Residual Current Devices

Similar documents
Cat. N. Cat. N (s) 1. DESCRIPTION - USE 3. OVERALL DIMENSIONS. Technology : 4. PREPARATION - CONNECTION 2. PRODUCT RANGE

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

3. RCCB (residual current operated circuit-breaker without integral overcurrent protection)

Operation and use. Functions and characteristics

Welcome to Hager Presentation

GE Industrial Solutions. Residential Electronic Circuit Interrupters

LAWSON FINAL DISTRIBUTION PRODUCTS RANGE

ES8. Candidate Code No. For Board Use Only. Result Date Int. Result Date Int

Operating Manual MS220KA and MSR220KA

40 CDe ENCLOSURES AND DISTRIBUTION BOARDS FOR SPECIFIC STANDARDS

GROUND FAULT PROTECTION PANELs. the power to protect GPD/GPFJ TYPES GPD, GPFJ, GPAD AND GPAFJ

Explosion Protected Panelboards D2Z Series

SensaGuard TM Integrated Latch Installation Instructions

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Moulded Case Circuit breakers

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

1.Application. 2.Main Technical Specifications B-10

INSPECTION AND TESTING OF ELECTRICAL INSTALLATIONS: RESIDUAL CURRENT DEVICES

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

ISOMETER isomed427p. Application Medical IT system in accordance with IEC , IEC , IEC and DIN VDE

QA(13) - Series Miniature Circuit Breakers

DPB52. True RMS 3-Phase, Multifunction monitoring relay. Benefits. Description

VAMP 120 & 121. Arc flash detection units. Product picture

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

Installation Datasheet

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24

Soft Starter AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

Data Bulletin. Determining the Cause of AFCI Tripping Class 760

User Information Sheet 008 : 2010

LC3000 Level Controller Installation and Maintenance Instructions

RSWT. Three phase AC pumps and ventilators soft starter. Benefits. Description

Power Supply Display Module PSDM. Installation and Operation Manual

SECTION AUTOMATIC TRANSFER SWITCHES

INSTRUCTION MANUAL (ATEX / IECEx)

Overload relays. General descriptions. Configuration of the front

ISOSCAN EDS460-DG. Insulation fault locator for DC IT systems with high system leakage capacitances

Ordering Key. Dielectric strength

Motor Controller AC Semiconductor Motor Controller Type RSBS23..A2V.2C24..

9/7/2010. Chapter , The McGraw-Hill Companies, Inc. AND BONDING. 2010, The McGraw-Hill Companies, Inc.

* Consult factory on conditions for approval acceptability

SECTION ISOLATED POWER SYSTEMS

Fault Current Monitoring in Electrical Installations

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

ISOMETER IR425. Insulation monitoring device for unearthed AC/DC control circuits (IT systems)

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Soft Starter Centrifugal Pump Soft Starter Series

HMN-D2 Insert Series

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

ELECTRONIC FLAME SUPERVISION MULTI-BURNER

5SM6 AFD unit preventive, proven, standard-compliant

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 12 September 2015 QUESTION AND ANSWER BOOKLET

SACE PR021/K SIGNALLING UNIT

Operating Manual MS220DA

Monitoring Relays. 3RN1 Thermistor Motor Protection. For PTC sensors. 7/120 Siemens LV 1 T 2008

Molded Case Circuit Breakers, Bulletin 140G

PART 4 ELECTRICAL STANDARDS

ISOMETER IRDH275BM-7 with coupling device AGH675-7 and AGH675-7MV15

Installation Instructions for W2H Series Signals

the next generation thermometer from the global leader

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

ELECTRICAL INSTALLER THEORY EXAMINATION. 14 November 2015 QUESTION AND ANSWER BOOKLET

Annunciator Relay MR 11 and MRE 11 MR 21 and MRE 21. Automation Equipment. Power Station Control Systems. Control Room Technology

Independent, accredited testing station Member laboratory of STL and LOVAG

LINETRAXX RCMA420. Residual current monitor for monitoring AC, DC and pulsed DC currents in TN and TT systems

LOVAG TEST INSTRUCTION IEC/EN

ISOSCAN EDS460/490 EDS461/491. Insulation fault locators with control and display function for EDS systems (insulation fault location systems)

