DAZZLE TM series Cassette Type Fan Coil Unit. FC-NHDU4 Cassette Type Fan Coil Unit 340~2380 m 3 /h

Similar documents
Duct Type Fan Coil Unit. Air flow: 680~4590m 3 /h Cooling capacity: 3.7~22.6kW

ERACS.C-N Higher efficiency air-cooled screw pump

Water-cooled Centrifugal Chiller

LOW STATIC HYDRONIC DUCTED UNIT

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Catalog C: McQuay Horizontal Concealed Fan Coil Unit

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Product Specifications. Vertical Floor Consoles By First Co.

SECTION FAN COIL UNITS

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

Ceiling Concealed High Volume Chilled Water Fan Coil Unit (50/60Hz)

YAH SERIES FAN COIL UNITS

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

50TM COMBINATION HEATING/COOLING UNITS

Midea Ducted and Cassette Split Systems. Maximum versatility, maximum value.

THIN PROFILE CENTRIFUGAL FAN COIL UNITS SLIM

Midea Ducted and Cassette Split Systems. Year round comfort, all around the house.

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

39G Air Handling Unit

On the cover Integrated professional services designed for your unique business need.

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

MHW Air Handling Unit (50/60Hz)

50TM TFF COMBINATION HEATING/COOLING UNITS

SELF-CONTAINED VERTICAL AIR COOLED PACKAGE AIR-CONDITIONERS

Product Catalog. DCHC Horizontal Concealed Chilled Water Fan Coil with DCBL Motor Airflow: 180~2380 m 3 /h

R410A50Hz Universal Outdoor Series Technical Manual

THE CARRIER COMFORT LINE

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

EHH SERIES DRAW THROUGH FAN COILS CFM

50HJQ004, 005, 006, 007, 008 & 012 SINGLE-PACKAGE HIGH-EFFICIENCY HEAT PUMP UNITS WITH FIELD-INSTALLED ELECTRIC HEAT

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

(Thin)DBFP (Ultrathin)DFP

Advance Release September 2009

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

Hi - Wall Split Systems 12K - 18K - 24K

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

MODULAR CHILLER. R410a R22

WATER CHILLER UNITS AIR COOLED CONDENSER CENTRIFUGAL FANS HEAT PUMP. EWCBZ COOLING ONLY. EWCZ

Highly Efficient,Powerful Heating and Cooling.

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

"SWVP - SWHP" COMMERCIAL WATER SOURCE HEAT PUMPS & AIR CONDITIONERS

VERSO Air Handling Units

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

APPLICATION GUIDE FLATAIR FMC - H FIC - H FSC - H. Horizontal packaged air conditioners kw FLATAIR AGU-MSL E. lennoxemeia.

technical data Fan coil unit FWB small duct unit

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

SECTION AIR HANDLING UNIT

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

SELF CONTAINED HORIZONTAL AIR CONDITIONERS WATER COOLED CONDENSER (COAXIAL REFRIGERANT-WATER HEAT EXCHANGER)

AIR HANDLER SPECIFICATION

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

2017 HYDRONIC SYSTEMS MINI CHILLER FULL DC INVERTER. AIR-TO-WATER HEAT PUMP cooling - heating

FAN COIL UNITS LASER / LOW BODY / CONCEALED

VERSO Air Handling Units

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

Fans Air Handling Units Air Distribution Products Fire Safety Air Curtains and Heating Products Water terminals SYSWALL. Wall mounted fan coil units

42GWC Hydronic Cassette Fan Coil Units

Residential and Light Commercial Ductless Systems Catalog

VERTICAL FAN COIL UNITS

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

AirV Standard-Profile RV Air Conditioning

TOSHIBA AIR CONDITIONING

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

WJH4 Product Specifications

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

CLIMATAIR PENTHOUSE AIR HANDLING SYSTEMS

A. Product Data: Include rated capacities, operating characteristics, furnished specialties, and accessories.

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

Modular Air Cooled Scroll Chillers

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

CATALOGUES SUMMARY - WCHBZ Pages WCHZ Pages 19-42

Horizontal Water Source Heat Pumps And Cooling Only Unit

ELFODuct MP. Technical Bulletin. New generation horizontal and vertical built-in water-source ductable terminal for medium and large systems

KCC Centrifugal Fan Air Cooled Condensers

Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type. R410A50Hz Universal Outdoor Series Technical Manual LCAC/2016.

