AAF Herman Nelson. Classmate Conventional Unit Ventilators. AH AV Vintage C

Similar documents
McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

McQuay. Self-Contained Unit Ventilator. UAZQ, UAZR, UAZU Design G (7) Replacement Parts List No Revision D 08/2018

Daikin. Self-Contained Unit Ventilator. UAEQ 036, 044, 054 Design H (8) Replacement Parts List No New 11/2017

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

McQuay. Unit Ventilators Self-Contained UAED, UAEQ, UAER, UARQ, UERQ, UAZQ, UAZR, UAZS, UAZU, UAZV Designs D (4), E (5)

AAF Herman Nelson. Self- Contained Unit Ventilator AE, AR, AZ 2-7. Last Manufactured: Replacement Parts List No Revision F 09/2017

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 007, 009, 012 Design 1. Replacement Parts List No Revision M 11/2017

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision O 11/2017

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision R 11/2018

McQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993

McQuay. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. WCDD, WCDE, WCMG Design A (1) WCDD, WCDE Design B (2)

McQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994

Daikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988

McQuay. Seasonmaker ThinLine Horizontal Fan Coil. TSH, TSC Vintage F. FTSH, FTSC Designs A(1), B(2) Last Manufactured: 2008

AAF. Fan Coil XR 1-9. Last Manufactured: Replacement Parts List No Revision B 07/2001

McQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E

Air Cooled Scroll Compressor Condensing Unit

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 020, 025 Vintage E. Replacement Parts List No Revision J 02/2018

MicroTech Unit Ventilator

McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage A. Replacement Parts List No Revision E 04/2016

McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage G. Replacement Parts List No Revision C 09/2018

Job Name Control Systems Description Date

Climate Control Singer. Incremental Comfort Systems. KS, EKS Vintage B. Last Manufactured: 1982

Daikin McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage B. Replacement Parts List No Revision F 11/2017

McQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007

McQuay. Applied PTAC Air Conditioner and Heat Pump PDAC, PDAA, PDAE, PDAN, PDAF PDHP, PDHA, PDHE, PDHF Design 1

K*ES120 DESCRIPTION TECHNICAL GUIDE SPLIT-SYSTEM EVAPORATOR BLOWERS 10 NOMINAL TONS EER 8.5 ACCESSORIES FIELD INSTALLED TABLE 1: ARI RATINGS*

SPLIT-SYSTEM EVAPORATOR BLOWERS K2EU060, K4EU090, K3EU120 & K1EU180 5 Thru 15 Nominal Tons DESCRIPTION ACCESSORIES FIELD INSTALLED

McQuay. Aircon Air Cooled Condenser. AMB, APB AMD, APD Vintage A. Last Manufacture: 1978

Daikin McQuay. Applied PTAC Air Conditioner and Heat Pump. PDAA, PDAE, PDAF, PDAN, PDHA, PDHE, PDHF Design 3

Catalog ThinLine Horizontal Fan Coils. Type FCHC, FCHH and FCHR. Exposed Horizontal Cabinet. Recessed Horizontal Cabinet

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

Operation & Maintenance Manual

AAF HermanNelson. UniVent Unit Ventilator ZY, AZY, BZY, CZY. Last Manufactured: Replacement Parts List No Revision E 09/2005

Vertical V*B Series Fan Coil Technical Catalog

Catalog ThinLine Horizontal Fan Coils. Type FCHC, FCHH and FCHR. Exposed Horizontal Cabinet. Recessed Horizontal Cabinet

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

control sequences model QST / EST Series Table 47: QST / EST Analog Electronic Control Strategies Fan Powered Air Terminals

FCC Fan-Coil Units High-Performance, Vertical

Catalog Daikin Classroom Unit Ventilators. Models AHF, AHB, AHV and AHR Ceiling Units. AH Unit

CHAMPION SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L2EU NOMINAL TONS

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

Technical Guide DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS. 7-1/2 and 10 NOMINAL TONS LA090 & LA120 SUPPLY AIR PLENUMS

Catalog ThinLine Vertical Fan Coils. Type FCVC, FCVH, FCVS Vertical Design. Model FCVC. Model FCVS

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

AIR COMPACT. Air handling units. Ultra high performance USE RANGE DESCRIPTION

Gas-Fired Indoor and Outdoor Duct Furnaces

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating

Modular Supply Make-Up Air Unit

EMBASSY SERIES SINGLE PACKAGE AIR CONDITIONERS (WATER-COOLED) C2ED060, 090, 120 & 180 5, 7-1/2, 10 & 15 Nominal Tons

ISERIES VERTICAL AHU ENGINEERING SPECIFICATIONS

Submittal. RBVR Vertical Concealed Floor Mount FCU RBVR

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES - FIELD INSTALLED. K5EU090 and K4EU Hz 7.5 and 10 NOMINAL TONS SUNLINE 2000 (WORLD 50 HZ)

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

Field Start-Up Sheet Direct Fired Gas Equipment

VertiCool Aurora Engineering Guide

Catalog ThinLine Vertical Fan Coils. Type FCVC, FCVH, FCVS Vertical Design. Model FCVC. Model FCVS

Valedictorian - Vertical Unit Ventilator Models VFF and VFV April, 2012

Large Capacity Fan Coil Units Catalog Belt-Drive and Direct-Drive Cabinet and Hideaway Models

BCE4 PRODUCT SPECIFICATIONS ENHANCED AIR HANDLER WITH VARIABLE SPEED APPLICATION INSTALLATION CABINET COMPONENTS CONTROLS WARRANTY

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

PARTS LISTS GAS/T... 1 GAW... 3 GBS/T... 5 GES/T... 6 GFS/T... 8 GFW... 9

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

FAS Fresh Air Supply Units

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

KIC Air Curtains. Technical Guide

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

Daikin McQuay. Pathfinder Screw Compressor Air-Cooled Chiller 3 Circuit. AWS Vintage B Unit Revision 0B (Code 62)

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

Zone Control Panels. ZoZ one Product Catalog Page 3 ED3 SMZ4SW SMZAC SMZ3SW JTZHP

Digital Precise Air Control - DPAC

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

GAS FURNACES G20RE/ G20RXE EXISTING NEG ENGINEERING DATA EXISTING NEG. Typical Applications

Cooling/Heat Pump Convertible Air Handlers

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

VariCool VAV Engineering Guide

REPLACEMENT PARTS LIST

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

Specifications and Performance

Transcription:

Replacement Parts List No. 0575800 Revision R 0/206 AAF Herman Nelson Classmate Conventional Unit Ventilators AH 00-008 AV 00-006 Vintage C UAHB, UAHF, UAHR, UAHV 07-20 UAVB, UAVR, UAVS, UAVV 07-5 Design C (3) Last Manufacture: 200 To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

