Conventional Smoke Detectors KFAPO

Similar documents
Multiple Input and Output Modules

Series 65 Product Guide MAN 3036

SERIES 65 ENGINEERING PRODUCT GUIDE

F220-B6PS/M. Installation Guide. Addressable Detector Bases

Speakers and Speaker Strobes

D250A/D253/D261AW/D280A/D290 Series

SP40S-D. Kingfisher Company, inc. Features: Description:

ALK-V PHOTOELECTRIC SMOKE SENSOR

SECTION FIRE ALARM SYSTEMS

Installation Instructions Model HZM

Figure 1. Figure 2. See notes 1 and 2 below.

SERIES 65 ENGINEERING PRODUCT GUIDE

MANUAL RESET ALARM RELEASE BOX

MANUAL RESET ALARM RELEASE

Conventional Fire Alarm System 2014 V1.2

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

WARNING. Installation Tip: Try out this unit before installing onto a fire door system. Test and learn the release INTRODUCTION

LF /2. Fire Alarm Control Panel. Features:

Addressable Detectors & Bases

1 Watt Supervised Self-Amplified Strobe Speakers Round Flush Grille with 75cd Strobe

Emergi-Lite Orbis detectors

EFBW series - BiWire Ultra control panel

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

Reflective Optical Beam Smoke Detector User Guide

TECHNICAL DATA OBSOLETE

INSTRUCTION & SERVICE MANUAL

TrueAlarm Smoke Detectors

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

MANUAL RESET ALARM RELEASE

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

Firefly II Multi Voltage RELEASE DEVICES. Firefly II & IIB-MV INSTALLATION MANUAL

Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Addressable NAC Output Module D327A

Installation, Operating and Maintenance Manual

LF-4000 Series Conventional Fire Alarm Control Unit

ESL 500N Series Smoke Detector Installation Sheet

FCPS-24F FIRE ALARM FIELD CHARGER/POWER SUPPLY FOR FIRE PROTECTION/SIGNALING SERVICE FCPS-24F/FCPS-24FE. Field Charger/Power Supply

OPERATION AND INSTALLATION MANUAL

Installation Instructions Model ABHW-4S

PRODUCT OVERVIEW SM-501 AT-A-GLANCE

Air Specialties Express, 448 S. Main St., P. O. Box , Verona, WI Phone: (877) Fax: (608)

Installation Manual. Detector Bases: PAD100-IB, PAD100-RB & PAD100-SB

Notification Appliance Circuit Module

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

D7052. Installation Instructions Multiplex Dual Input Module

D7050DH. Installation Instructions. Multiplex Photoelectric Duct Smoke Detector

2000 Series Sensors Installation Guide

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Table 1: Attenuation Rating Switch Position. Position Attenuation (db) Attenuation (db) (Approx.)

1. POWERPATH Operation

Intelligent Security & Fire Ltd

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

D7044. Installation Instructions Multiplex Single Input Module

D7053. Installation Instructions Multiplex Input/Output Module

1400 Direct Wire Ionization Smoke Detector

Engineering Product Guide Ionisation Smoke Detectors Optical Smoke Detectors Resettable Heat Detectors

16.34 Multiplex Fire Alarm System Construction Standards Page 1 of 5

OH110, OP110, HI110 Automatic fire detectors

8600 EMR SERIES. INSPK NO Rev.06/ INS NO. GENERAL DESCRIPTION

You in Control PRODUCT OVERVIEW

PAD100-6DB & PAD100-4DB PAD100-PD

MR-2602 Two Zone Fire Alarm Control Panel

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Industries. As a premier global manufacturing company, we believe that great brands are

RELEASE DEVICE CONTROLS

Installation Manual CFP-105. Fire Alarm Control Panel. Version 1.0

MS-4012/4024 and CMS-4012/4024. Instruction Manual for the. Fire Alarm Control Panels

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

Analogue addressable devices

SOLID STATE SECURITIES, INC. THE "SS90" SERIES RELEASE DEVICES MADE IN THE U.S.A. SS90-WPS MODEL A/B INSTALLATION MANUAL

* These Remote Mics must be SPRM-GP

TECHNICAL DATA. Humidity: 85% Relative Humidity (non-condensing) at 90 F (32 C) maximum.

