PROGRAMMABLE 7-DAY RF THERMOSTAT

Similar documents
PROGRAMMABLE 7-DAY THERMOSTAT

BeSMART Thermostat. EN Thermostat Manual

Vokèra OpenTherm 711 with external sensor connected

Vokèra OpenTherm 711 without external sensor connected

Easy-Stat. Wireless Programmable Room Thermostat Pt No

C-Stat 17-ZW User Instructions

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

Installer and User Manual. BeSMART. Thermostat WiFi Box and boiler RF receiver. Installer and User Manual ESC MODE SET PROG RESET

Digital Electronic Thermostat With RF

Digital Electronic Thermostat With RF

Model: RT310RF. Installation Manual

RF Programmable Room Thermostat Installation Instructions

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

1 DOCUMENT REVISION CONTROL ELEMENTS... 9

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

irad Wireless Controller

CentaurPlus ZW and HRT4-ZW

CS027 User Instructions

Wall Hung Boiler Room Thermostat OR30 OT Thermostat

ThermoPlus AS2-RF & ASR-RF Installation Instructions

CET B-RF Wireless Electronic Hot Water Cylinder Thermostat User & Installation Instructions

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

Electronic Thermostat With RF

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

User Manual THR842DUK Wireless Digital Thermostat

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Model: RT310i. Smartphone Controlled Thermostat. Installation Manual

RF Programmable Room Thermostat User Instructions

Operating and Installation Manual VRC 430f. Weather compensator controller with radio transmission. For the operator / for the heating engineer

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

Drayton Digistat +3RF

Programmable Room Thermostat Installation Instructions

KIT UNITÀ AMBIENTE E INTERFACCIA A LED KIT ROOM UNIT AND LED INTERFACE RAUMGERÄT UND LED-SCHNITTSTELLE KIT APPAREIL D'AMBIANCE ET INTERFACE À LEDS

Installation & User s Instructions

SRT321 User and Installation Instructions

User Manual THR872CUK Wireless Programmable Thermostat

Digital Room Thermostat

INSTRUCTION MANUAL REMOTE CONTROL DEVICE EASYREMOTE

Model: RT510RF. Installation Manual

User Manual THR870CUK Programmable Thermostat

Modulating clock thermostat

Model: Available in: Sapphire Black and Glacier White. 1 Series

Honeywell Homes T3, T3M & T3R

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz

Operating Instructions Model: PRT-TS WiFi RF. 01/13 Version 1 Ref: PRT-TSWIFI RF

Model: Touch-RF. 1 Wireless Series

Model: Touch-RS. 1 Touch-RS

Programmable Towel Radiator Manual

Programmable Thermostat with Plug in RF Boiler Control Model: ST620VBC INSTRUCTION MANUAL

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

Installation and Instructions for Use Outdoor Sensor

RF ELECTRONIC PROGRAMMABLE ROOM THERMOSTAT, 7 DAY

AUTO CM CM USER GUIDE

Model: Available in : Sapphire Black and Glacier White. 1 Series

Installation instructions. For the heating engineer. Installation instructions. timeswitch VTS 160 GB, IE

Grant Aerona³. Air to Water High Efficiency Heat Pump Range. User Instructions

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

EUROSTER 2510TX USER MANUAL EUROSTER 2510TX

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

INSTALLATION INSTRUCTIONS

CM907- TRV PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

CET2000B-RF + RX1-S + CS2

ESRTP4RF. RF Programmable Room Thermostat with TPI, Optimum Stop, Delayed & Optimum Start. User and Installation Instructions

MAKING MODERN LIVING POSSIBLE. TP7001 Range Electronic 7 Day Programmable Room Thermostat. User Guide. Danfoss Heating

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

EasyTronic III MANUAL SERVICE

LYRIC T4, T4R& T4M PRODUCT SPECIFICATION SHEET FEATURES

ET4 heat/cool day RF programmable room thermostat. ET4 Receiver

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

Quick start guide. Connected wireless room thermostat. Logic Combi C / Logic Max Combi C / Vogue Gen 2 Combi / Vogue Max Combi

Model: Slimline-RF. 1 Slimline Series

Room thermostat with Auto Timer, independent DHW

Installation, Start-Up, and Operating Instructions

Installation guide. Wireless room thermostat with hot water control (DHW & single zone CH)

Climapro 2. Installation. wireless room thermostat without receiver.

