[U] Serie MHB / MHA Manual de Ingeniería

Similar documents
MANUAL DE INGENIERIA. Part 1 General Information... 1 Part 2 Indoor Units... 6 Part 3 Outdoor Units... 30

[U] Serie MOV. Manual de Ingeniería

UCV CONDENSING UNITS SPECIFICATIONS 1. Specifications

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Part 1 General Information... 1 Part 2 Indoor Units... 7 Part 3 Outdoor Units Part 4 Installation Part 5 Control...

Service Manual. Multi Split Type Heat Pump Air Conditioners. Applied to: HS-9U2IM_HOS-18U2IM HS-9U11IM_HS-12U11IM_HOS-21U11IM

Four-way Cassette Type

Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type. R410A50Hz Universal Outdoor Series Technical Manual LCAC/2016.

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

Floor-Standing Type(E Series)

High static Pressure Duct Type Air-conditioner

Ceiling & Floor type Unit

R410A50Hz Universal Outdoor Series Technical Manual

DC Inverter Multi-split System Technical Manual - 50Hz/R410a

Service manual. MIV V4+ Mini

DC Inverter Multi-split System Technical Manual - 50Hz/R410a

R410A50Hz Universal Outdoor Series Technical Manual

Technical Manual. R410A 50Hz Universal Outdoor Series Inverter type Version. R410A50Hz Universal Outdoor Series Technical Manual LCAC/1.

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Multi Inverter Air Conditioning Condensing Units - Summary

MODEL: ACWD CEILING CONCEALED Chilled Water Fan Coils Unit

Contents. Part 1 General Information...2 Part 2 Outdoor units...7 Part 3 Installation...63 Part 4 Controller...79

Floor-Standing Type(S2 Series)

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

MODEL: CCT 301 INV CCT 501 INV CCT 70 INV-S CCT 100 INV-S CCT 140 INV-S CCT 170 INV-S

1. Features Specification Dimensions Refrigeration cycle diagram Operation limits

Submittal Sheet AIR-CON MULTI-SPLIT II. High-Wall Cassette Duct Floor and Ceiling AMTCM4H4R18

Air Conditioner SVC MANUAL(Exploded View)

Miraco MISR REFRIGERATION & AIR CONDITIONING MFG. CO.

Ceiling type. Contents MMC-AP 1H2UL MMC-AP0181H2UL MMC-AP0361H2UL MMC-AP0421H2UL

Wall Mounted Split Systems

Engineering Data Book

1. MODELS LIST NOMENCLATURE FEATURES PRODUCT DATA FAN CHARACTERISTICS CLEARANCE DATA...

Product Data. Features/Benefits. 30RQ Air-cooled Modular Chiller R22 & R410A & R407C

SERVICE MANUAL CONDENSING UNIT ASE-18AH, ASE-24AH, ASE-36AH, ASE-48AH, ASE-60AH

TECHNICAL & SERVICE MANUAL

Air Conditioners. Technical Data RZQG-L

Engineering Data Book

Service Manual. Compact Series REFRIGERANT R407C R22 COOLING ONLY HEAT PUMP. Indoor Units Outdoor Units IOD 7 CON 7 IOD 9 CON 9 IOD 12 CON 12

Highly Efficient,Powerful Heating and Cooling.

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

R410 a. Air Conditioners. Residential and commercial. R410 a

Amendment Sheet. Nomenclature M 5 AC V 100 C R - F X AA. Code : M5ACV Date : Superceded : M5ACV

Cassette SERVICE MANUAL. YKHC 18 to 48 YKHC 18 YKHC 24 YKHC 30 YKHC 36 YKHC 48 SM-YKHC-18-48GB 03-07

Engineering Data Book

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

Window Y9USC/E 09 / 12 / 18 B5R

Digital Inverter 4 series 8 & 10HP

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

SKM. Air Conditioners TROPICAL

TECHNICAL DATA & SERVICE MANUAL

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

Engineering Data Book

Ventilation. Technical Data. Outdoor air processing unit, ventilation and air processing EEDEN FXMQ-MF

Engineering Data Book

4-Way Cassette type. Contents MMU-AP 2H2UL

Horizontal Water Source Heat Pumps And Cooling Only Unit

Part 1 General Information... 1 Part 2 Outdoor Unit... 4 Part 3 Installation... 45

ROOFTOP PACKAGE (GC201105) TECHNICAL SALES GUIDE-50&60Hz CAPACITY RANGE:3~30TON SUPER HIGH AMBIENT OPERATION TO 55

Concealed Ducted Split Series R-407C MBH

SUBMITTAL M4MCW1509A-SUB-1C. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Submittal Data Sheet

technical data air conditioning systems RZQ-B Pair/Twin/Triple/Double Twin Application, Inverter Controlled Unit Split Sky Air

PAJ3. Product Specifications

AIR HANDLER UNIT R410A 60HZ ON-OFF CONTROL

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH

Air to Air Heat Exchanger

January Engineering Data RXSQ24-60TAVJU. Heat Pump 208/230V / 60 Hz / 1 ph. Presales Manual DAIKIN NORTH AMERICA LLC

TECHNICAL DATA & SERVICE MANUAL

CASSETTE, FLOOR&CEILING, DUCT UNITS OUTDOOR UNITS

Midea Precision Air Conditioner Technical Manual (Down delivery series)

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

Service Manual. Alpha Series REFRIGERANT R410A COOLING ONLY HEAT PUMP. Alpha 9 Alpha 17 DF. ONG3-17 (Alpha)

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr

1. Model Names of Indoor/Outdoor Units. 2. External Appearance. 1.2 Model Names of Units with Cooling and heating: 2.1 Indoor Units. 2.

TECHNICAL GUIDE MODELS: DCPM/DHPM PREMIUM SERIES DUCTLESS SINGLE-SPLIT AIR CONDITIONERS AND HEAT PUMPS 22 SEER 1 PHASE 3/4 THRU 3 NOMINAL TONS

HGF / HHF Series REFRIGERANT. SM HGFHHF 1-A.1 GB March Version:2

FAN COIL USER MANUAL TC18C2DWB1 TC24C2DWB1 TC37C2DWB1 TC48C2DWB1 TC60C2DWB Innovair Corporation. All Rights Reserved.

