Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

Similar documents
Applications. Standard Materials

WARNING WARNING. Installation Instructions for 116DEXSTC-FJ AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations.

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

EVLPF Series Compact Fluorescent

CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Enclosure 4X

*RENTAL* Class 1 Division Watt Incandescent Light - Explosion Proof - Wall Mount Volts

4' 2 Lamp Fluorescent Light Fixture - Emergency Battery Backup - T8 Bulbs - Multi-voltage - CID2

EVLED201 36W Led Luminaire. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 14.85

Installation Instructions for 116DEGEX-FJ-(R) AdaptaBeacon Fire Alarm Strobe Lights for Use in Hazardous Locations

Class 1 Division 2 Hazardous Location Stack Light - Signal Traffic Light - Multiple Lamp Colors

SIMPLIFIED LIGHTING. TRUSTED PROTECTION. CODE MASTER LED LUMINAIRES CLASS I, DIVISION 1

Class 1 Div 2 LED Pivoting Light - 2 foot 2 lamp - LED T series Style V Dimmable

Hazardous Area LED Light -Class 1 Div 2 Groups A, B, C, D and Class 2 Div 2 F,G - 4' 4 lamp

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

LMV Series W Low Profile - Medium Base

Installation Instructions for 116EXMLED Series AdaptaBeacon LED Lights for Use in Hazardous Locations. Description. Installation WARNING

N2MVF Series Compact Fluorescent

Table 500-3(d) Identification Numbers. Maximum Identification

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

120W Explosion Proof Signal Light w/ Audible Alarm - C1D1 - (2) Colored LED Lamps - 55 Horn Tones

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

UL Listed Available with Cl. I, Div. 2, Groups A, B, C, D rating

COMPACT SIZE INTRODUCTION & LOGIC

UTILITY LIGHT INTRODUCTION

48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2

Explosion Proof UV/Visible Light Fluorescent Fixture - Paint Spray Booth, Rigs - Two Circuit Lamps

Rating. Class I Div II

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

VAPORGARD Incandescent Luminaires

elevated ambient capability. in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems.

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

56W Hazardous Location LED Fixture - C1D2 - Stainless Steel - Dimmable - DALI Network

Vaporproof White LED Light - 10 Watts - Non-Metallic - Corrosion Resistant Lumens

DMV Series W For Combustible Dusts

5 yr. Vitalite Rotating Warning Light. Models 121 and 121A LIGHT DUTY VEHICULAR LIGHT

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

Industrial Horn & LED Strobe Warning System - 12V DC - Weatherproof - NEMA 4X - Class 1 Beacon

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

Explosion Proof Emergency Fluorescent Light Combination - Dimmable Ballast - C1D1-2 T8 lamps - 4'

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

Model 9001EXP Alarm. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

INSTRUCTION & SERVICE MANUAL

MODEL LP3 INSTALLATION AND SERVICE INSTRUCTIONS FOR STREAMLINE LP3 STROBE LIGHTS

WE PROTECT HAZARDOUS ENVIRONMENTS EXPLOSION-PROOF AND HAZARDOUS LOCATION VISUAL & AUDIBLE SIGNALING PRODUCTS

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

50W Explosion Proof LED Light - C1D2, C2D1 - Replacement for 150W Metal Halide - Globe/Guard

INSTRUCTION & SERVICE MANUAL

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

MERCMASTER LED SERIES

AFTER INSTALLATION DELIVER THIS MANUAL TO OWNER IMPORTANT SAFETY INSTRUCTIONS

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

Explosion Proof 70 Watt Low Profile LED Light Fixture Lumens - C1D1 Group B - Hydrogen Rated

MODELS ASHP, ASHH, ASUP, and ASUH

Champ-Pak Wall Pack Luminares

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

REDUCED PROFILE INTRODUCTION

Installation and Maintenance Manual. Model 154XST Series Strobe Light for Use in Hazardous Conditions. français...page 21 español...

MAR2 LED SERIES M A R 2 L E D. Linear LED Lighting for Hazardous Locations

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

MODELS 304GC, 304GCX, 314GC, and 314GCX

CATALOG NUMBER NAME DESCRIPTION HTL X Keeper 2 40 Watts 120v 5000K 4,000 Lm HTL X Keeper 2 40 Watts 277v 5000K 4,000 Lm 4.

