Hydronic Assemblies Inc. 56 Horse Hill Rd Concord NH 2015-2016 Hydronic Mechanical Panels Contact 4805 Main St. Waitsfield, Vermont 05673 Phone : 802-583-5500 WWW.Houseneeds.com Hydronic Assemblies Inc. 2015-2016
1 Content Page 2 Overview Page 8 BD Series Base panel air/dirt eliminator Page 9 BS Series Base panel hydraulic separation Page 10 ZV Series Base panel with zone valves Page 11 DR Series Radiant add-on panel with outdoor reset mixing valve Page 12 DRD Series Radiant add-on panel with setpoint mixing valve Page 14 DS Series Add-on panel for circulator zones Page 15 DZV Series Add-on panel for zone valves Page 16 Page 17 Page 20 Page 21 Page 22 Page 23 HX Series Circulator Selection Zone Valve Control Switching Relay Zone Sentry Zone Valve iseries MixingValve
2 Hydronic Assemblies Inc. Hydronic Mechanical Panel System Hydronic Assemblies Inc. (HAI) mechanical panels are designed for the professional hydronic heating and cooling technicians. These panels are piped just like the pros do it in the field. They are preassembled; pressure tested and prewired on a rugged powder coated plate steel platform that promotes speed and quality of the installation. We use common parts and components for familiarity and ease of service. The system consists of a starter/base panel and add-on distribution panels. Choose between hydraulic separation and air/dirt eliminator for your starter panel and then add the appropriate add-on panel to complete your near boiler piping. Multiple circulator choices for each panel ensures full customization to meet the project zone requirements. Base Panels BD Series: This base panel has an air/dirt eliminator, zone control, 2-1 pumped zones. It is typically used with an oil boiler, modulating gas boiler with hydraulic separation, distribution side of a buffer tank or any heat/cool source where hydraulic separation is not required. Standard circulators have high efficiency ECM motor designs. BS Series: This base panel has a hydraulic separator, zone control, source side pump, fill & vent, expansion tank tee, air vent, dirt drain and 2-1 pumped zones. The BS Series is typically used with a modulating gas boiler without hydraulic separation, air to water heat pump, water to water heat pump (Geothermal) and any other heat/cool source where hydraulic separation is required. Standard circulators have high efficiency ECM motor designs. BS-ZV Series: This base panel has a hydraulic separator, zone control, source side circulator, fill & vent, expansion tank tee, air vent, dirt drain and a distribution circulator with 2 Zone Valve
3 controlled zones. This is the most efficient panel system and consumes much less energy than systems with circulator zones. BD-ZV Series: This base panel has an air/dirt eliminator, zone control, source side pump and a distribution side circulator with 4 Zone Valve controlled zones. This is the most efficient panel system and consumes much less energy than systems with pumped zones Base Panel Construction 12 gauge steel with structural reinforcing bends and mounting holes Dimensions Width - 41 Height - 34 3/8 Depth - 10 ½ Powder coated white matte finish 1 ¼ main plumbing connections 1 Zone connections Distribution Panels DR Series: The DR distribution panel is a radiant panel designed to be combined with a base panel. The DR panel has a Taco 3 way valve with outdoor reset control and 2 1 zones with circulators. This panel can be used in any pumped zone application that requires a mixing control such as, baseboard heat, fan convectors, hydro air, DHW, radiators and radiant heat. The DR panel will utilize either the control on the Base Panel or the SR504-4 EXP control located on the DRC Distribution Panel (see Base Panel and Distribution Panel control selections). Standard circulators have high efficiency ECM motor designs. DS Series: The DS distribution panel, which is added to a base panel, has 2 1 zones with circulators. This panel can be used in any pumped zone application such as, baseboard heat, fan convectors, hydro air, DHW, radiators and radiant heat if no mixing valve is required. This panel
