LG HVAC SOLUTION AIR COOLED SCROLL CHILLER

Similar documents
DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

.2 Section Waste Management and Disposal.

Modular Air Cooled Scroll Chillers

AQUASNAP JUNIOR 30RHV

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

MODELS LIST. Nominal Capacity RT

Scroll Water Cooled Chiller

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

3 0 H X C A - H P 2

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

Refrigeration air dryer

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

Screw Water Cooled Chiller SCW210

30HXC-HP Water-to-water Screw Heat Punp. Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw

HITACHI AIR-COOLED WATER CHILLERS - SCREW TYPE -

Refrigerated Compressed Air Dryer

Air Cooled Scroll Chiller / Heat Pump

500 EX Fusion Compressor Series

DAIKIN Huizhou Factory Profile

MODULAR CHILLER. R410a R22

Air Cooled Scroll Chiller

Be sustainable while protecting your business

High Inlet Temperature Air Dryer. Desiccant Air Dryer. Membrane Air Dryer After-Clooler. Air Filter. Oil-Water Separator Automatic Drain Value

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

Call us today! (800)

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

High COP. Water-Cooled Screw Chiller

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

ACORE Filtration Co.,Ltd provides engineering,

Refrigerant air dryers. FD series ( l/s, cfm)

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

MAC N-407 Air-Cooled Chiller

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Zeta Rev LN HP Prochill Bluebox Print Date: 07/17/2017

Aquaflair TRAC-TRAF-TRAH

Tel: Fax: Website:

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

All side discharge units are having high pressure switch (LP switch- Optional) and time delay relay. Compressors are scroll type, Copeland make.

MACH N-407 Heat Pump Air-Cooled Chiller

Service Step by Step Trouble-Shooting Check-List

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

RAS Kp AIR COOLED CHILLERS WITH RECIPROCATING COMPRESSORS AND AXIAL FANS REFRIGERANT R290 LIQUID CHILLERS - AIR COOLED AIR

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

DAIKIN Modular Inverter Air Cooled Chiller

ENGLISH INSTALLATION MANUAL

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

C13-Series Engineering Guide

Call us today! (800)

One World, One Home. Installation and Operation Manual of Commercial Air Conditioner

Call us today! (800)

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

ACMVTECH HIGH EFFICIENCY UNITARY AHU

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

New standard in compressed air treatment, providing Energy Savings up to 99%

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

Precise Temperature Control; Compact Footprint

CHG AIR COOLED WATER CHILLER WITH CONDENSATION BY HELICOIDAL AIR 8 to 17 kw

OACS Outdoor Air-Cooled Central Chillers

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

F Series - Refrigeration dryers

CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

T-16DNH E. DOUBLE EFFECT DIRECT FIRED ABSORPTION CHILLER Cooling Capacity: USRt Heating Capacity: kw

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

Owner s Manual Super-Slim Four-Way Cassette

PHRT HEAT PUMP WITH HYDRAULIC EQUIPMENT AIR / WATER 9 to 18 KW

HNC-120BE-L/R-B HNC-150BE-L/R-B HNC-180BE-L/R-B HNC-210BE-L/R-B COUNTER SHOWCASE MODEL SERVICE MANUAL HOSHIZAKI

Guide Specifications

Leadership, Innovation, Advanced Technology Synergise Here!

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

NFZP Variable Refrigerant Flow Guide Specification

Water-Cooled Dual Compressor Screw Chiller

MAC-A R410A Series Air cooled Modular Chiller

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

MAC-120HE-03 Air-Cooled Chiller

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut

With the world-renowned SIGMA PROFILE

PACKAGED AIR COOLED Product Data Catalog

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Transcription:

LG HVAC SOLUTION AIR COOLED SCROLL CHILLER

Nomenclature Factory Refrigerant: U: China, R410A Cooling Type: A: Air cooled C/O H: Air cooled H/P Capacity: [Air Cooled C/O & H/P ] Unit: 020 : 20RT Line up: B : Master unit C : Slave unit Development sequence : Domestic: 1, 2, 3, Export: A, B, C, U C A S 020 P B T 1 Product Group: C: Chiller Comp.Type: S: Constant Speed Power: T: 440/60/3 P: 380/50/3 9: 380/60/3 Etc: [Air Cooled] T: DX Shell & Tube Eva. / Fin&Tube Cond. Contents Nomenclature 02 Line up 03 Features 04 Specification 08 Performance data 10 Outline dimension 11 P&ID 13 Power wiring 14 Installation of chiller 16 Guide specification 25 02 2017 LG Air Cooled Scroll Constant Speed