Explosion Proof 160 W Class 1 & 2 Fluorescent UV Light With 4 Lamps - Class 1 Division 1

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

HID lighting for hazardous areas Champ HID floodlighting. Champ floodlights. HID floodlighting for hazardous areas

INSTRUCTION MANUAL. D1xB2XH1 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

INSTRUCTION & SERVICE MANUAL D1xS1 & D1xS2 ALARM HORNS For Use In Hazardous Locations - Gas

INSTRUCTION MANUAL. D1xB2XH2 Xenon Beacon For use in Hazardous Locations. 2) Rating & Marking Information

GRP Flameproof Combination Signal db(a) / 5 Joule Series YL6S

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

INSTRUCTION MANUAL. D2xB1XH1 & D2xB1XH2 Xenon Beacons For use in Hazardous Locations

MODELS SafeSite LED Linear, Class I Div. 1 2 & 4 Versions

OPERATING AND INSTALLATION

standards: standards:

The Signal Is Clear TM

Explosion Proof Combination Signal db (A) / 5 Joule Series YL60

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed

Contender Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

56W Hazardous Location LED Light - C1D2 - Corrosion Resistant for Marine - Dimmable - DALI Network

Brasch Hazardous Location Unit Heaters

EXH Series Explosionproof Electric Air Heaters

Introduction to Flow Switch

Explosion Proof LED String Lights - 5 Hand Lamps - Class 1 & Class 2

Yodalarm. Sounders. Pg Y03 Y04/YL4 Y05/YL5 Y08/YL8/Y08 SUPER/ YL8 SUPER V4 V6/Y06/YL6 Carillon

INSTRUCTION MANUAL (ATEX / IECEx)

Champ-Pak TM Wall Pack & Floodlight Luminaires Hazardous and Non-Hazardous

Centro-Matic Automated Lubrication Systems System Controls

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Global Series. Installation and Maintenance Instructions. Model G-STR Strobe Beacon. For Use in Hazardous Locations

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

TrueAlert Multi-Candela Notification Appliances

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

EDS Series Factory Sealed Manual Motor Starters and Contactors Explosionproof, Dust-Ignitionproof

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

V2LCHF2UNV1 Led Lumnr. Features. Material, Color, and Finish. Long Description. Manufacturer Information EATON CROUSE-HINDS SERIES GTIN

Transcription:

Code Master Factory Sealed Strobe Luminaires Lighting Lighting: Explosionproof Visual Signal Applications Code Master Explosionproof Strobe fixtures are designed to provide safe operation in the presence of hazardous gases, vapors or dusts, defined by the National Electrical Code as Class I, Groups C and D; and Class II, Groups E, F and G. For use in hazardous locations such as plants where plastics, paints, thinners and petrochemicals are manufactured. Also used in areas where audible signals cannot be heard, to warn of unsafe conditions and for other communication needs. Features Fixtures operate safely in high ambient temperatures. Minimum operating temperature is -13 F/-25 C. Available for fire alarm hearing impaired. 65 flashes per minute. Fixtures are complete with lamp. Patented wireless design. Threading of fixture unit onto mounting hood makes electrical connection. The only wiring required is attaching two wires to connection block in mounting hood. Connection block is easily wired: (a) loosen two screws, (b) make wire connections; and (c) re-position connection block. Safe, easy servicing without disconnecting any wiring. Wireless fixture unit threads off mounting hood for convenient servicing or for immediate replacement with a stand by unit. Acme double lead threads speed installation and fixture removal from mounting hood. Only half as many turns are required as for single lead threads. The threads do not stick or gall, eliminating problems often encountered with single lead threads during fixture unit removal. All threaded joints are flame-tight. Factory installed lens available in five colors: red, amber, blue, green and clear (factory installed). Factory sealed. External seals are not required. Heat- and impact-resistant globes have smooth dust-resistant exterior. Fixture is suitable for mounting globe up or globe down utilizing pendant, ceiling or wall bracket type mounts. Optional guards protect globes from damage. Standard Materials Fixture housing, mounting hoods and guards: copperfree (4/10 of 1% max.) aluminum Globes: prismatic glass Screws: Stainless steel (3) Standard Finishes Fixture housing, guards and mounting hoods: epoxy power coat finish, electrostatically applied for complete, uniform corrosion protection Certifications and Compliances UL Listed: E212210 UL Standard: 1203 UL Standard: 1638 Visual Signaling Appliances UL Standard: 1971 Visual Signaling Equipment has been investigated for fire protective signaling services to alert hearing impaired persons. This signaling equipment is intended to be used in conjunction with Listed compatible units and devices. Visual signaling equipment Listed in this category is intended to be used in the Public Operating Mode as defined in NFPA 72 Fixture (shown with optional guard) are suitable for mounting in any position including globe up or globe down utilizing pendant, ceiling or wall-bracket type mounts. 1308