UNIVERSITY OF MISSOURI Central Station Air-Handling Units March

Modular Air Handling Unit

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

Commercial High-Efficiency Condensing Units

40 RM/RMS Packaged Air-Handling Units

Large Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

Rosemex Products 96 VENTILATION CLIMATAIR COMPARTMENT AIR HANDLING UNITS

SKYPAK II, 3 Ton Series, gives you a

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

SKYPAK II Heating & Cooling Self Contained Packages

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

MODULAR AIR HANDLING UNIT. Models: FAC / FMC / FBC

Transcription:

DAZZLE TM series Cassette Type Fan Coil Unit FC-NHDU4 Cassette Type Fan Coil Unit 340~380 m 3 /h

Cassette Type Fan Coil Unit Casing Unit Features FC-NHDU4 series is the cassette type fan coil unit of Climaveneta. They are ideally designed with versatile configuration and adoption for all applications with -pipe system and 4-pipe system. The units shall guarantee lower pressure drop of air side and water side in accordance with different installation requirement. The -pipe system units shall be constructed with one coil which can interchange the mode between heating and cooling in specific condition. And the 4-pipe system units are characterized by coils, resulting in the independent operation of heating and cooling mode. The cooling and heating mode of 4-pipe system also can be exchanged upon different requests in different areas. The casing shall be manufactured by Grand 1 galvanized steel sheet with extruded treated. The thermal resistance material shall be integrally attached to the exterior surface of the casing and installed with seamless connection method preventing the condensate occurs at the unit exterior surface. NHDU4 Luxury Cassette Type Fan Coil Unit (with condensate pump) The fresh air inlet and air inlet bypass are equipped in the standard configuration, and they shall be installed as an option depending on customer s requirement. Fresh air inlet Bypass air inlet The minimal height of unit is 60mm ideally fitting for the installation of compact space in the ceiling.

DAZZLE TM series Front Panel The front panels of Cassette Type Fan Coil Units are manufactured by ABS material, and the air return section shall be fixed with removable grills, resulting in the convenient replacement and cleaning of filters. The electric diffuser at the air outlet section shall adjust the airflow direction for specific requests Optimized Air Diffusion Configuration Preventing the condensation on the front panel of units and the dirt on the ceiling near the airflow outlet efficiently. Typical air diffusion type The airflow moving along the ceiling make the dirt occurs. Optimized air diffusion type by Climaveneta The upward airflow is limited Coil The reasonable water flow configuration shall be designed to ensure the balance of cooling load between the water side and air side, as well as the matching of cooling load and airflow rate. The coils shall be made of hydrophilic aluminum fins which can prevent the film condensation efficiently and discharge the condensate fluently, resulting in the reduction of the thermal resistant and air resistant. The noncorrosive hydrophilic coat can expand the working life of drain pans also. The exclusive fins shall distribute the air adequately and maximize the heat transfer efficiency. Coils are annular type designed with the possibility to minimize the blind angle of heat transfer, finally guaranteeing the 4-way heat exchange ability. The headers shall be made of copper with ideal performance of water flow configuration. Fan Non-direction, one-inlet centrifugal fan shall be fixed. And oversized fan wheel made of thermoplastic ABS material shall be factory dynamical balance tested to ensure the reliable operation. Motors shall be equipped with low-speed, total-hermetic, 3-speed,free-lubricated scroll bearing. Unit foundation shall be installed with rubber collars to insulate the vibration, finally reducing the noise level. Wire cables shall be protected with specific covers for the reliability of units. The motors, fans and heat exchangers shall be performance match tested strictly to guaranteeing the motors working at the highest efficient performance with low noise operation. 3

