fans: Features and Analysis

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

NEW INTELLIGENT AIR TECHNOLOGY

Energy-Saving Industrial Water Chillers

Vacuum Oil Purifier (VOP) (5 Pages. June 2017)

in/out connections outer Ø 25 bar (363 psi) 200 kg/h SS '000 (2.12 HP) 300 kg/h CU (661 lb/h) (3.18 HP) 300 kg/h SS (661 lb)

Pumps SELECTION OF A PUMP

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

CPVS PRODUCT DESCRIPTION

Phoenix C 1 GPM - Membrane Based Portable Lube and Hydraulic Oil Purifier Cart

VertiCool Aurora Engineering Guide

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

Temptek Auxiliary Equipment

CPC PRODUCT DESCRIPTION

Water-Cooled Self-Contained Units

Product Catalogue CG-PRC002E-EN. CGAD Liquid Chillers Air-Cooled Scroll Compressor 20 to 150 Tons. July Models: 50 / 60 Hz

With the world-renowned SIGMA PROFILE

our contribution for Sealless Magnetic Coupled, Heavy Duty Side-Channel Pumps environmental protection Type SCM PN40

Call us today! (800)

Stokes Microvac Model 212J

CC150 General Production Hose Crimper

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 PROVEN PERFORMANCE GENERAL FEATURING

VERTICOOL TECHNICAL DATA MANUAL. Vertical Air/Water Cooled 3-25 Tons

MLC Air Cooled Chillers MLC-FC Free Cooling Chillers MLC-AD Adiabatic Chillers

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Rotary screw Air compressors. Fixed Speed 5 15HP

K4RH(X) Solids-Handling Pumps

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

Call us today! (800)

KGP(X) Grinder Pumps HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve.

PAJ3. Product Specifications

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

technical guide Water-Cooled Self-Contained Units

CALEFFI. Thermostatic mixing valves with replaceable cartridge for centralized systems. 5230, 5231 series 01080/13 NA ASSE Replaces 01080/11 NA

Evaluation Report 509

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

TYPE LF/LC/LCV END SUCTION PUMPS

Transcription:

FEATURES High efficient plate and fin style heat exchangers Externally mounted heat exchangers for easy maintenance and cleaning SC and OK series feature a modular pump and filter options for a plug and play fluid conditioning system Available with HYDAC MF and LPF series filters Accessories Include: Thermostats (adjustable and fixed), Integrated Thermostatic Bypass Valves, and Bypass Valves Noise levels under 70 dba Air Cooled Oil Coolers SC & OK Series SC Series SC Series The SC Series cooler design uses a large blower wheel which spins slowly to draw air through an oversized cooler. This combination offers excellent cooling capacity with low noise. Up to 16 HP cooling capacity Down to 64 dba noise level Warm air is directed up and away from work area Packaged systems with pump flows ranging from 3.1 GPM to 18.5 GPM Maximum flows (w/o pump) up to 42 GPM OK Series The OK series coolers use an axial fan for moving air across the heat exchanger. Up to 100 HP cooling capacity Packaged systems with pump flows ranging from 8.45 GPM to 47.5 GPM Maximum flows (w/o pump) up to 80 GPM ADVANTAGES The advantages of an off line cooling system are a stable cooling and filtration performance irrespective of variations in flow and duty cycle of the main hydraulic circuit. This allows the cooler to be sized to fit the heat load and not the maximum return flow of the main circuit. A further advantage is that the off-line cooler is completely isolated from surge pressures in the return line that can potentially damage the cooler. Also, maintenance can be performed on the filters without having to shut down the main system. OK Series APPLICATIONS Hydraulic Power Units Elevators Gearboxes Lubrication Systems Presses Machine Centers

