RF Programmable Room Thermostat Installation Instructions

Similar documents
Programmable Room Thermostat Installation Instructions

ESRTP4RF. RF Programmable Room Thermostat with TPI, Optimum Stop, Delayed & Optimum Start. User and Installation Instructions

ESRTPRF. Wireless Programmable Room Thermostat, with Delayed & Optimum Start. User and Installation Instructions M/A MANUAL

Electronic Dual Cylinder Thermostat Installation Instructions

ESRTD3. Digital Room Thermostat with TPI & Delayed Start. User and Installation Instructions

ESRTD2 Electronic Room Thermostat, with LCD Display

RF Programmable Room Thermostat User Instructions

CentaurPlus ZW and HRT4-ZW

Digital Room Thermostat with TPI & Delayed Start User Instructions

Electronic Thermostat With RF

ES3247B. 3 Channel Programmer. User and Installation Instructions

ESi CONTROLS BROCHURE LANDSCAPE V5.indd 1 14/08/ :31

ESCTDEB. Electronic Dual Cylinder Thermostat* User and Installation Instructions. Patent pending

Digital Electronic Thermostat With RF

Digital Electronic Thermostat With RF

3 Channel Multi-Purpose Programmer User Instructions

Digital Room Thermostat

Digital Thermostat. Models: VS35W and VS35B INSTALLER / USER MANUAL

Easy-Stat. Wireless Programmable Room Thermostat Pt No

Digital Thermostat Models: VS30W and VS30B

RT021 User and Installation Instructions

Electronic Dual Cylinder Thermostat User Instructions

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

SMARTELEC 2 ENERGY SAVING CONTROL INSTALLATION AND OPERATING MANUAL

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

4 in 1 Digital Thermostat Control

Model: RT310i. Smartphone Controlled Thermostat. Installation Manual

PROGRAMMABLE 7-DAY RF THERMOSTAT

RET2000 MD Electronic digital thermostat with LCD, delayed start. Danfoss Heating. Installation Guide

Operating Instructions Model: PRT-RP Version 3. 05/11 Revision 2 Ref: PRTRP

CS-11 LCD Timeswitch: Central Time Control of Multiple Thermostats

MAKING MODERN LIVING POSSIBLE. Danfoss Heating. RET2000 B/M/MS Electronic digital thermostat with LCD Installation Guide

Contents. Box contents: JGSTAT2B (Black) Fixing screws (White) Icons used in this manual:

Model: RT510RF. Installation Manual

Model: RT310. Installation Manual

Model: Touch-RS. 1 Touch-RS

DT92 WIRELESS DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

: PRT / PRT PRT / PRT-N1

- Schedule with up to 3 ON periods per day to suit the comfort needs. - Hot water Boost function for temporary override

Room thermostat with 24-hour time switch and large LCD

C-Stat 17-ZW User Instructions

Model: Available in : Sapphire Black and Glacier White. 1 Series

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

SMART THERMOSTAT WITH HOT WATER CONTROL

Table of Contents. Model: Series. Available in : Sapphire Black and Glacier White. Product Image. 20 Table of Contents.

Operating Guide: for the Warmup tempo Digital Programmable Thermostat Part of the Element Series Introduction

Table of Contents. Product Image 1 Locking/Unlocking the neoair 24 Table of Contents 2 Frost Protection 25 What is a Programmable Room Thermostat?

USER GUIDE Wireless room thermostat with hot water control (DHW & single zone CH)

CS027 User Instructions

Model: Available in: Sapphire Black and Glacier White. 1 Series

Heating is great when you control it. USER MANUAL. Wireless Programmable Room Thermostat. Model No.: LS Scan for App

Operating Instructions Model: PRT-TS WiFi RF. 01/13 Version 1 Ref: PRT-TSWIFI RF

Model: RT310RF. Installation Manual

User start guide Connected wireless room thermostat Logic Combi C / Vogue Gen 2 Combi Logic Max Combi C / Vogue Max Combi Vogue Combi C / Logic Combi

PROGRAMMABLE 7-DAY THERMOSTAT

Model: PRT-TS / PRT-NTS

PRT-TS WiFi PRT-TS WiFi

L. Terminal block Connecting Label:

Satchwell. DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL FEATURES

Honeywell Homes T3, T3M & T3R

Room Sensor [RBT-3C] Installation Instructions

Model: PRT2-TS / PRT2-NTS EU. Model: Touch Duo

Electronic 7 Installation Instructions

Instruction FH-CWP Thermostat

Operating Instructions

DT90 DIGITAL ROOM THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Phone: * Website: wiser.draytoncontrols.co.uk /DraytonHome

