Description. Applications

Similar documents
Description. Applications

Comfort. Description. Applications

Description. Construction

HLA Series Hazardous Location Fan Forced Unit Heater

KUH. Horizontal Unit Heater. Applications. Description

HLA Series Hazardous Location Fan Forced Unit Heater

Circulation Heaters Selection Guidelines

Circulation Heaters Selection Guidelines

EXH Series Explosionproof Electric Air Heaters

Differences Among Screw Plug Immersion Heaters

Brasch Hazardous Location Unit Heaters

FX5 Series Explosion-Proof Electric Air Heaters

Convection Heaters. Type XB. Product Description. Selection of Temperature Code. Construction and Installation. Special Wattage and Lengths

Industrial Air Heaters

ULTRA-SAFE EXP. Applications E X P L O S I O N - P R O O F H E A T E R S

LUH HORIZONTAL FAN-FORCED UNIT HEATER

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Thermal Devices Inc. Mount Airy, Maryland USA Process Air and Radiant. ADH Typical Installation.

Type UB-2502A and UB-3002A Forced-Air Heater

FE1 Explosion-Proof Electric Air Heaters

Ultra-Safe EXP Unit Heater

Explosion-Proof Forced Air Unit Heater - XGB

Thermal Devices, Inc. Mount Airy, Maryland USA

XB Convection Heater. Convection Heaters. Applications. Special Wattage and Lengths. Selection of Temperature Code. Construction and Installation

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

Explosion-Proof Forced Air Unit Heater - XGB

XGB Unit Heater. Certification. Model Coding XGB 038 T3B 3 1 T TEMPERATURE CODE T3B (165 C) T3A (180 C) T2D (215 C) T2C (230 C)

CF1 ProVector Explosion-Proof Heaters

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

Pipe Thread Heaters. Construction Features. 1" 2-1/2" Pipe Thread Heaters

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

Chromalox. Installation, Operation. Circulation Heaters for Oil or Water Heating RENEWAL PARTS IDENTIFICATION PE GENERAL NWH

CX1 ProVector Explosion-Proof Heaters

XEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

Installation and Operation Instructions. Versa. Screw Plug Oil & Water Immersion Heater. PD January 2018

How 1 is your resistance. wire sized? What grade of magnesium oxide is being used? How 3 is your cold pin attached to your resistance wire?

AEU1. Explosion-Proof Electric Air Heater For Hazardous Locations

*RENTAL* Class 1 Division Watt Incandescent Light - Explosion Proof - Wall Mount Volts

Electric Unit Heaters for Standard and Hazardous (Classified) Locations

Technical Specification VFD

Installation Instructions U-RAD-LT Electric Radiant Heaters

Tubular Industrial Process

Pipe Thread Heaters. Construction Features. Star Electric to Order Call " 2-1/2" Pipe Thread Heaters

HD3D Forced-Air Heater

HLA Series Hazardous Location Fan Forced Unit Heater Data Sheet

COLD WEATHER SOLUTIONS: ELECTRIC HEAT AND CONTROL PRODUCTS

25W Hazardous Location Integrated LED Light Fixture Lumens - Low Profile - ATEX IEC CSA UL

ChromaStar. Comfort. Infra-Red Radiant Heaters. Description. Portable. Applications. Fixed Overhead. 1.5 to 13.5 kw. 5,118 to 46,062 BTU/Hr

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Performance Data. Accessories Enclosure Heaters. curus Component Recognized; File No. E IP 20 CE

UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

Applications. Standard Materials

Custom Duct Heaters. Special Applications

LTFX Electric Tank Immersion Heaters Installation Instructions

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Powers Controls ET 134 Low Temperature Detection Thermostat

ULTRA-SAFE Explosion-proof Duct Heaters

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

EVLPF Series Compact Fluorescent

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR PIPE THREAD IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Installation, Operation and

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

CXH-A Forced-Air Heater

ULTRA-SAFE Explosion-proof Duct Heaters

Installation Instructions Type XPMC Air Heater for Hazardous Locations

Standard Duct Heaters Open Coil

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

4' 2 Lamp Fluorescent Light Fixture - Emergency Battery Backup - T8 Bulbs - Multi-voltage - CID2

Custom Duct Heaters. Special Applications

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

RENEWAL PARTS IDENTIFICATION. Type TTUH and TTUH-CO URN Heaters. Dimensions (In.) Extends. Model Volts kw W/In 2 A B C D

PANELBOARD PROTECTION ON A GLOBAL SCALE

PILOT VALVE ENCLOSURES FOR HAZARDOUS LOCATIONS PENTAIR CLEAN AIR SYSTEMS

Explosion-proof Duct Heaters

Explosion-Proof and Fan-Forced Unit Heaters. Our products do more in a wide range of applications. Expect More.

