VA G 052 S

Similar documents
VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

VA G 052 S VA08 Indoor Model 1200, 1500 and 2000 Watts. Sealed Enclosure Cooling Air Conditioners

G /6000 BTU/Hr. 1172/1758 Watt. Specifications. Finish. Notes

SPECTRACOOL INDOOR/OUTDOOR

N Volt 1800 BTU/Hr. 527 Watt

N Volt 1800 BTU/Hr. 527 Watt. Specifications. Finish. Notes

SPECTRACOOL Indoor & Outdoor Air Conditioners

SPECTRACOOL Indoor & Outdoor Air Conditioners

Indoor and Outdoor Enclosures Outdoor Nema 3, 3R, 4, 4X Cabinet Enclosures LTE 4G Wimax Telecom Security Traffic

5736 N. Michigan Road Indianapolis, IN 46228

GENESIS Indoor Air Conditioners

5736 N. Michigan Road Indianapolis, IN 46228

T BTU/Hr. 234 Watts. T BTU/Hr. 586 Watts. Air Conditioners

N Volt 1800 BTU/Hr. 527 Watt

G /6000 BTU/Hr. 1172/1758 Watt

Top-Mount Air Conditioners

G /6000 BTU/Hr. 1172/1758 Watt

PROAIR Harsh Environment/Wash Down Air Conditioners

CHAPTER12. Thermal Management. Featured Products in this Chapter. Outdoor Air Conditioners T15, T20 and T29 Series 800-4,000 BTU/Hr. P.

Quality Enclosures. Service Excellence.

Featured Products in this Chapter. Subject to change without notice PH FX hoffmanonline.com 2010 Pentair Technical Products

Thermal Management INDEX. Management. Thermal TM-1

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

Construction. Electrical. Enclosure Protection IS19 - Industry Standards UL Recognized Type 3, 3R, 4 & 12 IEC IP56

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

CDS 80. Continuous ventilation without dehumidification can be selected on the CDS 80 control panel.

Wall-Mount Cabinets. Pretreated steel coated with light-gray, low-gloss, lightly textured RAL 7035 polyester powder

Wall-Mount Cabinets. Pretreated steel coated with light-gray, low-gloss, lightly textured RAL 7035 polyester powder

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Order from Cuny & Guerber Inc., 2100 Kerrigan Ave., Union City, NJ USA Phone: web:

CENTRAL SPLIT UNIT UNIC

Quality Products. Service Excellence.

Condensing Units CUS 15-60

MAC N-407 Air-Cooled Chiller

SEALED ENCLOSURE COOLING

Quality Enclosures. Service Excellence.

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

MACH N-407 Heat Pump Air-Cooled Chiller

Air Conditioning THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

AA-480-XX OUTDOOR THERMOELECTRIC COOLER ASSEMBLY USER S MANUAL

Service Parts for RMR Wall-Mount Enclosures

Ambient (ºF) Temperature Rise Above

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

SPXA / SPXA-HP Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

Description. Applications

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

Ruud Achiever Series Air Conditioners

Klimaire 16 SEER CENTRAL DUCTED YEAR. Central Air Conditioning & Heat Pump Systems Multi Position Air Handling Units LIMITED GUARANTEE

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

30GT FLOTRONIC AIR-COOLED CHILLERS

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

Microchannel REMOTE AIR COOLED CONDENSER WITH ELECTRONICALLY COMMUTATED AXITOP MOTORS. Technical Bulletin. Products that provide lasting solutions.

RACK-MOUNT Air Conditioners

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Split System Cooling Product & Performance Data

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

SPXB / SPXB-HP Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Multi Inverter Air Conditioning Condensing Units - Summary

R407C Cellar Cooling. Fansets: Single phase, high efficiency, low

Technical Data Ducted Three Phase Split System Air Conditioner

TOP 29 QUESTIONS PROSPECTIVE ENCLOSURE COOLING THERMAL EDGE CUSTOMERS ASKED BY Thermal Edge, Inc

Technical Data OPA 101, 150, 180. Ducted Three Phase Packaged Air Conditioner kw 18.5 kw. Extra Long Life Epoxy Coated Outdoor Coil

TOUCH-SAFE HEATERS INDUSTRY STANDARDS

INSTRUCTION MANUAL. SPECTRACOOL Slim Fit Air Conditioners. All Models

maintenance should only be performed by a trained, qualified person. Consumer service is recommended only for filter replacement.

