CrownFire Foam Systems

Similar documents
SECURITY BLANKET Foam Fire Protection Products

The metering orifice is sized according to the type and percentage of concentrate used and is also secured with a stainless steel retaining ring)

Foam Products ENGLISH

JET-X HIGH-EXPANSION FOAM GENERATORS Data/Specifications

Foam Systems U.S. Quick Reference Guide

ANSUL. Twin-Agent Fire Fighting/Securing Systems Specifications. Models 450/50-B, 450/100-B, 900/100-B INDEX SPECIFICATIONS

TECHNICAL DATA OBSOLETE

Twin-Agent Fire Fighting/Securing Systems Specifications

Transforming Challenges with Expertise. Total Protection. from concept to commissioning

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Protective & Marine Coatings Europe, Middle East, Africa & India

MAXIMUM KNOCKDOWN ABILITY Large Dry Chemical Fire Suppression Systems

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

A.U.P.C.I ASOCIACIÓN URUGUAYA DE PROTECCION CONTRA INCENDIO AUPCI

Design & Construction Standards, Revised January

PERFORMANCE AT HAND RED LINE Hand Portable Fire Extinguishers

Module 8 v1.0. Introduction to Hydrocarbon Fire Protection

Deluge Valves. Model 68 DE\ EL. Electrically Actuated Remote-Reset Deluge Valve. Dorot Fire Protection Division. Certification & compliance by design

FOAM CHAMBER MODEL - FCA & FCA-S TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100. Stainless Steel Construction

FAIRBANKS NIJHUIS FIRE PROTECTION. FIRE PUMP SETS & PUMP PACKAGES

RESEARCH AND TECHNOLOGY BUILDING RENOVATION 05/18/09 SECTION REFRIGERANT PIPING AND SPECIALITIES

SECTION ROTARY-SCREW WATER CHILLERS

FM 517 San Leon, TX Toll Free: Office: (281) Fax: (281)

SPECIAL HAZARDS THE MOST ADVANCED TECHNOLOGY FOR PROTECTING

Fire Fighting Foam and Foam Hardware

Extinguishers. Commercial Industrial High rise buildings

The development Of the new CEN standard For fire fighting foam systems EN13565 Part 2

SECTION PLUMBING EQUIPMENT

A. Section includes wet-pipe sprinkler system, system design, installation, and certification.

Tradition & Technology

FAIRBANKS NIJHUIS FIRE PROTECTION. FIRE PUMP SETS & PUMP PACKAGES

PORTABLE PERFORMANCE ANSUL Stored Pressure Fire Extinguishers

TWO TIMES THE FIGHT Twin-Agent Fire Suppression Systems

Design and Construction Standards SECTION PLUMBING EQUIPMENT

II Brazilian Sprinkler Conference October 27-28, 2016

WILLIAM HICKS. MSc, CFEI, CFPS, IAAI-CFI, MIFireE, EFO, CFOD, F-IAFI. Associate Professor Eastern Kentucky University

MODULE 2. Water-Based Suppression System Basics

EXPLOSION PROTECTION SPECIALISTS. Experts in Equipment for Explosive Atmospheres TOTAL SUPPLY MEASURE DETECT METER POWER LIGHT HEAT

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

Technical Article. High Expansion Foam Systems. Martin Workman Viking Product Manager. September,

Port of St Helens SIA Aircraft Hanger Scappoose, OR

Technical Article. Foam Systems - Low Expansion, Medium Expansion, High Expansion. Martin Workman, Product Manager Special Hazards Division

Flow Control for Fire Protection

First Line of Safety: Farris Engineering

2007 Fire Equipment Product Catalog

Firefighting Group Water Systems. 1. Spray Nozzle 2. Fire Hose Box and Fire Hose Box 3. Barrel Fire Hydrant 4. Water Monitor

HYDRONIC SPECIALTIES TACO AC(F)-PAX 05/15/2008

Our Mission. About Us. To create awareness of the essentiality attached to a firefighting system, as an important requisite in everyday life and loss

standard in firefighting foam technology worldwide

Foam Products. Quick Reference Guide EMEA. Trusted above all.

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY

A HISTORICAL REVIEW OF FLUORINATED FOAM FIREFIGHTING AGENTS, PERFORMANCE REQUIREMENTS/ ENVIRONMENTAL SAFEGUARDS REVIEW

MACH N-407 Heat Pump Air-Cooled Chiller

Ronald Sigmond 26 Oct 2016 FLAME MONITORING, GAS HANDLING SYSTEMS AND BURNERS

SECTION REFRIGERATION EQUIPMENT. A. Section Includes: Refrigeration equipment for insulated cold storage rooms including necessary accessories.

FOAM CHAMBER MODEL - FCA & FCA-S TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100. Stainless Steel Construction

Model MBEC-14. Extended Coverage Ordinary & Extra Hazard Horizontal Sidewall Sprinklers for Metal Building Applications. Model MBEC-14 (SIN R6932)

D. Reference Standards (Utilize latest editions available):

Refrigeration Plant Information. We Speak Hockey 365

Packaged Steam Fired Water Heater

ELECTRICAL HEAT EXCHANGER FOR PROCESS INDUSTRY

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

PLUMBING HEATING GAS INDUSTRIAL ACTUATION HYDRONICS COMMITMENT TO QUALITY SPECIFICATIONS

Nuclear Electric Heating

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION

FAN SEPARATOR. Fan / Separator H2SO4 (Sulfuric Acid) is Designed to Remove Fume and Other Contaminants from the Air Stream.