Line up Introduction (Unit : usrt) Model 20 30 40 50 500 UCAS series 20, 40RT 480RT Max 12 chillers Up to 480RT by HMI Controller SINGLE MULTIPLE * The capacities of base models are 20RT & 40RT and Max.12 chillers can be controlled by 1 central controller (up to 480RT) LG Air cooled water chillers are complete, self-contained automatic refrigerating units that include the latest in engineering components arranged to provide a compact and efficient unit. Each unit is completely assembled; factory wired, evacuated, charged, tested and comes complete and ready for installation. Each unit consists of multiple air-cooled condensers sections, two or more accessible hermetically scroll compressors, high efficiency evaporator, and thermal expansion valve. High-performance compressor to ensure that the chiller is economical and durable with low vibration and low noise. Highly integrated motherboard is adopted and hence the function is strong and reliable. Advanced control algorithm is adopted to control chiller in advance and hence avoid frequent stoppage protection of chiller. We have set complete safety protection function in order to make chiller safely and reliably run. The linkage control and remote monitoring function of peripheral equipment ensure that the chiller can run safely and the operation and monitoring are convenient. The selection of excellent raw materials and fittings is the key to guaranteeing chiller quality. Excellent reliability and powerful operation The cutting-edge design of Air-cooled scroll chiller accomplishes high performance and reliability for industrial and commercial market. Air-cooled scroll compressors are precisely machined from solid compound metal bar using profound cutting process. Tolerance is maintained within a few microns just like onetenth hair thickness. Robust components with highly skilled assembling process help the compressor last for a long time. LG condenser production technology is already well-known to worldwide air conditioning manufacturing industries because of its leading technologies. World class high efficiency The evaporator uses internally grooved tubes having helical angle which enhanced the refrigerant side heat transfer performance. The V-shape of condenser allows the largest heat transfer surface area for the same footprint, resulting in largest heat transfer performance when the configuration is optimally designed. The LG V-shape condenser coil was designed using numerical 2017 LG HVAC Solution 03

Features Low noise and low vibration and experimental analysis, having optimum air flow path to optimize heat rejection performance. Also, the enhanced condenser fin geometry allows the optimum heat transfer performance at small air side pressure drop, and this reduces the fan-motor power consumption. The fin is pre-coated to prevent corrosion at normal conditions. Low noise and low vibration The unit was designed with a compact structure and robust assembly. The condenser fan is completed with high-efficiency wing style axial fan and direct driven motor for low sound level. The unit configures compressor sound insulation box (Option), which makes LG chillers silent and stable. Installation, start-up Small operating footprint fit most retrofit applications. Factory testing for high reliability. Factory-installed and tested controls help to reduce start up time and minimized extra cost. Display temperatures for each component spot. Standards and codes Chillers conform to the following standards and codes : GB/T 18430.1 - Water chilling (Heat pump) packages using the vapor compression cycle - Part 1: Water chilling (Heat pump) packages for Industrial & commercial and similar applications. (This code is only applied to product manufactured in China) Compressor Hermetically sealed scroll compressor Compressor motor is completely cooled down by suction gas Compressor-crankcase heater is installed to protect extra liquid migration Factory testing / Unit performance testing LG air-cooled scroll chillers are given a complete functional test at the factory. LG computer-based testing programs completely check the components including sensors, wiring, electronics and microprocessor control functions. LG promotes factory performance tests for air-cooled chillers to show that we stand behind the products which are designed and build up. The benefits of a performance test include verification of performance, prevention of operational problems, and assurance of a smooth start-up. Each compressor is run and tested to verify capacity and efficiency. Structural strength analysis Structure is designed to ensure stiffness for various disturbances by steps of structure modeling, meshing, excitation and evaluation. Structural strength evaluation simulation Aerodynamic analysis Condenser part is appropriately designed by aerodynamic analysis like inlet and outlet uniform airflow design and dead zone reduction design. Heat circulation evaluation simulation Eco-friendly refrigerant R410A System designed with Eco-friendly refrigerant R410A which does not harm the ozone layer & protects the environment. The HCFC (R22, R123) series cannot produce any more from 2020 according to the Montreal Protocol for protection of ozone layer. Gold fin (Heat exchanger) [Standard] Gold Fin heat exchanger is corrosion resistant, designed to perform in corrosive environments such as contaminated and humid condition. Improvement in corrosion resistance - In salt spray test, 3 times greater resistance than conventional Fin shape & material composition Section of fin 1 Double-layered Coating Corrosion Resistant + Weather Resistant Hydrophilic layer Anti corrosion layer Aluminum fin Anti corrosion layer Hydrophilic layer Detail of Ocean Gold Fin 2 Double-sided Coating Coating on both inside & outside 04 2017 LG Air Cooled Scroll Constant Speed

