Brawa-Mix Thermostatic mixing valves

Similar documents
Aquastrom T plus Thermostatic valve with adjustable temperature control range and fixed residual volume flow for circulation pipes

Valves, controls + systems. Local and district heating technology. Innovation + Quality. Product range. for improved.

HERZ Differential Pressure Control Valve 4002

Valves, controls + systems Flow, pressure and temperature balancing

HERZ Regulating valve 4002

Valves, controls + systems. Innovation + Quality. Stations for solar energy and solid fuel boilers Product range

Unibox Individual room temperature control and limitation of return temperature in surface heating systems

Vekotrim. Valves for radiators with integrated valve Double connection fitting with shut-off ball valves for radiators with integrated valves

Mikrotherm. Manual Radiator Valves With presetting

Multilux 4-Eclipse-Set

CATALOGUE NUMBERS. Pressure Reducing Valve (PRV)** Mains Supply. Cold Water Outlets

Self-operated Temperature Regulators Series 43 Temperature Regulators Type 43-1 Type 43-2

Thermostatic valves with radiator connection systems

HERZ-DR-T-90. Radiator Control Valves with Pre-Setting Function by Means of Double Cone, Suitable for Conversion to Thermostatic Operation. H max.

Standard C. Thermostatic Radiator Valve Thermostatic valve body with reversed direction of operation

Radiator valve inserts

Control valves for floor heating systems. Floor Heating Manifolds

TA-MATIC. Mixing valves Thermostatic mixing valve for domestic hot water

Innovation + Quality. Product range. Awards:

Say heating. Say Herz. HERZ-Supply Engineering

For reversed flow direction. Thermostatic Radiator Valves Thermostatic valve body with and without presetting

Thermostatic three-way valve body. Thermostatic Radiator Valves without presetting, with automatic bypass control

Dynalux. Floor Heating Manifolds Underfl oor heating circuit manifold

Valves, controls + systems. Regucor WHS Energy storage centre. Innovation + Quality. Product range. v o. Awards: i y. n n

Thermostatic valve bodies

Signal anodes and sacrificial anodes. Rainwater harvesting. Domestic water system centre. Water filters

V2075, V2077 Flowshare Valve THERMOSTATIC TWO-WAY FLOWSHARE VALVE

Regulux. Return Lockshield Radiator lockshield with consistent presetting and drain-off facility

regulux Radiator lockshield with drain-off facility Pressurisation & Water Quality Balancing & control thermostatic control engineering ADVANTAge

Calypso exact. Thermostatic Radiator Valves With stepless precision presetting

V2880, Therafix Design Thera Design Edition - H-Block with TRV Insert WITH HIGH QUALITY SURFACE FOR DESIGN RADIATORS

E-Z Valve. Thermostatic valves with radiator connection systems For single and two-pipe heating systems

Catalog. Self-operated Regulators Volume 2 Temperature Regulators

ACCREDITED. Function. Code /3 unit without cold water circuit outlet kit

Partner Valve/High Quality Ball Valve LENO MSV-S

manifold, for radiators

Mounting and Operating Instructions EB 2231 EN

Radiator Valve Program

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Regulux. Radiator lockshield with drain-off facility. To be precise.

Thermostatic valve bodies

Standard. thermostatic valve body without presetting

TRV pack Eclipse. Thermostatic valves with radiator connection systems Thermostatic raditor valve with automatic flow control, head and lockshield

Engineering Specifications

CIRCO 6 Solar Circulation Unit

The sealless FLUX F 424

9.0 Systems For Domestic Water Installations

Model T-45NL: Certified in compliance with ASSE 1017, 1069, 1070, and ANSI/NSF 61 PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING AND OPERATING!

Design-Edition. Design-Edition Thermostatic valves and lockshields, sets

PrimusCenter DWC7000. Domestic Water Centre. Product specification sheet

HKF 8180 Operating instructions

AIRTERM DIRT AND AIRTERM MAG COMBINED SELF-CLEANING DIRT SEPARATORS / DEAERATORS

MADE IN GERMANY. Valves, controls + systems Thermal solar energy Stations, controllers, collectors, accessories, service, software

DISCALDIRT deaerator-dirt separator

Installation Instructions

Radiator Connection System, Thermostatic Valve and Return Valve with Shutoff Function

ThermoDual Domestic hot water charging system

MODEL CMA-180UC PARTS MANUAL Rev 1.16

Systems for central heating

CONNECTION OPTIONS FOR MANIFOLDS & CONTROL UNITS

Radiator Trap Radiator Valve

Eclipse F. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

Valves, controls + systems Regudis W Dwelling stations

Installation and operating instructions. DK energy storage and DK energy buffer

Zeparo Cyclone. Automatic air vents and separators Dirt and magnetite separator with Cyclonic technology

Installation and Operation Instructions Domestic hot water module FriwaMini with circulation - DN 15