Cassette Type Fan Coil Unit Condensate Pump The condensate pumps shall be expected to lift the condensate for 850mm from the ceiling. And the units without condensate pumps shall be offered upon customer s requirement also. Condensate Pump Performance Data: Max head Max water flow Supply power Overheat protection Noise level(1m away) Protection level Dimension(mm) 850mm 95L/h 9W 0V 50Hz Impedance protection 8dBA) IP0 or IP54 LxWxH=88x75x93 Drain Pan The oversized drain pans shall be fixed with well thermal insulation protection on the exterior surface preventing the leakage and stagnant condensation. Control system Both wireless remote controllers and wall-mounted thermostats shall be provided for customer as an option to regulate the operation of units accurately. And the control system could exchange the operation mode in different applications. Operation Mode A Auto. Mode Cooling Mode Humidification Mode Ventilation Mode Heating Mode 4-Hour programmable timer shall be friendly designed keeping the excellent balance between comfort request and energy saving, which presenting the exclusive humanization care of Climaveneta. Timer operation Circulating Timer Turn on at setting time Turn off at setting time Model Nomenclature FC 00 NHDU4 Y 1 3 4 5 1 Fan Coil Unit Airflow: x 1.7m 3 /h 3 Model NHDU4 Luxury type (with condensate pump) 4 Pipe system :-pipe fan coil unit 4:4-pipe fan coil unit 5 Controller Y:wireless controller; X:wall-mounted thermostat; None:without controllers 4

DAZZLE TM series FC-NHDU4- Cassette Type Fan Coil Unit (-pipe,with condensate pump) Performance Data Model 00 300 400 500 600 800 1000 100 1400 H 370 50 710 880 100 1360 1700 040 380 Airflow M m 3 /h 300 410 550 70 850 1110 1400 1670 1950 L 0 90 400 550 680 860 1100 1300 150 Cooling capacity H M L m 3 /h 1.95 1.65 1.15 3.06.45 1.75 3.7.90.10 4.75 3.91 3.05 5.60 4.70 3.80 7.0 6.00 4.6 9.05 7.50 5.60 10.80 9.10 7.00 1.60 10.50 8.50 Heating capacity H M L m 3 /h.97.40 1.78 4.75 3.75.60 5.77 4.47 3.5 7.30 5.98 4.57 8.50 7.10 5.70 10.95 8.95 7.50 13.70 11.35 8.80 16.50 13.50 10.60 19.80 16.0 1.60 Water flow LPM 6 8.8 10.7 1 13.7 16 1 6 31 Noise level db(a) 37/34/30 39/36/33 41/38/35 40/35/31 43/40/37 46/39/33 48/41/38 50/43/39 5/46/39 Supply voltage 0V-50Hz Supply power W 37/3/3 4/36/5 59/48/35 67/51/38 85/67/46 13/115/87 147/15/114 18/165/14 15/179/159 Motor current Amp 0.17 0.19 0.7 0.31 0.39 0.6 0.68 0.84 0.98 Controller Wireless controller or wall-mounted thermostat Water pressure drop kpa 11.8 1.9.1 17.6 18.5 8.4 33. 35.9 38.4 Drain pipe size mm 6 Weight kg 4 4 6 33 34 34 40 41 4 Connection type Internal threaded on unit pipe Water pipe inlet outlet Inch Inch ZG 3/4 ZG 3/4 Note: The information in the table is based on the following testing condition Rated testing condition Temp. DB ( ) Temp. WB ( ) Temp. water inlet ( ) Water temp. difference ( ) Nominal cooling mode 7 19.5 7 5 Nominal heating mode 0 60 Noise level Unit illustration Rated airflow The measurement have been taken on surfaces positioned at d=1m distance from the unit in a standard anechoic chamber (<17dB (A)). LPM means litre per minute, 1LPM=0.06m 3 /h stands for the airflow while the exterior static pressure is 0Pa 5

