For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X. Air Cooled Medical Chiller Product Data Catalog

Similar documents
Air Cooled Chiller Product Data Catalog. Air Cooled Template

Water-to-Water Heat Pump Product Data Catalog R-134a Modules MR010AN, MR015AN, MR020AN, MR030AN, MR040AN, MR050AN, MR070AN, MR085AN

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

PACKAGED AIR COOLED Product Data Catalog

VersaTemp Water-to-Water Heat Pump with Auxiliary Air-Cooled Coil. Product Data Catalog. ARA 020X, 030X, 060X Modules. Water-to-Water Heat Pumps

Virtual Moveable Endcap II (VME II ) Product Catalog For Heat Recovery Applications

Air-Cooled Modular Split Systems. Product Data Catalog

Air-Cooled Stand-Alone ASC Chillers 20 thru 195 Tons

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Water Cooled MagLev Compact Centrifugal Modular Chiller. Product Data Catalog MS-080F, MS-100F

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

MAC N-407 Air-Cooled Chiller

Dedicated Heat Recovery Chiller (DHRC) Product Data Catalog for R410A and R134a Refrigerants. Includes: MS010XC-410A

Stand-Alone Water-Cooled ProcessChillers

MS010AN1-134a. MS050AN1-134a MS015XC1-410A. MS015AN1-134a. MS070AN1-134a MS020XC1-410A. MS020AN1-134a. MS105AN1-134a MS030XC1-410A.

MACH N-407 Heat Pump Air-Cooled Chiller

Cutting Edge Compressor Technology

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

C13-Series Engineering Guide

.2 Section Waste Management and Disposal.

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Submittal. Date: September 04, Customer P.O. Number: Customer Project Number:

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Call us today! (800)

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Call us today! (800)

Call us today! (800)

Air-Cooled MagLev Chiller Product Catalog

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

MAC-120HE-03 Air-Cooled Chiller

sm All Product Catalog

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

THE FOLLOWING CHANGES/ADDITIONS TO THE ABOVE CITED SOLICITATION ARE ANNOUNCED:

OACS Outdoor Air-Cooled Central Chillers

Liebert CSU3000 Chiller

VertiCool Aurora Engineering Guide

Air-Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

VariCool VAV Engineering Guide

Central Chillers TS Series

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

Commercial High-Efficiency Condensing Units

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

30GN FLOTRONIC II AIR-COOLED CHILLERS

Commercial High-Efficiency Condensing Units

SMALL AIR COOLED CONDENSERS

NQ Series Portable Chillers

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

Air-Cooled Condensing Units with Compact Screw Compressors

NEW CHILLER SCHEDULE

SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule #

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

SCROLL COMPRESSORS TYPE AIR COOLED PACKAGE CHILLERS

Precise Temperature Control; Compact Footprint

Unit Dimension. Unit Nomenclature DEHUMIDIFIER NOMENCLATURE UNIT VOLTAGE: 2: 240/1/60 5: /3/60 9: 480/3/60 8: 600/3/60

RECORD SUBMITTAL COVER SHEET

Air-Cooled Split System Condensing Units for Remote DX Coils and Air Handlers. Models RCS 015D to 140D R-410A Refrigerant.

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

30GT FLOTRONIC AIR-COOLED CHILLERS

GUIDE SPECIFICATIONS. WW Series Water-to-Water Reverse Cycle Chillers & Low Temp Boilers. WW Reverse Cycle Chillers / Low Temperature Boilers

Submitted to Reference Approval Construction Unit Designation Schedule #

DOLPHIN RADIATOR & COOLING SYSTEMS P.O.Box: 1424,Ph#: , Fax#: ,

Wicomico County Purchasing 125 N. Division St. Room B-3 Salisbury, MD Ph Fax Addendum # 1

Aquaflair TRAC-TRAF-TRAH

Product Chillers A P P L I C AT I O N S

SECTION ROTARY-SCREW WATER CHILLERS

Air-Cooled Global Chiller

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

LC Series Chillers. Engineering Catalog. Air-Cooled Condenser

Water-Cooled Self-Contained Units

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

GUIDE SPECIFICATIONS AQUARIUS ii

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Next-Gen Uni-Pak 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

ENGINEERING SPECIFICATIONS

ENGINEERING SPECIFICATIONS

CoolSpot Engineering Guide

water to water heat pumps

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

Air cooled industrial chillers

Product Data. GEMINI SELECT 09DPS ,09DPM Air-Cooled Condensers with PURON Refrigerant (R-410A) 50/60 Hz