Model SC = Basic Cooler SCF = Cooler with filter SCA = Cooler with circulator pump SCAF = Cooler with circulator pump and filter Cooler Size Code OS 1L 1S 2L 2S 3L 3S 4L 4S See heat transfer table found on page 3 to determine proper size. L = 1200 RPM S = 1800 RPM Model Code: SC Series SC 1L 1.5 A 8 MF95 3 B TR1 Motor A = 1 phase 115/230 volt (only available on SC/SCA-0 and 1 models) B = 3 phase 230/460 volt (575 volt optional, contact factory) Pumps Code Pump Displacement GPM (L) 1200 RPM GPM (S) 1800 RPM Heat Exchanger Size (omit) = ---------------------------- No Pump for SC and SCF Models ---------------------------- 10 = 10 ccm/rev 3.1 4.75 OS, 1L, 1S 28 = 28 ccm/rev 8.4 12.75 2L, 2S, 3L, 3S, 4L, 4S 40 = 40 ccm/rev 12 2L, 3L, 4L Filter Type (not applicable for SC and SCA models) Rated GPM* Rated GPM (omit) = No filter / SC and SCA models LPF160 Cartridge 42 MF95 = Spin-on 25 LPF240 Cartridge 63 MF190 = Spin-on 30 MF195 = Spin-on 60 Micron Rating (omit) = No filter / SC and SCA models 3 = 3 microns, Absolute 5 = 5 microns, Absolute 10 = 10 microns, Absolute 20 = 20 microns, Absolute Filter Indicator Code Series Description (omit) = No filter - B = MF Visual C = LPF Electrical (AC/DC) D24 = LPF Visual (lamp) and Electrical (switch) numbers indicate supplu voltage for light D115 = LPF Visual (lamp) and Electrical (switch) LPF Filters only D230 = LPF Visual (lamp) and Electrical (switch) Accessories (omit) = None TR1 = Reservoir Thermostat, adjustable 0 to 200 F IBT-45 = Thermostatic bypass valve, 113 to 131 F IBT-55 = Thermostatic bypass valve, 130 to 150 F IBT-60 = Thermostatic bypass valve, 140 to 158 F IBP-2 = Bypass valve, 29 PSI IBP-3 = Bypass valve, 45 PSI AITR = Inline Thermostat, adjustable 0 to 200 F TS-120 = Inline Thermostat, fixed 120 F only available with TS-140 = Inline Thermostat, fixed 140 F SC & SCF Units TS-160 = Inline Thermostat, fixed 160 F Design and Modification numbers, determined by factory. Latest Version always supplied 2

Cooling Capacities: SC Series Tolerance: +/- 5% 18 16 SC 4S Heat dissipation @ T=4 0 F (HP) 14 12 10 8 6 SC 2S SC 2L SC 3S SC 4L SC 3L 4 SC 1S 2 0 0 5 10 15 20 25 30 35 40 45 Oil flow (GPM) Pressure Drops: SC Series Pressure differential p depending on flow rate Q and the viscosity of the oil. Graph uses oil viscosity of 30mm 2 /s. Tolerance: +/- 5% SC 0S SC 1L 40 SC 3 35 Pressure Drop in PSI @ 30 mm2/s 30 25 20 15 SC 0 SC 2 SC 1 S 4 10 5 0 0 5 10 15 20 25 30 35 40 45 Oil Flow in GPM For oil viscosities other than 30mm 2 /s, in the graph above multiply the p by the factor k for the corrected pressure drop. SSU 46 70 102 150 213 250 315 464 695 mm/sec 10 15 22 32 46 54 68 100 150 Factor K 0.5 0.65 0.77 1 1.3 1.52 1.9 2.8 5.3 Hydraulic Symbols: SC Series SC SCF SCA SCAF 3

SC Specifications / Engineering Data SPECIFICATIONS COOLER MODEL FLUID SPECIFICATIONS MOTOR SPECIFICATIONS Max. Oil Flow Pump Displacement. Noise Without Pump Per Pump Code Level Motor Motor Weight Model Description GPM GPM dba* 1 kw RPM lbs. SC-0, SCF-0 Fan 16 - - 68 0.21 1800 31 SCA-0,SCAF-0 Fan/Pump - Code 10-4.75-70 0.43 1800 51 SC-1L, SCF-1L Fan 32 - - 64 0.30 1200 47 SCA-1L, SCAF-1L Fan/Pump - Code 10-3.1-68 0.43 1200 69 SC-1S, SCF-1S Fan 32 - - 69 0.30 1800 47 SCA-1S, SCAF-1S Fan/Pump - Code 10-4.75-71 0.43 1800 69 SC-2L, SCF-2L Fan 32 - - 66 0.43 1200 71 SCA-2L, SCAF-2L Fan/Pump - Code 28-8.45 Code 40-12 68 1.30 1200 99 SC-2S, SCF-2S Fan 32 - - 76 0.70 1800 71 SCA-2S, SCAF-2S Fan/Pump - Code 28-12.75-77 1.80 1800 99 SC-3L, SCF-3L Fan 42 - - 73 0.70 1200 104 SCA-3L, SCAF-3L Fan/Pump - Code 28-8.45 Code 40-12 73 1.30 1200 148 SC-3S, SCF-3S Fan 42 - - 82 0.91 1800 104 SCA-3S, SCAF-3S Fan/Pump - Code 28-12.75-84 2.20 1800 148 SC-4L, SCF-4L Fan 42 - - 73 0.70 1200 108 SCA-4L, SCAF-4L Fan/Pump - Code 28-8.45 Code 40-12 73 1.30 1200 152 SC-4S, SCF-4S Fan 42 - - 82 0.91 1800 108 SCA-4S, SCAF-4S Fan/Pump - Code 28-12.75-84 2.20 1800 152 *The noise levels are only a guide as acoustic properties depend on the characteristics of the room, connections, viscosity and resonance. 1) 3 Phase Motor GENERAL Construction Housing Welded steel housing, steel filter bracket,steel legs, steel blower wheel Heat Exchanger Aluminum Motors TEFC, IEC Frame B5 Flange Pump Aluminum housing, steel inner pump ring, steel rotor, and steel vanes Mounting Position Horizontal, motor shaft Maximum Pressure W/o Pump 230 PSI (16 BAR) Dynamic 290 PSI (20 BAR) Static With Pump 90 PSI (6 BAR)* Rated Suction Pressure 11.8" Hg (-.4 BAR) to 44 PSI (3 BAR) Fluids Mineral oil to DIN 51524 Part 1 and 2 Contamination Limit Permissible contamination < NAS 12 Max Viscosity W/o Pump 2000 cst With Pump 180 cst Ambient Temperature 50 F (10 C) to 104 F (40 C) Maximum Oil Temperature W/o Pump 266 F (130 C) With Pump 175 F (80 C) Air Flow Direction Pulled across Heat Exchanger *Note: SCA/SCAF units do not include relief valve. Pressure higher than 90 psi (measured at pump outlet) will result in motor overload conditions. 4

