LG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static)

Similar documents
Air Conditioner SVC MANUAL(Exploded View)

Wall Mounted Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Hydro Kit (For Medium Temperature) SVC MANUAL(Exploded View)

Single Zone Air Conditioner SVC MANUAL (Exploded View)

Multi Zone Air Conditioner SVC MANUAL (Exploded View)

Multi Zone Air Conditioner SVC MANUAL (Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

SVC Manual(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Air Conditioner SVC MANUAL(Exploded View)

Room Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

Multi V Air Conditioner SVC MANUAL(Exploded View)

SINGLE-ZONE CEILING-CONCEALED DUCTED SYSTEM ENGINEERING MANUAL

Multi V Air Conditioner SVC MANUAL(Exploded View)

CU-B24DBE5 CS-F28DTE5 CU-B28DBE5 CS-F28DTE5 CU-B28DBE8 CS-F34DTE5 CU-B34DBE5 CS-F34DTE5 CU- B34DBE8 CS-F43DTE5 CU-B43DBE8 CS-F50DTE5 CU-B50DBE8,

Highly Efficient,Powerful Heating and Cooling.

SVC Manual(Exploded View)

LG VRF Systems. Air Conditioning Technologies

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

SINGLE. Technical Data Book. PAC for Europe (R410A, 50Hz, HP) Model : AC***KNPDEH/EU AC***KXAD*H/EU

LG Ventilation Kit INSTALLATION MANUAL. Model: PTVK410 / PTVK420. website

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

Air Conditioner CONTENTS

Learn more about Samsung air conditioner at:

(Non-Inverter & Inverter) R410A

SINGLE Technical Data Book SINGLE Duct S for America (R410A, HP)

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

DESIGN & TECHNICAL MANUAL

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

(60Hz/R410A) 6CIM0-02B (Replace: 6CIM0-02A)

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

Models: ACC 75D/DR ACC 100D/DR. ACC - D (Draft) Ceiling Concealed Split Systems

Ductless Split Systems Concealed Duct Heat Pumps

DESIGN & TECHNICAL MANUAL

Ductless Split Systems Wall-mounted, Multizone Heat Pump

Engineering Data Book

OUTSIDE AIR UNIT ENGINEERING MANUAL

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

Indoor Dimensions units Ducted Type LG Electronics 6.2 Outdoor units Ducted Type CALOR SRL LG Electronics

Samsung 360 Cassette, Single Zone, Split System

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

16 SEER TWO-STAGE AIR CONDITIONERS

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

Air Conditioning System

AUS-DU112. New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 2766 PH : FAX :

TECHNICAL DATA & SERVICE MANUAL

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

FLOOR STANDING, CEILING SUSPENDED, AND CONVERTIBLE SURFACE MOUNTED INDOOR UNIT ENGINEERING MANUAL

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01G (Replace: 5BPM0-01F)

SPLIT TYPE ROOM AIR CONDITIONER CEILING TYPE (60Hz)

Air-to-Water Heat Pump (50Hz, R410A) 5BPM0-01J (Replace: 5BPM0-01H)

Engineering Data Book

Air Conditioning. Technical Data. Concealed ceiling unit with high ESP EEDEN FXMQ-MB

Engineering Data Book

Engineering Data Book

Product Data Split System (R-410A) Air Handler for Multi Split Inverter System 9,000 to 24,000 BTU/Hr

DESIGN & TECHNICAL MANUAL

duct-free air conditioning systems Art cool inverter flex multi-split

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air

DESIGN & TECHNICAL MANUAL

AIR-CONDITIONER SERVICE MANUAL

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

LG AIR CONDITIONERS Ducted Split System. Quiet & Comfortable with LG HVAC.

Engineering Data Book

PMFY-P-VBM-E. Ceiling cassette (1-way flow type) R410A Data G8 1. SPECIFICATIONS EXTERNAL DIMENSIONS CENTER OF GRAVITY 1-100

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

[U] Serie MHB / MHA Manual de Ingeniería

Digital Inverter 4 series 8 & 10HP

Ductless Split Systems Ceiling Cassette Heat Pumps

SUBMITTAL DATA: PCA-A24KA7 & PUZ-A24NHA7(-BS) 24,000 BTU/H CEILING-SUSPENDED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A24NHA7

13 SEER CONDENSING UNITS

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Single-Zone Four-Way Ceiling-Cassette System Engineering Manual

SUBMITTAL DATA: PEAD-A42AA7 & PUZ-A42NKA7(-BS) 42,000 BTU/H HORIZONTAL-DUCTED HEAT PUMP SYSTEM. Job Name: System Reference: Outdoor Unit: PUZ-A42NKA7

Packaged Heat Pump. 20 Ton Rooftop Units with ReliaTel TM Controls NOTICE

I storm. Circular High Speed Hand Dryer. Model N2 : I storm...,. Patent Pending. Operating Instructions and Parts Manual

CASSETTE type SPLIT TYPE AIR CONDITIONER. (60Hz) AUU18RCLX AUU24RCLX AUU36RCLX AUU42RCLX AOU18RLX AOU24RLX AOU36RLX AOU42RLX CONTENTS.

