SPCIICATIOS Model HWP 118RKTY Item o. (Standard/Opposite Hand) 510-118-001 / 510-118-011 Cooling capacity (net) to AS/ZS 3823 T1 11.9 kw Heating capacity H1 11.6 kw lectrical input - cooling 2.9 kw lectrical input - heating 2.9 kw R / AR (cooling) 4.17 / 4.16 COP / ACOP (heating) 3.92 / 3.91 Unit Controller UC8 Refrigerant R410A Refrigerant charge 2.0 kg Compressor type rotary connections 3/4" male BSP ominal WT on cooling 30 C ominal WT on heating 21 C ominal low @ WT LWT = 5k 0.75 l/s ntering system pressure drop @ nominal flow 55 kpa (8 psi) Min. water temp. Heat cycle at nominal flow 10 C Min. water temp. Cool cycle at nominal flow 15 C Min. water temp. Cool cycle with water regulating valve 5 C Max. WT Heat cycle at nominal flow 30 C Max. WT Cool cycle at nominal flow 50 C Min. water flow @ nominal WT 0.21 l/s Max. water pressure excluding hoses 3200 kpa (464psi) Power supply 3 ph. 40 ac 50Hz Compressor run amps at rating cond. 4.1 A/ph. Indoor fan motor size 600 W (C) Indoor fan motor (1ph.) - full load 3.1 A Control circuit breaker (internal) 10 A Running amps (total system) 4.9 / 4.1 / 4.1 A Max. running amps (total system) 9.6 / 6.3 / 6.3 A et weight 118 kg Accessories: Spring mounts supplied hoses 600mm long, rated 1720 kpa (250psi) 3/4" female BSP, supplied Replacement filter - rated U2/G2 119-000-097 763x328x13 Condensate lift-pump 507-003-010 Optional: SAT-3 Room temperature controller 201-000-146 TZT-100 Room temperature controller 201-000-350 Refer to temperzone for other options, eg remote sensors Tested in accordance with AS/ZS 3823 16054
DIMSIOS (mm) PROJCTIO HWP 118RKTY Standard ot to Scale W lectrical Box X POIT LOADS (kg) W X Y Z 21 20 40 36 ote: an motor can be accessed from panel above, below or sides; no more than two panels at once. Z C Motor Driver Y 63 HWP 118RKTY Opposite Hand POIT LOADS (kg) W X Y Z 63 W lectrical Box X 20 21 36 40 ote: an motor can be accessed from panel above, below or sides; no more than two panels at once. Z Y C Motor Driver OT Specifications are subject to change without notice due to the manufacturer's ongoing research and development programme.
LCTRICAL TH2 TH3 TH4 TB1 TB2 TB3 TBL2W1 TB4 L1 TH4 CC-1260 TB5 L2 TH5 TB6 L3 xternal Protection & Isolation 1-C A SRB Optional 0-1 controls PRC CCB 1-C B 24VAC/12VDC controls /C COM PRR PCC PRR Pump Verification Dry Contacts Modbus slave port for BMS (monitoring or control) RB 5-B A /C COM CM 5-C B TB7 low 1 low 2 Modbus master port for optional T/stat (TZT100/SAT-3) 1 If Pump Verification Option fitted remove this link 3-D 2RB 2 Condensate Pump 0-1 to Regulating Valve Relay 2 COM 2 C 5- errite- coil 2 turns Yellow Yellow VC 12 V HI M LO C1 5 I#2 I#2 I#1 I#1 C2 HT CP Red White B1 A1 AUX XV2 XV1 J1 UC8 Refer to DIP S/W settings LT 12 B2 A2 J2 SW1 SW2 Temp Sensors (Refer to table) DP1 DL SL Display errite- coil 3 turns Separate these 3 wires from all others wires & circuit boards. IM V1 V2 DI AMB SW3 OC IC CP4W1 low COM Control Valve /C 5- D Relay 1 TB8 Pump 1 Pump 2 D1 D2 Pressure sensors HPT LPT Active CC driver located opposite main box -2-2 If Condensate loat Switch Option fitted remove this link D3 SC C3 LOW MD HIGH CP2W1 SSR2 SSR2 