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Thank you for selecting LENNOX air conditioners.

Service Manual. Air Conditional

Alpha Aire. Dedicated Outdoor Air System, VAV, Air-Source Heat Pump with Energy Recovery. Engineering Guide Effective February 2018

EER PACKAGE AIR CONDITIONER, 6.9 to 14.4 kw, 2 4 TONS 3 Phase, Standard CFM / Ls EER

SERVICE MANUAL UNI ON/OFF ASC-60A

technical data air conditioning systems RZQ-B9V3B_RZQ-B8W1B Pair, Twin, Triple, Double Twin, Application, Inverter Controlled Split Sky Air

LOW STATIC HYDRONIC DUCTED UNIT

Aqua Mini Full DC Inverter Unitary Chiller 50Hz. Content

Air Conditioning Technical Data RZAG-MV1

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT


MINI CHILLER INVERTER H4 Service manual MUENR-H4 (5, 7, 10, 12, 14, 16 kw)

HSP Ducted Series REFRIGERANT. SM HSP Ducted 1-A.1 GB DECEMBER Version:1

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

Blanc ON-OFF Series. Service Manual 2016

Fan Coil Unit 1. BOSCH Climate Fan Coil Unit

Mobile Type Air Conditioner

Wall Mounted Air Conditioner SVC MANUAL(Exploded View)

Transcription:

[U] Serie MHB / MHA Evaporadoras Soplladoras de Alltta Presiión Esttáttiica 6..3,, 8 y 12..5 Ton Manual de Ingeniería. - 1 -

General Information_MHB 1. Model Names of Indoor/Outdoor Units 2. External Appearance - 2 -

1. Model Names of Indoor/Outdoor Units 1.1 Model Names of Indoor Units: Model Refrigerant Capacity (Btu/h) Power Supply MHB-76CR R22 76000 220-240V~1ph~50Hz MHB-76HR R22 76000 220-240V~1ph~50Hz MHB-96CR R22 96000 220-240V~1ph~50Hz MHB-96HR R22 96000 220-240V~1ph~50Hz MHA-150HR R22 150000 220-240V~1ph~50Hz 1.2 Model Names of Outdoor Units: Model Refrigerant Capacity (Btu/h) Power Supply MOV-76C R22 76000 380-415V~3ph~50Hz MOV-76H R22 76000 380-415V~3ph~50Hz MOV-96C R22 96000 380-415V~3ph~50Hz MOV-96H R22 96000 380-415V~3ph~50Hz MOV-150H R22 150000 380-415V~3ph~50Hz - 3 -

2. External Appearance 2.1 Indoor Units MHB-76CR MHB-76HR MHB-96CR MHB-96HR MHA-150HR - 4 -

2.2 Outdoor Unit MOV-76C MOV-76H MOV-96C MOV-96H MOV-150H - 5 -

High Static Pressure Duct Type_MHB 1. Features.... 2. Specifications.. 3. Dimensions.. 4. Service Space.. 5. Piping Diagrams.. 6. Wiring Diagrams.. 7. Capacity Tables 8 Capacity correction factors 9. Static Pressure.. 10. Electric Characteristics..... 11. Sound Levels - 6 -

1. Features (1) In case the ceiling is super-high. --Blowing pressure of Indoor Unit can reach 196Pa. The air conditioner delivers cold wind to every indoor corner even the ceiling is super-high. --The max. distance of air supply is about 14m, the height of air supply is 6.5m. (2) Multi-blowing outlets To satisfy your fitment s needs. (3) Fresh air supply. Fresh air can be drawn in by the Indoor Unit, which improves the Indoor Air Quality greatly. (4) Wired control and group control available. (5) High capacity of cooling/heating, efficient, and energy-saving. (6) Innovative air supply, which provides homogeneous conditioning of the room temperature. (7) It is suitable be used for office, hospital, commercial place and home, the air conditioner will create the comfortable and elegance environment for you. - 7 -

2. Specifications Model (Cooling) MHB-76CR MHB-96CR Code 220070900100 220070900060 Power supply V- ph-hz 220-240~1~50 Capacity Btu/h 76000 96000 Cooling Input W 8100 10000 Rated current A 14.7 16.5 Model YDK550-4X( 2) YDK550-4X( 2) Type AC motor AC motor Indoor fan motor Brand Yongan Yongan Input W 900/820/630( 2) 900/820/630( 2) Capacitor uf 15( 2) 15( 2) Speed (hi/mid/lo) r/min 1300/1100/900( 2) 1300/1100/900( 2) Number of rows 4 4 Tube pitch(a)x row pitch(b) mm 25.4x22 25.4x22 Fin spacing mm 1.7 1.7 Indoor coil Fin type Tube outside dia. and type mm hydrophilic actuate fin alum inurn foil Ф9.53 Ф9.53 innergroove tube innergroove tube Coil length x height x width mm 1202 406 88 1202 406 88 Number of circuits 8 8 Indoor air flow (H/M/L) m 3 /h 4500/3810/3200 4500/3810/3200 Indoor external static pressure (Hi) Pa 196 196 Indoor noise level (Hi/Mid/Lo) (Pressure sound) db(a) 48/46/44 48/46/44 Dimension (WxHxD) mm 1350 760 450 1350 760 450 Indoor unit Packing (WxHxD) mm 1549x917x476 1549x917x476 Net/Gross weight kg 105/120 105/120 Refrigerant type R22 R22 Throttle Capillary Design pressure MPa 2.6/1.0 2.6/1.0 Liquid side/ Gas side mm(inch) Ф9.53/Ф19 Ф9.53/Ф19 Refrigerant piping Max. refrigerant pipe length m 30 30 Max. difference in level m 20 20 Connecting wiring Power wiring mm 2 3 2.5 3 2.5 Signal wiring mm 2 3 1.0 3 1.0 Drainage water pipe dia. mm Ф32 Ф32 Controller Wireless remote controller (R51/CE) (standard) Operation temp 17~30 17~30 Application area m 2 80~120 100~150 Notes: 1. Nominal cooling capacities are based on the following conditions: Indoor temp: 27 CDB, 19 CWB; Outdoor temp: 35 CDB; Equivalent ref. piping: 7.5m (horizontal) - 8 -