The next generation thermometer from the global leader

Electrisaver User and Installation Instructions

Bulletin 140G Molded Case Circuit Breakers Product Selection 225 A, I-Frame

Series G Molded Case Circuit Breakers Amperes Technical Data and Specifications. NG-Frame. Product Description

RE-PR3-E-27 3-Phase Panel Mount 27kW

GM420. Digital Ground Continuity Relay For AC Systems. Technical Bulletin NAE /

CONTENTS AUTOMATIC TRANSFER SWITCHES

AUTO RESET ALARM RELEASE BOX MODEL AR-C INSTRUCTION MANUAL

PART GENERAL 1.01 SECTION INCLUDES

Microgrid Fault Protection Based on Symmetrical and Differential Current Components

Installation Instructions CS3 Three Phase Solid State Relay

Ground Fault Protection Improvement Study

MODEL GPT-130 SINGLE POINT HEAT TRACE CONTROL THERMOSTAT

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Installation Instructions

Flame Safeguards LFE10. Building Technologies HVAC Products

SECTION AUTOMATIC TRANSFER SWITCHES

ELECTRICAL SAFETY IN HEALTHCARE FACITILIES

Bulletin 1608N MiniDySC Dynamic Sag Corrector

DTA. Motor thermistor relay. Benefits. Description

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Smart Classroom Design

Bringing power to life. TECHNICAL BULLETIN RESIDUAL CURRENT DEVICE (RCD) SELECTION

Installation Instructions

275HVD NON-CONTACT, HIGH VOLTAGE DETECTOR DETECTOR DE ALTA TENSIÓN SIN CONTACTO

Pipe Freeze Protection Control SCFP-CO-F130 Installation and Operation Manual

INSTALLATION AND OPERATING INSTRUCTIONS R-3F2-LXX

Rules for Classification and Construction Additional Rules and Guidelines

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

ER 52 Electrician Regulations Answer Schedule. Question 1 Marks Reference Marking notes. (1 mark) EA 147M(c)(i) (1 mark) EA 147M(c)(ii)

Table of Contents. Protective Relays

Transcription:

Residual devices F200 Series UL 1053 Residual devices F200 Series Residual Current Devices Description The F200 Series residual devices offer a wide range of product for all of your fault protection needs. & C large offering for standard instantaneous and selective C and types. ll sizes up to 63 m with sensitivity thresholds up to 1 are offered in all possible pole configurations. BB RCDs carry many marks and approvals for the worldwide market. Features RCDs assure protection to equipment against leakage to earth. F200 F200C Type C mperage 16, 25, 40, 63, 80, 100, 16, 25, 40, 63, 80, 100, 125 126 Voltage 480Y/277 VC 480Y/277 VC Sensitivity 0.01-0.03 / 0.1-0.3-0.5 0.01-0.03 / 0.1-0.3-0.6 Low Voltage Products & Systems 83

Residual devices F200C F200 Series C Type C F202C No. of poles 2 residual m Catalog number 10 16 F202C-16/0.01 25 F202C-25/0.03 40 F202C-40/0.03 30 63 F202C-63/0.03 80 F202C-80/0.03 100 F202C-100/0.03 100 300 500 25 F202C-25/0.1 40 F202C-40/0.1 63 F202C-63/0.1 80 F202C-80/0.1 100 F202C-100/0.1 25 F202C-25/0.3 40 F202C-40/0.3 63 F202C-63/0.3 80 F202C-80/0.3 100 F202C-100/0.3 25 F202C-25/0.5 40 F202C-40/0.5 63 F202C-63/0.5 80 F202C-80/0.5 100 F202C-100/0.5 No. of poles 4 residual m 30 100 300 500 Catalog number 25 F204C-25/0.03 40 F204C-40/0.03 63 F204C-63/0.03 80 F204C-80/0.03 100 F204C-100/0.03 125 F204C-125/0.03 25 F204C-25/0.1 40 F204C-40/0.1 63 F204C-63/0.1 80 F204C-80/0.1 100 F204C-100/0.1 125 F204C-125/0.1 25 F204C-25/0.3 40 F204C-40/0.3 63 F204C-63/0.3 80 F204C-80/0.3 100 F204C-100/0.3 125 F204C-125/0.3 25 F204C-25/0.5 40 F204C-40/0.5 63 F204C-63/0.5 80 F204C-80/0.5 100 F204C-100/0.5 125 F204C-125/0.5 F204C Type C Suitable for alternating 2 & 4 poles 16-100 range Can be used as a main device providing ground fault protection against earth leakage for several MCB branch devices Technical data Technical data See page 15.90 F202C F204C 84 Low Voltage Products & Systems

