McQuay. Self-Contained Variable and Constant Air Volume. SWP Vintage G. Replacement Parts List No Revision C 09/2018

Similar documents
McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 020, 025 Vintage E. Replacement Parts List No Revision J 02/2018

McQuay. Maverick II Commercial Packaged Rooftop Cooling and Heating. MPS 030, 035, 040, 050 Vintage A, E

Air Cooled Scroll Compressor Condensing Unit

McQuay. Roofpak Roof Mounted Air Handler Draw- Through. RDS Size: 900 Vintage: B. Last Manufactured: 1998

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage A. Replacement Parts List No Revision E 04/2016

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

McQuay. Commercial Unitary Rooftop. CUR Vintage G. Last Manufactured: Replacement Parts List No Revision A 11/2016

Daikin McQuay. Templifier Scroll Compressor Water Heater. TGZ Vintage B. Replacement Parts List No Revision F 11/2017

Installation Manual IM

MEA. Self-contained Air Conditioning System. Installation and Maintenance. Type SWT C Vintage Sizes 18 thru 40. Group: Applied Systems

AAF. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. Last Manufactured: Replacement Parts List No Revision D 08/2016

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW, UC, UG, UW Vintages E, F, G. Last Manufactured: 1988

Daikin McQuay. Roofpak Evaporative Condensing Units. RPE, RDE Tons Vintage C. Replacement Parts List No Revision K 07/2016

Self-Contained Air Conditioning System

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 007, 009, 012 Design 1. Replacement Parts List No Revision M 11/2017

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 015, 019 Vintage A. Last Manufactured: 1993

VariCool VAV Engineering Guide

Daikin McQuay. Incremental. PKEI, PKES, PKHS Design 2. Replacement Parts List No Revision A 07/2017

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991

McQuay. Ceiling Concealed Horizontal Water Source Heat Pump. CCH, CCG, CCW 048, 060 Vintage A. Last Manufactured: 1995

McQuay. Enfinity Vertical Water Source Heat Pump. WFCV, WFCW Design 1. Replacement Parts List No Revision D 03/2018

Daikin McQuay. Pathfinder Air Cooled Chiller Screw Compressor Two Circuit. AWS Vintage A

McQuay. Concealed Ceiling Water Source Heat Pump. WCAE, WCAS, WCDA, WCDL, WCDS, WCMS 024, 030 Design A (1)

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision O 11/2017

Daikin McQuay. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 1. Replacement Parts List No Revision R 11/2018

Installation and Maintenance Manual IM 988-1

McQuay. Console Water Source Heat Pump. WWDU Design A. Last Manufactured: Replacement Parts List No Revision A 07/2017

Daikin. Enfinity Console Water Source Heat Pump. WMHC, WMHW 015, 018 Design 2. Replacement Parts List No New 11/2017

McQuay. Screw Chiller Water Cooled. WHS Vintage A. Last Manufactured: Replacement Parts List No New 07/2012

Daikin Daikin McQuay. Pathfinder Screw Compressor Air Cooled Chiller 2 Circuit. AWS Vintage: C Unit Revision 00 (Code 62)

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994

MEA. Self-Contained Air Conditioning System. Installation and Maintenance. Type SWP Vintage Sizes 18 through 95, 105. Group: Applied Systems

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015

Daikin McQuay. Pathfinder Screw Compressor Air-Cooled Chiller 3 Circuit. AWS Vintage B Unit Revision 0B (Code 62)

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW 036, 042 Vintage A. Last Manufactured: 1993

McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone. RCS Tons Vintage C Code 12= 1A, 2A. Valid for units built 06/2010 & Earlier

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)

Daikin. Self-Contained Unit Ventilator. UAEQ 036, 044, 054 Design H (8) Replacement Parts List No New 11/2017

McQuay. Large Vertical Water Source Heat Pump. LGP, LHP, LWP Vintage C. Last Manufactured: 1994

McQuay. Self-Contained Unit Ventilator. UAZQ, UAZR, UAZU Design G (7) Replacement Parts List No Revision D 08/2018

Self-contained Air Conditioning System

AIR HANDLER DESIGN WORK SHEET

McQuay. Water Source Heat Pump Ceiling Mounted. CCW Vintage E. WCDD, WCDE, WCMG Design A (1) WCDD, WCDE Design B (2)

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

Water Cooled Screw Chiller PFS235C, PFS255C, PFS270C, PFS280C, PFS300C, PFS315C PL

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

REPLACEMENT PARTS LIST

VertiCool Aurora Engineering Guide

McQuay. Seasonmaker ThinLine Horizontal Fan Coil. TSH, TSC Vintage F. FTSH, FTSC Designs A(1), B(2) Last Manufactured: 2008

VERSECON Indoor Vertical Self-Contained Air Conditioner YSWU Ton Water-Cooled

Modular Supply Make-Up Air Unit

Daikin Navigator. Water-Cooled Screw Compressor Chiller. WWV JNNS, MNNS, RNNS Vintage A. Replacement Parts List No Revision A 02/2018

McQuay BACnet Solution: Microtech II Self-contained Unit Controller with Discharge Air Control (DAC)

Daikin. Trailblazer Air-Cooled Scroll Chiller. AGZ 190, 210, 225, , 211, 226, 241 Vintage E Unit Revision 00

Field Start-Up Sheet Direct Fired Gas Equipment

Parts List. Modular Crescent Cuber. Models KM-901MAJ KM-901MWJ KM-901MRJ/3. hoshizakiamerica.com

VertiCool CLASSIC. Engineering Guide. Effective March Air-Cooled, Water-Cooled, Chilled Water and Water Source Heat Pump

CeilMate TM Series 3 and 4 tons of cooling capacity. Ceiling Mounted Systems. Air Handler with Remote Condensing Unit Air Handler designed for R-410A

SECTION WATER-SOURCE UNITARY HEAT PUMPS

REPLACEMENT PARTS LIST

Complete HVAC Capability. Central Station Air Handling Units. Publication No. WT-CSX-0616A

McQuay Acson. Ductless Split System Indoor Ceiling Cassette ACK-A, ACK-AR MCK-A, MCK-AR Last Manufactured: 2007

Mammoth Water Source Heat Pumps

Installation Instructions

RoofPak Singlezone Roof Mounted Heating and Cooling Units

Climate Control Singer. Incremental Comfort Systems. KS, EKS Vintage B. Last Manufactured: 1982