150 & 200 RT MG-SERIES GAS FIRED DOUBLE-EFFECT EFFECT ABSORPTION CHILLER-HEATER

SECTION AIR COOLED WATER CHILLERS (LESS THAN 150 TONS)

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

WCH5**4. Product Specifications

MODELS LIST. Nominal Capacity RT

Submitted to Reference Approval Construction Unit Designation Schedule #

MODELS W1LC220, 260 AND 320 STYLE B

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

Transcription:

For Modules: ASM002X, ASM003X, ASM005X, ASM008X, ASM010X, ASM015X, ASM020X, ASM030X Air Cooled Medical Chiller Product Data Catalog

Product Introduction Multistack products are ideal for many mission critical and high-tech applications such as data centers, linear accelerators and industrial processes. They re also a good choice for medical applications including MRI and surgical suites. Multistack Model ASM medical chillers are designed from the ground up with reliability, redundancy, quality and efficiency. Three through 30-ton capacities in standalone non-modular configurations Available with single- and dual-refrigeration circuits. 7 mm micro-groove condenser coils. Electronic expansion valves provide precise control, reliable operation Variable speed scroll compressors available in some sizes for precise leaving temperature control EC fan motors with latest fan blade technology Microprocessor, non-proprietary controls interoperable with all major control protocols Thermal dispersion proof-of-flow Web-based remote monitoring and diagnostics Available in all stainless steel construction, stainless steel components, or with epoxy paints and coil coatings Model Number Nomenclature ASM 030 X C/N 1 1 H A L 1 A A A E S S -410A Refrigerant Tank 8 Pump 7 Fan Configuration 6 Condenser Coating 5 Condenser 4 Evaporator 3 AHRI Version Ambient ( L - Low, S - Standard, H - high, C - low & high) Application 2 Voltage (see voltage codes) Frame Designation 1-32 x 58, 2-36 x 72, 3-36 x 84, 4-72 x 84, 5 - other) No. of Refrigerant Circuits ( 1 - single, 2 - dual, 4 - four) AHRI Certified (C - certified, N - Not certified) Compressor Type 1 Module Nominal Capacity (003-030 tons, needs 3 digits) Series 2 X - Copeland Scroll (ZP), A - Copeland Scroll (ZR), D-Copeland Digital Scroll, N - none, Q - quasi variable speed Copeland, V - true variable speed Copeland) 3 A - Air Cooled, C - Remote Condenser, D - Cond Unit, H-Heat Recovery, R - Heat Pump (ASA and ARA are H - heat recovery) 4 A - Brazed SS, B - Brazed SMO, C- S&T copper, D - S&T cu-ni, O - remote by others,r-remote by MS, V - Other, N-None 5 A - Cu tube Al fin, B - Cu tube Cu fin, C- Microchannel, V - Other 6 A - None, B - Bronzeglow, H - Heresite, E - Electrofin, S - Standard, V - Other 7 E-ECM Fan, H - High static, L -Single Fan, S - standard, V -Other 8 A - brazed SS, B - brazed SMO, E - double wall brazed, N - none, V - other 9 R-410A, R-134a, 407c 3 3

General Data General Data Table of Air Cooled Standard X Modules with a Single Compressor Compressor ASP002 ASM003 ASP005 ASP008 ASP010X Type SCROLL Nominal Capacity (per compressor) 2 3 5 7.5 10 Quantity 1 1 1 1 1 Evaporator ASP002 ASM003 ASP005 ASP008 ASP010X Type BRAZED PLATE Weight 11 11 17 22 31 Evap Water Storage (gallons each) 0.2 0.2 0.5 0.7 1.1 Quantity 1 1 1 1 1 Condenser Fans ASP002 ASM003 ASP005 ASP008 ASP010X Motor Type EC kw.25.25.75 2.0 3.0 Quantity 1 1 1 1 1 Fan Type Axial Fan Material Aluminum Air Flow (cfm) (per module) 2,000 3,000 5,000 7,500 7,500 Condenser Coils* ASP002 ASM003 ASP005 ASP008 ASP010X Fin Material Aluminum Tube Material Copper Tube Diameter (in.) 7 mm Number of Rows 4 4 4 4 4 Coil Dimensions (Quantity) 42 x 30 42 x 30 42 x 30 42 x 40 42 x 40 Tank ASP002 ASM003 ASP005 ASP008 ASP010X Material 304 Stainless Steel Nominal Capacity (gallons) 20 40 40 60 60 Pump ASP002 ASM003 ASP005 ASP008 ASP010X Material 316 Stainless Steel HP 1.5 2 2 2 2 Refrigerant Type R410A Charge (lbs./circuit) Number of Circuits 1 1 Figure 1 1 1 1 4 4