Model (Cooling & Heating) MHB-76HR MHB-96HR Code 220070900090 220070900050 Power supply V- ph-hz 220-240~1~50 Capacity Btu/h 76000 96000 Cooling Input W 8100 10200 Rated current A 14.7 16.7 Capacity Btu/h 83600 105600 Heating Input W 8000 9800 Rated current A 14.5 16.3 Model YDK550-4X ( 2) YDK550-4X ( 2) Type AC motor AC motor Indoor fan motor Brand Yongan Yongan Input W 900/820/630 ( 2) 900/820/630 ( 2) Capacitor uf 15 ( 2) 15 ( 2) Speed (hi/mid/lo) r/min 1300/1100/900 ( 2) 1300/1100/900 ( 2) Number of rows 4 4 Tube pitch(a)x row pitch(b) mm 25.4x22 25.4x22 Fin spacing mm 1.7 1.7 Fin type hydrophilic actuate fin alum inurn foil Indoor coil Ф9.53 Ф9.53 Tube outside dia. and type mm innergroove tube innergroove tube Coil length x height x width mm 1202 406 88 1202 406 88 Number of circuits 8 8 Indoor air flow (H/M/L) m 3 /h 4500/3810/3200 4500/3810/3200 Indoor external static pressure (Hi) Pa 196 196 Indoor noise level (Hi/Mid/Lo) (Pressure sound) db(a) 48/46/44 48/46/44 Dimension (WxHxD) mm 1350 760 450 1350 760 450 Indoor unit Packing (WxHxD) mm 1549x917x476 1549x917x476 Net/Gross weight kg 105/120 105/120 Refrigerant type R22 R22 Throttle Capillary Design pressure MPa 2.6/1.0 2.6/1.0 Liquid side/ Gas side mm(inch) Ф9.53/Ф19 Ф9.53/Ф19 Refrigerant piping Max. refrigerant pipe length m 30 30 Max. difference in level m 20 20 Connecting wiring Power wiring mm 2 3 2.5 3 2.5 Signal wiring mm 2 4 1.0 4 1.0 Drainage water pipe dia. mm Ф32 Ф32 Controller Wireless remote controller (R51/E) (standard) Operation temp 17~30 17~30 Application area m 2 80~120 100~150 Notes: 1. Nominal cooling capacities are based on the following conditions: Indoor temp: 27 CDB, 19 CWB; Outdoor temp: 35 CDB; Equivalent ref. piping: 7.5m (horizontal) 2. Nominal heating capacities are based on the following conditions: Indoor temp: 20 CDB; Outdoor temp: 7 CDB, 6 CWB; Equivalent ref. piping: 7.5m (horizontal) - 9 -

Model (Cooling & Heating) MHA-150HR Code 220070900040 Power supply V- ph-hz 220-240-1-50 Capacity Btu/h 150000 Cooling Input W 16000 Rated current A 30 Capacity Btu/h 165000 Heating Input W 17000 Rated current A 32 Model YDK550-4X ( 3) Type AC Motor Indoor fan motor Input W 900/820/630 ( 3) Capacitor uf 15uF/370-450V ( 3) Speed (hi/mid/lo) r/min 1300/1100/900 ( 3) Number of rows 2 Tube pitch(a)x row pitch(b) mm 21 13.37 Fin spacing mm 1.5 Indoor coil Fin type Hydrophilic aluminium Tube outside dia. and type mm 7/Innergroove tube Coil length x height x width mm 1602 609 53.48 Number of circuits 22 Indoor air flow (H/L) m 3 /h 8000/5500 Indoor external static pressure (Hi) Pa 196 Indoor noise level (H/L) db(a) 45/41 Dimension (W H D) mm 1916 668 903 Indoor unit Packing (W H D) mm 2095X689X929 Net/Gross weight kg 188/220 Refrigerant type R22 Throttle type Capillary Design pressure MPa 2.6/1.0 Refrigerant piping Liquid side/ Gas side mm(inch) Ф16/Ф35 Connecting wiring Power wiring mm 2 3 2.5 Signal wiring mm 2 4 1.0 Drainage water pipe dia. mm Ф32 Controller Wireless remote controller (R51/E) (standard) Operation temp 17~30 Application area m 2 180~240 Notes: 1. Nominal cooling capacities are based on the following conditions: Indoor temp: 27 CDB, 19 CWB; Outdoor temp: 35 CDB; Equivalent ref. piping: 7.5m (horizontal) 2. Nominal heating capacities are based on the following conditions: Indoor temp: 20 CDB; Outdoor temp: 7 CDB, 6 CWB; Equivalent ref. piping: 7.5m (horizontal) - 10 -

3. Dimensions 3.1 MHB-76CR MHB-96CR MHB-76HR MHB-96HR Air outlet duct connection screw hole location diagram: Return air duct rivet screw hole location diagram: Install Ф10 pendant bolts or ground bolts: - 11 -

3.2 MHA-150HR Air outlet duct connection screw hole location diagram: Return air duct rivet screw hole location diagram: Install Ф10 pendant bolts or ground bolts: - 12 -

4. Service Space Ensure enough space required for installation and maintenance. Key points of duct connection: - 13 -

5. Piping Diagrams 5.1 MHB-76CR MHB-96CR Outdoor Unit Indoor Unit Condenser 1 Condenser 2 Capillary Evaporator 1 Evaporator 2 Comp 1 Comp 2 Vapor-liquid separator 5.2 MHB-76R MHB-96R Outdoor Unit Indoor Unit ST1 ST2 Condenser 1 Condenser 2 Capillary Evaporator 2 Evaporator 1 Comp 1 Comp 2 Vapor-liquid separator - 14 -