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION FEATURES L4EU NOMINAL TONS

VCM-X Controller Technical Guide

WE ARE PLEASED TO PROVIDE THE ENCLOSED SUBMITTAL FOR YOUR REVIEW AND APPROVAL

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

Submittal Summary Page

C13-Series Engineering Guide

TECHNICAL GUIDE SPLIT-SYSTEM AIR-COOLED EVAPORATOR BLOWER 25, 30, 40 & 50 TON LA300, LB360, 480 & 600 (50 Hz) PROVEN PERFORMANCE GENERAL FEATURING

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

FAN TERMINAL UNITS Constant Volume (Series Flow), Standard Design

technical guide Water-Cooled Self-Contained Units

RoofPak Singlezone Roof Mounted Heating and Cooling Units

Cabinet Features Heavy-gauge, galvanized-steel cabinet with UV-resistant powder-paint finish Full Perimeter Rail Sloped drain pan

Roof Top Packaged Unit (RTU-1) Specification

Installation, Start-Up and Service Instructions

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

McQuay. Aircon Air Cooled Condenser. AMB, APB AMD, APD Vintage A. Last Manufacture: 1978

Cutting Edge Compressor Technology

SINGLE-PACKAGE ROOFTOP HEAT PUMP UNITS INDEX. VOLTAGE (3 Ph, 60 Hz) ACCESSORIES

Advance Release September 2009

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

Technical Guide SUNLINE 2000 DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWER K4EU NOMINAL TONS (WORLD 50 HZ)

Catalog Air Cooled Split System Condensing Units for Rooftop Systems and Air Handlers

A. American National Standards Institute (ANSI) : Establishes requirements applicable to certifying direct gas-fired heaters.

DANFOSS OPTYMA PLUS INVERTER UNITS

SECTION ROTARY-SCREW WATER CHILLERS

Parts List. Stackable Crescent Cuber. Models KM-1900SAJ/3 KM-1900SWJ/3 KM-1900SRJ/3. hoshizakiamerica.com

CATALOG OF REPLACEMENT PARTS HSROG SERIES SINGLE RACK OVEN. A product of HOBART CORPORATION 701 S. RIDGE AVENUE TROY, OHIO

REPLACEMENT PARTS MANUAL

Parts List. Modular Crescent Cuber. Models KMD-460MAH, MWH KMD-530MAH, MWH, MRH. hoshizakiamerica.com

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Transcription:

Replacement Parts List No. 70009200 Revision C 09/208 McQuay Self-Contained Variable and Constant Air Volume SWP 08-20 Vintage G This RPL is primarily intended for use with General Order (GO) numbers 835060-( ) AND 835067-( ). When selecting parts for units with other GO numbers, confirm the part number(s) required with Daikin Applied before ordering. To find your Daikin Applied parts distributor, call -800-377-2787 or visit www.daikinapplied.com

Table of Contents Parts List Revision History... 3 Model & Serial Number Nomenclature... 4 Unit Model Number Complete... 5, 6 Electrical Legend... 7, 8 Unit Layout Diagram... 9 Controls Control Box Diagram... 0 Control Box Component Label Diagram... Common Control Components... 2, 3 Compressor Contactors and Manual Motor Protectors... 4 Fan Motor Contactor and Motor Protector Configuration Diagrams... 5, 6 Fan Motor Components... 7-9 Disconnect Switches... 20 Refrigeration & Water Components Refrigeration Circuit Layout Diagrams & Components... 2 Condensers & Condenser Components... 22 Water Valve & Actuator... 23 Compressors... 24 Fan Motors & Inverters... 25 Fan Section Fan Assembly Diagrams... 26 Wheels & Shafts... 27 Bearings... 28 Fan Drives... 28 Drive Packages... 29, 30 Seismic Spring Vibration Isolators... 3 Hot Water Heating Coils, Waterside Economizer Coils, & Evaporator Coils Hot Water Heating Coils... 32 Waterside Economizer Coils... 32 Evaporator Coils... 32 Cabinet Door Components... 33 This RPL is primarily intended for use with General Order (GO) numbers 835060-( ) AND 835067-( ). When selecting parts for units with other GO numbers, confirm the part number(s) required with Daikin Applied before ordering. Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 2

Parts List Revision History Revision Date Description NEW 05/ New. A 2/ Page 2: Changed SPS, 2 p/n "04954503" to "9024528" & SPS3 p/n "04954502" to "9024529". Added footnote #3. B 0/8 Cover, Pg. 2, : Rewrote GO Note. Page 4-6: Misc. updates. Page 7, 8: Reformatted the Electrical Legend table. Page 0: Rewrote footnote #. Updated the dwg. Page 2: Misc. updates/corrections. Page 3: Added schematic symbol "S2" p/n & description to table. Page 4: Updated/corrected table. Deleted footnotes 2-4. Page 7-9: Misc. updates/corrections. Rewrote/deleted footnotes. Added 50HP info from Old pg. 20. Page 20: Deleted pg. Moved 50HP info to pg. 9. Repaginated the form & updated the TOC. Page 22 (OLD) 2 (NEW): Rewrote footnote #. Page 23 (OLD) 22 (NEW): Added /2 & Later p/n for Ref # 7. Rewrote/added footnotes. Page 25 (OLD) 24 (NEW): Added Cmpr. Avail. chart. Updated Cmpr. p/ns. Rewrote footnote #. Page 26 (OLD) 25 (NEW): Added Drive Codes to Fan Mtr. table. Updated VFD p/ns. Rewrote footnotes. Page 28, 29 (OLD) 27, 28 (NEW): Deleted footnote #. Page 30 (OLD) 29 (NEW): Rewrote notes for "Fan Drives" & "Drive Packages". C 09/8 Page 20: Updated table. Added dwgs.& footnote. Daikin Applied, 3600 Industrial Park Blvd., P.O. Box 55, Minneapolis, MN 55440 (763) 553-5330 Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 3

