Fluorescence is the conversion of one frequency of electromagnetic radiation to another frequency by a material

Similar documents
I-320 SERIES AC EMERGENCY LIGHTING EQUIPMENT

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

Installation Instructions

Occupancy Sensor Operation with Lighting Fixtures

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 3LERHZ Series Class I, Div 2 Combo Unit. Installation instructions

AMBIANCE LINEAR 40 AMBIANCE LINEAR 60 AMBIANCE LINEAR 100 SAFETY INFORMATION AND OPERATIONS MANUAL

LED Lighting: Technology Selection and System Commissioning Course Number: CXENERGY1519

Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL

Installation Instructions

SECTION INTERIOR LIGHTING

150W Explosion Proof LED Light - 5' Tall Base Stand Mount - 24" Stand - Class I Div 1 C&D V

THE COMPLETE GUIDE TO OUTDOOR WALL LIGHTS

Data Bulletin. Determining the Cause of AFCI Tripping Class 760

PSO Business Rebates Retrofit Lighting Technical Requirements

1 x4 Dimmable LED RetroFits

WL24000 Series Reflectorized Troffer Luminaries

Bdl60u Fluorescent Emergency Ballast

LUCE 1 TL. specifications: internal. specifications: external. ordering logic. builder. Job/Location:

Honeywell Durafit LED Retrofit Kit

Vaporproof White LED Light - 10 Watts - Non-Metallic - Corrosion Resistant Lumens

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

150 Watt Explosion Proof LED Light - 5' Tall Base Stand Mount - 24 Inch Stand - Class I Div 1 C&D

CL001 >400 Watt lamp basecase, up to 600 Watt replacement fixture $95.00 Fixture

Related Sections: TBD. Effective Date: January 1, 2016

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

Model 3300 Technical Support and Installation Manual

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

Bosch 80% AFUE Gas Furnace BGS80 Model

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

SECTION INTERIOR LIGHTING

Non-Cutoff and Semi-Cutoff Wall Pack Primary Use and Edits to Outdoor Wall-Mounted Luminaire Primary Use

1 General Description

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

A. Furnish and install luminaires, lamps, ballasts and in-line fuses as herein specified and shown on the Drawings.

Explosion Proof Light - Base Stand Mount - 16 Inch Watt LED - Class I Div 1 C&D

e Heater/Exhaust Fan/Light User s Guide

Business Customer Information. Account Number (9 digits) Account Holder Name Phone (As shown on your utility bill) Service Street Address

What Markets we serve:

How to light a small storage space rabdesign.ca 1

The Da-Lite Difference.

Home Fire CBI Electric Series HF36CBI HF42CBI HF60CBI

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

LED FIXTURE CATALOG. Shining light into the future

2018 Commercial Lighting Retrofit Rebate Program

FR-A180 FR-A360. Occupancy detector. Use

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

Pathway Lighting. Introduction

Gallery Electric Fireplaces

Electrical safety tips

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

SERVICE MANUAL FOR ROOF TOP AIR CONDITIONERS

READ AND SAVE THESE INSTRUCTIONS

Energy Management Plan

Electrical Inspection Lighting & Power

LED RETROFIT SOLUTIONS

Industrial 100 Watt Ultraviolet LED Light Fixture - Paint Spray Booth Approved Nanometer

30-YEAR LIMITED WARRANTY

SAVE THESE INSTRUCTIONS INSTALLATION INSTRUCTIONS EMERGENCY FLUORESCENT BATTERY PACK MODEL PS300, PS600, PS1400

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

Ceiling Mount Air Purification System

Quartzone. Infrared Quartz Tube & Metal Sheathed Electric Heaters. Owner s Manual. File E COMFORT HEATERS for INDOOR* and OUTDOOR** USE

33 Watt Low Voltage LED Fixture for Hazardous Location Lighting - Low Profile Linear Fixture - C1D2

e Bath Fan with Light User s Guide

LED RETROFIT CONVERSION KITS

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

WZ-T8-W18 T8 LED Tube Light

100W Explosion Proof Ultraviolet Portable LED Fixture - 365NM - EXP Cord Caps - 150ft Cord

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2

Fire Patterns. Introduction. Skills Objectives. Fire Effects and Fire Patterns (2 of 2) 12/20/ Knowledge Objectives

GARAGE HEATER WITH REMOTE INSTRUCTION MANUAL MODEL: HA24-100E HA24-150E. Figure 1

INSTALLATION INSTRUCTIONS

HeatDish Plus INSTRUCTIONS IMPORTANT SAFEGUARDS. parabolic electric heater

2018 Instant Lighting Rebates Product Catalog

EarthTronics products. About us. Where efficiency meets innovation. T5 & T8 Linear. Founded in 2007, EarthTronics, Inc. is a Michigan based

ELECTRICAL SYSTEMS ASSESSMENT Hanover High School

Gallery Electric Fireplaces

School Fire Safety. A Guide for Educators. saskatchewan.ca

Eligible Prescriptive Measures List:

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed

Electrical Safety Tips. Help us keep you safe.