Conventional Releasing Control Panel

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

UEI-1 UNIVERSAL END-OF-LINE / ISOLATOR TESTER

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

TrueAlarm Analog Sensing

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

General Routing Interface

DS7400Xi Addressable Control/ Communicator

LifeAlarm Fire Alarm Controls

TrueAlarm ES Analog Sensing

INSTRUCTION MANUAL (ATEX / IECEx)

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

D285DH. Installation Instructions Photoelectric Duct Smoke Detector

PSN-1000 & PSN 1000(E) Installation Manual

Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODELS: ST-H15-B & ST-H30

INSTRUCTION MANUAL. AlarmGard Chain Operator (Model FCA) AlarmGard Crank Operator (Model FKA)

MODEL B2 INSTALLATION MANUAL

Addressable Fire Alarm Control Panel

ORBIS PRODUCT GUIDE. Optical Detector. Multisensor Detector. Heat Detector. Mounting Bases

PRODUCT OVERVIEW. SL-2000 AT-A-GLANCE MODEL NUMBER: SL-2000-N 4-Wire Ionization Duct Smoke Detector SL-2000-P 4-Wire Photoelectric Duct Smoke Detector

Fire Product Catalog

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

Transcription:

Kingfisher Company, inc. Conventional Smoke Detectors KFAPO Features: Wide operating voltage, 9-33 VDC Advanced electronic technology Flashing LED Magnetic test switch Proven detection performance Designed to meet approvals worldwide Range of bases available Description: KFAPO Series Smoke Detectors incorporate well-proven sensing technologies, together with advances in materials and electronics technology. The KFAPO Series Smoke Detectors were developed for the safe detection of a wide range of smoke aerosols. The dual chamber principle with measurement and reference chamber ensures the automatic compensation of environmental impact. KFAPO-PE Photo Electric Smoke Detector: Optical smoke detectors incorporate a pulsing LED located in a chamber within the housing of the detector. The chamber is designed to exclude light from any external source. At an angle to the LED is a photo-diode which normally does not register the column of light emitted by the LED. In the event of smoke from a fire entering the chamber, the light pulse from the LED will be scattered and hence registered by the photo-diode. If the photo-diode sees smoke on the two following pulses, the detector changes into the alarm state and the indicator LED lights up. The detector housing is identical to that of the ionization detector but has an indicator LED which is clear in quiescent state but produces red light in alarm.

Standard Detector Bases: The bases are 4 in diameter and have five terminals marked according to their function: Line 1 in, line 1 out, line 2 in and out, remote indicator negative, earth. Detectors are polarity insensitive, so that identification of positive and negative lines is only required if a remote LED is fitted. An earth connection is not required for either safety or correct operation of detectors. The earth terminal is provided for tidy termination of earthed conductors or cable screens and to maintain earth continuity where necessary. Bases have a wide interior diameter for ease of access to cables and terminals and there are two slots for fixing screws at a spacing of 2 to 2.75. Detectors fit into bases one way only and require clockwise rotation without push force to be plugged in. They can be locked into the base by a grub screw using a 1.5mm hexagonal driver. Relay Bases Application Series APO relay bases are primarily intended for use with control units using 4-wire detector supply and alarm initiating circuits. Where local codes allow, they may also be used in 2- and 4-wire circuits to provide volt-free control signals to an auxiliary system such as an automatic door closer. They are not suitable for use in systems where it is specified or required that operation of the auxiliary system shall be fail-safe and must not be used with any other type of detector. The Standard relay base, provides one set of volt-free, changeover (form C) contacts that change state when the detector signals an alarm. Kingfisher Company, inc. 81 Old Ferry Road - Lowell, MA 01854 2