Contents About the Model Number Changes...2 Parts List Revision History...3-4 Nomenclature Serial Number... 5. Model Number AH, UAHB, UAHF, UAHR, UAHV... 5-7 Model Number AV, UAVB, UAVR, UAVS, UAVV... 8-0 Adapter Back Kits... External Cabinetry AV Cabinet... 2. AH Cabinet... 3 Fan Section- Motor and Fan Components... 4 Electric Heat Electric Heat Elements... 5 Electric Controls... 5 Coil Section...6-8 Damper Section Drain Pan, and Face & Bypass Damper Components... 9. OA & Room Air Damper Components... 20 Hydronic Valves and Actuators... 2 Controls PC Board- Main Controllers MicroTech M325... 22. Controls By Others... 22. Fuses, Relays, Switches and Time Clock... 23 Field Installed Accessories Filters... 24 Critical Parts List AH 00-008, UAHB, UAHF, UAHR, UUAHV 07-20... CPL AV 00-006, UAVB, UAVR, UAVS, UAVV 07-5... CPL2 About the Model Number Changes In 2005 the model numbering nomenclature for the Conventional Unit Ventilators changed: The AH "C" Vintage unit is now the UAHB Design "C" unit. The AV"C" Vintage unit is now the UAVB Design "C" unit. The unit's components did not change when the nomenclature did (a few engineering changes have taken place since this RPL was last issued, and the part number changes are noted). The complete model number nomenclature currently used has been added to this revision. Unless otherwise noted, all components listed in this revision apply to both the current and the original model numbered units. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 2

Parts List Revision History Revision Date Description A 08//97 Page 6; AV Top Discharge Grille (Bubble #2) part numbers corrected (all sizes). Page 4; AH Discharge Air Grille (Bubble #2) part numbers corrected (all sizes). B /3/97 Page 29; AV/AH Damper Section; Actuator - OA with Linkage (Bubble #) pn was 4EZB9324. AV/AH Damper Section; Actuator - FBP with Linkage (Bubble #2) pn was 4EZB9324. C 07/98 Page 39; corrected item #0 on 6 fan, 460V. D 05/99 Page 27 - Added description and part number for Auxillary Drain Pans. E 0/99 Added new Page 4 - AV Adapter Back Kits. This resulted in the re-numbering of all later pages. Page 4 - Added footnote for Filter Stop (Bub.# 8). Page 20 - Corrected part number for Bar Grille (Bub.#) for 6-fan units. Page 22 - Added Blower Assembly. Added column and information for Unit Size 008. Page 23 - Added Bub.# 0 to diagram. Added Motor Gasket part number and description. Page 29 - Updated pn's for Damper Stop, Rear (Bub. 7) on all sizes.added Seal Strip Gasket pn's, descriptions & footnote. Page 33 - Updated; pn's for Damper - RA (Bub.02) all sizes. Info for Shafts (Bub. & 2). Page 43 - Updated info& added foonote for Low Temp. T'Stat, DE Coil (Bub. 34). Added pn & description for Freezestat Clip. Page 48 - Updated pn for Transformer, Motor Speed (Bub.# 5) for 208V, 230V & 265V units. Page 50 - Updated information and added footnote for Fan Relay (Bub.# 74). F /99 Page 43 - Added Sampling Chamber Gasket and Sampling Chamber Screw. G 09/00 Page 4-3/Fan units; 2.875"Top only pn now 0565700, added new 28" Top Only #060059. 4/Fan units; 2.875"Top Only pn is now 05657002, added new 28" Top Only pn 060069. 5/Fan units; 2.875"Top Only pn is now 05657003, added new 28" Top Only pn 060079. 6/Fan units; 2.875"Top Only pn is now 05657004, added new 28" Top Only pn 060089. Page 6 - Tinnerman pn changed from 4NKE8447 to 4NKE7968. Page 8 - Bub #2 pn changed from GC0748 to GC045. Page 0 - Bub #4 part numbers ended in 0, now end in 02. Page 6 - Bub #2 pn changed from GC0748 to GC045. Page 40 - Bub #; 265/460/575V TB pn 4ECA8878 changed to 802007686, (9 instances). Page 4- Bub #; 265/460/575V TB pn 4ECA8878 changed to 802007686, (0 instances). Page 44 - Bub #53; pn 4EPC9056 changed to 06063080. Page 48 - Bub #52; pn 4EPC9056 changed to 06063080. H 08/0 Page 2-'Attaching Parts' screw pn was incorrect, the correct pn is 4SAD3732. I 0/02 Page 44 - Bub #66- Description changed from "Plug & Receptacle Combo to just 'Plug'. J 02/05 Page 22 - Fan Wheel (Plastic) is not included in the Blower Assembly. K 05/05 Page 0 - Bub 37 discharge plenum pn's changed as follows; 4 fan pn changed from 0753902 to 075390, 5 fan pn changed from 07532002 to 0753200, 6 fan pn changed from 075302 to 07530. L 05/ Reformat to CSIV. Changed title page to reflect new code sheet title-"uahx, UAVX". Page 2 Added Model Number Note. Pages 4-9 Add code sheets. Add CPL Page. M 0/2 Title Page & footer- Change title to AH, UAHB, UAHF, UAHR, UAHV and AV, UAVB, UAVR, UAVS, UAVV. N 09/3 Relinked all drawings. Numerous changes were made. Pages Deleted- Dataplate Location, Sheet metal deleted from External Cabinetry, Touch-up paint, Electrical Data & External Static Pressure Chart, and Diagrams. Delete all Unit Size 00. Title Page - Update to new format. Unit size started from 00 changed to 003. Page 2- Change Table of Contents to Contents and repagenate. Pages 5-6 Model Numbers were combined from Code -23 for AV and AH units. Page 7- AV Codes continued from 24-36. Continued on the next page. Daikin Applied, 3600 Industrial Park Blvd., P.O. Box 55, Minneapolis, MN 55440 (763) 553-5330 UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 3

Parts List Revision History Revision Date Description N 09/3 Page 8- AH Codes continued from 24-36. (Cont.) Page 4- Add coils for AH unit size 008. Pages 9-9- Remove parts that are sheet metal and diagrams. Add AH unit Size 008. Page 20- Field Installed Accessories- Moved filters here. CPL- Added AH unit size 008. deleted AV units from this page CPL2- Added page for AV units. P 09/3 Numerous changes made. Size 008 added for all AH/UAHX units Title Page - Change model sizes for UAHX and UAVX units. Pages 5-7 Code was split into AH units and Av units. Pages 5-7 Code for AH/UAHX units. Page 8-0 Code for AV/UAVX units. Pages 9-9- Remove parts that are sheet metal and diagrams. Add AH unit Size 008. Pages 6-8 Add Pages for coil section. Page 24- Field Installed Accessories- Moved filters here. CPL- Added AH unit size 008. Deleted AV units from this page CPL2- Added page for AV units. Q 2/5 Rebrand Daikin format. Add unit size 07 to 00/003; 0 to 004; 3 to 005; 5 to 006; 20 to 008. Page 2- Delete unit size and detail A-A. Page 3- Delete unit size. Page 4- Add unit sizes 00, 03, 05. Change motor /4 HP p/n 06335370 to 063353702. Change coupling p/n GCA50005A to GC502C for /4HP motor. Change coupling p/n GCA50005A to GC86B for /3 & /2HP motors CPL, CPL2- Rebrand Daikin format. CPL2- Change motor /4 HP p/n 06335370 to 063353702. R 0/6 Page 2- Change 2-way valve 0565786 from " to 3/4". UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 4