Features Dual protection Hydrophilic layer - This film prevents water droplets which causes deterioration of efficiency at the heat exchanger. Hydrophilic coating Anticorroison layer -Epoxy Resin - To improve the corrosion resistance of the Aluminum, we brought the Epoxy Resin. Resin composition outdoors and operate directly from the products installed outside, but it is convenient to operate by extending the HMI up to 500m. HMI(Human Machine Interface) controller has various functions such as cycle monitoring, schedule control and demand control. Chilled water circuit monitoring (Inlet/outlet status, Flow, Pump on/off status) Chiller cycle status monitoring (Unit cycle status, compensating air, compressor discharge temperature, ETC) Max 12 pattern schedule operating Anti freezing operation Error history management/ ETC Mounted in unit (Factory default) Dual protection (Components) LG Corrosion resistance shields corrosive components with dual protection: Double-layered Coating and Double-sided Coating. Components include panels, base pan, brackets and valve supporter. Dual protection coating on core components provides strong protection for both inside and outside 1 Double-layered coating Double-layered coating protects the system not only from damage of harsh weather but also fromdeterioration of metal. MAX 500M 1 Double-layered Coating Corrosion Resistant + Weather Resistant 2 Double-sided Coating Coating on both inside & outside 2 Double-sided Coating Double-sided coating applied in the manufacturing process protects the system both inside and outside at the same time. 500m Remote Controlling Control Room Salt water spray test Components with dual protection passed 1,500 hour salt water spray test, while components with conventional coating started to corrode after 500 hours. Easy control by HMI controller In case of air-cooled products, most of them are installed User Friendly HMI Controller 2017 LG HVAC Solution 05

Features Accessories and options Protection Guard (Standard) Security grilles and panels: Protect the exposed condenser from flying foreign material or debris coils as well as prevent unauthorized access to internal components. Double thickness insulation As a standard, the evaporator shell is insulated with 3/4 (20mm). As an option, it can be insulated with 1-1/2 (38mm). Vibration isolation For installation on building roofs or in sensitive noise areas (hospitals, studios and some residential areas) pre-selected spring type isolators are available as a factory option shipped loose part for field installation. Compressor acoustic enclosure The compressor acoustic enclosure can be provided as an option to reduce compressor sound levels. This enclosure is constructed of painted panels and sound absorbing insulation for maximum sound attenuation. The panels and the sound foam, provide sound damping effect. This panel fastened with bolt for service. The enclosure is factory installed option. Condenser fin To have better protection against corrosion caused by salty air in seashore area or acid corrosive environment, these options are recommended to extend equipment life. The following options are provided with factory mounted. Gold fin (Standard) Aluminum fin with copper tube, this fin is coated with gold colored, this coating provide corrosion protection to heat exchanger compared with bare fin. Standard Copper tube Corrosion resistance coated fin 06 2017 LG Air Cooled Scroll Constant Speed

Features Accessories and options Category Optional list Standard Option Remark Refrigerant Factory charging Operation temperature Leaving chilled water 5~15 C Air ambient -10~48 C BMS Interface Modbus Corrosion protection Gold fin Protection guard Evaporator Security grilles (upper side) Wire grille only Security panels (lower side) Louver panel only 10kg/cm 2 Flange Exclude counter flange Insulations Compressor acoustic enclosure Double thickness insulation Others High/Low pressure protection Anti-Freezing Flow switch Security grilles Security panels 2017 LG HVAC Solution 07