5.3 MHA-150HR - 15 -

6. Wiring Diagrams 6.1 MHB-76CR MHB-96CR - 16 -

6.2 MHB-76R MHB-96R - 17 -

6.3 MHA-150HR - 18 -

7. Capacity Tables 7.1 Cooling: MHB-76CR MHB-76HR High speed at 4500 m 3 /h Outdoor air entering Temp(DB) Indoor air entering Temp 70 0 F/21ºC 82 0 F/28ºC 95 0 F/35ºC 109 0 F/43ºC 115 0 F/46ºC 126 0 F/52ºC 129 0 F/54ºC Tcc(kW) 22.94 21.82 20.71 19.82 19.15 18.04 16.70 70 0F/21ºC DB Scc(kW) 16.97 16.80 16.57 16.65 16.28 15.87 15.03 59 0F/15ºC WB PW(kW) 6.72 7.29 7.61 7.86 8.18 8.75 9.15 Tcc(kW) 23.61 22.49 21.38 20.04 19.60 18.48 17.37 75 0F/24ºC DB Scc(kW) 17.70 17.54 17.32 16.84 16.66 16.27 15.63 63 0F/17ºC WB PW(kW) 7.13 7.61 7.94 8.34 8.67 9.15 9.56 Tcc(kW) 24.05 22.94 22.27 20.71 20.27 19.15 18.04 80 0F/27ºC DB Scc(kW) 17.80 17.66 17.37 16.98 16.82 16.47 15.69 66 0F/19ºC WB PW(kW) 7.29 7.70 8.10 8.51 8.83 9.07 9.72 Tcc(kW) 24.27 23.16 22.72 20.93 20.38 19.37 18.26 84 0F/29ºC DB Scc(kW) 20.39 19.69 19.54 19.05 19.15 18.60 17.71 66 0F/19ºC WB PW(kW) 7.45 7.86 8.18 8.67 9.15 9.56 9.96 Tcc(kW) 24.50 23.61 23.16 21.38 20.71 20.04 18.71 90 0F/32ºC DB Scc(kW) 20.82 20.54 20.38 19.88 19.88 19.44 18.52 73 0F/23ºC WB PW(kW) 7.61 7.94 8.51 8.83 9.32 9.96 10.21 Medium speed at 3810 m 3 /h Outdoor air entering Temp(DB) Indoor air entering Temp 70 0F/21ºC 82 0F/28ºC 95 0F/35ºC 109 0F/43ºC 115 0F/46ºC 126 0F/52ºC 1290F/54ºC 70 0F/21ºC DB Tcc(kW) 22.01 20.94 19.87 19.02 18.38 17.31 16.03 59 0F/15ºC WB Scc(kW) 16.29 16.13 15.90 15.98 15.62 15.23 14.42 PW(kW) 6.46 7.00 7.31 7.55 7.86 8.40 8.79 75 0F/24ºC DB Tcc(kW) 22.65 21.58 20.52 19.23 18.81 17.74 16.67 63 0F/17ºC WB Scc(kW) 16.99 16.84 16.62 16.16 15.98 15.61 15.00 PW(kW) 6.85 7.31 7.62 8.01 8.32 8.79 9.18 80 0F/27ºC DB Tcc(kW) 23.08 22.01 21.37 19.87 19.45 18.38 17.31 66 0F/19ºC WB Scc(kW) 17.08 16.95 16.67 16.30 16.14 15.81 15.06 PW(kW) 7.00 7.39 7.78 8.17 8.48 8.71 9.34 84 0F/29ºC DB Tcc(kW) 23.29 22.22 21.80 20.09 19.55 18.59 17.52 66 0F/19ºC WB Scc(kW) 19.57 18.89 18.75 18.28 18.38 17.85 17.00 PW(kW) 7.16 7.55 7.86 8.32 8.79 9.18 9.57 90 0F/32ºC DB Tcc(kW) 23.51 22.65 22.22 20.52 19.87 19.23 17.95 73 0F/23ºC WB Scc(kW) 19.98 19.71 19.56 19.08 19.08 18.66 17.77 PW(kW) 7.31 7.62 8.17 8.48 8.95 9.57 9.80-19 -

Low speed at 3200 m 3 /h Indoor air entering Outdoor air entering Temp(DB) Temp 70 0 F/21ºC 82 0 F/28ºC 95 0 F/35ºC 109 0 F/43ºC 115 0 F/46ºC 126 0 F/52ºC 129 0 F/54ºC 70 0 F/21ºC DB Tcc(kW) 21.14 20.11 19.08 18.26 17.65 16.62 15.39 59 0 F/15ºC WB Scc(kW) 15.64 15.48 15.27 15.34 15.00 14.63 13.85 PW(kW) 6.19 6.71 7.01 7.24 7.53 8.06 8.43 75 0 F/24ºC DB Tcc(kW) 21.75 20.73 19.70 18.47 18.06 17.03 16.01 63 0 F/17ºC WB Scc(kW) 16.31 16.17 15.96 15.51 15.35 14.99 14.41 PW(kW) 6.56 7.01 7.31 7.68 7.98 8.43 8.80 80 0 F/27ºC DB Tcc(kW) 22.16 21.14 20.52 19.08 18.67 17.65 16.62 66 0 F/19ºC WB Scc(kW) 16.40 16.27 16.01 15.65 15.50 15.18 14.46 PW(kW) 6.71 7.09 7.46 7.83 8.13 8.36 8.95 84 0 F/29ºC DB Tcc(kW) 22.37 21.34 20.93 19.29 18.78 17.85 16.83 66 0 F/19ºC WB Scc(kW) 18.79 18.14 18.00 17.55 17.65 17.14 16.32 PW(kW) 6.86 7.24 7.53 7.98 8.43 8.80 9.18 90 0 F/32ºC DB Tcc(kW) 22.57 21.75 21.34 19.70 19.08 18.47 17.24 73 0 F/23ºC WB Scc(kW) 19.19 18.92 18.78 18.32 18.32 17.91 17.06 PW(kW) 7.01 7.31 7.83 8.13 8.58 9.18 9.40-20 -