F200 F200 Series Type Residual devices F202 No. of poles 2 residual m Catalog number 10 16 F202-16/0.01 25 F202-25/0.03 40 F202-40/0.03 30 63 F202-63/0.03 80 F202-80/0.03 100 F202-100/0.03 100 300 500 25 F202-25/0.1 40 F202-40/0.1 63 F202-63/0.1 80 F202-80/0.1 100 F202-100/0.1 25 F202-25/0.3 40 F202-40/0.3 63 F202-63/0.3 80 F202-80/0.3 100 F202-100/0.3 25 F202-25/0.5 40 F202-40/0.5 63 F202-63/0.5 80 F202-80/0.5 100 F202-100/0.5 No. of poles 4 residual m 30 100 300 500 Catalog number 25 F204-25/0.03 40 F204-40/0.03 63 F204-63/0.03 80 F204-80/0.03 100 F204-100/0.03 125 F204-125/0.03 25 F204-25/0.1 40 F204-40/0.1 63 F204-63/0.1 80 F204-80/0.1 100 F204-100/0.1 125 F204-125/0.1 25 F204-25/0.3 40 F204-40/0.3 63 F204-63/0.3 80 F204-80/0.3 100 F204-100/0.3 125 F204-125/0.3 25 F204-25/0.5 40 F204-40/0.5 63 F204-63/0.5 80 F204-80/0.5 100 F204-100/0.5 125 F204-125/0.5 F204 Type Suitable for alternating and pulsating 2 & 4 poles 16-100 range Can be used as a main device providing ground fault protection against earth leakage for several MCB branch devices Technical data Technical data See page 15.90 F202 F204 Low Voltage Products & Systems 85

Residual devices Technical data Functions and classification criteria RCDs Power loss of RCDs RCCBs F200 series Current in [] Power loss [W] 2P 4P 16 1.5-25 2.0 4.8 40 4.8 8.4 63 7.2 13.2 Performance in altitude of RCDs Up to the height of 2000 m, BB RCDs do not undergo any alterations in their rated performances. Over this height the properties of the atmosphere change in terms of composition, dielectric capacity, cooling capacity and pressure, therefore the performances of the RCDs undergo derating, which can basically be measured in terms of variations in significant parameters, such as the maximum operating voltage and the rated. F200 ltitude [m] 2000 3000 4000 service voltage Ue [V] 400 380 380 in In 0.96xln 0.93xln 86 Low Voltage Products & Systems

pplication guide Residual devices Residual devices Introduction Residual devices (RCD) have always played an important role in circuit protection by detecting leakage to ground for equipment in many installations. RCD s are used in unison with a circuit protective device in industrial applications in the United States. The following guide will give an insight to the construction, mechanical operation, and applications of RCD s. RCD Definitions Important definitions: Earth leakage Current that flows between line to line or line to earth. Residual The sum of the values of the electric s in all live conductors Fault Current that flows between line to line or line to earth. Earth fault When a conductive path is accidentally induced between a line and the earth RCD Definition RCD s provide ground fault protection to equipment by monitoring the leakage of to ground. n RCD will trip when a ground fault is detected in excess of the trip rating of the device. n RCD is designed to disconnect a circuit whenever it detects that the electrical is unbalanced between the phase conductor and the neutral conductor. n imbalance may be caused by phase leaking to ground. Difference between type and C Types of RCD s Type C Must be used for protection against C earth leakage. Test button Test wire Current transformer Position indicator Operator handle BB Residual Current Device Sense circuitry Solenoid Solenoid pin Terminals Type Must be used for protection against C and pulsating DC (rectified C) earth leakage. The type RCD must be installed in any circuit where the main supply is likely to be rectified. Some examples of applications where this would apply are motor speed controllers (drives) and power tools. Low Voltage Products & Systems 87