Installation & Maintenance Instructions

IMPORTANT SAFETY INFORMATION:

Air Conditioning Operation and Troubleshooting Matt Dunham

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Universal Lighting Technologies is a subsidiary of Panasonic Electric Works Co., Ltd., a member of the Panasonic Group. Technical Product Information

INSTALLATION AND OPERATION INSTRUCTIONS FOR

ZCR 3824 SAFETY INFORMATION AND OPERATIONS MANUAL

LANDSCAPE FULLVIEW SERIES MODEL 4015 MODEL 6015 MODEL 8015 MODEL MODEL SAFETY INFORMATION AND OPERATIONS MANUAL

Explosion Proof 70 Watt Low Profile LED Light Fixture Lumens - C1D1 Group B - Hydrogen Rated

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

ILLINOIS INSTITUTE OF TECHNOLOGY SAFETY POLICY COMMITTEE OFFICE SAFETY POLICY

Homeowner s Installation Instructions & Operating Manual

Innovative Lighting R-Series Vertical Refrigeration

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Versatility. Maximum Energy Savings

GENERAL LABORATORY REFRIGERATORS AND FREEZERS Installation, Operation and Maintenance Instructions

WINDSOR FOREST HIGH SCHOOL HVAC REPLACEMENT ADDENDUM #2 SAVANNAH CHATHAM COUNTY PUBLIC SCHOOL SYSTEM FEBRUARY 18, 2016

LED RETROFIT CONVERSION KITS

Ni - Cd THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

Transcription:

Fluorescent Lighting Developed around turn of century Commercially available in 1938 by GE Presented at 1939 Worlds Fair Made efficient lighting possible during WWII in factories and warehouses Fluorescence is the conversion of one frequency of electromagnetic radiation to another frequency by a material Copyright 1 SYTEK Consultants Copyright 2 SYTEK Consultants Fluorescent Lighting Operates by maintaining a low pressure mercury arc in a linear glass tube Mercury arc produces UV radiation UV strikes phosphor on inside of lamp Phosphor converts UV to visible light Most of input power creates light, not heat Fluorescent Lamps Lamps are a linear soft light source Last between 10,000 to 25,000 hours Run cool (about 150 F at their ends) Very efficient source of light About 5 times more light per watt than Incandescent Systems Copyright 3 SYTEK Consultants Copyright 4 SYTEK Consultants Fluorescent Lighting Drawbacks Lamps require additional equipment Ballast Starter More wire Lamps contain Mercury Cost more to install Why do fluorescent lamps need a ballast? Lamps require more than 120 Volts to start. Once started, lamps want to draw all the available current. Once started, lamps will immediately burn out without ballast Lamps have negative resistance behavior Copyright 5 SYTEK Consultants Copyright 6 SYTEK Consultants 1

Incandescent v. Fluorescent Purpose of a Ballast Incandescent filament resistance goes up when it is heated, thus limiting the current flowing through the lamp. In fluorescent lamps, the resistance of the mercury arc declines as more current flows through it. The ballast has several purposes: Transform the input voltage to high enough level to strike the arc in the tube Limit the current flowing through the tube (typically between 0.2 to 0.8 Amps) Copyright 7 SYTEK Consultants Copyright 8 SYTEK Consultants Lamp Construction Filament Lead In Wires Press Stem Supports Copyright 9 SYTEK Consultants Copyright 10 SYTEK Consultants Lamp Operation Lamp Operation Phosphor Coated Glass Clear Glass Copyright 11 SYTEK Consultants Copyright 12 SYTEK Consultants 2

