PILOT VALVE ENCLOSURES

Similar documents
PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Technical Specification VFD

3-6VFD Series Combination Flame and Explosion Proof Pilot Valve Enclosure

MultiGAS Monitoring System Hot/Wet IR Analyzer Technology. Clean Air Systems

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

standards: standards:

INSTRUCTION MANUAL (ATEX / IECEx)

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5100 EC Detection of toxic gases and vapors

INSTRUCTION & SERVICE MANUAL

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

OPTIBAR DP 7060 Supplementary Instructions

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Dräger Polytron 5720 IR Detection of carbon dioxide

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

UL HAZARDOUS LOCATIONS SERVICES

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Guide for hazardous areas

UltraCEM All Weather Continuous Emissions Monitoring System. Clean Air Systems

Dräger Polytron 5720 IR Toxic Gas Detection

Certification Supplement Manual

Annubar Flowmeter Series

Dräger Polytron 8720 IR Detection of carbon dioxide

Dräger Polytron 8700 IR Detection of flammable gases and vapors

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

UltraCEM-P Indoor Continuous Emissions Monitoring System. Clean Air Systems

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

INSTRUCTION & SERVICE MANUAL

Guide to Intrinsically Safe Portable Radios

MICROpeL 75 Combustible Gas Sensor Part Number: PM

Technical Specification

Guide to Hazardous Location Approvals: MICRO SWITCH Hazardous Area Limit Switches

Guide to Hazardous Location Approvals:

Operating Instructions

Dräger Polytron 5700 IR Detection of flammable gases and vapours

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

INSTRUCTION MANUAL (ATEX/IECEx/SIL2)

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Rosemount 3490 Series 4 20 ma + HART Compatible Controller

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Certificate of Compliance

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

FX5 Series Explosion-Proof Electric Air Heaters

4) Intrinsic Safety Certification

LTFX Electric Tank Immersion Heaters Installation Instructions

Dräger Polytron 8310 Stationary gas detector (DSIR)

Certificate of Compliance

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

Rosemount 3100 Series Ultrasonic Level Transmitters

User s Manual. AXF Series Magnetic Flowmeter Installation Manual ATEX and IECEx Explosion Proof Type IM 01E20A01-11EN IM 01E20A01-11EN.

Intrinsically Safe, NEMA 4, Type 4X, IP67 Loop-Powered Meter

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

Selecting a Safe Tank Gauging Product. Understanding Hazardous Area Definitions for Equipment Approvals

Dräger Polytron 8310 IR Detection of flammable gases and vapour

power HaZ-LOC MAGNET-SCHULTZ OF AMERICA Harness the of collaborative innovation Hazardous location Engineered for safety critical markets

Performance Data. curus Component Recognized; File No. E IP 20

Earth-Rite II PLUS Static Earthing System

Field Certification Certificate of Compliance

LOW PRESSURE Intrinsically Safe Transducer AST44LP

Both enclosures provide an IP 66 degree of ingress protection and are suitable for both indoor and outdoor installation.

Centro-Matic Automated Lubrication Systems System Controls

Trusted worldwide since 1989 INTRINSICALLY SAFE RANGE

Certificate of Compliance

EJBX. Ex d. AISI 316L stainless steel. - Zone 1, 2, 21, 22 - Group IIB+H2 - Stainless steel junction boxes - Choice of 13 sizes - IP 66 / 67

Overview of Hazardous Locations as They Relate to Solenoid Valves

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

Rosemount 752 FOUNDATION Fieldbus Remote Indicator

Certificate of Compliance

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

OPERATING AND INSTALLATION

Instruction Manual. CAT 100 & CAT 200 Continuous Analyzer Transmitter Addendum for Hazardous Area Applications. 3 rd Edition 05/2007

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

SUBMERSIBLE Flush Diaphragm Liquid Level Sensor AST4520

Certification Supplement Manual

Manual Power relay SR853

INSTRUCTIONS FOR SAFE OPERATIONS LM3000 EXPLOSION PROOF LASER DISTANCE METER

UL Topic III. Converting European EEx Certificates. Into. North American Division Certificates

RT FLOW RATE TOTALISER

EXPLOSION PROTECTION CERTIFICATE OF CONFORMITY Certificate No.: GYJ X

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

Certificate of Compliance

INTRINSICALLY SAFE LIGHTING RANGE

Explosion Proof Line Powered Telephone Ringer

Smart encoders & actuators

E2S Datasheet v10a. The IS-mA1 is suitable for all intrinsically safe signalling applications including fire, security and process control.