HIGH-EXPANSION FOAM GENERATORS

Exploration and extraction can be on land or on offshore platforms. Once extracted, ground transportation is done by means of oil or gas pipelines,

A. Air-conditioning and Refrigeration Institute (ARI) - Standard 550/590, latest edition, and ARI certification program.

SECTION WET-PIPE SPRINKLER SYSTEMS EASY RISER CHECK VALVE

A DIVISION OF HOSE & TUBING CATALOG 2017

2. Welding Materials and Procedures shall conform to the ASME Code.

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Standard Spray concealed horizontal sidewall sprinkler VK481

ENERGY, OIL & GAS. astsensors.com macrosensors.com. Transducer & Transmitter Capabilities. Your sensor business partner...

FIRE SUPPRESSION SYSTEM

mirage standard response concealed pendent sprinkler vk492 (K5.6)

MSC Guidelines for Automatic Sprinkler Systems

AIRCRAFT RESCUE AND FIREFIGHTING

SECTION SPRINKLER SYSTEMS

SINGLE STAGE MULTI STAGE NANO MICRO

HORIZON STANDARD RESPONSE FLUSH PENDENT SPRINKLER VK400 TECHNICAL DATA

SECTION WATER BASED FIRE SUPPRESSION SYSTEMS

The Most Versatile Flame Detectors in the World. Optical Flame Detection Solutions

SECTION (15530) - REFRIGERANT PIPING

Global innovation in fire fighting

WATER POWERED OSCILLATING MONITOR

MAC N-407 Air-Cooled Chiller

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

FIXED PROTECTION FOR OIL AND CHEMICAL PLANTS

First Revision No. 15-NFPA [ Chapter 2 ]

TECHNICAL SERVICES DIVISION

2012 International Fire Code Errata (Portions of text and tables not shown are unaffected by the errata)

Aircraft Hangars DESCRIPTION. A single fire area not larger than 40,000 sq. ft. (3,716 sq. m) per hangar construction type as defined by NFPA 409

TECHNICAL DATA 3% AR-AFFF

Gas Station & C Store SECTION CWM Job No

Transcription:

CrownFire Foam Systems

CrownFire offers complete systems and designs to meet NFPA, UL and FM standards... Foam Systems Applications Foam equipment and systems from CrownFire are used around the world for applications in offshore, petrochemical, power and energy, transportation and aircraft hangars and airports. With a complete range of hardware and foam concentrates available, CrownFire offers complete systems and designs to meet NFPA, UL and FM standards: Aircraft Hangars Ship Holds, Engine Rooms, & Pump Rooms Gas Compressor Stations Engine Test Cells Transformer Rooms Tire Warehouses Tire Production Facilities Flammable Liquid Storage Hazardous Waste Storage Chemical Storage Rooms Cogeneration Plants Mines Out Of Door Use (Lower Expansions) Tank Dyke Areas Refinery Process Areas Toxic Spill Protection (Ammonia, Chlorine, Lng) Made in Canada

Self Contained Foam System Foam Systems Self Container CrownFire has been producing self-contained since 1988. Our systems are supplier complete, with a large water storage tank, a foam concentrate tank, electric pump, foam proportioner and PLC controller, our systems give maximum performance and coverage of your critical assets. Our Self contained Hi-Expansion foam systems are ideal for locations where water supply is unavailable. Explosion-Proof systems are also a standard offering for our Self- Contained Foam System. Foam Generators - High Expansion CrownFire brand Self-aspirating Foam Generators are meticulously designed with just the right shape, mesh screensize, and perforation frequency to efficiently combine water, foam solution, and air. With exceptionally high expansion ratios, these rugged units are prized as fire fighting measures, especially in remote areas and where access to water is limited. Because they are self-aspirating, these units deliver a highly accurate mix of solution, water, and air without the large pressure losses associated with in-line inductors. This reduces the required pump duty and saves space.

Bladder Tank Systems CrownFire foam bladder tank systems provide accurate, dependable, and costeffective foam fire protection for a variety of flammable/combustible hazard areas, with no external power other than water pressure. Water is applied to the outside surface of the bladder, displacing foam concentrate inside the bladder, which then is injected into the water stream. CrownFire Bladder Tanks are one component in a balanced pressure foam proportioning system. The systems do not require external power, other than the water pressure to ensure correct operation. The vertical and horizontal bladder tanks are designed and constructed in accordance with the latest revisions to ASME code, Section VIII for unfired pressure vessels with a working pressure of 175 psi and tested to 1.3 times this pressure. Features UL Listed Bladder is manufactured of a vinyl based polymer, or a polyester reinforced copolymer. The bladder material shall have an ASTM D-412 Tensile Strength of at least 3000 psi and an ASTM D-624 Graves Tear Strength of at l east 420 lbs./in. Tanks are supplied with permanently mounted brass trim valves with Teflon seats. All valves are labeled showing normal working position and function. Lifting lugs are permanently welded to the tank with eyes of approximately 2 diameter. Both the vertical and horizontal tanks contain a perforated PVC center tube that assures maximum agent discharge. All tanks are approximately 10% oversized to allow for any thermal expansion of the foam concentrate. All tanks are supplied with a label, which identifies the type of foam concentrate the system is designed for, the percentage ratio and the tank size. Tanks are painted red enamel Options Coal tar epoxy for coating the interior shell of the tank (for use in salt-water environment) Sight Glass Proportioner prepiped onto tank assembly Red epoxy finish Custom fabrication of specialty materials, dimensions and capacities Actuated valves for water/concentrate Stainless steel or brass trim Insulation and heat tracing packages

CrownFire manufacturer and supplier of complete fire protection systems and detection systems, on a global basis for today s complex projects. Supplying high quality, cost effective fire solutions to meet international regulatory approvals, for industrial, marine and offshore projects...this is what CrownFire does.