SERVICE Manual CASSETTE TYPE AIR CONDITIONER INDOOR UNIT KH026EAM KH035EAM OUTDOOR UNIT UH026EAM UH035EAM. 1. Product Specifications

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

V8MS Mode Selection Box for VRA Heat Recovery - 60HZ

SUBMITTAL DATA: PEAD-A24AA7 & PUY-A24NHA7(-BS) 24,000 BTU/H HORIZONTAL-DUCTED AIR-CONDITIONING SYSTEM. Job Name: System Reference:

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

LG Commercial Air Conditioners 2010 Enjoy Clean, Quiet, and Comfortable Air Conditioning with LG.

ROOFTOP PACKAGED AIR CONDITIONERS

Transcription:

Internal Use Only http://biz.lgservice.com LG Air Conditioner SVC MANUAL(Exploded View) Type: Ceiling Concealed Duct(Low Static) MODEL : ABNH09GL1A2 [CB09L N12 / CB09L N12A0] ABNH12GL2A2 [CB12L N22 / CB12L N22A0] ABNH18GL2A2 [CB18L N22 / CB18L N22A0] ABNH24GL3A2 [CB24L N32 / CB24L N32A0] CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel.

1. Specification Indoor Model Name ABNH09GL1A2 [CB09L N12 / CB09L N12A0] ABNH12GL2A2 [CB12L N22 / CB12L N22A0] Power Supply V / Ø / Hz 220-240 / 1 / 50 220-240 / 1 / 50 Dimensions Body W x H x D mm 700 190 700 900 190 700 W x H x D inch 27-9/16 x 7-15/32 x 27-9/16 35-7/16 x 7-15/32 x 27-9/16 Net Weight Body kg (lbs) 17.5 (38.6) 23.0 (50.7) Heat Exchanger (Row x Column x Fins per inch) x No. - (2 x 11 x 14) x 1 (2 x 11 x 18) x 1 Face Area m 2 (ft 2 ) 0.12 (1.32) 0.17 (1.81) Type - Sirocco Fan Sirocco Fan H / M / L m 3 /min 9.0 / 7.0 / 5.5 10.0 / 8.5 / 7.0 Fan Air Flow High-static Mode H / M / L ft 3 /min 318 / 247 / 194 353 / 300 / 247 Rate (Factory Set) External Static Pressure Pa (mmaq) 25.0 (2.54) 25.0 (2.54) Fan Motor Type - BLDC BLDC Output W x No. 19 x 1 19 x 1, 5 x 1 Dehumidification Rate l/h (pts/h) 1.1 (2.3) 1.2 (2.6) Sound Pressure Level H / M / L db(a) 30 / 26 / 23 31 / 28 / 27 Sound Power Level Max. db(a) 49 52 Liquid mm(inch) Ø 6.35 (1/4) Ø 6.35 (1/4) Piping Connections Gas mm(inch) Ø 9.52 (3/8) Ø 9.52 (3/8) Drain (O.D. / I.D.) mm(inch) Ø 32.0(1-1/4) / 25.0(31/32) Ø 32.0(1-1/4) / 25.0(31/32) Safety Devices - Fuse Fuse - - - Power and Communication Cable (included Earth) No. x mm 2 (AWG) 4C x 0.75 (18) 4C x 0.75 (18) Note: 1. Wiring cable size must comply with the applicable local and national code. 2. Due to our policy of innovation some specifications may be changed without notification. 3. Sound Level Values are measured at Anechoic chamber. Therefore, these values can be increased(maximum 3dB(A)) owing to ambient conditions during operation. Conversion Formula kw = Btu/h x 0.0002931 cfm = CMM x 35.3-2 -