Eclipse. Thermostatic Radiator Valves Thermostatic radiator valve with automatic flow limitation

New TERMOVAR Loading Unit. The link between bio-energy boiler and storage tank system

FOR INSTALLING AND USING

PORTABLE HYDRANT PN10 1A; 2A; 1B; 2B; 1C; 2C TYPES

caleffi hydronic valves page 1 of 12

TA-COMFORT-S. Prefabricated units Heating interface unit for surface heating and hot water services

Indirect Expansion. USER MANUAL FOR OPERATORS AND PLUMBERS HEAT INTERFACE UNITS

TS RD 7761 RD, 7761 RD

NON-SLAM DYNAMIC ARV FAF 7330

FLOWRETT, TA-UNI. Thermostatic valves with radiator connection system One-pipe

Semi-Automatic Suction Screen Filters 3"-4 Angle. Service & Maintenance Manual

product overview ProControl

INSTALLATION ADJUSTMENT SERVICE THERMOSTATIC WATER MIXING VALVE SERIES LV-981 & LV-982

DirtVec. Dirt Separators For Heating and Cooling Systems.

INSTALLATION ADJUSTMENT SERVICE HIGHLOW THERMOSTATIC WATER MIXING VALVE SERIES XL-32, XL-82

Models Series Series

The sealless FLUX F 424

Automatic Temperature Controller (ATC)

OEM Sensors for HVAC manufacturers Pool water

VIESMANN. Installation instructions VITOCELL 300-B. for contractors. Vitocell 300-B Type EVBA-A. Dual mode DHW cylinder, 300 and 500 l

IMI Heimeier Kit Hydroca ble

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

System illustrations 2013

Airvec. Deaerators For Heating and Cooling Systems.

INSTALLATION 125 PSI (8.6 BAR) MAXIMUM OPERATING PRESSURE

Gas cooler series TC-Standard+

DIRTCAL - DIRTMAG dirt separator

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

TA-Compact-P. Giving you MORE by giving you LESS

Three-way reversing valve

Hand pump JP-02. Hand pump JP-02 for acids, alkalies and water-based chemicals. depending on lever position. The telescopic suction tube is adjustable

Installation, Operation and Maintenance Guide G3600 Series Thermostatic Mixing Valves

Flush individual room control for floor heating systems

Transcription:

Technical information Tender specification: The Oventrop thermostatic mixing valve Brawa-Mix without dead zone mixes hot and cold water according to an infinitely adjustable water temperature. The thermostatic mixing valve is used for the control of the hot water distribution temperature in hot water supply. It is installed in the hot water outlet of water heaters. In heating, the thermostatic mixing valve is used as temperature controller for surface heating or as return temperature limiter. To prevent scalding, the hot water supply is automatically closed if the cold water supply fails within the control range (fail-safe function). Body, stem and bonnet made of according to DIN EN 1982 and DIN 50930-6, with highly sensitive thermostatic sensor in the mixing channel, including fail-safe function within the control range, infinitely adjustable setting of the mixed water temperature with the help of the handwheel, temperature setting may be locked and lead sealed, high-quality control piston resistant to calcification and corrosion. Technical data: Application: Potable water and heating Max. operating temperature: 90 C Max. operating pressure: 10 bar (PN10) Control range: 35 C-65 C Min. temperature difference: 10 C between hot water inlet temperature and mixed water outlet temperature Max. ambient temperature: 30 C Max. pressure difference: 2.5 bar Installation position: any, easily accessible Flow rate: DN 20: k v = 2.3 DN 25: k v = 4.5 DN 32: k v = 4.8 (T mix = 50 C, P stat = 3 bar) Material: Bronze, stainless steel, EPDM, POM, PPE Brawa-Mix : DN 20 G 1 x G 1 x G 1 1300306 DN 25 G 1 1 4 x G 1 1 4 x G 1 1 4 1300308 DN 32 G 1 1 2 x G 1 1 2 x G 1 1 2 1300310 Installation advice: When used in a circulation system, non-return valves for cold water (item no. 1302006) are to be used to avoid volume flows against the direction of flow. Strainers (item no. 1120006 or 1121006) for installation in the hot and cold water inlet of the mixing valve are also recommended to avoid malfunctions caused by impurities. The inline thermometer (item no. 1300952) which can be connected to the mixed water outlet serves the control of the mixed water temperature. DN G B H1 H2 20 1 80 62 117 25 1 1 4 114 62 124 32 1 1 2 114 62 124 Dimensions 2017 Oventrop 1