A guide to the use of electrical equipment in potentially explosive atmospheres To view this document in PDF format click here.

SmartLine. RMA803 SmartLine Remote Fieldbus Indicator Specification 34-ST-03-90, December Technical Information.

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

ELECTRICAL EX EQUIPMENT

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

C6097A,B Pressure Switches

Transcription:

PILOT VALVE ENCLOSURES PENTAIR ENVIRONMENTAL SYSTEMS

3-VFD COMBINATION FLAME AND DUST IGNITION PROOF ENCLOSURES Goyen pilot valve enclosures for hazardous locations are available in a combination of flame proof and dust ignition proof assemblies, where, and pilot valves are available. The 3-VFD can be supplied with combined international approvals: Canadian CSA/Underwriters Laboratory UL and European ATEX/ International IECEx. In addition, in Canada and Europe, Goyen offers enclosures that meet the requirements of both flame proof and explosion proof designs simultaneously. This has the advantage of simplifying assembly designs when using the Goyen enclosures. Construction Body: Diecast Aluminium AS313, LM2, 308 Ferrule: AISI 302 SS Armature: 30FR SS Seals: Nitrile Screws: AISI 302 SS Operation Recommended on time: 0 10 ms On time range: 0 00 ms Recommended time between pulses: 1 minute or more, if maximum on time is used. Pilot Performance Flow: 0.27 Kv/0.32 Cv Maximum Working Pressure: 80 kpa/12 psi Minimum Working Pressure: 0 kpa/0 psi Minimum Temperature: 0ºC/ 0ºF Maximum Temperature: 82ºC/ 0ºF Fluid Media: Air or inert gas Solenoid Performance VOLTAGE INRUSH CURRENT MA HOLD CURRENT MA POWER 220/20 0/0 Hz 18/13 10/9 23.1 V A 100/120 0/0 Hz 23/2 0/12 19.8 V A 873 873 20 W 2 V AC 1338 93 13 W 110 V DC 212 212 2 W Certification CSA/UL: NEC00 Div 1, NEC0 Zone 1 ATEX/IECEx: II Category 2G, II Category 2D RESTRICTIONS This product s hazardous areas certifications are valid only for product that has not been modified since leaving the factory. Modifications made to the enclosure such as the fitment of additional seals, the addition or removal of pilot valves and coils, changes in markings, or physical modifications made to the enclosure itself will invalidate the product certifications. Only activities described in Installation and Maintenance may be conducted without affecting the certification of the product. MAINTENANCE Annual maintenance of serviceable parts is recommended. Serviceable items are the pilot armature, armature spring, pilot valve body o-ring. The same model Goyen coil may also replace damaged coils. All other items are non-serviceable. Goyen recommend that appropriately qualified personnel conduct all maintenance activities. Certification of maintenance staff and facilities may be required under some certification schemes. Inappropriate service invalidates the product certifications. PRODUCT WARNING LABELS 3-VFD Series CSA/UL CAUTION: open circuit before removing cover WARNING: more than one live circuit. See diagram. ATEX/IECEx Warning do not open whilst energised, do not open when explosive atmosphere is present. Use cables rated at 13ºC when anti-condensation heater is installed. 02

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS GUIDE TO HAZARDOUS AREAS APPLICATION WITHIN DUST COLLECTORS Example zones around a dust collector The following examples assume that the particulate being collected is a combustible dust. te that the responsibility for correctly assessing the hazardous zones around the dust collection equipment remains with the plant operator. In the event of a filter breakage, dust will enter the clean side of the dust collector. The migration of dust may be in sufficient concentration to present a dust explosion risk. Where there are no dust monitors in place on the clean side of the dust collector, a broken bag condition may exist for more than 10 hours before rectification. Therefore the clean side is classed as Zone 1 (NEC0) or Zone 21 (Atex). Goyen supplies intrinsically safe and Atex 3G/D dust monitors to raise an alarm in the case of a filter break. In this case the clean air plenum is classified as Zone 2 if the system will be rectified within 10 hours. The area surrounding the dust collector housing may be classified as Zone 2. If there is adequate ventilation around the dust collector the Zone 2 classification may be eliminated. The area around the dust collection point is usually classified as Zone 1. COMPARING AREA CLASSIFICATION SCHEMES NORTH AMERICA NEC 00 Divisions NEC 0 & CEC Zones EUROPE (ATEX SCHEME) Gas Zones Dust Zones Equipment Category* 1 0 0 20 1 II 1 1 21 2 II 2 2 2 22 3 II Group** * Under the ATEX scheme equipment categories for use in gas environments are denoted by a G suffix, and equipment categories for dust environments are denoted by a D suffix. Examples: Equipment category 2G is suitable for use in ATEX zone 1 areas. Equipment category 2D is suitable for use in ATEX zone 21 areas. ** Only Group II zones are shown. Group I zones are relevant to mining applications only. Hazardous zone definitions DIVISION ZONE HAZARDOUS AREA CHARACTERISTIC 1 0 or 20 Hazardous condition is present continuously, for long periods, or frequently (more than 1000 hours per year) 1 or 21 Hazardous condition is likely to occur in normal operation occasionally (between 10 and 1000 hours per year) 2 2 or 22 Hazardous condition is unlikely to occur in normal operation, or infrequently and for short periods (less than 10 hours per year) 03

