Howler Go-Link Evacuation Alarm

Similar documents
HFR100. HFR Alarm Range HFR100. Fire Alarm. HFR600 Wireless Fire/First Aid Alert System. Fire Call Points. Fire Alarm. Features & benefits

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

Cygnus Wireless Alarm System


How to Build Visonic PowerMaster Wireless Alarm Systems

Smart Hub. Connecting people, connected care. What is it? Who is it for? How does it work?


SmartLINK Module Ei3000MRF for Mains Powered Multi-Sensor Fire / Smoke / Heat / CO Alarms - Ei3000 Series

Fire Alarm Control Panel. System Maintenance and Log Book

arm wire free solutions nurse call personal security fire alarms

SITE SECURITY THE SMARTER WAY TO PROTECT REMOTE AND TEMPORARY SITES, 24 HOURS A DAY.

PowerMaster Security Solutions

CALL FOR A FREE SURVEY

communicall connect solutions sheet What is Communicall Connect? Who is it for? What does it consist of?

Consultant Specification AGILE Wireless Fire Detection System

Conventional Fire System. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI User Manual

The EN54 Part 2 and 4 Fire System

Guided Learning Hours (GLH) 8 Invigilated Assessment Hours (IA) 2 Total Qualification Time (TQT) 10

Securing your safety

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

RadioLINK + Module EIB600MRF for Battery Powered Smoke / Heat Alarms EIB600 Series

RANGEOVERVIEW Integrated Emergency Lighting & Fire Detection System

PD6662:2010. A guide from Honeywell Security Group

Fire / CO Alarm Interface

USER MANUAL CEF AP28 CONTROL PANEL

Octalarm-T: the latest in future-proof industrial alarm diallers

Your Lifeline Vi+ home unit. Your MyAmie pendant

Zerio Plus EDA-R6000 Radio Combined Optical Smoke Detector and Sounder Installation Instructions

Overview. Wireless Overview QLD NSW VIC Fundamentals. Operation. Features.

Your specialist partner for total electrical compliance. Electrical Testing

FarmGuard External Wireless Security

DISABLED TOILET / EMERGENCY ASSISTANCE ALARMS

PRODUCT GUIDE & INFORMATION. Professional Fire & Carbon Monoxide Solutions

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

EURO 46 V10 User Manual

ACP10 & ACP50 Security Systems

PowerMaster. Expanding the Boundaries of Security. PowerG. Technology. with

Advanced FireAlarm Panel 1-4Loop

LOW FREQUENCY SOUNDER

Fire detection and alarm

Wireless Fire & Security Solutions. Fire Product Showcase

KFP-CF Series Operation Manual

Type 5 Certifications:

>WIRELESS> ALARM SYSTEM CR200

USER MANUAL & MAINTENANCE GUIDE OG OO

S.No. Description Unit (approx.) Unit price Total amount

Hardware for Sliding Doors & Folding Doors

CW9000 Wireless Fire System. Installation Manual

VISTA 48DLCT HONEYWELL SECURITY

Wireless Fire & Security Solutions. Fire Product Showcase

System 800 Addressable Fire Detection & Alarm System

Gas interlock system S & 100 CS

Best Practice Guide. Windows and Doors. Single-axis hinges to BS EN

Panic and Emergency Exit Devices

Fire Signalling. Signalling Solutions

Wireless security products

Cold chain monitoring technologies. Facility monitoring

Zerio Plus EDA-D6000 Radio Combined Heat Detector and Sounder Installation Instructions

A guide to the changes between BS 8418:2010 and BS 8418:2015

EMERGENCY ASSISTANCE ALARMS

DATAssure. Laboratory wireless alarm & monitoring system

Lifeline Vi Clever, not complicated

Europe s Leading Manufacturer of Fire + Carbon Monoxide Alarms

Product Guide MAN7030-2

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

Faster and smarter ways to protect what matters most. Our Next Generation portfolio

