Polymeric Fixtures for Class I, Division 2; Wet and Marine Locations... D17 Hazlux 1 Mogul Base Hazlite M1 Medium Base

Similar documents
Explosion-proof Duct Heaters

Explosion Proof Speaker, Ringer & Speaker/Ringer

Manufacturers of Explosion Proof, Corrosion Resistant and Severe Duty HVAC/R Systems, and Pressurization Equipment.

SAFETY APPROVED FLASHLIGHTS: UNDERSTANDING THE REQUIREMENTS INTRODUCTION & OVERVIEW

Applications. Standard Materials

elevated ambient capability. in installations where moisture, dirt, dust, vibration, corrosion and rough usage are problems.

FACT SHEET Program: Lab Fire Safety

Explosion Proof Speaker, Ringer & Speaker/Ringer

Electron Microscopy Sciences

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

LMV Series W Low Profile - Medium Base

Overview of Hazardous Locations as They Relate to Solenoid Valves

DMV Series W For Combustible Dusts

Type SP87300 SAFE-T SHP9 Explosion Proof Stirring Hot Plate

TECHNICAL NOTE. Response Factors for Flame Ionization Detector Operation FLAME IONIZATION DETECTOR OPERATION BASICS

50W Explosion Proof LED Light - C1D2, C2D1 - Replacement for 150W Metal Halide - Globe/Guard

EVLPF Series Compact Fluorescent

HAZLUX INDUSTRIAL INDUCTION LIGHTING

N2MVF Series Compact Fluorescent

Explosion-Proof and Fan-Forced Unit Heaters. Our products do more in a wide range of applications. Expect More.

Explosion Proof Light Watt Metal Halide - Class 1 Div 1 & Class 2 Div 1

S T R I T T & P R I E B E I N C.

INSTALLATION, PARTS, SERVICE & MAINTENANCE MANUAL FOR EPH-FH SERIES HEATER

CEC: Class I, Division 2, Groups A, B, C, D Class II, Division 1 and 2, Groups E, F, G Class III Enclosure 4X

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-8: ELECTRICAL EQUIPMENT ENCLOSURES AND HAZARDOUS LOCATIONS

Guide for hazardous areas

ULTIMA XIR ULTIMA X 3 ULTIMA XE. ULTIMA X Series. [ State-of-the-Art Gas Monitoring]

Champ-Pak TM Wall Pack & Floodlight Luminaires Hazardous and Non-Hazardous

Hazardous area descriptions

Explosion Proof LED Light - Equivalent to Watt Metal Halide - Class 1 Division 2

Fire Alarm System Accessories

Rating. Class I Div II

E THANOL AND B IODIESEL P LANT L IGHTING S OLUTIONS

Fire Alarm System Accessories

Explosion Proof LED Strobe Light - 4Hz Flash Rate - 10 Watts - Class I, Div. I - IP67

INSTALLATION, PARTS, SERVICE & MAINTENANCE MANUAL FOR HLA SERIES HEATER

Table 500-3(d) Identification Numbers. Maximum Identification

HLA Series Hazardous Location Fan Forced Unit Heater Data Sheet

Flammable and Combustible Liquids Checklist

80W C1D2 Hazardous Location Integrated LED - Corrosion Resistant for Marine - Emergency Backup

HLA Series Hazardous Location Fan Forced Unit Heater

ESD3000 ESD200 Combustible / Toxic Gas Detector

Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications. Now cul Listed!

EVLED201 36W Led Luminaire. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 14.85

MN/DOT Specification Sign Lighting Luminaire With 150 or 250 Watt Metal Halide Lamps 11/05/09

HLA Series Hazardous Location Fan Forced Unit Heater

4' 2 Lamp Fluorescent Light Fixture - Emergency Battery Backup - T8 Bulbs - Multi-voltage - CID2

COMPACT SIZE INTRODUCTION & LOGIC

Arlington. Full Cutoff. Utility Series

LED hazardous lighting catalog

VSD AND SS DRIVING ATEX MOTORS February 2014

Flammable and Combustible Liquids: Storage and Handling

Electrical Area Classification 101 An Introduction to Area Classification the Basics IEEE Houston CED

Petrolux III. PW Series Wet Locations

HID lighting for hazardous areas Champ HID floodlighting. Champ floodlights. HID floodlighting for hazardous areas

Lighting for Hazardous & Severe Environments

C1D1 Explosion Proof 50W LED Flood Light Fixture - Paint Spray Booth Approved - Adj Surface Mount

Enhancing Safety + Productivity. Champ VMV LED Series Luminaires Leading the way in LED technology for industrial and hazardous applications

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

Code Master Factory Sealed Strobe Luminaires Explosionproof, Dust-Ignitionproof

*RENTAL* Class 1 Division Watt Incandescent Light - Explosion Proof - Wall Mount Volts

150W Explosion Proof High Bay LED Light Fixture - C1D1&2 - C2D1&2-17,500 Lumens - 60 Beam

1. GENERAL TECHNICAL INFORMATION

ESD3000IR ESD3000IR. Infrared Gas Detector

ESD500. ESD500 Combustible / Toxic Gas Detector

Champ-Pak Wall Pack Luminares

C2D1/C1D2 Explosion Proof 50 Watt LED Light Fixture - Paint Spray Booth Approved - 6,250 Lumens

Hazardous Location LED String Lights - 5 Jelly Jar Lamps - Non Metallic - Chemical Resistant - CID2

A GUIDE TO EUROPEAN (EEC) CERTIFICATION FOR ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

Installation Instructions. Tersen. Ratio Canopy 1.5

MICROpeL 75 Combustible Gas Sensor Part Number: PM

Hazardous Area LED Lighting Hazard Gard LED Luminaires. Hazard Gard EVLL LED

60W Flameproof LED Emergency Linear Fixture V AC - (2) 30W LED Lamps - ATEX/IECEx

UL Listed Available with Cl. I, Div. 2, Groups A, B, C, D rating

300W Low Profile Clean Room LED Light - LED Signal Light - C1D1 - C2D2 - ISO 14644/FS-209E Rated

Specifying Temperature Sensors for Hazardous Areas

40W Explosion Proof LED Light Fixture - C1D1, C2D1-2x2 Lay-in Troffer - ATEX/ISO Rated

Pro Series LED Lighting Champ LED floodlights. Champ Pro Series. LED floodlights for heavy industrial

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

26 Watt Explosion Proof Low Profile LED Fixture - 3,380 Lumens - Class 1 & 2 Div 1 & 2 - ATEX / IECE

50W Explosion Proof Trunnion Mount Compact LED Flood Light - C1D2, C2D1 - Paint Spray Booth Approved

Low Profile Clean Room 150W LED Light - 2x2 Lay-In Troffer C1D1 - C2D2 - ISO 14644/FS-209E

PYROS. Código: FT-PY01-I Revisión: TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white

High Mast Series HMAO HMSC

WATER BATH BM100 BM200

Tradition & Technology

Electric Explosion-Proof Heaters & Thermostats. Product Catalog

Hazardous Location LED Pivoting Light - C1D2 - Dimmable - Modbus TCP/IP Network - Meets USCG Specs

Vaporproof White LED Light - 10 Watts - Non-Metallic - Corrosion Resistant Lumens

Explosion Proof LED Light - Equivalent to Watt HID C1D2, UL Listed

Electric Explosion-Proof Heaters & Thermostats. Product Catalog

Full Cutoff. Utility Series

Working safely with flammable liquids

Explosion Proof C1D2 0-10V Dimmable LED Fixture - 4ft 2 Lamp - Emergency Ballast - Terminal Strips

Brasch Hazardous Location Unit Heaters

ATEX - ATmosphere EXplosive

Dräger PEX 3000 Flammable Gas Detection

EXH Series Explosionproof Electric Air Heaters

100W Explosion Proof Low Bay AC LED Fixture - C1D1 - C2D1 - Group B + ATEX/IECEX - IP67 Waterproof

Transcription:

General Information...................... 3 Certification Guides T-Number Table Hazardous Locations Ignition Temperatures and Group Classifications for Flammable Gases and Vapors Polymeric Fixtures for Class I, ivision 2; Wet and Marine Locations................ 17 Hazlux 1 Mogul Base Hazlite M1 Medium Base Enclosed and Gasketed Fixtures for Adverse, Wet, and Marine Locations....... 39 Hazlux 2 Mogul Base Hazlite M2 Medium Base Enclosed and Gasketed Fixtures for Class I, ivision 2; Class II; Wet and Marine Locations............................. 67 Hazlux 3 Mogul Base Hazlite M3 Medium Base Incandescent Lighting Fixtures for Class I; Class II; Wet and Marine Locations........ 105 Hazlite M4 Hazlite M5 Compact Fluorescent Lighting Fixtures for Class I; Class II; Wet and Marine Locations............................. 115 Hazlite M4 Hazlite M5 Hazlite M9 Fluorescent Lighting Fixtures Class I; Class II; Wet, Marine and Hosedown Locations............................. 135 Hazlux 6 FP and FS Hazlux 6 FA Hazlux 7 Hazlux LumaShield Explosion Proof Fixtures for Class I, ivision 1; Class II; Wet and Marine Locations............................. 159 Hazlux 5 Mogul Base Hazlite M5 Medium Base Emergency Lighting and Strobe Lights for Hazardous, Wet and Marine Locations..... 179 HazBatt H3 HazBatt M5 HazFlash M4 HazFlash M5 Wall Mount and Floodlight Fixtures for General Purpose, Wet, Marine and Hazardous Locations............................. 201 Hazlux Wall Mounts Hazlux 2 Floodlights Hazlux 3 Floodlights Hazlux 5 Floodlights Appendix I: UNIPAK Packaging and Lamps............................ 215

Hazlux General Information HAZLUX LIGHTING FIXTURES INEX FIXTURE...PAGE Hazlux 1...19 Hazlite M1...31 Hazlux 2...41 Hazlite M2...57 Hazlux 3...40, 69 Hazlite M3...96 Hazlite M4...107, 117 Hazlite M5...113, 123, 173 Hazlite M9...124 Hazlux 6...137 Hazlux LumaShield...149 Hazlux 7...155 Hazlux 5...161 HazBatt H2 and H3...181, 183 HazBatt M5...185 HazFlash M4...189, 193 Hazlux Wall Mounts...203 Hazlux Floodlights (All)...207 2 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

General Information GENERAL INFORMATION CONTENTS...PAGE Certification Guides...5 T-Number Table...9 Hazlux Hazardous Locations...11 Ignition Temperatures and Group Classifications for Flammable Gases and Vapors...12 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 3

General Information HAZLUX 1 CERTIFICATION GUIE (40 C AMBIENT) LAMP TYPE WATTS AMBIENT TEMP (eg. C) CLASS I, IVISION 2 TEMPERATURE COE Globe*/Guard & Reflector Refractor*/ Guard MARINE* NEMA 4X (Suitable for Hosedown)* WET LOCATIONS SUPPLY WIRE TEMP. RATING C HIGH PRESSURE SOIUM METAL HALIE 50 40 T3 T3 YES YES YES 90 70 40 T3 T3 YES YES YES 90 100 40 T3 T3 YES YES YES 90 150 40 T2C T2C YES YES YES 90 70 40 T3C T3C YES YES YES 90 100 40 T3 T3 YES YES YES 90 175 40 T2B T2A YES YES YES 90 MERCURY 100 40 T2B T2B YES YES YES 90 VAPOR 175 40 T2B T2B YES YES YES 90 Hazlux HAZLITE M1 CERTIFICATION GUIE LAMP TYPE AMBIENT C MARINE ORINARY CLASS I, IVISION 2 GLOBES TR REFRACTOR WITH/ WITHOUT REFLECTORS NEMA 4X (Suitable for Hosedown)* SUPPLY WIRE SUITABLE C Temp. C Temp. Code 35 Watt H.P.S. 40 Yes Yes 180 T3A Yes 75 120 Type S76 55 Yes Yes 200 T3 Yes 90 120 50 Watt H.P.S. 40 Yes Yes 215 T2 Yes 75 120 Type S68 55 Yes Yes 215 T2 Yes 90 120 70 Watt 40 Yes Yes 260 T2B Yes 75 120 H.P.S. 55 Yes Yes 260 T2B Yes 90 120 Type S62 100 Watt H.P.S. 40 No Yes 280 T2A Yes 110 120 Type S54 9 Watt Fluorescent 40 Yes Yes 160 T3C Yes 90 120 13 Watt Fluorescent 40 Yes Yes 160 T3C Yes 90 120 18 Watt Fluorescent 40 Yes Yes 160 T3C Yes 90 120 26 Watt Fluorescent 40 Yes Yes 200 T3 Yes 90 120 100 Watt M.V. 40 No Yes 280 T2A Yes 75 120 Type H38 Contact Factory VOLTS NOTE REGARING GLASS GLOBES AN REFRACTORS All Hazlux fixture assemblies shown in this Buyers Guide as UL Listed or CSA Certified for Marine applications are suitable for hosedown when fixture is off and glass has been allowed to cool. Tempered glass globes and refractors have better thermal shock resistance properties than non-tempered globes and refractors and should be considered whenever fixtures are subject to being splashed with significantly cooler liquids while illuminated (hot). Consult factory for more information. 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 5

Hazlux HAZLUX 3 CERTIFICATION GUIE (40 C AMBIENT) STANAR BALLAST HOUSING - 5-1/2'' THREA LAMP TYPE HIGH PRESSURE SOIUM MERCURY VAPOR General Information WATTS AMBIENT TEMP (eg. C) CLASS I, IVISION 2 CLASS II GROUPS A, B, C, IVISION 1 & 2 TEMPERATURE COE GROUPS UL 1598 VGT/VGL22 5-1/2 Globe, Guard & Reflector VRF22C5 12'' ia. Refractor VGT/VGL22 5-1/2 Globe, Guard & Reflector VRF22C5 12'' ia. Refractor MARINE* NEMA 4X* CHART A SUPPLY WIRE TEMP. RATING (eg. C) 50 40 T3C T4 EFG EFG YES YES 60 70 40 T3A T3C EFG EFG YES YES 85 100 40 T2C T2 EFG EFG YES YES 85 150 40 T2A T2B EFG YES YES 90 100 40 T2B T2C EFG EFG YES YES 85 175 40 T2 T2B EFG YES YES 90 250 40 350 C 325 C EFG YES 110 70 40 T3C T2C EFG EFG YES YES 75 METAL 100 40 T3A T2C EFG EFG YES YES 75 HALIE 175 40 T2A T2C EFG YES YES 90 250 40 T2 T2 EFG YES 125 NOTES: 1.) Simultaneous Presence Applications: Some Hazlux 3 fixtures are UL Listed for simultaneous presence of gas and dust. Contact Hazlux for specific information. 2.) Tuffskin Coated Optics: Many Hazlux 3 fixtures are UL Listed with Tuffskin (silicone) coating on glass optics. Contact Hazlux for specific information. 3.) For UL & CSA Certification Information on other ambient temperatures and fixture configurations, consult the factory or refer to the Hazlux Application Guide (Order Number: H7027). HAZLUX 3 CERTIFICATION GUIE (40 C AMBIENT) R-TANK BALLAST HOUSING - 7-3/4'' THREA LAMP TYPE WATTS AMBIENT TEMP (eg. C) CLASS I, IVISION 2 CLASS II GROUPS A, B, C, IVISION 1 & 2 TEMPERATURE COE GROUPS UL 1598 VGT31S 7-3/4'' Globe, Guard & Reflector VGL31R5 7-3/4'' ia. Refractor Globe VGT31S 7-3/4'' Globe, Guard & Reflector VGL31R5 7-3/4'' ia. Refractor Globe MARINE* NEMA 4X* CHART B SUPPLY WIRE TEMP. RATING (eg. C) HIGH PRESSURE SOIUM MERCURY VAPOR 50 40 T3C T3C EFG EFG YES YES 60 70 40 T3A T3A EFG EFG YES YES 85 100 40 T2 T3 EFG EFG YES YES 85 150 40 T2B T2B EFG EFG YES YES 85 100 40 T2B T2B EFG EFG YES YES 85 175 40 T2 T2A EFG EFG YES YES 90 250 40 350 C 350 C EF EF YES 110 70 40 T3 T3 EFG EFG YES YES 75 METAL 100 40 T3 T3 EFG EFG YES YES 75 HALIE 175 40 T2B T2B EFG EFG YES YES 90 250 25 T2 T2 EFG YES 90 NOTES: 1.) Simultaneous Presence Applications: Many Hazlux 3 fixtures are UL Listed for simultaneous presence of gas and dust. Contact Hazlux for specific information. 2.) Tuffskin Coated Optics: Many Hazlux 3 fixtures are UL Listed with Tuffskin (silicone) coating on glass optics. Contact Hazlux for specific information. 3.) For UL & CSA Certification Information on other ambient temperatures and fixture configurations, consult the factory or refer to the Hazlux Application Guide (Order Number: H7027). * NOTE REGARING GLASS GLOBES AN REFRACTORS All Hazlux fixture assemblies shown in this Buyers Guide as UL Listed or CSA Certified for Marine applications are suitable for hosedown when fixture is off and glass has been allowed to cool. Tempered glass globes and refractors have better thermal shock resistance properties than non-tempered globes and refractors and should be considered whenever fixtures are subject to being splashed with significantly cooler liquids while illuminated (hot). Consult factory for more information. 6 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

HAZLUX 3 CERTIFICATION GUIE (40 C AMBIENT) LARGE BALLAST HOUSING - 7-3/4'' THREA LAMP TYPE WATTS AMBIENT TEMP (eg. C) VGT31 Globe With Guard & Reflector CLASS I, IVISION 2 CLASS II GROUPS A, B, C, IVISION 1 & 2 TEMPERATURE COE GROUPS UL 1598 VRF31C5 12'' ia. Refractor Reflector with Lens VGT31 Globe With Guard & Reflector VRF31C5 12'' ia. Refractor Reflector with Lens General Information MARINE* CHART C NEMA 4X* SUPPLY WIRE TEMP. RATING (eg. C) HIGH 200 40 T2 T2A T2A EFG EFG EFG YES YES 90 PRESSURE 250 40 325 C 325 C 325 C EFG EFG EFG YES YES 90 SOIUM 400 40 T2A T2B T2B EFG EF YES 110 MERCURY 250 40 350 C 325 C 350 C EF EFG EFG YES 110 VAPOR 400 40 350 C 325 C 350 C EF EFG EF YES 110 Hazlux METAL 250 40 T2 T2A T2A EFG EFG YES 90 HALIE 400 40 350 C 325 C 325 C EFG EF YES 110 NOTES: 1.) 400 Watt HPS T-numbers based on BT/E/E 37 diffuse coated lamp. Contact Hazlux for certification information when using other lamps. 2.) Simultaneous Presence Applications: Some Hazlux 3 fixtures are UL Listed for simultaneous presence of gas and dust. Contact Hazlux for specific information. 3.) Tuffskin Coated Optics: Many Hazlux 3 fixtures are UL Listed with Tuffskin (silicone) coating on glass optics. Contact Hazlux for specific information. 4.) For UL & CSA Certification Information on other ambient temperatures and fixture configurations, consult the factory or refer to the Hazlux Application Guide (Order Number: H7027). HAZLITE TM M3 CERTIFICATION GUIE (40 C AMBIENT) The data listed in the table below is for UL844/595 listing at 40 C Ambient. FIXTURE TYPE WATTS SERIES CLASS I, IVISION 2 GROUPS A, B, C, TEMPERATURE COE Globe & Guard With or Without Reflector 8'' Refractor CLASS II, IVISION 1 & 2 GROUPS Globe & Guard With or Without Reflector 8'' Refractor CLASS III, IVISION 1 & 2 Globe & Guard With or Without Reflector 8'' Refractor NEMA 4X (Suitable for Hosedown)* CHART MARINE LISTE (UL 1598)* 35 SM T3A T3A EF&G EF&G Yes Yes Yes Yes HIGH 50 SM T3 T3 EF&G EF&G Yes Yes Yes Yes PRESSURE 70 SM T2B T2B EF&G EF&G Yes Yes Yes Yes SOIUM 100 SM T2A T2A E&F EF&G Yes Yes Yes 150 SM 325 C 325 C E&F EF&G Yes Yes MERCURY VAPOR 50 MM T2B T2B EF&G EF&G Yes Yes Yes Yes 75 MM T2 T2 EF&G EF&G Yes Yes Yes Yes 100 MM 325 C 325 C E&F EF&G Yes Yes 9 FB T3C T3C EF&G EF&G Yes Yes Yes Yes FLUORES- 13 FB T3C T3C EF&G EF&G Yes Yes Yes Yes CENT 18 FB T3C T3C EF&G EF&G Yes Yes Yes Yes 26 FB T3 T3 EF&G EF&G Yes Yes Yes Yes INCANES- CENT 60 IM T3 T3 E&F EF&G Yes Yes Yes 100 IM T3 T3 E&F EF&G Yes Yes Yes 150 IM T2B T2B EF&G Yes Yes Yes * NOTE REGARING GLASS GLOBES AN REFRACTORS All Hazlux fixture assemblies shown in this Buyers Guide as UL Listed or CSA Certified for Marine applications are suitable for hosedown when fixture is off and glass has been allowed to cool. Tempered glass globes and refractors have better thermal shock resistance properties than non-tempered globes and refractors and should be considered whenever fixtures are subject to being splashed with significantly cooler liquids while illuminated (hot). Consult factory for more information. 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 7