3-VFD SERIES COMBINATION FLAME AND EXPLOSION PROOF PILOT VALVE ENCLOSURE Diecast aluminium enclosure with explosion proof and flame proof (Ex-d) protection suitable for use in hazardous areas, available optionally with anticondensation heater. SUITABLE FOR NEC00 Division 1, NEC0 Zone 1 and ATEX/IECEx Zone 21 (II Cat 2G and 2D equipment) hazardous environments, for piloting Goyen diaphragm valves. SPARE PARTS K0383 Single armature kit. Includes, spring, armature, and o-ring. G07 DP Seal HOW TO ORDER 3-VFD 3-VFD PRODUCT CERTIFICATIONS WITH HEATER KIT FITTED WITHOUT HEATER KIT FITTED CSA LR2709 LR2709 Class I, Group D Class I, Group D Class II Groups E, F, G Class II Groups E, F, G Temp Code T2C Temp Code T UL Listed 823N Listed 823N Class I, Group D Class I, Group D Nema 7 Nema 7 Class II Groups E, F, G Class II Groups E, F, G Nema 9 Nema 9 Temp Code T3C Temp Code T3C IECex Ex d IIB T3 Gb Ex d IIB T Gb Ex tb IIIC T192 C Db IPX Ex tb IIIC T8 C Db IPX IECEx SIR 08.00X IECEx SIR 08.00X ATEX II 2 G D II 2 G D Ex d IIB T3 Gb Ex d IIB T Gb Ex tb IIIC T192 C Db IPX Ex tb IIIC T8 C Db IPX SIRA 02ATEX108X SIRA 02ATEX108X - Solenoid Type Approval Type QT2 solenoid order code, drop the K- Refer to Q Series Solenoid Product Specification C=CSA/UL, A=ATEX/IEC Ex Heater Type 0=none, =2VDC, =100/120VAC 7=20VAC Name Plate 1=Goyen, 0=none Thread Type 0=NPT/NPT, 1=RP/M, 3=NPT/M, = RP/G (Pilot Thread/Enclosure Conduit Thread) Number of Pilots Fitted, or 0

CSA/UL RATED ENCLOSURES PART NO. NO. OF VALVES THREAD SIZES GOYEN NAMEPLATE HEATER TYPE COIL VOLTAGE 3-VFD000C-330 3-VFD000C-331 3-VFD000C-33 3-VFD000C-330 3-VFD000C-331 3-VFD000C-33 3-VFD000C-330 3-VFD000C-331 3-VFD000C-33 3-VFD007C-330 3-VFD00C-331 3-VFD00C-33 3-VFD007C-330 3-VFD00C-331 3-VFD00C-33 3-VFD007C-330 3-VFD00C-331 3-VFD00C-33 GOYEN NAMEPLATE HEATER TYPE COIL VOLTAGE ATEX/IECEX RATED ENCLOSURES PART NO. NO. OF VALVES THREAD SIZES 3-VFD110A-331 3-VFD110A-330 3-VFD110A-332 2 V AC 3-VFD110A-33 110 V DC 3-VFD110A-33 3-VFD110A-331 3-VFD110A-33 110 V DC 3-VFD110A-33 3-VFD110A-331 3-VFD110A-330 3-VFD110A-33 3-VFD11A-33 3-VFD117A-330 3-VFD110A-332 2 V AC 3-VFD100A-331 3-VFD100A-33 3-VFD117A-330 3-VFD110A-332 2 VAC 3-VFD100A-330 220/20 VAC 3-VFD100A-330 220/20 VAC 3-VFD100A-331 100/120 VAC 3-VFD100A-33 2 VDC 3-VFD100A-330 220/20 VAC 3-VFD100A-331 100/120 VAC 3-VFD100A-33 3-VFD11A-331 3-VFD11A-33 3-VFD017A-330 RP 3/ NPT 0