MHB-96CR High speed at 4500 m 3 /h Outdoor air entering Temp(DB) Indoor air entering Temp 70 0 F/21ºC 82 0 F/28ºC 95 0 F/35ºC 109 0 F/43ºC 115 0 F/46ºC 126 0 F/52ºC 129 0 F/54ºC 70 0 F/21ºC DB Tcc(kW) 28.98 27.58 26.17 25.04 24.20 22.79 21.11 59 0 F/15ºC WB Scc(kW) 21.45 21.23 20.94 21.04 20.57 20.06 18.99 PW(kW) 8.30 9.00 9.40 9.70 10.10 10.80 11.30 75 0 F/24ºC DB Tcc(kW) 29.83 28.42 27.01 25.33 24.76 23.36 21.95 63 0 F/17ºC WB Scc(kW) 22.37 22.17 21.88 21.27 21.05 20.55 19.75 PW(kW) 8.80 9.40 9.80 10.30 10.70 11.30 11.80 80 0 F/27ºC DB Tcc(kW) 30.39 28.98 28.14 26.17 25.61 24.20 22.79 66 0 F/19ºC WB Scc(kW) 22.49 22.32 21.95 21.46 21.25 20.81 19.83 PW(kW) 9.00 9.50 10.00 10.50 10.90 11.20 12.00 84 0 F/29ºC DB Tcc(kW) 30.67 29.27 28.70 26.45 25.75 24.48 23.07 66 0 F/19ºC WB Scc(kW) 25.76 24.88 24.68 24.07 24.20 23.50 22.38 PW(kW) 9.20 9.70 10.10 10.70 11.30 11.80 12.30 90 0 F/32ºC DB Tcc(kW) 30.95 29.83 29.27 27.01 26.17 25.33 23.64 73 0 F/23ºC WB Scc(kW) 26.31 25.95 25.75 25.12 25.12 24.57 23.40 PW(kW) 9.40 9.80 10.50 10.90 11.50 12.30 12.60 Medium speed at 3810 m 3 /h Outdoor air entering Temp(DB) Indoor air entering Temp 70 0 F/21ºC 82 0 F/28ºC 95 0 F/35ºC 109 0 F/43ºC 115 0 F/46ºC 126 0 F/52ºC 129 0 F/54ºC 70 0 F/21ºC DB Tcc(kW) 27.83 26.48 25.13 24.05 23.24 21.89 20.27 59 0 F/15ºC WB Scc(kW) 20.59 20.39 20.10 20.20 19.75 19.26 18.24 PW(kW) 7.97 8.64 9.02 9.31 9.70 10.37 10.85 75 0 F/24ºC DB Tcc(kW) 28.64 27.29 25.94 24.32 23.78 22.43 21.08 63 0 F/17ºC WB Scc(kW) 21.48 21.29 21.01 20.43 20.21 19.74 18.97 PW(kW) 8.45 9.02 9.41 9.89 10.27 10.85 11.33 80 0 F/27ºC DB Tcc(kW) 29.18 27.83 27.02 25.13 24.59 23.24 21.89 66 0 F/19ºC WB Scc(kW) 21.59 21.43 21.08 20.61 20.41 19.98 19.04 PW(kW) 8.64 9.12 9.60 10.08 10.46 10.75 11.52 84 0 F/29ºC DB Tcc(kW) 29.45 28.10 27.56 25.40 24.72 23.51 22.16 66 0 F/19ºC WB Scc(kW) 24.74 23.89 23.70 23.11 23.24 22.57 21.49 PW(kW) 8.83 9.31 9.70 10.27 10.85 11.33 11.81 90 0 F/32ºC DB Tcc(kW) 29.72 28.64 28.10 25.94 25.13 24.32 22.70 73 0 F/23ºC WB Scc(kW) 25.26 24.92 24.73 24.12 24.12 23.59 22.47 PW(kW) 9.02 9.41 10.08 10.46 11.04 11.81 12.10-21 -

Low speed at 3200 m 3 /h Indoor air entering Outdoor air entering Temp(DB) Temp 70 0 F/21ºC 82 0 F/28ºC 95 0 F/35ºC 109 0 F/43ºC 115 0 F/46ºC 126 0 F/52ºC 129 0 F/54ºC 70 0 F/21ºC DB Tcc(kW) 26.72 25.42 24.12 23.09 22.31 21.01 19.46 59 0 F/15ºC WB Scc(kW) 19.77 19.57 19.30 19.39 18.96 18.49 17.51 PW(kW) 7.64 8.29 8.66 8.93 9.30 9.95 10.41 75 0 F/24ºC DB Tcc(kW) 27.50 26.20 24.90 23.35 22.83 21.53 20.23 63 0 F/17ºC WB Scc(kW) 20.62 20.44 20.17 19.61 19.40 18.95 18.21 PW(kW) 8.10 8.66 9.03 9.49 9.85 10.41 10.87 80 0 F/27ºC DB Tcc(kW) 28.02 26.72 25.94 24.12 23.61 22.31 21.01 66 0 F/19ºC WB Scc(kW) 20.73 20.57 20.23 19.78 19.59 19.19 18.28 PW(kW) 8.29 8.75 9.21 9.67 10.04 10.32 11.05 84 0 F/29ºC DB Tcc(kW) 28.27 26.98 26.46 24.38 23.74 22.57 21.27 66 0 F/19ºC WB Scc(kW) 23.75 22.93 22.75 22.19 22.31 21.67 20.63 PW(kW) 8.47 8.93 9.30 9.85 10.41 10.87 11.33 90 0 F/32ºC DB Tcc(kW) 28.53 27.50 26.98 24.90 24.12 23.35 21.79 73 0 F/23ºC WB Scc(kW) 24.25 23.92 23.74 23.16 23.16 22.65 21.57 PW(kW) 8.66 9.03 9.67 10.04 10.59 11.33 11.60-22 -