Plant Identification AUB = Auburn U= Unit AUB U 08 05 00386 Serial Number (build sequence) Week of Manufacture Year of Manufacture 08= 2008 09= 2009 0= 200 etc. Model Number AH, UAHB, UAHF, UAHR, UAHV UAHB 003 C 0 F HWP 2 WY W Y C Y YY HC3 2M A C3 Code 0 02 03 04 05 06 07 08 09 0 2 3 4 5 6 7 2M7 B LY ST S W 2 BT A SFB YY T A Y Code 8 9 20 2 22 23 24 25 26 27 28 29 30 3 32 33 34 35 36 Code 0= Unit Type AH= Ceiling, Unit Ventilator UAHB= Ceiling, Face & Base, Reheat, Unit Ventilator UAHF= Ceiling, Face & Base, Unit Ventilator UAHR= Ceiling, w/valve Control, Reheat, Unit Ventilator UAHV= Ceiling, w/valve Control, Unit Ventilator Nomenclature Serial Number Code 07= MicroTech Occupied/Unoccupied Controls = Day-Night Changeover Relay, 24V 2= Day-Night Changeover Relay, 5V 3= Time Clock & Holiday Switch 5= None Y= Controls By Others Code 02= Unit Size 00= Series 000-500 CFM (AH only) 003= Series 3000-750 CFM (H07, S07) 004= Series 4000-000 CFM (H0, S0) 005= Series 5000-250 CFM (H3, S3) 006= Series 6000-500 CFM (H5, S5) 008= Series 8000-2000 CFM (H20, S20) Code 03= Vintage/Design C= Vintage C (example: AH003C) 3= Design C (example: UAHV3H07) Code 04= Unit Voltage 0= 230/60/ 27= 460/60/3 03= 208/60/ 29= 230/60/3 = 5/60/ 37=575/60/3 2= 208/60/3 47= 265/60/ Code 05= Damper F= Face & Bypass N= None Code 06= Temperature Controls Provider BRB= Siebe Pneumatic Factory Installed HWP= Honeywell Pneumatic Factory Installed JCP= Johnson Pneumatic Factory Installed LGP= Landis Gyr/Powers Pneumatic Factory Installed BCE= Barber-Colman Electric Factory Installed MN2= MicroTech Network-ASHRAE Cycle II MN3= MicroTech Network-ASHRAE Cycle III MP2= MicroTech Open Protocol-ASHRAE Cycle II MP3= MicroTech Open Protocol-ASHRAE Cycle III MA2= MicroTech Stand-Alone-ASHRAE Cycle II MA3= MicroTech Stand-Alone-ASHRAE Cycle III MM2= MicroTech Stand-Alone Master-ASHRAE Cycle II MM3= MicroTech Stand-Alone Master-ASHRAE Cycle III MS2= MicroTech Stand-Alone Slave-ASHRAE Cycle II MS3= MicroTech Stand-Alone Slave-ASHRAE Cycle III FLE= Controls By Others- Field Installed- Electric FLP= Controls By Others- Field Installed- Pneumatic Code 08= MicroTech Room Temperature Sensors UY= Unit Mounted WY= Wall Mounted w/o TC WT= Wall Mounted w/ TC CY= Wall Mounted w/ Comm Port w/o TC CT= Wall Mounted w/ Comm Port w/ TC YY= Controls By Others Code 09= MicroTech Tenant Override W= Wall Mounted (Part of Wall Sensor) N= None Y= Controls By Others Code 0= MT Room Temperature Setpoint Adj. ± 3 F W= Wall Mounted (Part of Wall Sensor) N= None Y= Controls By Others Code = MT Ventilation Relay A= Ventilation Lockout- 24V B= Ventilation Lockout- 5V C= Ventilation Interlock, Maximum- 24V D= Ventilation Interlock, Maximum- 5V N= None Y= Controls By Others Code 2= Shutdown Relay Code 3= Always YY Continued on the next page. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 5

Code 4= Heating Coil Type & Capacity Hot Water/Chilled Water- 2 Pipe HC3= 3-Row HC4= 4-Row HC5= 5-Row Hot Water HW= -Row HW2= 2-Row HW3= 3-Row Steam- Same End Drain SSL= Low Capacity SSH= High Capacity Electric Heat- Open Wire Element EW= Element 6EW= 6 Element 2EW= 2 Element 7EW= 7 Element 3EW= 3 Element 8EW= 8 Element 4EW= 4 Element 9EW= 9 Element 5EW= 5 Element Electric Heat- Sheathed Element ES= Element 6ES= 6 Element 2ES= 2 Element 7ES= 7 Element 3ES= 3 Element 8ES= 8 Element 4ES= 4 Element 9ES= 9 Element 5ES= 5 Element NNN= None Nomenclature Model Number- AH, UAHB, UAHF, UAHR, UAHV Code 5= MicroTech Heating Coil Valve Hot Water or Steam, 2-Way Modulating Valve 2M= ½"- #2 Port,.3CV 2M2= ½"- #3 Port, 2.2CV 2M4= ½"- #4 Port, 3.6CV 2M5= ¾"- #5 Port, 5.0CV 2M6= ¾"- #6 Port, 6.2CV Steam, 2-Way Modulating Valve 2M8= "- #7 Port, 8.2CV 2M9= "- #8 Port,.0CV Hot Water, 3-Way Modulating Valve 3M2= ½", 2.0CV 3M4= ½", 4.0CV 3M7= ¾", 6.8CV 2EC= 2-Way 2 Pos End of Cycle (" for ST; ¾" for HW) 3EC= 3-Way 2 Pos End of Cycle (¾") NNN= None YYY= Controls by Others Codes 8= Chilled Water Coil Valve 2-Way Modulating Valve 2M2= ½", 2.0CV 2M4= ½", 4.0CV 2M7= ¾", 6.8CV 3-Way Modulating Valve 3M2= ½", 2.0CV 3M4= ½", 4.0CV 3M7= ¾", 6.8CV 2EC= 2-Way 2 Pos End of Cycle (¾") 3EC= 3-Way 2 Pos End of Cycle (¾") NNN= None YYY= Controls by Others Code 9= Chilled Water Piping Package A= Incl. 2-Unions, S&R Pressure Taps, Shutoff Valve B= Incl. 2-Unions, S&R Pressure Taps, 2-Shutoff Valve C= Incl. 2-Unions, S&R Pressure Taps, Shutoff Valve & Flow Valve Code 20= Coil Connection Locations LY= Left Hand, Single Coil RY= Right Hand, Single Coil LR= Left Hand Cooling- Right Hand Heating RL= Right Hand Cooling- Left Hand Heating LL= Left Hand Cooling- Left Hand Heating RR= Right Hand Cooling- Right Hand Heating Code 2= Drain Pan = Standard 2= Stainless Steel Code 22= Exterior Panels ST= Standard Code 23= Access Panels S= Standard U= Unhinged Code 24= Paint Color of Unit Panels A= Putty Beige E= Soft Grey B= Soft Blue I= Antique Ivory C= Tile Black P= Prime Coat D= Goldenrod W= Off White Code 6= Hot Water Piping Package A=Incl. 2-Unions, S&R Pressure Taps, Shutoff Valve B= Incl. 2-Unions, S&R Pressure Taps, 2-Shutoff Valve C= Incl. 2-Unions, S&R Pressure Taps, Shutoff & Flow Valves Code 7= Cooling Coil Chilled Water C3= 3-Row C4= 4-Row C5= 5-Row Direct Expansion AC= Split System Air Conditioner HP= Split System Heat Pump NN= None Code 25= External Static Pressure = 0-.20" 2=.2-.45"(.2-.50" for Unit Size 008) Code 26= Fan Shaft & Motor Bearing = Oilable Sleeve 2= Permanently Lubricated Code 27= Air Inlet Location BT= Bottom Grille, RA, Top Duct Collar OA BR= Bottom Grille, RA, Rear Duct Collar OA BN= Bottom Grille RA, No OA RT= Rear Duct Collar RA, Top Duct Collar OA RR= Rear Duct Collar RA, Rear Duct Collar OA RN= Rear Duct Collar RA, No OA Continued on the next page. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 6