Specification Model Units UCAS020PBT1 UCAS040PBT1 UCAS020QBT1 UCAS040QBT1 UCAS020BBT1 UCAS020BBT1 Power supply - 380V-50HZ-3PH 400V-50HZ-3PH 220V-60HZ-3PH Cooling Capacity kw 65 130 65 130 67 134 Cooling Power Input kw 21.0 42.0 21.0 42.0 22.1 44.2 Cooling COP W/W 3.10 3.10 3.10 3.10 3.03 3.03 Running Current A 40.4 80.7 40.1 80.2 69.3 138.5 Cooler Type - Shell and tube heat exchanger Nozzle Connection Size DN 50 65 50 65 50 65 Water Flow m³/h 11.2 22.4 11.2 22.4 11.5 23.0 Pressure Drop kpa 45.3 45.3 45.3 45.3 45.3 45.3 Max.Water Pressure MPa 1.0 Compressor Type - Scroll Quantity of Compressor EA 2 4 2 4 2 4 Fan Type - Axial flow fan Quantity of Fan EA 2 4 2 4 2 4 Motor Power kw 2 4 2 4 2.7 5.4 Refrigerant Type - R410A Refrigerant Weight kg 14 28 14 28 14 28 Operating Weight kg 640 1,140 640 1,140 640 1,140 Shipping Weight kg 605 1,105 605 1,105 605 1,105 L mm 2,154 2,154 2,154 2,154 2,154 2,154 Dimension W mm 765 1,528 765 1,528 765 1528 H mm 2,354 2,354 2,354 2,354 2,354 2,354 Note: 1. Nominal condition(cooling): Water outlet temperature is 7ºC; Ambient temperature is 35ºC : Water flow rate 0.172 m³/h per kw 2. Fouling factor: 0.018m 2 ºC/kW 3. UCAS: Cooling only 08 2017 LG Air Cooled Scroll Constant Speed

Specification Model Units UCAS0209BT1 UCAS0409BT1 UCAS020DBT1 UCAS040DBT1 Power supply - 380V-60HZ-3PH 460V-60HZ-3PH Cooling Capacity kw 67 134 67 134 Cooling Power Input kw 22.1 44.2 22.1 44.2 Cooling COP W/W 3.03 3.03 3.03 3.03 Running Current A 42.7 85.3 34.6 69.2 Cooler Type - Shell and tube heat exchanger Nozzle Connection Size DN 50 65 50 65 Water Flow m³/h 11.5 23.0 11.5 23.0 Pressure Drop kpa 45.3 45.3 45.3 45.3 Max.Water Pressure MPa 1.0 Compressor Type - Scroll Quantity of Compressor EA 2 4 2 4 Fan Type - Axial flow fan Quantity of Fan EA 2 4 2 4 Motor Power kw 2.7 5.4 2.7 5.4 Refrigerant Type - R410A Refrigerant Weight kg 14 28 14 28 Operating Weight kg 640 1,140 640 1,140 Shipping Weight kg 605 1,105 605 1,105 L mm 2,154 2,154 2,154 2,154 Dimension W mm 765 1528 765 1,528 H mm 2,354 2,354 2,354 2,354 Note: 1. Nominal condition(cooling): Water outlet temperature is 7ºC; Ambient temperature is 35ºC : Water flow rate 0.172 m³/h per kw 2. Fouling factor: 0.018m 2 ºC/kW 3. UCAS: Cooling only 2017 LG HVAC Solution 09

Performance data Cooling performance correction factory Water outlet (ºC) Ambient Temperature (ºC) 25 30 35 40 45 48 5 0.98 0.96 0.94 0.90 0.85 0.74 7 1.04 1.02 1.00 0.96 0.88 0.79 9 1.08 1.06 1.05 1.02 0.97 0.86 11 1.14 1.12 1.09 1.06 1.03 0.92 13 1.20 1.19 1.16 1.13 1.09 0.98 15 1.26 1.24 1.20 1.18 1.14 1.04 Cooling input power correction factor Water outlet (ºC) Ambient Temperature (ºC) 25 30 35 40 45 48 5 0.80 0.85 0.96 1.01 1.13 1.28 7 0.83 0.89 1.00 1.03 1.16 1.29 9 0.85 0.91 1.01 1.05 1.19 1.30 11 0.86 0.92 1.01 1.09 1.20 1.31 13 0.89 0.93 1.02 1.12 1.21 1.32 15 0.90 0.94 1.03 1.14 1.23 1.33 010 2017 LG Air Cooled Scroll Constant Speed

Outline dimension 20RT Water outlet DN50 Water inlet DN50 512±50 687±50 2,154±50 765±10 Control box 2,354±50 2017 LG HVAC Solution 011

