Air cooler BC50 Blast freezer

Similar documents
Air cooler VNS Agricultural

Goedhart VNS. Air coolers for agricultural applications Cu/Al R404A - CO 2. engineering for a better world. GEA Heat Exchangers

AIR COOLERS FOR MEAT PROCESSING

AIR COOLERS FOR WIDE RANGE OF APPLICATIONS

Blow through unit coolers LEX. Standard coolers for cooling & freezing rooms

AIR COOLERS FOR WIDE RANGE OF APPLICATIONS

WORKING IN A DRAFT-FREE ENVIRONMENT

Goedhart air coolers. Goedhart Blast freezers (LLK.p) JUST IN TIME!!

Engineered efficiency - no matter where or what. KMe Coolers Fresh ideas from Searle. GEA Searle

The ideal cooler at a competitive price KELVION TEC COMMERCIAL AIR COOLER

Goedhart air coolers. Goedhart Blast freezers (PLK.s) FREEZE!!

HEATING & COOLING COIL PRODUCTS

Küba SG commercial

Küba SF blastfreezer. High-performance air cooler for blast chilling and shock freezing

Compact CUBIC. Air cooler GSF. Highly efficient compact air cooler Optimal for commercial refrigeration. HFCs 1 55 kw

LOW PROFILE EVAPORATORS

TEC Coolers. GEA Heat Exchangers. GEA Searle

GHF CXGHF GGHF. The all-in-one solution for commercial refrigeration! Güntner Info. High efficiency wall/ceiling-mounted air cooler. 0.

Compact SLIM. Air cooler GASC. Air coolers in a flat design with forced draught fans Optimal for commercial cooling. HFCs, CO 2 0.

Alfa Laval Arctigo ID

AIR COOLERS CONDENSERS DRY COOLERS SPECIAL PRODUCTS

GEA Searle Cooler and Condensing Unit Ranges Top-level engineering solutions. engineering for a better world. GEA Heat Exchangers

AIR COOLED CONDENSERS

NH 3. Dual Discharge Evaporator. Ammonia Industrial Applications 1-16 Tons MDAN

Güntner Info GHN. Vario Cubic for all refrigerants kw. Variable aircooler for industrial refrigerationw

New Industrial Dual Flow Unit Coolers

Industrial Unit Coolers

SPIRAL FREEZING & CHILLING SYSTEMS

Evaporators 60HZ version

Remote Air Cooled Condensers C2 Series

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Innovative Engineering. Catalogue. Heat Exchangers. Evaporators. EKL1. Extra low temperature applications (60 Hz)

Condensing Units CUS 15-60

Fincoil FMP and FMPG. Air coolers and liquid circulated air coolers

BLAST FREEZING ROOMS

WIBR SERIES. Unit Coolers - Technical Catalog Hunt St - Pryor, OK Fax

Compact VERTICAL FLAT. Compact. Condensers GCHC/GCVC for HFCs, NH 3

MS Series UNIT COOLERS. Technical Bulletin: MSUC_005_ Products that provide lasting solutions.

Technical data LA 60TUR+

A Series T 3. Unit Coolers - Technical Catalog. Product Benefits: Comdustrial TM Refrigeration. Adaptability- Durability- Serviceability-

Evaporator E4 Series. Innovative Refrigeration Solutions. Floor Mounted Blast Chiller/Freezer F - Series

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

TOPAZ ADIABATIC COOLER

CABERO PRODUCT CATALOGUE

Antarctic-Unit Cooler/Air Cooler

Launching of new SET-FREE Outdoor Units - RAS-FSXN1E Series (8-54HP)-

Air-Cooling Evaporators

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

QZHW Fan Coil Unit. Key features. Specifications

High Profile Evaporator

Kirby CO 2 Evaporators

Main technical datas:

Technical data LA 60TU

LOW PROFILE UNIT COOLER

Mechanical Systems Mechanical Systems

Technical data LA 28TBS

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

PRODUCT DATA COMFORT 5000 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 5300 m 3 /h

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

Process glycol chillers

Küba Blue Line Fresh Solutions.

