Dual System with 2x Independent Channels each of :

Similar documents
Single Channel Video Transmit Unit with one Bi-directional Data Channel and two Uni-directional Alarms for a Multimode Fibre Link

Single Channel Video Receive Unit with two Bi-directional Data Channels and one Bi-directional Alarm Channel for a Multimode Fibre Link

Four channel video link For low cost video transmission

ACCURATE ELECTRONICS INC

RC801/803/ B 16E1 Fiber-Optic Multiplexer (Rev. M) User Manual. Raisecom Technology Co., Ltd. (04/2005)

C-Bus Four Channel General Input Unit Installation Instructions

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG. LD-64 Profibus

VPS3 Installation Manual

5000 INSTALLATION GUIDE

Instruction Manual Model L2 RF Switch

RC802/ B 8E1 Modular Fiber-Optic Multiplexer (Rev. M) User Manual

RS485 MODBUS Module 8AI

VDS2510 Installation Manual

Erbium-Doped Fiber Amplifier (EDFA) - MW Series

RION ORION TELECOM NETWORKS INC. E2, 2Mbps x 4 Opti-Multiplexer Integrated E2, OLTE and Multiplexer. Product Brochure & Data Sheet TELECOM NETWORKS

SA100. General Description. Features. Temperature Controller SA100. Corresponding to Various Applications. Simple Mounting on DIN Rail

General Routing Interface

AUTO SWITCH ALARM PS1 PS2 CH2 MANUAL REMOTE HISTORY ALARM ONLINE AUTO MANUAL SELECT SWITCH RESET

MODEL 8143 SIGNAL SELECTOR INSTALLATION AND OPERATION MANUAL

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

DIVA8MG2. Compact PAVA System Master Unit. DIVA8 System

IF-L/RF Protection Switch

21-light Remote Annunciator. Owner s Manual

Revision November 2013 JVA Technologies. Ethernet General Purpose IO Technical Manual

600 Range Dialer Installation Manual. Version 1.0

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

LCP-6144A4EDRx. 10GBASE-SR SFP+ Optical Transceiver FEATURES. Description. Applications. RoHS compliant. Compliant to SFP+ Electrical MSA SFF-8431

INSTALLATION INSTRUCTIONS

Fibre Optic Basics FIA Summer Seminar 2014

Instruction Manual Model Backup Switch, 1 for 8

MODEL 8144-RD CLOCK SELECTOR/DISTRIBUTION AMPLIFIER INSTRUCTION MANUAL. SPECTRACOM CORPORATION 95 Methodist Hill Drive, Suite 500 Rochester, NY 14623

HRX Technical Manual. Version 1.2

ADDENDUM. xwatch Explosion-Proof Camera with X-Series Flame Detectors DESCRIPTION GENERAL APPLICATION INFORMATION

ANNUNCIATOR INSTRUMENTS Model PD141AFO Instruction Manual

INSTRUCTION MANUAL and DETAILED PRODUCT SPECIFICATION TRIPLEX PUMP CONTROL SYSTEM MODEL NUMBER CPC-3. M336 Rev F. November 21, 2000.

DigiAir QUICK GUIDE & INSTRUCTION MANUAL

Fratech Multipath-IP

USER MANUAL FOR OPERATING SYSTEM

TECHNICAL DATA SHEET ADDRESSABLE FIRE ALARM SYSTEMS FIRE ALARM CONTROL PANEL LF-6100 A 1/2

Ethernet General Purpose

STATUS ALARM HISTORY ALARM RESET

SA200. General Description. Features. Temperature Controller SA200. Self-Tuning Algorithm. Close Vertical or Horizontal Mounting

LED Driver Module. These instructions contain procedures to follow in order to avoid personal injury and damage to equipment.

NT DUAL CHANNEL DISPLAY. User Guide

FPS CL Burst Mode SFF BIDI EPON ONU TRANSCEIVER(20Km)

IRIS Touch Quick Installation & Maintenance Guide. Version 1.0

Pakton Technologies Pty Ltd ABN Ferrier Road, Narangba Qld 4504

MEMS Accelerometer ICs. AMR Magnetic Sensor ICs. Gas Flow Modules. Differential Pressure Sensors. Tilt Modules. Current Sensors

HOA1888 Series. Infrared Assemblies Wide Gap Transmissive Sensor. MICRO SWITCH Sensing and Control

I/A Series 716C 1/16 DIN Temperature Controller

Advanced Test Equipment Rentals ATEC (2832) LS-1310/1550 Laser Source. Service Information Sheet.