Outline dimension 40RT Water outlet DN65 Water inlet DN65 545±50 726±50 2,154±50 1,528±10 2,354±50 Control box 012 2017 LG Air Cooled Scroll Constant Speed

P&ID Cooling only Strainer TXV Air Other Cycle Compressor Cooler Water out Water in Accumulator 2017 LG HVAC Solution 013

Power wiring 20RT 014 2017 LG Air Cooled Scroll Constant Speed

Power wiring 40RT 2017 LG HVAC Solution 015

Installation of Chiller Selecting installation location Precaution when selecting the installation location Select the location that fits the following conditions to install the product. Location without direct heat from other heat source Location where noise of the chiller does not have negative impact to the neighbors Check the installation direction of the unit for the seasonal wind during the winter. Install the product so that the seasonal wind does not affect only one side of the product. Location not exposed to strong winds Location that can support the weight of the chiller Location with space for air flow and service Install the boundary sign, danger sign or barricade, if necessary. It is recommended to install a fence around chiller so that people or animals will not be able to access the area. When installing the product in areas with high humidity during the winter (Coast, seaside, lakeside), install the product where it is well ventilated and has plenty of exposure to sunlight. (Ex: Roof top with sunlight) If the product does not run during the winter, establish a plan to use the anti-freeze for the water supply. To prevent the condensed water from flowing, insulate the connected evaporator and pipe. To smoothly drain the condensed water, establish an inclined structure. Avoid installing the product at locations with the following conditions. - Location with corrosive gas such as acid or alkali gas. (Coolant can leak from the corroded pipes.) - Location with electromagnetic wave. ( It can cause the product to malfunction from defective parts.) - Location where flammable gas is generated or flows to prevent fire. - Location with high level of carbon fiber or dust - Special location exposed to oil, steam or emulsified gas Precaution for seasonal wind and winter season In areas with heavy snow or in extremely cold areas, sufficient planning is required for the product to run smoothly. Even in other areas, planning is required for seasonal wind during the winter season. Snow can go into the air discharge outlet of the condenser to freeze inside the chiller. Therefore install a large cover over the chiller for areas with heavy snowfall to prevent the snow from accumulating on the top. The chiller can freeze inside when the air inlet is clogged with snow. Therefore install the chiller on the base with at least twice the height of the average snow accumulation. (Default height of base: 300mm) If there is more than 100mm of snow on top of the chiller, always operate the unit after cleaning the snow. Do not install the product where there could be negative impact from snow in areas with heavy snowfall. Decide the installation direction of the chiller so that the side of the air heat exchanger does not face the direction of the snow. (Make the side of the air heat exchanger parallel to the direction of the snowfall.) Install a blocker with the height of the snow accumulation to avoid the snow around the chiller from being sucked into the coil side. (Prepare on site) If the wind comes in one direction of the unit where the seasonal wind is strong, there is a high chance that it can lead to issue with product capacity or imbalance of load. Therefore install the product so that it has consistent effect on the product cycle. If that is not possible, consider using a wind blocker or other devices. In areas with strong seasonal wind during the winter, apply the wind blocker hood, especially near the coastal area, without blocking the suction inlet of the chiller considering the direction of the wind. If the chiller is directly exposed to the seasonal wind during the winter, separately install a wind buffle. (Prepare on site) 016 2017 LG Air Cooled Scroll Constant Speed

Installation of Chiller Installation Guide at the seaside CAUTION When installing the chiller near the coast, make sure that it is not directly exposed to the coastal wind. When installing the chiller directly exposed to the coastal wind, separate anti-corrosive treatment must be done on the condenser of the chiller. * Selecting location of chiller Install the chiller where the building can block the coastal wind. Coastal wind Coastal wind Coastal wind Coastal wind If the product has to be installed inevitably facing the coast, install a wall around the outdoor unit. Wall The wall must be made of sufficiently strong material such as concrete to block the coastal wind and must be 1.5 times larger than the size of the product to protect the product 1,000mm apart. There must be 1,000mm of clearance between the wall and the chiller for smooth circulation of air. Coastal wind Install the product where the drainage is smooth. 2017 LG HVAC Solution 017