Comfort. Description. Applications

T-Series Air Conditioner T15 Model

High Ambient / High Efficiency Series. R - 410a. 50Hz. Ducted Split Air Conditioners (5.0 kw kw)

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

FRIGIDAIRE PTAC COLLECTION AIR CONDITIONERS

Commercial High-Efficiency Condensing Units

30GN FLOTRONIC II AIR-COOLED CHILLERS

Safe Enclosure Cooling

TC-5231 Series, TC-5232, & TC-5241 Series

Wall-Mount Cabinets PROTEK Single-Door and Double-Hinged Cabinets

ADD-ON AIR CONDITIONING CHANGING THE GAME FOR COMFORT AND PERFORMANCE

DUCTED SPLIT AIR CONDITIONERS 50Hz GCUN/GDS SERIES R 407C

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

Condensing Units & Air Handlers

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES

KPHE24 SERIES WATER-TO-AIR HEAT EXCHANGER

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

FTTX FIBER OPTIC CABINET PACKAGE, TYPE 4X

13 GEP A L P - 1 A

Product Data. Features/Benefits These dependable split systems match Carrier s indoor-air handlers and directexpansion

Packaged Terminal Air Conditioner (PTAC)

Split System Cooling Product Data

AMERICAN STANDARD 14 MODELS 4A7B E

SABIANA ENVIRONMENTAL COMFORT. Air Conditioning Ceiling Air Conditioning Elegant

FIGURE 1 Forced Convection Method. Filter & Grille Required. Ambient Air. Filter & Grille Required

SPECIFICATION FOR APPROVAL

Transcription:

763.576.3200 SPEC-00746 D763.422.2211 COOLING SEALED ENCLOSURE COOLING AIR CONDITIONERS Sealed Enclosure Cooling Air Conditioners V-SERIES COMPACT AIR CONDITIONERS VA06 Indoor Model 400 and 600 Watts INDUSTRY STANDARDS IP 56 Internal Air Loop IP 34 External Air Loop CE GOST APPLICATION Industrial drive enclosures Automotive assembly systems Packaging equipment Material handling Other process control systems FEATURES Coated coils for filterless operation in most manufacturing environments Convenient quick-fastening terminal block for easy power connections Built-in installation hooks on the back of the unit Unique passive condensate management system Indoor operating temperature range from 20 C to 55 C IP 56 protection against dust and water infiltration Reliable mechanical thermostat to reduce the chance of failure Digital display and malfunction switch optional All-metal shroud for rugged factory conditions Exterior surface mounting standard Partial recessed mounting options Full-size cutout print included with every unit Easy access to the optional aluminum filter and other components Rigorously tested to withstand shipping vibration, high temperatures and other operating challenges Every unit functionally tested prior to leaving the factory R134A earth-friendly refrigerant and RoHS compliant Outdoor AC models also include: - Malfunction Switch - Compressor heater - Compressor head pressure control - Enclosure heater 2000W - Corrosion resistant components - Operating temperature range -40 C - 55 C SPECIFICATIONS 400 and 600 nominal watts 230 VAC 50 Hz power input with +/-10 percent operating range CE and GOST certifications FINISH RAL 7035 light-gray, semi-textured powder-coat paint standard Other colors and textures available upon request Model Number Structure VA 06 06 25 G 052 S 1 2 3 4 5 6 7 1. Identifies the of air conditioner type, VA=V Series Air Conditioner. 2. Identifies the approximate height, 06=508mm to 600mm. 3. This is the air conditioner s nominal capacity in Watts, 06=600 W. 4. Identifies the input power of air conditioner, 2=220V/230V, 5=50Hz. 5. Identifies the construction material and refrigerant of air conditioner, G=Galvanized sheet metal and R134a. 6. Unique set of numbers for each air conditioner which identifies the accessories on a model, 052=Indoor, Terminal block and finger guard. 7. S=Standard product. NOTES Visit www.mcleancoolingtech.com to download 2D and 3D CAD drawings into the design of your electronics system. 1 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION

Performance Data 400 W, 600 W MODEL NUMBER Indoor Model VA060325G052S VA060625G052S Indoor Model Partial Recessed Mount VA060325G053S VA060625G053S Indoor Model with Display and VA060325G059S VA060625G059S Malfunction Switch COOLING PERFORMANCE: Nominal: L35 L35 Watt 400 590 L35 L50 Watt 310 510 Refrigerant R134a R134a Refrigerant Charge (g) 100 150 Operating Temperature Range: Maximum ( C) 55 55 Minimum ( C) 20 20 Airflow at 0 Static Pressure: Internal loop (m 3 /h) 115 180 External loop (m 3 /h) 325 270 Duty Cycle 100% 100% ELECTRICAL DATA Rated Voltage 230 230 Frequency (Hz) 50 50 Operating Range +/-10% +/-10% Max. Power Consumption L35 L35 225 420 (Watt) Max. Power Consumption L35 L50 285 505 (Watt) Max. Nominal Current (Amp) 1.5 2.8 Starting Current (Amp) 7 16 Pre-fuse T (Amp) 10 10 Agency Approvals CE GOST CE GOST Power Input Description Terminal Block Terminal Block PERFORMANCE FACTOR L35 L35 Cooling Performance (Watt)/ 1.8 1.4 Power Consumption (watt) PERFORMANCE FACTOR L35 L50 Cooling Performance (Watt)/ 1.1 1.0 Power Consumption (watt) ENCLOSURE PROTECTION IP Code IP 56 Internal loop IP34 External loop IP 56 Internal loop IP34 External loop CONTROLLER Description Basic Mechanical Thermostat Basic Mechanical Thermostat Thermostat Location Enclosure Side Enclosure Side Factory Thermostat Setting ( C) 35 35 SOUND LEVEL At 1 M 64 dba 72 dba UNIT CONSTRUCTION Material Galvanized Sheet Metal Standard Galvanized Sheet Metal Standard Finish RAL 7035 light-gray, semi-textured powder-coat paint standard RAL 7035 light-gray, semi-textured powder-coat paint standard UNIT DIMENSIONS Height (mm) 508 508 Width (mm) 270 270 Depth (mm) 252 252 Weight (kg) 23 25 EQUIPMENT PROTECTION PH 763.422.2211 FAX 763.576.3200 HOFFMANONLINE.COM Cooling 2

Performance Curves for 400 and 600 Watt Models VA060325GXXXS 400 Watt Capacity Curves 230V/50Hz 700 650 600 550 500 Capacity (Watts) 450 400 350 300 250 200 150 100 50 20 25 30 35 40 Ambient Temp ( C) 45 50 55 60 VA060625GXXXS 600 Watt Capacity Curves 230V/50Hz Capacity (Watts) 850 800 750 700 650 600 550 500 450 400 350 300 250 20 25 30 35 40 45 50 55 60 Ambient Temp ( C) 3 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION

VA06 V-Series Compact Note: 1. Mounting gasket supplied (not shown) 2. Units: mm 89084470 CUTOUT DIMENSIONS EXTERNAL SURFACE MOUNTING EQUIPMENT PROTECTION PH 763.422.2211 FAX 763.576.3200 HOFFMANONLINE.COM Cooling 4

VA06 V-Series Compact Partial Recess 331 270 AMBIENT AIR OUT ENCLOSURE AIR IN THERMSTAT ADJUSTMENT POWER INPUT 569 508 REMOVABLE HANGING TABS AMBIENT AIR IN ENCLOSURE AIR OUT MOUNTING BOLTS(14) 251 75 89104637 CLEANABLE,REUSABLE ALUMINUM INLET FILTER SLIDS OUT SLOT IN BOTTOM OF FRONT COVER. Note: 1. Mounting gasket supplied (not shown) 2. Units: mm 10 302 260 ACCESS HOLE TO 9.6mm O.D DRAIN STUB 130 518 130 282 130 64 26 486 538 13(4x ) 6.5(14x ) CUTOUT DIMENSIONS RECESSED MOUNTING 5 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION

Notes EQUIPMENT PROTECTION PH 763.422.2211 FAX 763.576.3200 HOFFMANONLINE.COM Cooling 6