Lamp Starting Basic Fixture Types Recessed T bar troffers Most of fixture above ceiling C channel strips Typically suspended or surface mounted Low Profile Wrap Arounds Surface mounted Has lens wrapped around fixture Copyright 14 SYTEK Consultants Typical Troffer Interior of Troffer Copyright 15 SYTEK Consultants Copyright 16 SYTEK Consultants Interior of Troffer Top Surface of Troffer Copyright 17 SYTEK Consultants Copyright 18 SYTEK Consultants 3

C Strip Fixture Interior of C Strip Fixture Copyright 19 SYTEK Consultants Copyright 20 SYTEK Consultants Low Profile Wrap Around Interior of Low Profile Wrap Around Fixture Copyright 21 SYTEK Consultants Copyright 22 SYTEK Consultants Fluorescent System Types Various Fluorescent Ballasts Basically three common types of systems Pre-Heat Rapid Start Instant Start Can be identified by wiring system Copyright 23 SYTEK Consultants Copyright 24 SYTEK Consultants 4

Pre-Heat System Mostly used today in desk lamps Original system Often used starter or push and hold button Starter Copyright 25 SYTEK Consultants Copyright 26 SYTEK Consultants Rapid Start System Lamps come on quickly, but with visible delay Ends of lamps heated inside Long lamp life Rapid Start Lamp Ends Copyright 27 SYTEK Consultants Copyright 28 SYTEK Consultants Instant Start System Lamps come on instantly Use high voltage to blast arc down tube Short lamp life Lower cost to buy and install Instant Start Lamp End Copyright 29 SYTEK Consultants Copyright 30 SYTEK Consultants 5

T-12 4, 6 & 8 foot Still very common T-8 Lamps Sizes Used mostly with lower current electronic ballasts Physically interchangeable with T-12 lamps Not electrically interchangeable with T-12 lamps T-5 For electronic ballasts only Very efficient Copyright 31 SYTEK Consultants Copyright 32 SYTEK Consultants Purpose of a Ballast Types of Ballasts The ballast has several purposes: Transform the input voltage to high enough level to strike the arc in the tube Limit the current flowing through the tube (typically between 0.2 to 0.8 Amps) Magnetic Ballasts Electronic Ballasts Copyright 33 SYTEK Consultants Copyright 34 SYTEK Consultants Magnetic Ballasts Original type developed Proven technology Operate lamps at 60 cycles per second Lower efficiency light source Fewer parts, high reliability Lower cost Magnetic Ballast Operation Copyright 35 SYTEK Consultants Copyright 36 SYTEK Consultants 6

Magnetic Ballast Interior Electronic Ballasts Very high operating efficiency Operate lamps at high frequency (20 to 40 thousand cycles per second) Large number of components inside Expensive compared to magnetic ballasts Becoming more popular Required to meet most energy codes Copyright 37 SYTEK Consultants Copyright 38 SYTEK Consultants Electronic Ballast Operation Electronic Ballast Interior Copyright 39 SYTEK Consultants Copyright 40 SYTEK Consultants Electronic and Magnetic Ballasts Electronic Ballast Potting Compound Softens around 250 to 270 F Liquid at about 360 to 380 F Inserted into ballast at about 380 to 400 F Flash point > 500 F Auto-ignition temperature > 800 F Magnetic Ballast Copyright 41 SYTEK Consultants Copyright 42 SYTEK Consultants 7

Fluorescent Fixtures as Fire Causes Fires caused by wiring in fixture Fires caused by failures at the lamp holders Fires caused by the ballast Fluorescent Fixture Fire Causes Pinched and arced wires Rare Often arcing is result of fire heat impingement Overheated /Arcing lamp holders Usually contact with combustibles or Close proximity of lens to lamp holder Arc penetrations through ballast case May be through top, bottom or sides Copyright 43 SYTEK Consultants SYTEK Consultants Typical Reflector Fires Caused by Wiring in Fixture Fairly rare. Most arcing in fixtures is caused by fire attacking the fixture. Arcing in fixture may penetrate fixture body. Arcing may ignite light fixture lens. Pinched wire may arc producing sparks. SYTEK Consultants Copyright 46 SYTEK Consultants Fire Induced Arcing in Fixture Result of Wire Pinched Between Reflector and Channel Fixture is a heat absorbing fin. Think of the fixture as a piece of conduit. Should be considered during arc mapping. SYTEK Consultants Copyright 48 SYTEK Consultants 8