Installation of Chiller When installing the product, secure minimum space as shown below considering the service, suction and discharge of air flow. Consider the ventilation condition The air cooled chiller must be installed on open space or must have appropriate ventilation. When installed along the wall, there must be sufficient space for ventilation. Air (Unit: mm) Wall h 1 800 800+h 1 /2 Reference If the side of the chiller is near the wall and the height of the wall is less than 800mm, the distance between the wall and the chiller must be at least 800mm. If the side of the chiller is near the wall and the wall is 800mm or higher, space of half of h1 must additionally be secured on top of the 800mm for the distance between the wall and the chiller. (Unit: mm) Ceiling Air 5,000 W all 800 Reference If there is a ceiling on the top part of the chiller, the distance from the chiller to the ceiling must be 5,000mm or above. If the front or rear side of the chiller is close to the wall, the distance from the wall to the chiller must be 800mm or above. 018 2017 LG Air Cooled Scroll Constant Speed

Installation of Chiller Consider the service space There must be sufficient space for maintenance and repair work around the chiller. Service space C D Because this is the space where the water pipes are installed, make sure to secure sufficient space for future maintenance and repair work. Model Service space (Unit : mm) A B C D UCHS/UCAS20 800 800 800 800 UCHS/UCAS040 800 800 800 1,800 A B E Because this is the space where the water pipes are installed, make sure to secure sufficient space for future maintenance and repair work. Service space C D A B Service space (Unit : mm) Model A B C D E UCHS/UCAS20 800 800 800 800 600 UCHS/UCAS040 800 800 800 1,800 600 2017 LG HVAC Solution 019

Installation of Chiller Water management The water quality of the cold (hot) water is described as follows. The water quality must not fall below the following standard. If so, it can be judged to have risk within relatively short period of time. Reference Water Item Circulation type cold water Cold water PH(25 C) 6.5-8.0 6.5-8.0 Conduction rate (25 C μs/cm) 500 or below 200 or below Alkali level (PPM) 100 or below 50 or below Hardness (PPM) 100 or below 50 or below Chlorine ion (PPM) 100 or below 50 or below Lactic acid ion (PPM) 100 or below 50 or below Iron (PPM) 0.1 or below 0.3 or below Sulfur ion (PPM) Not detected Not detected Ammonium ion (PPM) 0.5 or below 0.2 or below Silica (PPM) 50 or below 30 or below Water pipe connection Connect the pipe so that the entrance of the cold (hot) water pipe is correct. Permitted water pressure resistance of cold water pipe system is 1MPa To prevent any external heat loss or dew drops forming during the cooling operation on the water pipe system, apply thermal insulation treatment. Install the air vent at the output end of the water pipe. (Air vent) If the thermometer is installed on the inlet/outlet of the cold/hot water pipe, the operating condition of the chiller can be checked. Always install the strainer (50 Mesh or above) that can be cleaned on the water pipe inlet side to filter any alien particles from entering the heat exchanger. Always install the strainer on the leveled pipe. (If sand, trash or rust gets mixed to the cold water system, it can cause product failure due to corrosion of metallic parts.) Install the on/off valve on the cold water inlet/outlet and bypass pipe on the pipe direction of the device side. - For the pipe system, it is recommended to install the bypass and clean the pipe before installing the product and during the annual pipe cleaning. - On/Off valve blocks the old water to the chiller that is not operating to reduce the power of the pump. Therefore select whether to install to fit the need of the site. Install the pressure gauge and thermometer on the inlet and outlet of the water pipe. Always install the flexible joint to reduce the vibration of the pipe and product. - Vibration of water pipe system is absorbed to prevent water leakage. For the cold water system part, make sure to use the component that complies with designed water pressure or above. Before supplying cold water to the chiller, clean inside the pipe system to remove any negative impact of particles to the product. 020 2017 LG Air Cooled Scroll Constant Speed

Installation of Chiller Installation mode A (Recommended method) Independent product installation Independent product installation T1 P1 T1 P1 T2 P2 LG supplied T2 P2 LG supplied Symbol Description Symbol Description Valve Temperature sensor (1: Inlet 2: Outlet) Strainer Pressure gauge (1: Inlet, 2: Outlet) Flexible joint Cold water pump 2017 LG HVAC Solution 021

Installation of Chiller Installation mode A (Recommended method) Independent product installation Independent product installation P2 T2 P2 T2 T1 P1 T1 P1 LG supplied LG supplied Symbol Description Symbol Description Valve Temperature sensor (1: Inlet 2: Outlet) Strainer Pressure gauge (1: Inlet, 2: Outlet) Flexible joint Cold water pump 022 2017 LG Air Cooled Scroll Constant Speed

