Multi Zone Air Conditioner SVC MANUAL (Exploded View)

Similar documents
Multi Zone Air Conditioner SVC MANUAL (Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

(60Hz/R410A) 6CIM0-02B (Replace: 6CIM0-02A)

Wall Mounted Air Conditioner SVC MANUAL(Exploded View)

Hydro Kit (For Medium Temperature) SVC MANUAL(Exploded View)

Air Conditioner SVC MANUAL(Exploded View)

LG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static)

Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

SVC Manual(Exploded View)

Single Zone Air Conditioner SVC MANUAL (Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

SVC Manual(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Single Zone Air Conditioner SVC MANUAL(General)

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F)

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01J (Replace: 5BPM0-01H)

Ductless Split Systems Wall-mounted, Multizone Heat Pump

duct-free air conditioning systems Art cool inverter flex multi-split

Ductless Split Systems Ceiling Cassette Heat Pumps

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

Ductless Split Systems Concealed Duct Heat Pumps

AUS-DU112. New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 2766 PH : FAX :

ENGiNEERiNG AND SPECiFiCATioNS GuiDE

ENGiNEERiNG AND SPECiFiCATiONS GuiDE

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

CU-B24DBE5 CS-F28DTE5 CU-B28DBE5 CS-F28DTE5 CU-B28DBE8 CS-F34DTE5 CU-B34DBE5 CS-F34DTE5 CU- B34DBE8 CS-F43DTE5 CU-B43DBE8 CS-F50DTE5 CU-B50DBE8,

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Ductless Split Systems. J Series. The Next Generation of Ductless Split Systems

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

Ceiling Cassette Type Single-Zone Air Conditioning

(Non-Inverter & Inverter) R410A

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

Service Manual. Inverter Pair Floor / Ceiling Suspended Dual Type BA-Series. SiBE05-722_C

AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-02A(5BPU0-01A)

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

Air Conditioner CONTENTS

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-03A(Replace:5BPU0-02A)

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

SINGLE-ZONE CEILING-CONCEALED DUCTED SYSTEM ENGINEERING MANUAL

A single answer for multiple zones.

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

Kühl J Series DUCTLESS ROOM AIR CONDITIONERS THE EXPERTS IN ROOM AIR CONDITIONING. Wall-mounted Ceiling Cassette The Insider Concealed Ducted

Just feel well. 2017/2018 Air conditioning

SiBE04-808_C. Service Manual. Inverter Pair Wall Mounted Type G-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

Samsung 360 Cassette, Single Zone, Split System

Multi Air Conditioner Indoor Unit SVC MANUAL(General)

Heat Pump Air Conditioning Systems

DESIGN & TECHNICAL MANUAL

A single answer for multiple zones.

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

J SERIES DUCTLESS SPLIT SYSTEMS

SiBE041010EA. Service Manual. Inverter Pair Wall Mounted Type J-Series. [Applied Models] Inverter Pair : Heat Pump

Room Air Conditioner Service and Parts Manual

Highly Efficient,Powerful Heating and Cooling.

Up to SEER 26.1 Wall Mount Heat Pump

Geniuses at work. Residential Mini Splits

Single-Zone Four-Way Ceiling-Cassette System Engineering Manual

INDOOR UNIT PRODUCT OVERVIEW

DESIGN & TECHNICAL MANUAL

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

LV Series. SEER 15+ Concealed Built in Heat Pump

Single "A" Air Conditioner SVC MANUAL(General)

DAIKIN FBQ DUCTED SERIES HEATING & COOLING SYSTEMS. DC DUCT-CONCEALED Up to 17.5 SEER / Up to 10.6 HSPF Up to 13.0 EER

DESIGN & TECHNICAL MANUAL

DUCTLESS ROOM AIR CONDITIONERS

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Residential and Light Commercial Ductless Systems Catalog

Breeze A revolution in room cooling.

Easy to service. Up to 9 indoor units can be connected

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

DUCTED AIR CONDITIONER RANGE YOUR COMFORT ZONE.

NEW DAIKIN FTQ SERIES HEATING AND COOLING SYSTEMS. MULTI-POSITIONAL AIR HANDLER Up to 16 SEER / Up to 10.4 HSPF / Up to 12.5 EER

Wall Mounted Split Systems

FTQ SERIES DUCTED HEAT PUMP SYSTEMS. INDOOR AND OUTDOOR UNITS Up to 20 SEER / Up to 12 HSPF / Up to 14.5 EER INVERTER, VARIABLE SPEED COMPRESSOR

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

FBQ. DC Duct Heat Pump or Cooling Only

DUCTLESS SPLIT SYSTEMS

Room Air Conditioner CONTENTS CS-E9BKP CU-E9BKP5 CS-E12BKP CU-E12BKP5. Order No: MAC C2

2017 LINE UP MINI SPLITS CATALOG

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Midea R410A Tropical ClimaCreator Series Rooftop Package 220V 3Ph 60Hz Technical Manual

SiUS181631EA. Service Manual. Multi-Split Type Air Conditioners RMXS-L Series. [Applied Models] Inverter Multi : Heat Pump

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Transcription:

Multi Zone Air Conditioner SVC MANUAL (Exploded View) CAUTIN Before Servicing the unit, read the safety precautions in General SVC manual. nly for authorized service personnel. MDEL: MD12Y3JM 960-920-06

