Multi V Air Conditioner SVC MANUAL(Exploded View)

Similar documents
Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi Zone Air Conditioner SVC MANUAL (Exploded View)

Multi Zone Air Conditioner SVC MANUAL (Exploded View)

Hydro Kit (For Medium Temperature) SVC MANUAL(Exploded View)

Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Wall Mounted Air Conditioner SVC MANUAL(Exploded View)

(60Hz/R410A) 6CIM0-02B (Replace: 6CIM0-02A)

SVC Manual(Exploded View)

LG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static)

Room Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Air Conditioner SVC MANUAL(Exploded View)

Single Zone Air Conditioner SVC MANUAL(General)

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F)

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01J (Replace: 5BPM0-01H)

SVC Manual(Exploded View)

INDOOR UNIT PRODUCT OVERVIEW

Single Zone Air Conditioner SVC MANUAL (Exploded View)

Air Conditioner CONTENTS

DESIGN & TECHNICAL MANUAL

CU-B24DBE5 CS-F28DTE5 CU-B28DBE5 CS-F28DTE5 CU-B28DBE8 CS-F34DTE5 CU-B34DBE5 CS-F34DTE5 CU- B34DBE8 CS-F43DTE5 CU-B43DBE8 CS-F50DTE5 CU-B50DBE8,

Multi Air Conditioner Indoor Unit SVC MANUAL(General)

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

Single "A" Air Conditioner SVC MANUAL(General)

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

Highly Efficient,Powerful Heating and Cooling.

Ceiling Cassette Type Single-Zone Air Conditioning

DESIGN & TECHNICAL MANUAL

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

duct-free air conditioning systems Art cool inverter flex multi-split

New Wide Wired Remote Controller

ENGiNEERiNG AND SPECiFiCATioNS GuiDE

Service Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

Multi Type Room Air Conditioner

SIMPLE WIRED REMOTE CONTROLLER

Engineering Data Book

AIR CONDITIONER INSTALLATION MANUAL.

DESIGN & TECHNICAL MANUAL

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

SUBMITTAL M4MCW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MCW1509A1N0A M4TCS1509A11NA TAG:

Weekly Wired Remote Controller

Single-Zone Four-Way Ceiling-Cassette System Engineering Manual

ENGiNEERiNG AND SPECiFiCATiONS GuiDE

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Engineering Data Book

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

FALCON Rooftop Units ACPSE 50/60Hz Cooling Capacity : 36 to 1388 MBH (11 to 407 kw) Heating Capacity : 40 to 1298 MBH (12 to 380 kw)

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Single "A" Air Conditioner SVC MANUAL(General)

Weekly Wired Remote Controller

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

Engineering Data Book

V ~, 50Hz 1Ph. High Wall Split Systems Heat Pump 9K - 12K - 18K - 24K - 28K. Auto. Auto Fan Speed. Auto. Smart LCD Wireless Control.

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

FLOOR STANDING, CEILING SUSPENDED, AND CONVERTIBLE SURFACE MOUNTED INDOOR UNIT ENGINEERING MANUAL

Room Air Conditioner Service and Parts Manual

3. INDOOR UNIT OPERATION

Engineering Data Book

DESIGN & TECHNICAL MANUAL

Up to SEER 26.1 Wall Mount Heat Pump

Engineering Data Book

DESIGN & TECHNICAL MANUAL

SUBMITTAL M4MHW1509A-SUB-1B. Specifications 15 SERIES. Single Zone Mini-Split Inverter System M4MHW1509A1N0A M4THS1509A11NA TAG:

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

manuflow AIR CONDITIONING & HEAT PUMP PRODUCTS SEER 17

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

SERVICE MANUAL MUZ-D30NA MUZ-D30NA- U1 MUZ-D36NA MUZ-D36NA- U1 MUY-D30NA MUY-D36NA OUTDOOR UNIT. No. OBH502. Wireless type Models HFC R410A

AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-02A(5BPU0-01A)

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

Easy to service. Up to 9 indoor units can be connected

Air Conditioning System

SiUS091601E Inverter Pair Wall Mounted Type FTX-N Series Floor Standing Type FVXS-N Series [Applied Models] Inverter Pair : Heat Pump

TECHNICAL CATALOGUE MONO SPLIT RAK-25PSC RAK-35PSC RAC-35WSC

SERVICE MANUAL MSZ-GL06NA - U1 MSZ-GL09NA - U1 MSZ-GL12NA - U1 MSZ-GL15NA - U1 MSZ-GL18NA - U1 MSZ-GL24NA - U1

AUS-DU112. New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 2766 PH : FAX :