Model & Serial Number Nomenclature SWP 023 G Unit Type: SWP = Self-Contained, Water Cooled, Plenum Discharge Vintage Unit Size (Nominal Tons): 08 = 8 Ton 023 = 23 Ton 035 = 35 Ton 040 = 40 Ton 045 = 45 Ton 055 = 55 Ton 065 = 65 Ton 070 = 70 Ton 080 = 80 Ton 05 = 05 Ton 20 = 20 Ton Serial Number Nomenclature FBO U 0 05 048200 Plant Identification FBO = Faribault, MN Sequence Number U = Unit Year of Manufacture 0 = 200 = 20 2 = 202 Month of Manufacture 0 = January 08 = August 02 = February 09 = September 03 = March 0 = October 04 = April = November 05 = May 2 = December 06 = June 07 = July This RPL is primarily intended for use with General Order (GO) numbers 835060-( ) AND 835067-( ). When selecting parts for units with other GO numbers, confirm the part number(s) required with Daikin Applied before ordering. Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 4

SWP***G Unit Model Number Complete 27 AL L BEP YY Y RP S Y 3 6A 0606YYYYYYYY Y 2B HS Code 03 04 05 06 07 08 09 0 2 3 4 5 6 7 025S YY AFFSY YY TY L S YY YY YY WY LH Y YY A 2 A A 8 9 20 2 22 23 24 25 26 27 28 29 30 3 32 33 34 35 36 37 03 Unit Voltage 27= 460/60/3 04 Starting Option AL= Across the Line Start 05 Field Power Connection L= Single Point, Lockable Disconnect (Thru Door) 06 Controls Package Digit L= Lon Mark B= BACNet with MSTP E= BACNet with IP S= Standalone Digit 2 E= Discharge Air Control F= Space Comfort Control Digit 3 P= Purchased Control Panel 07 Special Software YY= No Requirement = 00% Outside Air XX= Special 08 Optional MicroTech Hardware Y= No Requirement A= Power Loss Package (Spring Return Actuators) X= Special 09 Alternate Refrigerants RP= R40A and POE Oil XX= Special 0 Quantity of Refrigeration Circuits S= Independent Circuit for each Compressor Refrigerant Specialties Y= No Requirement P= Power Factor Capacitors (5HP cmprs. only) 2 Inverter Y= No Requirement 3= ABB With Bypass S= Schneider w/o Bypass X= Special 3 Cooling Coil Selection 6A= 6 Row 2 FPI AL Fin, Galv. Casing 6B= 6 Row 2 FPI AL Fin, SSTL Casing 6S= 6 Row 2 FPI AL Fin, SSTL Casing XX= Special 4 Compressor Selections Digit -2, 3-4, 5-6, 7-8 09= 9HP Compressor 0= 0HP Compressor 2= 2HP Compressor 5= 5HP Compressor YY= No Requirement XX= Special Digit 9-0, -2 2= 2HP Compressor 5= 5HP Compressor 24= (2) 2HP Compressors 30= (2) 5HP Compressors YY= No Requirement XX= Special 5 Filters R= 2" 30% Pleated X= Special 6 Fan Selection Digit -2 2= 2" Fan 5= 5" Fan 8= 8" Fan 20= 20" Fan 22= 22" Fan 25= 25" Fan 27= 27" Fan 30= 30" Fan 33= 33" Fan 37= 37" Fan 40= 40" Fan Digit 3 = Single Fan Digit 4 B= Air Foil Fan with Single Width Plenum 7 Fan Motor Selection H*= 3HP; J*= 5HP; K*= 7.5HP; L*= 0HP; M*= 5HP; N*= 20HP; P*= 25HP; Q*= 30HP; R*= 40HP; S*= 50HP *S= Premium Efficiency ODP Motor 8 Fan Motor Drive Selection ****S= (****)= Fan RPM/ S= Std. Fixed Drive ****F= (****)= Fan RPM/ F= 50% Fixed Drive 9 UV Lights YY= No Requirement An "X" located in ANY position in a code string (ESPECIALLY Code 33) indicates the presence of special feature(s). It is important to note that special features may change unit components in unexpected areas so it is recommended to contact Daikin Applied with model and serial number information in order to correctly identify the required part(s). Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 5

Unit Model Number Complete, Continued 20 Auxiliary Controls Digit Y= No Requirement F= Freezestat P= Phase Failure A= Freezestat and Phase Failure Digit 2 Y= No Requirement F= Water Flow Switch Digit 3 Y= No Requirement F= Dirty Filter Switch Digit 4 Y= No Requirement S= S2 Fan Door Cut Out Switch Digit 5 Y= No Requirement F= FS Fan Relay 2 No Requirement, not an SWP Code YY= No Requirement 22 Air Discharge Arrangement YY= No Requirement TY= Top Discharge with No Plenum XX= Special 23 Piping Connection Location (Unit Hand) L= Left Hand R= Right Hand X= Special 24 Condensers S= Cleanable Tube (Low Temp Condensing) G= Cleanable Tube (High Temp Condensing) X= Special 25 2- Way Condenser Water Valve YY= No Requirement = 2-Way Mod. Vlv. (Full flow on shutdown) XX= Special 26 Waterside Economizer Digit Y= No Requirement = Cleanable Coil 2= Non-Cleanable Coil X= Special Digit 2 Y= No Requirement = Std. Valve Control (No Flow on Shutdown) 2= Opt. Valve Control (Full Flow on Shutdown) X= Special 27 Airside Economizer Mixing Box YY= No Requirement XX= Special 28 Heat Selection YYY= No Requirement (Cooling only unit) WY= Row 2 FPI HW Coil less Valve WM= Row 2 FPI HW Coil w/ 2-Way Modulating Control Valve XXX= Special 29 Cabinet Lining Digit L= Solid Liners (2".5# insulation) P= Perf-Liners (2" 3# insulation) X= Special Digit 2 S= Standard Gauge Steel Panels H= Heavy Gauge Steel Panels X= Special 30 Fan Isolation = Seismic Restraints with 2" Deflection Spring X= Special 3 Service Valves and Roto Locks = Dual Filter Drier Service Valves with Compressor Roto-Locks 32 Modular Construction Y= No Requirement X= Special 33 Miscellaneous YY= No Requirement XX= Special 34 Approval Listing Y= No Requirement A= ETL/CETL/ASHRAE 90. X= Special 35 Packaging 2= Shrink Wrap X= Special 36 Parts Warranty A= Standard One Year C= Two Years Total D= Three Years Total E= Four Years Total F= Five Years Total Z= Special 37 Compressor Warranty A= Standard One Year Q= Five Years Total X= Special Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 6