RADIO DRIVER. * _Rev.1* User guide. Wireless programmer. RADIO DRIVER zone RADIO DRIVER zones RADIO DRIVER zones

ENGLISH. REMOTE CONTROL / ROOM THERMOSTAT Wireless INSTALLATION SERVICING AND USER MANUAL

Floor heating controls, radio connection 1

Watts Under Floor Multi-zone Controller User Manual

TPOne-B. Electronic Programmable Room Thermostat. Installation Guide. Danfoss Heating

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override

THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE.

The Vitro-i. Radiant / Convector Combination Heater. Instructions for Operation and Installation

CM707. Programmable Room Thermostat with Optimum Start, Optimum Stop and Delayed Start. User Guide

O CRC100. Comfort Room Controller (2015/01) en

evohome Sundial pack Thermostat

ARLEC. User Instructions

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi

Water Tank Level Monitor

ST9400S User Guide. 1 Day Programmer, 2 channel With Boiler Service Reminder / Shut-down Feature

EUROSTER 2510 USER MANUAL 1 EUROSTER 2510

SCS311 / SCS317 Installation Instructions

Climapro 2. User manual. wireless room thermostat without receiver. To be left with the user.

Honeywell. Wireless Rain Gauge with Indoor. Temperature (TC152) USER MANUAL TABLE OF CONTENTS INTRODUCTION 3 PRODUCT OVERVIEW 4 REMOTE RAIN GAUGE 7

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

Transcription:

PROGRAMMABLE 7-DAY RF THERMOSTAT Installation and user instruction This instructions to be retained by the user 1

Thank you for choosing Beretta s radio frequency (RF) Radiostat. This central heating control device is easy to fit, and with correct use, will deliver improved comfort levels in your home whilst saving you money. This thermostat is designed to be used only with heating controls system with a maximum switching load of 2A at 30VDC or 0,25A at 230VAC or with Beretta boilers fitting a bus protocol connection If installing for someone else, please ensure that the instructions are handed to the householder. Warning: Please read this manual prior to installation or use. Shock Hazard: This unit must be installed by a competent person, in accordance with local regulation, or other relevant national regulations and codes of good practice. Always isolate the AC Mains supply before installing this unit. CE: This product is according R&TTE Directive 1999/5/EC Installation warning: This programmer can be used either as a central heating ON/OFF thermostat and as boiler remote control (only with selected Beretta boilers), therefore is mandatory to determinate the correct working mode (denominated TYPE) before installation and setting. From the main menu select the TYPE parameter and those are the following option: 2

Description crt Room thermostat working with ON/OFF command to the boiler. Connect the 2 right wires (highlighted with T.A.) to room thermostat connection on the boiler. Maximum switching load of 2A at 30VDC or 0,25A at 230VAC. Boiler remote control using a bus protocol to communicate with the boiler. Connect the 2 right wires (highlighted with OT+.) to remote control connection on the boiler. crs To be used only when boiler is set in a continuous pump running mode. Room thermostat working with ON/OFF command to the boiler. Connect the 2 right wires (highlighted with T.A.) to room thermostat connection on the boiler. Maximum switching load of 2A at 30VDC or 0,25A at 230VAC. Your programmer is a room thermostat (recognized by no house icon on display) type crt Your programmer is a boiler remote control (recognized by house icon on display) type 3

Programming button Fast DHW adjusting buttons ( only) Fast room temperature adjusting buttons Heating mode button 4