C&H NORDIC Commercial 4 SERVICE MANUAL

SINGLE-ZONE CEILING-CONCEALED DUCTED SYSTEM ENGINEERING MANUAL

Submittal Data Sheet

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-03A(Replace:5BPU0-02A)

SiUS181631EA. Service Manual. Multi-Split Type Air Conditioners RMXS-L Series. [Applied Models] Inverter Multi : Heat Pump

Hi - Wall Split Systems. Super Quiet. Auto. Mode. Wireless Control. Smart Airflow ECO ECO. Function SLEEP. Vertical Auto Swing.

Transcription:

Internal Use nly http://biz.lgservice.com Multi V Air Conditioner SVC MANUAL(Exploded View) MDEL : ARNU05GSB*4 ARNU07GSB*4 ARNU09GSB*4 ARNU12GSB*4 ARNU15GSB*4 ARNU18GSC*4 ARNU24GSC*4 CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual. nly for authorized service personnel.

1.Specification (SB chassis) Indoor Type Model Unit kw Cooling Capacity kcal/h Btu/h kw Heating Capacity kcal/h Btu/h Dimensions mm Body (W D H) inch Rows x Columns x FPI Coil Face Area m 2 (ft 2 ) Type Motor utput x Number W Running Current A Fan CMM Air Flow Rate(H) CFM Drive Motor type Temperature Control Sound Absorbing Thermal Insulation Material Air Filter Safety Device Liquid Side Pipe Gas Side Connections Drain(ID) Net Weight Gross Weight Noise Level(Sound Press, 1m, H/M/L) Power Supply Refrigerant Control Power cable Transmission Cable kg(lbs) kg(lbs) db(a)+1 Ø, V, Hz mm 2 No. mm 2 No. ARNU05GSB*4 1.6 1 400 5 500 1.8 1 500 6 100 895x285x205 351/4x117/32x81/8 2 16 23 0.21(2.26) Cross Flow Fan 20 1 0.16 6.5/6.0/5.5 230/212/194 Microprocessor, Thermostat for cooling and heating Foamed polystrene Resin Net(washable) 16(5/8) 10.8(23.8) 12.9(28.4) 30/29/28 1, 220 ~ 240, 50 1, 220, 60 CVVSB 1.0 ~ 1.5 2C * Model name(art Cool Type Panel Color) R:Mirror, W:White, V:Silver Art Cool ARNU07GSB*4 ARNU09GSB*4 2.2 2.8 1 900 2 400 7 500 9 600 2.5 3.2 2 200 2 800 8 500 10 900 895x285x205 895x285x205 351/4x117/32x81/8 351/4x117/32x81/8 2 16 23 2 16 23 0.21(2.26) 0.21(2.26) Cross Flow Fan Cross Flow Fan 20 1 20 1 0.16 0.16 7.0/6.5/5.5 8.2/7.0/5.5 247/230/194 289/247/194 Microprocessor, Thermostat Microprocessor, Thermostat for cooling and heating for cooling and heating Foamed polystrene Foamed polystrene Resin Net(washable) Resin Net(washable) 16(5/8) 16(5/8) 10.8(23.8) 10.8(23.8) 12.9(28.4) 12.9(28.4) 32/30/28 34/32/28 1, 220 ~ 240, 50 1, 220 ~ 240, 50 1, 220, 60 1, 220, 60 CVVSB 1.0 ~ 1.5 2C CVVSB 1.0 ~ 1.5 2C Note: 1. Capacities are based on the following conditions: Cooling: Indoor Temperature 27 C(80.6 F) DB/19 C(66.2 F) WB utdoor Temperature 35 C(95 F) DB/24 C(75.2 F) WB Heating: Indoor Temperature 20 C(68 F) DB/15 C(59 F) WB utdoor Temperature 7 C(44.6 F) DB/6 C(42.8 F) WB Piping Length Interconnecting Piping Length 7.5m Level Difference of Zero 2. Wiring cable size must comply with the applicable local and national code. 3. The specification may be subject to change without prior notice for purpose of improvement. Conversion Formula kw = Btu/h x 0.0002931 cfm = CMM x 35.3 nly for training and service purposes 2 LGE Internal Use nly