Code 28= Outdoor Air Damper A= Standard B= Standard w/setscrew Lock C= Cold Weather Insulated D= Cold Weather Insulated w/ Setscrew Lock R= None, Recirculation Unit Nomenclature Model Number- AH, UAHB, UAHF, UAHR, UAHV Code 29= Cabinet Mounting & Discharge Air Arrangement SFB= Standard, Front Discharge, Barsock Grille SFC= Standard, Front Discharge, Duct Collar SFV= Front Barsock Discharge Grille w/side Defl. Vanes PFD= Plenum, Front Discharge, Double Deflection Grille PBD= Plenum, Bottom Discharge, Double Deflection Grille PFC= Plenum, Front Discharge, Duct Collar PFB= Plenum, Front Discharge, Barsock Grille Code 32= Fiter Indicator = Dirty Filter Light Code 33= Return Air Staic Balance = Included Code 34= Auxiliary Drain Pan A= Included Code 35= Service Switch = Included Code 30= Always YY Code 36= Future Use Only- Always Y Codes 3= Filter Type P= Permanent Mesh M= Renewable Media w/metal Frame R= Roll Filter T= Throwaway UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 7

Nomenclature Model Number- AV, UAVB, UAVR, UAVS, UAVV UAVV 003 C 0 F HWP 2 WY W U C Y YY HC3 2M A C3 Code 0 02 03 04 05 06 07 08 09 0 2 3 4 5 6 7 2M7 B LY ST S A W D FR A FTD YY P A A A Y Code 8 9 20 2 22 23 24 25 26 27 28 29 30 3 32 33 34 35 36 Code 0= Unit Type AV= Floor, Unit Ventilator UAVB= Floor, Face & Base, Reheat, Unit Ventilator UAVR= Floor, w/valve Control, Reheat, Unit Ventilator UAVS= Floor, Face & Base, Unit Ventilator UAVV= Floor, w/valve Control, Unit Ventilator Code 02= Unit Size 00= Series 000-500 CFM (AV only) 003= Series 3000-750 CFM (H07, S07) 004= Series 4000-000 CFM (H0, S0) 005= Series 5000-250 CFM (H3, S3) 006= Series 6000-500 CFM (H5, S5) Code 03= Vintage/Design C= Vintage C (example: AV003C) 3= Design C (example: UAVV3H07) Code 04= Unit Voltage 0= 230/60/ 27= 460/60/3 03= 208/60/ 29= 230/60/3 = 5/60/ 37=575/60/3 2= 208/60/3 47= 265/60/ Code 05= Damper F= Face & Bypass N= None Code 06= Temperature Controls Provider BRB= Siebe Pneumatic Factory Installed HWP= Honeywell Pneumatic Factory Installed JCP= Johnson Pneumatic Factory Installed LGP= Landis Gyr/Powers Pneumatic Factory Installed BCE= Barber-Colman Electric Factory Installed MN2= MicroTech Network-ASHRAE Cycle II MN3= MicroTech Network-ASHRAE Cycle III MP2= MicroTech Open Protocol-ASHRAE Cycle II MP3= MicroTech Open Protocol-ASHRAE Cycle III MA2= MicroTech Stand-Alone-ASHRAE Cycle II MA3= MicroTech Stand-Alone-ASHRAE Cycle III MM2= MicroTech Stand-Alone Master-ASHRAE Cycle II MM3= MicroTech Stand-Alone Master-ASHRAE Cycle III MS2= MicroTech Stand-Alone Slave-ASHRAE Cycle II MS3= MicroTech Stand-Alone Slave-ASHRAE Cycle III FLE= Controls By Others- Field Installed- Electric FLP= Controls By Others- Field Installed- Pneumatic Code 07= MicroTech Occupied/Unoccupied Controls = Day-Night Changeover Relay, 24V 2= Day-Night Changeover Relay, 5V 3= Time Clock & Holiday Switch 5= None Y= Controls By Others Code 08= MicroTech Room Temperature Sensors UY= Unit Mounted WY= Wall Mounted w/o TC WT= Wall Mounted w/ TC CY= Wall Mounted w/ Comm Port w/o TC CT= Wall Mounted w/ Comm Port w/ TC YY= Controls By Others Code 09= MicroTech Tenant Override U= Unit Mounted W= Wall Mounted (Part of Wall Sensor) N= None Y= Controls By Others Code 0= MT Room Temperature Setpoint Adj. ± 3 F U= Unit Mounted W= Wall Mounted (Part of Wall Sensor) N= None Y= Controls By Others Code = MT Ventilation Relay A= Ventilation Lockout- 24V B= Ventilation Lockout- 5V C= Ventilation Interlock, Maximum- 24V D= Ventilation Interlock, Maximum- 5V N= None Y= Controls By Others Code 2= Shutdown Relay Code 3= Always YY Code 4= Heating Coil Type & Capacity Hot Water/Chilled Water- 2 Pipe HC3= 3-Row HC4= 4-Row HC5= 5-Row Hot Water HW= -Row HW2= 2-Row HW3= 3-Row Steam- Same End Drain SSL= Low Capacity SSH= High Capacity Steam- Opposite End Drain SDL= Low Capacity SDH= High Capacity Electric Heat- Open Wire Element EW= Element 6EW= 6 Element 2EW= 2 Element 7EW= 7 Element 3EW= 3 Element 8EW= 8 Element 4EW= 4 Element 9EW= 9 Element 5EW= 5 Element Electric Heat- Sheathed Element ES= Element 6ES= 6 Element 2ES= 2 Element 7ES= 7 Element 3ES= 3 Element 8ES= 8 Element 4ES= 4 Element 9ES= 9 Element 5ES= 5 Element NNN= None Continued on the next page. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 8