Total peace of mind. Services. Services. Total peace of mind

FIRE ALARMS EMERGENCY LIGHTS NURSE CALL ACCESS CONTROL GK FIRE & SECURITY LTD, UNIT 1 GREBE RD, PRIORSWOOD IND EST, TAUNTON, TA2 8PZ

Maintenance Guide EMS Security Group Ltd. All rights reserved. MK154 Iss5 18/11/15 AJM

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

The complete wirefree security alarm solution

Changes for EN50131 BS8243 PD6662

Logbook. Precept EN Fire Detection/Alarm Panel. & Precept EN Repeater

ACCESS SECURITY SYSTEMS (ELECTRONIC LOCKING) & ACCESSIBLE DOOR OPENING DEVICES ON MEANS OF ESCAPE

SITE SECURITY THE SMARTER WAY TO PROTECT REMOTE AND TEMPORARY SITES, 24 HOURS A DAY.

PANELS, KEYPADS & MODULES. Take Fire Protection to the Next Level Fire Products from DSC

Gas Safety Devices & Accessories

The EN54 Part 2 & 4 Fire System

REMOTELY OPERATED STENCH GAS RELEASE SYSTEM. Front Panel View Remote Activated Stench Gas Release System 240 Volt AC Supply

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

Control Panel User Guide

External Wireless Sounder

Sirène flash. Sirena con lampeggiante DP8406 DP8407 DP8408. Alarmsirene mit Blitzlampe. Siren and flashing. p. 19

Door Release Power Supply

General Routing Interface

WIRELESS ALARM SYSTEM CR200 >SMART GPRS INTRUSION DETECTION PLUG & PLAY FUNCTIONS SELF-LEARNING, SMART FEATURES TEXT ZONE NAMING

Security Alarm Systems

C-Stat 17-ZW User Instructions

SOUTH AFRICAN NATIONAL STANDARD

FireTek : Easier installation. Superior performance.

Alarm Controller Fire and CO

Touchpoint Plus. A whole new control experience

D3 Wireless temperature alarm & monitoring system family. tek-troniks

Real-Time Remote Monitoring System Utilizing New Electronic Personal Dosimeter

2) This manual covers Fire and General Alarm systems. The differences are described in the appropriate sections.

Using technology to safeguard your people and your property

A guide to the changes of Amendment 1 of BS

ESi CONTROLS BROCHURE LANDSCAPE V5.indd 1 14/08/ :31

AIRPORTS. CARECALLER PowerfulSecuritySolutionsForSeriousSecurityNeeds

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

Transcription:

Howler Go-Link Evacuation Alarm Go simple, GoLink In an age of sophistication, complexity and novelty, we sometimes lose sight of what we actually need, and ultimately what we actually want. When it comes to a fire warning system, there is one simple message you need to convey: GET OUT!, as clearly as possible. Creating a radio linked fire warning system which is simple to install, use and maintain is not a simple task. But that is what we have done with the Howler GoLink evacuation alarm. We ve focussed on what our clients have told us they need, and we have crafted it in the true Howler tradition: Reliable, Simple and Tough! When it comes to installing a temporary fire warning system, there is one simple objective: to get it done as quickly as possible. Get going - Get GoLink... When it comes to maintaining a temporary fire warning system, there is one simple objective: as little as possible. When it comes to the construction of the temporary fire warning system, there is one simple objective: as robust as possible.

User friendly wireless by Howler Howler GoLink product models shown: GLCP HOCP/GL HO1/GL/XS

Howler Go-Link: Key Benefits Easy-to-use control panel The Control Panel is designed to be easy to use, with self explanatory buttons for simple day to day operation. There are also a number of optional system settings available in the Set-up Mode, including Two Stage Alarm, Automatic Battery Test, Siren Time Out. Key events on the system are logged on an SD card so you can see what has been happening at any time. The panel is battery operated, but can be powered via a plug-in mains transformer. There are a number of output options from the panel to facilitate integration with ancillary equipment such as auto-diallers, CCTV systems and access control systems. Speedy set-up The system can be set up very quickly, with no requirement for specialist gear or laptop. Stations connect automatically with the Control Panel once they have been addressed. Continuous fault monitoring The panel constantly monitors connections between stations, and gives you warning if any station becomes disconnected, or if battery power runs low. This is of vital importance in a building which is constantly changing, and gives you peace of mind that the system is operating correctly. Very quick to install Saves time, saves money Continuous fault monitoring Know your alarms are connecting Wirelessly link 127 units No trailing wires Optional mains power adaptor for Control Panel Class 1 Radio Receiver Reliable connectivity