Dräger Polytron 5700 IR Detection of flammable gases and vapours

VA G 052 S

Powers Controls Low Temperature Detection Thermostat

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Types SDRA and SDRA-RG RENEWAL PARTS IDENTIFICATION

48W Fluorescent T8 Light w/ Emergency Backup Dimmable Ballast - (2) 2 Foot T8 Lamps - C1D2

3-6VFD Series Combination Flame and Explosion Proof Pilot Valve Enclosure

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Overview of Hazardous Locations as They Relate to Solenoid Valves

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

Performance Data. curus Component Recognized; File No. E IP 20

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

INSTRUCTION MANUAL. E2xB05 & E2xB10 Xenon Beacons For use in Hazardous Locations

Immersion Heaters. Screw Plug Immersion Heater

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

Screw Plug Immersion Heaters

Hazardous Area LED Light -Class 1 Div 2 Groups A, B, C, D and Class 2 Div 2 F,G - 4' 4 lamp

208W Explosion Proof Low Profile LED - Emergency Backup - 27,040 Lumens - C1&2 D1&2 - ATEX /IEC

VIII. Heaters Mobile Climate Control 121 MCC Reference Manual 2014

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Transcription:

CVEP PDS CVEP Convection for Hazardous Heater For Locations Hazardous Locations Convection Heater 1.8 to 9.0kW (T-2A) 280 C (536 F) 1.6 to 4.0kW (T-3A) 180 C (356 F) 1.8 to 9.0kW (T-2) 1.8 300 C to 9.0kW (572 F) (T-2A) Europe 280 o C (536 o F) 1.6 to 4.0kW (T-3) Europe 200 C (392 F) 1.6 to 4.0kW (T-3A) 180 120V o C (356 to 575V o F) (1 or 3 Phase) 120V to 575V (1 or 3 phase) Prewired Control Options Prewired UL and Control CSA Listed Options for Class I or II, Groups B, C Many & D Division Models Available 1 & 2 Environments From Stock Description The Chromalox CVEP convection heater is designed and manufactured to provide a rugged, corrosion-resistant heat source for areas where volatile flammable liquids, gases or vapors are present. North American Models All basic models without controls are UL listed and CSA certified for use in areas designated as Class 1, Division 1 or 2 Group B, C or D locations. The CVEP is available in ratings where the maximum allowable heater temperature is 180 C (365 F) NEC identification T3A; or 280 C (536 F) NEC identification T2A. Features Prewired Control Options - Integral thermostat, contactor and transformer eliminate the need to purchase and wire separate controls, simplifying installation and reducing costs. (North American approvals only) Heavy Duty, Corrosion Resistant Housing constructed of polyester powder coated 16 Gauge Steel. High Quality, Long Life Heating Element - Sealed, heavy duty, low wattdensity high grade resistance wire in MgO core. Element is inserted in copper and aluminum fin tube assembly, designed for low temperatures and long life. UL and CSA Listed for Class I, Group B, C & D Division 1 & 2 Environments European Models Meet ATEX Directive 94/9/EC 0359 II 2 G EEx d IIB T3/T2 ITS04ATEX11896 European Models European model ratings are for use where the maximum allowable heater temperature is 300 C (572 F) T-2 at 1.8kW, 3.6kW, 4.5kW, 7.6kW, 9.0kW or 200 C (392 F) T-3 at 1.6kW, 3.2kW and 4.0kW. Applications Petroleum Refineries, Gasoline Storage and Dispensing Areas Industrial Areas Using Flammable Liquids in Dip Tanks Petrochemical Manufacturers Dry Cleaning Plants Utility and Natural Gas Plants Aircraft Hangers/Fueling Areas Solvent Extraction Plants Storage Areas for Flammable Products or Batteries Sewage Treatment Plants Hydrogen Atmospheres Explosion-Proof Junction Boxes included for conduit entry and ease of power wiring. Sloped Top Cabinet Ensures Maximum Ventilation by preventing objects from being set on top which could restrict airflow. Easily Mounted with integral mounting brackets provided for wall installation. PH: 1-800-443-2640 FX: 412-967-5148 www.chromalox.com 2004 Chromalox, Inc.