GE Security. FP1200, FP2000 and KSA1200 series fire panels, repeaters and emulators Interconnection and wiring

OVEN INDUSTRIES, INC.

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

KT-100 Door Controller

P2267 NETWORK INTERFACE

ACCURATE ELECTRONICS INC PO BOX SW HALL BLVD BEAVERTON OR USA FAX

SCR100 User Manual. Version:1.1 Date:Dec 2009

STATUS ALARM ALARM HISTORY POWER HISTORY RESET

English. Italiano. Português. Françias. Español


SMART Dust Sensor. Amphenol Advanced Sensors SM-PWM-01C. Application Note. Features

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Rig Protector. Multipoint Critical Gas Detection and Monitoring System

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

LC1350 Level Controller

LCP-10G3B4QDRx-G. 10GBASE-LR SFP+ Optical Transceiver FEATURES. Description. Applications. Performance. RoHS compliant

General Purpose IO Technical Manual

SIMATRIX NEO Modular Video Matrix

Replaced by A5367CA. DISCONTINUED PRODUCT SMOKE DETECTOR WITH INTERCONNECT AND TIMER FEATURES


Optical Smoke Detector Heat Detector Manual Call Point Output Unit Isolator

T3/E3 Fiber Optic Line Drivers

EMS510 Electrical Wiring Guide Volume 2, Rev 1.4

Operation Manual Part-No

D3000. Installation & Setup Guide

Fire Control Panels. Multiple Signal Fiber Optic Modems and Accessories for Panel and Remote Mounting. Features. Operation.

M2500 Engine Controller Installation Manual

Series 65 Product Guide MAN 3036

DESCRIPTION INSTALLATION

DS7465i. Installation Instructions. Input/Output Module

Unipoint controller. The Unipoint, a simple DIN rail mounted controller

How to use the BTRM in Remote Enclosures

LCP-10G3B4HDR(T)-G. 10GBASE-LR Lite SFP+ Optical Transceiver. Description. Applications. Performance FEATURES. RoHS compliance

EOTec 2C32 Installation Guide

HDCVI PIR Camera User s Manual

INSTALLATIONSANVISNING INSTALLATION MANUAL INSTALLATIONS ANLEITUNG LD-64F

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Ohm Metrics. Instruction Manual. Continuous Workstation Monitors Model CM1600. T r a n s f o r m i n g T e c h n o l o g i e s, L L C

An introduction to... Sigma

Model AD C AD RS-422 Distributor

Installing the Cisco ONS FAP-4 Fuse Alarm Panel

MT-RJ Optical Fiber System Field Testing

DAWN Electronics, Inc.

Installation Guide and Operating Manual MAN0932_V1_ _Rev B_08-12

Zareba Unipoint controller

DISCONTINUED PRODUCT. For reference only SMOKE DETECTOR WITH INTERCONNECT FEATURES. ABSOLUTE MAXIMUM RATINGS (Voltages are referenced to V SS

OFS IV Optical Fibre System

AFMS Audible Flow Monitoring System TECHNICAL SPECIFICATION

DDT-4691 & DDR ASI / SD-SDI 8 Channel Mux Fibre Optic Link. User Manual. IRT Electronics Pty Ltd

Transcription:

AMG5723 Instruction Manual Dual System with 2x Independent Channels each of : [Single Transmit Unit with one Bi-directional Data Channel plus one Bi-directional Alarm for a Singlemode Fibre Link] The AMG5723 is a DUAL standalone system which provides two independent channels, each designed to transmit one video signal and transmit and receive one bi-directional alarm plus one data signal over one Singlemode optical fibre. The AMG5724 is designed to be powered using an AMG2001 standalone power supply. The AMG5723 is designed to operate with two AMG5714 / AMG5714R single channel or one AMG5724 or AMG5724R dual channel video receive unit in a point to point configuration. The R suffix in the partno. indicates a rackmount configuration. Page 1 of 8 AMG5723 Instruction Sheet D17061-