General Information HAZLUX 5 CERTIFICATION GUIE (40 C AMBIENT) CHART E FIXTURE TYPE WATTS CLASS I, IV. 1, GROUPS C & CLASS II, IV. 1 & 2 Rated Temp C T No. Rated Temp C Groups CLASS III, IV. 1 & 2 NEMA 4X (Suitable for Hosedown)* MARINE LISTE (UL 595)* Hazlux High Pressure Sodium Mercury Vapor Metal Halide 50 85 T6 100 EFG Yes Yes Yes 70 85 T6 120 EFG Yes Yes Yes (With or 100 100 T5 135 EFG Yes Yes Yes Without 150(S55) 120 T4A 160 EFG Yes Yes Yes Instant 150(S56) 120 T4A 160 EFG Yes Yes Yes Restart) 250 120 T4A Yes Yes 400 160 T3C Yes Yes 50 120 T4A 160 EFG Yes Yes Yes With 70 120 T4A 160 EFG Yes Yes Yes Auxiliary 100 160 T3C 200 EF Yes Yes Quartz 150(S55) 160 T3C 200 EF Yes Yes 150(S56) 160 T3C Yes Yes 100 100 T5 135 EFG Yes Yes Yes 175 135 T4 180 EF Yes Yes 250 160 T3C 200 EF Yes Yes 400 180 T3A Yes Yes With 100 160 T3C 200 EF Yes Yes Auxiliary 175 180 T3A Yes Yes Quartz 250 180 T3A Yes Yes 100 175 120 T4A 180 EF Yes Yes 250 160 T3C 200 EF Yes Yes 400 165 T3B Yes Yes With 175 160 T3C Yes Yes Auxiliary 250 180 T3A Yes Yes Quartz * NOTE REGARING GLASS GLOBES AN REFRACTORS All Hazlux fixture assemblies shown in this Buyers Guide as UL Listed or CSA Certified for Marine applications are suitable for hosedown when fixture is off and glass has been allowed to cool. Tempered glass globes and refractors have better thermal shock resistance properties than non-tempered globes and refractors and should be considered whenever fixtures are subject to being splashed with significantly cooler liquids while illuminated (hot). Consult factory for more information. These fixtures suitable (UL Listed) for use in paint spray areas, add suffix PS to the number. 100W MH is UL listed for paint spray. 8 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

HAZLITE TM M5 CERTIFICATION GUIE (40 C AMBIENT) FIXTURE TYPE WATTS CLASS I, IV. 1, GROUPS C & CLASS 1, IV. 2, GROUPS A,B,C& CLASS II, IV. 1 & 2 Rated Temp C T No. Rated Temp C Groups General Information CLASS III, IV. 1 & 2 NEMA 4X* CHART F MARINE LISTE (UL 1598)* High Pressure Sodium Mercury Vapor Incand. Fluor. UL Listed at 25 C 35 85 T6 100 EFG Yes Yes Yes 50 85 T6 120 EFG Yes Yes Yes 70 100 T5 135 EFG Yes Yes Yes 100 120 T4A 160 EFG Yes Yes Yes 150 135 T4 Yes Yes 50 100 T5 120 EFG Yes Yes Yes 75 120 T4A 160 EFG Yes Yes Yes 100 135 T4A 160 EFG Yes Yes Yes 100 100 T5 160 EFG Yes Yes Yes 150 120 T4A 200 EF Yes Yes 18 85 T6 85 EFG Yes Yes Yes 26 85 T6 85 EFG Yes Yes Yes Hazlux These fixtures suitable (UL Listed) for use in paint spray areas, add suffix PS to the catalog number. Fluorescents T-Code will be T4A. * NOTE REGARING GLASS GLOBES AN REFRACTORS All Hazlux fixture assemblies shown in this Buyers Guide as UL Listed or CSA Certified for Marine applications are suitable for hosedown when fixture is off and glass has been allowed to cool. Tempered glass globes and refractors have better thermal shock resistance properties than non-tempered globes and refractors and should be considered whenever fixtures are subject to being splashed with significantly cooler liquids while illuminated (hot). Consult factory for more information. T - Number Table T - NUMBER MAXIMUM TEMPERATURE C T - NUMBER MAXIMUM TEMPERATURE C T1 450 T3A 180 T2 300 T3B 165 T2A 280 T3C 160 T2B 260 T4 135 T2C 230 T4A 120 T2 215 T5 100 T3 200 T6 85 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 9

General Information Hazardous Locations HAZAROUS LOCATION An area where the possibility of explosion and fire is created by the presence of flammable gases, vapors, dust, fibers or flyings. CLASS I-Gas CLASS I (NEC-500-5) Those areas in which flammable gases or vapors may be present in the air in sufficient quantities to be explosive or ignitable. Typical Class I Locations: Petroleum refineries, and gasoline storage and dispensing areas. Industrial firms that use flammable liquids in dip tanks for parts cleaning or other operations. Petrochemical companies that manufacture chemicals from gas and oil. ry cleaning plants where vapors from cleaning fluids can be present. Companies that have spraying areas where they coat products with paint or plastics. Aircraft hangars and fuel serving areas. Utility gas plants and operations involving storage and handling of liquified petroleum gas or natural gas. IVISION 1-Normally Hazardous IVISION 1 Hazardous gases or dusts are present under normal operation conditions or during frequent repair and maintenance activity. GROUPS A-B-C- GROUPS (NEC-500-2 & 502-1) The gases and vapors of Class I locations are broken into four groups by the code A, B, C and. These materials are grouped according to: the ignition temperature of the substance, its explosion pressure and other flammable characteristics. GROUPS E-F-G CLASS II dust locations-groups E, F and G. These groups are classified according to the ignition temperature and the conductivity of the hazardous substance. Hazlux CLASS II-ust CLASS II (NEC-500-6) Those areas made hazardous by the presence of combustible dust. Typical Class II Locations: Grain elevators, flour and feed mills. Plants that manufacture, use or store magnesium or aluminum powders. Plants that have chemical or metallurgical processes: producers of plastics, medicines and fireworks, etc. Producers of starch or candies. Spice-grinding plants, sugar plants and cocoa plants. Coal preparation plants and other carbon handling or processing areas. IVISION 2-Not Normally Hazardous IVISION 2 Hazardous gases or dusts are not present under normal operating conditions. ARTICLES 500 Through 505 (1996 NEC) Explains in detail the requirements for the installation of wiring or electrical equipment in hazardous locations. These articles along with other applicable regulations; local governing inspection authorities, insurance representatives, and qualified engineering/technical assistance should be your guides to the installation of wiring or electrical equipment in any hazardous or potentially hazardous location. CLASS III-Fibers CLASS III (NEC-500-7) Those areas in which there are easily ignitable fibers or flyings present, due to type of material being handled, stored, or processed. Typical Class III Locations: Textile mills, cotton gins, cotton seed mills and flax processing plants. Any plant that shapes, pulverizes or cuts wood and creates sawdust or flyings. NOTE: Fibers and flyings are not likely to be suspended in the air, but can collect around machinery or on lighting fixtures and where heat, a spark or hot metal can ignite them. Note: These are simplified definitions - complete data is available in the referenced 1996 NEC. 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 11

General Information Ignition Temperatures and Group Classifications for Flammable Gases and Vapors Hazlux MATERIAL GROUP AUTOIGNITION TEMPERATURE EGREES F EGREES C ACETALEHYE C 347 175 ACETIC ACI 867 464 ACETIC ANHYRIE 600 316 ACETONE 869 465 ACETONE CYANOHYRIN 1270 688 ACETONITRILE 975 524 ACETYLENE A 581 305 ACROLEIN (INHIBITE) B(C) 455 285 ACRYLIC ACI 820 438 ACRYLONITRILE 898 481 ALLYL ALCOHOL C 713 378 ALLYL CHLORIE 905 485 ALPHA-METHYL STYRENE 1066 574 AMMONIA 928 498 n-amyl ACETATE 680 360 ANILINE 1139 615 BENZENE 928 498 BENZYL CHLORIE 1085 585 1.3-BUTAIENE B() 788 420 BUTANE 550 288 1-BUTANOL 650 343 2-BUTANOL 761 405 n-butyl ACETATE 790 421 n-butyl ACRYLATE (INHIBITE) 559 293 BUTYLAMINE 594 312 BUTYLENE 725 385 n-butyralehye C 425 218 n-butyric ACI 830 443 CARBON ISULFIE * 194 90 CARBON MONOXIE C 1128 609 CHLOROBENZENE 1099 593 CRESOL 1038-1110 559-599 CROTONALEHYE C 450 232 CUMENE 795 424 CYCLOHEXANE 473 245 CYCLOHEXANOL 572 300 CYCLOHEXANONE 473 245 CYCLOHEXENE 471 244 CYCLOPROPANE 938 503 p-cymene 817 436 n-ecanol 550 288 ECENE 455 235 I-ISOBUTYL KETONE 745 396 *Carbon isulfide has characteristics which require safeguards beyond those required for any of the above groups. 12 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

General Information Ignition Temperatures and Group Classifications for Flammable Gases and Vapors (continued) MATERIAL GROUP AUTOIGNITION TEMPERATURE EGREES F EGREES C I-ISOBUTYLENE 736 391 I-N-PROPYLAMINE C 570 299 IACETONE ALCOHOL 1118 603 o-ichlorobenzene 1198 647 1.1-ICHLOROETHANE 820 438 1.2-ICHLOROETHYLENE 860 460 ICYLOPENTAIENE C 937 503 IETHYL BENZENE 743-842 395-450 IETHYL ETHER C 320 160 IETHYLAMINE C 594 312 IETHYLENE GLYCOL MONOBUTYL ETHER C 442 228 IETHYLENE GLYCOL MONOMETHYL ETHER C 465 241 n-n-imethyl ANILINE C 700 371 IMETHYL FORMAMIE 833 455 IMETHYL SULFATE 370 188 IMETHYLAMINE C 752 400 1,4-IOXANE C 356 180 IPENTENE 458 237 OECENE 491 255 U-ISOPROPYLAMINE C 600 316 EPICHLOROHYRIN C 772 411 ETHANE 882 472 ETHANOL 685 363 ETHYL ACETATE 800 427 ETHYL ACETATE (INHIBITE) 702 372 ETHYL BENZENE 810 432 ETHYL CHLORIE 966 519 ETHYL FORMATE 851 455 2-ETHYL HEXANOL 448 231 2-ETHYL HEXYL ACRYLATE 485 252 ETHYL MERCAPTAN C 572 300 ETHYLAMINE 725 385 ETHYLENE C 842 450 ETHYLENE CHLOROHYRIN 797 425 ETHYLENE ICHLORIE 775 413 ETHYLENE GLYCOL MONOBUTYL ETHER C 460 238 ETHYLENE GLYCOL MONOBUTYL ETHER ACETATE C 645 340 ETHYLENE GLYCOL MONOETHYL ETHER C 455 235 ETHYLENE GLYCOL MONOETHYL ETHER ACETATE C 715 379 ETHYLENE GLYCOL MONOMETHYL ETHER 545 285 ETHEYLENE OXIE B(C) 804 429 ETHYLENEIAMINE 725 385 ETHYLENIMINE C 608 320 2-ETHYLEHEXALEHYE C 375 191 FORMALEHYE (GAS) B 795 429 FORMIC ACI (90%) 813 434 Hazlux 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 13

General Information Ignition Temperatures and Group Classifications for Flammable Gases and Vapors (continued) Hazlux MATERIAL GROUP AUTOIGNITION TEMPERATURE EGREES F EGREES C FUEL OILS 410-765 210-407 FURFURAL C 600 316 FURFURYL ALCOHOL C 915 490 GASOLINE 536-880 280-471 HEPTANE 399 204 HEPTENE 500 260 HEXANE 437 225 2-HEXANONE 795 424 HEXENES 473 245 HYRAZINE C 74-518 23-270 HYROGEN B 968 520 HYROGEN CYANIE C 1000 538 HYROGEN SULFIE C 500 260 ISO-BUTYL ACETATE 790 421 ISO-OCTYL ALEHYE C 387 197 ISOAMYL ACETATE 680 360 ISOAMYL ALCOHOL 662 350 ISOBUTYL ACRYLATE 800 427 ISOBUTYRALEHYE C 385 196 ISOPHORONE 860 460 ISOPRENE 428 220 ISOPROPYL ACETATE 860 460 ISOPROPYL ETHER 830 443 ISOPROPYLAMINE 756 402 KEROSENE 410 210 LIQUIFIE PETROLEUM GAS 761-842 405-450 MESITYL OXIE 652 344 METHANE 999 537 METHANOL 725 385 METHYL ACETATE 850 454 METHYL ACRYLATE 875 468 METHYL ETHER C 662 350 METHYL ETHYL KETONE 759 404 METHYL FORMAL C 460 238 METHYL FORMATE 840 449 METHYL ISOBUTYL KETONE 840 449 METHYL ISOCYANATE 994 534 METHYL METHACRYLATE 792 422 METHYL N-AMYL KETONE 740 393 2-METHYL-1-PROPANOL 780 416 2-METHYL-2-PROPANOL 892 478 METHYLAMINE 806 430 METHYLCYCLOHEXANE 482 250 METHYLCYCLOHEXANOL 565 296 14 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

General Information Ignition Temperatures and Group Classifications for Flammable Gases and Vapors (continued) MATERIAL GROUP AUTOIGNITION TEMPERATURE EGREES F EGREES C MONOETHANOLAMINE 770 410 MONOISOPROPANOLAMINE 705 374 MONOMETHYL ANILINE C 900 482 MONOMETHYL HYRAZINE C 382 194 MORPHOLINE C 590 310 NAPHTHA (COAL TAR) 531 277 NAPHTHA (PETROLEUM) 550 288 NITROBENZENE 900 482 NITROETHANE C 778 414 NITROMETHANE C 785 418 2-NITROPROPANE C 802 428 1-NITROPROPANE C 789 421 NONANE 401 205 OCTANE 403 206 OCTENE 446 230 PENTANE 470 243 1-PENTANOL 572 300 2-PENTANONE 846 452 1-PENTENE 527 275 PROPANE 842 450 2-PROPANOL 750 399 1-PROPANOL 775 413 PROPIONALEHYE C 405 207 PROPRIONIC ACI 870 466 PROPRIONIC ANHYRIE 545 285 n-propyl ACETATE 842 450 n-propyl ETHER C 419 215 PROPYL NITRATE B 347 175 PROPYLENE 851 455 PROPYLENE ICHLORIE 1035 537 PROPYLENE OXIE B(C) 840 449 PYRIINE 900 482 STYRENE 914 490 TETRAHYROFURAN C 610 321 TETRAHYRONAPTHALENE 725 385 TOLUENE 896 480 TURPENTINE 488 253 UNSYMMETRICAL IMETHYL HYRAZINE (UMH) C 480 249 VALERALEHYE C 432 222 VINYL ACETATE 756 402 VINYL CHLORIE 882 472 VINYL TOLUENE 921 494 VINYLIENE CHLORIE 1058 570 XYLENES 867-984 464-529 Hazlux 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 15

Polymeric Fixtures POLYMERIC FIXTURES for CLASS I, IVISION 2; WET and MARINE LOCATIONS* CONTENTS PAGE Hazlux 1...19 HI, Mogul Base; 50-175W Hazlux Hazlite M1...31 HI, Medium Base; 35-100W Compact Fluorescent Hazlux LumaShield...149 Polymeric Wash-own Fluorescent *Check individual product listings for specific suitabilities. 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 17

Polymeric Fixtures CATALOG NUMBERING SYSTEM Hazlux 1 UL844 Class I, ivision 2, Groups A,B,C,* Enclosed and Gasketed UL 1598, Suitable for Wet Locations UL 1598 Marine NEMA 4X 50-175 Watts Catalog Numbering System P S 0 07 H 04 0 - R5P -S5E 4 F 1 2 3 4 5 6 7 8 9 10 11 12 Hazlux 1) Hazlux Fixture Series P = Polymeric Fixture Suitable for Class I, ivision 2 and Marine Locations 2) Lamp Type S = High Pressure Sodium H = Metal Halide M = Mercury Vapor 3) Starter Circuit Options 0 = Standard Fixture J = Auto-Shutoff 4) Lamp Wattage 05 = 50 Watts 07 = 70 Watts 10 = 100 Watts 15 = 150 Watts 17 = 175 Watts 5) Ballast Circuit C = Constant Wattage Autotransformer (CWA) H = High Reactance P = Reactor (All Ballasts are High Power Factor.) 6) Voltage 03 = 120/277 Volts 04 = 120/208/240/277 Volts 12 = 120 Volts 27 = 277 Volts 48 = 480 Volts (Contact factory for other available voltages.) 7) Ballast Housing Style 0 = Standard Housing 8) Optical Assembly TG = Heat Resistant Globe TGP = Heat Resistant Glass Globe with Polymeric Guard SG = Tuffskin Coated Glass Globe SGP = Tuffskin Coated Glass Globe with Polymeric Guard R1P = Type I Refractor Globe with Polymeric Guard R3P = Type III Refractor Globe with Polymeric Guard R5P = Type V Refractor Globe with Polymeric Guard 9) Mounting Style P2 = 3/4'' Pendant C2 = 3/4'' Ceiling (Feed Through) B2 = 3/4'' Wall S5 = 1-1/2'' Angle Stanchion L5 = 1-1/2'' Straight Stanchion 10) UNIPAK Options E = Unipak with Clear Lamp = Unipak with iffuse Coated Lamp U = Unipak without Lamp 11) Reflector Options 4 = ome Reflector 5 = Angle Reflector 12) Fusing Options (Not Marine Rated) F = Single Fuse Block FF = ouble Fuse Block Tuffskin is a registered trademark of Thomas Manufacturing Corporation. * See page 9 for T-Code Ratings 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 19

Hazlux Polymeric Fixtures POLYMERIC FIXTURE COMPONENTS Hazlux 1 UL 844 Class I, ivision 2, Groups A, B, C, * Enclosed and Gasketed UL 1572, Suitable for Wet Locations UL 595 Marine* NEMA 4X* 50-175 Watts OUTLET BOXES esigned for all Hazlux 1 Ballast Housings. MOUNTING CATALOG CONUIT WT. EA. ST. STYLE NUMBER HUB SIZE (LBS.) PKG. Rigid Pendant MOUNTING CATALOG CONUIT WT. EA. ST. STYLE NUMBER HUB SIZE (LBS.) PKG. Angle Stanchion VNP2 3/4'' 2.6 1 VNS5 1-1/2'' 5 1 Ceiling Mount VNC2 3/4'' 3.4 1 Straight Stanchion VNL5 1-1/2'' 5 1 Wall Mount VNB2 3/4'' 7 1 BALLAST HOUSING HIGH PRESSURE SOIUM High Reactance or Constant Wattage Ballast (Min. P.F. 90%) WATTAGE VOLTAGE WT. EACH (Lbs.) CATALOG NUMBER ST. PKG. LISTING & NEC REQUIRE MARKING ON FIXTURE Enclosed & Gasketed Suitable for Wet Locations Class 1 ivision 2 40 C Ambient Marine (UL595) Listed 50 120/277 15 PS005H03 1 70 120/208/240/277 15 PS007H04 1 70 480 15 PS007H48 1 100 120/208/240/277 17 PS010H04 1 100 480 17 PS010H48 1 150 120/208/240/277 18 PS015H04 1 150 480 18 PS015H48 1 * See Page 5 for Note Regarding Glass Globes and Refractors. For use with 55V (ANSI S55) lamp only. For use with a 100V (ANSI S56) lamp, substitute the letter C for the letters S and H in the catalog number. * See page 9 for T-Code Ratings 20 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Polymeric Fixtures POLYMERIC FIXTURE COMPONENTS Hazlux 1 UL 844 Class I, ivision 2, Groups A, B, C, * Enclosed and Gasketed UL 1572, Suitable for Wet Locations UL 595 Marine* NEMA 4X* 50-175 Watts BALLAST HOUSING METAL HALIE Constant Wattage Autotransformer Ballast (Min. P.F. 90%) WATTAGE VOLTAGE WT. EACH (Lbs.) CATALOG NUMBER ST. PKG. LISTING & NEC REQUIRE MARKING ON FIXTURE Enclosed & Gasketed Suitable for Wet Locations Class 1 ivision 2 40 C Ambient Marine Listed Hazlux 70 120 14 PH007H12 1 70 120/277 14 PH007H04 1 100 120 15.5 PH010H12 1 100 120/277 15.5 PH010H04 1 175 120/208/240/277 17 PH010C04 1 175 480 17 PH017C48 1 BALLAST HOUSING MERCURY VAPOR Constant Wattage Autotransformer Ballast (Min. P.F. 90%) WATTAGE VOLTAGE WT. EACH (Lbs.) CATALOG NUMBER ST. PKG. LISTING & NEC REQUIRE MARKING ON FIXTURE Enclosed & Gasketed Suitable for Wet Locations Class 1 ivision 2 40 C Ambient 100 120/208/240/277 14 PM010C04 1 100 480 14 PM010C48 1 Marine Listed 175 120/208/240/277 16 PM017C04 1 175 480 16 PM017C48 1 See Page 5 for Note Regarding Glass Globes and Refractors. * See page 9 for T-Code Ratings 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 21