Electrical Legend Designation Description Standard Location 2 ACT3 ACTUATOR MOTOR- ECONOMIZER COMPR./COND. SECTION ACT4 ACTUATOR MOTOR- WATER REGULATING/BYPASS VALVE COMPR./COND. SECTION C- 8 POWER FACTOR CAPACITORS- COMPRESSOR CONDENSER SECTION C0 POWER FACTOR CAPACITORS- SUPPLY FAN SUPPLY FAN SECTION CB0 CIRCUIT BREAKER- SUPPLY FAN MAIN CONTROL BOX DAT SENSOR- DISCHARGE AIR TEMPERATURE DISCHARGE SECTION DHL DUCT HIGH LIMIT MAIN CONTROL BOX DS DISCONNECT- TOTAL UNIT OR COND./HEAT MAIN CONTROL BOX DS2 DISCONNECT- SUPPLY FAN/CONTROLS MAIN CONTROL BOX EXP A, B, C MICROTECH III EXPANSION MODULES MAIN CONTROL BOX EWT SENSOR- ENTERING WATER TEMPERATURE COMPR./COND. SECTION FA, FIB FUSES- CONTROL CIRCUIT TRANSFORMER T, PRIMARY MAIN CONTROL BOX FC FUSE- CONTROL CIRCUIT TRANSFORMER T, SECONDARY MAIN CONTROL BOX F5 FUSE- UV LIGHTS MAIN CONTROL BOX FB3-34 FUSEBLOCKS- ELECTRIC HEAT MAIN CONTROL BOX FP- 8 FROST PROTECTION- REFRIGERATION CIRCUITS CONDENSER SECTION FS, FS2 CONTROLS- FREEZESTAT COIL SECTION GFR, 2 RELAYS- GROUND FAULT MAIN CONTROL BOX GFS, 2 SENSORS- GROUND FAULT MAIN CONTROL BOX GRD GROUND MAIN CONTROL BOX HL3-34 HIGH LIMITS, CONTROL- ELECTRIC HEATERS HEAT SECTION, ELECTRIC HP-8 CONTROLS, HIGH PRESSURE- REFRIGERANT ON COMPRESSORS HS3 SWITCH, HEAT- ELECTRIC HEAT DOOR INTERLOCK HEAT SECTION, ELECTRIC HTR- 8 CRANKCASE HEATERS ON COMPRESSORS LP-8 CONTROLS, LOW PRESSURE- REFRIGERANT ON COMPRESSORS LR0 LINE REACTOR- SUPPLY FAN MAIN CONTROL BOX M- M8 CONTACTORS- COMPRESSORS MAIN CONTROL BOX M9 CONTACTOR- SUPPLY FAN, DUAL CONTACTOR START MAIN CONTROL BOX M0 CONTACTOR- SUPPLY FAN MAIN CONTROL BOX M30B CONTACTOR- REVERSING, BYPASS SUPPLY FAN MAIN CONTROL BOX M30I CONTACTOR- REVERSING, INVERTER SUPPLY FAN MAIN CONTROL BOX M3- M34 CONTACTORS- ELECTRIC HEAT MAIN CONTROL BOX MAT SENSOR- MIXED AIR TEMPERATURE FILTER SECTION MCB MICROTECH III CONTROL BOARD MAIN CONTROL BOX MF, 2 MUFFIN FANS MAIN CONTROL BOX MJ MECHANICAL JUMPER MAIN CONTROL BOX MMP- 8 MANUAL MOTOR PROTECTORS- COMPRESSORS MAIN CONTROL BOX MMP9 MOTOR PROTECTOR- SUPPLY FAN, DUAL CONTACTOR START MAIN CONTROL BOX MMP0 MANUAL MOTOR PROTECTOR- SUPPLY FAN MAIN CONTROL BOX MMP30 MANUAL MOTOR PROTECTOR- INVERTER BYPASS, SUPPLY FAN MAIN CONTROL BOX MP- 8 MOTOR PROTECTORS- COMPRESSORS ON COMPRESSORS OAE SENSOR- OUTSIDE AIR ENTHALPY FIELD INSTALLED OAT SENSOR- OUTSIDE AIR TEMPERATURE FIELD INSTALLED PB POWER BLOCK- TOTAL UNIT OR COMPR./ ELECTRIC HEAT MAIN CONTROL BOX PB2 POWER BLOCK- SUPPLY FAN/CONTROLS MAIN CONTROL BOX PB0 POWER BLOCK- FIELD INSTALLED VFD MAIN CONTROL BOX PC5 CONTROL- PRESSURE, CLOGGED FILTER MAIN CONTROL BOX PC7 CONTROL- PRESSURE/INDUCTIVE RELAY, PROOF OF AIRFLOW MAIN CONTROL BOX PSR, 2 TRANSDUCERS- HEAD PRESSURE CONTROL CONDENSER SECTION PVM, 2 PHASE VOLTAGE MONITORS MAIN CONTROL BOX R3-8 RELAYS- HIGH PRESSURE MAIN/COND. CONTROL BOX R45 RELAY- UV LIGHTS MAIN CONTROL BOX R63 RELAY- DUCT HIGH LIMIT MAIN CONTROL BOX RAT SENSOR- RETURN AIR TEMPERATURE FIELD INSTALLED REC0 RECEPTACLE CABINET SECTIONS RES, 2 RESISTORS- LOW PRESSURE SWITCH MAIN CONTROL BOX RES3 RESISTOR- FREEZESTAT MAIN CONTROL BOX RES4 RESISTOR- ENTHALPY MAIN CONTROL BOX Schematic designators may vary depending on unit size, voltage, and options selected. Refer to the unit schematic for more information. 2 Component locations listed are typical and should be used for reference only. Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 7