Display Adjusting buttons Heating mode button Temperature sensor Battery flap 5

INSTALLATION AND OPERATING INSTRUCTIONS Unlike the conventional thermostat, this control separates the function in two units. The receiver serves for wiring connections and heat on/off control. The transmitter serves as the user interface and for temperature sensing/control. The two units are linked by radio frequency (RF). The transmitter is a wall-mounted timerthermostat. The transmitter can be located wherever a conventional room thermostat would normally be sited. No wiring is required, as the transmitter is battery powered. The receiver is connected to the boiler, and can replace a conventional mechanical or electronic time clock. Important: these instructions should be read in conjunction with the appliance installation instructions. It is recommended that this device is installed by a qualified electrician. PACKING LIST QTY RF receiver with 6 wires fitted 1 RF transmitter 1 Anchors and screws 4 Double side adhesive 3 Instructions 1 Carton internal packaging 1 Batteries 2 NOTE: Eventual additional electronic boards necessary to connect the controller to the boiler main board are not included in this box and need to be purchased separately. PREPARATION: Isolate the appliance from the electrical supply and remove the appliance casing and PCB cover (refer to boiler installation instructions for specific details). Connect the spade terminals of the receiver to the boiler side. The 4 cables have different color and different function. 6

Blue = main supply 230 Vac = neutral N Brown = main supply 230 Vac = line L Black & Black = OT+ boiler remote control connection (bus protocol). Red & Red = T.A. boiler ON/OFF room thermostat connection The choice between the two options (defined as installation TYPE) depend from the boiler capability and from the installer decision. See picture for the receiver internal connections. Important: the link-wire (if fitted) must be removed from room thermostat terminals (both installation type) Important: Secure the receiver wiring harness to the internal boiler cable anchors Important: never connect the OT+ contact to 230V supply to avoid the destruction of the bus circuit. INSTALLATION OF RECEIVER Secure the receiver in the proximity of the boiler using 2 anchors (see picture below for drill holes specifications) and screws or the enclosed double side adhesive. The location should be chosen in order to see the receiver leds and have access to the receiver encoding button. For no 7

reason should the receiver box be opened. The appliance can only be mounted indoors and in areas free from any water or moisture. Wiring must conform to IEE regulations. RF Address Code Setting: if there is another user nearby, e.g. in the next dwelling, your receiver may be operated in error by their transmitter. You may select a different RF address code to prevent this. (see encoding section on the technical menu list). Note: do not fix the receiver to the boiler casing. INSTALLATION OF TRANSMITTER Before installing the transmitter check the encoding functionality while the receiver and the transmitter are still very near. The encoding between the transmitter and the receiver is already factory set therefore there is not necessity to make any encoding operation after installation (both installation type) - follow the encoding instruction if the communication is missing or lost. Before fixing the transmitter check that the radio signal is active in the room that you are fixing (if there is no communication the receiver will flash orange after 350 sec the communication is lost). Because the transmitter uses radio waves to communicate with the receiver, you should also bear in mind that metallic objects can weaken or deflect radio signals: this includes steel reinforced walls, filing cabinets, kitchen appliances, mirrors. The range of the Radiostat is 40 metres in open air, and 20 metres inside buildings, dependent on RF obstructions as mentioned above. 8

Position the Radiostat on a wall surface away from obstructions and direct heat sources or draughts, in a room that is warmed by the heating system. The fixing of the transmitter can be done either with the anchors and screws or with the double sided adhesive (both supplied). See the diagram below as reference to drill the wall. and re-assembly to backplate. Pay attention because it could be difficult to open, follow the diagram for an easier opening procedure. WARNING! DO not touch the printed circuit board of the transmitter as it contains electrostatically sensitive components. In the case of using anchors, the transmitter box must be open to fix the screws to the anchors internally the box. See the diagrams below for removal from FUNCTIONS The Beretta Programmable 7-day RF Thermostat has the following functions: Room thermostat (crt): for the display appearance in this mode, please refer to the relevant section of this manual. The internal temperature sensor detects the temperature and, comparing 9