SSR1 SSR1 R/V R/V Condensate loat Switch (ormally closed) O L C4 errite- coil 5 turns Remote On/Off Dry Contact If Remote On/Off option fitted remove this link C D errite- coil 5 turns through ferrite core. Red or White LCTRIC ILTR Green/Yel Red or White UC8 JUMPR settings TB9 ACTIV Position Jumper RV B-7 J1 J2 CC C MOTOR COROLLR LCTRICAL ILTR TH ARTH RB AULT RLAY BOARD IM IDOOR A MOTOR AC ACL UC8 DIP switch settings B-7 PCC POWR ACTOR CORRCTIO CAPACITOR PRC PHAS ROTATIO COTROLLR CCB COTROL CIRCUIT BRAKR PRR PHAS ROTATIO RLAY CM COMPRSSOR MOTOR SRB STATUS RLAY BOARD COMPRSSOR COTACTOR RV RVRSIG VALV CP2W COCTOR PLUG 2 WAY TB TRMIAL BLOCK CP4W COCTOR PLUG 4 WAY TBL2W TRMIAL BLOCK LIK 2 WAY 2RB XV2 RLAY BOARD UC8 UIT COTROLLR 8 Title: Drawing o: Rev: 291-000-867 A DIP switch On/Off 1,6,13,14 On All Others Off Off Sensors (S) / Transducers (T) ame Type Colour DL Discharge Temp S RD SL Suction Temp S WHIT APPROVD DAT C RV DSCRIPTIO A Initial Release IC Indoor Coil S YLLOW HPT High Pressure T C.M.W. Date: 04-04-16 Drawn: temperzone Ltd 2016 Client Wiring SHT 1 O 1 HWP 118RKTY UC8 Wiring Schematic Apprvd: DO OT SCAL - ASK
003-000-064 09/16 www.temperzone.biz temperzone limited 2016
SPCIICATIOS Model HWP 118CKTY Item o. (Standard/Opposite Hand) 510-118-102 / 510-118-112 Cooling capacity (net) to AS/ZS 3823 T1 11.9 kw Heating capacity - lectric heat 6.0 kw lectrical input - cooling 2.9 kw lectrical input - heating 6.3 kw R / AR (cooling) 4.17 / 4.16 Unit Controller UC8 Refrigerant R410A Refrigerant charge 1.78 kg Compressor type rotary connections 3/4" male BSP ominal WT on cooling 30 C ominal low @ WT LWT = 5k 0.75 l/s ntering system pressure drop @ nominal flow 55 kpa (8 psi) Min. water temp. Cool cycle at nominal flow 15 C Min. water temp. Cool cycle with water regulating valve 5 C Max. WT Cool cycle at nominal flow 50 C Min. water flow @ nominal WT 0.21 l/s Max. water pressure excluding hoses 3200 kpa (464 psi) Power supply 3 ph. 40 ac 50Hz Compressor run amps at rating cond. 4.1 A/ph. Indoor fan motor size 600 W (C) Indoor fan motor (1ph.) - full load 3.1 A Control circuit breaker (internal) 10 A Running amps (total system) 1.4 / 13 / 13 A Max. running amps (total system) 9.6 / 13 / 13 A et weight 117 kg Accessories: Spring mounts supplied hoses 600mm long, rated 1720 kpa (250psi) 3/4" female BSP, supplied Replacement filter - rated U2/G2 119-000-097 763x328x13 Condensate lift-pump 507-003-010 Optional: SAT-3 Room temperature controller 201-000-146 TZT-100 Room temperature controller 201-000-350 Refer to temperzone for other options, eg remote sensors Tested in accordance with AS/ZS 3823 15054
DIMSIOS (mm) PROJCTIO HWP 118CKTY Standard ot to Scale W lectrical Box X POIT LOADS (kg) W X Y Z 21 20 40 36 ote: an motor can be accessed from panel above, below or sides; no more than two panels at once. Z C Motor Driver Y 63 HWP 118CKTY Opposite Hand POIT LOADS (kg) W X Y Z 20 21 36 40 63 W lectrical Box X ote: an motor can be accessed from panel above, below or sides; no more than two panels at once. Z Y C Motor Driver OT Specifications are subject to change without notice due to the manufacturer's ongoing research and development programme.