Model Name ABNH18GL2A2 [CB18L N22 / CB18L N22A0] ABNH24GL3A2 [CB24L N32 / CB24L N32A0] Power Supply V / Ø / Hz 220-240 / 1 / 50 220-240 / 1 / 50 Dimensions Body W x H x D mm 900 190 700 1100 190 700 W x H x D inch 35-7/16 x 7-15/32 x 27-9/16 43-5/16 x 7-15/32 x 27-9/16 Net Weight Body kg (lbs) 23.0 (50.7) 27.0 (59.5) Heat Exchanger (Row x Column x Fins per inch) x No. - (2 x 11 x 18) x 1 (3 x 11 x 18) x 1 Face Area m 2 (ft 2 ) 0.17 (1.81) 0.21 (2.31) Type - Sirocco Fan Sirocco Fan H / M / L m 3 /min 15.0 / 12.5 / 10.0 20.0 / 16.0 / 12.0 Fan Air Flow High-static Mode H / M / L ft 3 /min 530 / 441 / 353 706 / 565 / 424 Rate (Factory Set) External Static Pressure Pa (mmaq) 25.0 (2.54) 25.0 (2.54) Fan Motor Type - BLDC BLDC Output W x No. 19 x 1, 5 x 1 19 x 2 Dehumidification Rate l/h (pts/h) 1.7 (3.6) 2.2 (4.7) Sound Pressure Level H / M / L db(a) 36 / 34 / 31 39 / 35 / 32 Sound Power Level Max. db(a) 54 58 Liquid mm(inch) Ø 6.35 (1/4) Ø 9.52 (3/8) Piping Connections Gas mm(inch) Ø 12.7 (1/2) Ø 15.88 (5/8) Drain (O.D. / I.D.) mm(inch) Ø 32.0(1-1/4) / 25.0(31/32) Ø 32.0(1-1/4) / 25.0(31/32) Safety Devices - Fuse Fuse - - - Power and Communication Cable (included Earth) No. x mm 2 (AWG) 4C x 0.75 (18) 4C x 0.75 (18) Note: 1. Wiring cable size must comply with the applicable local and national code. 2. Due to our policy of innovation some specifications may be changed without notification. 3. Sound Level Values are measured at Anechoic chamber. Therefore, these values can be increased(maximum 3dB(A)) owing to ambient conditions during operation. Conversion Formula kw = Btu/h x 0.0002931 cfm = CMM x 35.3-3 -

2. Piping Diagrams Model : ABNH09GL1A2 [CB09L N12 / CB09L N12A0] : Cooling : Heating Evaporator Out Sirocco Fan M Evaporator In Indoor Unit Inlet Air Description Inlet Air Evaporator In Evaporator Out PCB Connector CN-ROOM CN-PIPE/IN CN-PIPE/OUT - 4 -

Model : ABNH12GL2A2 [CB12L N22 / CB12L N22A0], ABNH18GL2A2 [CB18L N22 / CB18L N22A0] Evaporator Out : Cooling : Heating M Sirocco Fan M Evaporator In Indoor Unit Inlet Air Description Inlet Air Evaporator In Evaporator Out PCB Connector CN-ROOM CN-PIPE/IN CN-PIPE/OUT - 5 -

Model : ABNH24GL3A2 [CB24L N32 / CB24L N32A0] : Cooling : Heating Evaporator Out M Sirocco Fan M Evaporator In Indoor Unit Inlet Air Description Inlet Air Evaporator In Evaporator Out PCB Connector CN-ROOM CN-PIPE/IN CN-PIPE/OUT - 6 -

3. Wiring Diagrams L1 Chassis CN-MOTOR1 CN-ZONE CN-FLOAT CN-DISPLAY CN-CC CN-D/PUMP CN-POWER CN-ROOM CN-REMO CN-PIPE/IN CN-PIPE/OUT - 7 -

L2/L3 Chassis CN-MOTOR2 CN-MOTOR1 CN-ZONE CN-FLOAT CN-DISPLAY CN-CC CN-D/PUMP CN-POWER CN-ROOM CN-REMO CN-PIPE/IN CN-PIPE/OUT - 8 -

4. Exploded View L1 Chassis 159830 336600B W1JK 359012B W1JK 346810 354210 352118 249951 55211G 263230A THERMISTOR 1 263230B THERMISTOR 2 263230C THERMISTOR 3 268711B 268711A W6640A W6640B 336600A 359012A W4810 237200 330871 158591 437213 137211 1 263230A Air Housing color : yellow 2 263230B Eva. in Housing color : white 3 263230C Eva. out Housing color : red - 9 -

L2 Chassis 159830 336600B 346810B 346810A W1JK 354210 249951 263230A THERMISTOR 1 263230B THERMISTOR 2 263230C THERMISTOR 3 268711A 359012B 336600A W6640B W4810 352118 55211G 268711B W6640A 237200 359012A W51620 330871 158591 437213 137211 1 263230A Air Housing color : yellow 2 263230B Eva. in Housing color : white 3 263230C Eva. out Housing color : red - 10 -

L3 Chassis 159830 336600B W1JK 346810 268711A 359012B 249951 354210 263230A THERMISTOR 1 263230B THERMISTOR 2 263230C THERMISTOR 3 W6640A 268711B W6640B 237200 336600A 359012A 352118 55211G W51620 W4810 330871 158591 437213 137211 1 263230A Air Housing color : yellow 2 263230B Eva. in Housing color : white 3 263230C Eva. out Housing color : red Note) * Please ensure GCSC since the replacement parts may be changed depending upon the buyer's request. Please check the correct parts in View RPL(Replacement Part List) on GCGS. (GCGS Website http://biz.lgservice.com) - 11 -

P/NO : MFL67642602 November, 2014