Nomenclature Model Number- AV, UAVB, UAVR, UAVS, UAVV Code 5= MicroTech Heating Coil Valve Hot Water or Steam, 2-Way Modulating Valve 2M= ½"- #2 Port,.3CV 2M2= ½"- #3 Port, 2.2CV 2M4= ½"- #4 Port, 3.6CV 2M5= ¾"- #5 Port, 5.0CV 2M6= ¾"- #6 Port, 6.2CV Steam, 2-Way Modulating Valve 2M8= "- #7 Port, 8.2CV 2M9= "- #8 Port,.0CV Hot Water, 3-Way Modulating Valve 3M2= ½", 2.0CV 3M4= ½", 4.0CV 3M7= ¾", 6.8CV 2EC= 2-Way 2 Pos End of Cycle (" for ST; ¾" for HW) 3EC= 3-Way 2 Pos End of Cycle (¾") NNN= None YYY= Controls by Others Code 6= Hot Water Piping Package A=Incl. 2-Unions, S&R Pressure Taps, Shutoff Valve B= Incl. 2-Unions, S&R Pressure Taps, 2-Shutoff Valve C= Incl. 2-Unions, S&R Pressure Taps, Shutoff & Flow Valves Code 7= Cooling Coil Chilled Water C3= 3-Row C4= 4-Row C5= 5-Row Direct Expansion AC= Split System Air Conditioner HP= Split System Heat Pump NN= None Codes 8= Chilled Water Coil Valve 2-Way Modulating Valve 2M2= ½", 2.0CV 2M4= ½", 4.0CV 2M7= ¾", 6.8CV 3-Way Modulating Valve 3M2= ½", 2.0CV 3M4= ½", 4.0CV 3M7= ¾", 6.8CV 2EC= 2-Way 2 Pos End of Cycle (¾") 3EC= 3-Way 2 Pos End of Cycle (¾") NNN= None YYY= Controls by Others Code 9= Chilled Water Piping Package A= Incl. 2-Unions, S&R Pressure Taps, Shutoff Valve B= Incl. 2-Unions, S&R Pressure Taps, 2-Shutoff Valve C= Incl. 2-Unions, S&R Pressure Taps, Shutoff & Flow Valves Code 20= Coil Connection Locations LY= Left Hand, Single Coil RY= Right Hand, Single Coil LR= Left Hand Cooling- Right Hand Heating RL= Right Hand Cooling- Left Hand Heating LL= Left Hand Cooling- Left Hand Heating RR= Right Hand Cooling- Right Hand Heating Code 22= Exterior Panels ST= Standard Code 23= Access Panels S= Standard K= Key Lock Code 24= Paint Color of Unit Panels A= Putty Beige E= Soft Grey B= Soft Blue I= Antique Ivory C= Tile Black P= Prime Coat D= Goldenrod W= Off White Code 25= Paint Color of Top A= Putty Beige H= Textured Charcoal Bronze B= Soft Blue I= Antique Ivory C= Tile Black P= Prime Coat D= Goldenrod W= Off White E= Soft Grey Code 26= Unit Depth/Adapter Back A= 6-5/8" Open Pipe Passage B= 6-5/8" Closed Pipe Tunnel C= 6-5/8" w/ 9" Vertical Finished Back D= 2-7/8" Adapter Back Pipe Passage E= 2-7/8" Full Adapter Back Closed Pipe Tunnel F= 2-7/8" Open Adapter Back K= 28" Total, Using -3/8" Top Extension L= 28" Total Closed Pipe Tunnel Full Adapter Back M= 2-7/8" Energy Recovery System Adapter Back Code 27= Air Inlet Location FR= Front RA, Rear OA FB= Front RA, Bottom Duct Collar OA FN= Front RA, No OA FT= Front RA, Top Duct Collar OA DR= Draft Stop RA, Rear OA DB= Draft Stop RA, Bottom Duct Collar OA DN= Draft Stop RA, No OA DT= Draft Stop RA, Top Duct Collar OA Code 28= Outdoor Air Damper A= Standard B= Standard w/setscrew Lock C= Cold Weather Insulated D= Cold Weather Insulated w/ Setscrew Lock R= None, Recirculation Unit Code 29= Cabinet Mounting & Discharge Air Arrangement Wall Mounted WFD= w/plenum Front Discharge, Double Deflection Grille WTB= Top Discharge, Barsock Grille Floor Mounted FTB= Top Discharge, Barsock Grille w/rh Top Access Door FDC= Top Duct Collar w/rh Top Access Door FTV= Top Grille, Side Deflection Vanes w/rh Top Access Door FTD= Top Barsock Grille w/rh & LH Top Access Doors FVD= Top Grille, Side Deflection Vanes w/lh Top Access Door FDD= Top Duct Collar w/rh & LH Top Access Doors Inverted Wall Mounted MFD= w/plenum Front Discharge, Double Deflection Grille MBB= Bottom Discharge, Bar Stock Grille Code 2= Drain Pan = Standard 2= Stainless Steel Code 30= Always YY UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 9

Codes 3= Filter Type P= Permanent Mesh M= Renewable Media w/metal Frame T= Throwaway Nomenclature Model Number- AV, UAVB, UAVR, UAVS, UAVV Code 32= Thru Piping in Upper Pipe Tunnel A= (2) 7/8" Uninsulated Straight Pipe B= () -5/8" Insulated Pipe- Supply C= () -5/8" Insulated Pipe- Return D= (2) -5/8" Insulated Pipe E= () 2-/8" Insulated Pipe- Supply F= () 2-/8" Insulated Pipe- Return G= (2) 2-/8" Insulated Pipe H= () -5/8" Supply & () 2-/8" Return Insulated J= () 2-/8" Supply & () -5/8" Return Insulated Code 33= Thru Piping in Lower Pipe Tunnel A= () -5/8" Insulated- Supply B= () -5/8" Insulated- Return C= (2) 2-/8" Uninsulated Code 34= Auxiliary Drain Pan A= Included Code 35= Service Switch = Included Code 36= Always Y UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 0