Code Master Factory Sealed Strobe Luminaires Ordering Information Order using catalog numbering guide below or select catalog number from tables on following pages. Catalog Numbering Guide CS S P 75 120AC CL P Series: CS - Code Master Signal Type: S - Strobe Mounting Hood: P - Pendant B - Wall bracket C - Ceiling Voltage Current: 120 AC - 120 Vac 240 AC - 240 Vac 250 DC - 250 Vdc 2030 DC - 20-30 Vdc ➊ 24 DC - 24 Vdc ➌ Hub Size: 75 3/4 Globe: CL - Clear AM - Amber ➋ BL - Blue ➋ GR - Green ➋ RE - Red ➋ Options: P - Hearing Impaired (UL1971) (Strobe Only) G - Guard Lighting Lighting: Explosionproof Visual Signal Thermal Suitability of Code-Master Strobe Fixture Ambient Temp. F/ C Class I, Division 1 and 2 Groups C & D Class I, Division 2 Groups A & B Class II, Division 1 & 2 104/40 T6 T2B T4A 131/55 T6 T2B T4A 149/65 T6 T2A T4 Operating Temperatures T Numbers Represent the Maximum Internal Temperature for Class I, Division 2 Locations; Maximum Surface Temperature for Class I, Division 1 Locations; and Maximum Surface Temperature Under Dust Blanket for Class II, Division 1 Locations. T Number T1 350 325 T2 T2A T2B T2C T2D T3 T3A T3B T3C T4 T4A T5 T6 Temp. Range ( F) 664-842 619-662 574-617 538-572 502-536 448-500 421-446 394-419 358-392 331-356 322-329 277-320 250-275 214-248 187-212 185 Temp. Range ( C) 351-450 326-350 301-325 281-300 261-280 231-260 216-230 201-215 NOTE: The maximum operating temperature of the fixture must not exceed the ignition temperature of the gas, vapor or dust to be encountered per the National Electrical Code. 181-200 166-180 161-165 136-160 121-135 101-120 86-100 85 ➊ UL1971: Hearing-Impaired Strobe Only ➋ Not for use with UL1971 Strobe ➌ Diode Polarized (Current limiter supplied as standard). 1309

Code Master Factory Sealed Strobe Luminaires Lighting Lighting: Explosionproof Visual Signal Standard Strobes Pendant One Hub 3/4 NPT, Rigid Conduit Ceiling Four Hubs 3/4 NPT, Three Close-Up Plugs, Rigid Conduit Bracket Four Hubs 3/4 NPT, Three Close-Up Plugs, Rigid Conduit Volts Catalog Number ➊➌ 120 Vac CSSP75120ACCL 240 Vac CSSP75240ACCL 250 Vdc CSSP75250DCCL 24 Vdc CSSP7524DCCL ➋ 120 Vac CSSC75120ACCL 240 Vac CSSC75240ACCL 250 Vdc CSSC75250DCCL 24 Vdc CSSC7524DCCL ➋ 120 Vac CSSB75120ACCL 240 Vac CSSB75240ACCL 250 Vdc CSSB75250DCCL 24 Vdc CSSB7524DCCL ➋ Fixture Unit Only Less Mounting Hood 10.3 lb/4.7 kg 120 Vac CSST120ACCL 240 Vac CSST240ACCL 250 Vdc CSST250DCCL 24 Vdc CSST24PDCCL ➋ Weight Hub Size (Inches) Catalog Number Pendant Mounting Hood One Hub 3/4 NPT, Rigid Conduit 2.0 lb/9.0 kg 3/4 CAP75 Ceiling Mounting Hood Four Hubs 3/4 NPT, Three Close-Up Plugs, Rigid Conduit 4.0 lb/1.8 kg 3/4 CAC75 Bracket Mounting Hood Four Hubs 3/4 NPT, Three Close-Up Plugs, Rigid Conduit 6.0 lb/2.7 kg 3/4 CALB75 ➊ Add -G suffix for optional guard. ➋ Diode polarized (current limiter supplied as standard). ➌ Catalog numbers shown are supplied with clear lens. To order colored lens, replace last digits of catalog number CL with AM for amber; BL for blue; GR for green; and RE for red. 1310