with the set point, switches ON or OFF the heating request (according the programmed timing). The temperature sensor is located on the left side of the item. Temperatures: there are two level of selectable temperature: Comfort temperature T1 and economy temperature T2 (T1 always > T2). Both are selectable. Additionally there is a third level of temperature indicated as frost protection temperature that is active all the time (the frost protection temperature is selectable only inside the technical menu. T2 always > Frost protection temperature) Time: on the display it is possible to set and read the time (24 hours display mode) Day: on the display it is possible to set and read the day of the week Programming timing: it is possible by selecting the relative timing fascia to select the desired time. The programming is possible during 7 day 24-hours and the minimum time fascia is 30 minutes. The programming is possible in two separated temperatures: COMFORT (T1 ) and ECONOMY (T2 ). Status mode in crt: select the heating mode button for fast switching between the 4 status OFF AUTO PARTY - HOLIDAY. OFF mode, the heating request to the boiler is off, on display there is not equivalent icon, the heating layer and the programming fascia is off. With this mode only the frost protection function is active. AUTO mode: the heating request is according the programmed timing and 10

room temperature. In AUTO mode it is possible to increase or decrease temporary the room set temperature by pressing the and buttons, only if the current time is inside in a heating ON fascia. The temporary new temperature set (T1) is maintained only inside the timing fascia. The next heating fascia will be back to the original T1 set temperature. It is possible to check the set temperature by pressing once the or the buttons only if the current time is inside in a heating ON fascia. HOLIDAY mode with choice how many day off (by increasing or decreasing using the button and ). The heating request to the boiler is to maintain the economy temperature on the room (T2). The number of days off is considered on the day starting from midnight. After the counter down is ended the programmer switch to AUTO mode. PARTY mode automatically switch the programmer ON to comfort temperature (T1). This status is forced up to midnight, after, the programmer goes back to the programmed timing fascia. Remote Control (): for the display appearance in this mode, please refer to the relevant section of this manual. The internal temperature sensor detects the temperature and, comparing with the set point, calculates the most suitable boiler flow temperature according the climatic curve (only if the external sensor is fitted) and according the velocity the set temperature is reached. The programmer continuously communicates with the boiler control indicating the target flow temperature (the 11

values not just an ON/OFF) according to the calculation made. With this type of communication it is possible also to adjust by remote the domestic hot water (DHW) temperature in case of instantaneous DHW production or DHW storage tank controlled by a dedicated sensor. The functions of this type () are the same as room thermostat type above described. Additionally it is possible to have a feedback from boiler status and alarms. The display in type give more information according the already mentioned start up indications. The 4 status mode have additional functionality compared with the type room thermostat. Status mode in : select the heating mode button for fast switching between the 4 status OFF AUTO PARTY - HOLIDAY. OFF mode, the heating request to the boiler is off, on display there is not equivalent icon, the heating layer and the programming fascia is off. With this mode only the frost protection function is active. The DHW function is active and it is possible to increase or decrease the target temperature by pressing the and buttons. AUTO mode: the heating request is according the programmed timing and room temperature. In AUTO mode it is possible to increase or decrease temporary the room set temperature by pressing the and buttons, only if the current time is inside in a heating ON fascia. The temporary new temperature 12

set (T1) is maintained only inside the timing fascia. The next heating fascia will be back to the original T1 set temperature. It is possible to check the target flow temperature communicated to the boiler (according the various calculations) by pressing once the buttons only if the current time is inside in a heating ON fascia. In the case the outside sensor is fitted (external temperature displayed) the and buttons increase or decrease of equivalent degree indicated on display, the room comfort level (from 5 to +5) (T2). The number of days off is considered on the day starting from midnight. After the counter down is ended the programmer switch to AUTO mode. PARTY mode automatically switch the programmer ON to comfort temperature (T1). This status is forced up to midnight, after, the programmer goes back to the programmed timing fascia. Other functions (common to crt and modes): Battery low Alarms and reset (only for type) Technical menu (only for experts) HOLIDAY mode with choice how many day off (by increasing or decreasing using the button and ). The heating request to the boiler is to maintain the economy temperature on the room 13