Contents Introduction 3 Unit Functional Schematic... 3 Optical Connection... 3 Connections 4 Video Input Connections... 4 Optical Connections Singlemode... 4 Power Connection... 4 Data and Alarm Channel Connections... 4 Front Panel Indicators 5 Power LED... 5 Low Speed Data LEDs... 5 Alarm LEDs... 5 Data and Alarm Channel Configuration 6 Data Channel Configuration... 6 Data Interface Connections... 7 Alarm Channel Configuration... 7 Alarm Interface Connections... 7 Physical Information 8 Dimensions... 8 Mounting Details... 8 Safety 8 Maintenance and Repair 8 Page 2 of 8 AMG5723 Instruction Sheet D17061-

Introduction Unit Functional Schematic The AMG5723 provides two independent, transmit channels. Each channel transmits one video signal plus 1 data and 1 bi-directional alarm signal to an AMG5724 receive unit. It also receives 1 data and 1 bi-directional alarm signal from the AMG5724. The schematic diagram shows one of the two available channels of the AMG5723 Optical Connection The AMG5723 connections are illustrated in the following example which shows an AMG5723 transmit unit together with an AMG5724R two channel standalone receive unit configured as a dual channel point to point system. Page 3 of 8 AMG5723 Instruction Sheet D17061-

Connections Video Input Connections No. of channels...2 Connector...75 ohm BNC Socket. Input Impedance...75 ohm terminated. Input Level...1 volt p-p nominal Frequency Response...10Hz to 7MHz. Optical Connections Singlemode No. of Optical Connections...1 per video channel Optical Fibre...Singlemode Connector...SC/PC Primary Optical Launch Power...-10dBm Transmit Wavelength...1310nm Primary Optical Sensitivity...-30dBm Receive Wavelength...1510nm Minimum Optical Dynamic Range...20dB. Power Connection Connector Type...Removable 2-pin, 3.81mm, Screw Terminal Connector Partno...Phoenix 1803578 Supply Voltage...+12 to +15 Volts DC Maximum Power...2.5 Watts Data and Alarm Channel Connections No. of Data Channels...1 per video channel. No. of Alarms...1 bi-directional alarm per video channel. Connectors...Removable 8-pin, 2.5mm, Screw Terminal Connector Partno...Phoenix 1881383 Data Interfaces...RS-232, RS-422 or R-S485. Selected by slide switch inside enclosure. *See appropriate section on how to remove the case for access to the data switches RS-485 Switch Position - Top RS-422 Switch Position - Middle RS-232 Switch Position - Bottom Alarm Input...Contact Closure pull-up is 330R to +3V3 Alarm Output...Solid-state Relay, maximum 150mA at 125Vac/dc, Ron < 6.5Ω Page 4 of 8 AMG5723 Instruction Sheet D17061-

Front Panel Indicators Power LED Power / Video / Opto... Green - Video present & opto sync. R/G - Opto sync. but no video present. G/R - Video present but no opto sync. Red - No opto sync. Off - No power applied to unit Low Speed Data LEDs Data Present IN (RS485 or RS422)...Green - logic zero (+V, -V) present on IN+, IN- Red - logic one (-V,V+) present on IN+, IN- Off - tri-state off or no connection on IN+, IN- Data Present IN (RS232)...Green - logic zero (+V) present on input IN+ Red - logic transitions present on input IN+ Off - logic one (-V) present on input IN+ IN corresponds to the data signals being transmitted onto the optical fibre. Data Present OUT (RS485 or RS422) Green - logic zero (+V,-V) present on OUT+, OUT- Red - logic one (-V,+V) present on OUT+, OUT- Off - tri-state off or no connection on OUT+, OUT- Data Present OUT (RS232)...Green - logic zero (+V) present on OUT+ Red - logic transitions present on OUT+ Off - logic one (-V) present on OUT+ OUT corresponds to the data signals being received from the optical fibre. Alarm LEDs Channel 1 ALARM IN...Green - Alarm ON / Contacts closed. Off - Alarm OFF / Contacts open. ALARM OUT...Green - Alarm ON / Contacts closed. Off - Alarm OFF / Contacts open. Channel 2 ALARM IN...Green - Alarm ON / Contacts closed. Off - Alarm OFF / Contacts open. ALARM OUT...Green - Alarm ON / Contacts closed. Off - Alarm OFF / Contacts open. Page 5 of 8 AMG5723 Instruction Sheet D17061-