Electrical Legend, Continued Designation Description Standard Location 2 S SWITCH- INVERTER/OFF/BYPASS MAIN CONTROL BOX S4 SWITCH- CONTROLS/ON/AUTO MAIN CONTROL BOX S7 SWITCH- INVERTER/OFF/BYPASS MAIN CONTROL BOX S0 SWITCH- CABINET SECTIONS CABINET SECTIONS S2 SWITCH- FAN DOOR INTERLOCK FAN SECTION S40-45 SWITCHES- UV LIGHTS DOOR INTERLOCK CABINET SECTIONS SD SMOKE DETECTOR- SUPPLY FAN DISCHARGE SECTION SHS SENSOR- SPACE HUMIDITY FIELD INSTALLED SPS, 2 SENSORS- STATIC PRESSURE DUCT/BUILDING MAIN CONTROL BOX SV, SV2 SOLENOID VALVES- LIQUID CONDENSER SECTION SV5, SV6 SOLENOID VALVES- HOT GAS BYPASS COIL SECTION T TRANSFORMER- MAIN CONTROL/UV LIGHTS (LINE/5VAC) MAIN CONTROL BOX T2 TRANSFORMER- CONTROL INPUT (5/24VAC) MAIN CONTROL BOX T3 TRANSFORMER- CONTROL OUTPUT (5/24VAC) MAIN CONTROL BOX T4 TRANSFORMER, EXHAUST DAMPER ACTUATOR (5/2VDC) MAIN CONTROL BOX TB TERMINAL BLOCK- INTERNAL MAIN CONTROL BOX TB2 TERMINAL BLOCK- FIELD, CLASS 2 MAIN CONTROL BOX TB3 TERMINAL BLOCK- FACTORY MAIN CONTROL BOX TB4 TERMINAL BLOCK- FIELD (5VAC) MAIN CONTROL BOX UV ULTRA-VIOLET LIGHT(S) COIL/DISCHARGE SECTION VFD0 VARIABLE FREQUENCY DRIVE (VFD)- SUPPLY FAN MAIN CONTROL BOX VM VALVE MOTOR- #- HEATING FIELD PROVIDED/INSTALLED VM5 VALVE MOTOR- #5- COOLING COIL SECTION, COOL WFS SENSOR- WATER FLOW CONDENSER SECTION ZNT SENSOR- ZONE TEMP, SETBACK FIELD INSTALLED Schematic designators may vary depending on unit size, voltage, and options selected. Refer to the unit schematic for more information. 2 Component locations listed are typical and should be used for reference only. Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 8

Unit Layout Diagrams Top View Return Air Opening Condensate Drain Control Panel Access Coil Access Control Panel Final Filters Power Entry Motor/Fan Access Supply Fan Motor Return Plenum/Prefilters Supply Fan Post Filter Rack Waterside Economizer Coil Evaporator Coil Top Supply Air Opening Side View Water Supply Water Return Return Air Opening Supply Fan Compressor/Condenser Compressor/Condenser Access Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 9

Controls Control Box Diagram Diagram is representative of a typical Control Box. Components, component layout, and component quantity may vary depending upon unit size and options selected. Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 0

Controls Control Box Component Label Diagram Note that starting in late 200 all units will have a label similar to the one shown above pasted to the inside of the Control Box door. This label contains schematic designators, part descriptions, and Daikin Applied part numbers. The label shown above is for representative purposes only. Actual part numbers will vary depending upon unit options and features. This RPL is primarily intended for use with General Order (GO) numbers 835060-( ) AND 835067-( ). When selecting parts for units with other GO numbers, confirm the part number(s) required with Daikin Applied before ordering. Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page

Controls Common Control Components Sch. Sym. Description Part Number MCB Main Control Board 9340730 - Battery- MCB 9340900 EXP A, B, C Expansion Modules 9340750 - Connector Set for Extension 2 Spring Cage Top Entry 2 9340930 - Connector, Extension I/O Direct Connect 2 9340970 - Connector, 2-Pin Spring Cage, Top Entry 2 9340302 - Connector, 3-Pin Spring Cage, Top Entry 2 9340303 - Connector, 4-Pin Spring Cage, Top Entry 2 9340304 - Connector, 5-Pin Spring Cage, Top Entry 2 9340305 - Connector, 6-Pin Spring Cage, Top Entry 2 9340306 - Connector, 7-Pin Spring Cage, Top Entry 2 9340307 - Connector, 8-Pin Spring Cage, Top Entry 2 9340308 - Filter Pressure Gauge 0-3 IWC 06007303 FA, B Fuses- T Control Transformer Primary, 6A 30004289 FC Fuse- T Control Transformer Secondary, 2A 0427532 FS, 2 Freezestats 07250200 HP- 8 Switches- High Pressure, Refrigerant 3470 LP- 8 Switches- Low Pressure, Refrigerant 3480 HTR- 8 Crankcase Heater- Compressors 07090280 MP- 8 Compressor Motor Protectors (3HP & 5HP Compressors only) 300045656 SPS, 2 Duct Static Pressure Sensors 7/ & Earlier 9024528 3 Duct Static Pressure Sensors 9/ & Later 907462 4 SPS3 Building Static Pressure Sensor 7/ & Earlier 9024529 3 Building Static Pressure Sensor 9/ & Later 907463 4 PC5 Switch- Dirty Filter, Prefilter 06549380 PC6 Switch- Dirty Filter, Final Filter 06549380 PC7 Relay- Current Sensing 34060 DHL Duct High Limit 06549380 DAT Discharge Air Temperature Sensor 9344602 EFT Entering Fan Air Temperature Sensor 9344602 RAT Return Air Sensor 9344602 OAT Outside Air Temperature Sensor 9344602 MAT Mixed Air Temperature Sensor 9344602 EWT Entering Water Temperature Sensor 9344602 OAE Enthalpy Control, Electro-Mechanical 030706702 Enthalpy Control, Comparative 04926220 RAE Return Air Enthalpy Sensor 04926220 SD Smoke Detector- Supply Air 0988730 SHS Space Humidity Sensor- Wall Mount 06729490 SHS Space Humidity Sensor- Duct Mount 06729500 MF Muffin Fan 7205480 - Fan Guard- Muffin Fan 34370 This Control Board must be programmed in order to function correctly. When ordering a replacement, provide the unit model and serial number so the unit specific software code can be loaded before shipment. 2 These parts are not provided with the Expansion Module. Order separately if needed. 3 The original Transducer is no longer available. This replacement kit requires minor field modifications for proper installation & operation. 4 For units built 8/ contact Daikin Applied to ensure that the correct part(s) are identified. Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 2