Hazlux Polymeric Fixtures POLYMERIC FIX- TURE COMPONENTS Hazlux 1 UL 844 Class I, ivision 2, Groups A,B,C,* Enclosed and Gasketed UL 1572, Suitable for Wet Locations UL 595 Marine* NEMA 4X* 50-175 Watts GLOBES ESCRIPTION WT. EA. (LBS.) VGT31S Heat Resistant Glass (7 3 4'' dia.) 250 Watt Max. 9 VGT31STS Heat Resistant Glass (7 3 4'' dia.) Coated with Tuff-Skin, 250 Watt Max. 9.2 GUARS ESCRIPTION WT. EA. (LBS.) VGU31RP For use with Threaded Glass Globes and Refractors (7 3 4'' dia.) Polymeric 2 REFLECTORS ESCRIPTION WT. EA. (LBS.) Standard ome VR31P Fiberglass Reinforced Polyester 3 For use with 7 3 4'' dia. Globes 30 Angle Reflector VRA31P Fiberglass Reinforced Polyester 3 For use with 7 3 4'' dia. Globes REFRACTORS ESCRIPTION WT. EA. (LBS.) VGL31R1 VGL31R3 VGL31R5 See Page 5 for Note Regarding Glass Globes and Refractors. * * See page 9 for T-Code Ratings IES Type I Light istribution (Long and Narrow) Threaded Glass Globe Refractor 7 3 4'' dia. IES Type III Light istribution (Asymmetric) Threaded Glass Globe Refractor 7 3 4'' dia. IES Type V Light istribution (Symmetric) Threaded Glass Globe Refractor 7 3 4'' dia. 8 8 8 22 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Polymeric Fixtures POLYMERIC FIX- TURE COMPONENTS Hazlux 1 UL 844 Class I, ivision 2, Groups A,B,C,* Enclosed and Gasketed UL 1572, Suitable for Wet Locations UL 595 Marine* NEMA 4X* 50-175 Watts NOTES: Hazlux * See page 9 for T-Code Ratings 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 23

Hazlux Polymeric Fixtures POLYMERIC HIGH PRESSURE SOI- UM WITH GLOBE AN GUAR Hazlux 1 50-150 Watts UL 844 Class I, ivision 2, Groups A, B, C, * Enclosed and Gasketed UL 1572, Suitable for Wet Locations UL 595 Marine* NEMA 4X* MOUNTING STYLE LAMP WATTS CONUIT SIZE (Inches) 120/208/240/277V WT. EACH (Lbs.) Ballast Housing CONSISTS OF: Outlet Box Globe Guard Rigid Pendant 70 3/4 PS007H040-TGP-P2 22 PS007H04 VNP2 VGT31S VGU31RP 100 3/4 PS010H040-TGP-P2 24 PS010H04 VNP2 VGT31S VGU31RP 150 3/4 PS015H040-TGP-P2 25 PS015H04 VNP2 VGT31S VGU31RP Ceiling Mount 70 3/4 PS007H040-TGP-C2 23 PS007H04 VNC2 VGT31S VGU31RP 100 3/4 PS010H040-TGP-C2 25 PS010H04 VNC2 VGT31S VGU31RP 150 3/4 PS015H040-TGP-C2 26 PS015H04 VNC2 VGT31S VGU31RP Wall Mount 70 3/4 PS007H040-TGP-B2 26 PS007H04 VNB2 VGT31S VGU31RP 100 3/4 PS010H040-TGP-B2 28 PS010H04 VNB2 VGT31S VGU31RP 150 3/4 PS015H040-TGP-B2 29 PS015H04 VNB2 VGT31S VGU31RP Angle Stanchion 70 1-1/2 PS007H040-TGP-S5 24 PS007H04 VNS5 VGT31S VGU31RP 100 1-1/2 PS010H040-TGP-S5 26 PS010H04 VNS5 VGT31S VGU31RP 150 1-1/2 PS015H040-TGP-S5 27 PS015H04 VNS5 VGT31S VGU31RP Straight Stanchion 70 1-1/2 PS007H040-TGP-L5 24 PS007H04 VNL5 VGT31S VGU31RP 100 1-1/2 PS010H040-TGP-L5 26 PS010H04 VNL5 VGT31S VGU31RP 150 1-1/2 PS015H040-TGP-L5 27 PS015H04 VNL5 VGT31S VGU31RP Standard ome Reflector: Angle Reflector: GUAR: If a guard is not required, delete P from the Catalog No. VR31P Catalog No. VRA31P Catalog Number. * See page 9 for T-Code Ratings 24 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Polymeric Fixtures POLYMERIC HIGH PRESSURE SOI- UM WITH REFRACTOR AN GUAR Hazlux 1 50-150 Watts UL 844 Class I, ivision 2, Groups A, B, C, * Enclosed and Gasketed UL 1572, Suitable for Wet Locations UL 595 Marine* NEMA 4X* MOUNTING STYLE LAMP WATTS CONUIT SIZE (Inches) 120/208/240/277V WT. EACH (Lbs.) Ballast Housing CONSISTS OF: Outlet Box Refractor Guard Rigid Pendant 70 3/4 PS007H040-R5P-P2 22 PS007H04 VNP2 VGL31R5 VGU31RP Hazlux 100 3/4 PS010H040-R5P-P2 24 PS010H04 VNP2 VGL31R5 VGU31RP 150 3/4 PS015H040-R5P-P2 25 PS015H04 VNP2 VGL31R5 VGU31RP Ceiling Mount 70 3/4 PS007H040-R5P-C2 23 PS007H04 VNC2 VGL31R5 VGU31RP 100 3/4 PS010H040-R5P-C2 25 PS010H04 VNC2 VGL31R5 VGU31RP 150 3/4 PS015H040-R5P-C2 26 PS015H04 VNC2 VGL31R5 VGU31RP Wall Mount 70 3/4 PS007H040-R5P-B2 26 PS007H04 VNB2 VGL31R5 VGU31RP 100 3/4 PS010H040-R5P-B2 28 PS010H04 VNB2 VGL31R5 VGU31RP 150 3/4 PS015H040-R5P-B2 29 PS015H04 VNB2 VGL31R5 VGU31RP Angle Stanchion 70 1-1/2 PS007H040-R5P-S5 24 PS007H04 VNS5 VGL31R5 VGU31RP 100 1-1/2 PS010H040-R5P-S5 26 PS010H04 VNS5 VGL31R5 VGU31RP 150 1-1/2 PS015H040-R5P-S5 27 PS015H04 VNS5 VGL31R5 VGU31RP Straight Stanchion 70 1-1/2 PS007H040-R5P-L5 24 PS007H04 VNL5 VGL31R5 VGU31RP 100 1-1/2 PS010H040-R5P-L5 26 PS010H04 VNL5 VGL31R5 VGU31RP 150 1-1/2 PS015H040-R5P-L5 27 PS015H04 VNL5 VGL31R5 VGU31RP Standard ome Reflector: Angle Reflector: GUAR: If a guard is not required, delete P from the Catalog No. VR31P Catalog No. VRA31P Catalog Number. All fixtures are designed for mogul base lamps, with the lamp mounted in the base-up position (lamps are NOT furnished with fixture). Catalog Number with Multi-tap Ballast. For other ballast voltages refer to Catalog Format Page. For use with 55V (ANSI S55) lamps only. If a fixture or housing is required for use with a 100V (ANSI S56) lamp, substitute the letter C for the letters S and H in the Catalog Number. See Page 5 for Note Regarding Glass Globes and Refractors. * Refractors are closed-bottom prismatic glass Type V. Other types of refractors are available. See page A4. * See page 9 for T-Code Ratings 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 25

Hazlux Polymeric Fixtures POLYMERIC METAL HALIE WITH GLOBE AN GUAR Hazlux 1 UL 844 Class I, ivision 2, Groups A, B, C, * Enclosed and Gasketed UL 1572, Suitable for Wet Locations UL 595 Marine* NEMA 4X* 70-175 Watts MOUNTING STYLE LAMP WATTS CONUIT SIZE (Inches) 120/208/240/277V WT. EACH (Lbs.) Ballast Housing CONSISTS OF: Outlet Box Globe Guard Rigid Pendant 70 3/4 PH007H040-TGP-P2 22 PH007H04 VNP2 VGT31S VGU31RP 100 3/4 PH010H040-TGP-P2 24 PH010H04 VNP2 VGT31S VGU31RP 175 3/4 PH017C040-TGP-P2 25 PH017C04 VNP2 VGT31S VGU31RP Ceiling Mount 70 3/4 PH007H040-TGP-C2 23 PH007H04 VNC2 VGT31S VGU31RP 100 3/4 PH010H040-TGP-C2 25 PH010H04 VNC2 VGT31S VGU31RP 175 3/4 PH017C040-TGP-C2 26 PH017C04 VNC2 VGT31S VGU31RP Wall Mount 70 3/4 PH007H040-TGP-B2 26 PH007H04 VNB2 VGT31S VGU31RP 100 3/4 PH010H040-TGP-B2 28 PH010H04 VNB2 VGT31S VGU31RP 175 3/4 PH017C040-TGP-B2 29 PH017C04 VNB2 VGT31S VGU31RP Angle Stanchion 70 1-1/2 PH007H040-TGP-S5 24 PH007H04 VNS5 VGT31S VGU31RP 100 1-1/2 PH010H040-TGP-S5 26 PH010H04 VNS5 VGT31S VGU31RP 175 1-1/2 PH017C040-TGP-S5 27 PH017C04 VNS5 VGT31S VGU31RP Straight Stanchion 70 1-1/2 PH007H040-TGP-L5 24 PH007H04 VNL5 VGT31S VGU31RP 100 1-1/2 PH010H040-TGP-L5 26 PH010H04 VNL5 VGT31S VGU31RP 175 1-1/2 PH017C040-TGP-L5 27 PH017C04 VNL5 VGT31S VGU31RP Standard ome Reflector: Angle Reflector: GUAR: If a guard is not required, delete P from the Catalog No. VR31P Catalog No. VRA31P Catalog Number. All fixtures are designed for mogul base lamps, with the lamp mounted in the base-up position (lamps are NOT furnished with fixture). Catalog Number with Multi-tap Ballast. For other ballast voltages refer to Catalog Format Page. See Page 5 for Note Regarding Glass Globes and Refractors. * * See page 9 for T-Code Ratings 26 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Polymeric Fixtures POLYMERIC METAL HALIE WITH REFRACTOR AN GUAR Hazlux 1 UL 844 Class I, ivision 2, Groups A, B, C, * Enclosed and Gasketed UL 1572, Suitable for Wet Locations UL 595 Marine* NEMA 4X* 70-175 Watts MOUNTING STYLE LAMP WATTS CONUIT SIZE (Inches) 120/208/240/277V WT. EACH (Lbs.) Ballast Housing CONSISTS OF: Outlet Box Refractor Guard Rigid Pendant 70 3/4 PH007H040-R5P-P2 22 PH007H04 VNP2 VGL31R5 VGU31RP Hazlux 100 3/4 PH010H040-R5P-P2 24 PH010H04 VNP2 VGL31R5 VGU31RP 175 3/4 PH017C040-R5P-P2 25 PH017C04 VNP2 VGL31R5 VGU31RP Ceiling Mount 70 3/4 PH007H040-R5P-C2 23 PH007H04 VNC2 VGL31R5 VGU31RP 100 3/4 PH010H040-R5P-C2 25 PH010H04 VNC2 VGL31R5 VGU31RP 175 3/4 PH017C040-R5P-C2 26 PH017C04 VNC2 VGL31R5 VGU31RP Wall Mount 70 3/4 PH007H040-R5P-B2 26 PH007H04 VNB2 VGL31R5 VGU31RP 100 3/4 PH010H040-R5P-B2 28 PH010H04 VNB2 VGL31R5 VGU31RP 175 3/4 PH017C040-R5P-B2 29 PH017C04 VNB2 VGL31R5 VGU31RP Angle Stanchion 70 1-1/2 PH007H040-R5P-S5 24 PH007H04 VNS5 VGL31R5 VGU31RP 100 1-1/2 PH010H040-R5P-S5 26 PH010H04 VNS5 VGL31R5 VGU31RP 175 1-1/2 PH017C040-R5P-S5 27 PH017C04 VNS5 VGL31R5 VGU31RP Straight Stanchion 70 1-1/2 PH007H040-R5P-L5 24 PH007H04 VNL5 VGL31R5 VGU31RP 100 1-1/2 PH010H040-R5P-L5 26 PH010H04 VNL5 VGL31R5 VGU31RP 175 1-1/2 PH017C040-R5P-L5 27 PH017C04 VNL5 VGL31R5 VGU31RP Standard ome Reflector: Angle Reflector: GUAR: If a guard is not required, delete P from the Catalog No. VR31P Catalog No. VRA31P Catalog Number. All fixtures are designed for mogul base lamps, with the lamp mounted in the base-up position (lamps are NOT furnished with fixture). Catalog Number with Multi-tap Ballast. For other ballast voltages refer to Catalog Format Page. See Page 5 for Note Regarding Glass Globes and Refractors. * Refractors are closed-bottom prismatic glass Type V. Other types of refractors are available. See page 22. * See page 9 for T-Code Ratings 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 27

Hazlux Polymeric Fixtures POLYMERIC MER- CURY VAPOR WITH GLOBE AN GUAR Hazlux 1 UL 844 Class I, ivision 2, Groups A, B, C, * Enclosed and Gasketed UL 1572, Suitable for Wet Locations UL 595 Marine* NEMA 4X* 100-175 Watts MOUNTING STYLE LAMP WATTS CONUIT SIZE (Inches) 120/208/240/277V WT. EACH (Lbs.) Ballast Housing CONSISTS OF: Outlet Box Globe Guard Rigid Pendant 100 3/4 PM010C040-TGP-P2 24 PM010C04 VNP2 VGT31S VGU31RP 175 3/4 PM017C040-TGP-P2 25 PM017C04 VNP2 VGT31S VGU31RP Ceiling Mount 100 3/4 PM010C040-TGP-C2 25 PM010C04 VNC2 VGT31S VGU31RP 175 3/4 PM017C040-TGP-C2 26 PM017C04 VNC2 VGT31S VGU31RP Wall Mount 100 3/4 PM010C040-TGP-B2 28 PM010C04 VNB2 VGT31S VGU31RP 175 3/4 PM017C040-TGP-B2 29 PM017C04 VNB2 VGT31S VGU31RP Angle Stanchion 100 1-1/2 PM010C040-TGP-S5 26 PM010C04 VNS5 VGT31S VGU31RP 175 1-1/2 PM017C040-TGP-S5 27 PM017C04 VNS5 VGT31S VGU31RP Straight Stanchion 100 1-1/2 PM010C040-TGP-L5 26 PM010C04 VNL5 VGT31S VGU31RP 175 1-1/2 PM017C040-TGP-L5 27 PM017C04 VNL5 VGT31S VGU31RP Standard ome Reflector: Angle Reflector: GUAR: If a guard is not required, delete P from the Catalog No. VR31P Catalog No. VRA31P Catalog Number. All fixtures are designed for mogul base lamps, with the lamp mounted in the base-up position (lamps are NOT furnished with fixture). Catalog Number with Multi-tap Ballast. For other ballast voltages refer to Catalog Format Page. See Page 5 for Note Regarding Glass Globes and Refractors. * * See page 9 for T-Code Ratings 28 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Polymeric Fixtures POLYMERIC MER- CURY VAPOR WITH REFRACTOR AN GUAR Hazlux 1 UL 844 Class I, ivision 2, Groups A, B, C, * Enclosed and Gasketed UL 1572, Suitable for Wet Locations UL 595 Marine* NEMA 4X* 100-175 Watts MOUNTING STYLE LAMP WATTS CONUIT SIZE (Inches) 120/208/240/277V WT. EACH (Lbs.) Ballast Housing CONSISTS OF: Outlet Box Refractor Guard Rigid Pendant 100 3/4 PM010C040-R5P-P2 24 PM010C04 VNP2 VGL31R5 VGU31RP Hazlux 175 3/4 PM017C040-R5P-P2 25 PM017C04 VNP2 VGL31R5 VGU31RP Ceiling Mount 100 3/4 PM010C040-R5P-C2 25 PM010C04 VNC2 VGL31R5 VGU31RP 175 3/4 PM017C040-R5P-C2 26 PM017C04 VNC2 VGL31R5 VGU31RP Wall Mount 100 3/4 PM010C040-R5P-B2 28 PM010C04 VNB2 VGL31R5 VGU31RP 175 3/4 PM017C040-R5P-B2 29 PM017C04 VNB2 VGL31R5 VGU31RP Angle Stanchion 100 1-1/2 PM010C040-R5P-S5 26 PM010C04 VNS5 VGL31R5 VGU31RP 175 1-1/2 PM017C040-R5P-S5 27 PM017C04 VNS5 VGL31R5 VGU31RP Straight Stanchion 100 1-1/2 PM010C040-R5P-L5 26 PM010C04 VNL5 VGL31R5 VGU31RP 175 1-1/2 PM017C040-R5P-L5 27 PM017C04 VNL5 VGL31R5 VGU31RP Standard ome Reflector: Angle Reflector: GUAR: If a guard is not required, delete P from the Catalog No. VR31P Catalog No. VRA31P Catalog Number. All fixtures are designed for mogul base lamps, with the lamp mounted in the base-up position (lamps are NOT furnished with fixture). Catalog Number with Multi-tap Ballast. For other ballast voltages refer to Catalog Format Page. See Page 5 for Note Regarding Glass Globes and Refractors. * Refractors are closed-bottom prismatic glass Type V. Other types of refractors are available. See page 22. * See page 9 for T-Code Ratings 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 29

Polymeric Fixtures CATALOG NUMBERING SYSTEM HI, FLUORESCENT Hazlite M1 9-100 Watts UL 1598 Suitable for Wet Locations UL 844, Class 1, ivision 2 Hazardous** Locations UL 1598 Marine* NEMA 4X* HAZLITE M1 Metal Halide or High Pressure Sodium P S M 07 P 12 - GGL - C2 F - CSA 1 2 3 4 5 6 7 8 9 10 Hazlux Fluorescent Only P F B 13 P 12 - GGL - C2 - CSA 1 2 3 4 5 6 7 8 10 1) Fixture Suitability P = Polymeric Fixture Suitable for Class I, iv. 2, Hazardous Location and Marine Applications. 2) Lamp Type H = Metal Halide S = High Pressure Sodium F = Fluorescent 3) Type Lampholder M = Medium Base Lampholder B = Bi Pin Type (Fluorescent) 4) Lamp Wattage 09 = 9 Watts (Fluorescent) 13 = 13 Watts (Fluorescent) 18 = 18 Watts (Fluorescent) 26 = 26 Watts (Fluorescent) 03 = 35 Watts 05 = 50 Watts 07 = 70 Watts 10 = 100 Watts 5) Ballast Circuit P = Reactor Type H = High Reactance 6) Supply Voltage 12 = 120 Volts 27 = 277 Volts (Fluorescent) 7) Optics and Guards G = Glass Globe, Cat. No. VGL15 GGL = Glass Globe with Polymeric Guard R1 = Glass Refractor (IES Type I) without Guard R1P = Glass Refractor (IES Type I) with Polymeric Guard R3 = Glass Refractor (IES Type III) without Guard R3P = Glass Refractor (IES Type III) with Polymeric Guard R5 = Glass Refractor (IES Type V) without Guard R5P = Glass Refractor (IES Type V) with Polymeric Guard TB = Tempered Globe Only TGL = Tempered Globe and Polymeric Guard GCG = Green Glass Globe 8) Outlet Box Mounting Style P2 = 3/4'' Cone Pendant C2 = 3/4'' Ceiling (1 hub) C22 = 3/4'' Ceiling (2 hubs) 9) Special Options - Suffix Letter-Modification F = Fuse Kit (Not Marine Rated) 10) CSA *See General Information Page 5 for Note Regarding Glass Globes and Refractors. ** See page 9 for T-Code Ratings 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 31

Hazlux Polymeric Fixtures POLYMERIC FIXTURE COMPONENTS Hazlite M1 UL 1598 UL 1572, Suitable for Wet Locations UL 844, Class 1, ivision 2 Hazardous Locations UL 1598 Marine NEMA 4X* 9-100 Watts OUTLET BOXES esigned for all Hazlite M1 Ballasts Housings. MOUNTING STYLE Rigid Pendant Cone CATALOG NO. CONUIT HUB SIZE WT. EA. (Lbs.) ST. PKG. VPA2 3/4'' 1.3 5 LAMP (Fluorescent) CATALOG NO. CONUIT HUB SIZE WT. EA. (Lbs.) ST. PKG. VPL9 1/4 10 PL13 1/4 10 Ceiling Mount VPC2 VPC22 (FEE THROUGH) 3/4'' 1.9 5 GLOBES OR REFRACTORS CATALOG NO. ESCRIPTION WEIGHT EACH (Lbs.) VGL15 Prismatic Glass 150 Watts Max. 2.8 VGT15 Heat-Resistant Prismatic Glass 2.8 VGL15P Polycarbonate Plastic Globe 1.0 VGL15R1 IES Type I Refractor Globe 3.0 VGL15R3 IES Type III Refractor Globe 3.0 VGL15R5 IES Type V Refractor Globe 3.0 VR22CBL Low Bay Refractor with 5.0 Plastic Lens (Not UL Listed) GUARS CATALOG NO. ESCRIPTION WEIGHT EACH (Lbs.) VGU15P Polymeric For Use With Glass Globes or Refractors.3 REFLECTORS CATALOG NO. ESCRIPTION WEIGHT EACH (Lbs.) VR15P Standard ome Fiber Glass Reinforced Polyester 2.4 VRA15P 30 Angle Reflector Fiber Glass Reinforced Polyester 2.3 Refer to NEC 501-9. (b)(2) For Use of Guard in Hazardous Locations. Factory Stock See General Information Page 5 for Note Regarding Glass Globes and Refractors. * 32 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Polymeric Fixtures POLYMERIC FIXTURE COMPONENTS Hazlite M1 UL 1598 Suitable for Wet Locations UL 844, Class 1, ivision 2 Hazardous** Locations UL 1598 Marine* NEMA 4X* 9-100 Watts EXIT SIGN WEIGHT EACH CATALOG NO. ST. PKG. COLOR (Lbs.) VRE22.5 1 Red VGE22.5 1 Green Hazlux BALLAST HOUSINGS HIGH PRESSURE SOIUM High Power Factor-Reactor Type Ballast (Min. P.F. 90%) WATTAGE VOLTAGE WEIGHT EACH (Lbs.) ST. PKG. 35 120 4.8 PSM03P12 1 50 120 5.3 PSM05P12 1 70 120 5.5 PSM07P12 1 100 120 6.0 PSM10P12 1 BALLAST HOUSINGS METAL HALIE High Power Factor-Reactor Type WATTAGE VOLTAGE WEIGHT EACH (Lbs.) ST. PKG. 70 120 6.8 PHM07H12 1 100 120 7.0 PHM10H12 1 BALLAST HOUSING AN GLOBE FLUORESCENT Includes Globe and Lamp(s) shipped assembled to tank. WATTAGE VOLTAGE For voltages other than 120 volts, refer to Page 19. Consult factory for prices. * Factory Stock See General Information Page 5 for Note Regarding Glass Globes and Refractors. * WEIGHT EACH (Lbs.) ST. PKG. 9 120 7.6 PFB09P120G 1 13 120 7.6 PFB13P120G 1 18 120 10.0 PFB18P120G 1 26 120 10.0 PFB26P120G 1 ** See page 9 for T-Code Ratings 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 33