MHB-96HR High speed at 4500 m 3 /h Outdoor air entering Temp(DB) Indoor air entering Temp 70 0 F/21ºC 82 0 F/28ºC 95 0 F/35ºC 109 0 F/43ºC 115 0 F/46ºC 126 0 F/52ºC 129 0 F/54ºC 70 0 F/21ºC DB Tcc(kW) 28.98 27.58 26.17 25.04 24.20 22.79 21.11 59 0 F/15ºC WB Scc(kW) 21.45 21.23 20.94 21.04 20.57 20.06 18.99 PW(kW) 8.47 9.18 9.59 9.89 10.30 11.02 11.53 75 0 F/24ºC DB Tcc(kW) 29.83 28.42 27.01 25.33 24.76 23.36 21.95 63 0 F/17ºC WB Scc(kW) 22.37 22.17 21.88 21.27 21.05 20.55 19.75 PW(kW) 8.98 9.59 10.00 10.51 10.91 11.53 12.04 80 0 F/27ºC DB Tcc(kW) 30.39 28.98 28.14 26.17 25.61 24.20 22.79 66 0 F/19ºC WB Scc(kW) 22.49 22.32 21.95 21.46 21.25 20.81 19.83 PW(kW) 9.18 9.69 10.20 10.71 11.12 11.42 12.24 84 0 F/29ºC DB Tcc(kW) 30.67 29.27 28.70 26.45 25.75 24.48 23.07 66 0 F/19ºC WB Scc(kW) 25.76 24.88 24.68 24.07 24.20 23.50 22.38 PW(kW) 9.38 9.89 10.30 10.91 11.53 12.04 12.55 90 0 F/32ºC DB Tcc(kW) 30.95 29.83 29.27 27.01 26.17 25.33 23.64 73 0 F/23ºC WB Scc(kW) 26.31 25.95 25.75 25.12 25.12 24.57 23.40 PW(kW) 9.59 10.00 10.71 11.12 11.73 12.55 12.85 Medium speed at 3810 m 3 /h Indoor air entering Outdoor air entering Temp(DB) Temp 70 0 F/21ºC 82 0 F/28ºC 95 0 F/35ºC 109 0 F/43ºC 115 0 F/46ºC 126 0 F/52ºC 129 0 F/54ºC 70 0 F/21ºC DB Tcc(kW) 27.83 26.48 25.13 24.05 23.24 21.89 20.27 59 0 F/15ºC WB Scc(kW) 20.59 20.39 20.10 20.20 19.75 19.26 18.24 PW(kW) 8.13 8.81 9.20 9.50 9.89 10.57 11.06 75 0 F/24ºC DB Tcc(kW) 28.64 27.29 25.94 24.32 23.78 22.43 21.08 63 0 F/17ºC WB Scc(kW) 21.48 21.29 21.01 20.43 20.21 19.74 18.97 PW(kW) 8.62 9.20 9.59 10.08 10.48 11.06 11.55 80 0 F/27ºC DB Tcc(kW) 29.18 27.83 27.02 25.13 24.59 23.24 21.89 66 0 F/19ºC WB Scc(kW) 21.59 21.43 21.08 20.61 20.41 19.98 19.04 PW(kW) 8.81 9.30 9.79 10.28 10.67 10.96 11.75 84 0 F/29ºC DB Tcc(kW) 29.45 28.10 27.56 25.40 24.72 23.51 22.16 66 0 F/19ºC WB Scc(kW) 24.74 23.89 23.70 23.11 23.24 22.57 21.49 PW(kW) 9.01 9.50 9.89 10.48 11.06 11.55 12.04 90 0 F/32ºC DB Tcc(kW) 29.72 28.64 28.10 25.94 25.13 24.32 22.70 73 0 F/23ºC WB Scc(kW) 25.26 24.92 24.73 24.12 24.12 23.59 22.47 PW(kW) 9.20 9.59 10.28 10.67 11.26 12.04 12.34-23 -

Low speed at 3200 m 3 /h Indoor air entering Outdoor air entering Temp(DB) Temp 70 0 F/21ºC 82 0 F/28ºC 95 0 F/35ºC 109 0 F/43ºC 115 0 F/46ºC 126 0 F/52ºC 129 0 F/54ºC 70 0 F/21ºC DB Tcc(kW) 26.72 25.42 24.12 23.09 22.31 21.01 19.46 59 0 F/15ºC WB Scc(kW) 19.77 19.57 19.30 19.39 18.96 18.49 17.51 PW(kW) 7.80 8.46 8.84 9.12 9.49 10.15 10.62 75 0 F/24ºC DB Tcc(kW) 27.50 26.20 24.90 23.35 22.83 21.53 20.23 63 0 F/17ºC WB Scc(kW) 20.62 20.44 20.17 19.61 19.40 18.95 18.21 PW(kW) 8.27 8.84 9.21 9.68 10.06 10.62 11.09 80 0 F/27ºC DB Tcc(kW) 28.02 26.72 25.94 24.12 23.61 22.31 21.01 66 0 F/19ºC WB Scc(kW) 20.73 20.57 20.23 19.78 19.59 19.19 18.28 PW(kW) 8.46 8.93 9.40 9.87 10.25 10.53 11.28 84 0 F/29ºC DB Tcc(kW) 28.27 26.98 26.46 24.38 23.74 22.57 21.27 66 0 F/19ºC WB Scc(kW) 23.75 22.93 22.75 22.19 22.31 21.67 20.63 PW(kW) 8.65 9.12 9.49 10.06 10.62 11.09 11.56 90 0 F/32ºC DB Tcc(kW) 28.53 27.50 26.98 24.90 24.12 23.35 21.79 73 0 F/23ºC WB Scc(kW) 24.25 23.92 23.74 23.16 23.16 22.65 21.57 PW(kW) 8.84 9.21 9.87 10.25 10.81 11.56 11.84-24 -