Controls Common Control Components, Continued Sch. Sym. Description Part Number R3-8 Relay- High Pressure 349934724 - Relay Base 349934822 R63 Relay- Duct High Limit 349934724 - Relay Base 349934822 R78, 79 Relay- Input to MCB 349934724 - Relay Base 349934822 R83 Relay- Smoke Shutdown 934360 - Relay Base 934370 R86 Relay- Smoke Pressure 934360 - Relay Base 934370 PVM, 2 Phase Voltage Monitor 202200 RES, 4 Resistor,.5K 0446905 RES2, 3 Resistor,.0K 0446900 S Switch- Unit On/Off 00355000 S4 Switch- Inverter Bypass 028798400 S7 Switch- Local On/Off to MCB 80300509 S2 Switch- Fan Door Interlock 033696300 T Transformer- Control, 000VA 038253956 - T Fuse Puller Kit 34995580 - T Finger Safe Cover Kit 34995590 T2 Transformer, 5/24 VAC 75VA 349937303 T3 Transformer, 5/24 VAC 50VA 349937303 WFS Switch- Water Flow (Code 24= ) 9003980 ZNT Zone Temp. Sensor w/tenant Override 3770 ZNT Zone Temp. Sensor w/tenant Override & Remote Set Pt. Adj. 3780 - BACnet MS/TP Communication Module (RS-485) 0900670 - BACnet /IP Communication Module (IP Cable 0 BaseT) 09006709 - LONMARK Space Comfort Controller (SCC) Communication Module 090067 - LONMARK Discharge Air Controller (DAC) Communication Module 0900672 - Remote Keypad Interface 9340800 Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 3

Controls Compressor Contactors and Manual Motor Protectors 2 3F 3B C Compressor HP/460V Ref. Sch. Part Part No. Sym. Description Number 9 0 2 5 M- 8 Contactor, 25A 34993232 Contactor, 32A 349932322 C Contactor Spacer 34990650 2 MMP- 8 Manual Motor Protector 34993405 Manual Motor Protector 349934052 Manual Motor Protector 349934053 3B Link 349932922 3F Auxiliary Contact /NC/NO 34993382 Quantities shown are per compressor. Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 4

Controls Fan Motor Contactor and Motor Protector Configuration Diagrams Fan Contactor Assembly Without Bypass 2 Fan Contactor Assembly With Bypass 2 3B C 3B 4A 4 The above diagrams show typical Fan Control components and component locations. Not all components are used in every assembly. For additional Contactor and Manual Motor Protector configurations, refer to the diagrams on the next page. Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 5

Controls Fan Motor Contactor and Motor Protector Configuration Diagrams, Continued 3E 2 2 3E The above diagrams show typical Fan Control components and component locations. Not all components are used in every assembly. Note that M0 contactors (Ref. #) are shown above. M30 Bypass contactors (Ref. #4) are located in the same position as M0. Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 6

Controls Fan Motor Components 3 HP Motor- Code 7= HS Voltage Ref. Sch. Part Part No. Sym. Description Number 460V M0 Contactor, 9A 3499322 C Contactor Spacer 34990650 2 MMP0 Manual Motor Protector 349934049 3B Link 349932922 4 M30 Bypass Contactor 349934049 5 MMP30 Manual Motor Protector 349934049 CB0 Circuit Breaker 34993962 5 HP Motor- Code 7= JS Voltage Ref. Sch. Part Part No. Sym. Description Number 460V M0 Contactor, 9A 3499322 C Contactor Spacer 34990650 2 MMP0 Manual Motor Protector 349934050 3B Link 349932922 4 M30 Bypass Contactor 3499332 5 MMP30 Manual Motor Protector 349934050 CB0 Circuit Breaker 34993962 7.5 HP Motor- Code 7= KS Voltage Ref. Sch. Part Part No. Sym. Description Number 460V M0 Contactor, 2A 34993222 C Contactor Spacer 34990650 2 MMP0 Manual Motor Protector 34993405 3B Link 349932922 4 M30 Bypass Contactor 34993322 5 MMP30 Manual Motor Protector 34993405 CB0 Circuit Breaker 34993962 One pc. is used for M0 Contactors and two pcs. are used for M30 Contactors. Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 7

Controls Fan Motor Components, Continued 0 HP Motor- Code 7= LS Voltage Ref. Sch. Part Part No. Sym. Description Number 460V M0 Contactor, 8A 34993223 C Contactor Spacer 34990650 2 MMP0 Manual Motor Protector 34993405 3B Link 349932922 4 M30 Bypass Contactor 34993323 5 MMP30 Manual Motor Protector 349934052 CB0 Circuit Breaker 349939622 5 HP Motor- Code 7= MS Voltage Ref. Sch. Part Part No. Sym. Description Number 460V M0 Contactor, 25A 34993232 C Contactor Spacer 34990650 2 MMP0 Manual Motor Protector 349934053 3B Link 349932922 4 M30 Bypass Contactor 34993332 5 MMP30 Manual Motor Protector 349934053 CB0 Circuit Breaker 349939624 20 HP Motor- Code 7= NS Voltage Ref. Sch. Part Part No. Sym. Description Number 460V M0 Contactor, 32A 349932322 C Contactor Spacer 34990650 2 MMP0 Manual Motor Protector 349934054 3B Link 349932922 4 M30 Bypass Contactor 349933322 5 MMP30 Manual Motor Protector 349934055 CB0 Circuit Breaker 349939626 One pc. is used for M0 Contactors and two pcs. are used for M30 Contactors. Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 8

Controls Fan Motor Components, Continued 25 HP Motor- Code 7= PS Voltage Ref. Sch. Part Part No. Sym. Description Number 460V M0 Contactor, 40A 9342682 2 MMP0 Manual Motor Protector 34993446 4 M30 Bypass Contactor 9342692 5 MMP30 Manual Motor Protector 349934055 CB0 Circuit Breaker 349939626 30 HP Motor- Code 7= QS Voltage Ref. Sch. Part Part No. Sym. Description Number 460V M0 Contactor, 40A 9342682 2 MMP0 Manual Motor Protector 34993447 4 M30 Bypass Contactor 9342692 5 MMP30 Manual Motor Protector 34993447 CB0 Circuit Breaker 349939628 40 HP Motor- Code 7= RS Voltage Ref. Sch. Part Part No. Sym. Description Number 460V M0 Contactor, 50A 93426822 2 MMP0 Manual Motor Protector 34993448 4 M30 Bypass Contactor 93426923 5 MMP30 Manual Motor Protector 34993449 CB0 Circuit Breaker 349939629 50 HP Motor- Code 7= SS Voltage Ref. Sch. Part Part No. Sym. Description Number 460V M0 Contactor, 80A 34993262 2 MMP0 Manual Motor Protector 34993449 4 M30 Bypass Contactor 93426923 5 MMP30 Manual Motor Protector 34993449 CB0 Circuit Breaker 34993963 Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 9