CVEP - Convection Heater For Hazardous Locations Models With Built-In Controls (North American Models Only) Specifications Chromalox CVEP heaters are available for immediate shipment from stock with built-in controls to reduce field installation costs. The control options include a built-in thermostat, contactor and/or control voltage transformer. Control voltages of 24V, 120V, 208V, 240V or 277V are available. Thermostat, contactor and control options are given on page 6. The following listing represents CVEP heaters with controls that are available from stock. Stocked Models Weight Dimensions kw Volts Phase Model No. Status PCN (Lbs.) (In.) 3.6 208 1 CVEP-36-81-00-42 S 028644 60 Fig. 1 3.6 240 1 CVEP-36-21-00-42 S 028660 60 Fig. 1 3.6 480 1 CVEP-36-41-32-42 S 028652 70 Fig. 3 Remote Temperature Control WR-80EP Explosion-Proof Thermostat Remote Mounting TAM-EX Explosion-Proof Ambient Thermostat Remote Mounting Comfort/space heating applications UL/CSA listed (Class I, Group D; Class II Groups E, F & G) Calibrated dial and adjustment knob to simplify setting Hydraulic action thermal element unaffected by vibration, no levelingrequired 1/2 female pipe wiring connection Temp. Range Maximum Rating (amps/watts) ( F) 120Vac 240Vac 277Vac 480Vac 40-90 25/3000 22/5280 18/5000 125V/A* Model No. Status PCN Wt (kg) WR-80EP S 266124 5lbs (2-3) * Pilot duty (use with a-c contactor) Remote wall thermostat for use in Europe Thermostat for controlling ambient temperature with sensing bulb mounted on the side of enclosure IP54 aluminum enclosure with integral d type microswitch (certification EExdIIC) Temperature adlustment possible without isolating power or removing cover through cover mounted window Supplied with 3m of cable, protected by flexible, stainless steel sleeve permanently connected to microswitch Ts Ts Tm Tm Wt. Ref. Range Diff. Mini. Max. Mini. Max Contact (kg) TAM050 EX +50 C 2 C -70 +70-20 40 5A/250Vac 0 (4) WARNING: Hazard of fire. These two controls function as temperature controls. Because they do not fail safe, an approved temperature and/or pressure safety control must be used for safe operation. 2

Convection Heater For Hazardous Locations - CVEP Dimensions In. (cm) A 9 B 3-1/4 (8.2) C 5-1/8 (13) Dimensions In. (cm) kw A B C 1.6, 1.8 and 3.6 34 (86.4) 20-1/16 (51) 8-15/16 (22.7) 3.2 and 7.6 58 (147.3) 20-1/16 (51) 8-15/16 (22.7) 4.0, 4.5 and 9.0 70 (177.8) 20-1/16 (51) 8-15/16 (22.7) Dimensions In. (cm) Power & Temperature Control Options Power Control Thermostat Figure Combination Option Number 00 00 1 00* 40 5 00* 42 2 30-35* 00 4 30-35* 40 4 30-35* 42 3 *North American Models Only Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 1" NPT 1" NPT 1" NPT 3/4" NPT 3/4" NPT 7 (17.8) 7-5/8 (19.4) 8-7/8 (21.9) 8-7/8 (21.9) 8-7/8 (21.9) 3