1. Specification Indoor unit type Model Ceiling Concealed Duct - Low Static MD12Y3JM Power Supply Ø / V / Hz 1/ 208~230/ 60 Capacity(*) Btu/h class 12,000 Current Running Current A 0.25 Fan Motor Type BLDC Fan Type Sirocco Fan Motor utput(w) x No. of Unit 5 x 1, 19 x 1 Air Flow Rate CMM 9.5 / 8.5 / 7.5 (H / M / L) CFM 335 / 300 / 265 External Static Pressure mmaq 4 Capacitor μf / Vac - Drive Direct Drive Coil Row x Column x FPI 2R x 12C x 21 Dimensions Body mm(inch) 820 x 190 x 575(32 9/32x7 1/2x 22 21/32) (W x H x D) Decorative Panel mm(inch) - Net Weight Body kg (lbs) 20.5(45.2) Decorative Panel kg (lbs) - Air Filter Long life filter Sound Level (H / M / L) db(a)+3 33/ 31/26 Piping Liquid mm (inch) 6.35 (1/4) Connections Gas mm (inch) 9.52 (3/8) Drain(D/ID) mm(inch) 32/25(1.26/0.984) Dehumidification Rate l/h 1.2 Safety Devices Fuse, thermal protector for fan motor Temperature Sensor Thermistor Refrigerant R410A Refrigerant Control EEV(in utdoor unit) Transmission Interunit Cable No. x AWG 4 x 18 (Including Earth) Note: 1. Capacities are based on the following conditions: Cooling: - Indoor Temperature 26.7 C(80 F) DB/19.4 C(67 F) - utdoor Temperature 35 C(95 F) DB/23.9 C(75 F) Heating: - Indoor Temperature 21.1 C(70 F) DB/15.6 C(60 F) WB - utdoor Temperature 8.3 C(47 F) DB/6.1 C(43 F) WB Piping Length - Interconnecting Piping Length 7.5m(24.6 ft.) - Level Difference of Zero 2. Wiring cable size must comply with the applicable local and national code. 3. The specification may be subject to change without prior notice for purpose of improvement. 4. For more Capacity(*),refer to the combination table Conversion Formula kw = Btu/h class 0.0002931 cfm = CMM x 35.3-2 -

2. Function Table Air flow Category Function MD12Y3JM Air purifying Installation Reliability Convenience Individual control CAC network function Air supply outlet 1 Airflow direction control(left & right) - Airflow direction control(up & down) - Auto swing(left & right) - Auto swing(up & down) - Airflow steps(fan / cool / heat) 03.3.3 Chaos swing - Chaos wind(auto wind) Jet cool(power wind) Swirl wind Deodorizing filter Plasma air purifier Prefilter(washable / anti-fungus) Drain pump E.S.P. control Electric heater(operation) High ceiling operation - Hot start Self-diagnosis Soft dry operation Auto changeover Auto cleaning Auto operation(artificial intelligence) Auto restart operation Child lock Energy-Saving Cooling Mode Forced operation Group control Sleep mode Timer(on/off) Timer(weekly) Two thermistor control Wide wired remote controller DWC1 Deluxe wired remote controller - Simple wired remote controller Simple wired remote controller(for hotel use) Wireless remote controller(simple) Wireless LCD remote control Wireless LCD remote control(ez) General central controller (Non LGAP) Dry contact Central control(lgap) PDI(power distribution indicator) PI 485 CTIE Zone control Special function kit thers Thermistor - Note : : Applied, : Not applied, - : No relation * ption : Model name & price are different according to options, and assembled in factory with main unit. * Accessory : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. - 3 -

3. Piping Diagrams Heating Heat Exchanger Gas pipe connection port Flare connection Cooling M - - 3 - - 1 Sirocco Fan - - 2 Liquid pipe connection port Flare connection LC. Description PCB Connector Th1 Thermistor for suction air temperature CN_RM Th2 Thermistor for evaporator inlet temperature CN_PIPE Th3 Thermistor for evaporator outlet temperature CN_PIPEUT - 4 -

4. Wiring Diagrams CN_REM CN_PIPE/IN CN_PIPE/UT CN_RM CN_D/PUMP CN_PWER CN_CC CN_DISPLAY CN_PTIN CN_FLAT CN_MTR1 CN_MTR2-5 -

5. Exploded View - 6 -

Model: MD12Y3JM Loc No. Description Friedrich Part # W4811 Bracket Assembly 67600702 130911 Cabinet Assembly,Indoor 67600808 249951 Case Assembly,Control(Indoor) 67600903 W6640 Connector,Terminal Block 67601407 354210 Evaporator Assembly,First 67602009 359012A Fan Assembly,Blower 67602103 359012B Fan Assembly,Blower 67602104 159830 Filter Assembly,Air Cleaner 67602200 W0FZZ Fuse Assembly 67602302 352150 Hose Assembly,Drain 67602801 336600B Housing,Wrapper 67602903 336600A Housing,Wrapper 67602904 346810A Motor Assembly,DC,Indoor 67603305 346810B Motor Assembly,DC,Indoor 67603310 346810B Motor,DC 67603331 346810A Motor,DC 67603332 330871 Pan Assembly,Drain 67603702 137211 Panel Assembly,Front(Indoor) 67603800 437213 Panel Assembly,Rear(Indoor) 67603815 268711C PCB Assembly,Main 67603908 268711E PCB Assembly,ption 67603917 158591 Pump Assembly,Water 67604100 267110 Remote Controller Assembly 67604300 263230C Thermistor Assembly,NTC 67604822 263230B Thermistor Assembly,NTC 67604805 263230A Thermistor Assembly,NTC 67604809 263230A Thermistor,NTC 67604825 263230B Thermistor,NTC 67604827 352118B Tube Assembly,Menifold(Indoor) 67606004 352118A Tube Assembly,Menifold(Indoor) 67606005-7 -

Friedrich Air Conditioning Co. I 10001 Reunion Place, Suite 500 I San Antonio, T 78216 I 877.599.5665 www.friedrich.com - 8 -