Controls Disconnect Switches Sch. Sym. Part Description Switch Toggle DS, 2 Disconnect Switch 00 Amp 34993525 9340660 Disconnect Switch 50 Amp 34993526 9340660 Disconnect Switch 250 Amp 349935226 9340660 Disconnect Switch 400 Amp 349935325 9340660 This list includes the most common Disconnects offered. Due to the various unit options available, before ordering it is necessary to confirm what amperage Disconnect is installed in the unit, or if this is not known, contact Daikin Applied with unit tag number (if available) plus model and serial number information to ensure that the correct Disconnect is identified. Padlock Toggle Disconnect Switch Padlocks NOT included Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 20

Refrigeration & Water Components Refrigeration Circuit Layout Diagram & Components LH Three Compressor Unit shown Thermal Expansion Valve (TEV) Liquid Line Filter Drier Condenser Stack Compressors Description Compr. HP Part Number Qty. Expansion Valve (TEV) 9, 0 3060 Expansion Valve (TEV) 2 3070 Expansion Valve (TEV) 5 36690 Liquid Line Service Valve ALL 0725020 Liquid Line Sight Glass ALL 05997804 Liquid Line Filter Drier ALL 3490 Suction Service Valve ALL 35380 Discharge Service Valve LH Unit (Code 23= L) ALL 07240304 RH Unit (Code 23= R) ALL 07240309 Quantity varies. Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 2

Refrigeration & Water Components Condensers & Condenser Components 7 7 4 3 4 5 2 5 Condensers Compressor HP Description Part Number 2 09 Condenser, Shell & Tube 3500 0 Condenser, Shell & Tube 3500 3 Condenser, Shell & Tube 3504 5 Condenser, Shell & Tube 3504 Condenser Components Ref. Unit Part Quantity Per No. Size Description No. Condenser ALL Pressure Relief Valve 720450 2 ALL Seal, Rotolock 330503005 3 ALL Seal, Rotolock 330503002 4 ALL Head Gasket 905763 2 5 ALL Head Gasket Bolts 90592 6 7 ALL Clamp, Victaulic Fitting (/ & Earlier) 34200 3 2 7 ALL Clamp, Victaulic Fitting (/2 &Later) 908767 3 2 The above diagrams show typical component locations. The number and layout of components will vary depending upon unit size and the number of refrigeration circuits. 2 Because multiple compressor configuration options may be available for a given size unit, before ordering it is necessary to confirm the HP of the compressor the Condenser is serving. If this is not known, contact Daikin Applied with unit tag number (if available) plus model and serial number information to ensure that the correct part(s) are identified. 3 For units built 2/ contact Daikin Applied with model and serial number information so that the correct part can be identified. Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 22

Refrigeration & Water Components Water Valve & Actuator 42 48 47 46 Ref. Unit Part Quantity No. Size Description No. 42 ALL Actuator 34960 2 46 ALL Valve, Water 37330 47 ALL Shaft, Actuator 37320 48 ALL Bearing, Actuator Shaft 9004070 2 Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 23

Compressors Compressor Availability: Code 4= ****** Unit Compressor HP Size 2 3 4 5 6 08 09 09 - - - - 023 0 0 - - - - 023 0 2 - - - - 035 0 2 2 - - - 035 2 2 2 - - - 035, 070 5 5 5 - - - 040 2 2 - - - - 045 2 2 2 2 - - 055 0 0 2 2 - - 055 2 5 5 5 - - 055 5 5 5 5 - - 065, 080 0 0 0 0 2 2 080 0 0 2 2 2 2 080 2 2 2 2 5 5 080, 20 2 2 2 5 5 5 080 2 2 5 5 5 5 05 5 5 5 5 - - 20 5 5 5 5 5 5 These are the most common compressor combinations offered. Due to the various unit configurations available, it is necessary to confirm which compressor is installed in the unit, or if this is not known, contact Daikin Applied with model and serial number information to ensure that the correct compressor(s) are identified. Compressor Part Numbers Cmpr. Voltage Part HP Number 09 460 3090802 0 460 300046086 2 460 30005350 5 460 3000535 Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 24

Fan Motors & Inverters Fan Motors H.P. H.P. Unit ODP Pre. Eff. Code 7= ** Voltage Code 7= *S 03 H* 460/60/3 0658800 05 J* 460/60/3 3020 7.5 K* 460/60/3 30240 0 L* 460/60/3 30260 5 M* 460/60/3 30280 20 N* 460/60/3 30300 25 P* 460/60/3 30320 30 Q* 460/60/3 30340 40 R* 460/60/3 205067200 50 S* 460/60/3 205067600 ABB VFD: Code 2= 3 Motor Horsepower 3 5 7.5 0 5 20 25 30 40 50 Part Number 460V 460V 460V 460V 460V 460V 460V 460V 460V 460V 09948803 09948804 09948805 09948806 09948807 09948808 09948809 0994880 93552309 9355230 Note that the original VFDs are obsolete and no longer available. The above listed VFDs are the recommended replacements. The replacement keypad/display p/n is 300040924. Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 25

Fan Section Fan Assembly Diagrams Side View Fan Wheel Bearing, Drive Side Motor (See Motor Section) Top View Fan Wheel Bearing, Opposite Drive Side Bearing, Drive Side Shaft Motor (See Motor Section) Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 26

Fan Section Wheels & Shafts Fan Wheels Wheel Shaft Part Description Diameter No. 20 Wheel.44 Dia 300046635 27 Wheel.69 Dia 300048286 30 Wheel.69 Dia 300048287 33 Wheel.94 Dia 300048288 36 Wheel 2.9 Dia 300048289 40 Wheel 2.9 Dia 300048290 Fan Shafts Wheel Shaft Part Description Diameter No. 20 Wheel.44 Dia 300046639 27 Wheel.69 Dia 30004829 30 Wheel.69 Dia 300043662 33 Wheel.94 Dia 300048292 36 Wheel 2.9 Dia 300048293 40 Wheel 2.9 Dia 300048294 Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 27

Fan Section Bearings Fan Bearings: Drive Side Wheel Bearing Part Description Description No. 20 Wheel Bearing,.438" 300043663 27 Wheel Bearing,.688" 300043664 30 Wheel Bearing,.688" 300043664 33 Wheel Bearing,.938" 300048295 36 Wheel Bearing, 2.88" 300048296 40 Wheel Bearing, 2.88" 300048297 Fan Bearings: Opposite Drive Side Wheel Bearing Part Description Description No. 20 Wheel Bearing,.438" 300043663 27 Wheel Bearing,.688" 300043664 30 Wheel Bearing,.688" 300043664 33 Wheel Bearing,.938" 300048295 36 Wheel Bearing, 2.88" 300048296 40 Wheel Bearing, 2.88" 300048296 Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 28