Data and Alarm Channel Configuration The AMG5723 sends and receives data to/from up to two AMG5714 single channel or one AMG5724 dual channel receive unit or rackmount equivalent. Each physical data interface RS-485, RS-422 or RS-232 is individually selectable by the user with the corresponding slide switch mounted on the main PCB inside the enclosure. One bi-directional alarm is also provided for each video channel. The alarm input is typically connected to a contact closure switch. The alarm output can receive an on/off signal from an AMG5724 and is typically used to convey contact closure status. Data Channel Configuration Each low speed data channel provides an RS-232, RS-422 (full duplex, four wire) or RS-485 (half duplex, two wire) interface defined by the corresponding mode switch inside the enclosure. Every data channel as shipped from the factory is set up for RS-485 operation unless otherwise requested. The data input for both the RS-485 and the RS-422 modes detects a tri-state input condition by monitoring the differential voltage level across the input. A differential level below 600mV positive or negative will be detected as a tri-state condition. A level above 600mV positive or negative will be detected as a logic 1 or logic 0 respectively. It is important therefore to terminate the RS-485 bus or the RS-422 input bus using 120Ω if a pre-bias is present on the RS-485 or RS-422 bus. A large number of third party equipment manufacturers apply a pre-bias on their RS-485 bus. This prebias is applied by pulling one arm of the RS-485 bus high (+5 volts) and the other arm low (0 volts) using high value resistors within the third party equipment. In order to ensure that the AMG equipment detects a tri-state condition, then these resistors should have a value above 5kΩ. If the third party bias resistors are less the 750Ω the bus can be multiple terminated as required to ensure that a tristate level is detected. The system detects a tri-state input condition on the data channel bus when in RS-485 or RS-422 mode. Page 6 of 8 AMG5723 Instruction Sheet D17061

Data Interface Connections Data Channels 1 and 2. Data Channel Connector Pin No. 1 RS-422 [switch middle] IN + (A) 2 IN - (B) 3 RS-485 [switch top] GND GND 7 IN/OUT + (A) OUT + (A) 8 IN/OUT - (B) OUT - (B) RS-232 [switch bottom] IN GND 4 5 6 OUT Note: (A) or (B) in brackets in the above table refers to RS-485 / RS-422 data specification. Alarm Channel Configuration The AMG5723 provides 1 bi-directional alarm output / contact closure input per video channel. The alarm input is typically connected to a contact closure switch. An ALARM IN+ input incorporates a 330R pull-up resistor to the internal +3V3 supply. The alarm output can receive an on/off signal from an AMG5724 and is typically used to convey contact closure status. An alarm output uses a solid-state relay, with a maximum load current of 150mA at 125Vac/dc and Ron < 6.5Ω. Alarm Interface Connections Video Channels 1 & 2 Alarm Interface Connector Alarm IN Alarm OUT Pin No. 1 2 3 GND 4 ALARM IN + 5 ALARM OUT - 6 ALARM OUT + 7 8 Page 7 of 8 AMG5723 Instruction Sheet D17061

Physical Information Dimensions Height...132mm Width...172mm (excluding connectors) Depth...35mm Weight...500grams Mounting Details The unit is designed to be mounted on a panel using 4 off 4.0mm screws, see diagram on page 1. Safety AMG Optical Fibre Products use Class 1 laser systems in accordance with EN 60825-2:2000. It is always advisable to follow good practice when working with optical fibre systems. This includes: Do not stare with unprotected eyes or with any unapproved collimating device at fibre ends or connector faces, or point them at other people. Use only approved filtered or attenuating viewing aids For other safety issues and advice on good practice associated with optical fibre systems, please see EN 60825-2:2000 or your local safety officer. Maintenance and Repair There are no user serviceable parts within AMG products. See unit data sheet for full specification. In case of problem or failure, please call your local support centre or contact: AMG Systems Ltd. at 3 The Omega Centre, Stratton Business Park, Biggleswade, Beds., SG18 8QB, UK. Phone Technical Support Email +44 (0) 1767 600 777 +44 (0) 1767 604 491 techsupport@amgsystems.com Page 8 of 8 AMG5723 Instruction Sheet D17061