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

PGDX Rectangular duct coolers with DX coil

TECHNICAL DATA. F.H. Biddle B.V. P. O. Box 15, NL-9288 ZG Kootstertille,The Netherlands. Tel: Fax:


PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

Split inverter air-to-water heat pump CERTIFIED BY CERTITA. option 30/35-40/45

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

EHH SERIES DRAW THROUGH FAN COILS CFM

Application guide FLATAIR - FLCK/FLHK. Providing indoor climate comfort

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Transformer oil coolers BETA & CETA

The ultimate in air handling units: directly and indirectly fired

THERMAL SOLUTIONS COAXIAL HEAT EXCHANGERS WKE, WKC

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

Compact and silent Scroll compressors All-season operation

Hi-Pres Cooling Products Catalogue. Product Catalogue

Technical data. Danfoss DHP-A

FRAL SRL via dell industria e dell artigianato, 22/C Carmignano di Brenta - PADOVA - ITALY

FAN COIL UNITS. The optimal solution for limited space

Microchannel Solutions by ThermoKey. Core Remote Condenser Liquid Cooler

DeCA DESIGN CRITERIA HANDBOOK PRODUCT REFRIGERATION SYSTEM

DERV / ERV DEHUMIDIFICATION & ENERGY RECOVERY V E N T I L A T O R U N I T S I N N O V AT I O N W I T H S T Y L E

LH and GH/GL Series UNIT COOLERS. Technical Bulletin. Products that provide lasting solutions.

WATER COOLED HEAT PUMP VERTICAL UNIT CONSOLE TYPE OR RECESSED

Technical data LA 9S-TU

HRV-IP. Ceiling Type Heat Pump Heat Recovery Unit

MACH N-407 Heat Pump Air-Cooled Chiller

The ultimate in air handling units: directly and indirectly fired

CoolTeg Plus XC40. AC-TXC Direct expansion Air-conditioning unit with integrated compressor

AQUASNAP JUNIOR 30RHV

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

Product Data. Features/Benefits. 38AH Commercial Air-Cooled Condensing Units 50/60 Hz. 20 to 130 Nominal Tons (63 to 390 Nominal kw)

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_002_ Products that provide lasting solutions.

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

Excellent performance with low operating costs, Energy saving and environmentally friendly

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

Transcription:

Air cooler BC50 Blast freezer Cu/Al - R404A GEA Heat Exchangers Goedhart

Goedhart Air Cooler Cu/Al BC50 Goedhart BC50 Goedhart BC50 blastfreezers The Goedhart BC50 blast freezers are a range of floor mounted aircoolers specially designed for quick freezing of food products. The Goedhart BC50 is a high-quality Goedhart aircooler with a lot of possible optional extras. The Goedhart BC50 air coolers are very suitable for the use in large scale kitchens (ready-to-serve meals). Besides this it can be used for quick freezing of bakery products, meat, fish, poultry, milk products and the production of ice cream. The working temperature is usually between -10ºC and -30ºC. The aircooler design is optimized for the use in confined spaces. Type description BC50 66657 Number of rows deep (6,7,8) Number of fans (2,4,6) Fin spacing (7,10,12 mm) Fan diameter in cm The process of quick freezing is very important to minimize the weight loss and conserving the qualities of the food product. The nutritional value is maintained, as well as the original taste. The fans on our Goedhart BC50 air coolers have standard 100 Pascal external pressure available to enable the quick freezing process. The Goedhart BC50 range is designed based on the most common used execution. Goedhart has a lot more possibilities to provide the optimum solution for its customers. Please have a look at the available non-standard executions or contact the sales department for more information. 2