CVEP - Convection Heater For Hazardous Locations Sample Specification 1. General 1.1 The Explosion-Proof Convection Air Heater Model Number Rated Volts, Phase, Watts, shall be designed and constructed for use in hazardous locations. 1.2 For Groups B, C and D Check This Block The Heater shall be Underwriters Laboratories Inc. Listed and Canadian Standards Association Certified for constant use in Class I, Groups B, C and D, Division 1 or 2 hazardous locations, and National Electric Code minimum gas ignition temperature identification number T2A, 280 C (536 F) or T3A, 180 C (356 F). 1.3 For Groups C and D Check This Block The Heater shall be Underwriters Laboratories Inc. Listed and Canadian Standards Association Certified for constant use in Class I, Groups C and D Division 1 or 2 hazardous locations, and National Electric Code minimum gas ignition temperature identification number T2A, 280 C (536 F) or T3A, 180 C (356 F). 1.4 For European Models, Check this Block (1.8kW, 3.6kW, 4.5kW, 7.6kW, or 9.0kW) The heater shall be certified to be in conformity with the Council Directive 94/9/EC and labeled for II 3 EEx d II2G T2. Minimum gas ignition temperature 300 C (572 F). 1.5 For European Models, Check this Block. (1.6kW, 3.2kW or 4.0kW) The heater shall be certified to be in conformity with the Council Directive 94/9/EC and labeled for II 3 EEx d II2G T3. Minimum gas ignition temperature 200 C (392 F) T3. 1.6 The Heater shall be the natural convection type intended for wall mounting. 2. Construction 2.1 The back panel shall be designed to be easily mounted to the wall using keyhole slots. 2.2 The back panel shall be fabricated from 16 gauge steel, 9" (22.7) deep by 20" (50.8) high, coated with corrosion resistant polyester powder paint. 2.3 The back panel shall include perforations and a baffle to direct outside air between the panel and the mounting surface. 2.4 The front cabinet shall be easily removable by unthreading 4 bolts from threaded inserts. 2.5 The front cabinet shall be fabricated from 16 gauge steel, 9" (22.8) deep by 20" (50.8) high, coated with corrosion resistant polyester powder paint. 2.6 The front cabinet shall be sloped to prevent objects from being placed on top causing restricted air flow. 3. Elements 3.1 The elements shall be constructed of heavy duty resistance wire (80% Nickel, 20% Chromium) insulated by magnesium oxide refractory, which has been highly compacted to transmit heat and act as an electrical insulator. 3.2 The elements to be contained in a metal tube, which is then swaged to an O.D. of 1.25" (3.18). 3.3 The element assembly is inserted into a copper tube with 3" x 3.25" (7.6x 8.25) aluminum fins spaced at 48 fins per linear foot. 3.4 The finned assembly is to be mounted to the rear panel by polyester powder coated brackets. 4. Controls (Optional) 4.1 The CVEP shall include the following built-in control features (North American Approvals Only): operating temperature control magnetic contactor control transformer with 120V 24V secondary 4.2 The control components shall be factory installed, wired and tested. 5. Terminal Box (For units without transformer or contactor options) The terminal box shall be constructed of malleable iron or aluminum, to include a grounding lug and to be UL listed for Class I Hazardous locations (as indicated in 1. General Specifications above.) 4