OPERATING INSTRUCTIONS The programmer is factory set as room thermostat type (crt). Most of the parameters are already set, at the start up it is necessary to set the time and the day (please note no summer time is precharged inside therefore if during the year there is time modification it must be adjusted). The following operation must done at start up the scrolling give access to the following settings: Attention: the TYPE of the device (that is part of the main menu selection) should have already been set by the installer as this set is according the installation made (ON/OFF device T.A. or Remote Control device OT+). END USER MENU (MAIN MENU) Enter inside the end user menu pressing the button once. Use the button to escape at any time. Scroll inside the end user menu pressing any of the triangle buttons and press again the button to enter inside the single setting, 14

icon Description Factory set Setting the comfort (T1) and economy (T2) temperatures T1 = 21 C T2 = 16 C Setting the time Unset Setting the day Unset Setting the programming fascia to switch between T1 and T2. The value selected is automatically Unset Setting the domestic hot water temperature (only type) 42 C type Setting the TYPE crt PL Setting the technical menu (password required) -- Setting the Domestic hot water programming daily fascia (only with boiler with tank and parameter 24 ON and only in -- 24hr time) memorized moving at the next setting. Set the target room temperature Use the button to enter and exit. (T1 and T2). Use the and to Set the time. Use the and increase or decrease, use the and to increase or decrease, use the and to switch between hours and 15

minutes. Use the button to enter and exit. Set the day of the week. Use the and to increase or decrease. Use the button to enter and exit. Set the programming heating fascia. Use the to select the day (only ahead, not back). Use the to switch ON or OFF the layer T2 or T2+T1, once selected maintain the copy to the following 30 minutes pressing the button. Move ahead or back the point using the and buttons. Heating fascia are pre-set with day 1-5 from 6-8,30 and from 16 to 22 on T1and days 6-7 from 8-11 and from 16 to 23 on T1. The setting is made on 30 minutes Set the target domestic hot water. Use the and to increase or decrease the value. Use the button to enter and exit. type Set the device installation type. Use the and to switch between the values (see the table at page 2 for details). PL Enter inside the technical menu. Password required. Use the and to increase or decrease the password code. (see specific paragraph for better details) Set the daily programming fascia for domestic hot water production (only for boilers installed with tank and sensor). Parameter active only if the parameter 24 inside the technical 16

menu is set ON. Set the programming fascia in the same way used for heating fascia. The setting is possible daily, not weekly. The heating of the DHW tank will be done according the selected programmed fascia. Battery low When the controller feels that the battery are about to be exhausted, the battery icon will lit up. In this case the batteries needs to be changed in due time. If the battery completely run out of energy, or during the battery replacement, the settings will be kept in the controller memory, except for the time and the day ALARMS Should anything occur during the functioning of the controller, a display will be shown in the main display, together with the spanner icon. In most of the cases it is sufficient to press the button to reset the system, but exceptions apply according to the following list: ALARMS RELATED TO THE CONTROLLER The following are alarms related to the controller only: A80 = room sensor broken. Replace the controller A81 = EEPROM alarms. Following this alarm after the reset, the set of factory parameters are recharged in the controller memory A82 = no radio communication with the receiver ( or crt mode) A83 = (only for mode) the cable between the receiver and the boiler is broken or not connected properly. There 17

is no communication between receiver and boiler. Or receiver connected on the room thermostat (T.A.) boiler connection. A99 = too many resets. There have been more than 5 resets in 15 minutes. Following this alarm, it is necessary to reset the boiler directly on its dashboard and is not possible to do it from the controller. ALARMS RELATED TO THE BOILER (ONLY REC TYPE): The alarms are displayed as per the display of the boiler: refer to the boiler instruction manual for the meaning of the symbols. REMARK: the alarms type A2X can be reset only from the boiler fascia. CLIMATIC CURVES Below the climatic curves of the programmer. Curves from 0,2 to 0,8 are used when the boiler is set for low temperature (i.e. floor heating). Curves from 1 to 3 are used when the boiler is used for high temperature (i.e. radiator heating), Selection of the climatic curve can be made inside the technical menu only. The climatic curve function is active only if an external sensor if fitted to the boiler. If there is not external sensor fitted, the programmer make an automatically regulation using the room sensor. ALARMS RESET The reset of the alarms is done pressing the button on the RF receiver 18