Execution Tube Pitch : 50x50 mm square Fin Spacing : 7, 10 and 12 mm Material : Tubes : Copper 15 mm o d Fins : Goedhart Aluminum HT-Fins Standard refrigerant connections are positioned on the left hand side of the unit when looking with the direction of the airflow. Goedhart BC50 coil blocks have copper tubes mechanically expanded into fully collared aluminium fins, providing excellent thermal contact. All evaporator coils are pressure tested to 30 bars and supplied with a light overpressure charge. General range features Defrost systems For room temperatures where ice-build up can be expected and where the coil can not be defrosted by the room air, electric or hot gas defrost is necessary. Electrical defrost On request BC50 can be provided with electrical defrost. The stainless steel heating elements are fitted in the coil block within aluminium tubes, which forms a highly conductive medium between the heaters and the fins. In the drip tray heater elements are fitted to the underside of the aluminium inner tray. The elements are rated for 220/240 V and are connected (IP55) for 380/415 V (with neutral) supply. The heater elements in the coil block are removable from the bend side, whilst the tray heater elements can be removed once the outer tray has been removed. Casing Material Finishing Fixings Bends/header protection Defrost : galvanized sheet steel to form a robust construction. : natural : Stainless steel to prevent corrosion. : by end covers, easy removed for maintenance. : hot gas spiral or electric defrost elements will be fixed to the bottom side of the coil. L1 L2 L3 Aansluitingen bij1x230v en 3x L1 L2 L3 Aansluitingen bij 3x Mounting Goedhart BC50 must be handled with a crane. If only forklift truck is available, Goedhart must be informed when ordering the aircooler. 230V 230V 230V 220-240 V 200V 200V 3x380/420 Volt + N 3x380/420 Volt + N N N Standaard Licht ontdooivermogen Hot gas defrost The coil block is suited for hot gas defrost ( hot gas supply through the suction header). The drip tray can be provided with a copper hot gas spiral. This is enclosed in aluminium profiles that are rigidly secured to the under side of the aluminium inner drip tray. Maintenance Refer to our maintenance and installation manual. Capacities The capacities are based on R-404A direct expansion, DT1 (SC3, SC4) and a RH of 85% (frost layer 0 mm). See for more information page 5. Goedhart optimise the coil circuitry to suit the design condition. This provides the best performance for a given cooler in combination with application, refrigerant and capacity. Fans Manufacturer : Süd Electric Diameter : 650 mm Electrical suply : -50Hz-3 phase electrical supply. Connection : D (D / Y only on request) Protection class : IP66 Frequency regulation : only in combination with sinus filter Temperature : between -40 o C and +45 o C Thermo contact : PTO Sound power level (LwA) : 91 db(a) each fan (+/- 2 db(a)) When the air temperature is lower then -40 C, special fans are needed. These special fans have a longer delivery time. The technical data in the selection table are the same as on the motor name plates and is valid for an air temperature of +40 C. For air temperatures lower 1,20 then +40 o C, the current 1,15 amperage can be calculated by using the diagram 1,10 multiplication factor, suitable 1,05 thermal overloads can then be selected. 1,0 correction factor 20 10 0-10 -20-30 -40 Air temperature [ C] Sound data The mean sound pressure (LpA @ 3m ± 2 db (A)) each air cooler is a calculated indication value according to the EN13487 standard parallel pipe. Goedhart uses the fan manufacturer s sound power level (LwA) at the inlet side of the fan. Changes to or by the fan or the product, affect the sound, in these cases, consult the manufacturer for the new indication value. In critical sound requirements, we advise you to consult an expert. Optional extras Pump system / cooling mediums On demand the BC50 aircoolers can be designed for applications with pump systems or secondary refrigerants (glycol, water, etc.). Please contact Goedhart sales department for a quotation. Non-standard executions Goedhart is able to offer a lot of non-standard solutions. We can offer blastfreezers with higher available external pressure using axial fans. Also different lengths, heights and widths are possible. Tubes Stainless Steel (BR50) Execution ceiling mounted without legs Fins pre-coated with Goldlack Fins of Seawater resistant Aluminium (AlMg) Coating of the coilblock (tubes and fins) Various casing materials Various end plates materials Other fin spacings Staggered fin spacings Coupling between hotgas spiral and suctionheader Insulation discs Single phase fan motors 60 Hz fan motors Axial fans Adjustable feet Insulated driptray Fanheating Hinged fanplates Inspection doors / windows Water defrost In general: Do not hesitate to contact Goedhart for non-standard solutions! 3