Hazlux Polymeric Fixtures POLYMERIC HIGH PRESSURE SOIUM WITH GLOBE AN GUAR Hazlite M1 35-100 Watts UL 1598 Suitable for Wet Locations UL 844, Class 1, ivision 2 Hazardous** Locations UL 1598 Marine* NEMA 4X* MOUNTING STYLE LAMP WATTS CONUIT SIZE (Inches) 120 Volt WT. EACH (Lbs.) Ballast Housing CONSISTS OF: Outlet Box Globe Guard Rigid Pendant Cone 35 3/4 PSM03P120-GGL-P2 9.6 PSM03P12 VPA2 VGL15 VGU15P 50 3/4 PSM05P120-GGL-P2 10.1 PSM05P12 VPA2 VGL15 VGU15P 70 3/4 PSM07P120-TGL-P2 10.5 PSM07P12 VPA2 VGT15 VGU15P 100 3/4 PSM10P120-TGL-P2 10.8 PSM10P12 VPA2 VGT15 VGU15P Ceiling Mount 35 3/4 PSM03P120-GGL-C2 10.2 PSM03P12 VPC2 VGL15 VGU15P 50 3/4 PSM05P120-GGL-C2 10.7 PSM05P12 VPC2 VGL15 VGU15P 70 3/4 PSM07P120-TGL-C2 10.9 PSM07P12 VPC2 VGT15 VGU15P 100 3/4 PSM10P120-TGL-C2 11.4 PSM10P12 VPC2 VGT15 VGU15P Standard ome Reflector Angle Reflector GUAR: If a guard is not required, delete L from the Catalog No. VR15P Catalog No. VRA15P Catalog Number. All fixtures are designed for medium base lamps, with the lamp mounted in the base-up position (lamps are NOT furnished with fixture). Verify Hazardous Location Certification with your requirements on General Information Page 5. See General Information Page 5 for Note Regarding Glass Globes and Refractors. * ** See page 9 for T-Code Ratings 34 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Polymeric Fixtures POLYMERIC HIGH PRESSURE SOIUM WITH REFRACTOR AN GUAR (TYPE V REFRACTOR) Hazlite M1 35-100 Watts UL 1598 Suitable for Wet Locations UL 844, Class 1, ivision 2 Hazardous** Locations UL 1598 Marine* NEMA 4X* MOUNTING STYLE LAMP WATTS CONUIT SIZE (Inches) 120 Volt WT. EACH (Lbs.) Ballast Housing CONSISTS OF: Outlet Box Refractor Guard Rigid Pendant Cone 35 3/4 PSM03P120-R5P-P2 9.8 PSM03P12 VPA2 VGL15R5 VGU15P 50 3/4 PSM05P120-R5P-P2 10.3 PSM05P12 VPA2 VGL15R5 VGU15P Hazlux 70 3/4 PSM07P120-R5P-P2 10.5 PSM07P12 VPA2 VGL15R5 VGU15P 100 3/4 PSM10P120-R5P-P2 11.0 PSM10P12 VPA2 VGL15R5 VGU15P Ceiling Mount 35 3/4 PSM03P120-R5P-C2 10.4 PSM03P12 VPC2 VGL15R5 VGU15P 50 3/4 PSM05P120-R5P-C2 10.9 PSM05P12 VPC2 VGL15R5 VGU15P 70 3/4 PSM07P120-R5P-C2 11.1 PSM07P12 VPC2 VGL15R5 VGU15P 100 3/4 PSM10P120-R5P-C2 11.6 PSM10P12 VPC2 VGL15R5 VGU15P GUAR: If a guard is not required, delete P from the Catalog Number. Catalog Number is for a Type V Refractor. Refer to General Information Page 22 for Type I or III Refractor Catalog Numbers. All fixtures are designed for medium base lamps, with the lamp mounted in the base-up position (lamps are NOT furnished with fixture). Verify Hazardous Location Certification with your requirements on General Information Page 5. See General Information Page 5 for Note Regarding Glass Globes and Refractors. * ** See page 9 for T-Code Ratings 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 35

Hazlux Polymeric Fixtures POLYMERIC METAL HALIE WITH GLOBE AN GUAR Hazlite M1 70-100 Watts UL 1598 Suitable for Wet Locations UL 844, Class 1, ivision 2 Hazardous** Locations UL 1598 Marine* NEMA 4X* MOUNTING STYLE LAMP WATTS CONUIT SIZE (Inches) 120 Volt WT. EACH (Lbs.) Ballast Housing CONSISTS OF: Outlet Box Globe Guard Rigid Pendant Cone 70 3/4 PHM07H120-TGL-P2 11.6 PHM07H12 VPA2 VGT15 VGU15P 100 3/4 PHM10H120-TGL-P2 11.8 PHM10H12 VPA2 VGT15 VGU15P Ceiling Mount 70 3/4 PHM07H120-TGL-C2 12.2 PHM07H12 VPC2 VGT15 VGU15P 100 3/4 PHM10H120-TGL-C2 12.4 PHM10H12 VPC2 VGT15 VGU15P All fixtures are designed for medium base lamps, with the lamp mounted in the base-up position (lamps are NOT furnished with fixture). Verify Hazardous Location Certification with your requirements on General Information Page 5. See General Information Page 5 for Note Regarding Glass Globes and Refractors. * POLYMERIC METAL HALIE WITH REFRACTOR AN GUAR (TYPE V REFRACTOR) Hazlite M1 70-100 Watts UL 1572, Suitable for Wet Locations UL 844, Class 1, ivision 2 Hazardous Locations UL 595 Marine* NEMA 4X* MOUNTING STYLE LAMP WATTS CONUIT SIZE (Inches) 120 Volt WT. EACH (Lbs.) Ballast Housing CONSISTS OF: Outlet Box Refractor Guard Rigid Pendant Cone 70 3/4 PHM07H120-R5P-P2 11.6 PHM07H12 VPA2 VGL15R5 VGU15P 100 3/4 PHM10H120-R5P-P2 11.8 PHM10H12 VPA2 VGL15R5 VGU15P Ceiling Mount 70 3/4 PHM07H120-R5P-C2 12.2 PHM07H12 VPC2 VGL15R5 VGU15P 100 3/4 PHM10H120-R5P-C2 12.4 PHM10H12 VPC2 VGL15R5 VGU15P Catalog Number is for a Type V Refractor. Refer to General Information Page 19 for Type I or III Refractor Catalog Numbers. All fixtures are designed for medium base lamps, with the lamp mounted in the base-up position (lamps are NOT furnished with fixture). Verify Hazardous Location Certification with your requirements on General Information Page 5. See General Information Page 5 for Note Regarding Glass Globes and Refractors. * ** See page 9 for T-Code Ratings 36 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Polymeric Fixtures POLYMERIC FLUORESCENT WITH GLOBE AN GUAR LAMPS INCLUE Hazlite M1 9-26 Watts UL 1598 Suitable for Wet Locations UL 844, Class 1, ivision 2 Hazardous** Locations UL 1598 Marine* NEMA 4X* FLUORESCENT 9-26 WATTS MOUNTING STYLE Rigid Pendant Cone LAMP WATTS CONUIT SIZE (Inches) 120 Volt WT. EACH (Lbs.) Ballast Housing, Globe & Lamp(s) CONSISTS OF: Outlet Box Guard 9 3/4 PFB09P120-GGL-P2 9.6 PFB09P120G VPA2 VGU15P Hazlux 13 3/4 PFB13P120-GGL-P2 9.5 PFB13P120G VPA2 VGU15P 18 3/4 PFB18P120-GGL-P2 10.0 PFB18P120G VPA2 VGU15P 26 3/4 PFB26P120-GGL-P2 9.5 PFB26P120G VPA2 VGU15P Ceiling Mount 9 3/4 PFB09P120-GGL-C2 10.2 PFB09P120G VPC2 VGU15P 13 3/4 PFB13P120-GGL-C2 9.5 PFB13P120G VPC2 VGU15P 18 3/4 PFB18P120-GGL-C2 10.6 PFB18P120G VPC2 VGU15P 26 3/4 PFB26P120-GGL-C2 10.5 PFB26P120G VPC2 VGU15P Standard ome Reflectors Angle Reflectors GUAR: If a guard is not required, delete GL from the Catalog No. VR15P Catalog No. VRA15P Catalog Number. Fluorescent fixtures use PL type lamps (one or two lamps included). See General Information Page 5 for Note Regarding Glass Globes and Refractors. * ** See page 9 for T-Code Ratings 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 37

Hazlux Polymeric Fixtures Hazlite M1 imensional rawings CONE PENANT MOUNT WITH ANGLE REFLECTOR 8 5/8'' (219) 7 7/8'' (200) CONE PENANT MOUNT WITH OME REFLECTOR 8 5/8'' (219) 7 7/8'' (200) 9 3/4'' (248) 6 11/16'' (170) 4 7/8'' (124) 6 11/16'' (170) 15 7/8'' (403) 15'' (381) 9 5/8'' (244) ia. B.C. 8 5/8'' (219) 8 5/8'' (219) CONE PENANT MOUNT 7 7/8'' (200) CEILING MOUNT 6 7/8'' (174) 6 1/2'' (165) 6 1/2'' (165) 9 5/8'' (244) ia. B.C. 8 5/8'' (219) 9 5/8'' (244) ia. B.C. 8 5/8'' (219) CEILING MOUNT WITH OME REFLECTOR 6 7/8'' (174) CEILING MOUNT WITH ANGLE REFLECTOR 6 7/8'' (174) 4 7/8'' (124) 6 11/16'' (170) 9 3/4'' (248) 6 11/16'' (170) 15'' (381) 15 7/8'' (403) 38 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Enclosed & Gasketed Fixtures for Adverse, Wet & Marine ENCLOSE and GASKETE FIXTURES for AVERSE, WET and MARINE LOCATIONS* CONTENTS PAGE Hazlux 2...41 HI, Mogul Base; 50-400W Hazlux Hazlite M2...57 HI, Medium Base; 9-150W Compact Fluorescent Incandescent *Check individual product listings for specific suitabilities. 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 39

Hazlux Enclosed & Gasketed Fixtures for Adverse, Wet & Marine HAZLUX RAPI SERVICE OPTIONS Hazlux 3 50-400 Watts UL 1598 Enclosed and Gasketed Suitable for Wet Locations UL 595 Marine* NEMA 4X* Hazlux Rapid Service Program Why put off to tomorrow what we can ship today? Select any top hat and one light - and you re done! Thomas & Betts is pleased to announce it s new Rapid Service Program for Hazlux Lighting Fixtures. For smaller quantities, we now stock complete, assembled fixtures (less a mounting hat). This includes the lamp, installed! For customers in need of immediate service, Thomas & Betts will be able to ship these fixtures right from our distribution center. Simply order a fixture and a top hat from those listed on the back. These select Hazlux fixtures will come pre-wired, with lamp installed, with no added cost to you! If you need an immediate solution for a smaller project, or you need help getting a larger project started, contact your Thomas & Betts Representative for more details about our Rapid Service Program for Hazlux Lighting Fixtures. Put down the calendar and give us a call. We re ready, so you won t have to wait! VP2 VF2 VA2 VC2 VB2 VS5 VL5 H017C04R-R5P-E H017C040-TGL-E H025C040-TGL-E HP25C040-TGL-E S010H040-TGL-E S010H040-TGL-E Hazlux Fixture Ordering Information escription Cat. No. f" Bracket Mount VB2 1d" 25 Stanchion VS5 1d" Straight Stanchion VL5 f" Cone Pendant VA2 f" Ceiling Mount VC2 f" Pendant Mount VP2 f" Flex Pendant Mount VF2-HZ escription Cat. No. 175 Watt Metal Halide with globe, guard and lamp installed - Type V Refractor H017C04R-R5P-E 175 Watt Metal Halide with globe, guard and lamp installed H017C040-TGL-E 250 Watt Metal Halide with globe, guard and lamp installed H025C040-TGL-E 250 Watt Pulse Start Metal Halide with globe, guard and lamp installed HP25C040-TGL-E 100 Watt High Pressure Sodium with globe, guard and lamp installed S010H040-TGL-E 150 Watt High Pressure Sodium with globe, guard and lamp installed S015H040-TGL-E 40 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Enclosed & Gasketed Fixtures for Adverse, Wet & Marine CATALOG NUMBERING SYSTEM Hazlux 2 UL 1598 Enclosed and Gasketed Suitable for Wet Locations UL 595 Marine* NEMA 4X* 50-400 Watts Catalog Numbering System V S 0 15 H 04 0 - TGL - P2 E1 F N 1 2 3 4 5 6 7 8 9 11 12 13 Hazlux 1 Hazlux Fixture Series V = Hazlux 2 HI Fixture UL 1598 Marine Locations Wet Locations NEMA 4X, IP66 2 Lamp Type S = High Pressure Sodium H = Metal Halide M = Mercury Vapor 3 Starter Circuit/Quartz Options 0 = Standard Fixture Q = Quartz Auxiliary Option R = Instant Restart J = Auto Shutoff Starter P = Pulse Start 4 Lamp Wattage 05 = 50 Watts 07 = 70 Watts 10 = 100 Watts 15 = 150 Watts 17 = 175 Watts 20 = 200 Watts 25 = 250 Watts 32 = 320 Watts 35 = 350 Watts 40 = 400 Watts 5 Ballast Circuit H = High Reactance C = Constant Wattage Autotransformer (All ballasts high power factor.) 6 Voltage/Frequency 03 = 120/277V, 60Hz 04 = 120/208/240/277V, 60Hz 09 = 120/277/347V, 60Hz (CSA) 12 = 120V, 60Hz 27 = 277V, 60Hz 48 = 480V, 60Hz 225 = 220V, 50Hz 245 = 240V, 50Hz 7 8 Ballast Housing Style 0 = Standard Housing (150W HPS, 250W MH, MV max.) R = Refractor Globe Housing (150W HPS, 250W MH, MV max.) L = Large Housing (200-400W HPS; 400W MH, MV) S = Standard Housing w/stainless Steel Inserts I = Refractor Globe Housing w/stainless Steel Inserts M = Large Housing w/stainless Steel Inserts Optical Assembly Options For Std. Housing Fixtures (5-1/2 Thread) TG = Thermal Shock Resist. Globe TGL = TG with Polymeric Guard SG = Tuffskin Coated Globe SGL= SG with Polymeric Guard R2 = 12 Glass Refractor, Type II R5 = 12 Glass Refractor, Type V R2G= R2 with Wire Guard R5G= R5 with Wire Guard For Refr. Globe Housing Fixtures (7-3/4 Thread) R1 = 7 3 4 Refractor Globe, Type I R3 = 7 3 4 Refractor Globe, Type III R5 = 7 3 4 Refractor Globe, Type V R1P = R1 with Polymeric Guard R3P = R3 with Polymeric Guard R5P = R5 with Polymeric Guard TG = 7 3 4 Thermal Shock Res. Globe TGP= TG with Polymeric Guard For Large Housing Fixtures (7-3/4'' Thread) TG = Thermal Shock Resist. Globe TGC= TG with Cast Alum. Guard SG = Tuffskin Coated Globe SGC= SG with Cast Alum. Guard R2 = 12'' Glass Refractor, Type II R5 = 12 Glass Refractor, Type V R2G= R2 with Steel Guard R5G= R5 with Steel Guard RCB= Enclosed High Bay Reflector RCG= RCB with Steel Wire Guard 9 10 11 12 13 14 Mounting Style A2 = 3 4 Cone Top Pendant A3 = 1 Cone Top Pendant B2 = 3 4 Wall Mount B3 = 1 Wall Mount C2 = 3 4 Ceiling Mount C3 = 1 Ceiling Mount F2 = 3 4 Flexible Pendant F3 = 1 Flexible Pendant HV1 = HazVertor Ring - CI, 2 HV2 = HazVertor Ring - CII, 1 L4 = 1 1 4 Straight Stanchion L5 = 1 1 2 Straight Stanchion P2 = 3 4 Rigid Pendant P3 = 1 Rigid Pendant S4 = 1 1 4 25 Angle Stanchion S5 = 1 1 2 25 Angle Stanchion Special FInish Option T = HazCote Custom Corrosion Coating UNIPAK Packaging Options E = UNIPAK with Clear Lamp E1 = UNIPAK, Clear Lamp, ome Reflector E2 = UNIPAK, Clear Lamp, Angle Reflector = UNIPAK with ual Arc Lamp 1 = UNIPAK, ual Arc Lamp, ome Reflector 2 = UNIPAK, ual Arc Lamp, Angle Reflector U = UNIPAK, with No Lamp (Not Marine Listed) Fusing Options F = Single Fuse Block with Fuse FF = ouble Fuse Block with Fuse NEMA Lamp Wattage ecal N = NEMA Lamp Wattage ecal on Housing CSA Certification C = CSA Nameplate (consult factory) * See General Information Page 5 for Note Regarding Glass, Globes & Refractors. 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 41

Hazlux Enclosed & Gasketed Fixtures for Adverse, Wet & Marine FIXTURE COMPONENTS Hazlux 2 UL 1598 Enclosed and Gasketed Suitable for Wet Locations UL 595 Marine* NEMA 4X* 50-400 Watts HV1 VP2 VF2 VA2 VC2 VB2 VS5 VL5 H3 STANAR TANK H3 "R" TANK H3 "L" TANK VGT22 VRF22C5 VGT31S VGL31R5 VRF31C5 VR31CB VGT31 VGU22P VGU22 VGR48 VGU31RP VGU31R VGR48 VGR64 VGU31 VR22P VRA22P VR31P VRA31P VR31 VR31P VRA31P Hazlux 2 Options The options listed below plus many more are available with Hazlux 2 fixtures. Refer to the Catalog Numbering System section and Ordering Information pages of this catalog for ordering details. Instant Restart (50-150W HPS) Allows high pressure sodium lamp to be immediately restarted after a momentary power outage. Auxiliary Quartz Circuit - All Fixture provided with 120 volt 100 watt quartz lamp circuit. Quartz lamp will operate during HI warm-up period, or when HI lamp cools down before restarting. NEMA Lamp Wattage ecal - All Adhesive backed lamp wattage decal is provided on ballast housing exterior to clearly indicate wattage for relamping and maintenance. Auto Shutoff Option (50-150W HPS) Auto shutoff device prevents starter failure by disabling the starter circuit in case of cycling or defective HPS lamp. (Not for use with instant restart option.) 50 Hertz Ballasts (Most Hazlux 2 Fixtures) 50 hertz ballasts in a variety of voltages can be furnished for international voltage systems. Tuffskin Coated Glass Globes (All Globes) Tuffskin silicone coating contains glass particles in case of breakage; prevents glass from contaminating process areas. HazCote Custom Corrosion Resistant Coating (All) Custom chemical coating provides even higher degree of corrosion protection for cast aluminum parts. For use in highly corrosive environments. ual Arc Tube Lamps (HPS) Provide standby/immediate restart capabilities. Stainless Steel Inserts (All) Stainless steel inserts for guard screws and ballast housing closure screw eliminate possiblility of galvanic corrosion between stainless steel screws and aluminum parts. UNIPAK Packaging (All) UNIPAK packaging means that fixtures are completely assembled with lamp and foamed in one carton. Saves labor, handling, storage, and reduces total installed cost per fixture. See UNI- PAK section of this brochure. HazVertor Adapter Ring UL Listed adapter ring enables quick, easy, UL listed retrofit of Crouse-Hinds VMV, LMV, and MV series Champ fixtures. See HazVertor section of this brochure. Crouse-Hinds and Champ are registered trademarks of Cooper Industries, Inc. 42 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Enclosed & Gasketed Fixtures for Adverse, Wet & Marine UNIPAK, HazVertor, Other Options Hazlux 2 UL 1598 Enclosed and Gasketed Suitable for Wet Locations UL 595 Marine* NEMA 4X* 50-400 Watts UNIPAK Packaging Hazlux 2 fixtures ordered with the UNIPAK packaging option will be completely assembled with lamp (and with mounting cover and/or reflector, if specified) and shipped in one carton. Each fixture assembly is foamed in place in the carton to insure zero transit damage. Receiving, handling, storing, identification, assembly, and component matching are all made easier by this common sense approach to manufacturing and shipping. Hazlux Use the Catalog Numbering codes (Position #11) to add UNIPAK with lamp packaging to any make-to-order Hazlux 2 assembly, or refer to the table below to order the most commonly used Hazlux 2 UNIPAK assemblies. Benefits of UNIPAK Packaging: Fewer cartons to receive. Fewer cartons to store. Reduced jobsite material handling costs Lower installation labor costs. No chance of Lamp/Ballast mismatch in field. No waiting around for fixtures. Hazlux 2 UNIPAK with Lamp Fixture Assemblies (Order Mounting Covers, Reflectors Separately) Hazlux 2 UNIPAK, escription 70W HPS with Globe, Guard, Lamp 100W HPS with Globe, Guard, Lamp 150W HPS with Globe, Guard, Lamp 175W MH with Globe, Guard, Lamp 150W HPS with Type V Refractor Globe, Guard, Lamp Catalog No. VS007H040-TGL-E VS010H040-TGL-E VS015H040-TGL-E VH017C040-TGL-E VS015H04R-R5P-E HazVertor Adapter Ring The HazVertor Ring is a UL listed adapter ring which gives you the freedom to replace Crouse-Hinds VMV, LMV, and MV series Champ lighting fixtures with Hazlux 2 fixtures without removing the Crouse-Hinds mounting top hat from the conduit system. Just Look at the Advantages: Increase energy efficiency and lumen output by upgrading from mercury vapor to metal halide or high pressure sodium. Utilize Hazlux threaded glass refractors for improved light distribution. Improved photometric performance in many cases. Easy to Order. Easy to Install. UL Listed. For Use with ANY Hazlux 2 Fixture. Crouse-Hinds and Champ are registered trademarks of Cooper Industries, Inc. 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 43