4 will utilize the zone controller of the Base Panel. Standard circulators have high efficiency ECM motor designs. HX Series: The HX Series panel is a stand-alone panel that provides absolute system isolation when connecting an anti-freeze loop with the home water based hydronic system. A typical application would be connecting a Monobloc Air>Water Heat Pump system to the homes water based system. This panel ideally suited for connecting heat pump system to a buffer tank. The panel utilizes a Taco SR504-4 relay to control the panel pumps. Standard circulators have high efficiency ECM motor designs. ZV Series: The ZV distribution panel is a complete 2 zone addition to the ZV Base panels. The ZV Series panel has 2 1 zones with zone valves on the distribution supply piping. The ZV panel will utilize the Taco ZVC404-4 zone valve controller located on the ZV Base panel. This panel is perfect for gas boilers, oil boilers and Air > water HPs. circulators have high efficiency ECM motor designs. Distribution Panel Construction 12 gauge steel with structural reinforcing bends and mounting holes Dimensions Width 18 ¾ Height - 34 3/8 Depth - 10 ½ Powder coated white matte finish 1 ¼ main plumbing connections 1 Zone connections
5 Mix and Match Select the panels you need for a complete prefabricated panelized system. BD Series Base panel DS Series add-on Air/Dirt separation with 4 zones applicable to baseboard, indirect DHW, fan coil, radiant (outdoor reset boiler) BS Series Base panel DR Radiant panel DR radiant panel Hydraulic separation with 1 zone indirect, 1 zone supplemental and 4 zones radiant with 2 temperatures
6 HX series BD Series base panel DR Radiant Panel Air > water HP or atmospheric storage connected to pressurized storage with 1 zone indirect DHW, 1 zone supplemental and 2 zones radiant BSZV Base panel DZV add-on panel Hydraulic separation and four zones utilizing zone valves
7 Panel Selection HAI has provided multiple panel combinations for system type and flow requirements. We recommend panel selection is made with the appropriate system requirements, such as, flow, head, temperature, outdoor reset, etc. The components section contains the circulator performance charts for correct circulator selection. Hydronic Assemblies Inc. takes no responsibility for selection of the individual panels. Panels are connected by soldered couplings.
8 Hydronic Base Panel BD Series Air/dirt eliminator, zone control, and 2-1 pumped zones. The BD Series is typically used with an oil boiler, modulating gas boiler with hydraulic separation, distribution side of a buffer tank or any heat/cool source where hydraulic separation is not required. Standard circulators have high efficiency ECM motor designs. Configurations Model number BD200 BD204 BD201 1 Zone Circulators Taco VR1816-HY1-FC2A00 Taco VT2218FS Taco 007-F5-8IFC Control: Taco SR504-4 4 zone circulator control Control Option: Taco SR506-4 Additional Features: Pressure tested - Pressure testing port with pressure gauge included Prewired - Integral flow checks on all circulators Legend T-88 Air and Debris eliminator with fill system including backflow preventer and expansion tank attachment point
9 BS Series Hydraulic separator, zone control, source side pump, fill & vent, expansion tank tee, air vent, dirt drain and 2-1 pumped zones. The BS Series is typically used with a modulating gas boiler without hydraulic separation, air to water heat pump, water to water heat pump (Geothermal) and any other heat/cool source where hydraulic separation is required. Standard circulators have high efficiency ECM motor designs. Configurations Model number Source side circulator 1 Zone Circulators 1 ¼ BS200 Taco VR1816-HY1-FC2A00 Taco VR1816-HY1-FC2A00 BS211 Taco 007-F5-8IFC Taco 007-F5-8IFC BS204 Taco VR1816-HY1-FC2A00 Taco VT2218FS BS201 Taco VR1816-HY1-FC2A00 Taco 007-F5-8IFC Control: Taco SR504-4 4 zone circulator control Control Option: SR506-4 6 zone circulator control Additional Features: Pressure tested -Pressure testing port with pressure gauge included Prewired - Integral flow checks on all circulators - Legend HS-808 hydraulic separator