General Data General Data Table of Air Cooled Standard X Modules with Two Compressors Compressor ASP008X ASM010X ASP015X ASP020X ASP030X Type SCROLL Nominal Capacity (per compressor) 3.25 5 7.5 10 15 Quantity 2 2 2 2 2 Evaporator ASP008X ASM010X ASP015X ASP020X ASP030X Type BRAZED PLATE Weight 22 46 60 75 Evap Water Storage (gallons each) 0.7 0.9 1.4 1.9 Quantity 1 1 1 1 1 Condenser Fans ASP008X ASM010X ASP015X ASP020X ASP030X Motor Type EC kw 2.0 3.0 2.0 5.0 6.0 Quantity 1 1 1 1 1 Fan Type Axial Fan Material Aluminum Air Flow (cfm) (per module) 10,000 10,000 11,000 16,000 22,000 Condenser Coils* ASP008X ASM010X ASP015X ASP020X ASP030X Fin Material Aluminum Tube Material Copper Tube Diameter (in.) 7 mm Number of Rows 6 6 6 6 6 Coil Dimensions (Quantity) 42 x 40 42 x 40 42 x 60 42 x 60 42 x 78 Tank ASP008X ASM010X ASP015X ASP020X ASP030X Material 304 Stainless Steel Nominal Capacity (gallons) 60 60 100 100 120 Pump ASP008X ASM010X ASP015X ASP020X ASP030X Material 316 Stainless Steel HP 1.5 2 2 2 2 Refrigerant Type R410A Charge (lbs./circuit) Number of Circuits 2 2 2 2 2 5 5

Pressure Drop/Electrical Information Evaporator Pressure Drop Pressure Drop - Feet of Water 10 A - ASM002/ASM003 B - ASM005 C - ASM008 D - ASM010X E - ASM015X/ASM020X F - ASM030X 1 1 10 100 1000 Unit Water Flow - GPM ELECTRICAL DATA Model RLA per Compressor FLA per Fan Motor FLA per Pump Number of Number of 3 phase 1 phase 3 phase 1 phase Pump HP 3 phase 1 phase Compressors Fan Motors 208/460/575V 230V 208/460/575V 230V 208/460/575V 230V ASM002X 1 7.9/3.6/2.9 10.6 1 10.6/9.6/TBD 3.5 1.5 6.6/3/2.4 10.0 ASM003X 1 11.6/5.3/4.2 15.3 1 10.6/9.6/TBD 3.5 2 7.5/3.4/2.7 12.0 ASM005X 1 17.5/7.9/6.4 25.9 1 10.6/9.6/TBD 3.5 2 7.5/3.4/2.7 12.0 ASM008X 1 26.2/12.1/9.8 N/A 1 10.6/9.6/TBD N/A 2 7.5/3.4/2.7 12.0 ASM008X 2 13.5/6.1/4.8 18.2 1 10.6/9.6/TBD 3.5 2 7.5/3.4/2.7 12.0 ASM010X 1 19.5/8.7/7.2 N/A 1 10.6/9.6/TBD N/A 2 7.5/3.4/2.7 12.0 ASM010X 2 17.5/7.9/6.4 25.9 1 10.6/9.6/TBD 3.5 2 7.5/3.4/2.7 12.0 ASM015X 2 26.2/12.1/9.8 N/A 2 10.6/9.6/TBD N/A 3 10.6/4.8/3.9 17.0 ASM020X 2 34.3/16.2/12.5 N/A 2 10.6/9.6/TBD N/A 5 16.7/7.6/6.1 28.0 ASM030X 2 55.0/26.0/21.0 N/A 2 10.6/9.6/TBD N/A 5 16.7/7.6/6.1 28.0 WIRING SIZING (MCA= MINIMUM CIRCUIT AMPACITY) MCA = (1.25 x RLA1*) + RLA2 + RLA3 FUSE SIZING (MFS = MAXIMUM FUSE SIZE) MFS = (2.25 x RLA1*) + RLA2 + RLA3 Where MFS does not equal a standard size fuse, the next larger fuse should be used. NOTES: 1. Compressor Rated Load Amps (RLA) are based on 125 F Saturated Condensing Temperature. 2. *RLA1 = RLA of the largest motor in the system. RLA2 & RLA3 = RLA of other motors in the system. 3. Wire sizing is based on Nat. Electr. Code (NEC)rating for 75 C wire, with 3 wires per conduit. 4. Wiring distance from branch circuit shall not exceed 100 feet. MCA WIRE SIZE (AWG) 75 (3 Conductors/1Conduit) 50 8 65 6 85 4 100 3 115 2 130 1 150 1/0 175 2/0 200 3/0 230 4/0 255 250 MCM 285 300 MCM 310 350 MCM 335 400 MCM 380 500 MCM 420 600 MCM MCA WIRE SIZE (AWG) 75 (6 Conductors/2Conduit) 510 250 MCM 570 300 MCM 620 350 MCM 670 400 MCM 760 500 MCM 800 600 MCM 6