MHA-150HR High speed at 8000 m 3 /h Indoor air Outdoor air entering Temp(DB) entering Temp 70 0 F/21ºC 82 0 F/28ºC 95 0 F/35ºC 109 0 F/43ºC 115 0 F/46ºC 126 0 F/52ºC 129 0 F/54ºC 70 0 F/21ºC DB Tcc(kW) 45.32 43.12 40.92 39.16 37.84 35.64 33.00 59 0 F/15ºC WB Scc(kW) 33.54 33.20 32.74 32.89 32.16 31.36 29.70 PW(kW) 13.28 14.40 15.04 15.52 16.16 17.28 18.08 75 0 F/24ºC DB Tcc(kW) 46.64 44.44 42.24 39.60 38.72 36.52 34.32 63 0 F/17ºC WB Scc(kW) 34.98 34.66 34.21 33.26 32.91 32.14 30.89 PW(kW) 14.08 15.04 15.68 16.48 17.12 18.08 18.88 80 0 F/27ºC DB Tcc(kW) 47.52 45.32 44.00 40.92 40.04 37.84 35.64 66 0 F/19ºC WB Scc(kW) 35.16 34.90 34.32 33.55 33.23 32.54 31.01 PW(kW) 14.40 15.20 16.00 16.80 17.44 17.92 19.20 84 0 F/29ºC DB Tcc(kW) 47.96 45.76 44.88 41.36 40.26 38.28 36.08 66 0 F/19ºC WB Scc(kW) 40.29 38.90 38.60 37.64 37.84 36.75 35.00 PW(kW) 14.72 15.52 16.16 17.12 18.08 18.88 19.68 90 0 F/32ºC DB Tcc(kW) 48.40 46.64 45.76 42.24 40.92 39.60 36.96 73 0 F/23ºC WB Scc(kW) 41.14 40.58 40.27 39.28 39.28 38.41 36.59 PW(kW) 15.04 15.68 16.80 17.44 18.40 19.68 20.16 Medium speed at 6800 m 3 /h Indoor air Outdoor air entering Temp(DB) entering Temp 70 0 F/21ºC 82 0 F/28ºC 95 0 F/35ºC 109 0 F/43ºC 115 0 F/46ºC 126 0 F/52ºC 129 0 F/54ºC 70 0 F/21ºC DB Tcc(kW) 43.47 41.36 39.25 37.56 36.29 34.18 31.65 59 0 F/15ºC WB Scc(kW) 32.16 31.84 31.40 31.55 30.85 30.08 28.49 PW(kW) 12.75 13.82 14.44 14.90 15.51 16.59 17.36 75 0 F/24ºC DB Tcc(kW) 44.73 42.62 40.51 37.98 37.14 35.03 32.92 63 0 F/17ºC WB Scc(kW) 33.55 33.25 32.81 31.90 31.57 30.82 29.62 PW(kW) 13.52 14.44 15.05 15.82 16.44 17.36 18.12 80 0 F/27ºC DB Tcc(kW) 45.58 43.47 42.20 39.25 38.40 36.29 34.18 66 0 F/19ºC WB Scc(kW) 33.73 33.47 32.92 32.18 31.87 31.21 29.74 PW(kW) 13.82 14.59 15.36 16.13 16.74 17.20 18.43 84 0 F/29ºC DB Tcc(kW) 46.00 43.89 43.04 39.67 38.61 36.71 34.60 66 0 F/19ºC WB Scc(kW) 38.64 37.30 37.02 36.10 36.30 35.25 33.57 PW(kW) 14.13 14.90 15.51 16.44 17.36 18.12 18.89 90 0 F/32ºC DB Tcc(kW) 46.42 44.73 43.89 40.51 39.25 37.98 35.45 73 0 F/23ºC WB Scc(kW) 39.46 38.92 38.62 37.68 37.68 36.84 35.09 PW(kW) 14.44 15.05 16.13 16.74 17.66 18.89 19.35-25 -

Low speed at 5500 m 3 /h Indoor air Outdoor air entering Temp(DB) entering Temp 70 0 F/21ºC 82 0 F/28ºC 95 0 F/35ºC 109 0 F/43ºC 115 0 F/46ºC 126 0 F/52ºC 129 0 F/54ºC 70 0 F/21ºC DB Tcc(kW) 41.73 39.70 37.67 36.05 34.84 32.81 30.38 59 0 F/15ºC WB Scc(kW) 30.88 30.57 30.14 30.29 29.61 28.88 27.34 PW(kW) 12.23 13.27 13.86 14.30 14.89 15.92 16.66 75 0 F/24ºC DB Tcc(kW) 42.94 40.92 38.89 36.46 35.65 33.62 31.60 63 0 F/17ºC WB Scc(kW) 32.21 31.91 31.50 30.63 30.30 29.59 28.44 PW(kW) 12.97 13.86 14.45 15.18 15.77 16.66 17.39 80 0 F/27ºC DB Tcc(kW) 43.75 41.73 40.51 37.67 36.86 34.84 32.81 66 0 F/19ºC WB Scc(kW) 32.38 32.13 31.60 30.89 30.60 29.96 28.55 PW(kW) 13.27 14.00 14.74 15.48 16.07 16.51 17.69 84 0 F/29ºC DB Tcc(kW) 44.16 42.13 41.32 38.08 37.07 35.24 33.22 66 0 F/19ºC WB Scc(kW) 37.09 35.81 35.54 34.65 34.84 33.83 32.22 PW(kW) 13.56 14.30 14.89 15.77 16.66 17.39 18.13 90 0 F/32ºC DB Tcc(kW) 44.56 42.94 42.13 38.89 37.67 36.46 34.03 73 0 F/23ºC WB Scc(kW) 37.88 37.36 37.07 36.17 36.17 35.37 33.69 PW(kW) 13.86 14.45 15.48 16.07 16.95 18.13 18.57-26 -

7.2 Heating: MHB-76HR High speed at 4500 m 3 /h Outdoor DB ( C) 24 7 2-5 -7 outdoor WB ( C) 18 6 1-6 -8 Evap. MODEL Entering Air DB ( C) TC KW TC KW TC KW TC KW TC KW Capacity (kw) 15 31.85 8.64 25.73 7.44 21.07 6.40 19.11 6.00 17.89 5.68 MHB-76HR 20 30.87 9.44 24.50 8.00 19.85 7.04 18.62 6.48 17.15 6.08 Medium speed at 3810 m 3 /h 27 28.91 10.00 23.03 8.64 18.62 7.60 18.13 7.04 16.17 6.56 Outdoor DB ( C) 24 7 2-5 -7 outdoor WB ( C) 18 6 1-6 -8 Evap. MODEL Entering Air DB ( C) TC KW TC KW TC KW TC KW TC KW Capacity (kw) 15 30.58 8.29 24.70 7.14 20.23 6.14 18.35 5.76 17.17 5.45 MHB-76HR 20 29.64 9.06 23.52 7.68 19.05 6.76 17.88 6.22 16.46 5.84 Low speed at 3200 m 3 /h 27 27.75 9.60 22.11 8.29 17.88 7.30 17.40 6.76 15.52 6.30 Outdoor DB ( C) 24 7 2-5 -7 outdoor WB ( C) 18 6 1-6 -8 Evap. MODEL Entering Air DB ( C) TC KW TC KW TC KW TC KW TC KW Capacity (kw) 15 29.35 7.96 23.71 6.85 19.42 5.90 17.61 5.53 16.48 5.23 MHB-76HR 20 28.45 8.70 22.58 7.37 18.29 6.49 17.16 5.97 15.81 5.60 27 26.64 9.21 21.23 7.96 17.16 7.00 16.71 6.49 14.90 6.04-27 -