10 ZV Series There are two simple Zone Valve Base Panels to fulfill project requirements. ZV-001 has a hydraulic separator, zone valve control, one source side circulator and two distribution side 1 zone valves. The ZV-001 is designed for use with any heat/cool source that requires hydraulic separation. ZV-002 has an air/dirt separator, zone valve control, one system circulator and four (4) 1 zone valves. This is a complete system panel for projects up to 4 zones and can be expanded by adding a DZV-003 2 zone add-on distribution panel. ZV-002 ZV-001 Model # Source side Distribution side Zone Valves circulator circulator ZV001 Hydro Sep Taco VR1816 Taco VR1816 Taco Z100C2-1 2 each ZV002 Air/dirt Taco 0013 Taco VR1816 Taco Z100C2-1 4 each Control: Taco ZVC406-4 6 zone circulator control Control Option: none Additional Features: Pressure tested -Pressure testing port with pressure gauge included Prewired - Integral flow checks on all circulators - Legend HS-808 hydraulic separator
11 Radiant Distribution Panel DR Series The DR distribution panel, which is added to a base panel, has a Taco 3 way valve with outdoor reset control and 2 1 zones with circulators. This panel can be used in any pumped zone application that requires a mixing control such as, baseboard heat, fan convectors, hydro air, DHW, radiators and radiant heat. The DR panel will utilize the Base Panel circulator relay control for circulator operation. Standard circulators have high efficiency ECM motor designs. A three way valve with electronic mixing and outdoor reset provide precise temperature control for efficient radiant operation. Configurations DR000 DR001 DR002 Model # 1 Zone Circulators X 2 Taco Viridian VT2218 Taco Viridian VR1816 Taco 007 IFC Control: DR Series will utilize the Base Panel. Mixing Valve: The DR series panel utilizes the Taco I100U3R-1 3 way mixing valve with integral outdoor reset temperature control. The direct drive actuator modulates the 3-way valve that injects different rates of hot water, supplying virtually any water temperature to the heating system. Working off an adjustable reset ratio, the valve s maximum and minimum system supply temperatures can be adjusted to support all types of radiant applications. Additional Features: Pressure tested integral flow checks
12 Radiant Distribution Panel DRD Series The DRD distribution panel, which is added to a base panel, has a manual Taco 3 way valve and 2 1 zones with circulators. This panel can be used in any pumped zone application that requires a mixing control such as, baseboard heat, fan convectors, hydro air, DHW, radiators and radiant heat. The DR panel will utilize either the control on the Base Panel or the SR504-4 EXP control located on the DRD Distribution Panel (see Base Panel and Distribution Panel control selections). Standard circulators have high efficiency ECM motor designs. Panel Construction 12 gauge steel with structural reinforcing bends and mounting holes Dimensions Width - 39 ¼ Height - 34 3/8 Depth - 10 ½ Powder coated white matte finish 1 ¼ main plumbing connections
13 Configurations Model # 1 Zone Circulators X 2 DRD000 Taco VT2218 DRD001 Taco Viridian VR1816 DRD002 Taco 007 IFC DRD003 Taco 0013 Control DRD Series will utilize either the Base Panel control or it will utilize the SR504-4 EXP located on a controlled Distribution Panel. Note: The base panel selected must also have the Taco EXP control when adding a controlled distribution panel. Mixing Valve The DRD series panel utilizes the Taco 3 way mixing valve with a downstream thermometer for temperature readings. This simple distribution panel works well for applications where a fixed circulation temperature is acceptable. Additional Features Pressure tested Integral flow checks
14 Hydronic Distribution Panel DS Series The DS distribution panel, which is added to a base panel, has 2 1 zones with circulators. This panel can be used in any pumped zone application such as, baseboard heat, fan convectors, hydro air, DHW, radiators and radiant heat if no mixing valve is required. This panel will utilize the zone controller of the Base Panel. Standard circulators have high efficiency ECM motor designs. Configurations DS000 DS001 DS002 Model # 1 Zone Circulators X 2 Taco VT2218 Taco Viridian VR1816 Taco 007 IFC Control DS Series utilizes the Base Panel circulator control Additional Features Pressure tested Integral flow checks on all circulators
15 Hydronic Distribution Panel DZV Series The DZV-003 distribution panel, which is added to the BZV-001 or BZV-002 Base Panel, has 2 1 Zone Valve controlled zones. This panel can be used in any pumped zone application such as, baseboard heat, fan convectors, hydro air, DHW, radiators and radiant heat if no mixing valve is required. This panel will utilize the zone valve controller of the BZV-001 or BZV-002 Base Panel. Control DZV-003 Series utilizes the ZV-001 or ZV-002 Base Panel zone valve control Additional Features: Pressure tested Prewired to connect with the Base Panel