Boiler flow temperature External temperature DISPLAY IN crt (ON/OFF) MODE: When the device is in its standard mode of functioning, the appearance of the display will be the following: The icon means that the device is set as a wireless device, and that the communication is effective The icon means that there is a heat request from the room to the boiler. The boiler will switch ON. The central heating symbol and bar is a proportional indication of the set-point of the desired temperature in the room. Each bar represents to 2 C. They will disappear when the central heating is turned OFF. 19

The temperature display indicates the actual temperature measured inside the room The time display indicates the actual time The day icon indicates the actual day of the week The central heating fascia bar is a permanent display of the functioning fascia set for the central heating set point setting. If a bar is completely blank, the set-point is the anti-frost level (central heating OFF). If only the lower part of a bar is black, the set point is the economy (T2). If the whole bar is black, the set point is the comfort (T1). They will disappear when the central heating is turned OFF. The day icon and the night icon indicate whether the current set point for the current time is night or day. The party icon is lit up when the party mode is selected. In this mode the central heating fascia bar will be completely lit up at T1 together with the day icon. After midnight, the display will turn back to the pre-set working fascia. The holiday icon is lit up when the holiday mode is selected. In this mode the central heating fascia bar will be lit up at T2 together with the night icon. After the holiday counter is over, the display will turn back to the pre-set working fascia. 20

When the icon appears, the controller is working as to keep the anti-frost temperature. DISPLAY IN (remote control) MODE: When the device is in its standard mode of functioning, the appearance of the display will be the following: The icon means that the device is set as a wireless device, and that the communication is effective The icon means that there is a heat request from the room to the boiler. The boiler is ON with flame present. The central heating symbol and bar is a proportional indication of the set-point of the desired temperature in the room. Each bar represents to 2 C.They will disappear when the central heating is turned OFF. In case of external sensor fitted, the bar is moved up and down according the room comfort level chosen. 21

The temperature display indicates the actual temperature measured inside the room The house icon around the temperature display, indicates that the controller is set as a Remote Control () and appears only in this mode of functioning. The display on the right side of the house indicates the external temperature reading, and it appears only when the outdoor sensor is correctly connected. The central heating fascia bar is a permanent display of the functioning fascia set for the central heating set point setting. If a bar is completely blank, the set-point is the anti-frost level (central heating OFF). If only the lower part of a bar is black, the set point is the economy (T2). If the whole bar is black, the set point is the comfort (T1). They will disappear when the central heating is turned OFF. The day icon and the night icon indicate whether the current set point for the current time is night or day. The domestic hot water symbol and bar is a proportional indication of the setpoint of the desired temperature when the boiler works in domestic hot water mode. Each bar represents 1 C. 22

The party icon is lit up when the party mode is selected. In this mode the central heating fascia bar will be completely lit up at T1 together with the day icon. After midnight, the display will turn back to the pre-set working fascia.the holiday icon is lit up when the holiday mode is selected. In this mode the central heating fascia bar will be lit up at T2 together with the night icon. After the holiday counter is over, the display will turn back to the pre-set working fascia. When the icon appears, the controller is working as to keep the anti-frost temperature. TECHNICAL MENU The device has the possibility to set a series of parameters to better adapt the controller to the installation. Following instructions are dedicated to expert personnel as they have a deep impact on the working mode of your boiler and your system. To enter inside the PL menu it is requested a password. From the end user menu, select the PL pressing the button. Increase or decrease the values up to reach the value 53 (that is the technical menu password). Once reached the value 53, press the button to enter. You are now inside the technical menu (only for expertise). Use the and to scroll the parameters list, below the sequence and the explanation of each parameter. Note: the visibility of the parameters depends of the type selected. 23