Accessories: Inline thermometer For the direct connection to the mixed water outlet of the mixing valve, thermometer replaceable during operation without draining the system. Display range 20 C - 80 C DN 20 G 1 x G 1 1300952 DN 25 G 1 1 4 x G 1 1 4 1300953 DN 32 G 1 1 4 x G 1 1 2 1300954 Non-return valve for cold water To avoid volume flows against the direction of flow caused by gravity circulation or pressure differences. Inner parts made of plastic resistant to calcification or stainless steel DN 20 Rp 3 4 x Rp 3 4 1302006 DN 25 Rp 1 x Rp 1 1302008 DN 32 Rp 1 1 4 x Rp 1 1 4 1302010 Strainer Bronze / brass / stainless steel wire basket For installation in the hot and cold water inlet to avoid malfunctions caused by impurities Mesh size 600 µm DN 20 Rp 3 4 x Rp 3 4 1120006 DN 25 Rp 1 x Rp 1 1120008 DN 32 Rp 1 1 4 x Rp 1 1 4 1120010 Mesh size 250 µm DN 20 Rp ¾ x Rp ¾ 1121006 DN 25 Rp 1 x Rp 1 1121008 DN 32 Rp 1 1 4 x Rp 1 1 4 1121010 Insulation shells Expanded polypropylene according to the German Energy Saving Directive, building material class B2 according to DIN 4102 DN 20 1300385 DN 25 / DN 32 1300386 Lead sealing set (10-fold) Lead seal / Locking wire 1089091 Pressure loss p [mbar] Pressure loss p [Pascal] Volume flow V [l/h] Flow chart 2 2017 Oventrop

Tender specification: The Oventrop thermostatic mixing valve Brawa-Mix without dead zone mixes hot and cold water according to an infinitely adjustable water temperature. The thermostatic mixing valve is used for the control of the hot water distribution temperature in hot water supply. It is installed in the hot water outlet of water heaters. In heating, the thermostatic mixing valve is used as temperature controller for surface heating or as return temperature limiter. To prevent scalding, the hot water supply is automatically closed if the cold water supply fails within the control range (fail-safe function). Body made of according to DIN EN 1982 and DIN 50930-6, with highly sensitive thermostatic sensor in the mixing channel, including fail-safe function within the control range, infinitely adjustable setting of the mixed water temperature with the help of the handwheel, temperature setting may be locked, high-quality control piston resistant to calcification and corrosion. Technical data: Application: Potable water and heating Max. operating temperature: 90 C Max. operating pressure: 10 bar (PN10) Control range: 35 C-50 C Min. temperature difference: 10 C between hot water inlet temperature and mixed water outlet temperature Max. ambient temperature: 30 C Max. pressure difference: 5 bar Installation position: any, easily accessible Flow rate: k v = 1.4 (T mix = 50 C, P stat = 3 bar) Materials: Bronze, dezincification resistant brass (DZR), EPDM, stainless steel, PTFE, PPE Brawa-Mix : DN 20 G 1 x G 1 x G 1 1300351 (with 3 collar nuts made of brass) DN 20 G 1 x G 1 x G 1 1300352 (without collar nuts, for compression fittings) Installation advice: When used in a circulation system, non-return valves for cold water (item no. 1302006) are to be used to avoid volume flows against the direction of flow. Strainers (item no. 1120006 or 1121006) for installation in the hot and cold water inlet of the mixing valve are also recommended to avoid malfunctions caused by impurities. The inline thermometer (item no. 1300952) which can be connected to the mixed water outlet serves the control of the mixed water temperature. D 1 L 1 t 15 20 12 18 23 15 22 24 17 Dimensions 2017 Oventrop 3

Accessories: Inline thermometer For the direct connection to the mixed water outlet of the mixing valve, thermometer replaceable during operation without draining the system. Display range 20 C - 80 C Model: DN 20 G 1 x G 1 1300952 Non-return valve for cold water To avoid volume flows against the direction of flow caused by gravity circulation or pressure differences. Inner parts made of plastic resistant to calcification or stainless steel Model: DN 20 Rp 3 4 x Rp 3 4 1302006 Lead sealing set (10-fold) Item no Lead seal / Locking wire 1089091 Strainer Bronze / brass / stainless steel wire basket For installation in the hot and cold water inlet to avoid malfunctions caused by impurities Mesh size 600 µm DN 20 Rp 3 4 x Rp 3 4 1120006 Mesh size 250 µm DN 20 Rp ¾ x Rp ¾ 1121006 Connection fittings Set 1 = 3 tailpipes (with male thread Rp ¾) 1300391 Set 2 = 3 solder tailpipes 15 mm 1300392 Set 3 = 3 solder tailpipes 18 mm 1300393 Set 4 = 3 solder tailpipes 22 mm 1300394 Compression fittings Ø 15 mm 1300381 Ø 18 mm 1300382 Ø 22 mm 1300383 Pressure loss p [mbar] Pressure loss p [Pascal] Volume flow V [l/h] Flow chart 4 2017 Oventrop

Installation example for potable water Installation example as temperature limiter for surface heating Installation example as return temperature limiter Subject to technical modifications without notice. Product range 8 ti 11-EN/10/MW Edition 2017 2017 Oventrop 5