Unit Size 00-003/07 Adapter Back Kits 3 Fan Units Part Part Description Number 6.625 Closed Tunnel 06329003 6.625 Finished Back 06329039 2.875 Top Only 0565700 2.875 Full Open Tunnel 0632909 2.875 Full Closed Tunnel 06329249 2.875, 2 Step Down, Full Open 0778009 2.875, 2 Step Down, Full Closed 077929 28 Full Closed Tunnel 0763949 28" Top Only 060059 Unit Size 004/0 4 Fan Units Part Part Description Number 6.625 Closed Tunnel 06329004 6.625 Finished Back 06329049 2.875 Top Only 05657002 2.875 Full Open Tunnel 063299 2.875 Full Closed Tunnel 06329259 2.875, 2 Step Down, Full Open 077809 2.875, 2 Step Down, Full Closed 0779229 28 Full Closed Tunnel 0763959 28" Top Only 060069 Unit Size 005/3 5 Fan Units Part Part Description Number 6.625 Closed Tunnel 06329005 6.625 Finished Back 06329059 2.875 Top Only 05657003 2.875 Full Open Tunnel 0632929 2.875 Full Closed Tunnel 06329269 2.875, 2 Step Down, Full Open 0778029 2.875, 2 Step Down, Full Closed 0779239 28 Full Closed Tunnel 0763969 28" Top Only 060079 Unit Size 006/5 6 Fan Units Part Part Description Number 6.625 Closed Tunnel 06329006 6.625 Finished Back 06329069 2.875 Top Only 05657004 2.875 Full Open Tunnel 0632939 2.875 Full Closed Tunnel 06329279 2.875, 2 Step Down, Full Open 0778039 2.875, 2 Step Down, Full Closed 0779249 28 Full Closed Tunnel 0763979 28" Top Only 060089 UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page

External Cabinetry AV Cabinet 2 See Cabinet/Chassis components 2" "L" 24.80" 2" Ref Description Part Number Qty. No. Front Panel, End 2 2 Front Panel, Center N/S Cabinet/Chassis components Contact Daikin with unit model and serial number for part numbers on cabinet/chassis components. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 2

External Cabinetry AH Cabinet FRONT PANEL 2 Ref Description Part Number Qty. Bottom Rear Access Panel 2 Bottom Front Access Panel N/S Rear Panel Contact Daikin with unit model and serial number for part numbers on cabinet/chassis components. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 3

Fan Section Motor and Fan Unit Sizes 00-008 Components Ref. Description Part Unit Size/Qty. No. Number 00/003/07 004/0 005/3 006/5 008/20 N/S Shaft GC8504 N/S Shaft GC8505 N/S Shaft GC8506 N/S Shaft GC06 N/S Wheel, Plastic 06326290 2 3 4 5 N/S Wheel, Metal GF0 4 N/S Sleeve Bearing AV units 4ACE2556A N/S Ball Bearing AH units 4AAE7976 N/S Coupling, /4 HP Motor GC502C N/S Coupling /3 HP & /2 HP Motor GC86B N/S Housing AV units 0609920 2 3 4 5 N/S Housing AH units GCF532 4 N/S Gasket AV units 0562220 N/S Motor- AV Unit /4 HP, Sleeve Bearing until 4/02 0632670 /4 HP, Sleeve Bearing 4/02 & later 06326702 N/S Motor- AH Unit /4 HP, Ball Bearing 06335370 /3 HP, Ball Bearing 0765420 /2 HP, Ball Bearing LADQ5949 N/S = Not shown on diagram. Motors are 5/60/ regardless of unit voltage. It is important that the correct X transformer be installed (see Code 5 for voltage). NOTE: Do not mix plastic & aluminum wheels on same unit. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 4

Electric Heat Electric Heat Elements Description 00/003/07 004/0 005/3 006/5 008/20 3 Fan 4 Fan 5 Fan 6 Fan 4 Fan 500/750 CFM 000 CFM 250 CFM 500 CFM 2000 CFM ELECTRIC HEAT ELEMENT (HTR /9) Open Wire Element, 208V 0634360 06343602 06343603 06343604 06343604 Element, 230V 06343605 06343606 06343607 06343608 06343608 Element, 265V 0634370 06343702 06343703 06343704 06343704 Element, 460V 06343609 0634360 063436 0634362 0634362 Element, 575V 0634363 0634364 0634365 0634366 0634366 Sheathed Part Number/Unit Size Element, 208V 4EHH8887 4EHH8888 4EHH8889 4EHH8890 N/A Element, 230V 4EHH889 4EHH8892 4EHH8893 4EHH8894 N/A Element, 265V 0634450 06344502 06344503 06344504 N/A Element, 460V 4EHH8895 4EHH8896 4EHH8897 4EHH8898 N/A Element, 575V 4EHH8899 4EHH8900 4EHH890 4EHH8902 N/A Electric Controls Sch. Description Part Unit Size Sym. Number 00/003/07 004/0 005/3 006/5 008/20 F2A/F6C Fuse, 30A 208/230/265V 4EHG979 2-6 2-6 2-6 2-6 2-6 F2A/F6C Fuse, 60A 208/230/265V 4EHG4083 2-6 2-6 2-6 2-6 2-6 AF Airflow Switch 4EMB825 DF Deadfront Switch 4EAL2427 OH Thermostat, Overheat AV/AH 4ELN7697 OH2 Thermostat, Overheat AH 4ELN5523 UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 5

Coils Section Channel Mount Diagram Screw Part Number 4SBA4206 Coil Support Channel Part Number 5695870 Part Number Description 00 3 Fan 500 CFM 36" Long 003/07 3 Fan 750 CFM 36" Long 004/0 4 Fan 000 CFM 48" Long 005/3 5 Fan 250 CFM 60" Long 006/008/5/20 6 Fan 500/2000 CFM 72" Long Hot Water Hot Water, Low Capacity, -row N/A 076990 056953742 056953743 056953744 Hot Water, Med. Capacity, 2-row N/A 05695370 056953702 056953703 056953704 Chilled Water / Hot Water* Chilled Water, 3-row N/A 0569537 05695372 05695373 05695374 Chilled Water, 4-row N/A 05695372 056953723 056953725 056953727 Chilled Water, 5-row N/A 05695373 056953732 056953733 056953734 Steam** Steam,Low Capacity, -row N/A GRF03 GRF04 GRF05 GRF06 Steam, High Capacity, 2-row N/A GRF000 GRF00 GRF002 GRF003 Check Valve N/A 037520002 037520002 037520002 037520002 Direct Expansion Direct Expansion Coil 05705580 056666702 05666670 05666660 056666602 Direct Expansion Coil, Heat Pump N/A 056666702 05666670 05666660 056666602 Expansion Valve Expansion Valve 4FDV893 056662904 056662904 056662902 056662905 Check Valve (heat pump coil) N/A 037520002 037520002 037520002 037520002 N/A = Not Applicable * Reference Instructions - Hot Water Coil Mounting p/n 05705320. ** Reference Instructions - Cold Water Coil Mounting p/n 0570530. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 6

AV/AH Coil Section Coil Mount, Chilled Water Diagram (Ref. 570530) See Note 5 See Note 6 See Note 6 See Note 5 AIR FLOW AIR FLOW See Note 7 See Note 4 See Note 7 See Note 4 LEFT-HAND APPLICATION RIGHT-HAND APPLICATION 20 2 30 DETAIL "A" 2 9 Plug from Coil Ref. Note NOTES:. Remove upper plug Item 30 from coil and install in Item 2 as shown in Detail "A". 2. Return label is placed always opposite drain connections. Supply label is placed always at center connection. 3. Braze Item with drain at bottom of connection. 4. Drain connection floor unit or wall unit. 5. Drain connection ceiling. 6. Chilled water coil located on leaving air side (position 2) when used with hot water, steam or electric heat. 7. Chilled water coil located on entering air side (position ) when single coil. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 7