Thermostat install guide

Programmable Thermostat with Plug in RF Boiler Control Model: ST620VBC INSTRUCTION MANUAL

isense & isense-ht 230V Flush Mounted Domestic Continuous Extract Fans

Heating Controls Technical

INSTALLATION INSTRUCTIONS

Model: Edge-HC. 1 edge-hc

ST325. Thermostat. The ST325TX can be used with any of these receivers RXBC605 RXST625 RXRT505 RXVBC605 RXWBC MHz

VITMR-EBDSPIR-PRM. PIR Presence/Absence Detector IR with Ceiling Rose. Product Guide. Overview. Features

Digital Control Unit- Installation, Operation & Maintenance IMPORTANT INFORMATION

LYRIC T4, T4R& T4M PRODUCT SPECIFICATION SHEET FEATURES

SCS311 / SCS317 Installation Instructions

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

Hive Active Heating. Thermostat installation guide

Model: Slimline-RF. 1 Slimline Series

Operating Instructions Model : HC HC-N

Electronic timeswitch

Instruction Manual WARNINGS

CM921 - User Guide 1 day Wireless Programmable Room Thermostat with LoT technology

Model: Touch-RF. 1 Wireless Series

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

Battery Powered Electronic Programmable Room Thermostat

RDJ10. Room temperature controller with 24-hour time switch and large LCD. For heating systems

EBDSPIR-PRM-VFC & EBDSPIR-PRM-VFC-NC

MICROtrac MICROPROCESSOR BASED WATER TREATMENT CONTROLLER. Installation and Operation Manual REV. L

SRT321 User and Installation Instructions

ECO AND DATE /06 ARTWORK DESCRIPTION. 22 page A6 : Saddle stitch (2-wire) 6 page : 4 colour : 170gsm Silk 18 page : 1 colour : 100gsm Silk

CM907- TRV PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

FAITH (dmev) 230V / 24V DC SELV Flush Mounted Domestic Continuous Extract Fans

Model: Slimline-B. Battery Series

CM901 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Integrated PIR detectors

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Transcription:

ESRTP4RF RF Programmable Room Thermostat Installation Instructions

Thank you for choosing ESi Controls. All our products are tested in the UK so we are confident this product will reach you in perfect condition and give you many years of service. However, for additional peace of mind, we recommend you register your product online at www.esicontrols.co.uk/warranty for your extended warranty. 2

Contents Installation Instructions 1 Technical Specification 1.1 Programmable room thermostat 6 Receiver 6 2 Installation Instructions 2.1 Installation 7 2.2 General Safety 7 2.3 Maintenance 8 2.4 Safety Notice 8 2.5 Fitting the Programmable Room Thermostat 8 2.6 Fitting the Receiver 9 2.7 Commissioning/Configuring 10 2.8 Wiring Diagram (Receiver) 11 3 Technical Settings 3.1 Setting TPI, Delayed & Optimum Start 12 3.2 Setting Sensitivity/Swing and Calibration 13 3.3 Setting the Landlord Service & Time Events 13 3.4 Lockout feature 15 3.5 Setting the Installer Lockout feature 15 3

4

Installation Instructions 5

1. Technical Specification Programmable Room Thermostat Programming 7 Day, 5/2 Day & 24Hr Power Supply 2 x 1.5V Lithium Batteries (type: AA size) Temperature Sensor Type +/- 1 C at 20 C Temperature Adjustment Range 5 C to 35 C Plastic Thermoplastic, flame retardant Number of programs 4 or 6 (Default: 4) Protection Rating IP30 Dimensions 127mm(L) x 81mm(W) x 28mm(D) BST/GMT Time Change Automatic Factory Pre-Set Programme Yes EN60730-1 EN 60730-2.7, EMC Complies with: Directive 2014/30/EU, LVD Directive 2014/35/EU Fixing Power Supply Voltage Power Consumption Contact Type Plastic Transmission Distance Protection Rating Dimensions Complies with: Receiver Easy Fit Back Plate 230VAC, 50Hz 6W 6 (2)A. 230VAC SPDT (Volt Free changeover contacts) Thermoplastic, flame retardant Approx. 30m in open terrain IP30 135mm(L) x 90mm(W) x 33mm(D) EN60730-1 EN 60730-2.7, EMC Directive 2014/30/EU, LVD Directive 2014/35/EU, R&TTE Directive 1999/05/EC. 6

