Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING

Similar documents
WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations.

Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations

Installation Instructions for W2H Series Signals

standards: standards:

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

Applications. Standard Materials

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

Installation and Maintenance Manual. Model 154XST Series Strobe Light for Use in Hazardous Conditions. français...page 21 español...

Flex-Tone Explosionproof Electronic Signals ETH655 & ETH855 SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. Installation

N2MVF Series Compact Fluorescent

EVLPF Series Compact Fluorescent

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps

INSTRUCTION & SERVICE MANUAL

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

INSTRUCTION & SERVICE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

LMV Series W Low Profile - Medium Base

Ex Mark:Ex d eb ⅡB T6 Gb

elevated ambient capability. in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems.

CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Enclosure 4X

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

MODELS SafeSite LED Linear, Class I Div. 1 2 & 4 Versions

Explosion Proof Emergency Fluorescent Light Combination - Dimmable Ballast - C1D1-2 T8 lamps - 4'

Explosion Proof 160 W Class 1 & 2 Fluorescent UV Light With 4 Lamps - Class 1 Division 1

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

4' 2 Lamp Fluorescent Light Fixture - Emergency Battery Backup - T8 Bulbs - Multi-voltage - CID2

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

OCH-SS series Direct Wired Units Indoor * and Outdoor Comfort Heaters

EVLED201 36W Led Luminaire. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 14.85

Certificate of Compliance

CXB Series SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Luminaire TO INSTALL: INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION

SUPPLEMENTAL INSTRUCTION SHEET POL S2 POINT OBSTRUCTION LIGHT SINGLE WITH ALARM

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

Static Pressure Alarm For Hazardous Location Fume Hoods

48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2

Circulation Heaters Selection Guidelines

Installation S19-324D1. Class I, Division 1, Groups C & D Explosion Proof. Emergency Signaling System

AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER IMPORTANT SAFETY INSTRUCTIONS

56W Hazardous Location LED Fixture - C1D2 - Stainless Steel - Dimmable - DALI Network

Standard Downrod for ceilings 8-10 feet high. Longer Downrod for ceilings 10 feet or higher

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

Certificate of Compliance

Table of Contents. What to Expect with. Mounting Options. Tools Needed

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Blades

CXH-A Forced-Air Heater

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

Homeland Security Light

Table of Contents What to Expect with. Mounting Options. Tools Needed. Downrod. Blades

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

PRO Series Energy Star Ceiling Fan Owner's Manual

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

50W Explosion Proof LED Light - C1D2, C2D1 - Replacement for 150W Metal Halide - Globe/Guard

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

*RENTAL* Class 1 Division Watt Incandescent Light - Explosion Proof - Wall Mount Volts

Hazardous Area LED Light -Class 1 Div 2 Groups A, B, C, D and Class 2 Div 2 F,G - 4' 4 lamp

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

UL Listed Available with Cl. I, Div. 2, Groups A, B, C, D rating

Explosion Resistant Unit Heater Owner s Manual This manual covers installation, maintenance, repair, and replacement parts.

LTFX Electric Tank Immersion Heaters Installation Instructions

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

Certificate of Compliance

Table of Contents. What to Expect with. Mounting Options. Tools Needed. Wall Control

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

KimberleyTM A Kichler Décor ceiling fan Designed to coordinate with a popular Kichler Lighting collection.

Certificate of Compliance

Technical Specification VFD

Class 1 Division 2 Hazardous Location Stack Light - Signal Traffic Light - Multiple Lamp Colors

Technical Manual for the Strobe - SM87 HXB

Important Safety Instructions. Important Safety Instructions

MODELS ASHP, ASHH, ASUP, and ASUH

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

STREAMLINE LP3 INCANDESCENT LIGHTS

Model AV1LED Audio-Visual LED Light Installation and Maintenance Manual

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

Table 500-3(d) Identification Numbers. Maximum Identification

DET-TRONICS SPECIFICATION DATA. Eagle Quantum EQ2200UVHT For Use With C7050B Continuous Duty High Temperature UV Flame Detector DESCRIPTION

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

The Signal Is Clear TM

3-6VFD Series Combination Flame and Explosion Proof Pilot Valve Enclosure

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

WATLOW ELECTRIC MFG CO. WATROD Duct Heater (module only) I& M Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.00

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Certificate of Compliance

Installation Instructions. Tersen. Ratio Canopy 1.5

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

Circulation Heaters Selection Guidelines

Table of Contents. What to Expect with. Tools Needed. Mounting Options. Preparation. Downrod. Maintenance.