AV/AH Coil Section Coil Mount, Hot Water Diagram (Ref. 5705320) See Note 6 See Note 5 See Note 5 See Note 6 AIR FLOW See Note 4 See Note 7 See Note 7 See Note 4 LEFT-HAND APPLICATION RIGHT-HAND APPLICATION 20 2 30 DETAIL "A" 2 9 Plug from Coil Ref. Note NOTES:. Remove upper plug Item 30 from coil and install in Item 2 as shown in Detail "A". 2. Return label is placed always opposite drain connections. Supply label is placed always at center connection. 3. Braze Item with drain at bottom of connection. 4. Drain connection floor unit or wall unit. 5. Drain connection ceiling. 6. Hot water coil located on leaving air side (position 2) when used with direct expansion coil. 7. Hot water coil located on entering air side (position ) when single coil or with chilled water coil. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 8

Ref. Description Part Unit Size No. Number 00/003/07 004/0 005/3 006/5 008/20 N/S Drain Pan AV GCF504 N/S Drain Pan AV GCF505 N/S Drain Pan AV GCF506 N/S Drain Pan AV GCF507 N/S Drain Pan, -Coil AH GCF5225 N/S Drain Pan, -Coil AH GCF5226 N/S Drain Pan, -Coil AH GCF5227 N/S Drain Pan, -Coil AH GCF5228 N/S Drain Pan, 2-Coil AH GCF509 N/S Drain Pan, 2-Coil AH GCF5020 N/S Drain Pan, 2-Coil AH GCF502 N/S Drain Pan Kit, 2-Coil AH 0567250 N/S Auxillary Drain Pan (C29 = FTB only) 0567770 N/S Auxillary Drain Pan (C29 = SFB only) 0567780 N/S Drain Plug 4RHD896 N/S Shaft, Damper GC0747 N/S Counterweight GC0744 2 N/S Counterweight GC0745 2 2 N/S Crankarm GCF5203 2 2 2 2 N/S = Not shown on diagram. Damper Section Drain Pan, and Face & Bypass Damper Components UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 9

Damper Section OA & Room Air Damper Components Ref. Description Part Unit Size No. Number 00/003/07 004/0 005/3 006/5 008/20 N/S Damper, OA 500/750 CFM 060030 N/S Damper, OA 000 CFM 060040 N/S Damper, OA 250 CFM 060050 N/S Damper, OA 500 CFM 060060 N/S Damper, Room Air 500/750 CFM 0609580 N/S Damper, Room Air 000 CFM 0609590 N/S Damper, Room Air 250 CFM 0609600 N/S Damper, Room Air 500 CFM 060960 N/S Bearing, Sleeve 4ACN49 5 5 5 5 5 N/S Spring, Damper 05708660 N/S Crankarm GCF5474 N/S Crank GCF5000 N/S OA Shaft Assy 0645280 N/S Shaft until 2/99 GC634 N/S Shaft 2/99 & later 056280 N/S Shaft until 2/99 GC0024 N/S Shaft 2/99 to 3/04 056260 N/S Right Side Actuator Assy 2/99 & later 05622002 N/S Gasket BJ027000 5 Ft. 6 Ft. 7 Ft. 8 Ft. 8 Ft. N/S Mohair BY00000 3 Ft. 7 Ft. 2 Ft. 25 Ft. 25 Ft. N/S = Not shown on diagram. Replaces counterweight - RA (GC2A), angle, and screw. 2 In February 999, a second "slave" actuator was added to the right side of the room air damper. The new shafts are only used when this additional actuator is present. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 20

Hydronic Valves and Actuators Ref. Description Part Unit Size No. Number 00/003/07 004/0 005/3 006/5 008/20 N/S 3-Way Valve /2" Connections, #2 Port, 2.2 CV 0560020 /2" Connections, #4 Port, 4.4 CV 05600202 3/4" Connections, #6 Port, 7.5 CV 05600203 N/S 2-Way Valve /2" Connections, #2 Port,.3 CV 0560030 /2" Connections, #3 Port, 2.2 CV 05600302 /2" Connections, #4 Port, 4.4 CV 05600303 3/4" Connections, #5 Port, 5.5 CV 05600304 3/4" Connections, #6 Port, 7.5 CV 05600305 " Connections, #7 Port, 0.0 CV 05600306 " Connections, #8 Port, 4.0 CV 05600307 N/S End Of Cycle Valve Kits- 2 Way Valves 3/4" Connections, Straight, 8.0 CV 0565786 3/4" Conn., Normally Closed, 7.0 CV 0565787 " Conn., Normally Open, 7.0 CV 0565784 N/S End Of Cycle Valve Kits- 3 Way Valves 3/4" Conn, NO/NC, 7.0 CV 0565785 N/S Actuator Actuator, OA 0560040 Actuator, FBP 0560040 Actuator, Water & Steam 0566070 N/S = Not shown on diagram. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 2

Controls Ref. Sch. Description Part Unit Size No. Sym. Number 00 003 004 005 006 008 07 0 3 5 20 N/S --- PC Board Control MicroTech M325 0762720 N/S Sensor- Humidity Transducer 0604860 N/S S Sensor- Room Temp Unit Mtd. GEF947 N/S S Sensor- Room Temp Wall Mtd. N/S S2 Sensor, Discharge Air Temp GEF947 N/S S3 Sensor, Outdoor Air 80" GEF948 N/S S4 Sensor, Mixed Air Temp 3 Fan 063297203 Sensor, Mixed Air Temp 4 Fan 063297204 Sensor, Mixed Air Temp 5 Fan 063297205 Sensor, Mixed Air Temp 6 Fan 063297206 N/S S5 Sensor, Water Temp GEF948 N/S T4 Thermostat, Low Temp DE Coil 4ELN7604 N/S T6 TStat, Low Temp 44" Cap Tube 4ELN978 N/S X Transformer- Motor Speed /4 HP Motor 20V Primary 0565800 /4 HP Motor 208/265V Primary 063338302 /3 or /2 HP Motor 5/460/575V 4EPB8039 /3 or /2 HP Motor 208/230/265-277V 4EPB8040 N/S X2 Transformer- DE Cool 40 VA 5/460/575V 060630802 40 VA 208/230V/24V 060630802 40 VA 277/24V 060630802 N/S X3 Transformer- Control 75 VA 20V-24V Sec 062986902 75 VA 208/240-24V 0567770 75 VA 265-277/460-24V 4EPC977 N/S X4 Transformer- Step Down 500 VA 460/240V 4EPC6552A 750 VA 460V 4EPC7743 N/S X5 Transformer 40VA 208/240-24V 06304240 50VA 277-24V 060630702 40VA 20-24V 060630802 N/S X6 Transformer, UVC 4EPC988 N/S --- PC Board Controls Controls By Others T4 Thermostat, Control- DE DE Enter @28 F 4ELN7604 REC Receptacle, 5Amp, Dual Voltage until 4/04 4EGA4209 RC3 Receptacle, DE- 20Amp until 4/04 4EGA4307 Plug, Shorting until 4/04 4EFA9248 Plug 4EFA873 TDR2 Time Delay Relay Anti-Short, 5 min. 4EWS7798 Cord-Set 0Amp, 5V, 07" 0678350 N/S = Not shown on diagram. Contact local Parts Distributor. Unit model and serial number is required for proper identification. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 22