SC 0S SC 1-4L,S SCA 1-4L,S - SCAF 1-4L,S A1 A2 B C1 C2 D1 D2 D3 E1 E2 E3 F W1 W2 Z1 Z2 SC-0S 14.65 0.00 13.19 13.19 0.00 8.07 11.22 8.86 9.53 1.67 13.27 0.35 7.87 31.50 1 1/16-12 UNF 1 1/16-12 UNF SCA-0S 14.65 0.00 16.06 13.19 0.00 8.07 11.22 8.86 9.53 1.67 13.27 0.35 7.87 31.50 3/4-12 JIC-8(M) 1 1/16-12 UNF SCAF-0S 14.65 15.20 16.06 13.19 13.54 8.07 11.22 8.86 9.53 1.67 13.27 0.35 7.87 31.50 3/4-12 JIC-8(M) 1 1/16-12 UNF SC-1L,S 14.76 0.00 19.88 13.58 0.00 12.60 11.22 14.17 11.38 1.97 1.87 0.35 11.81 39.37 1 1/16-12 UNF 1 1/16-12 UNF SCA-1L,S 14.76 0.00 22.68 13.58 0.00 12.60 11.22 14.17 11.38 1.97 1.87 0.35 11.81 39.37 1 1/16-12 JIC-12(M) 1 1/16-12 UNF SCAF-1L,S 14.76 15.35 22.68 13.58 18.70 12.60 11.22 14.17 11.38 1.97 1.87 0.35 11.81 39.37 1 1/16-12 JIC-12(M) 1 1/16-12 UNF SC-2L,S 18.50 0.00 23.70 15.16 0.00 15.35 11.81 16.93 15.31 1.97 1.87 0.35 15.75 59.06 1 1/16-12 UNF 1 1/16-12 UNF SCA-2L,S 18.50 0.00 28.66 15.16 0.00 15.35 11.81 16.93 15.31 1.97 1.87 0.35 15.75 59.06 1 5/16-12 JIC-16(M) 1 1/16-12 UNF SCAF-2L,S 18.50 19.69 28.66 15.16 20.28 15.35 11.81 16.93 15.31 1.97 1.87 0.35 15.75 59.06 1 5/16-12 JIC-16(M) 1 1/16-12 UNF SC-3L,S 20.87 0.00 28.15 17.72 0.00 18.50 14.17 19.69 17.28 2.17 2.46 0.35 19.69 78.74 1 1/16-12 UNF 1 1/16-12 UNF SCA-3L,S 20.87 0.00 33.07 17.72 0.00 18.50 14.17 19.69 17.28 2.17 2.46 0.35 19.69 78.74 1 5/8-12 JIC-20(M) 1 1/16-12 UNF SCAF-3L,S 20.87 22.05 33.07 17.72 23.03 18.50 14.17 19.69 17.28 2.17 2.46 0.35 19.69 78.74 1 5/8-12 JIC-20(M) 1 1/16-12 UNF SC-4L,S 20.87 0.00 28.15 17.72 0.00 18.50 14.17 19.69 17.28 2.17 2.13 0.35 19.69 78.74 15/16-12 UNF 15/16-12 UNF SCA-4L,S 20.87 0.00 33.07 17.72 0.00 18.50 14.17 19.69 17.28 2.17 2.13 0.35 19.69 78.74 1 5/8-12 JIC-20(M) 15/16-12 UNF SCAF-4L,S 20.87 22.05 33.07 17.72 23.03 18.50 14.17 19.69 17.28 2.17 2.13 0.35 19.69 78.74 1 5/8-12 JIC-20(M) 15/16-12 UNF 5