LCTRICAL Visit http://www.temperzone.biz for client wiring schematics TH2 TH3 TH4 TB1 TB2 TB3 TBL2W1 TB4 L1 TH4 CC-1260 TB5 L2 TH5 TB6 L3 xternal Protection & Isolation 1-C A SRB Optional 0-1 controls PRC CCB 1-C B 24VAC/12VDC controls /C COM PRR PCC PRR Pump Verification Dry Contacts Modbus slave port for BMS (monitoring or control) RB 5-B A /C COM CM 5-C B TB7 low 1 low 2 Modbus master port for optional T/stat (TZT100/SAT-3) 1 If Pump Verification Option fitted remove this link HC1 HC2 H1 H2 errite- coil 2 turns Yellow Yellow VC 12 V HI M LO C1 5 I#2 I#2 I#1 I#1 C2 HT CP Red White B1 A1 AUX XV2 XV1 J1 UC8 Refer to DIP S/W settings LT 12 B2 A2 J2 SW1 SW2 Temp Sensors (Refer to table) DP1 DL SL Display 3-D 2RB 2 Condensate Pump 0-1 to Regulating Valve Relay 2 errite- coil 3 turns Separate these 3 wires from all others wires & circuit boards. COM 2 C 5- IM V1 V2 DI AMB SW3 OC IC CP4W1 low COM Control Valve /C 5- D Relay 1 TB8 Pump 1 Pump 2 D1 D2 Pressure sensors HPT LPT Active If Condensate loat Switch Option fitted remove this link CC driver located opposite main box -2-2 D3 SC C3 LOW MD HIGH CP2W1 SSR2 SSR2 SSR1 SSR1 R/V R/V Condensate loat Switch (ormally closed) O L C4 errite- coil 5 turns Remote On/Off Dry Contact If Remote On/Off option fitted remove this link HST C t D errite- coil 5 turns through ferrite core. Red or White LCTRIC ILTR Green/Yel Red or White UC8 JUMPR settings HC2 MST TB9 ACTIV Position Jumper LCTRICAL ILTR H LCTRIC HAT HC LCTRIC HAT COTACTOR TH TH RB AULT RLAY BOARD HST HIGH TMPRATUR SATY THRMOSTAT t B-7 HC1 AC J1 J2 ACL B-7 UC8 DIP switch settings IM IDOOR A MOTOR MST MAUAL SATY THRMOSTAT CCB COTROL CIRCUIT BRAKR PCC POWR ACTOR CORRCTIO CAPACITOR CM COMPRSSOR MOTOR PRC PHAS ROTATIO COTROLLR COMPRSSOR COTACTOR PRR PHAS ROTATIO RLAY CP2W COCTOR PLUG 2 WAY SRB STATUS RLAY BOARD CP4W COCTOR PLUG 4 WAY TB TRMIAL BLOCK 2RB XV2 RLAY BOARD TBL2W TRMIAL BLOCK LIK 2 WAY CC C MOTOR COROLLR UC8 UIT COTROLLR 8 Title: Drawing o: Rev: 291-000-783 A Sensors (S) / Transducers (T) DIP switch On/Off 1,3,4,6,13,14 On All Others Off Off ame Type Colour AMB ast Temp Sensor S BLACK DL Discharge Temp S RD SL Suction Temp S WHIT IC Indoor Coil S YLLOW HPT High Pressure T APPROVD DAT C RV DSCRIPTIO A Initial Release C.M.W. Date: 04-04-16 Drawn: temperzone Ltd 2016 Client Wiring SHT 1 O 1 HWP 118CKTY UC8 Wiring Schematic Apprvd: DO OT SCAL - ASK
003-000-063 09/16 www.temperzone.biz temperzone limited 2016