Mesh network connectivity GoLink stations work together, passing messages between units to maximise the range of the system. Up to 127 stations can be connected per channel on the system. Low maintenance features The panel has a Test Mode function, which enables you to conduct a complete walk test of the site, checking each Howler without returning to the panel to reset. However, the continuous fault monitoring reduces the need for a physical check. The batteries are off the shelf, recyclable alkaline batteries so that they are economical and quick to replace. They also pose low fire risk compared with lithium batteries. Anti-tamper features The Howlers are secured closed using a single security hex-key to prevent unauthorised access. The aerials are contained within the casing to prevent damage and interference. The Control Panel has an optional access code for use if it is installed in a non-secure area. HSE compliance The system meets the requirements of HSE guidance for Fire Safety on Construction Sites (HSG 168) and is CE marked in accordance with the R&TTE Directive and the requirements of EN 300 220-2, with a Class 1 Receiver. Outputs on panel For interfacing with other systems Functional Control Panel Very simple to set up and use 8 different channels For multiple building projects Hot Keys For quicker activation, testing and resetting Off-the-shelf Alkaline batteries Low ongoing maintenance costs

Howler Go-Link: Technical Data What do you need to comply with HSE requirements? The key guidance for fire warning systems on construction projects is set out in the HSE publication: Fire Safety on Construction Sites (HSG 168). The aim of any fire warning system is to ensure that people on site are alerted to make their escape before a fire becomes life-threatening. The essential requirements of the fire warning signal are that it is distinctive, clearly audible above any other noise and is recognised by all the people on site. On small open-air sites, a shout of fire may be adequate, and on simple sites with a limited number of rooms, a self-contained fire alarm may be needed. But: It is expected on the majority of sites that an inter-connecting (could be wired-in or wireless) system of call-points and sounders will be required to provide an effective fire warning system. The Howler GoLink system has been designed to meet these requirements, and furthermore the British Standards for permanently installed fire alarm systems (BS 5839-1 and BS EN54) have been used as best practice guidance, so that relevant requirements of these standards are met. Technical information System Overview Max no. of stations per channel Number of channels Switch options Panel outputs Detector options Howler volume Auto-dialler option 127 8 Call point Push on / Push off (IP65 switch) Push on / Twist off (IP65 switch) Push on / Key off (IP65 switch) 2 x Relays 9V Normally open contacts Heat and smoke detectors, wireless or hardwire linking 102dB at 1m GSM, battery-operated Auto-dialler. Dials up to 10 numbers in the event of fire Compliance The system carries a CE Mark in accordance with the requirements of the R&TTE Directive, the Low Voltage Directive and the EMC Directive. Independently tested and compliant with the following standards: EN 300 220-1 v2.4.1 Category 1 receiver EN 301 489-1 v1.9.2 EN 301 489-1 v1.6.1 EN 61000-6-3 EN 50130-4 EN 60950-1

Howler Go-Link: Ancillary Products There is a complete spectrum of ancillary items available to increase the capability of your GoLink system, including automatic detection, interface units and auto diallers. All Howler alarms are best mounted on a secure backboard, and our FirePost and CallPost range provide the perfect solution.

Howler monkey images and associated data Twycross Zoo. All information, logos and slogans contained within this brochure are the sole property of Howler UK and may not be reproduced in part or whole without written permission. The Howler logo and GoLink logos are registered trademarks of Howler UK. Howler UK is a trading name of DFP Global Ltd. E&OE Howler UK 08/15