2. Installation 2.1 Installation Safety Instructions The unit must be installed by a suitably qualified person in accordance with the latest IEE Wiring Regulations. Isolate mains supply before commencing installation. Please read all instructions before proceeding. Ensure that the fixed wiring connections to the mains supply is via a fuse rated at not more than 6 amps and class A switch having a contact separation of a minimum of 3mm in all poles. The recommended cable sizes are 1.0mm sqr or 1.5mm sqr. No earth connection is required as the product is double insulated but ensure continuity of earth throughout the system. 2.2 General Safety Instructions When fitting batteries, do not mix old and new batteries together. Do not use rechargeable batteries. This product complies with the essential requirements of the following EC Directives: Electro-Magnetic Compatibility Directive 2014/30/EU Low Voltage Directive 2014/35/EU EC Marking Directive 93/68/EEC R&TTE Directive 1999/05/EC 7

2.3 Maintenance Always isolate the mains supply before commencing any work, servicing or maintenance on the system. And please read all instructions before proceeding. Arrange for an annual maintenance and inspection schedule to be carried out by a qualified person on every part of the heating and hot water system. 2.4 Warning Notices WARNING: Always isolate the AC mains supply before installing. This product must be fitted by a competent person, and installation must comply with the guidance provided in the current editions of BS767 (IEE wiring regulations) and part P of the building regulations. WARNING: Do not fit the receiver to a back plate that is live. Switch off mains before fitting back plate as live and neutral contacts may touch while mounting receiver on plate and damage the product. 1.5m 2.5 Fitting the Programmable Room Thermostat The ideal position to locate the Programmable Room Thermostat is about 1.5m above floor level, in a location where the thermostat is accessible, reasonably lit and free from extremes of temperature and draughts. Do not position the thermostat near sources of heat, such as radiators, lights, TV, direct sunlight or on an outside wall 8

Installation 1. Remove the front cover using a flat screwdriver in the two holes at the top of the programmer and separate from back plate. 2. If required, fix the back plate directly on the wall using suitable wall plugs and screws or mount over existing wall box. Replace the thermostat onto the back plate, securing the bottom of the thermostat first and clicking the thermostat into place. Alternatively, use the stand provided. 3. Insert the 2 x AA batteries provided in the battery compartment on the front of the thermostat, underneath the facia. The Programmable Room Thermostat is now installed and will automatically start to control the room temperature according to the factory pre-set programme as shown in the User Instructions. The display shows the correct time and date which is automatically set together with the actual room temperature. 2.6 Fitting the Receiver Installation 1. Loosen the screws on the back-plate and remove from the Unit. 2. Fix the back-plate, terminals at the top, either direct onto a flat wall using wall plugs and screws or on a flush mounting single conduit box. Route the wires through the back of the wall plate and fit the wires to the wallplate in accordance with the relevant diagram and in accordance with I.E.E. regulations. 3. Fit the Unit onto back-plate and tighten the screws. 4. Ensure an appropriate fuse is fitted to the circuit before reconnecting to the mains supply. 9

2.7 Commissioning/Configuring 1. If the receiver and thermostat have been supplied as a kit, the units have already been paired in the factory and no pairing is needed. 2. Power up the receiver and press M/A (Manual/Auto) button 1 for approximately 10 seconds until the MANUAL (green) light 2 begins to flash. 3. On the thermostat, switch the slider to OFF. Press and hold the A, H and + buttons for 3 seconds until the symbol flashes. 4. When the light on the receiver stops flashing the two units are paired. 5. If unsuccessful, repeat steps 2-3. If still unable to pair, leave the unit powered on for 5 minutes and repeat the steps above. 6. The programmer display will show symbol when it is able to receive signal and symbol when it is unable to receive signal. M/A MANUAL 1 2 10

2.8 Wiring diagram Programmable Room Thermostat Receiver Wiring for combi boiler RECEIVER BACKPLATE N L 1 2 3 L N N L T1 T2 BOILER Wiring for basic 230V boiler RECEIVER BACKPLATE N L 1 2 3 L N N.B. DO NOT use a link wire on volt free or low voltage boilers Terminal 2 is SL For information on wiring to Terminal Identifier Description N Neutral Neutral L Live Live Feed (230V AC) 1 COM Linked Live Feed (230V AC Heating Applications Only) 2 N/O Normally open 3 N/C Normally closed (NC) N L BOILER For information on wiring to the boiler please contact your boiler manufacturer directly! 11

3. Technical settings 3.1 Setting TPI, Delayed or Optimum Start 1. Switch the slider to OFF. Press and keep holding the A and H buttons together (under the fascia), then press the Next button to enter the technical settings. Release all buttons. 2. Press the +/ buttons to choose between:- OFF: The programme will run according to settings DS (dl StAr DS): When ON, the programmer will run in Delayed Start mode. The start of the next programme may be delayed up to 45 minutes depending on the room temperature S (OP StAr OS): When ON, the programmer will run in Optimum Start mode 3. Press the Next button and press the +/ buttons to turn OP STOP (Optimum Stop) ON/OFF. 4. Press the Next button to enter the TPI settings. Press +/ to choose between:- OFF: Working under normal swing value 3 Cycles: ON/OFF one cycle is 20 minutes. This is recommended for oil boilers 6 Cycles: ON/OFF one cycle is 10 minutes. This is recommended for gas boilers (default setting) 5. Press the Next button to continue to the Sensitivity/ Swing and Calibration settings below. 12