The Auxiliary relay base, provides two sets of volt-free changeover contacts to facilitate the switching of a remote LED or other auxiliary device. The EOL (end-of-line) relay bases are intended for use with 4-wire circuits and feature two sets of changeover contacts and a power supervision relay. The Series APO Sounder Base is a high-efficiency conventional alarm sounder. The product offers 32 tones. The sounder base can be secured to a conduit box, a sounder ceiling plate or surface mounted. Sounder Bases should be located to ensure correct operation of the detector in accordance with the detector manufacturer s recommendations and local regulations or codes of practice. Note: The sounder is suitable for indoor use only. The sounder base is designed so that separate detector and sounder circuits can be connected. The sounder circuit is connected using the PCB mounted 4-way terminal block. The detector circuit is connected using the terminals marked L1IN, L1OUT and L2 around the rim of the base in the same way as a standard detector base. Two separate earth terminals are provided to allow the screen termination of earth conductors to maintain continuity between cables that contain an earth conductor. As this product is designed for use on conventional systems with separate detector and sounder circuits, the earths should not be connected together. Specifications: KFAPO Photo Smoke Detectors Supply voltage Average quiescent current at 24V Average quiescent current at 9V Alarm current at 24V Alarm current at 9V Alarm indication Normal operating temperature - Max wind continuous Remote output (R-) characteristics Flashing LED and Magnetic Test Switch 9 to 33V 45μA 21μA 52mA 17mA Red LED 20 to +60 C (no condensation or icing) 10m/s Current sink to -ve line, limited to 17mA. Note: when using a remote indicator a current-limiting series resistor may be required. Kingfisher Company, inc. 81 Old Ferry Road - Lowell, MA 01854 3

Specifications continued: Series APO Relay Bases Relay base type Standard Auxiliary EOL Supply voltage 9 to 33V 9 to 33V 16 to 33V Normal operating temperature -20 to +70 C -20 to +70 C 20 to +70 C (no condensation or icing) Relay ratings: Maximum switching power 30W, 50VA 30W, 50VA 30W, 50VA Maximum switching current 1A (resistive load) 1A (resistive load) 1A (resistive load) Maximum switching voltage 50V AC 50V AC 50V AC \Minimum capability 10μA, 10mV DC 10μA, 10mV DC 10μA, 10mV DC Dropout voltage <6V <6V <6V Series APO Sounder Base Operating voltage: 17 to 30VDC Alarm Currents: External Supply: 17mA @ 24VDC Associated Detector: 8mA @ 24VDC Standby Currents: 0.15µa @ 24VDC Audible Intensity: High Volume Selection: 85dB @ 10 feet Low Volume Selection: 75dB @ 10 feet Wiring Solid or Stranded: #12 to #22 AWG Terminals Environmental: 32 F to 100 F (0 C to 38 C) 0% to 85% RH; Non-Condensing / Non-Freezing Material: Makrolon 6455 or 6555; 94V-0 Dimensions: 6 L x 6 W x 1.6 D (152mm x 152mm x 41mm) Kingfisher Company, inc. 81 Old Ferry Road - Lowell, MA 01854 4

ORDERING INFORMATION KFCI # Model # Description 84112 KF225-APO Smoke Detector Head (Ionization) 84113 KF325-APO Smoke Detector Head (Photoelectric) 84114 KF251-APO Detector Base 2 Wire, 6 1/4 84115 KF456-APO Detector Base (4-Wire w/ Relay) 84186 KFMB-SDRT-CV Detector Base (4-Wire w/ Sounder Base) 84121 KF258-APO Detector Base ( 4 w/ EOL) 81089 KFMSRA Remote LED, (Single Gang) 84112-DTS Specification Data Sheet King-Fisher Company, inc., products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained and operationally tested in accordance with their installation instructions at the time of installation and at least twice a year or more often and in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance and testing must be performed by qualified personnel for proper operation in accordance with all of the latest National Fire Protection Association (NFPA), Underwriters Laboratories (UL), National Electrical Code (NEC), Occupational Safety and Health Administration (OSHA), local, state, county, province, district, federal and other applicable building and fire standards, guidelines, regulations, laws and codes including, but not limited to, all appendices and amendments and the requirements of the local authority having jurisdiction (AHJ). NOTE: Due to continuous development of our products, specifications and offerings are subject to change without notice in accordance with King-Fisher Company, inc., standard terms and conditions King-Fisher Company, inc. 81 Old Ferry Road - Lowell, MA 01854 5

BLANK PAGE LEFT INTENTIONALY King-Fisher Company, inc. 81 Old Ferry Road - Lowell, MA 01854 6