16 Heat Exchanger Panel HX Series The HX Series panel is a stand-alone panel that provides absolute system isolation when connecting an anti-freeze loop with the home water based hydronic system. A typical application would be connecting a Monobloc Air>Water Heat Pump system to the homes water based system. This panel ideally suited for connecting heat pump system to a buffer tank. The panel utilizes a Taco SR504-4 relay to control the panel pumps. Standard circulators have high efficiency ECM motor designs. Configurations Model # Source side circulator Taco FTP 5 X 12 X 30 plate Distribution side circulator HX001 Taco 0013 30 plate HX Taco VR1816 HX002 Taco VR1816 30 Plate HX Taco VR1816 Control: Taco SR504-4 circulator relay Heat Exchanger: Taco FTP 5 x 12 x 30 plate heat exchanger with 1 ¼ ftgs Additional Features: Pressure tested - Pressure testing port with pressure gauge included Prewired - Integral flow checks
17 Circulator Selection Taco VT2218: The TACO Viridian VT2218 comes with two temperature sensors to provide Delta-T readings to the pump's controller. The Viridian VT2218 circulator is a temperature sensing, self-adjusting, variable speed wet rotor circulator with an ECM permanent magnet motor. Operating modes include Delta-T differential temperature, 4 fixed speeds, set point heat, set point cool and boiler protection. Typical uses include hydronic systems zoned with zone valves, radiant loops, injection pumping, snow-melt or hydro-air fan coils. It can also be used in constant speed mode for zoning with circulators, indirect water heaters or primary boiler loops.
18 Taco Viridian VR1816 The Viridian VR1816 circulator is an infinitely variable speed, high-efficiency wet rotor circulator with an ECM permanent magnet motor. Operating modes include infinitely variable fixed speed to fine tune any zone, self-adjusting constant pressure for zone valve applications and selfadjusting proportional pressure for panel radiators with thermostatic radiator valves. It s simple to install and intuitive to set up. An LED displays operating mode, error codes diagnostics and Sure Start automatic activation. The Viridian uses up to 85% less energy than circulators without ECM technology. Taco VR1816
19 Taco 0013 The high-performance Taco 0013 3-Speed circulator is designed for high-head/high-flow, large residential/light commercial hydronic heating and chilled water cooling systems. The 3-Speed switching ability lets you fine tune the performance to match a wide range of applications. Taco 007 IFC: The Taco 007 is a cartridge style, maintenance free, wet-rotor, in-line, single stage circulator pump. It is designed for quiet operation in Hydronic heating, Radiant heating, Hydro-Air fan coils, Indirect water heaters, Chilled fresh water, and Domestic Water Recirculation systems. Note: Circulator performance curves and circulator description courtesy of Taco Inc...
20 Zone Valve Control Simplify the wiring nightmare! Taco Zone Valve Controls easy-to follow PC board layout eliminates the problems caused by incorrect wiring, while the external indicator lights provide instant diagnostic feedback. Combined with Taco Zone Valves and Thermostats, the system s performance and dependability is maximized. Zone Valve Controls Taco Zone Valve Controls work with two-, three-, or four-wire zone valves. Fully fuse protected, they also include two isolated end switches and built-in priority protection. The contractor friendly PC board layout eliminates the problems caused by incorrect wiring and the unfinished look of conventional zone valve installations. The sturdy screw connections add additional reliability, while the external indicator lights provide instant diagnostic feedback, reducing installation time. All Taco Zone Valve Controls are UL listed and carry an extended 3 year warranty. Taco Expandable Zone Valve Controls Whether you want to expand up to 120 zones or utilize the advanced features of the Add-on Power Controls, Taco -EXP controls allow for simple integration of advanced features. Built-in Post Purge and Pump Exercise functions can optimize the operation of any system.