Cassette Type Fan Coil Unit FC-NHDU4- Cassette Type Fan Coil Unit(-pipe,with condensate pump )Dimension Data 1 W1 D D W1 1 Airflow inlet Airflow outlet 3 Water inlet 4 Water outlet 5 Drain pipe outlet 6 Wire connection hole 7 Air discharge duck 8 Threaded holes for hangers(φ1 7 deep hole) 9 Fresh air inlet (flange connection) 10 Terminal box 11 Exhaust valve Note: The NHDU4 luxury type units shall be fixed with condensate pump. W*W 7 5 10 7 9 B 3 C C1 G C C1 E H H1 X 10 10 8 A 9 7 4 11 6 F X Dimension Data Model W1 W H1 H A B C1 C D E F G FC-00 FC-300 FC-400 FC-500 FC-600 FC-800 FC-1000 FC-100 FC-1400 650 574 318 89 616 53 14 137 379 43 4 117 850 730 318 89 769 433 14 137 450 43 4 117 1050 930 318 89 969 633 14 137 650 43 4 117 6

DAZZLE TM series Installation, Operation and Maintenance Installation---Make sure that the all components inside shall not collide with each other and no dirt shall drop into the fan, motor and heat exchanger. The unit shall be installed in the middle of the ceiling ensuring the optimal air diffusion. Air Duck---The filter shall be installed at air inlet to prevent dust to block the fin and make sure good heat exchange efficiency. Water Pipe Connection---Water connections are inlet from the bottom and outlet from the top; Flexible connectors are suggested for both inlet and outlet; The torque shall be less than.5kg m during installation; All water pipes shall be well insulated. And all bolt connections shall be insulated and sealed by material of PTFE belt. The drain pipe shall be mounted with proper gradient, no squash, no bending. Union joint with spanners shown in the drawing Hanger Drain lifting Clamp (as optional) Flexible drain pipe i >1/100 Electrical Connection---The unit must be earthing, All electrical wires exposing to the air should well bonded to connectors before attach to unit (Wire connection shall comply with the wire diagram offered by the company). Start-up Procedure---After proper installation, the drain pan, fan casing and coil must be clean; Then check all field connections of pipes and wires; And now the unit can be started. The 3-speed switch is recommended to be turned on from high speed. Operation---The lowest water temperatures for unit inlet is ºC for cooling and highest temperature is 80 ºC for heating. The manual vent valve shall be regularly opened to release the air in the pipe system. The system water shall be softened and meet the water quality requirements. Maintenance---Fan coils and filters shall be cleaned regularly by blowing with compressed air in opposite direction of airflow. Clean water should be charged in the coils to reduce the rust while the unit stops working. And in winter, anti-freeze method shall be considered. Filter Cleaning---The customer shall be suggested to clean the front panel and filters only! Before the cleaning, always turn off the main power! The filters shall be cleaned by soap water. The strong oxidant, strong acid or alkalis liquid are forbidden to use! The front panel shall be cleaned by wet rag with soap water. And the filters shall be treated with the proper method in the manual book. The installation, operation and maintenance of units shall comply with the Installation manual book of Cassette Type Fan Coil Unit. 7

Climaveneta Italy: 36061 BASSANO DEL GRAPPA (VICENZA) ITALIA - VIA SARSON 57/c TEL. +39 / 044 509 500 (r.a.) - TELEFAX +39 / 044 509 509 E-mail:info@climaveneta.com http://www.climaveneta.com Climaveneta China: No,88 Baiyun Road Xinghuo Developing Zone,Shanghai,China Post Code:01419 TEL: +86-1-57505566 FAX: +86-1-57505797 E-mail:info@climaveneta.com.cn http://www.climaveneta.com.cn Climaveneta Hongkong: Room 003,CCT Telecom Building, 11 Wo Shing Street,Fotan,Shatin,N.T.,Hongkong TEL: +85-6871755 FAX: +85--6873078 E-mail:info@climaveneta.com.cn http://www.climaveneta.asia Climaveneta Vietnam: 3rd Floor MEKONG Tower-35-41 Cong Hoa str Ward 13 Tan Binh Dist HCMC TEL: +848 66 9966 FAX: +848 66 9977 E-mail: info@climaveneta.com.cn http:// www.climaveneta.com All specification and data are subject to change without notice B741 CCU/01-11-013 EN-SH