Par. Ref. 01 Descr. Encoding procedure Factory set value codified and crt Operation Display shows the wireless channel and the address. Use the button to start the encoding procedure. On the receiver press for 5 second the button up to the orange light is flashing, the transmitter start to codify all the values and the display shows P00..-P90. After reaching the P90 value the encoding procedure is done and the light on the receiver stops to flash. 08 Max set point heating 85 C (30 C 85 C) only Use the button to decrease and the button to increase the temperature value. The value is automatically memorized when moving to the next parameter. This parameter put a high limit on the maximum temperature value communicated to the boiler. 09 Min set point heating 30 C (30 C 85 C) only Use the button to decrease and the button to increase the temperature value. The value is automatically memorized when moving to the next parameter. This parameter put a low limit on the minimum temperature value communicated to the boiler. 24

Par. Ref. Descr. Factory set value Operation 10 Climatic curve selection 1.2 (see climatic curves) only Use the button to decrease and the button to increase the climatic curve value (see below the climatic curves). The value is automatically memorized when moving to the next parameter. 11 Influence of temperatur e sensor 10 (0 20) only Use the button to decrease and the button to increase the influence of room sensor on the calculation of the boiler flow temperature. 10 is the standard, higher values is good for pour insulation houses. The value is automatically memorized when moving to the next parameter. 13 Calibration of the room sensor Actual and crt Use the button to decrease and the button to increase the reference room temperature. Use this parameter in case of not proper installation of the device. The value is automatically memorized when moving to the next parameter. 14 Programm er reset 0 and crt Use the button to move to value 1 and reset the device to a factory set values. Press the button to confirm the reset. 25

Par. Ref. 16 Descr. Software release Factory set value Actual and crt Operation This parameter just shows the software reference number on the device 17 Choice C or F C and crt Use either the button and the button to switch to F or C. all the temperatures values will change. In case of F values there is not equivalent letter F displaye d The value is automatically memorized when moving to the next parameter. 18 Hysteresis OFF 0.1 C (0.0 2.0) and crt Use the button to decrease and the button to increase the hysteresis OFF of the device. The value is automatically memorized when moving to the next parameter 19 20 Hysteresis ON Frost protection temp. 0.5 C (0.0 2.0) 5 C (3 C 10 C) and crt and crt Use the button to decrease and the button to increase the hysteresis ON of the device. The value is automatically memorized when moving to the next parameter Use the button to decrease and the button to increase the frost protection temperature limit. The value is automatically memorized when moving to the next par. 26

Par. Ref. 21 22 23 Descr. Alarms history Boiler TSP reading Anti- Legionella function Factory set value Actual Actual OFF only only only Operation Use the and the button to scroll last 9 alarms code memorized on the device. Unused Use the and the button to switch ON or OFF the legionella function (function active only with boiler connected to a tank with sensor control). 24 Clock on DHW OFF only Use the and the button to switch ON or OFF the programming time on the DHW production via a tank with sensor. (function active only with boiler connected to a tank with sensor control). If selected ON, on the end user menu will appear a dedicated programming fascia to be set (programmable daily fascia only) 27

TECHNICAL SPECIFICATIONS LIMIT OF SETTING OF THE TEMPERATURES: Anti-frost temperature: 3 C 10 C T2: anti-frost temperature 35 C T1: T2 35 C DHW (if applicable): 37 C 60 C Room temperature: 5 C 30 C READING LIMITS Outdoor sensor: -10 C 40 C Room sensor: -10 C 40 C RECEIVER Linked with transmitter via RF: frequency 868 MHz Power rating: 230 VAC ± 10%, 50 Hz T.A. Switching capacity (crt only): Min 1mA, Max 2A at 30 VDC Max 0,25A at 230 VAC OT+ contact: for bus protocol only. Never supply with 230V this contact. TRANSMITTER Linked with receiver via RF: frequency 868 MHz Power rating: 2 x 1,5AA - Alkaline batteries Install transmitter and receiver in an environment with normal pollution level. Radio range 40 m in free space, (the range can be altered depending on the installation conditions and on the electromagnetic environment). Beretta -Via Risorgimento 23/A 23900 Lecco (Italy) www.berettaclima.com Beretta reserve the right to change specification without prior notice - Consumers statutory rights are not affected. A Riello Group Company Manual Issue 08/2012 rev.01 28