Type Model Unit kw Cooling Capacity kcal/h Btu/h kw Heating Capacity kcal/h Btu/h Dimensions mm Body (W D H) inch Rows x Columns x FPI Coil Face Area m 2 (ft 2 ) Type Motor utput x Number W Running Current A Fan CMM Air Flow Rate(H) CFM Drive Motor type Temperature Control Sound Absorbing Thermal Insulation Material Air Filter Safety Device Liquid Side Pipe Gas Side Connections Drain(ID) Net Weight Gross Weight Noise Level(Sound Press, 1m, H/M/L) Power Supply Refrigerant Control Power cable Transmission Cable kg(lbs) kg(lbs) db(a)+1 Ø, V, Hz mm 2 x No. mm 2 x No. * Model name(art Cool Type Panel Color) R:Mirror, W:White, V:Silver Art Cool ARNU12GSB*4 ARNU15GSB*4 3.6 4.5 3 100 3 900 12 300 15 400 4.0 5.0 3 400 4 300 13 600 17 100 895x285x205 895x285x205 351/4x117/32x81/8 351/4x117/32x81/8 2 16 23 2 16 23 0.21(2.26) 0.21(2.26) Cross Flow Fan Cross Flow Fan 20 1 20 1 0.16 0.16 9.5/8.2/6.5 10.5/9.0/7.0 335/289/229 371/318/247 Microprocessor, Microprocessor, Thermostat for cooling and heating Thermostat for cooling and heating Foamed polystrene Foamed polystrene Resin Net(washable) Resin Net(washable) 16(5/8) 16(5/8) 10.8(23.8) 10.8(23.8) 12.9(28.4) 12.9(28.4) 37/34/30 40/36/32 1, 220 ~ 240, 50 1, 220 ~ 240, 50 1, 220, 60 1, 220, 60 CVVSB 1.0 ~ 1.5 2C CVVSB 1.0 ~ 1.5 2C Note: 1. Capacities are based on the following conditions: Cooling: Indoor Temperature 27 C(80.6 F) DB/19 C(66.2 F) WB utdoor Temperature 35 C(95 F) DB/24 C(75.2 F) WB Heating: Indoor Temperature 20 C(68 F) DB/15 C(59 F) WB utdoor Temperature 7 C(44.6 F) DB/6 C(42.8 F) WB Piping Length Interconnecting Piping Length 7.5m Level Difference of Zero 2. Wiring cable size must comply with the applicable local and national code. 3. The specification may be subject to change without prior notice for purpose of improvement. Conversion Formula kw = Btu/h x 0.0002931 cfm = CMM x 35.3 nly for training and service purposes 3 LGE Internal Use nly

1.Specification (SC chassis) Indoor Type Model Unit kw Cooling Capacity kcal/h Btu/h kw Heating Capacity kcal/h Btu/h Dimensions mm Body (W D H) inch Rows x Columns x FPI Coil Face Area m 2 (ft 2 ) Type Motor utput x Number W Running Current A Fan CMM Air Flow Rate(H) CFM Drive Motor type Temperature Control Sound Absorbing Thermal Insulation Material Air Filter Safety Device Liquid Side Pipe Gas Side Connections Drain(ID) Net Weight Gross Weight Noise Level(Sound Press, 1m, H/M/L) Power Supply Refrigerant Control Power cable Transmission Cable kg(lbs) kg(lbs) db(a)+1 Ø, V, Hz mm 2 No. mm 2 No. * Model name(art Cool Type Panel Color) R:Mirror, W:White, V:Silver Art Cool ARNU18GSC*4 ARNU24GSC*4 5.6 7.1 4 800 6 100 19 100 24 200 6.3 8.0 5 400 6 900 21 500 27 300 1030x325x245 1030x325x245 409/16x1225/32x921/32 409/16x1225/32x921/32 2 18 22 + 1 4 21 2 18 22 + 1 4 21 0.28(3.01) 0.28(3.01) Cross Flow Fan Cross Flow Fan 76 1 76 1 0.29 0.29 12.5/12.0/11.3 14.0/12.7/11.5 442/424/399 495/448/406 Microprocessor, Microprocessor, Thermostat for cooling and heating Thermostat for cooling and heating Foamed polystrene Foamed polystrene Resin Net(washable) Resin Net(washable) Ø9.52(3/8) Ø15.88(5/8) 16(5/8) 16(5/8) 15.4(34.0) 15.4(34.0) 17.9(39.5) 17.9(39.5) 38/35/33 43/39/35 1, 220 ~ 240, 50 1, 220 ~ 240, 50 1, 220, 60 1, 220, 60 CVVSB 1.0 ~ 1.5 2C CVVSB 1.0 ~ 1.5 2C Note: 1. Capacities are based on the following conditions: Cooling: Indoor Temperature 27 C(80.6 F) DB/19 C(66.2 F) WB utdoor Temperature 35 C(95 F) DB/24 C(75.2 F) WB Heating: Indoor Temperature 20 C(68 F) DB/15 C(59 F) WB utdoor Temperature 7 C(44.6 F) DB/6 C(42.8 F) WB Piping Length Interconnecting Piping Length 7.5m Level Difference of Zero 2. Wiring cable size must comply with the applicable local and national code. 3. The specification may be subject to change without prior notice for purpose of improvement. Conversion Formula kw = Btu/h x 0.0002931 cfm = CMM x 35.3 nly for training and service purposes 4 LGE Internal Use nly