Fan Section Fan Drives & Drive Packages Fan Drives Drive components (Fan Sheave, Motor Sheave, V-belt[s], and Sheave Bushing[s]- if required) WITHOUT a specific Drive package specified (Code 8 DOES NOT = 205*, 429*, 446*, 57*, 59*) are NOT listed as they are unique to the unit. If a drive package has NOT been selected, you may use the number from the part and cross reference it in the Daikin Applied Parts catalog, The Daikin Parts E-Commerce site, or contact Daikin Applied with model and serial number information. Drive Packages If a specific Drive Package has been selected (Code 8= 205*, 429*, 446*, 57*, 59*) use the following charts. If it is not known if one of these packages has been selected, contact Daikin Applied with unit tag number (if available) plus model and serial number information to ensure that the correct part(s) are identified. Fan Assy.: 7206470 27" Fan, 57 RPM, 5HP Motor Part Part Qty. Description Number Wheel, 27 300048286 Bearing, Drive Side 300043664 Bearing, Fan Wheel 300043664 Motor, 5HP 30280 Shaft 30004829 Fan Sheave 0484983 Fan Bushing 04846809 Motor Sheave 0484988 Motor Bushing 0484680 V-Belt 049264 2 Fan Assy.: 7206480 27" Fan, 429 RPM, 5HP Motor Part Part Qty. Description Number Wheel, 27 300048286 Bearing, Drive Side 300043664 Bearing, Fan Wheel 300043664 Motor, 5HP 30280 Shaft 30004829 Fan Sheave 048498 Fan Bushing 04846809 Motor Sheave 0484988 Motor Bushing 0484680 V-Belt 049264 2 Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 29

Fan Section Drive Packages, Continued Fan Assy.: 7206460 30" Fan, 59 RPM, 25HP Motor Part Part Qty. Description Number Wheel, 30 300048287 Bearing, Drive Side 300043664 Bearing, Fan Wheel 300043664 Motor, 25HP 30320 Shaft 300043662 Fan Sheave 049026620 Fan Bushing 0484690 Motor Sheave 04902667 Motor Bushing 03040800 V-Belt 029652600 3 Fan Assy.: 7206450 33" Fan, 446 RPM, 30HP Motor Part Part Qty. Description Number Wheel, 33 300048288 Bearing, Drive Side 300048295 Bearing, Fan Wheel 300048295 Motor, 30HP 30340 Shaft 300048292 Fan Sheave 04849826 Fan Bushing 0484692 Motor Sheave 04849824 Motor Bushing 048469 V-Belt 000890800 2 Fan Assy.: 7206590 40" Fan, 205 RPM, 50HP Motor Part Part Qty. Description Number Wheel, 40 300048290 Bearing, Drive Side 300048297 Bearing, Fan Wheel 300048296 Motor, 50HP 205067600 Shaft 300048294 Fan Sheave 049026630 Fan Bushing 0484724 Motor Sheave 049026626 Motor Bushing 030400900 V-Belt 02929500 3 Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 30

Fan Section Seismic Spring Vibration Isolators Vibration Isolators- Seismic Spring Fan Sizes Part Spring(s) Part Quantity Used with Description Color 2 No. 3-36.5" Seismic mount, 33 lb. Yellow 2060280 3-36.5" Seismic mount, 43 lb. Purple 20602802 3-36.5" Seismic mount, 59 lb. Black w/ Silver Markings 20602803 3-36.5" Seismic mount, 83 lb. Red w/ White Markings 20602804 3-36.5" Seismic mount, 20 lb. Green 20602805 3-36.5" Seismic mount, 55 lb. Black w/ Yellow Markings 20602806 3-36.5" Seismic mount, 95 lb. Gray 20602807 3-36.5" Seismic mount, 236 lb. Gray & Green w/ White Markings 20602808 3-36.5" Seismic mount, 300 lb. Gray w/ White Markings & Black 20602809 3-36.5" Seismic mount, 390 lb. 2 Gray 20602260 3-36.5" Seismic mount, 472 lb. 2 Gray w/ White Markings 206022602 3-36.5" Seismic mount, 600 lb. 2 Gray w/ White Markings & Black 206022603 40, 44 Seismic mount, 2 lb. Brown 2060290 40, 44 Seismic mount, 7 lb. White w/ Yellow Markings 20602902 40, 44 Seismic mount, 24 lb. Red 20602903 40, 44 Seismic mount, 348 lb. Green w/ Yellow Markings 20602904 40, 44 Seismic mount, 453 lb. Blue 20602905 40, 44 Seismic mount, 590 lb. White w/ Sliver Markings 20602906 40, 44 Seismic mount, 676 lb. Green & White 20602907 40, 44 Seismic mount, 767 lb. White w/ Sliver Markings & Silver 20602270 Quantity and location of each isolator used depends upon the motor and drive package selected. Visually confirm the color and location where the required isolator is used in the assembly before ordering, or contact Daikin Applied with model and serial number information so that the correct isolator(s) can be identified. 2 Spring colors may vary dictated by vendor updates. Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 3

Hot Water Heating Coils, Waterside Economizer Coils, & Evaporator Coils Hot Water Heating Coils Hot Water Heating Coils are serial number specific. Contact Daikin Applied with Unit GO & Item number and Unit Serial Number in order to identify the required coil. Waterside Economizer Coils Economizer Coils are serial number specific. Contact Daikin Applied with Unit GO & Item number and Unit Serial Number in order to identify the required coil. Evaporator Cooling Coils Evaporator Cooling Coils are serial number specific. Contact Daikin Applied with Unit GO & Item number and Unit Serial Number in order to identify the required coil. Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 32

Cabinet Door Components 4 3 2 Cabinet Door Components Ref. Part Part No. Description No. Handle, Standard 3630 2 Handle, Lockable 35250 3 Hinge 346502 4 Pawl 36440 Handle nuts, bushings, washers, roller cams, etc. are furnished with the handles and are not available separately. 6 7 7 Control Box Door Components 5 9 8 Ref. Part Part No. Description No. 5 Handle 308780 6 Panel Latch Assy. 34080 7 Hinge 346502 8 Filter Kit 34360 9 Louver 34270 Self-Contained; SWP 08-20 Vintage G Rev. C 09/8 RPL 700092 / Page 33