Installation of Chiller CAUTION If the winter outdoor temperature is 0 C or below, take following measures to prevent the pipe from freezing as shown below. - If the outdoor temperature is low, the circulation water can freeze to damage the heat exchanger of the product when the product is stopped. If there is possibility of damage from low outdoor temperature, operate the pump to prevent the water from freezing. - If the product does not operate for a long period of time during the winter season, remove all the circulation water to prevent the damage of heat exchanger and pipe from freezing. - Add anti-freeze additive to prevent the circulation water from freezing during the winter season. Maintain the cold water flux within the designed flux to ensure appropriate chiller performance and reduce the tube damage from rusting, scaling and corrosion. LG is not responsible for any damage of chiller from poor water quality management or inappropriate processing water. Water pipe installation Appropriate pressure of pipe connection is flange connection of 1 MPa or below. Size of the water pipe must be the same as that of the product or larger. If there is risk of dew drops forming, always install the thermal insulation material on the outlet pipe of the cold water. To avoid connected water pipe from creeping from the load, use appropriate hook for support. To prevent the pipe connected part from freezing during the winter season, always install the drain valve at the most bottom of the pipe system. Cold water inlet pipe is located at the bottom and the outlet pipe is installed on the top. Water pump control If the cold water pump is not operating for a long period of time or if the anti-freeze liquid is not used as the cold water, the antifreeze pump control must be installed to prevent the pipe from freezing. The vibration of the pump can transfer to the pipe to cause noise indoors. As the plan to prevent the noise from spreading in the pump, install flexible joints at the inlet/outlet and use the anti-vibration amount for the pump support. 2017 LG HVAC Solution 023

Installation of Chiller Unit Combination Appropriate pressure of pipe connection is flange connection of 1 MPa or below. Size of the water pipe must be the same as that of the product or larger. If there is risk of dew drops forming, always install the thermal insulation material on the outlet pipe of the cold water. To avoid connected water pipe from creeping from the load, use appropriate hook for support. To prevent the pipe connected part from freezing during the winter season, always install the drain valve at the most bottom of the pipe system. Cold water inlet pipe is located at the bottom and the outlet pipe is installed on the top. When connecting several chillers, refer to the following for common pipe size. A1-D B1-D 12V GND A1 B1 A1-D B1-D 12V GND A1 B1 A1-D B1-D 12V GND A1 B1 Notice:30m communication wire provided by LG WARNING Electric work using special circuit based on the overall regulation and this manual must be done by qualified electrician. If the capacity of the power supply circuit is insufficient or if there is a defect, it can cause electric shock or fire. 1) Communication cable connection Refer to the above figure to connect the communication cable For the communication cable, distinguish A1 and B1 to connect to the slave units. 2) Use 2-line shield cable as the communication cable. 3) Separately install the communication and power cable of the chiller so that the communication cable is not affected by the electric noise generated from power cable. (Do not pass though the same electric pipe) 4) Unit combination is able to connect up to 12 units 024 2017 LG Air Cooled Scroll Constant Speed

Guide specification Contents Manufacturing specification Air cooled type scroll chiller product specification 1. Case 2. Compressor 3. Condenser 4. Thermal expansion valve 5. Evaporator 6. Control equipment 7. Ref. piping 8. Safety devices