Hazlux Enclosed & Gasketed Fixtures for Adverse, Wet & Marine STANAR BALLAST HOUSING Hazlux 2 UL 1598 Enclosed and Gasketed Suitable for Wet Locations UL 595 Marine* NEMA 4X* WITH GLOBE AN GUAR 50-400 Watts Rigid Pendant Catalog Number Flex. Pendant Catalog Number Cone Pendant Catalog Number Ceiling Catalog Number Wall Catalog Number Lamp Watts Hub Size 50 3/4 VS005H120-GGL-P2 VS005H120-GGL-F2 VS005H120-GGL-A2 VS005H120-GGL-C2 VS005H120-GGL-B2 1 VS005H120-GGL-P3 VS005H120-GGL-F3 VS005H120-GGL-A3 VS005H120-GGL-C3 VS005H120-GGL-B3 High Pressure Sodium 70 100 3/4 VS007H040-TGL-P2 VS007H040-TGL-F2 VS007H040-TGL-A2 VS007H040-TGL-C2 VS007H040-TGL-B2 1 VS007H040-TGL-P3 VS007H040-TGL-F3 VS007H040-TGL-A3 VS007H040-TGL-C3 VS007H040-TGL-B3 3/4 VS010H040-TGL-P2 VS010H040-TGL-F2 VS010H040-TGL-A2 VS010H040-TGL-C2 VS010H040-TGL-B2 1 VS010H040-TGL-P3 VS010H040-TGL-F3 VS010H040-TGL-A3 VS010H040-TGL-C3 VS010H040-TGL-B3 150 3/4 VS015H040-TGL-P2 VS015H040-TGL-F2 VS015H040-TGL-A2 VS015H040-TGL-C2 VS015H040-TGL-B2 1 VS015H040-TGL-P3 VS015H040-TGL-F3 VS015H040-TGL-A3 VS015H040-TGL-C3 VS015H040-TGL-B3 70 3/4 VH007H030-TGL-P2 VH007H030-TGL-F2 VH007H030-TGL-A2 VH007H030-TGL-C2 VH007H030-TGL-B2 1 VH007H030-TGL-P3 VH007H030-TGL-F3 VH007H030-TGL-A3 VH007H030-TGL-C3 VH007H030-TGL-B3 Metal Halide 100 175 3/4 VH010H040-TGL-P2 VH010H040-TGL-F2 VH010H040-TGL-A2 VH010H040-TGL-C2 VH010H040-TGL-B2 1 VH010H040-TGL-P3 VH010H040-TGL-F3 VH010H040-TGL-A3 VH010H040-TGL-C3 VH010H040-TGL-B3 3/4 VH017C040-TGL-P2 VH017C040-TGL-F2 VH017C040-TGL-A2 VH017C040-TGL-C2 VH017C040-TGL-B2 1 VH017C040-TGL-P3 VH017C040-TGL-F3 VH017C040-TGL-A3 VH017C040-TGL-C3 VH017C040-TGL-B3 250 3/4 VH025C040-TGL-P2 VH025C040-TGL-F2 VH025C040-TGL-A2 VH025C040-TGL-C2 VH025C040-TGL-B2 1 VH025C040-TGL-P3 VH025C040-TGL-F3 VH025C040-TGL-A3 VH025C040-TGL-C3 VH025C040-TGL-B3 Mercury Vapor 100 175 3/4 VM010H040-TGL-P2 VM010H040-TGL-F2 VM010H040-TGL-A2 VM010H040-TGL-C2 VM010H040-TGL-B2 1 VM010H040-TGL-P3 VM010H040-TGL-F3 VM010H040-TGL-A3 VM010H040-TGL-C3 VM010H040-TGL-B3 3/4 VM017C040-TGL-P2 VM017C040-TGL-F2 VM017C040-TGL-A2 VM017C040-TGL-C2 VM017C040-TGL-B2 1 VM017C040-TGL-P3 VM017C040-TGL-F3 VM017C040-TGL-A3 VM017C040-TGL-C3 VM017C040-TGL-B3 imensions: 13 3 /8" (340) 250 13 3 /8" (340) 3/4 VM025C040-TGL-P2 VM025C040-TGL-F2 VM025C040-TGL-A2 VM025C040-TGL-C2 VM025C040-TGL-B2 1 VM025C040-TGL-P3 VM025C040-TGL-F3 VM025C040-TGL-A3 VM025C040-TGL-C3 VM025C040-TGL-B3 13 3 /8" (340) 13 3 /8" (340) 14 7 /8" (378) 13 3 /4" (349) 13 3 /4" (349) 18 11 /32" (466) 14 1 /2" (368) 16 3 /4" (425) Rigid Flexible Cone Pendant Pendant Pendant Ceiling Wall 44 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Enclosed & Gasketed Fixtures for Adverse, Wet & Marine STANAR BALLAST HOUSING Hazlux 2 UL 1598 Enclosed and Gasketed Suitable for Wet Locations UL 595 Marine* NEMA 4X* WITH GLOBE AN GUAR 50-400 Watts Lamp Watts Hub Size 25 Stanchion Catalog Number Straight Stanchion Catalog Number HazVertor Ring Catalog Number Ordering Notes: 1. All fixtures (except 50W HPS and 70W MH) are shown with multi-tap ballast (120, 208, 240, 277V). To order 480V or any other dedicated voltage, substitute desired voltage code from Catalog Numbering System on page 41. Example: For 100W HPS, 480V, substitute H48 for H04 - VS010H480-TGL- P2. Hazlux High Pressure Sodium 50 70 100 1-1/4 VS005H120-GGL-S4 VS005H120-GGL-L4 VS005H120-GGL-HV1 1-1/2 VS005H120-GGL-S5 VS005H120-GGL-L5 1-1/4 VS007H040-TGL-S4 VS007H040-TGL-L4 1-1/2 VS007H040-TGL-S5 VS007H040-TGL-L5 1-1/4 VS010H040-TGL-S4 VS010H040-TGL-L4 1-1/2 VS010H040-TGL-S5 VS010H040-TGL-L5 VS007H040-TGL-HV1 VS010H040-TGL-HV1 2. All fixtures are for use with mogul base lamps. Lamps are not included unless UNIPAK with Lamp packaging is specified. See Note 43. 3. To order Hazlux 2 fixtures with UNIPAK with Lamp packaging, add E to the end of the catalog number. Example: VH017C040- TGL-S5E. See page 43 for details. Metal Halide 150 70 100 175 1-1/4 VS015H040-TGL-S4 VS015H040-TGL-L4 1-1/2 VS015H040-TGL-S5 VS015H040-TGL-L5 1-1/4 VH007H030-TGL-S4 VH007H030-TGL-L4 1-1/2 VH007H030-TGL-S5 VH007H030-TGL-L5 1-1/4 VH010H040-TGL-S4 VH010H040-TGL-L4 1-1/2 VH010H040-TGL-S5 VH010H040-TGL-L5 1-1/4 VH017C040-TGL-S4 VH017C040-TGL-L4 1-1/2 VH017C040-TGL-S5` VH017C040-TGL-L5 VS015H040-TGL-HV1 VH007H030-TGL-HV1 VH010H040-TGL-HV1 VH017C040-TGL-HV1 4. Refer to Note Regarding Glass Globes and Refractors on page 5 for hose-down information. 5. Fixtures are shown with guard. To order fixture without guard, change TGL to TG. Example: VH017C040-TG-C2. 6. Refer to page 41 for Hazlux 2 Options, and page 56 for Hazlux 2 Accessories and Parts. 250 1-1/4 VH025C040-TGL-S4 VH025C040-TGL-L4 1-1/2 VH025C040-TGL-S5 VH025C040-TGL-L5 VH025C040-TGL-HV1 Mercury Vapor 100 175 1-1/4 VM010H040-TGL-S4 VM010H040-TGL-L4 VM010H040-TGL-HV1 1-1/2 VM010H040-TGL-S5 VM010H040-TGL-L5 1-1/4 VM017C040-TGL-S4 VM017C040-TGL-L4 VM017C040-TGL-HV1 1-1/2 VM017C040-TGL-S5 VM017C040-TGL-L5 250 1-1/4 VM025C040-TGL-S4 VM025C040-TGL-L4 VM025C040-TGL-HV1 1-1/2 VM025C040-TGL-S5 VM025C040-TGL-L5 imensions: 16 1 /8" 15 3 /4" 13 3 /8" (410) (400) (340) 15 3 /16" (386) 15 3 /16" (386) 14 3 /4" (375) 25 Straight HazVertor Stanchion Stanchion Ring 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 45

Hazlux Enclosed & Gasketed Fixtures for Adverse, Wet & Marine STANAR BALLAST HOUSING WITH 12'' REFRACTOR AN GUAR Hazlux 2 50-400 Watts UL 1598 Enclosed and Gasketed Suitable for Wet Locations UL 595 Marine* NEMA 4X* Rigid Pendant Catalog Number Flex. Pendant Catalog Number Cone Pendant Catalog Number Ceiling Catalog Number Wall Catalog Number Lamp Watts Hub Size 50 3/4 VS005H120-R5G-P2 VS005H120-R5G-F2 VS005H120-R5G-A2 VS005H120-R5G-C2 VS005H120-R5G-B2 1 VS005H120-R5G-P3 VS005H120-R5G-F3 VS005H120-R5G-A3 VS005H120-R5G-C3 VS005H120-R5G-B3 High Pressure Sodium 70 100 3/4 VS007H040-R5G-P2 VS007H040-R5G-F2 VS007H040-R5G-A2 VS007H040-R5G-C2 VS007H040-R5G-B2 1 VS007H040-R5G-P3 VS007H040-R5G-F3 VS007H040-R5G-A3 VS007H040-R5G-C3 VS007H040-R5G-B3 3/4 VS010H040-R5G-P2 VS010H040-R5G-F2 VS010H040-R5G-A2 VS010H040-R5G-C2 VS010H040-R5G-B2 1 VS010H040-R5G-P3 VS010H040-R5G-F3 VS010H040-R5G-A3 VS010H040-R5G-C3 VS010H040-R5G-B3 150 3/4 VS015H040-R5G-P2 VS015H040-R5G-F2 VS015H040-R5G-A2 VS015H040-R5G-C2 VS015H040-R5G-B2 1 VS015H040-R5G-P3 VS015H040-R5G-F3 VS015H040-R5G-A3 VS015H040-R5G-C3 VS015H040-R5G-B3 70 3/4 VH007H030-R5G-P2 VH007H030-R5G-F2 VH007H030-R5G-A2 VH007H030-R5G-C2 VH007H030-R5G-B2 1 VH007H030-R5G-P3 VH007H030-R5G-F3 VH007H030-R5G-A3 VH007H030-R5G-C3 VH007H030-R5G-B3 Metal Halide 100 175 3/4 VH010H040-R5G-P2 VH010H040-R5G-F2 VH010H040-R5G-A2 VH010H040-R5G-C2 VH010H040-R5G-B2 1 VH010H040-R5G-P3 VH010H040-R5G-F3 VH010H040-R5G-A3 VH010H040-R5G-C3 VH010H040-R5G-B3 3/4 VH017C040-R5G-P2 VH017C040-R5G-F2 VH017C040-R5G-A2 VH017C040-R5G-C2 VH017C040-R5G-B2 1 VH017C040-R5G-P3 VH017C040-R5G-F3 VH017C040-R5G-A3 VH017C040-R5G-C3 VH017C040-R5G-B3 250 3/4 VH025C040-R5G-P2 VH025C040-R5G-F2 VH025C040-R5G-A2 VH025C040-R5G-C2 VH025C040-R5G-B2 1 VH025C040-R5G-P3 VH025C040-R5G-F3 VH025C040-R5G-A3 VH025C040-R5G-C3 VH025C040-R5G-B3 Mercury Vapor 100 175 3/4 VM010H040-R5G-P2 VM010H040-R5G-F2 VM010H040-R5G-A2 VM010H040-R5G-C2 VM010H040-R5G-B2 1 VM010H040-R5G-P3 VM010H040-R5G-F3 VM010H040-R5G-A3 VM010H040-R5G-C3 VM010H040-R5G-B3 3/4 VM017C040-R5G-P2 VM017C040-R5G-F2 VM017C040-R5G-A2 VM017C040-R5G-C2 VM017C040-R5G-B2 1 VM017C040-R5G-P3 VM017C040-R5G-F3 VM017C040-R5G-A3 VM017C040-R5G-C3 VM017C040-R5G-B3 250 3/4 VM025C040-R5G-P2 VM025C040-R5G-F2 VM025C040-R5G-A2 VM025C040-R5G-C2 VM025C040-R5G-B2 1 VM025C040-R5G-P3 VM025C040-R5G-F3 VM025C040-R5G-A3 VM025C040-R5G-C3 VM025C040-R5G-B3 imensions: 13 3 /8" (340) 13 3 /8" (340) 13 3 /8" (340) 13 3 /8" (340) 14 7 /8" (378) 16 11 /16" (424) 16 11 /16" (424) 21 1 /4" (540) 17 5 /16" (440) 19 9 /16" (497) Rigid Flexible Cone Pendant Pendant Pendant Ceiling Wall 46 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Enclosed & Gasketed Fixtures for Adverse, Wet & Marine STANAR BALLAST HOUSING WITH 12'' REFRACTOR AN GUAR Hazlux 2 50-400 Watts UL 1598 Enclosed and Gasketed Suitable for Wet Locations UL 595 Marine* NEMA 4X* Lamp Watts Hub Size 25 Stanchion Catalog Number Straight Stanchion Catalog Number HazVertor Ring Catalog Number Ordering Notes: 1. All fixtures (except 50W HPS and 70W MH) are shown with multi-tap ballast (120, 208, 240, 277V). To order 480V or any other dedicated voltage, substitute desired voltage code from Catalog Numbering System on page 41. Example: For 100W HPS, 480V, substitute H48 for H04 - VS010H480-R5G- P2. Hazlux High Pressure Sodium 50 70 100 1-1/4 VS005H120-R5G-S4 VS005H120-R5G-L4 VS005H120-R5G-HV1 1-1/2 VS005H120-R5G-S5 VS005H120-R5G-L5 1-1/4 VS007H040-R5G-S4 VS007H040-R5G-L4 VS007H040-R5G-HV1 1-1/2 VS007H040-R5G-S5 VS007H040-R5G-L5 1-1/4 VS010H040-R5G-S4 VS010H040-R5G-L4 VS010H040-R5G-HV1 1-1/2 VS010H040-R5G-S5 VS010H040-R5G-L5 2. All fixtures are for use with mogul base lamps. Lamps are not included unless UNIPAK with Lamp packaging is specified. See Note 43. 3. To order Hazlux 2 fixtures with UNIPAK with Lamp packaging, add E to the end of the catalog number. Example: VH017C040- R5G-S5E. See page 43 for details. 150 70 1-1/4 VS015H040-R5G-S4 VS015H040-R5G-L4 VS015H040-R5G-HV1 1-1/2 VS015H040-R5G-S5 VS015H040-R5G-L5 1-1/4 VH007H030-R5G-S4 VH007H030-R5G-L4 VH007H030-R5G-HV1 1-1/2 VH007H030-R5G-S5 VH007H030-R5G-L5 4. Refer to Note Regarding Glass Globes and Refractors on page 5 for hose-down information. 5. Fixtures are shown with IES Type V refractor for symmetrical light distribution. To order with IES Type II refractor, substitute R2G for R5G in catalog number. Example: VS015H040-R2G-L5. Metal Halide 100 175 1-1/4 VH010H040-R5G-S4 VH010H040-R5G-L4 VH010H040-R5G-HV1 1-1/2 VH010H040-R5G-S5 VH010H040-R5G-L5 1-1/4 VH017C040-R5G-S4 VH017C040-R5G-L4 VH017C040-R5G-HV1 1-1/2 VH017C040-R5G-S5` VH017C040-R5G-L5 6. Fixtures are shown with guard. To order fixture without guard, change R5G to R5. Example: VH017C040-R5-C2. 7. Refer to page 41 for Hazlux 2 Options, and page 56 for Hazlux 2 Accessories and Parts. 250 1-1/4 VH025C040-R5G-S4 VH025C040-R5G-L4 VH025C040-R5G-HV1 1-1/2 VH025C040-R5G-S5 VH025C040-R5G-L5 100 1-1/4 VM010H040-R5G-S4 VM010H040-R5G-L4 VM010H040-R5G-HV1 1-1/2 VM010H040-R5G-S5 VM010H040-R5G-L5 Mercury Vapor 175 1-1/4 VM017C040-R5G-S4 VM017C040-R5G-L4 VM017C040-R5G-HV1 1-1/2 VM017C040-R5G-S5 VM017C040-R5G-L5 250 1-1/4 VM025C040-R5G-S4 VM025C040-R5G-L4 VM025C040-R5G-HV1 1-1/2 VM025C040-R5G-S5 VM025C040-R5G-L5 imensions: 16 1 /8" (206) 15 3 /4" (400) 13 3 /8" (340) 18 1 /8" (460) 18 1 /8" (460) 17 9 /16" (446) 25 Straight HazVertor Stanchion Stanchion Ring 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 47