Fire Damage to Fixture Wiring Copyright 49 SYTEK Consultants Copyright 50 SYTEK Consultants Fires Caused By Lamp Holders Typically result of poor connection to lamps Improper seating of the lamps Improper spacing of lamp holders Improper installation of lamp holders More common with higher current lamps Generally only occurs with Instant Start circuits Ballast is designed to maintain an arc and it will! Copyright 51 SYTEK Consultants Copyright 52 SYTEK Consultants Fires Caused by Lamp Holders Proper Insertion Lamp holders are made of some what retardant materials. Lamp holders may be made of thermoset or thermoplastic materials. Arcing my ignite dust or lint. Typically involves fixtures with lenses or combustibles in close proximity to lamp holders. Typically not associated with troffers. Copyright 53 SYTEK Consultants Copyright 54 SYTEK Consultants 9

Proper Insertion Proper Insertion Copyright 55 SYTEK Consultants Copyright 56 SYTEK Consultants Incorrect Insertion Copyright 57 SYTEK Consultants Photo Courtesy of ATF National Laboratories Fire Research Laboratory Photo Courtesy of ATF National Laboratories Fire Research Laboratory Photo Courtesy of ATF National Laboratories Fire Research Laboratory 10

Warning Sticker Locking Lamp Holders Copyright 61 SYTEK Consultants Copyright 62 SYTEK Consultants Bi Pin Lamp Holder Overheating Bi Pin Lamp Holder Overheating Copyright 63 SYTEK Consultants Copyright 64 SYTEK Consultants Bi Pin Lamp Holder Overheating Damage to Lamp Copyright 65 SYTEK Consultants Copyright 66 SYTEK Consultants 11

67 68 69 70 71 72 12

73 74 75 76 77 78 13

Some Ballast Fire Producing Failures Causes of Ballast Overheating Ballast Overheating Upward arcing events Downward arcing events Arcing through the side of the fixture 79 81 Coil Failure In Ballast 80 Overheated Coil in Ballast Overheated Coil in Ballast Shorting of coil windings in the transformer Failure of power capacitor End of life of instant start lamps Internal arcing Improper voltage or lamps 82 Coil Failure In Ballast 83 84 14

Coil Failure In Ballast Coil Failure In Ballast 85 Arc Penetrations Through Ballast Case 86 Arc Penetrations Through Ballast Case Probably leading cause of magnetic ballast fires Can occur in thermally protected ballasts Can burn hole through fixture Can ignite materials above fixture such as: Can occur through side of ballast case Can exit top or side of fixture and ignite: Lens Combustibles below Lint or dust Light weight materials Wood Plywood Combustible ceiling tiles 87 88 89 90 15

Ballast With Arc Penetration 91 Fixture with Arc Hole 92 Fixture Top with Arc Hole 93 94 95 96 16

97 98 Multiple Arc Penetrations 99 100 Ballast Protection 101 Between 1940 s and early 1960 s, most ballasts in heavy metal fixtures mounted away from combustibles. Around 1960, most manufacturers began to develop protection systems. First NEC code requirements in mid- 1960 s 102 17

Thermal Protection History Ballast Protection History Originally fuses for each ballast recommended Single shot thermal protectors (~260F to 270 F) came next Self-resetting thermal protectors (~ 230 F) became common method of protection Internal capacitor protectors developed 103 UL asked for NEC requirement to be moved back until 1968-1969 1981 NEC states: UL begins Class P listing of thermally protected ballasts UL listing criteria favors self resetting thermal protectors in magnetic ballasts 104 Thermal Protection History Thermal Protection History By 1961, most manufacturers had single shot thermally protected ballasts available In 1962, GSA required thermal protection in ballasts for government buildings In 1965, NEC required new fixtures to incorporate ballast protection The 1965 NEC requirement was postponed to 1967 105 Where fluorescent fixtures are installed indoors, the ballasts shall have thermal protection within the ballast. Replacements for these ballasts shall also be integrally protected From 1968 to 1984, Non-thermally protected ballasts could be replaced with non-thermally protected units. 1984 NEC required all replacement ballasts to be thermally protected. 106 Typical Thermal Protectors Fire History Fluorescent Ballast Fires 900 800 700 600 500 400 300 200 100 0 1977 1978 1979 1980 1981 1982 Source: IAEI News 1978-1983 107 108 18

Self Re-setting Thermal Protectors 109 110 111 112 Resetting Thermal Protectors 113 Most set at 221 F to 239 F May not reset until cooled below 185 F Must be able to operate 10,000 times under load Most are able to operate about 14,000 to 16,000 times before failure Typical cycle is once every 30 to 45 minutes 114 19