Guide specification Manufacturing specification 1) Use the parts and material of GB standard products or equivalent products for those not specified in this specification, and all parts should be designed with structure that is easy for replacement, repair, and inspection. 2) If there is a problem in the chiller, or if there is an abnormal status of chilled water temperature and flow amount, etc., immediately stop the chiller operation and you have to be equipped with marking equipment or function that can easily identify these. 3) There should be a protection circuit to prevent chiller damage by blackout or frequent voltage variation. 4) Chiller should be able to operate silently without abnormal noise or abnormal vibration. 5) Chiller should be composed of the controller and the circuit possible for wired/wireless Start/Stop operation. 6) Easy combination should be possible with compact product design and module type design, and basic module insertion and assembly installation should be possible regardless of the volume. 7) It should be the structure possible for substitute operation even if compressor or some cycle parts fail and cooling operation should be possible during parts replacement, repair, or inspection. 8) The main power cable equivalent or above the specification presented in the product specification of each corresponding model should be used for the chiller, each communication line and power cable should use cable pipe for protection, and the cable pipe with the material that can block external noise according to the installation environment should be used. Air cooled scroll chiller product specification 1. Case 1) It should have the structure that is easy for disassembly and assembly for easy maintenance/repair. 2) It should have a beautiful exterior and be insulated in order to prevent dew condensation. 3) It should have the structure preventing vibration and abnormal noise. 4) It should have the structure that can be grounded. 2. Compressor 1) R410A refrigerant should be used, case shape should be sealed type, and format should be the combination of two scroll compressors. 2) Vibration prevention rubber should be used to prevent transfer of noise and vibration during operation. 3) The constant frequency of scroll compressor is 50Hz and 60Hz. 4) Alternating operation should be possible to have the uniform average operation time of the compressors. 3. Condenser 1) Condenser heat pipe should use purity 99.9 % or above Phosphorus Deoxidized Copper without joint, and it should have the structure with Al fin attached to increase the heating area. (Cross fin & Tube type) 2) Use wide louver fin for Al fin, and pipe extension should be carried out for efficient heat transfer. 3) Condenser air cooled type heat exchanger arrangement should be 3 rows 48 levels 15FPI. 4) The pressure endurance test for high pressure part refrigerant side should be carried out at 4.2 MPa or above (designed pressure 3.8 MPa), and there should be problems such as leakage or deformation. 5) The condensing coil that passed pressure endurance test should be vacuumed to completely remove moisture inside. 6) Use propeller type Fan, and it should be able to give sufficient wind amount required for condensing. Also, it should have sufficient strength for the number of rotations, and it should be operated silently through balance test. 7) Motor is constant frequency type that can increase efficiency. 8) Fan and motor should be connected directly. 4. Thermal expansion valve 1) It is the part that insulates and expands high pressure fluid refrigerant at condenser exit in low temperature, low pressure state, and during cooling operation, thermal expansion valve should be worked to adjust adequate refrigerant amount according to the evaporator load. 2) Based on data of various sensors installed in the chiller, microcomputer unit should be able to analyze operation status of the system and compressor to control the most adequate refrigerant amount linearly. 5. Evaporator 1) Evaporator should be shell & tube type heat exchanger, and the material should be carbon steel and copper tube. 2) There should be no water leakage, and the durability should be guaranteed. 3) It should have the structure that can connect to chilled water pipe. 4) Heat exchanger should be sensible heat exchange structure that the refrigerant and coolant are not mixed. 5) It should be a structure that each of coolant and refrigerant are flown into countercurrent structure heat exchanger and after heat is exchanged with each other through the thin valve inside heat exchanger, discharged outside heat exchanger. 6. Control equipment 1) It is the controller to operate overall system in optimal condition with the microcomputer unit installed in the chiller, and based on the measurement values including ambient 026 2017 LG Air Cooled Scroll Constant Speed

Guide specification temperature, fin temperature, discharged refrigerant gas temperature, and heat exchanger water side temperature, it should be able to control thermal expansion valve, compressor, etc. 2) There should be a function that can check all sensors connected to the chiller and various operation statuses. 3) It should be equipped with self-protection equipment and system protection function. 4) Module type control interface should be applied so that simple product control is possible in series installation, and relocation and re-installation of HMI controller should be possible without separate control equipment. 7. Refrigerant piping 1) Refrigerant pipe should be purity 99.9% or above phosphorus deoxidized copper without joint, and it should be piped for fluent refrigerant flow between each component. 2) Install strainer in the pipe to absorb moisture inside the pipe and to filter foreign objects. 8. Safety devices 1) Refrigerant pressure A. High & low pressure switch 2) Temperature A. compressor discharge temperature overheating detection (Sensor) B. Freeze and burst protection (Sensor) 3) Chilled water flow A. Chilled water flow switch 4) Voltage and current (Control logic) A. Revere phase detection and protection B. Compressor over-current protection C. Fan motor over-current protection 5) Fuse 2017 LG HVAC Solution 027

Ver. 201705 LG Electronics, Home appliance & Air solution company Two IFC, 10 Gukjegeumyung-ro, Yeongdeungpo-gu, Seoul, 150-945, Korea. www.lg.com www.lgeaircon.com For continual product development, LG reserves the right to change specifications or designs without notice. 2017 LG Electronics. Printed in Korea. May. 2017 Distributed by