MHB-96HR High speed at 4500 m 3 /h Outdoor DB ( C) 24 7 2-5 -7 outdoor WB ( C) 18 6 1-6 -8 Evap. MODEL Entering Air DB ( C) TC KW TC KW TC KW TC KW TC KW Capacity (kw) 15 40.24 10.58 32.50 9.11 26.62 7.84 24.14 7.35 22.59 6.96 MHB-96HR 20 39.00 11.56 30.95 9.80 25.07 8.62 23.52 7.94 21.67 7.45 Medium speed at 3810 m 3 /h 27 36.52 12.25 29.09 10.58 23.52 9.31 22.90 8.62 20.43 8.04 Outdoor DB ( C) 24 7 2-5 -7 outdoor WB ( C) 18 6 1-6 -8 Evap. MODEL Entering Air DB ( C) TC KW TC KW TC KW TC KW TC KW Capacity (kw) 15 38.64 10.15 31.21 8.74 25.56 7.52 23.18 7.05 21.70 6.67 MHB-96HR 20 37.45 11.09 29.72 9.40 24.07 8.27 22.59 7.61 20.80 7.14 Low speed at 3200 m 3 /h 27 35.07 11.75 27.94 10.15 22.59 8.93 21.99 8.27 19.62 7.71 Outdoor DB ( C) 24 7 2-5 -7 outdoor WB ( C) 18 6 1-6 -8 Evap. MODEL Entering Air DB ( C) TC KW TC KW TC KW TC KW TC KW Capacity (kw) 15 37.10 9.75 29.97 8.40 24.54 7.22 22.26 6.77 20.83 6.41 MHB-96HR 20 35.96 10.66 28.54 9.03 23.12 7.95 21.69 7.31 19.98 6.86 27 33.68 11.29 26.83 9.75 21.69 8.58 21.12 7.95 18.84 7.40-28 -

MHA-150HR High speed at 8000 m 3 /h Outdoor DB ( C) 24 7 2-5 -7 outdoor WB ( C) 18 6 1-6 -8 Evap. MODEL Entering Air DB ( C) TC KW TC KW TC KW TC KW TC KW Capacity (kw) 15 62.87 18.36 50.78 15.81 41.59 13.60 37.72 12.75 35.30 12.07 MKH25 20 60.93 20.06 48.36 17.00 39.17 14.96 36.75 13.77 33.85 12.92 27 57.06 21.25 45.46 18.36 36.75 16.15 35.79 14.96 31.92 13.94 Medium speed at 6800 m 3 /h Outdoor DB ( C) 24 7 2-5 -7 outdoor WB ( C) 18 6 1-6 -8 Evap. MODEL Entering Air DB ( C) TC KW TC KW TC KW TC KW TC KW Capacity (kw) 15 60.36 17.63 48.75 15.18 39.93 13.06 36.22 12.24 33.89 11.59 MKH25 20 58.50 19.26 46.43 16.32 37.61 14.36 35.29 13.22 32.50 12.40 27 54.79 20.40 43.64 17.63 35.29 15.50 34.36 14.36 30.64 13.38 Low speed at 5500 m 3 /h Outdoor DB ( C) 24 7 2-5 -7 outdoor WB ( C) 18 6 1-6 -8 Evap. MODEL Entering Air DB ( C) TC KW TC KW TC KW TC KW TC KW Capacity (kw) 15 57.94 16.91 46.80 14.56 38.33 12.53 34.76 11.75 32.54 11.12 MKH25 20 56.16 18.48 44.57 15.66 36.10 13.78 33.87 12.68 31.20 11.90 27 52.59 19.58 41.90 16.91 33.87 14.88 32.98 13.78 29.42 12.84-29 -

8 Capacity correction factors 8.1 Correction factor of indoor air-flow changing rate Unit Model Air flow (m 3 /h) Air delivery capacity correction factor Total Sensible 5000 1.05 1.08 MHB-76C(H)R 4500 1 1 3810 0.96 0.92 3200 0.92 0.85 5000 1.05 1.08 MHB-96C(H)R 4500 1 1 3810 0.96 0.92 3200 0.92 0.85 8500 1.05 1.08 MHA-150HR 8000 1 1 6800 0.96 0.92 5500 0.92 0.85 8.2 Correction factor of the length and elevation difference of refrigerant pipe 50 Outdoor unit 40 30 20 10 0 % 100 98 96 94 92 90 88 86-10 - 20-30 10 20 30 40 50 60 Pipe equivalent length L (m) - 30 -

9. Static Pressure 9.1 For 76000Btu/h and 96000Btu/h 250 External static pressure (Pa) 225 200 175 150 125 100 75 Midium speed High speed Low speed 50 25 2800 3200 3600 4000 4400 3 Air volume(m /h) 4800 5200 5600 9.2 For 150000Btu/h Pa 200 180 160 High speed External static pressure (Pa) 140 120 100 80 60 3 Min air volume5500m /h Low speed 40 3 Max air volume8000m /h 20 4500 5000 5500 6000 3 Air volume(m /h) 6500 7000 7500 8000-31 -

10. Electric Characteristics Indoor Unit Power Supply IFM Model Hz Voltage Min. Max. MCA MFA KW FLA MHB-76HR 50 220V 198V 242V 10.8 35 0.55 2 8.6 MHB-76CR 50 220V 198V 242V 10.8 35 0.55 2 8.6 MHB-96HR 50 220V 198V 242V 10.8 35 0.55 2 8.6 MHB-96CR 50 220V 198V 242V 10.8 35 0.55 2 8.6 MHA-150HR 50 220V 198V 242V 10 30 0.55 3 12.9 Remark: MCA: Min. Current Amps. (A) MFA: Max. Fuse Amps. (A) KW: Fan Motor Rated Output (KW) FLA: Full Load Amps. (A) IFM: Indoor Fan Motor 11. Sound Levels Concealed Duct Type Discharge Duct Suction 1.4m Microphone Unit Number Model Noise level under three speeds of fan (db(a)) H M L 1 MHB-76HR 48 46 44 2 MHB-96HR 48 46 44 3 MHB-76CR 48 46 44 4 MHB-96CR 48 46 44 5 MHA-150HR 45 / 41-32 -