3.2 Setting Sensitivity/Swing and Calibration 1. Switch the slider to OFF. Press and keep holding the A and H buttons together (under the fascia), now press the Next button and the technical settings menu will be displayed. Release all buttons. 2. Press the Next button until you get to the SWING settings (5U1n9 is displayed at the bottom of the LCD next to a flashing 0.5). Press +/ to choose between 0.5 to 2.0 3. Press the Next button to enter the ADJ settings. Press +/ to choose between -3 to 3 (this calibrates the temperature). 3.3 Setting the Landlord Service & Time Events 1. Switch the slider to OFF. Press and keep holding the A and H buttons together (under the fascia), now press the Next button and the technical settings menu will be displayed. Release all buttons. 2. Press the Next button until you get to SER (service interval) Settings. A numeric password will be required to enter this section. The factory default password is 0000. N.B. The screen will display Err if the incorrect password is entered. 3. Press +/ to enter the first digit of the password. Press the H button to move to the next digit. Repeat this until all 4 digits have been entered. 4. Press the Next button to enter the service interval settings. 5. Use the +/ buttons to choose between:- 13

OFF: Turns the service interval off 1: Reminds the user when the annual service is due by displaying SER in the screen 30 days before due date 2: Reminds the user when the annual service is due by displaying SER in the screen 30 days before due date and only allows the system to run for 45 minutes per hour after the due date has passed 3: Reminds the user when the annual service is due by displaying SER in the screen 30 days before due date and only allows the system to run for 30 minutes per hour after the due date has passed 4: Reminds the user when the annual service is due by displaying SER in the screen 30 days before due date and only allows the system to run for 15 minutes per hour after the due date has passed 6. Press the Next button. Use +/ to set the due date (from 28-366 days). 7. The left of the LCD screen will display the recorded running time. Holding the C button for 2 seconds will zero to the time. 8. To change the code, go to the Due Date setting (in SER settings), press the A button for 2 seconds. NEU CODE will appear at the bottom of the LCD display. Press +/ to set the first digit, then press the H button. Repeat this for all four digits. Press the A button for 2 seconds again to set the new code. The screen will display SET to confirm the change. 9. The system will start timing after the thermostat is powered on (Running Time). When the running time reaches 30 days from the Due Date, the screen will display SER. When the running time is more than or 14

equal to the Due Date, the screen will display SER constantly and the system ON time will be controlled by the SER SET. N.B. When the system is running to the ON condition, but is limited by the SER SET (and therefore cannot be ON), the screen will flash the ON symbol. 10. Press Next to enter the PROGRAMMES setting, press +/ to choose either 4 or 6 time temperature events per day. 11. To exit the installer setting press the Home button. 3.4 Lockout Feature: The RTP4 and RTP4RF comes with a lockout feature which enables the installer to disable certain functions of the thermostat to a complete lockdown depending on the mode selected. 3.5 Setting the Installer lockout mode 1. Follow steps 1 to 4 above 2. Press the Next button to enter the installer lock settings. 3. Use the +/ buttons to choose between: - Default Setting 1 This mode works as a standard Programmable Room Thermostat. Partial Lockout 2 This mode allows the installer to set the Maximum temperature Setpoint (factory default 21 c), and allows the end user to adjust all other settings apart from maximum temperature set point. 15

Partial Lockout 3 This mode allows the installer to set the Maximum temperature Setpoint (factory default 21 c), and locks all keys/slider except, to change the time and date, off (frost protection) and allow temporary manual override (temperature Up/Down arrows). Partial Lockout 4 This mode allows the installer to set the Maximum temperature Setpoint (factory default 21 c), and locks all keys/slider except from off (frost protection) and allow temporary manual override (temperature Up/ Down arrows). Full Lockout 5 This mode locks all keys/slider. The End user cannot adjust anything. 4. To exit the Installer Menu, press the Home Button. Number Time / Date Program Permanent Manual Override Temp Manual Override All Day N.B. *Temperature can be adjusted up to the installer set limits. Holiday 1 2 * * * * 3 * 4 * 5 16

17

WARNING: Interference with sealed parts renders the guarantee void. In the interests of continuous product improvement we reserve the right to alter designs, specifications and materials without prior notice and cannot accept liability for errors. 18

We are continuously developing our products to bring you the very latest in energy saving technology and simplicity. However, should you have any questions setting up your controls please email us at sales@esicontrols.co.uk. 19