Chiller Drawings ASM003-ASM0055 - Ton Chiller 7 7

Chiller Drawings ASM008-ASM010 - Ton Chiller 8 8

Chiller Drawings ASM015-ASM020 - Ton Chiller 9 9

Chiller Drawings ASM030 - Ton Chiller 10 10

Mechanical Specifications AIR-COOLED PACKAGED CHILLER GUIDE SPECIFICATION(ASM) SECTION 15400 MECHANICAL CHILLER PART 2 PRODUCTS 2.01 Operating Conditions A. Provide outdoor packaged air-cooled liquid chiller with the capacity as scheduled on drawings at job site elevation listed in Section 15050. B. Chiller shall be designed to operate using R-410a Refrigerant. C. The liquid to be chilled will be water containing corrosion inhibitors and antifreeze solution as required. D. Chiller shall be designed to operate using volt, 3 phase, Hz electrical power supply. 2.02 Outdoor Packaged Air-Cooled Chiller A. Approved manufacturer is AIRSTACK or approved equal. Note: There will be no deviation to system design or material choices. All manufacturers must comply with design criteria. Substitutions are not acceptable. In the event that submitted equipment is deemed non compliant the contractor shall provide at no additional expense to the owner/client equipment that is compliant with specification. B. System Description: Chiller shall incorporate a Scroll type Compressor(s) and consist of a single independent refrigerant circuit. Each refrigerant circuit shall consist of an individual compressor(s), evaporator, electronic expansion valve, liquid line solenoid valve, filter drier, fin and tube condenser, and control system. The entire system shall be mounted on a heavy steel base. C. General 1. Chiller Modules shall be ETL listed in accordance with UL Standard 1995, CSA certified per Standard C22.2#236. 2. System shall ship wired and charged with refrigerant and shall be factory run tested prior to shipment. 3. Compressor, heat exchanger, piping and controls shall be mounted on a heavy gauge steel frame. Electrical controls, contactors, and relays for each system shall be mounted within the system cabinet. D. Evaporator: Each evaporator shall be a brazed plate heat exchangers constructed of 316 stainless steel; designed, tested, and stamped in accordance with ASME code for 400 psig water-side working pressure. Evaporator heat exchanger shall not be mounted above the compressor, to prevent the effect of migration of refrigerant to the cold evaporator with consequent liquid slugging on start-up. E. Compressor: Each chiller shall contain one (two) hermetic scroll compressors mounted to the chiller with rubber-in-shear isolators. Each system also includes high discharge pressure and low suction pressure safety cut-outs. F. Condenser: Each chiller shall contain a single fan. Blades are aluminum construction owlet design 7-blade axial fan with integral EC motor (direct drives with external VFD driven motors are not acceptable). Efficiency exceeds criteria set out in the ErP 2015 directive. Individual fans are factory tested. Encapsulation required. Encapsulation is a process of filling a complete electronic assembly with a solid compound for resistance to shock and vibration, and for exclusion of moisture and corrosive agents. Fan motors shall all be pressure controlled and suitable for outdoor use. Condenser coils shall be finned tube design. Coil shall be constructed using copper tubes and aluminum fins with integral subcooling. G. Central Control System. 1. Chiller shall have microprocessor based controls. System shall include entering chilled water control and provide head pressure control for the condenser fan. 2. Safeties shall include low leaving chilled water temperature safety for freeze protection. H. Refrigerant circuit shall include all refrigerant specialties to provide reliable operation down to 40 F Ambient. OPTIONAL: LOW AMBIENT TO -20 F Chiller shall incorporate appropriate refrigerant specialties including a properly sized refrigerant receiver and flooded head pressure control valves for operation to -20 F. 11