INSTRUCTION MANUAL (ATEX / IECEx)

Transcription:

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations STANCHION 116EX-S CEILING 116EX-C 3/ CONDUIT ENTRIES PENDANT 116EX-P 3/ CONDUIT ENTRY 116EX-C (WALL MOUNTED) 3/ CONDUIT ENTRIES WALL 116EX-B 3" HUB 1 1/CONDUIT ENTRY 116 SERIES HOUSING AND GLOBE ASSEMBLY WITH GUARD Figure 1. Mounting Options Description The 116EXMLED Series AdaptaBeacon LED signaling appliances are intended for general utility signaling use. When assembled with an available mounting subassembly (116EX-P, 116EX-C, 116EX-S, or 116EX-C with 116EX-B) and in accordance with these instructions, the 116EXM LED visual signal is UL Listed as a Visual Signal Appliance. The 116EXMLED is UL and cul listed for use in Class I, Division 1, Groups C and D, Class I, Division 2, Groups A, B, C and D, Class II, Division 1, Groups E, F and G, Class II, Division 2, Groups F and G, and Class III Division 1 and 2 hazardous locations with operating temperature codes per Table 2. The beacons are UL and cul Listed for outdoor use with Type 3R, 4X, and Marine rated enclosures. The LED beacon flashes a 360-degree beam of light with 14 user selectable flash patterns. The LED beacons are available in pendant, bracket, ceiling, or stanchion mount models (Figure 1). Installation To reduce the risks of ignition of hazardous atmospheres and shock, do not apply power to the unit until installation has been completed and unit is tightly assembled and secured. Install this unit in accordance with the applicable requirements in the latest edition of the National Electrical Code and Canadian Electrical Code. 1. Mount using the following applicable method. a. Pendant Mount Models (Figure 2): Install the catalog number 116EX-P, pendant mounting module, to the main housing, tighten set-screw. Install explosion-proof hanger box (not supplied). Secure 3/ (19 mm) NPT threaded conduit (not supplied) to the box. Install the unit on the conduit. Ensure conduit engages at least PLAINVILLE, CT 800-336-4206 FAX 800-454-2363 5 full threads and then tighten the set-screw to secure the pendant mount module to the conduit. Make electrical connections in accordance with Figure XX. Refer to Table 2 for required supply wire temperature ratings. b. Ceiling Mount Models (Figure 3): Install the catalog number 116EX-C, ceiling/wall mounting module, using appropriate hardware (not supplied) suitable for the mounting surface. Make electrical connections in accordance with Figure 6. Refer to Table 2 for required supply wire temperature ratings. Install main housing to ceiling mount module. Tighten the set-screw to secure the 116EXMLED main housing to the ceiling mount module. c. Bracket Mount Models (Figure 4): Install the catalog number 116EX-C ceiling/wall mounting module using appropriate hardware (not supplied) for the mounting surface. Connect field earth ground wire to ground screw or earth ground via conduit system. Install the catalog number 116EX-B wall mounting elbow to the 116EXMLED main housing (feed the units wiring through the 116EX-B elbow). Tighten the set-screw to secure the 116EX-B elbow to the main housing. Make electrical connections in accordance with Figure 6. Refer to Table 2 for required supply wire temperature ratings. Install main housing and 116EX-B elbow subassembly to ceiling mount module. Tighten the set-screw to secure the 116EX-B elbow to the ceiling mount module. d. Stanchion Mount Models (Figure 5): Install the catalog number 116EX-S, stanchion mount module to the main housing and tighten set-screw. Mount the 116EX-S to the 1-1/ conduit, tighten set-screw. Ensure conduit is connected to the appropriate junction box. Install the unit on the conduit. Make electrical connections in accordance with Figure 6. Refer to Table 2 for required supply wire temperature ratings. P/N 3101456 ISSUE 1 2008

6 3/ (s) 12" 12 3/ 5/16" 1" 13" 13 3/ 7 1/ 7 1/ Figure 2. Detail of Pendant Mounting 2. Adjust flash rate. Beacons are factory defaulted to mode "Flash 3" (65 flashes per minute). a. Remove globe section; loosen the globe and ring assembly set screw. Insert a suitable tool into the notches in the globe and ring assembly and loosen the assembly by prying in a counterclockwise direction. Remove the ring and globe assembly. b. dipswitch (Figure 7) for desired flash rate. Refer to Table 3 for dipswitch settings. c. To replace, simply screw the globe assembly unit on until it seats firmly onto its gasket. Tighten the unit another 1/8 to 1/4 turn. Tighten the set-screw. atmospheres and shock, keep assembly tightly closed when circuits are energized. atmospheres and shock, disconnect from the supply and circuit and allow five (5) minutes for stored energy to dissipate before disassembling the unit. 3. Apply power to the unit and ensure proper function. Maintenance Figure 3. Detail of Ceiling Mounting atmospheres and shock, keep assembly tightly closed when circuits are energized. Disassemble the unit as follows (Figure 8): 1. Loosen the (3) guard screws and remove the guard. 2. Loosen the globe and ring assembly set screw. Insert a suitable tool into the notches in the globe and ring assembly and loosen the assembly by prying in a counterclockwise direction. Remove the ring and globe assembly. 3. Refer to Table 1 for the correct replacement catalog number and replace the necessary part. 4. To replace, simply screw the unit on until it seats firmly onto its gasket. Tighten the unit another 1/8 to 1/4 turn. Tighten the setscrew. 5. Reinstall the guard, where applicable, and secure using the three supplied screws. 6. After the unit is assembled, apply power and make sure the unit functions properly. P/N 3101456 ISSUE 1 PAGE 2