Hazlux Enclosed & Gasketed Fixtures for Adverse, Wet & Marine R-TANK BALLAST HOUSING WITH 7-3/4'' REFRACTOR AN GUAR Hazlux 2 50-250 Watts UL 1598 Enclosed and Gasketed Suitable for Wet Locations UL 595 Marine* NEMA 4X* Rigid Pendant Catalog Number Flex. Pendant Catalog Number Cone Pendant Catalog Number Ceiling Catalog Number Wall Catalog Number Lamp Watts Hub Size 50 3/4 VS005H12R-R5P-P2 VS005H12R-R5P-F2 VS005H12R-R5P-A2 VS005H12R-R5P-C2 VS005H12R-R5P-B2 1 VS005H12R-R5P-P3 VS005H12R-R5P-F3 VS005H12R-R5P-A3 VS005H12R-R5P-C3 VS005H12R-R5P-B3 High Pressure Sodium 70 100 3/4 VS007H04R-R5P-P2 VS007H04R-R5P-F2 VS007H04R-R5P-A2 VS007H04R-R5P-C2 VS007H04R-R5P-B2 1 VS007H04R-R5P-P3 VS007H04R-R5P-F3 VS007H04R-R5P-A3 VS007H04R-R5P-C3 VS007H04R-R5P-B3 3/4 VS010H04R-R5P-P2 VS010H04R-R5P-F2 VS010H04R-R5P-A2 VS010H04R-R5P-C2 VS010H04R-R5P-B2 1 VS010H04R-R5P-P3 VS010H04R-R5P-F3 VS010H04R-R5P-A3 VS010H04R-R5P-C3 VS010H04R-R5P-B3 150 3/4 VS015H04R-R5P-P2 VS015H04R-R5P-F2 VS015H04R-R5P-A2 VS015H04R-R5P-C2 VS015H04R-R5P-B2 1 VS015H04R-R5P-P3 VS015H04R-R5P-F3 VS015H04R-R5P-A3 VS015H04R-R5P-C3 VS015H04R-R5P-B3 70 3/4 VH007H03R-R5P-P2 VH007H03R-R5P-F2 VH007H03R-R5P-A2 VH007H03R-R5P-C2 VH007H03R-R5P-B2 1 VH007H03R-R5P-P3 VH007H03R-R5P-F3 VH007H03R-R5P-A3 VH007H03R-R5P-C3 VH007H03R-R5P-B3 Metal Halide 100 175 3/4 VH010H04R-R5P-P2 VH010H04R-R5P-F2 VH010H04R-R5P-A2 VH010H04R-R5P-C2 VH010H04R-R5P-B2 1 VH010H04R-R5P-P3 VH010H04R-R5P-F3 VH010H04R-R5P-A3 VH010H04R-R5P-C3 VH010H04R-R5P-B3 3/4 VH017C04R-R5P-P2 VH017C04R-R5P-F2 VH017C04R-R5P-A2 VH017C04R-R5P-C2 VH017C04R-R5P-B2 1 VH017C04R-R5P-P3 VH017C04R-R5P-F3 VH017C04R-R5P-A3 VH017C04R-R5P-C3 VH017C04R-R5P-B3 250 3/4 VH025C04R-R5P-P2 VH025C04R-R5P-F2 VH025C04R-R5P-A2 VH025C04R-R5P-C2 VH025C04R-R5P-B2 1 VH025C04R-R5P-P3 VH025C04R-R5P-F3 VH025C04R-R5P-A3 VH025C04R-R5P-C3 VH025C04R-R5P-B3 Mercury Vapor 100 175 3/4 VM010H04R-R5P-P2 VM010H04R-R5P-F2 VM010H04R-R5P-A2 VM010H04R-R5P-C2 VM010H04R-R5P-B2 1 VM010H04R-R5P-P3 VM010H04R-R5P-F3 VM010H04R-R5P-A3 VM010H04R-R5P-C3 VM010H04R-R5P-B3 3/4 VM017C04R-R5P-P2 VM017C04R-R5P-F2 VM017C04R-R5P-A2 VM017C04R-R5P-C2 VM017C04R-R5P-B2 1 VM017C04R-R5P-P3 VM017C04R-R5P-F3 VM017C04R-R5P-A3 VM017C04R-R5P-C3 VM017C04R-R5P-B3 250 3/4 VM025C04R-R5P-P2 VM025C04R-R5P-F2 VM025C04R-R5P-A2 VM025C04R-R5P-C2 VM025C04R-R5P-B2 1 VM025C04R-R5P-P3 VM025C04R-R5P-F3 VM025C04R-R5P-A3 VM025C04R-R5P-C3 VM025C04R-R5P-B3 imensions: 13 3 /8" (340) 13 3 /8" (340) 13 3 /8" (340) 13 3 /8" (340) 14 7 /8" (378) 14 1 /4" (362) 14 1 /4" (362) 18 11 /16" (475) 14 1 /2" (368) 16 5 /8" (422) Rigid Flexible Cone Pendant Pendant Pendant Ceiling Wall 48 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Enclosed & Gasketed Fixtures for Adverse, Wet & Marine R-TANK BALLAST HOUSING WITH 7-3/4'' REFRACTOR AN GUAR Hazlux 2 50-250 Watts UL 1598 Enclosed and Gasketed Suitable for Wet Locations UL 595 Marine* NEMA 4X* Lamp Watts Hub Size 25 Stanchion Catalog Number Straight Stanchion Catalog Number HazVertor Ring Catalog Number Ordering Notes: 1. All fixtures (except 50W HPS and 70W MH) are shown with multi-tap ballast (120, 208, 240, 277V). To order 480V or any other dedicated voltage, substitute desired voltage code from Catalog Numbering System on page 41. Example: For 100W HPS, 480V, substitute H48 for H04 - VS010H48R-R5P- P2. Hazlux High Pressure Sodium 50 70 100 1-1/4 VS005H12R-R5P-S4 VS005H12R-R5P-L4 VS005H12R-R5P-HV1 1-1/2 VS005H12R-R5P-S5 VS005H12R-R5P-L5 1-1/4 VS007H04R-R5P-S4 VS007H04R-R5P-L4 VS007H04R-R5P-HV1 1-1/2 VS007H04R-R5P-S5 VS007H04R-R5P-L5 1-1/4 VS010H04R-R5P-S4 VS010H04R-R5P-L4 VS010H04R-R5P-HV1 1-1/2 VS010H04R-R5P-S5 VS010H04R-R5P-L5 2. All fixtures are for use with mogul base lamps. Lamps are not included unless UNIPAK with Lamp packaging is specified. See Note 43. 3. To order Hazlux 2 fixtures with UNIPAK with Lamp packaging, add E to the end of the catalog number. Example: VH017C04R- R5P-S5E. See page 43 for details. Metal Halide 150 70 100 175 1-1/4 VS015H04R-R5P-S4 VS015H04R-R5P-L4 VS015H04R-R5P-HV1 1-1/2 VS015H04R-R5P-S5 VS015H04R-R5P-L5 1-1/4 VH007H03R-R5P-S4 VH007H03R-R5P-L4 VH007H03R-R5P-HV1 1-1/2 VH007H03R-R5P-S5 VH007H03R-R5P-L5 1-1/4 VH010H04R-R5P-S4 VH010H04R-R5P-L4 VH010H04R-R5P-HV1 1-1/2 VH010H04R-R5P-S5 VH010H04R-R5P-L5 1-1/4 VH017C04R-R5P-S4 VH017C04R-R5P-L4 VH017C04R-R5P-HV1 1-1/2 VH017C04R-R5P-S5` VH017C04R-R5P-L5 4. Refer to Note Regarding Glass Globes and Refractors on page 5 for hose-down information. 5. Fixtures are shown with IES Type V refractor for symmetrical light distribution. To order with IES Type I or Type III refractor, substitute R1P or R3P for R5P in catalog number. Example: VS015H04R-R1P- L5. 6. Fixtures are shown with guard. To order fixture without guard, change R5P to R5. Example: VH017C04R-R5-C2. 7. Refer to page 41 for Hazlux 2 Options, and page 56 for Hazlux 2 Accessories and Parts. 250 1-1/4 VH025C04R-R5P-S4 VH025C04R-R5P-L4 VH025C04R-R5P-HV1 1-1/2 VH025C04R-R5P-S5 VH025C04R-R5P-L5 100 1-1/4 VM010H04R-R5P-S4 VM010H04R-R5P-L4 VM010H04R-R5P-HV1 1-1/2 VM010H04R-R5P-S5 VM010H04R-R5P-L5 Mercury Vapor 175 1-1/4 VM017C04R-R5P-S4 VM017C04R-R5P-L4 VM017C04R-R5P-HV1 1-1/2 VM017C04R-R5P-S5 VM017C04R-R5P-L5 250 1-1/4 VM025C04R-R5P-S4 VM025C04R-R5P-L4 VM025C04R-R5P-HV1 1-1/2 VM025C04R-R5P-S5 VM025C04R-R5P-L5 imensions: 16 1 /8" (410) 15 3 /4" (400) 13 3 /8" (340) 15 3 /16" (386) 15 3 /16" (386) 14 3 /4" (375) 25 Straight HazVertor Stanchion Stanchion Ring 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 49

Hazlux Enclosed & Gasketed Fixtures for Adverse, Wet & Marine R-TANK BALLAST HOUSING WITH 7-3/4'' GLOBE AN GUAR Hazlux 2 50-250 Watts UL 1598 Enclosed and Gasketed Suitable for Wet Locations UL 595 Marine* NEMA 4X* Rigid Pendant Catalog Number Flex. Pendant Catalog Number Cone Pendant Catalog Number Ceiling Catalog Number Wall Catalog Number Lamp Watts Hub Size 50 3/4 VS005H12R-TGP-P2 VS005H12R-TGP-F2 VS005H12R-TGP-A2 VS005H12R-TGP-C2 VS005H12R-TGP-B2 1 VS005H12R-TGP-P3 VS005H12R-TGP-F3 VS005H12R-TGP-A3 VS005H12R-TGP-C3 VS005H12R-TGP-B3 High Pressure Sodium 70 100 3/4 VS007H04R-TGP-P2 VS007H04R-TGP-F2 VS007H04R-TGP-A2 VS007H04R-TGP-C2 VS007H04R-TGP-B2 1 VS007H04R-TGP-P3 VS007H04R-TGP-F3 VS007H04R-TGP-A3 VS007H04R-TGP-C3 VS007H04R-TGP-B3 3/4 VS010H04R-TGP-P2 VS010H04R-TGP-F2 VS010H04R-TGP-A2 VS010H04R-TGP-C2 VS010H04R-TGP-B2 1 VS010H04R-TGP-P3 VS010H04R-TGP-F3 VS010H04R-TGP-A3 VS010H04R-TGP-C3 VS010H04R-TGP-B3 150 3/4 VS015H04R-TGP-P2 VS015H04R-TGP-F2 VS015H04R-TGP-A2 VS015H04R-TGP-C2 VS015H04R-TGP-B2 1 VS015H04R-TGP-P3 VS015H04R-TGP-F3 VS015H04R-TGP-A3 VS015H04R-TGP-C3 VS015H04R-TGP-B3 70 3/4 VH007H03R-TGP-P2 VH007H03R-TGP-F2 VH007H03R-TGP-A2 VH007H03R-TGP-C2 VH007H03R-TGP-B2 1 VH007H03R-TGP-P3 VH007H03R-TGP-F3 VH007H03R-TGP-A3 VH007H03R-TGP-C3 VH007H03R-TGP-B3 Metal Halide 100 175 3/4 VH010H04R-TGP-P2 VH010H04R-TGP-F2 VH010H04R-TGP-A2 VH010H04R-TGP-C2 VH010H04R-TGP-B2 1 VH010H04R-TGP-P3 VH010H04R-TGP-F3 VH010H04R-TGP-A3 VH010H04R-TGP-C3 VH010H04R-TGP-B3 3/4 VH017C04R-TGP-P2 VH017C04R-TGP-F2 VH017C04R-TGP-A2 VH017C04R-TGP-C2 VH017C04R-TGP-B2 1 VH017C04R-TGP-P3 VH017C04R-TGP-F3 VH017C04R-TGP-A3 VH017C04R-TGP-C3 VH017C04R-TGP-B3 250 3/4 VH025C04R-TGP-P2 VH025C04R-TGP-F2 VH025C04R-TGP-A2 VH025C04R-TGP-C2 VH025C04R-TGP-B2 1 VH025C04R-TGP-P3 VH025C04R-TGP-F3 VH025C04R-TGP-A3 VH025C04R-TGP-C3 VH025C04R-TGP-B3 Mercury Vapor 100 175 3/4 VM010H04R-TGP-P2 VM010H04R-TGP-F2 VM010H04R-TGP-A2 VM010H04R-TGP-C2 VM010H04R-TGP-B2 1 VM010H04R-TGP-P3 VM010H04R-TGP-F3 VM010H04R-TGP-A3 VM010H04R-TGP-C3 VM010H04R-TGP-B3 3/4 VM017C04R-TGP-P2 VM017C04R-TGP-F2 VM017C04R-TGP-A2 VM017C04R-TGP-C2 VM017C04R-TGP-B2 1 VM017C04R-TGP-P3 VM017C04R-TGP-F3 VM017C04R-TGP-A3 VM017C04R-TGP-C3 VM017C04R-TGP-B3 250 3/4 VM025C04R-TGP-P2 VM025C04R-TGP-F2 VM025C04R-TGP-A2 VM025C04R-TGP-C2 VM025C04R-TGP-B2 1 VM025C04R-TGP-P3 VM025C04R-TGP-F3 VM025C04R-TGP-A3 VM025C04R-TGP-C3 VM025C04R-TGP-B3 imensions: 13 3 /8" (340) 13 3 /8" (340) 13 3 /8" (340) 13 3 /8" (340) 14 14 7 /8" 7 /8" (377) 14 1 /4" (362) 14 1 /4" (362) 18 11 /16" (475) 14 1 /2" (368) 16 5 /8" (422) Rigid Flexible Cone Pendant Pendant Pendant Ceiling Wall 50 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Enclosed & Gasketed Fixtures for Adverse, Wet & Marine R-TANK BALLAST HOUSING WITH 7-3/4'' GLOBE AN GUAR Hazlux 2 50-250 Watts UL 1598 Enclosed and Gasketed Suitable for Wet Locations UL 595 Marine* NEMA 4X* Lamp Watts Hub Size 25 Stanchion Catalog Number Straight Stanchion Catalog Number HazVertor Ring Catalog Number Ordering Notes: 1. All fixtures (except 50W HPS and 70W MH) are shown with multi-tap ballast (120, 208, 240, 277V). To order 480V or any other dedicated voltage, substitute desired voltage code from Catalog Numbering System on page 41. Example: For 100W HPS, 480V, substitute H48 for H04 - VS010H48R-TGP- P2. Hazlux High Pressure Sodium 50 70 100 1-1/4 VS005H12R-TGP-S4 VS005H12R-TGP-L4 VS005H12R-TGP-HV1 1-1/2 VS005H12R-TGP-S5 VS005H12R-TGP-L5 1-1/4 VS007H04R-TGP-S4 VS007H04R-TGP-L4 VS007H04R-TGP-HV1 1-1/2 VS007H04R-TGP-S5 VS007H04R-TGP-L5 1-1/4 VS010H04R-TGP-S4 VS010H04R-TGP-L4 VS010H04R-TGP-HV1 1-1/2 VS010H04R-TGP-S5 VS010H04R-TGP-L5 2. All fixtures are for use with mogul base lamps. Lamps are not included unless UNIPAK with Lamp packaging is specified. See Note 43. 3. To order Hazlux 2 fixtures with UNIPAK with Lamp packaging, add E to the end of the catalog number. Example: VH017C04R- TGP-S5E. See page 43 for details. Metal Halide 150 70 100 1-1/4 VS015H04R-TGP-S4 VS015H04R-TGP-L4 VS015H04R-TGP-HV1 1-1/2 VS015H04R-TGP-S5 VS015H04R-TGP-L5 1-1/4 VH007H03R-TGP-S4 VH007H03R-TGP-L4 VH007H03R-TGP-HV1 1-1/2 VH007H03R-TGP-S5 VH007H03R-TGP-L5 1-1/4 VH010H04R-TGP-S4 VH010H04R-TGP-L4 VH010H04R-TGP-HV1 1-1/2 VH010H04R-TGP-S5 VH010H04R-TGP-L5 4. Refer to Note Regarding Glass Globes and Refractors on page 5 for hose-down information. 5. Fixtures are shown with guard. To order fixture without guard, change TGP to TG. Example: VH017C04R-TG-C2. 6. Refer to page 41 for Hazlux 2 Options, and page 56 for Hazlux 2 Accessories and Parts. 175 1-1/4 VH017C04R-TGP-S4 VH017C04R-TGP-L4 VH017C04R-TGP-HV1 1-1/2 VH017C04R-TGP-S5 VH017C04R-TGP-L5 250 1-1/4 VH025C04R-TGP-S4 VH025C04R-TGP-L4 VH025C04R-TGP-HV1 1-1/2 VH025C04R-TGP-S5 VH025C04R-TGP-L5 100 1-1/4 VM010H04R-TGP-S4 VM010H04R-TGP-L4 VM010H04R-TGP-HV1 1-1/2 VM010H04R-TGP-S5 VM010H04R-TGP-L5 Mercury Vapor 175 1-1/4 VM017C04R-TGP-S4 VM017C04R-TGP-L4 VM017C04R-TGP-HV1 1-1/2 VM017C04R-TGP-S5 VM017C04R-TGP-L5 250 1-1/4 VM025C04R-TGP-S4 VM025C04R-TGP-L4 VM025C04R-TGP-HV1 1-1/2 VM025C04R-TGP-S5 VM025C04R-TGP-L5 imensions: 16 1 /8" (410) 15 3 /4" (400) 13 3 /8" (340) 15 3 /16" (391) 15 3 /16" (386) 14 3 /4" (375) 25 Straight HazVertor Stanchion Stanchion Ring 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 51

Hazlux Enclosed & Gasketed Fixtures for Adverse, Wet & Marine LARGE BALLAST HOUSING WITH GLOBE AN GUAR Hazlux 2 200-400 WATTS UL 1598 Enclosed and Gasketed Suitable for Wet Locations UL 595 Marine* NEMA 4X* Rigid Pendant Catalog Number Cone Pendant Catalog Number Ceiling Catalog Number Wall Catalog Number Lamp Watts Hub Size High Pressure Sodium Metal Halide Mercury Vapor 200 250 400 400 400 3/4 VS020C04L-TGC-P2 VS020C04L-TGC-A2 VS020C04L-TGC-C2 VS020C04L-TGC-B2 1 VS020C04L-TGC-P3 VS020C04L-TGC-A3 VS020C04L-TGC-C3 VS020C04L-TGC-B3 3/4 VS025C04L-TGC-P2 VS025C04L-TGC-A2 VS025C04L-TGC-C2 VS025C04L-TGC-B2 1 VS025C04L-TGC-P3 VS025C04L-TGC-A3 VS025C04L-TGC-C3 VS025C04L-TGC-B3 3/4 VS040C04L-TGC-P2 VS040C04L-TGC-A2 VS040C04L-TGC-C2 VS040C04L-TGC-B2 1 VS040C04L-TGC-P3 VS040C04L-TGC-A3 VS040C04L-TGC-C3 VS040C04L-TGC-B3 3/4 VH040C04L-TGC-P2 VH040C04L-TGC-A2 VH040C04L-TGC-C2 VH040C04L-TGC-B3 1 VH040C04L-TGC-P3 VH040C04L-TGC-A3 VH040C04L-TGC-C3 VH040C04L-TGC-B3 3/4 VM040C04L-TGC-P2 VM040C04L-TGC-A2 VM040C04L-TGC-C2 VM040C04L-TGC-B2 1 VM040C04L-TGC-P3 VM040C04L-TGC-A3 VM040C04L-TGC-C3 VM040C04L-TGC-B3 imensions: 13 3 /8" (340) 13 3 /8" (340) 13 3 /8" (340) 14 7 /8" (378) 9 7 /8" (251) 11 5 /8" (295) 21 1 /2" (546) 14 3 /8" (365) 26" (660) 22 1 /8" (562) 24 3 /8" (619) Rigid Pendant Cone Pendant Ceiling Wall 52 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Enclosed & Gasketed Fixtures for Adverse, Wet & Marine LARGE BALLAST HOUSING WITH GLOBE AN GUAR Hazlux 2 200-400 WATTS UL 1598 Enclosed and Gasketed Suitable for Wet Locations UL 595 Marine* NEMA 4X* Lamp Watts Hub Size 25 Stanchion Catalog Number Straight Stanchion Catalog Number HazVertor Ring Catalog Number Ordering Notes: 1. All fixtures are shown with multi-tap ballast (120, 208, 240, 277V). To order 480V or any other dedicated voltage, substitute desired voltage code from Catalog Numbering System on page 41. Example: For 400W HPS, 480V, substitute H48 for H04 - VS040C48L-TGC- P2. Hazlux High Pressure Sodium Metal Halide Mercury Vapor 200 250 400 400 400 1-1/4 VS020C04L-TGC-S4 VS020C04L-TGC-L4 VS020C04L-TGC-HV1 1-1/2 VS020C04L-TGC-S5 VS020C04L-TGC-L5 1-1/4 VS025C04L-TGC-S4 VS025C04L-TGC-L4 VS025C04L-TGC-HV1 1-1/2 VS025C04L-TGC-S5 VS025C04L-TGC-L5 1-1/4 VS040C04L-TGC-S4 VS040C04L-TGC-L4 VS040C04L-TGC-HV1 1-1/2 VS040C04L-TGC-S5 VS040C04L-TGC-L5 1-1/4 VH040C04L-TGC-S4 VH040C04L-TGC-L4 VH040C04L-TGC-HV1 1-1/2 VH040C04L-TGC-S5 VH040C04L-TGC-L5 1-1/4 VM040C04L-TGC-S4 VM040C04L-TGC-L4 VM040C04L-TGC-HV1 1-1/2 VM040C04L-TGC-S5 VM040C04L-TGC-L5 2. All fixtures are for use with mogul base lamps. Lamps are not included unless UNIPAK with Lamp packaging is specified. See Note 43. 3. To order Hazlux 2 fixtures with UNIPAK with Lamp packaging, add E to the end fo the catalog number. Example: VH040C04L- TGC-S5E. See page 43 for details. 4. Refer to Note Regarding Glass Globes and Refractors on page 5 for hose-down information. 5. Fixtures are shown with guard. To order fixture without guard, change TGC to TG. Example: VH040C04L-TG-C2. 6. Refer to page 41 for Hazlux 2 Options, and page 56 for Hazlux 2 Accessories and Parts. imensions: 16 1 /8" (410) 15 3 /4" (400) 13 3 /8" (340) 23" (584) 23" (584) 23 3 /8" (594) 25 Straight HazVertor Stanchion Stanchion Ring 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 53