Convection Heater For Hazardous Locations - CVEP Technical Data - CVEP without Controls (North American Approvals) Temperature Rating T3A 356 F (180 C) Group B, C and D Ordering Information Wt. kw BTU Volts Phase Amps Model No. Status* PCN (Lbs.) 1.6 5,500 3.2 11,000 4.0 13,600 208 1 7.7 CVEP-16-81-00-00 NS 088336 208 3 4.5 CVEP-16-83-00-00 NS 086844 240 1 6.7 CVEP-16-21-00-00 NS 086852 240 3 3.8 CVEP-16-23-00-00 NS 086860` 277 1 5.8 CVEP-16-71-00-00 NS 086879 480 1 3.3 CVEP-16-41-00-00 NS 086887 480 3 1.9 CVEP-16-43-00-00 NS 086895 575 1 2.8 CVEP-16-61-00-00 NS 086908 208 1 15.4 CVEP-32-81-00-00 NS 086916 208 3 9.0 CVEP-32-83-00-00 NS 086924 240 1 13.3 CVEP-32-21-00-00 NS 086932 240 3 7.7 CVEP-32-23-00-00 NS 086940 277 1 11.6 CVEP-32-71-00-00 NS 086959 480 1 6.7 CVEP-32-41-00-00 NS 086967 480 3 3.8 CVEP-32-43-00-00 NS 086975 575 1 5.6 CVEP-32-61-00-00 NS 086983 208 1 19.2 CVEP-40-81-00-00 NS 086991 208 3 11.1 CVEP-40-83-00-00 NS 087003 240 1 16.7 CVEP-40-21-00-00 NS 087011 240 3 9.6 CVEP-40-23-00-00 NS 087020 277 1 14.4 CVEP-40-71-00-00 NS 087038 480 1 8.3 CVEP-40-41-00-00 NS 087046 480 3 4.8 CVEP-40-43-00-00 NS 087054 575 1 7.0 CVEP-40-61-00-00 NS 087062 58 94 112 Temperature Rating T2A 536 F (280 C) Group B, C and D Ordering Information Wt. kw BTU Volts Phase Amps Model No. Status PCN (Lbs.) 1.8 6,156 3.6 12,300 7.6 24,000 9.0 30,700 120 1 15.0 CVEP-18-11-00-00 NS 028759 208 1 8.7 CVEP-18-81-00-00 NS 028767 208 3 5.0 CVEP-18-83-00-00 NS 028775 240 1 7.5 CVEP-18-21-00-00 NS 028783 240 3 4.4 CVEP-18-23-00-00 NS 028791 277 1 6.5 CVEP-18-71-00-00 NS 028804 480 1 3.75 CVEP-18-41-00-00 NS 028812 480 3 2.2 CVEP-18-43-00-00 NS 028820 208 1 17.3 CVEP-36-81-00-00 S 087070 208 3 10.0 CVEP-36-83-00-00 NS 087089 240 1 15.0 CVEP-36-21-00-00 S 087097 240 3 8.7 CVEP-36-23-00-00 NS 087100 277 1 13.0 CVEP-36-71-00-00 S 087118 480 1 7.5 CVEP-36-41-00-00 S 087126 480 3 4.3 CVEP-36-43-00-00 NS 087134 575 1 6.3 CVEP-36-61-00-00 NS 087142 208 1 36.5 CVEP-76-81-00-00 NS 085913 208 3 21.1 CVEP-76-83-00-00 S 085921 240 1 31.7 CVEP-76-21-00-00 NS 085930 240 3 18.3 CVEP-76-23-00-00 S 085948 277 1 27.4 CVEP-76-71-00-00 NS 085956 480 1 15.8 CVEP-76-41-00-00 NS 085964 480 3 9.2 CVEP-76-43-00-00 S 085972 575 1 13.2 CVEP-76-61-00-00 NS 085980 208 1 43.3 CVEP-90-81-00-00 NS 087230 208 3 25.0 CVEP-90-83-00-00 NS 087249 240 1 37.5 CVEP-90-21-00-00 NS 087257 240 3 21.7 CVEP-90-23-00-00 NS 087265 277 1 32.5 CVEP-90-71-00-00 NS 087273 480 1 18.8 CVEP-90-41-00-00 NS 087281 480 3 10.8 CVEP-90-43-00-00 NS 087290 575 1 15.7 CVEP-90-61-00-00 NS 087302 46 58 94 112 *Status: NS = Non-stock S = Stock Other sizes and configurations are available. Contact your local Chromalox Sales Office. To Order: Specify Quantity, Model Number, PCN, Volts and kw. 5