3-VFD DIMENSIONS AND WEIGHTS [IN MM AND (INCHES)] WEIGHTS 3-VFD Series Mass = 2.21 Kg + 0.08 Kg per fitted pilot (.87 lbs + 0. lbs per fitted pilot) 0

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS INSTALLATION WARNING: Ensure that power is isolated from the system prior to installing or opening this product. Where a heater kit is installed, ensure that the heater has been de-energised for a minimum of minutes prior to opening the enclosure. Ensure that the enclosure is properly assembled with all flange screws fully tightened (minimum 10 Nm (7. ft.lbs)) prior to applying power in a hazardous area. Mounting Enclosures should be mounted in a horizontal position, where the pilot valves and solenoid assemblies are in the preferred vertical orientation. Threads Pilot valve inlet and exhaust outlets are offered in both 1 8 BSPP (Rp) and NPT. The enclosure base has one conduit entry with either M2 or ¾ NPT thread. Electrical connections Refer to diagram below. The included Goyen QT2 solenoids are provided with screw/spade terminals. These solenoids are neutrally linked at the factory for customer convenience. Pneumatic connections These pilot valves are connected to the dust collector reverse pulse jet valves using metric mm tubing (ID 0.17 ) or imperial ¼ tubing (ID 0.12 ) and maximum length of 1. m (.9 ft). ANTI-CONDENSATION HEATER ELEMENTS According to model specification numbers, the is enclosure type may be factory fitted with a heater element to assist in the prevention of condensation within the enclosure. HEATER RATINGS VOLTAGE WATTS 8 110/120 V AC 100 100 te that heater voltage matches solenoid voltages. HEATER INSTALLATION (1) Heater retaining clip (2) Heater element (3) Wiring terminal block () Thermostat element Heater terminal block connections 07

AUSTRALIA New South Wales Head Office 28 292 Milperra Rd Milperra NSW 221 Phone: +1 00 80 372 Fax: +1 1300 8 799 Queensland Phone: +1 00 80 372 Fax: +1 1300 8 799 South Australia Phone: +1 00 80 372 Fax: +1 1300 8 799 Victoria Phone: +1 00 80 372 Fax: +1 1300 8 799 Western Australia Phone: +1 00 80 372 Fax: +1 1300 8 799 Greenspan 21 Lawson Crescent Coffs Harbour NSW 20 Phone: +1 0 2 1 9830 Fax: +1 0 2 1 9831 70 Cleaver Terrace Belmont WA 10 Phone: +1 0 8 977 18 Fax: +1 0 8 979 727 22 Palmerin Street Warwick QLD 370 Phone: +1 7 0 88 Fax: +1 7 0 00 20 Lavarack Avenue Eagle Farm QLD 009 Phone: +1 7 38 7829 Fax: +1 7 320 191 EUROPE United Kingdom Pentair Environmental Systems Ltd Unit 3B Beechwood Chineham Business Park Basingstoke, Hampshire RG2 8WA United Kingdom Phone: + 12 817 800 Fax: + 12 332 70 Germany Pentair Umwelttechnik GmbH Im Petersfeld D-2 Altendiez Germany Phone: +9 32 9299-0 Fax: +9 32 9299-2 Italy Mecair s.r.l Via per Cinisello 97 2083 va Milanese Monza e Brianza, Italy Phone: +39 032 371 Fax: +39 032 37 279 USA Corporate Office Goyen Valve LLC 119 Airport Rd Lakewood, NJ 08701 732-3-7800 CEMS & Process Gas Monitoring Sales, Technical Support & Proposals Gary Cacciatore 71-38-7212 Gary.Cacciatore@Pentair.com Service & Support Don Ribbens 02-80-9 Don.Ribbens@Pentair.com ASIA China 21/F, Cloud 9 Plaza 11 West Yan An Road Shanghai 20002 China Phone: +8 21 239 8810 Fax: +8 21 3211 82 Malaysia 73-M Jalan Mega Mendung Kompleks Bandar, OUG, 8200 Kuala Lumpur Malaysia Phone: +0 3 7987 839 Fax: +0 3 7987 7839 Greenspan Blk 13 Kaki Bukit Road 1 Eunos Technolink #03-03 Singapore 1928 Singapore Phone: + 78 010 Fax: + 78 198 CLEANAIRSYSTEMS.COM Pilot Valves for Haz Locs Rev11 07/13 2013 Pentair Environmental Systems reserves the right to change product designs and specifications without notice.