How Are Ballasts Evaluated After A Fire? How Are Ballasts Evaluated After A Fire? Post fire examination of ballasts is destructive in nature. Experts should perform the examination. Examination should be in laboratory setting. X-Rays are preferred before disassembly. Fairly well established protocols exist. 115 Potting Compound Condition Low heat - shiny black, soft Medium heat - hard, tough dull black More Heat - hard, brittle, porous gray/black More heat - White powder (remains of sand) Final stage - glass like fusing of sand Can be re-melted Barely re-meltable Bubble size depends upon rate of heating 116 Cross Section of Ballast With Internal Overheating Due to Coil Failure Coil Failure In Ballast Fixture Side Less Charred More Charred Label Side 117 118 119 120 20

Thermal Protector Testing Thermal Protector Testing 121 122 Typical Fire Damaged Protector 123 124 125 126 21

Analysis of Electronic Ballasts Does not have the fire endurance of a magnetic ballast. Do not have the general overheating like magnetic ballasts. Overheating is a component phenomena. Look for localized damage to the circuit board. Look for arc penetrations of the case. Examine the fuse. 127 128 129 130 131 132 22

133 134 135 136 137 138 23

139 Protection of Electronic Ballasts 140 Typical Fuse Early electronic ballasts had resetting thermal protectors. Most electronic ballasts today use fuses instead of thermal protectors UL allows electronic ballasts to be listed as Class P with fuses 141 142 143 144 24

Fixture Paint Condition Fixture paint condition often misleading Must be used with caution NFPA 921 warns Care should be exercised when evaluating heat damage patterns on painted steel surfaces 145 146 147 148 149 150 Fixture Paint Condition Paints will Discolor slightly by 400 F Noticeably darken by 550 F By 700 F will begin to lighten again At 1000 F, paint will turn to chalky white powder Thus, cooler locations may have darker color paint Fire Heated Fixtures 25

151 152 How Are Fluorescent Fixture Fires Investigated? Over-heated Ballast Pattern Find point of origin first! Determine origin both horizontally and vertically Was fire started above or below ceiling? Was fire caused by drop down from above? Determine first fuel ignited Was it in contact with fixture? Is it combustible? Readily ignitable? 153 What To Do How Are Fluorescent Fixture Fires Investigated It is not practical nor proper investigative technique to try to disassemble every ballast in a building to look for a cause of a fire. Identify any possible sources of ignition at the point of origin including light fixtures. 154 155 Document how fixture was mounted Document how the fixture was supplied with power Collect fixture, channel cover, wiring and lamp holders Leave ballast attached to fixture if possible Minimize damage to fixture Collect ceiling materials Gather exemplar fixtures 156 26

What NOT To DO Common Myths Dispose of fixture and channel cover Open or disassemble ballast Lose fixture wiring and lamp holders Remove and open thermal protector Energize the ballast 157 Some Truths 158 Example of Fluorescent Fixture Fire Ballast do cause fires. Lamp holders do cause fires Ballasts can blow up Some ballasts do contain PCB s in their capacitors. The ballast that leaked the most potting compound caused the fire. The lightest ballast caused the fire. The ballast that rattles the most caused the fire. The fire burned inside the ballast can for an extended time. Ballasts can not cause fires. Arc penetrations mean the breaker was defective. Overheating and Arcing in Ballast Causes Low Density Ceiling Fiberboard Tiles to Ignite 159 160 Low Density Ceiling Fire Low Density Ceiling Fire Area Above Suspect Ballast 161 162 27

Side of Ballast After Fire Top of Fixture After Fire Hot Spot Hot Spot 163 164 Ballast Coils Base of Ballast After Fire Arcing Hot Spot 165 166 Example of Long Term Overheating of Ceiling Material 167 168 28

Photo by David Smith 169 Photo by David Smith 171 173 Photo by David Smith Photo by David Smith 170 172 174 29

175 176 Example of Arc Penetration Causing a Fire 177 Fixture Position 178 Top of Fixture 179 180 30

Top of Fixture Top of Fixture 181 Ballast Interior 182 Ballast Interior 183 Ballast Interior 184 Ballast Interior 185 186 31

Thermal Protector Thermal Protector TP failed to open at up to 155C 187 Thermal Protector 188 Thermal Protector 189 190 Thermal Protector 191 32