12 9/16" 13 1/ 9 7/16" 1" 6 3/ 1 1/ 12 3/ 13 1/2" 16 1/16" 5/16" 16 13/16" s 1 1/ Conduit Figure 4. Detail of Wall Bracket Mounting 25 Figure 5. Detail of Stanchion Mounting 2 1 3 1. Connect field earth ground wire to ground screw or earth ground via conduit system 2. Using wire nuts, connect unit s two white wires to incoming neutral (AC) or incoming (-) (DC) 3. Using wire nuts, connect unit s two black wires to incoming hot (AC) or incoming (+) (DC) Figure 6. Wiring (Bracket Mount Version Shown) 4 3 2 1 OFF S1 ON FLASH MODE Light Source Lens FLASH MODE S1 Globe & Guard Assembly PAGE 3 Figure 7. Detail of Dipswitch Location Figure 8. Disassembly of the 116EXMLED Series AdaptaBeacons P/N 3101456 ISSUE 1

Table 1. 116 Series AdaptaBeacons Catalog Electrical Conduit Flash LED Description Number Ratings Size Rate Replacement Housing Less 116EXMLED*-Y6 120-240V 50/60 Hz,.215A N/A ADJUSTABLE N/A 125-250V DC,.176A Ceiling/Wall 116EX-C N/A 3/ NPT N/A N/A Pendant 116EX-P N/A 3/ NPT N/A N/A Stanchion 116EX-S N/A 1 1/ NPT N/A N/A Wall Bracket 116EX-B N/A N/A N/A N/A Mounting Elbow *Letter in this position denotes color of the lens: A - amber, B - blue, W - clear, G - green, R - red Table 2. Ratings Operating Temperature Ambient Supply Wire Class I, Div. 2 Class I, Div. 1 & 2 Class II & III, Div. 1 Class II & III, Div. 2 Temp. Temp. Marking Groups A, B Groups C, D Groups E, F, G Group F, G 40 C 75 C T4 (135 C) T6 (85 C) T4A (120 C) T4A (120 C) 55 C 90 C T3C (160 C) T6 (85 C) T4 (135 C) T4 (135 C) 65 C 105 C T3C (160 C) T6 (85 C) T4 (135 C) T4 (135 C) Table 3. Flash Mode Selection S4 S3 S2 S1 DESCRIPTION PATTERN OFF OFF OFF OFF Steady Steady On OFF OFF OFF ON Multiburst 1 7 Bursts - Delay - Repeat OFF OFF ON OFF Multiburst 2 5 Bursts - Delay - Repeat OFF OFF ON ON Multiburst 3 10 Bursts - 3 Bursts - Repeat OFF ON OFF OFF Multiburst 4 8 Bursts - delay w/ slight illumination - Repeat OFF ON OFF ON Flash 1 65 FPM 10% Duty Cycle OFF ON ON OFF Flash 2 65 FPM 25% Duty Clyle OFF ON ON ON Flash 3 65 FPM 50% Duty Clyle ON OFF OFF OFF Flash 4 65 FPM 75% Duty Clyle ON OFF OFF ON Flash 5 80 FPM 10% Duty Clyle ON OFF ON OFF Flash 6 80 FPM 25% Duty Clyle ON OFF ON ON Flash 7 80 FPM 50% Duty Clyle ON ON OFF OFF Flash 8 80 FPM 75% Duty Clyle ON ON OFF ON Ramper Ramps up and then ramps down Contacting Edwards: Phone: (800) 336-4206 E-Mail: Website: P/N 3101456 ISSUE 1 techsupport@edwards-signals.com customerservice@edwards-signals.com http://www.edwardssignaling.com PAGE 4

P/N 3101456 OFFSET SPEC INSTALLATION INSTRUCTIONS FOR CATALOG SERIES 116EX ADAPTABEACONS FOR USE IN HAZARDOUS LOCA- TIONS (1) 11" X 17" SHEET PRINTED BOTH SIDES. FOLD THREE TIMES TO DIMENSIONS SHOWN ON DETAIL WITH PART NUMBER ON THE OUTSIDE. MATERIAL: STANDARD WHITE OFFSET STOCK CHARACTERS: TO BE BLACK ON WHITE BACKGROUND NOTE: MECHANICALS HAVE ALREADY BEEN REDUCED TO ACTUAL SIZE. RETURN MECHANICALS TO: TECHNICAL WRITING EDWARDS SIGNALING & SECURITY SYSTEMS PLAINVILLE, CT 06062 P/N 3100756 FOLD DETAIL REFERENCE ONLY ECN: 07-C1818 Issue: 1 File: 3101456 Approved by: GM