BC50 Technical data =7 mm Type SC3 T in=-18 C DT1=7K -25/-18 DT1 (R404A) SC4 T in=-25 C DT1=6K -31/-25 Airvolume 100 Pa external pressure Surface Fans(Nominal values at 50Hz - 3x - T=40 C) Number Diameter Speed Power FLC Coilblock Electrical defrost Heavy Drip tray Total Sound pressure indication (LpA) at 3 m (+/- 2 db(a)) * BC50 kw kw m 3 /h m 2 mm min -1 Watt A kw kw kw db(a) 6.2.65.7 22,9 18,3 22332 172 2 650 1350 1500 2,80 12,30 2,16 14,46 71 8.2.65.7 27,4 22,0 21201 229 2 650 1350 1500 2,80 15,37 2,16 17,53 71 6.4.65.7 45,8 36,6 44622 343 4 650 1350 1500 2,80 23,26 3,34 26,60 74 7.4.65.7 50,6 40,6 43440 400 4 650 1350 1500 2,80 27,13 3,34 30,47 74 6.6.65.7 68,6 54,9 66912 514 6 650 1350 1500 2,80 35,60 4,80 40,40 76 8.6.65.7 82,0 66,0 63503 685 6 650 1350 1500 2,80 46,99 4,80 51,79 76 * = Sound pressure indication (LpA) at 3 m distance each air cooler (+/- 2 db(a)), free field conditions, according EN13487 =10 mm Type SC3 T in=-18 C DT1=7K -25/-18 DT1 (R404A) SC4 T in=-25 C DT1=6K -31/-25 Airvolume 100 Pa external pressure Surface Fans(Nominal values at 50Hz - 3x - T=40 C) Number Diameter Speed Power FLC Coilblock Electrical defrost Heavy Drip tray Total Sound pressure indication (LpA) at 3 m (+/- 2 db(a)) * BC50 kw kw m 3 /h m 2 mm min -1 Watt A kw kw kw db(a) 6.2.65.10 19,5 15,7 24007 124 2 650 1350 1500 2,80 12,30 2,16 14,46 71 6.4.65.10 38,9 31,3 47981 247 4 650 1350 1500 2,80 23,26 3,34 26,60 74 6.6.65.10 58,3 46,9 71954 370 6 650 1350 1500 2,80 35,60 4,80 40,40 76 * = Sound pressure indication (LpA) at 3 m distance each air cooler (+/- 2 db(a)), free field conditions, according EN13487 =12 mm Type SC3 T in=-18 C DT1=7K -25/-18 DT1 (R404A) SC4 T in=-25 C DT1=6K -31/-25 Airvolume 100 Pa external pressure Surface Fans(Nominal values at 50Hz - 3x - T=40 C) Number Diameter Speed Power FLC Coilblock Electrical defrost Heavy Drip tray Total Sound pressure indication (LpA) at 3 m (+/- 2 db(a)) * BC50 kw kw m 3 /h m 2 mm min -1 Watt A kw kw kw db(a) 6.2.65.12 18,4 14,8 24677 105 2 650 1350 1500 2,80 12,30 2,16 14,46 71 6.4.65.12 36,6 29,5 49327 209 4 650 1350 1500 2,80 23,26 3,34 26,60 74 6.6.65.12 55,0 44,2 73976 314 6 650 1350 1500 2,80 35,60 4,80 40,40 76 * = Sound pressure indication (LpA) at 3 m distance each air cooler (+/- 2 db(a)), free field conditions, according EN13487 4