Controls Fuses, Relays, Switches and Time Clock Bub. No. Ref. No. Description Part Number N/S X7 Fuseholder 4EHB933 N/S FC/FD Fuse, X4 Transformer, 4.0 amp 4EHG7663 N/S FC/FD Fuse, X4 Transformer, 3.5 amp 4EHG773 N/S FA Fuse, 0.0 amp 4EHG7795 N/S FA Fuse, 9.0 amp 4EHG8684 N/S FA Fuse, 7.0 amp 4EHG7750 N/S FA Fuse, 6.25 amp 4EHG890 N/S FA Fuse, 5.6 amp 4EHG7749 N/S FA Fuse, 5.0 amp 4EHG8089 N/S FA Fuse, 4.5 amp 4EHG7664 N/S FA Fuse, 4.0 amp 4EHG7663 N/S FA Fuse, 3.5 amp 4EHG773 N/S FA Fuse, 3.0 amp 4EHG7748 N/S --- Cord Set, Motor Plug, 24" 4EFZ7630 N/S --- Cord Set, Motor Receptacle, 6" 4EGZ7629 N/S --- Receptacle, Dual Volt 4EGA4209 N/S --- Receptacle, DE Cool 4EGA4307 N/S R4 Fan Relay until 6/99 4EWJ8505 Fan Relay * 6/99 & later 4EWJ9054 N/S R5 Night Setback Relay 24V 4EWJ9054 Night Setback Relay 5V 4EWJ9053 N/S R6 Vent Lockout Relay 24V 4EWJ9054 Vent Lockout Relay 5V 4EWJ9053 N/S R8 RVSG Valve Relay, DE Cooling 4EWJ8799 N/S C/C Elec. Ht. Relay Operating & Backup 4EWJ8799 N/S R3 Interlock Exhaust Fan Relay 24V 4EWJ9054 Interlock Exhaust Fan Relay 5V 4EWJ9053 N/S TDR Time Delay Relay, Low Volt. Prot. Electric Heat 4EWS7798 N/S SW Switch, Disconnect, Electric Heat, 00 amp 4EUL6509A Switch, Disconnect, Electric Heat, 225 amp 4EVQ639 N/S SW Switch, Disconnect, Non-Electric Heat 06660 N/S SW2 Switch, Fan Speed, Remote GE420A N/S SW2 Rotary Switch, 2-Pole (20V, 227V) 05754300 N/S SW2 Rotary Switch, 3-Pole (208V, 230V) 05754290 N/S --- Knob (Rotary Switch) 8020803 N/S SW3 Switch, Day-Night/TOR 4EAL726 N/S SW4 Switch, Holiday 4EAL7260 N/S SW5 Switch, Emergency, Elec. Heat, Heat Pump 4EAL726 N/S SW6 Switch, Energy Conserving, Heat Pump 4EAL7759 N/S TC 24 hour Time Clock with Reserve Power, 20V 4ETA9083 N/S TC 24 hour Time Clock with Reserve Power, 208-230V 4ETA9094 N/S Ref. Time Clock Instruction with Reserve Power GE424 N/S = Not shown on diagram. * If 4EWJ9054 is installed on units built prior to June 5, 999, the R4 harness terminals must be field retrofitted with /4" terminals. Dual voltage receptacle was removed from std control box, per PC 9754, effective 0-6-89. (Used in "Controls By Others" application.) UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 23

Field Installed Accessories Filters Ref. Description Part Unit Size No. Number 00/003/07 004/0 005/3 006/05 008/20 N/S Filter, Air- Permanent Aluminum GO006 Box of 25 GO006 0563740 N/S Filter, Air- Permanent Aluminum GO007 Box of 25 GO007 0563750 N/S Filter, Air- Permanent Aluminum GO008 Box of 25 GO008 0563760 N/S Filter, Air- Permanent Aluminum GO006 2 2 Box of 25 GO006 0563740 N/S Filter, Air- Throwaway GO279C Box of 2 GO279C 0563780 N/S Filter, Air- Throwaway GO280C Box of 2 GO280C 0563790 N/S Filter, Air- Throwaway GO28C Box of 2 GO28C 0563800 N/S Filter, Air- Throwaway GO279C 2 2 Box of 2 GO279C 0563780 N/S Renewable Filter Rack & Media GOF50 Box of 25 GOF50 0563700 N/S Renewable Filter Rack & Media GOF502 Box of 25 GOF502 056370 N/S Renewable Filter Rack & Media GOF503 Box of 25 GOF503 0563720 N/S Renewable Filter Rack & Media GOF50 2 2 Box of 25 GOF50 0563700 N/S Renewable Media KJ000400 N/S = Not shown on diagram. UV; AH00-008C, UAHX07-20 Des. 3, AV00-006C, UAVX07-5 Des. 3 Rev. R 0/6 RPL 05758 / Page 24

Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! AAF Unit Ventilators Herman Nelson Unit Ventilators AH 00-008, Vintage C UAHB, UAHF, UAHR, UAHV 07-20 Design 3 Critical Components Unit Sizes Voltage Part Number Control MicroTech M325 Controller ALL ALL 0762720 Blower Fan Motor Motor, Ball Bearing, /4HP 00-008 (07-20) 5/60/ 06335370 Motor, Ball Bearing, /3 HP 00-008 (07-20) 5/60/ 0765420 Motor, Ball Bearing, /2 HP 00-008 (07-20) 5/60/ LADQ5949 Blower Fan Assembly Fan Housing 00-006 (07-5) N/A 0609920 Fan Housing 008 (20) N/A GCF532 Fan Wheel, Metal 00-006 (07-5) N/A 06325760 Fan Wheel, Plastic 00-006 (07-5) N/A 06326290 Fan Wheel, Plastic 008 (20) N/A GF0 Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To www.daikinapplied.com or Call -800-37PARTS 5758 Rev. R 0/206 CPL Page of 2

Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! AAF Unit Ventilators Herman Nelson Unit Ventilators AV 00-006, Vintage C UAVB, UAVR, UAVS, UAVV 07-5 Design 3 Critical Components Unit Sizes Voltage Part Number Control MicroTech M325 Controller ALL ALL 0762720 Blower Fan Motor Motor, Sleeve Bearing, /4HP 00-006 (07-5) 5/60/ 06326702 Blower Fan Assembly Fan Housing ALL N/A 0609920 Fan Wheel ALL N/A 06326290 Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To www.daikinapplied.com or Call -800-37PARTS 5758 Rev. R 0/206 CPL Page 2 of 2