2. List of Functions Category Air flow Air purifying Installation Reliability Convenience Individual control Special function kit Function ARNU05GSB*4, ARNU07GSB*4, ARNU09GSB*4, ARNU12GSB*4 ARNU15GSB*4, ARNU18GSC*4, ARNU24GSC*4 Air supply outlet 1 Airflow direction control(left & right) Manual Airflow direction control(up & down) Auto Auto swing(left & right) Auto swing(up & down) Auto Airflow steps(fan/cool/heat) 3/4/3 Chaos swing X Chaos wind(auto wind) Jet cool(power wind) Swirl wind Deodorizing filter Plasma air purifier Prefilter(washable / antifungus) Drain pump E.S.P. control Electric heater(operation) High ceiling operation Hot start Self diagnosis Soft dry operation Auto changeover (Heat recovery) Auto cleaning Auto operation(artificial intelligence) (Heat pump or Cooling only) Auto restart operation Child lock Forced operation Group control Sleep mode Timer(on/off) Timer(weekly) Two thermistor control Wide wired remote controller PQRCVSL0/PQRCVSL0QW Deluxe wired remote controller X Simple wired remote controller PQRCVCL0Q(W) Wired remote controller(for hotel use) PQRCHCA0Q(W) Wireless LCD remote control PQWRHQ0FDB Zone control CTIE Electro thermostat Remote temperature sensor Group control wire PZCWRCG3 Dry contact PQDSA(1)/PQDSB(1)/PQDSBC/PQDSBNGCM1/PQDSBCGCD0 : Applied X : Not applied : No relation ption : Model name & price are different according to options, and assembled in factory with main unit. Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. nly for training and service purposes 5 LGE Internal Use nly

3. Piping Diagrams SB/SC Chassis Cooling Heating Heat Exchange Th3 Th2 Filter Filter Cross flow Fan Indoor Unit Th1 Refrigerant pipe connection port diameter Model Gas [unit: ] Liquid ARNU05GSB*4 ARNU07GSB*4 ARNU09GSB*4 ARNU12GSB*4 ARNU15GSB*4 ARNU18GSC*4 ARNU24GSC*4 Ø15.88(5/8) Ø9.52(3/8) Loc Description PCB Connector (Color) Th1 Th2 Thermistor for suction air temperature Thermistor for evaporator inlet temperature CNTH1 (White) Th3 Thermistor for evaporator outlet temperature CNTH2 (Red) nly for training and service purposes 6 LGE Internal Use nly

4. Wiring Diagrams SB/SC Chassis Main PCB CNPWER CNMTR CN CNUD CNDISP2 CNHVB CNDISP1 CN12V CNCC CNPTIN CN485 CNREM CNTH2 CNTH1 nly for training and service purposes 7 LGE Internal Use nly

5. DIP Switch Setting 1. Indoor Unit SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 Function Description Setting ff Setting n Default Communication N/A (Default) ff Cycle N/A (Default) ff Group Control Selection of Master or Slave Master Slave ff Dry Contact Mode Selection of Dry Contact Wired/Wireless remote Mode controller Selection of Manual or Auto Auto ff operation Mode Installation Heater linkage Ventilator linkage Vane selection (Console) Region selection Etc. Fan continuous operation N/A Selection of Ventilator linkage Selection of up/down side Vane Selection tropical region Spare Continuous operation Removall Linkage Removal Up side + Down side Vane General model Working Up side Vane nly Tropical model ff ff ff ff For Multi V Models, DIP switch 1, 2, 6, 8 must be set FF. 2. utdoor Unit In case that the products meet specific conditions, Auto addressing function can start automatically with the improved speed by turning the DIP switch #3 of the outdoor unit and resetting the power. * Specific conditions: All names of the indoor units are ARNU****4. The serial number of Multi V super IV (outdoor units) is after ctober 2013. DIP switch 7 segment nly for training and service purposes 8 LGE Internal Use nly