Code Master Factory Sealed Strobe Luminaires Strobes for the Hearing Impaired Pendant One Hub 3/4 NPT, Rigid Conduit Ceiling Four Hubs 3/4 NPT, Three Close-Up Plugs, Rigid Conduit Type Mounting Volts Catalog Number UL1971: Hearing-Impaired ➊ 20-30 Vdc CSSP752030DCCLP 20-30 Vdc CSSC752030DCCLP Lighting Lighting: Explosionproof Visual Signal Fixture Unit Only Less Mounting Hood 20-30 Vdc CSSB752030DCCLP Fixture Unit Only Less Mounting Hood 10.3 lb/4.7 kg 20-30 Vdc CSST2030PDCCL Weight Hub Size (Inches) Catalog Number UL1971: Hearing-Impaired Pendant Mounting Hood One Hub 3/4 NPT, Rigid Conduit 2.0 lb/9.0 kg 3/4 CAP75-1971 Ceiling Mounting Hood Four Hubs 3/4 NPT, Three Close-Up Plugs, Rigid Conduit 4.0 lb/1.8 kg 3/4 CAC75-1971 Bracket Mounting Hood Four Hubs 3/4 NPT, Three Close-Up Plugs, Rigid Conduit 6.0 lb/2.7 kg 3/4 CALB75-1971 ➊ Only clear globes are available for UL1971 applications. 1311

Code Master Factory Sealed Strobe Luminaire Accessories Lighting Lighting: Explosionproof Visual Signal Optional Aluminum Guard Replacement Connection Block Standard For Non-Hearing-Impaired CodeMaster Fixtures Description Weight Lbs/Kg Catalog Number 1.0/0.5 CJGU-15 0.5/0.2 VPT-7 Replacement Connection Block UL1971: Hearing-Impaired For Code-Master Fixtures for the Hearing Impaired 0.5/0.2 VPT-7P Replacement Lamps Fixture Type Lamp Type Voltage Base Type Catalog Number Xenon All Octal Socket S865 Strobe 1312

Code Master Factory Sealed Strobe Luminaire Family Tree and Dimensions Pendant Ceiling Bracket One Hub Four Hubs Four Hubs Three Close-Up Plugs Three Close-Up Plugs 3/4 NPT 3/4 NPT 3/4 NPT CAP75 CAC75 CALB75 CAP75-1971 CAC75-1971 CALB75-1971 Strobe Fixture Unit With Globe 120AC CSST120ACCL 240AC CSST240ACCL 250DC CSST250DCCL 20-30DC CSST2030PDCCL ➊ 24DC CSST24PDCCL ➋ Lighting Lighting: Explosionproof Visual Signal Optional Aluminum Guard CJGU-15 Dimensions in Inches/Millimeters Pendant Ceiling Wall Bracket Hub for.75" NPT Conduit 13.53"/ 343.7 mm 3.75"/ 95.3 mm 13.15"/ 334.0 mm 4.50"/ 114.3 mm Hub for.75" NPT Conduit Four Sides 13.38"/ 339.9 mm 4.00"/ 101.6 mm 4.00"/ 101.6 mm 13.00"/ 330.2 mm 4.00"/ 101.6 mm 5.92"/ 150.4 mm 4.50"/ 114.3 mm Dia. 5.95"/ 151.3 mm 4.92"/ 125.0 mm Sq. 3.92"/ 99.6 mm 4.92"/ 125.0 mm 0.41"/ 10.4 mm Dia. Hub For 3/4 NPT 2 Wiring access 2.46"/ 62.5 mm 57.9 2.28"/ mm cover both sides. 1.23"/ 31.2 mm 3.46"/ 87.9 mm 11.5"/ 292.1 mm 13.75"/ 349.3 mm 13.88"/ 352.6 mm 12.38"/ 314.5 mm 1.79"/ 45.5 mm 13.75"/ 349.3 mm 4.25"/ 108.0 mm 7.80"/ 198.1 mm 7.80"/ 198.1 mm 7.80"/ 198.1 mm ➊ UL1971: Hearing-Impaired Strobe Only ➋ Diode polarized (current limiter supplied as standard). 1313