Mechanical Specifications I. Chiller shall be provided with a single point power connection. J. PUMP Provide integral chilled water Pump of size and capacity indicated on the drawings and schedules. Pump shall be a single centrifugal pump. Pump impeller shall be stainless steel. Pump housing shall be constructed of stainless steel. Pump starters and controls shall be provided. In addition, in the event of a loss-of-flow failure of the chilled water system, the system shall shut down and provide a failure output. OPTIONAL: DUAL PUMPS Dual pumps shall be provided for N+1 redundancy. In the event of a pump failure the back-up pump shall automatically be enabled.. K. TANK An integral 20 (40, 60, 100, 120) -gallon stainless steel chilled water tank shall be provided integral to the system piping. Tank shall be pressure rated at 125 psi minimum. 2.03 SAFETIES, CONTROLS AND OPERATION A. The chiller safety controls shall be provided (minimum) as follows: 1. Low evaporator refrigerant pressure 2. Loss of water flow through the evaporator 3. High condenser refrigerant pressure 4. High compressor motor temperature 5. Low suction gas temperature 6. Low leaving evaporator water temperature B. Failure of chiller to start or chiller shutdown due to any of the above safety cutouts shall enable a fault output from the integral controls system. C. The chiller shall be furnished with a Master Controller as an integral portion of the chiller control circuitry to provide the following functions: 1. Provide automatic chiller shutdown during periods when the load level decreases below the normal operating requirements of the chiller. Upon an increase in load, the chiller shall automatically restart. 2. Provisions for connection to automatically enable the chiller from a remote energy management system. D. Normal Chiller Operation 1. When chiller is enabled, the factory supplied Master Controller modulates the chiller capacity from minimum to maximum as required by building load. 2. The Chiller control system shall respond to Entering Water Temperature and will have an integral reset based on entering water temperature to provide for efficient operation at part-load conditions. PART 3 INSTALLATION 3.01 PIPING SYSTEM FLUSHING PROCEDURE A. Prior to connecting the chiller to the building chilled water loop, the piping shall be flushed with a detergent and hot water (110-130 F) mixture to remove previously accumulated dirt and other organic residue. In old piping systems with heavy encrustation of inorganic materials consult a water treatment specialist for proper passivation and/or removal of these contaminants. B. During the flushing a 30 mesh (max.) Y-strainers (or acceptable equivalent) shall be in place in the system piping and examined periodically as necessary to remove collected residue. The use of on board chiller strainers shall not be acceptable. The flushing process shall take no less than 6 hours or until the strainers, when examined after each flushing, are clean. Old systems with heavy encrustation shall be flushed for a minimum of 24 hours and may take as long as 48 hours before the filters run clean. Detergent and acid concentrations shall be used in strict accordance with the respective chemical manufacturers instructions. After flushing with the detergent and/or dilute acid concentrations the system loop shall be purged with clean water for at least one hour to ensure that all residual cleaning chemicals have been flushed out. C. Prior to supplying water to the chiller the Water Treatment Specification shall be consulted for requirements regarding the water quality during chiller operation. The appropriate chiller manufacturer s service literature shall be available to the operator and/or service contractor and consulted for guidelines concerning preventative maintenance and off-season shutdown procedures. 12 12

Mechanical Specifications 3.02 Water Treatment Requirements A. Supply water for the chilled water circuit shall be analyzed and treated by a professional water treatment specialist who is familiar with the operating conditions and materials of construction specified for the chiller s heat exchangers, headers and associated piping. Cycles of concentration shall be controlled such that recirculated water quality for modular chillers using 316 stainless steel brazed plate heat exchangers and carbon steel headers is maintained within the following parameters: 1. ph Greater than 7 and less than 9 2. Total Dissolved Solids (TDS) Less than 1000 ppm 3. Hardness as CaCO3 30 to 500 ppm 4. Alkalinity as Ca CO3 30 to 500 ppm 5. Chlorides Less than 200 ppm 6. Sulfates Less than 200 ppm 3.03 Warranty and Start-Up A. Manufacturer s Warranty: Manufacturer shall provide full parts-only warranty coverage for entire chiller for a period of one year. All parts shall be wa ranted against defects in material and workmanship. Similar parts-only coverage shall be provided for the chillers compressors for a period of five years. The warranty period shall commence either on the equipment start-up date or six months after shipment, whichever is earlier. B. Manufacturer shall provide the services of a Factory Authorized Service Engineer to provide complete start-up supervision. Factory Authorized Service Engineer shall also be responsible for assembly of the chillers cabinetry package and electrical bus bar system. After start-up a Manufacturer s Representtive shall provide a minimum of 8-hours of operator training to the owner s designated representative(s). 13 13

1065 Maple Avenue P.O. Box 510 Sparta, WI 54656 Phone 608-366-2400 Fax 608-366-2450 www.multistack.com F1560514