6. Exploded View SB Chassis (Art Cool) 159830A 135316 152313 159830B W6631C 268711J 135500B 268711H 152302 131410 135313 149303 733010 354210 342800 149304 135500A 552209 135080 146811B 352150 W51620B W51620A 359011 346810 266090 263230C 268711B 135500C 147582A 135311 145200 147582B 147581 W50400 35211B 749740 249951 263230A W6640A 268711D LC. SVC No. Description PCB Connector (Color) Th1 263230A Thermistor for room air temperature Thermistor for pipe in temperature CNTH1 (White) Th2 263230C Thermistor for pipe out temperature CNTH2 (Red) Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer s request. Please check the correct parts in View RPL(Replacement Part List) on GCSC. (GCSC Website http://www.lge.com) nly for training and service purposes 9 LGE Internal Use nly

SC Chassis (Art Cool) 159830A 135316 152301 152313 268711J 268711H 159830B 135511 135313 W6631C 131410 149303 733010 359011 342800 135500C 149304 552209 135090 146811B 352150 354210 W51620B W51620A 346810 135500A 263230C 266090 268711B 147582A 145200A 147581 145200B 147582B W50400 35211B 135500B 249951 W6640A 263230A 268711D 135311 LC. SVC No. Description PCB Connector (Color) Th1 263230A Thermistor for room air temperature Thermistor for pipe in temperature CNTH1 (White) Th2 263230C Thermistor for pipe out temperature CNTH2 (Red) Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer s request. Please check the correct parts in View RPL(Replacement Part List) on GCSC. (GCSC Website http://www.lge.com) nly for training and service purposes 10 LGE Internal Use nly

7. Selfdiagnosis function Error Indicator This function indicates types of failure in selfdiagnosis and occurrence of failure for air condition. Error mark is displayed on display window of indoor units and wired remote controller, and 7segment LED of outdoor unit control board as shown in the table. If more than two troubles occur simultaneously, lower number of error code is first displayed. After error occurrence, if error is released, error LED is also released simultaneously. Error Display 1st,2nd,3rd LED of 7segment indicates error number, 4th LED indicates unit number. Indicates unit number. (* = 1:Master, 2 : Slave 1, 3 : Slave 2) Ex) 211 : No.21 error of master unit (repetition) 213 : No.21 error of slave2 1051 : No.105 error of master unit h Refer to the DXVenitilation manual for DXVenitilation error code Error Compressor Unit(1:Master, 2:Slave 1, 3:Slave 2) Error number Display Title Cause of Error 0 1 Air temperature sensor of indoor unit Air temperature sensor of indoor unit is open or short 0 2 Inlet pipe temperature sensor of indoor unit Inlet pipe temperature sensor of indoor unit is open or short 0 3 Communication error : wired remote controller indoor unit Failing to receive wired remote controller signal in indoor unit PCB 0 4 Drain pump Malfunction of drain pump Indoor unit related error 0 5 Communication error : Indoor communication PCB indoor unit Indoor unit PCB did not receive signal from indoor communication PCB for over 3 minutes continuously 0 6 utlet pipe temperature sensor of indoor unit utlet pipe temperature sensor of indoor unit is open or short 0 9 Indoor EEPRM Error 1 0 Poor fan motor operation In case when the serial number marked on EEPRM of Indoor unit is 0 or FFFFFF Disconnecting the fan motor connector / Failure of indoor fan motor lock 2 3 0 Refrigerant leakage sensing error Refrigerant leakage sensing error and sensor defect error 2 3 7 2 3 8 Communication defect in indoor communication PCB outdoor communication PCB Communication error in outdoor communication PCB outdoor unit Indoor communication PCB did not receive signal from outdoor communication PCB for over 3 minutes continuously utdoor communication PCB did not receive communication signal from outdoor unit for over 3 minutes continuously nly for training and service purposes 11 LGE Internal Use nly

P/N : MFL67372005 February, 2015