Residual devices pplication manual Mechanical operations RCD Mechanical operation Main Incoming Supply and Terminals The main incoming and the grounded neutrals are connected to the terminals. The operator handle places the RCD in the on and off position as the position indicator shows. Position indicator Operator handle Current Transformer and Sense Circuitry The transformer surrounds the neutral and L1 conductors. During normal operation, all of the being carried through the L1 conductor returns up through the neutral conductor. Therefore the s in the two conductors are equal and opposite. When a leakage to ground occurs it causes some of the to take a path to ground and creates an imbalance in the between the two conductors. This imbalance in induces a in the transformer (CT) which is then picked up by the sense circuitry. The sense circuitry then actuates the solenoid and the contacts are forced apart by a spring, terminating the electricity supply to the device. Terminals Terminals Sense circuitry Solenoid Test button and Test Wire When the test button is pressed it allows the correct operation of the device to be verified by passing a small through the test wire. This simulates a leakage to ground by creating an imbalance in the transformer (CT). Test button Current transformer Test wire Solenoid Once an imbalance has been detected by the CT, there is voltage induced on the CT. The voltage travels through the connected copper wires to the sense circuitry and the solenoid is actuated. The plunger at the bottom of the solenoid is then pushed out to trip the breaker. Sense circuitry Solenoid Solenoid pin Current transformer 88 Low Voltage Products & Systems

pplication manual Difference between RCD and MCB Residual devices Example of leakage to ground brasion in wire; small (m) leakage to ground Current flow L1 L1 1 X N N Current flow Neutral (N) return path is not equal to the in the hot (L1) path (leakage to ground); there is an imbalance between the L1 and N. Difference between RCD and MCB Miniature Circuit Breaker (MCB) miniature circuit breaker (MCB) is a device designed to isolate a circuit during an over event without the use of a fusible element. breaker is a resettable protective device that protects against two types of over situations; overload and short circuit. Residual Current Device (RCD) residual device (RCD) is a device designed to provide protection against voltage leakage to ground. RCD s are sensitive to a 30-300m. RCD s are mechanical devices that contain a CT and a solenoid. RCD s are designed to protect equipment, not wires against overload and short circuit situations. For this reason, an RCD should always be used in conjunction with an MCB in order to provide full protection from overload and leakage to ground. Ground Fault Interrupter (GFI) GFI Definition (NEC): device intended for the protection of personnel that functions to de-energize a circuit or portion thereof within an established period of time when a to ground exceeds the values established for a Class device. ground fault interrupter (GFI) is a device designed to measure the between the hot wire and neutral wire. Like the RCD, the GFI will open the closed contacts in order to protect against damage. GFI is sensitive to 5m and higher and is designed to protect people, not equipment. GFI is an electric device that contains a printed circuit board (PCB). GFI s have a pigtail wire at the end that carries a signal to the PCB that tells the contacts to open when a imbalance is detected between the two conductors. Low Voltage Products & Systems 89

Residual devices Technical data F200C, F200 Item F200C F200 pprovals: UL 1053 1053 CS - - VDE - - IEC - - Number of Poles: 2,4 2,4 Currents: 16,25,40,63,80,100,125 16,25,40,63,80,100,125 Operating Voltage: 480Y/277 VC 480Y/277 VC Production Category: IP20 IP20 Depth of Unit Per DIN 43880: 68mm/ 2.68 in. 68mm/ 2.68 in. Mounting Position: vertical, horizontal vertical, horizontal Standard Mounting: 35mm DIN rail 35mm DIN rail Main and Shunt Trip Terminals: Wire Size 18-4 WG/.82-21.2mm² 18-4 WG/.82-21.2mm² Torque 17.5 in-lbs./1.978 nm 17.5 in-lbs./1.978 nm Tool #2 Posidrive #2 Posidrive ccessory Terminals Wire Size 18-16 WG/.82-1.3mm² 18-16 WG/.82-1.3mm² Torque 4.5 in-lbs./.51nm 4.5 in-lbs./.51nm Tool # 1 Posidrive # 1 Posidrive Service Life at Load: No Load 20,000 operations No Load 20,000 operations Full Load 10,000 operations Full Load 10,000 operations Shock Resistance: 30g minimum of 2 impacts, 30g minimum of 2 impacts, shock duration of 13ms shock duration of 13ms Vibration Resistance: 5g, 20 cycles, 5 Hz, 150 Hz 5g, 20 cycles, 5 Hz, 150 Hz @ 0.8 ~ ln 90 Low Voltage Products & Systems