Hazlux Enclosed & Gasketed Fixtures for Adverse, Wet & Marine LARGE BALLAST HOUSING WITH 12'' REFRACTOR AN GUAR Hazlux 2 200-400 WATTS UL 1598 Enclosed and Gasketed Suitable for Wet Locations UL 595 Marine* NEMA 4X* Rigid Pendant Catalog Number Cone Pendant Catalog Number Ceiling Catalog Number Wall Catalog Number Lamp Watts Hub Size High Pressure Sodium Metal Halide Mercury Vapor 200 250 400 400 400 3/4 VS020C04L-R5G-P2 VS020C04L-R5G-A2 VS020C04L-R5G-C2 VS020C04L-R5G-B2 1 VS020C04L-R5G-P3 VS020C04L-R5G-A3 VS020C04L-R5G-C3 VS020C04L-R5G-B3 3/4 VS025C04L-R5G-P2 VS025C04L-R5G-A2 VS025C04L-R5G-C2 VS025C04L-R5G-B2 1 VS025C04L-R5G-P3 VS025C04L-R5G-A3 VS025C04L-R5G-C3 VS025C04L-R5G-B3 3/4 VS040C04L-R5G-P2 VS040C04L-R5G-A2 VS040C04L-R5G-C2 VS040C04L-R5G-B2 1 VS040C04L-R5G-P3 VS040C04L-R5G-A3 VS040C04L-R5G-C3 VS040C04L-R5G-B3 3/4 VH040C04L-R5G-P2 VH040C04L-R5G-A2 VH040C04L-R5G-C2 VH040C04L-R5G-B2 1 VH040C04L-R5G-P3 VH040C04L-R5G-A3 VH040C04L-R5G-C3 VH040C04L-R5G-B3 3/4 VM040C04L-R5G-P2 VM040C04L-R5G-A2 VM040C04L-R5G-C2 VM040C04L-R5G-B2 1 VM040C04L-R5G-P3 VM040C04L-R5G-A3 VM040C04L-R5G-C3 VM040C04L-R5G-B3 imensions: 13 3 /8" (340) 13 3 /8" (340) 13 3 /8" (340) 14 7 /8" (378) 20 7 /8" (530) 25 3 /8" (644) 21 1 /2" (546) 23 3 /4" (603) Rigid Pendant Cone Pendant Ceiling Wall 16 1 /8" (410) 26" (660) Cone Pendant with enclosed reflector 54 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Enclosed & Gasketed Fixtures for Adverse, Wet & Marine LARGE BALLAST HOUSING Hazlux 2 UL 1598 Enclosed and Gasketed Suitable for Wet Locations UL 595 Marine* NEMA 4X* WITH 12'' REFRACTOR AN GUAR 200-400 WATTS Lamp Watts Hub Size 25 Stanchion Catalog Number Straight Stanchion Catalog Number HazVertor Ring Catalog Number Ordering Notes: 1. All fixtures are shown with multi-tap ballast (120, 208, 240, 277V). To order 480V or any other dedicated voltage, substitute desired voltage code from Catalog Numbering System on page 41. Example: For 400W HPS, 480V, substitute H48 for H04 - VS040C48L-R5G- P2. Hazlux High Pressure Sodium Metal Halide Mercury Vapor 200 250 400 400 400 1-1/4 VS020C04L-R5G-S4 VS020C04L-R5G-L4 1-1/2 VS020C04L-R5G-S5 VS020C04L-R5G-L5 1-1/4 VS025C04L-R5G-S4 VS025C04L-R5G-L4 1-1/2 VS025C04L-R5G-S5 VS025C04L-R5G-L5 1-1/4 VS040C04L-R5G-S4 VS040C04L-R5G-L4 1-1/2 VS040C04L-R5G-S5 VS040C04L-R5G-L5 1-1/4 VH040C04L-R5G-S4 VH040C04L-R5G-L4 1-1/2 VH040C04L-R5G-S5 VH040C04L-R5G-L5 VS020C04L-R5G-HV1 VS025C04L-R5G-HV1 VS040C04L-R5G-HV1 VH040C04L-R5G-HV1 1-1/4 VM040C04L-R5G-S4 VM040C04L-R5G-L4 VM040C04L-R5G-HV1 1-1/2 VM040C04L-R5G-S5 VM040C04L-R5G-L5 2. All fixtures are for use with mogul base lamps. Lamps are not included unless UNIPAK with Lamp packaging is specified. See Note 43. 3. To order Hazlux 2 fixtures with UNIPAK with Lamp packaging, add E to the end fo the catalog number. Example: VH040C04L- R5G-S5E. See page 43 for details. 4. Refer to Note Regarding Glass Globes and Refractors on page 5 for hose-down information. 5. Fixtures are shown with IES Type V refractor for symmetrical light distribution. To order with IES Type II refractor, substitute R2G for R5G in catalog number. Example: VS040C04L-R2G-L5. imensions: 6. Fixtures are shown with guard. To order fixture without guard, change R5G to R5. Example: VH040C04L-R5-C2. 16 1 /8" (410) 15 3 /4" (400) 13 3 /8" (340) 7. To order fixtures with VR31CB High Bay Refllector with Lens, substitute RCB (no guard) or RCG (with guard) for R5G in catalog number. Example: VS040C04L-RCB-P2. 22 3 /8" (568) 22 3 /8" (568) 21 3 /4" (552) 8. Refer to page 41 for Hazlux 2 Options, and page 56 for Hazlux 2 Accessories and Parts. 25 Straight HazVertor Stanchion Stanchion Ring 16 1 /8" (410) 26" (660) Cone Pendant with enclosed reflector 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 55

Hazlux Enclosed & Gasketed Fixtures for Adverse, Wet & Marine COMPONENTS AN REPLACEMENT PARTS Hazlux 2 50-400 Watts UL 1598 Enclosed and Gasketed Suitable for Wet Locations UL 595 Marine* NEMA 4X* Mounting Covers Reflectors, Exit Sign Mounting Style Hub Size Catalog Number Mounting Style Hub Size Catalog Number Catalog Number escription Rigid Pendant Wall 3 4'' VP2 3 4'' VB2 1'' VP3 1'' VB3 Cone 25 Pendant Stanchion 3 4'' VA2 1 1 4'' VS4 1'' VA3 1 1 2'' VS5 Flexible Pendant Ceiling Globes, Refractors Straight Stanchion 3 4'' VF2 1 1 4'' VL4 1'' VF3 1 1 2'' VL5 HazVertor Ring 3 4'' VC2 HV1 1'' VC3 HV2 Catalog Number VGT22 escription 5 1 2'' dia. Heat Resistant Globe For use with Standard Housing (250W max.) VR22P VR31P VR31 VR31CB VRA22P VRA31P VRE22 Standard ome Fiberglass Reinforced Polyester For use with Std. Housing Standard ome Fiberglass Reinforced Polyester For use with R and Lg. Housings eep ome Anodized Aluminum For use with R and Lg. Housings Enclosed High Bay Anodized Aluminum with Lens For use with R and Lg. Housings 30 Angle Reflector Fiberglass Reinforced Polyester For use with Std. Housing 30 Angle Reflector Fiberglass Reinforced Polyester For use with R and Lg. Housings Three Sided Exit Sign For use with Std. Housing VGT31S VGT31 VGL31R1 VGL31R3 VGL31R5 VRF22C2 VRF22C5 VRF31C2 7 3 4'' dia. Heat Resistant Globe For use with R Housing (250W max.) 7 3 4'' dia. Heat Resistant Globe For use with Large Housing (400W max.) 7 3 4'' IES Type I Refractor Globe For use with R Housing (250W max.) 7 3 4'' IES Type III Refractor Globe For use with R Housing (250W max.) 7 3 4'' IES Type V Refractor Globe For use with R Housing (250W max.) 12'' dia. IES Type II Refractor 5 1 2'' thread, for use with Standard Housing 12'' dia. IES Type V Refractor 5 1 2'' thread, for use with Standard Housing 12'' dia. IES Type II Refractor 7 3 4'' thread, for use with R and Large Housings Guards Catalog Number VGU22P VGU31RP VGU31R VGU31 VGR48 VGR64 escription Polymeric Guard for VGT22 Series Globes Polymeric Guard for VGT31S Globe and VGL31R Series Refractor Globes Cast Aluminum Guard for VGT31S Globe and VGL31R Series Refractor Globes Cast Aluminum Guard for VGT31 Globe Steel Wire Guard for All VRF Series 12'' Refractors Steel Wire Guard for VR31CB Enclosed High Bay Reflector VRF31C5 12'' dia. IES Type V Refractor 7 3 4'' thread, for use with R and Large Housings 56 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Enclosed & Gasketed Fixtures for Adverse, Wet & Marine CATALOG NUMBERING SYSTEM HI INCANESCENT - FLUORESCENT Hazlite M2 9-150 Watts Catalog Numbering System UL 1598 Enclosed and Gasketed Suitable for Wet Locations Marine* NEMA 4X* V S M 07 P 120 - R5P - C2 E F 1 2 3 4 5 6 7 8 10 11 Hazlux 1) Fixture Suitability V = Enclosed & Gasketed Suitable for Wet Locations Marine NEMA 4X 2) Lamp Type S = High Pressure Sodium H = Metal Halide F = Fluorescent I = Incandescent 3) Lampholder Type M = Medium Base Lampholder B = Bi Pin Type (Fluorescent) 4) Lamp Wattage 09 = 9 Watts 13 = 13 Watts 18 = 18 Watts 26 = 26 Watts 03 = 35 Watts 05 = 50 Watts 07 = 70 Watts 10 = 100 Watts 15 = 150 Watts 5) Ballast Circuit C = Constant Wattage Autotransformer (CWA) P = Reactor Type 0 = Incandescent - No Ballast Circuit 6) Ballast Voltage 120 = 120 Volts 7) Optical Assembly Option G = Standard Globe Only (VGL15) GGL = Standard Globe and Polymeric Guard GG = Standard Globe and Cast Guard TG = Tempered Globe Only (VGL15) TGL = Tempered Globe and Polymeric Guard TGC = Tempered Globe and Cast Guard R1 = Type I (Long & Narrow) Glass Refractor R3 = Type III (Asymmetric) Glass Refractor R5 = Type V (Symmetric) Glass Refractor R1P = Type I Refractor and Polymeric Guard R3P = Type III Refractor and Polymeric Guard R5P = Type V Refractor and Polymeric Guard R5A = 8'' Glass Refractor (Type V) 8) Mounting Style P2 = 3/4'' Rigid Pendant C2 = 3/4'' Ceiling P3 = 1'' Rigid Pendant C3 = 1'' Ceiling B2 = 3/4'' Wall S4 = 1-1/4'' Stanchion B3 = 1'' Wall S5 = 1-1/2'' Stanchion L4 = 1-1/4'' Stanchion 010 = 4'' Cast Outlet Box L5 = 1-1/2'' Stanchion 9) Special Coating Options T = HAZ-COTE Custom Corrosion coating on all Aluminum Parts. (Consult Factory) 10) UNIPAK Options = Unipak with diffuse coated lamp E = Unipak with clear lamp (See page 217 for details) 11) Fusing F = Single Fuse Block with Fuse (HI only) (Not Marine Rated) Note: 100W incandesant not available in clear lamp. 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 57

Hazlux Enclosed & Gasketed Fixtures for Adverse, Wet & Marine FIXTURE COMPONENTS Hazlite M2 UL 1598 Enclosed and Gasketed Suitable for Wet Locations Marine* NEMA 4X* 9-150 Watts OUTLET BOXES esigned for all Hazlite M2 Ballast Housings. MOUNTING CATALOG CONUIT WT. EA. ST. STYLE NUMBER HUB SIZE (LBS.) PKG. Rigid Pendant VMP2 3/4 1.3 5 MOUNTING CATALOG CONUIT WT. EA. ST. STYLE NUMBER HUB SIZE (LBS.) PKG. Wall Mount VMB2 3/4 5.2 5 VMP3 1 1.3 5 VMB3 1 5.2 5 Ceiling Mount VMC2 3/4 1.9 5 Stanchion Mount VMS4 1 1 4 3.0 5 VMC3 1 1.9 5 25 VMS5 1 1 2 3.0 5 4'' Outlet Box Mount VM010 None 1.2 5 GLOBES OR REFRACTORS GUARS REFLECTORS CATALOG NO. Stanchion Mount 90 VML4 1 1 4 3.0 5 VML5 1 1 2 3.0 5 VGL15 Prismatic Glass 150 Watts Max. 10 2.8 VGT15 Heat-Resistant Prismatic Glass 10 2.8 VGL15R1 IES Type I Refractor 10 3.0 VGL15R3 IES Type III Refractor 10 3.0 VGL15R5 IES Type V Refractor 10 3.0 VRF22C5A 8'' IES Type V Reflector 10 5.0 VGT15G Green Prismatic Glass 10 2.8 VGL15P Clear Polycarbonate (60 Watt Max.) 10 1.0 VGL22P Clear Polycarbonate (100 Watt Max.) 10 1.0 CATALOG NO. VGU15 ESCRIPTION ESCRIPTION Cast aluminum - for use with glass globes or refractors ST. PKG. ST. PKG. 10.7 WEIGHT EACH (Lbs.) WEIGHT EACH (Lbs.) VGU15P Polymeric For Use With Glass Globes or Refractors 10.3 VGR32 For use with VRF22C5A Refractors 10 1.5 CATALOG NO. ESCRIPTION ST. PKG. WEIGHT EACH (Lbs.) VR15P Standard ome Fiber Glass Reinforced Polyester 5 2.4 EXIT SIGN VRA15P For use with Hazlite M2 type fixtures only. Factory Stock See General Information page 5 for Note Regarding Glass Globes and Refractors. * 30 Angle Reflector Fiber Glass Reinforced Polyester 5 2.3 CATALOG NO. WEIGHT EACH ST. PKG. COLOR (Lbs.) VRE22.5 1 Red VGE22.5 1 Green 58 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Enclosed & Gasketed Fixtures for Adverse, Wet & Marine FIXTURE COMPONENTS Hazlite M2 UL 1598 Enclosed and Gasketed Suitable for Wet Locations Marine* NEMA 4X* 9-150 Watts BALLAST HOUSINGS HIGH PRESSURE SOIUM High Power Factor-Reactor Type Ballast (Min. P.F. 90%) WATTAGE VOLTAGE WEIGHT EACH (Lbs.) ST. PKG. 35 120 5.7 VSM03P12 1 50 120 6.2 VSM05P12 1 70 120 6.4 VSM07P12 1 100 120 6.9 VSM10P12 1 150 120 7.9 VSM15P12 1 Hazlux BALLAST HOUSINGS METAL HALIE High Power Factor (Min. P.F. 90%) WATTAGE VOLTAGE WEIGHT EACH (Lbs.) ST. PKG. 70 120 7.7 VHM07H12 1 100 120 7.9 VHM10H12 1 BALLAST HOUSING AN GLOBE FLUORESCENT 1 Includes Globe and Lamp(s) shipped assembled to tank. WATTAGE VOLTAGE WEIGHT EACH (Lbs.) ST. PKG. 9 120 8.5 VFB09P120G- 1 13 120 8.5 VFB13P120G- 1 18 120 10.9 VFB18P120G- 1 26 120 10.9 VFB26P120G- 1 HOUSING INCANESCENT WATTAGE VOLTAGE WEIGHT EACH (Lbs.) ST. PKG. 100 120 2.6 VIM10012 1 150 120 2.6 VIM15012 1 1 Lamp (one or two) included with ballast housing (Fluorescent fixture only.) See General Information page 5 for Note Regarding Glass Globes and Refractors. * 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 59

Hazlux Enclosed & Gasketed Fixtures for Adverse, Wet & Marine HIGH PRESSURE SOIUM WITH GLOBE AN GUAR Hazlite M2 35-150 Watts UL 1598 Enclosed and Gasketed Suitable for Wet Locations Marine* NEMA 4X* MOUNTING STYLE Rigid Pendant Ceiling Mount Wall Mount Stanchion Mount LAMP WATTS CONUIT SIZE (Inches) 120 Volt WT. EACH (Lbs.) Ballast Housing CONSISTS OF: 35 3/4 VSM03P12-GGL-P2 10.1 VSM03P12 VMP2 VGL15 VGU15P 35 1 VSM03P12-GGL-P3 10.1 VSM03P12 VMP3 VGL15 VGU15P 50 3/4 VSM05P12-GGL-P2 10.6 VSM05P12 VMP2 VGL15 VGU15P 50 1 VSM05P12-GGL-P3 10.6 VSM05P12 VMP3 VGL15 VGU15P 70 3/4 VSM07P12-TGL-P2 11.0 VSM07P12 VMP2 VGT15 VGU15P 70 1 VSM07P12-TGL-P3 11.0 VSM07P12 VMP3 VGT15 VGU15P 100 3/4 VSM10P12-TGL-P2 11.3 VSM10P12 VMP2 VGT15 VGU15P 100 1 VSM10P12-TGL-P3 11.3 VSM10P12 VMP3 VGT15 VGU15P 150 3/4 VSM15P12-TGL-P2 12.3 VSM15P12 VMP2 VGT15 VGU15P 150 1 VSM15P12-TGL-P3 12.3 VSM15P12 VMP3 VGT15 VGU15P 35 3/4 VSM03P12-GGL-C2 10.7 VSM03P12 VMC2 VGL15 VGU15P 35 1 VSM03P12-GGL-C3 10.7 VSM03P12 VMC3 VGL15 VGU15P 50 3/4 VSM05P12-GGL-C2 11.2 VSM05P12 VMC2 VGL15 VGU15P 50 1 VSM05P12-GGL-C3 11.2 VSM05P12 VMC3 VGL15 VGU15P 70 3/4 VSM07P12-TGL-C2 11.4 VSM07P12 VMC2 VGT15 VGU15P 70 1 VSM07P12-TGL-C3 11.4 VSM07P12 VMC3 VGT15 VGU15P 100 3/4 VSM10P12-TGL-C2 11.9 VSM10P12 VMC2 VGT15 VGU15P 100 1 VSM10P12-TGL-C3 11.9 VSM10P12 VMC3 VGT15 VGU15P 150 3/4 VSM15P12-TGL-C2 12.9 VSM15P12 VMC3 VGT15 VGU15P 150 1 VSM15P12-TGL-C3 12.9 VSM15P12 VMC3 VGT15 VGU15P 35 3/4 VSM03P12-GGL-B2 14.0 VSM03P12 VMB2 VGL15 VGU15P 35 1 VSM03P12-GGL-B3 14.0 VSM03P12 VMB3 VGL15 VGU15P 50 3/4 VSM05P12-GGL-B2 14.5 VSM05P12 VMB2 VGL15 VGU15P 50 1 VSM05P12-GGL-B3 14.5 VSM05P12 VMB3 VGL15 VGU15P 70 3/4 VSM07P12-TGL-B2 14.7 VSM07P12 VMB2 VGT15 VGU15P 70 1 VSM07P12-TGL-B3 14.7 VSM07P12 VMB3 VGT15 VGU15P 100 3/4 VSM10P12-TGL-B2 15.2 VSM10P12 VMB2 VGT15 VGU15P 100 1 VSM10P12-TGL-B3 15.2 VSM10P12 VMB3 VGT15 VGU15P 150 3/4 VSM15P12-TGL-B2 16.2 VSM15P12 VMB2 VGT15 VGU15P 150 1 VSM15P12-TGL-B3 16.2 VSM15P12 VMB3 VGT15 VGU15P 35 1-1/4 VSM03P12-GGL-S4 11.8 VSM03P12 VMS4 VGL15 VGU15P 35 1-1/2 VSM03P12-GGL-S5 11.8 VSM03P12 VMS5 VGL15 VGU15P 50 1-1/4 VSM05P12-GGL-S4 12.3 VSM05P12 VMS4 VGL15 VGU15P 50 1-1/2 VSM05P12-GGL-S5 12.3 VSM05P12 VMS5 VGL15 VGU15P 70 1-1/4 VSM07P12-TGL-S4 12.5 VSM07P12 VMS4 VGT15 VGU15P 70 1-1/2 VSM07P12-TGL-S5 12.5 VSM07P12 VMS5 VGT15 VGU15P 100 1-1/4 VSM10P12-TGL-S4 13.0 VSM10P12 VMS4 VGT15 VGU15P 100 1-1/2 VSM10P12-TGL-S5 13.0 VSM10P12 VMS5 VGT15 VGU15P 150 1-1/4 VSM15P12-TGL-S4 14.0 VSM15P12 VMS4 VGT15 VGU15P 150 1-1/2 VSM15P12-TGL-S5 14.0 VSM15P12 VMS5 VGT15 VGU15P Outlet Box Globe Guard Standard ome Reflector: Angle Reflector: GUAR: If a guard is not required change Catalog No. VR15P Catalog No. VRA15P GGL to G or TGL to TG. All fixtures are designed for medium base lamps, with the lamp mounted in the base-up position (lamps are NOT furnished with fixture). See General Information page 5 for Note Regarding Glass Globes and Refractors. * 60 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Enclosed & Gasketed Fixtures for Adverse, Wet & Marine HIGH PRESSURE SOIUM WITH REFRACTOR AN GUAR (IES TYPE V, REFRACTOR) Hazlite M2 35-150 Watts UL 1598 Enclosed and Gasketed Suitable for Wet Locations Marine* NEMA 4X* MOUNTING STYLE Rigid Pendant Ceiling Mount Wall Mount Stanchion Mount LAMP WATTS CONUIT SIZE (Inches) 120 Volt WT. EACH (Lbs.) Ballast Housing CONSISTS OF: Refractor 35 3/4 VSM03P12-R5P-P2 10.3 VSM03P12 VMP2 VGL15R5 VGU15P 35 1 VSM03P12-R5P-P3 10.3 VSM03P12 VMP3 VGL15R5 VGU15P 50 3/4 VSM05P12-R5P-P2 10.8 VSM05P12 VMP2 VGL15R5 VGU15P 50 1 VSM05P12-R5P-P3 10.8 VSM05P12 VMP3 VGL15R5 VGU15P 70 3/4 VSM07P12-R5P-P2 11.0 VSM07P12 VMP2 VGL15R5 VGU15P 70 1 VSM07P12-R5P-P3 11.0 VSM07P12 VMP3 VGL15R5 VGU15P 100 3/4 VSM10P12-R5P-P2 11.5 VSM10P12 VMP2 VGL15R5 VGU15P 100 1 VSM10P12-R5P-P3 11.5 VSM10P12 VMP3 VGL15R5 VGU15P 150 3/4 VSM15P12-R5P-P2 12.5 VSM15P12 VMP2 VGL15R5 VGU15P 150 1 VSM15P12-R5P-P3 12.5 VSM15P12 VMP3 VGL15R5 VGU15P 35 3/4 VSM03P12-R5P-C2 10.9 VSM03P12 VMC2 VGL15R5 VGU15P 35 1 VSM03P12-R5P-C3 10.9 VSM03P12 VMC3 VGL15R5 VGU15P 50 3/4 VSM05P12-R5P-C2 11.4 VSM05P12 VMC2 VGL15R5 VGU15P 50 1 VSM05P12-R5P-C3 11.4 VSM05P12 VMC3 VGL15R5 VGU15P 70 3/4 VSM07P12-R5P-C2 11.6 VSM07P12 VMC2 VGL15R5 VGU15P 70 1 VSM07P12-R5P-C3 11.6 VSM07P12 VMC3 VGL15R5 VGU15P 100 3/4 VSM10P12-R5P-C2 12.1 VSM10P12 VMC2 VGL15R5 VGU15P 100 1 VSM10P12-R5P-C3 12.1 VSM10P12 VMC3 VGL15R5 VGU15P 150 3/4 VSM15P12-R5P-C2 13.1 VSM15P12 VMC2 VGL15R5 VGU15P 150 1 VSM15P12-R5P-C3 13.1 VSM15P12 VMC3 VGL15R5 VGU15P 35 3/4 VSM03P12-R5P-B2 14.2 VSM03P12 VMB2 VGL15R5 VGU15P 35 1 VSM03P12-R5P-B3 14.2 VSM03P12 VMB3 VGL15R5 VGU15P 50 3/4 VSM05P12-R5P-B2 14.7 VSM05P12 VMB2 VGL15R5 VGU15P 50 1 VSM05P12-R5P-B3 14.7 VSM05P12 VMB3 VGL15R5 VGU15P 70 3/4 VSM07P12-R5P-B2 14.9 VSM07P12 VMB2 VGL15R5 VGU15P 70 1 VSM07P12-R5P-B3 14.9 VSM07P12 VMB3 VGL15R5 VGU15P 100 3/4 VSM10P12-R5P-B2 15.4 VSM10P12 VMB2 VGL15R5 VGU15P 100 1 VSM10P12-R5P-B3 15.4 VSM10P12 VMB3 VGL15R5 VGU15P 150 3/4 VSM15P12-R5P-B2 16.4 VSM15P12 VMB2 VGL15R5 VGU15P 150 1 VSM15P12-R5P-B3 16.4 VSM15P12 VMB3 VGL15R5 VGU15P 35 1-1/4 VSM03P12-R5P-S4 12.0 VSM03P12 VMS4 VGL15R5 VGU15P 35 1-1/2 VSM03P12-R5P-S5 12.0 VSM03P12 VMS5 VGL15R5 VGU15P 50 1-1/4 VSM05P12-R5P-S4 12.5 VSM05P12 VMS4 VGL15R5 VGU15P 50 1-1/2 VSM05P12-R5P-S5 12.5 VSM05P12 VMS5 VGL15R5 VGU15P 70 1-1/4 VSM07P12-R5P-S4 12.7 VSM07P12 VMS4 VGL15R5 VGU15P 70 1-1/2 VSM07P12-R5P-S5 12.7 VSM07P12 VMS5 VGL15R5 VGU15P 100 1-1/4 VSM10P12-R5P-S4 13.2 VSM10P12 VMS4 VGL15R5 VGU15P 100 1-1/2 VSM10P12-R5P-S5 13.2 VSM10P12 VMS5 VGL15R5 VGU15P 150 1-1/4 VSM15P12-R5P-S4 14.2 VSM15P12 VMS4 VGL15R5 VGU15P 150 1-1/2 VSM15P12-R5P-S5 14.2 VSM15P12 VMS5 VGL15R5 VGU15P Outlet Box Guard Hazlux GUAR: If a guard is not required delete P from the Catalog Number. All fixtures are designed for medium base lamps, with the lamp mounted in the base-up position (lamps are NOT furnished with fixture). Refer to Page 58 for type I or III refractors. See General Information page 5 for Note Regarding Glass Globes and Refractors. * 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 61