21 Circulator Switching Relay The Taco Switching Relay is the best choice for all your zoning needs, with advanced timer and boiler functions, external diagnostic lights, switchable priority and contractor friendly PC board layouts. Combined with the time proven reliability of the 00 family of circulators and thermostats, total system integration is achieved. Switching Relays Taco Switching Relays combine clearly labeled PC board layouts with advanced features that allow for total system customization. Whether using basic priority switching or the advanced features of the -EXP controls, the job is made easy. External indicator lights provide instant diagnostic feedback, making a snap of service calls or new installation start-ups. All switching relays are UL listed, are compatible with conventional and programmable thermostats. Taco Expandable Switching Relays Whether you want to expand up to 120 zones or utilize the advanced features of the Add-on Power Controls, Taco -EXP controls allow for simple integration of advanced features. Built-in Post Purge and Pump Exercise functions can optimize the operation of any system.
22 Zone Sentry Zone Valve The Taco Zone Sentry Zone Valve enhances the overall performance of any zone valve system. The unique patented technology in the Zone Sentry utilizes microcircuit based logic to control a gear driven electronic actuator which drives a ball valve based body design. All this adds up to a zone valve that leads the industry in energy efficiency, flow capacity (C v ), shutoff pressure rating, ease of installation, diagnostic capability and the number of valves (12) that can be use on a standard 40VA transformer. Taco Zone Sentry zone valves are available in sweat, threaded, 3/4 Press Connection, Inverted Flare 3/4 sweat and 3-way configurations. Application: Taco Zone Sentry Zone Valves provide on-off, normally open or normally closed control in both open and closed hydronic systems. The valves can be used in a wide variety of heating and non-condensing cooling applications, primarily designed for use with baseboard, fan coils, radiators, convectors, air handlers, heat pumps and radiant applications. Ease of Installation / Operation: The Taco Zone Sentry is the most technologically advanced zone valve ever made. It s also simple to install and operate. The valve can be installed in any direction, in any orientation. We then went a step further, allowing the operator to be mounted to the 2-way valve body in either direction, great for those tight baseboard jobs. Snap-in quick connects on the back of the valve make for a simple, secure and fast wiring hook-up. A green LED light shows full functionality of the valve s operation and thermostat status. Under a no power situation the manual override button located on the top of the valve allows the ball to be rotated up to 90 and is also marked with a slot to indicate the position of the valve.
23 iseries MixingValve Taco iseries Mixing Valves are a breakthrough in precision, cost effective temperature control for heating systems. The iseries valves are available in two versions, providing either outdoor reset control or fixed water supply temperature by modulating the position of a 2-way, 3-way or a 4-way valve. Additionally, iseries valves protect the boiler against flue gas condensation. A microprocessor-based control is built into the valve actuator, to which all wiring connections are made. All-in-one iseries Mixing Valves deliver optimum zone-by-zone temperature control, with built-in boiler protection. Outdoor Reset Application: Use the Taco Outdoor Reset iseries Mixing Valves instead of a conventional injection system. With a full featured outdoor reset control built right into the actuator there is no need for an externally mounted reset control or expensive control valve. The iseries valves can also be set up to do zone-by-zone outdoor reset, providing optimal comfort control for every zone. New 3-way ivalve with union connections makes for an easy change-out of any thermo- static mixing valve. Instantly improve the comfort and energy efficiency of any job by dropping in an Outdoor Reset ivalve in place of any fixed temperature mixing valve. The direct drive actuator modulates a 2-way, 3-way or 4-way valve that injects different rates of hot water, supplying virtually any water temperature to the heating system. Working off an
24 adjustable reset ratio, the valve s maximum and minimum system supply temperatures can be adjusted to support all types of jobs, including staple-up radiant floors that require a higher starting temperature. The iseries valves include an adjustable boiler protection function which prevents low water temperatures from returning to the boiler. With a multi-status LED indicator light, plug-in wiring connections and an easy to remove actuator, the installation could not be easier. Setpoint Application: Use the Taco Setpoint iseries Mixing Valves instead of a thermostatic mixing valve for precise dial-in temperature control to a heating system. In combination with the optional boiler protection sensor, the iseries valves provide the unique benefit of optimal temperature control with boiler protection. The setpoint temperature is adjustable from 80 F to 180 F using a dial located on top of the actuator. A 15 F setback of the supply water can be initiated for additional unoccupied or nighttime setback control. An external multi-status LED indicator light, plug-in wiring connections and an easy to remove actuator makes installation and diagnostics a snap.