BC50 Technical data B C 41 29 240 E 18 60 60 180 H C D 1 1/4 BSP-M outs D1 L D Type Dimensions Internal volume Weight (empty) L B H C E D D1 7 mm 10 mm 12 mm BC50 mm mm mm mm mm mm mm dm 3 kg kg kg 6.2.65. 1456 993 1950 800 1036 728 43 310 290 290 8.2.65. 1456 1093 1950 900 1036 728 57 360 6.4.65. 2456 993 1950 800 2036 614 1228 85 515 475 470 7.4.65. 2456 1093 1950 850 2036 614 1228 99 560 6.6.65. 3456 993 1950 800 3036 576 2x1152 127 710 655 650 8.6.65. 3456 1093 1950 900 3036 576 2x1152 169 840 Correction factors DT1 (= air-on temperature) Capacities: DT1: are based on R-404A direct expansion and DT1. the difference between air-on temperature and the evaporation temperature of the cooler. The evaporation temperature is the saturate temperature corresponding to the pressure at the suction outlet of the cooler. The nominal capacities: (SC3) t O =-25 C and DT1=7K (SC4) t O =-31 C and DT1=6K Correction factors for various air-on temperatures and temperature differences (DT1) are as indicated in the table below. The requested capacity must be multiplied by a correction factor from the table. so that a cooler with the resulting nominal capacity can be chosen from the selection tables. Q nominal = factor x Q requested DT1 Evaporation temperature ( C) SC3 (T o =-25 C DT1=7K) DT1 Evaporation temperature ( C) SC4 (T o =-31 C DT1=6K) K -21-22 -23-24 -25-26 -27-28 -29-30 6 1.20 1.20 1.21 1.21 1.22 1.22 1.23 1.23 1.24 1.24 7 0.99 0.99 0.99 1.00 1.00 1.00 1.01 1.01 1.02 1.02 8 0.83 0.84 0.84 0.84 0.85 0.85 0.85 0.85 0.86 0.86 9 0.72 0.72 0.72 0.73 0.73 0.73 0.73 0.74 0.74 0.74 10 0.63 0.63 0.63 0.64 0.64 0.64 0.64 0.65 0.65 0.65 11 0.56 0.56 0.56 0.57 0.57 0.57 0.58 0.58 0.58 0.58 12 0.50 0.51 0.51 0.51 0.51 0.51 0.52 0.52 0.52 0.52 K -31-32 -33-34 -35 6 1.00 1.01 1.01 1.02 1.03 7 0.82 0.83 0.84 0.84 0.84 8 0.70 0.69 0.69 0.69 0.69 9 0.58 0.59 0.59 0.59 0.60 10 0.51 0.51 0.51 0.51 0.52 11 0.45 0.45 0.46 0.46 0.46 12 0.41 0.41 0.41 0.41 0.41 5

Goedhart product information Goedhart Blast freezer overview 6

Goedhart general information Goedhart air coolers for every application For Contractors and Original Equipment Manufacturers (OEM) related to the industrial refrigeration industry, GEA Goedhart B.V. offers an unlimited range of air coolers and air cooled condensers in several configurations. Depending on the application, the optimum configuration will be selected in close cooperation with our customers. Configurations The following material combinations are available in various tube pitches and various fin spacing: Tube material Tube configuration Fin material Copper (Cu) 38x33, 50x50, 60x60 Aluminium (Al) Stainless steel (Stst) 38x33, 50x50, 60x60 Aluminium (Al) Stainless steel (Stst) 50x50, 60x60 Stainless steel (Stst) Aluminium (Al) 60x60 Aluminium (Al) Hot dipped galvanized steel (FeZn) 60x60, 75x75 Hot dipped galvanized steel (FeZn) Options on aluminium fins Goldlack coated fins Seawater resistant aluminium fins (AlMg) Applications Cooling Cold stores / Distribution centres Food processing rooms Fruit storage Banana ripening storage Greenhouse conditioning Freezing Cold stores / Distribution centres Tunnel / spiral freezers Slaughter houses Automotive testing rooms Ski domes Pressure Equipment Directive (P.E.D.) All aircoolers produced by Goedhart comply with the Pressure Equipment Directive 97/23/ EC. PED certificates can be downloaded from www.goedhart.nl. 7

GEA Refrigeration GEA Goedhart B.V. Nijverheidsweg 6, 4695 RC Sint Maartensdijk the Netherlands Phone +31 (0)166 665 665, Fax+31 (0)166 663 698 www.goedhart.nl info.goedhart.nl@geagroup.com GEA Refrigeration GEA Goedhart s.r.o. Kostomlátecká 180, 288 26 Nymburk Czech Republic Phone +420 (0)325 819 951, Fax+420 (0)325 519 952 www.goedhart.cz goedhart.cz@geagroup.com 03.03.2.003.dok 2010-01 / Subject to modification All offeres, contracts, deliveries and other legal relations from GEA Goedhart B.V. are subject to the latest version of our general sales and delivery conditions as filed at the Chamber of Commerce in Middelburg - The Netherlands Applicability of the general conditions put forward by any buyer is rejected explicitly by GEA Goedhart B.V.