Hazlux Enclosed & Gasketed Fixtures for Adverse, Wet & Marine METAL HALIE WITH GLOBE AN GUAR Hazlite M2 UL 1598 Enclosed and Gasketed Suitable for Wet Locations Marine* NEMA 4X* 50-100 Watts MOUNTING STYLE Rigid Pendant LAMP WATTS CONUIT SIZE (Inches) 120 Volt* WT. EACH (Lbs.) Ballast Housing CONSISTS OF: 70 3/4 VHM07H120-TGL-P2 12.1 VHM07H12 VMP2 VGT15 VGU15P Outlet Box 70 1 VHM07H120-TGL-P3 12.1 VHM07H12 VMP3 VGT15 VGU15P Globe Guard 100 3/4 VHM10H120-TGL-P2 12.3 VHM10H12 VMP2 VGT15 VGU15P Ceiling Mount 100 1 VHM10H120-TGL-P3 12.3 VHM10H12 VMP3 VGT15 VGU15P 70 3/4 VHM07H120-TGL-C2 12.7 VHM07H12 VMC2 VGT15 VGU15P 70 1 VHM07H120-TGL-C3 12.7 VHM07H12 VMC3 VGT15 VGU15P 100 3/4 VHM10H120-TGL-C2 12.9 VHM10H12 VMC2 VGT15 VGU15P Wall Mount 100 1 VHM10H120-TGL-C3 12.9 VHM10H12 VMC3 VGT15 VGU15P 70 3/4 VHM07H120-TGL-B2 16.0 VHM07H12 VMB2 VGT15 VGU15P 70 1 VHM07H120-TGL-B3 16.0 VHM07H12 VMB3 VGT15 VGU15P 100 3/4 VHM10H120-TGL-B2 16.2 VHM10H12 VMB2 VGT15 VGU15P Stanchion Mount 100 1 VHM10H120-TGL-B3 16.2 VHM10H12 VMB3 VGT15 VGU15P 70 1-1/4 VHM07H120-TGL-S4 13.8 VHM07H12 VMS4 VGT15 VGU15P 70 1-1/2 VHM07H120-TGL-S5 13.8 VHM07H12 VMS5 VGT15 VGU15P 100 1-1/4 VHM10H120-TGL-S4 14.0 VHM10H12 VMS4 VGT15 VGU15P 100 1-1/2 VHM10H120-TGL-S5 14.0 VHM10H12 VMS5 VGT15 VGU15P Standard ome Reflector: Angle Reflector: GUAR: If a guard is not required change Catalog No. VR15P Catalog No. VRA15P GGL to G or TGL to TG. All fixtures are designed for medium base lamps, with the lamp mounted in the base-up position (lamps are NOT furnished with fixture). See General Information page 5 for Note Regarding Glass Globes and Refractors. * 62 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Enclosed & Gasketed Fixtures for Adverse, Wet & Marine FLUORESCENT WITH GLOBE AN GUAR Hazlite M2 UL 1598 Enclosed and Gasketed Suitable for Wet Locations Marine* NEMA 4X* 9-26 Watts MOUNTING STYLE Rigid Pendant Ceiling Mount Wall Mount Stanchion Mount LAMP WATTS CONUIT SIZE (Inches) 120 Volt WT. EACH (Lbs.) Ballast Housing, Globe & Lamp(s) CONSISTS OF: Outlet Box Guard 9 3/4 VFB09P120-GGL-P2 10.1 VFB09P120G VMP2 VGU15P 9 1 VFB09P120-GGL-P3 10.1 VFB09P120G VMP3 VGU15P 13 3/4 VFB13P120-GGL-P2 10.1 VFB13P120G VMP2 VGU15P 13 1 VFB13P120-GGL-P3 10.1 VFB13P120G VMP3 VGU15P 18 3/4 VFB18P120-GGL-P2 10.5 VFB18P120G VMP2 VGU15P 18 1 VFB18P120-GGL-P3 10.5 VFB18P120G VMP3 VGU15P 26 3/4 VFB26P120-GGL-P2 10.5 VFB26P120G VMP2 VGU15P 26 1 VFB26P120-GGL-P3 10.5 VFB26P120G VMP3 VGU15P 9 3/4 VFB09P120-GGL-C2 10.7 VFB09P120G VMC2 VGU15P 9 1 VFB09P120-GGL-C3 10.7 VFB09P120G VMC3 VGU15P 13 3/4 VFB13P120-GGL-C2 10.7 VFB13P120G VMC2 VGU15P 13 1 VFB13P120-GGL-C3 10.7 VFB13P120G VMC3 VGU15P 18 3/4 VFB18P120-GGL-C2 11.1 VFB18P120G VMC2 VGU15P 18 1 VFB18P120-GGL-C3 11.1 VFB18P120G VMC3 VGU15P 26 3/4 VFB26P120-GGL-C2 11.1 VFB26P120G VMC3 VGU15P 26 1 VFB26P120-GGL-C3 11.1 VFB26P120G VMC3 VGU15P 9 3/4 VFB09P120-GGL-B2 14.0 VFB09P120G VMB2 VGU15P 9 1 VFB09P120-GGL-B3 14.0 VFB09P120G VMB3 VGU15P 13 3/4 VFB13P120-GGL-B2 14.0 VFB13P120G VMB2 VGU15P 13 1 VFB13P120-GGL-B3 14.0 VFB13P120G VMB3 VGU15P 18 3/4 VFB18P120-GGL-B2 14.4 VFB18P120G VMB2 VGU15P 18 1 VFB18P120-GGL-B3 14.4 VFB18P120G VMB3 VGU15P 26 3/4 VFB26P120-GGL-B2 14.4 VFB26P120G VMB2 VGU15P 26 1 VFB26P120-GGL-B3 14.4 VFB26P120G VMB3 VGU15P 9 1-1/4 VFB09P120-GGL-S2 11.8 VFB09P120G VMS4 VGU15P 9 1-1/2 VFB09P120-GGL-S3 11.8 VFB09P120G VMS5 VGU15P 13 1-1/4 VFB13P120-GGL-S2 11.8 VFB13P120G VMS4 VGU15P 13 1-1/2 VFB13P120-GGL-S3 11.8 VFB13P120G VMS5 VGU15P 18 1-1/4 VFB18P120-GGL-S2 11.8 VFB18P120G VMS4 VGU15P 18 1-1/2 VFB18P120-GGL-S3 11.8 VFB18P120G VMS5 VGU15P 26 1-1/4 VFB26P120-GGL-S2 11.8 VFB26P120G VMS4 VGU15P 26 1-1/2 VFB26P120-GGL-S3 11.8 VFB26P120G VMS5 VGU15P Hazlux Standard ome Reflector: Angle Reflector: GUAR: If a guard is not required delete Catalog No. VR15P Catalog No. VRA15P GL from the Catalog Number. Fluorescent fixtures use PL type lamps (one or two lamps included). See General Information page 5 for Note Regarding Glass Globes and Refractors. * 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 63

Hazlux Enclosed & Gasketed Fixtures for Adverse, Wet & Marine INCANESCENT WITH GLOBE AN GUAR Hazlite M2 UL 1598 Enclosed and Gasketed Suitable for Wet Locations Marine* NEMA 4X* 100-150 Watts MOUNTING STYLE Rigid Pendant Ceiling Mount Wall Mount Stanchion Mount LAMP WATTS CONUIT SIZE (Inches) WT. EACH (Lbs.) Ballast Housing CONSISTS OF: 100 3/4 VIM10012-GGL-P2 7.0 VIM10012 VMP2 VGL15 VGU15P 100 1 VIM10012-GGL-P3 7.0 VIM10012 VMP3 VGL15 VGU15P 150 3/4 VIM15012-GGL-P2 7.0 VIM15012 VMP2 VGL15 VGU15P 150 1 VIM15012-GGL-P3 7.0 VIM15012 VMP3 VGL15 VGU15P 100 3/4 VIM10012-GGL-C2 7.6 VIM10012 VMC2 VGL15 VGU15P 100 1 VIM10012-GGL-C3 7.6 VIM10012 VMC3 VGL15 VGU15P 150 3/4 VIM15012-GGL-C2 7.6 VIM15012 VMC3 VGL15 VGU15P 150 1 VIM15012-GGL-C3 7.6 VIM15012 VMC3 VGL15 VGU15P 100 3/4 VIM10012-GGL-B2 10.9 VIM10012 VMB2 VGL15 VGU15P 100 1 VIM10012-GGL-B3 10.9 VIM10012 VMB3 VGL15 VGU15P 150 3/4 VIM15012-GGL-B2 10.9 VIM15012 VMB2 VGL15 VGU15P 150 1 VIM15012-GGL-B3 10.9 VIM15012 VMB3 VGL15 VGU15P 100 1-1/4 VIM10012-GGL-S4 8.7 VIM10012 VMS4 VGL15 VGU15P 100 1-1/2 VIM10012-GGL-S5 8.7 VIM10012 VMS5 VGL15 VGU15P 150 1-1/4 VIM15012-GGL-S4 8.7 VIM15012 VMS4 VGL15 VGU15P 150 1-1/2 VIM15012-GGL-S5 8.7 VIM15012 VMS5 VGL15 VGU15P Outlet Box Globe Guard Standard ome Reflector: Angle Reflector: GUAR: If a guard is not required delete Catalog No. VR15P Catalog No. VRA15P GL from the Catalog Number. Incandescent fixtures use medium base lamps in the base-up position (lamp NOT included). See General Information page 5 for Note Regarding Glass Globes and Refractors. * 64 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Enclosed & Gasketed Fixtures for Adverse, Wet & Marine Hazlite M2 imensional rawings 8-5/8'' (219) 1-3/8'' (35) 4-3/16'' 4-3/16'' (106) (106) 6-1/2'' 6-1/2'' (165) (165) RIGI PENANT 2'' (51) 9-3/4'' (248) 11'' (279) 15-3/8'' (391) 4-9/16'' (116) 4-3/16'' (106) 6-11/16'' (170) 14-9/16'' 14-9/16'' (370) (370) 10-1/4'' 10-1/4'' (260) (260) 9-1/4'' (236) (235) 15-7/8'' (403) 2-7/8'' (73) 4-3/16'' (106) (106) 6-1/2'' (165) Hazlux 15-7/8'' (403) WALL MOUNT 90 STANCHION MOUNT 9-5/8'' (244) 1-3/4'' (44) 4-3/16'' (106) 6-1/2'' (165) 14-9/16'' (370) 10-1/4'' (260) 9-1/4'' (235) 2-7/8'' (73) 4-3/16'' (106) CEILING MOUNT 6-1/2'' (165) 15-7/8'' (403) 25 STANCHION MOUNT 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 65

Fixtures for Class I, ivision 2; Class II; Wet & Marine HI ENCLOSE and GASKETE FIXTURES for CLASS I, IVISION 2; CLASS II; WET and MARINE LOCATIONS* CONTENTS PAGE Hazlux Hazlux 3...69 HI, Mogul Base; 50-400W Hazlite M3...96 HI, Medium Base; 9-150W Compact Fluorescent Incandescent Hazlux 1 and Hazlite M1...19 and 31 *Check individual product listings for specific suitabilities. 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 67

Hazlux Fixtures for Class I, ivision 2; Class II; Wet & Marine Over six times the life of a traditional Metal Halide Lamp! I sure don t envy the person who has to change these lamps out! Hazlux Induction Lighting reduces the cost of expensive maintenance of industrial lighting in hazardous locations. Here s how you save maintenance costs with Hazlux Induction Lighting: Eliminates the need for expensive HI options such as Quartz Auxiliary Lamps or Instant Restrike. Reduces risks to installers performing maintenance in hard-to-reach places. Reduces number of times necessary to deenergize entire circuit of lights for maintenance in hazardous locations. Increases efficiency by decreasing machine shutdown time. Lowers cost of expensive rental of scissor lifts or bucket trucks. Now you can use the longest-life lamp available on the market. In the typical process industry plant, reliable lighting is often required in hazardous, hard-toreach places. Lamp replacement not only places employees at risk, but often requires the rental of expensive equipment such as scissors lifts. With the introduction of Hazlux Induction Lighting Fixtures for hazardous areas (Class 1, iv. 2 Groups A, B, C, ) and non-hazardous areas, you can benefit from the longest lamp life available on the market. Hazlux 3 HI lights are equipped with Philips QL Induction lamps for the longest lamp life ever. Features include: 60,000+ hour lamp life Reduced maintenance/re-lamp operations Instant On-Instant Restrike Automatic switch-off in case of failure Warm white light Exceptional energy efficiency -40 C to 40 C ambient operating range Retrofits into existing Hazlux 3 applications Acceptable for use with infrared remote control equipment operating at 36kHz. RFI-approved for environments up to 1000 MHz (FCC part 18 reference luminaire) Hazlux 3 Induction Lighting Fixture Ordering Information I 0 16 E 12 L - R5G - P2 T E 1 2 3 4 5 6 7 8 9 10 11 1. = Hazlux 3 HI Fixture Class I, iv. 2, Groups A, B, C, and Class I, Zone 2, Groups IIA, IIB, IIC Class II, iv. 1 & 2, Groups E, F, G Class III UL 595 Marine Locations Wet Locations, NEMA 4X 2. Lamp Type I = Induction Lighting 3. Starter Circuit/Quartz Options 0 = Standard Fixture 4. Lamp Wattage 16 = 165 watt induction system 5. Ballast Circuit E = Electronic Ballast (Induction Fixture) 6. Voltage 12 = 120V 60 Hz 06 = 208/240/277V 50 or 60 Hz 34 = 347V 60Hz (CSA) 7. Tank L = Large Tank 8. Refractor R5G = Type V Refractor with Wire Guard R5 = Type V Refractor 9. Mount A2 = f" Cone Top Pendant A3 = 1" Cone Top Pendant Mount B2 = f" Wall Mount B3 = 1" Wall Mount C2 = f" Ceiling Mount C3 = 1" Ceiling Mount F2 = f" Flexible Pendant F3 = 1" Flexible Pendant HV1 = Hazvertor Ring Class I, iv 2 HV2 = Hazvertor Ring Class II, ivision I L4 = 1b" Straight Stanchion L5 = 1d" Straight Stanchion P2 = f" Rigid Pendant P3 = 1" Rigid Pendant S4 = 1b" 25 egree Stanchion S5 = 1d" 25 egree Stanchion 10. Coating T = HazCote Custom Corrosion Coating 11. E = UNIPAK with Induction Lamp 68 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com

Fixtures for Class I, ivision 2; Class II; Wet & Marine HI Lighting Fixtures Hazlux 3 Mogul Base 50-400 Watts UL 844 Class I, ivision 2, Groups A, B, C, * Class II, ivision 1&2, Groups E, F, G; Class III Enclosed and Gasketed UL 1598, Suitable for Wet Locations Marine NEMA 4X Applications Chemical Plants Oil Refineries Paint, Rubber Manufacturing Offshore Platforms Oil rilling Rigs Oil, Gas Transmission Waste Treatment Facilities Airplane, Aerospace Facilities Electronics Manufacturing Pharmaceutical Plants Aircraft Manufacturing Vehicle Maintenance Facilities Grain Handling, Food Processing Coal Handling and Processing Flour, Sugar, Starch Processing Ammunition Manufacturing Coal, Gold and Copper Mining Pulp and Paper Manufacturing Copper, Aluminum Smelting Breweries, Malt Plants Shipyards, Shipbuilding Facilities Automobile Manufacturing Marine and Coastal Facilities Utility Power Plants Steel Mills, Foundries General Manufacturing Plants Hazlux Features and Benefits Modular fixture components enable hundreds of easy-to-assemble combinations. Cast copper-free aluminum housings and mounting covers for light weight and corrosion resistance. Electrostatically applied powder coat finish for added corrosion resistance. Thermal shock resistant glass globes and refractors protect lamps in wet, marine, outdoor applications. All glass globes and refractors are fully threaded and provide dust-tight, watertight seal with silicone rubber gaskets. Standard globe guards are made from rugged polycarbonate plastic or cast aluminum, with keyhole slots for ease of installation, and do not interfere with globe threads. All exposed hardware is stainless steel for corrosion resistance; screws are slotted, hex-head style to further ease installation. Comprehensive UL listings for Class I, ivision 2; Class I, Zone 2; and Class II. Available for use with High Pressure Sodium, Metal Halide, and Mercury Vapor lamps up to 400 watts. Eight different mounting styles Rigid Pendant, Flexible Pendant, Cone Pendant, Ceiling, Wall, 25 Stanchion, Straight Stanchion, and HazVertor Adapter Ring. Three ballast housing choices Standard Tank, R - Tank, and Large Tank. Heat sinks in ballast housings allow ballasts to operate cooler, provide longer life, improved temperature performance. Bright white FRP (fiberglass reinforced polyester) angle or dome reflectors resist corrosion while maximizing lighting effectiveness. Many optical choices standard globes, threaded refractor globes, 7 3 4 globes, 12 refractors, enclosed high bay reflectors, and more. All mounting covers provided with dual lead ground wire for connection to field and fixture grounds. Optional HazCote coating for extremely corrosive applications. Optional stainless steel inserts for guard screws and ballast tank closure screw for enhanced corrosion resistance. Optional TuffSkin silicone coating on glass optics contains fragments if glass is broken (for food processing). Optional instant restrike starter for HPS lamps up to 150 watts restarts hot HPS lamp after momentary power failure. Materials and Finishes Ballast Housings Copper free aluminum, powder finish Mounting Covers Copper free aluminum, powder finish Guards Polycarbonate, copper free aluminum, or steel Globes Tempered glass or borosilicate glass Refractor Globes Borosilicate glass Refractors (12 ) - Borosilicate glass Hardware Stainless steel Reflectors Fiberglass reinforced polyester (Std. dome, angle); anodized aluminum (deep dome, high bay enclosed) Gaskets High temperature silicone rubber Certifications UL Listed (UL844) for: Class I, ivision 2, Groups A, B, C, Class I, Zone 2, Groups IIA, IIB, IIC Class II, ivisions 1 & 2, Groups E, F, G Class III Wet Locations UL Listed (UL595) for: Marine Locations NEMA 4X, IP66 CSA Certified (Contact Hazlux) * See page 9 for T-Code Rating See pages 6 and 7 for Ratings on Specific Wattages. 2002 Thomas & Betts Corporation. Specifications are subject to change without notice. www.tnb.com 69