CVEP - Convection Heater For Hazardous Locations Technical Data - CVEP Certified Ratings for Europe Temperature Rating T3 200 C (392 F) Ordering Information Wt. Kg kw BTU Volts Phase Amps Model No. Status PCN (Lbs.) 1.6 5,500 3.2 11,000 4.0 13,600 208 1 7.7 CVEP-C-16-81-CE NS 220 1 7.3 CVEP-C-16-221-CE NS 240 1 6.7 CVEP-C-16-21-CE NS 380 3 2.4 CVEP-C-16-33-CE NS 400 3 2.3 CVEP-C-16-403-CE NS 415 3 2.2 CVEP-C-16-53-CE NS 480 1 3.3 CVEP-C-16-41-CE NS 480 3 1.9 CVEP-C-16-43-CE NS 600 3 1.5 CVEP-C-16-93-CE NS 208 1 15.4 CVEP-C-32-81--CE NS 220 1 14.5 CVEP-C-32-221-CE NS 240 1 13.3 CVEP-C-32-21-CE NS 380 3 4.9 CVEP-C-32-33-CE NS 400 3 4.6 CVEP-C-32-403-CE NS 415 3 4.5 CVEP-C-32-53-CE NS 480 1 6.7 CVEP-C-32-41-CE NS 480 3 3.8 CVEP-C-32-43-CE NS 600 3 3.1 CVEP-C-32-93-CE NS 208 1 19.2 CVEP-C-40-81-CE NS 220 1 18.2 CVEP-C-40-221-CE NS 240 1 16.7 CVEP-C-40-21-CE NS 380 3 6.1 CVEP-C-40-33-CE NS 400 3 5.8 CVEP-C-40-403-CE NS 415 3 5.6 CVEP-C-40-53-CE NS 480 1 8.3 CVEP-C-40-41-CE NS 480 3 4.8 CVEP-C-40-43-CE NS 600 3 3.8 CVEP-C-40-93-CE NS 26 (58) 43 (94) 51 (112) *Status: NS = Non-stock S = Stock Other sizes and configurations are available. Contact your local Chromalox Sales Office. To Order: Specify Quantity, Model Number, PCN, Volts and kw. Note: European ratings are not available with built in controls. Equipment marking: II 2 G EEx d IIB T3 6

Convection Heater For Hazardous Locations - CVEP Technical Data - CVEP Certified Ratings for Europe Temperature Rating T2 572 F (300 C) Ordering Information Wt. kw BTU Volts Phase Amps Model No. Status PCN (Lbs.) 1.8 6,156 3.6 12,300 7.6 24,000 9.0 30,700 120 1 15.0 CVEP-C-18-11-00-00-CE NS 208 1 8.7 CVEP-C-18-81-00-00-CE NS 208 3 5.0 CVEP-C-18-83-00-00-CE NS 240 1 7.5 CVEP-C-18-21-00-00-CE NS 240 3 4.4 CVEP-C-18-23-00-00-CE NS 277 1 6.5 CVEP-C-18-71-00-00-CE NS 380 3 2.7 CVEP-C-18-33-00-00-CE NS 480 1 3.75 CVEP-C-18-41-00-00-CE NS 480 3 2.2 CVEP-C-18-43-00-00-CE NS 208 1 17.3 CVEP-C-36-81-00-00-CE NS 208 3 10.0 CVEP-C-36-83-00-00-CE NS 240 1 15.0 CVEP-C-36-21-00-00-CE NS 240 3 8.7 CVEP-C-36-23-00-00-CE NS 277 1 13.0 CVEP-C-36-71-00-00-CE NS 380 3 5.5 CVEP-C-36-33-00-00-CE NS 480 1 7.5 CVEP-C-36-41-00-00-CE NS 480 3 4.3 CVEP-C-36-43-00-00-CE NS 575 1 6.3 CVEP-C-36-61-00-00-CE NS 208 1 36.5 CVEP-C-76-81-00-00-CE NS 208 3 21.1 CVEP-C-76-83-00-00-CE NS 240 1 31.7 CVEP-C-76-21-00-00-CE NS 240 3 18.3 CVEP-C-76-23-00-00-CE NS 277 1 27.4 CVEP-C-76-71-00-00-CE NS 380 3 11.6 CVEP-C-76-33-00-00-CE NS 480 1 15.8 CVEP-C-76-41-00-00-CE NS 480 3 9.2 CVEP-C-76-43-00-00-CE NS 575 1 13.2 CVEP-C-76-61-00-00-CE NS 208 1 43.3 CVEP-C-90-81-00-00-CE NS 208 3 25.0 CVEP-C-90-83-00-00-CE NS 240 1 37.5 CVEP-C-90-21-00-00-CE NS 240 3 21.7 CVEP-C-90-23-00-00-CE NS 277 1 32.5 CVEP-C-90-71-00-00-CE NS 380 3 13.7 CVEP-C-90-33-00-00-CE NS 480 1 18.8 CVEP-C-90-41-00-00-CE NS 480 3 10.8 CVEP-C-90-43-00-00-CE NS 575 1 15.7 CVEP-C-90-61-00-00-CE NS 46 58 94 112 *Status: NS = Non-stock S = Stock Other sizes and configurations are available. Contact your local Chromalox Sales Office. To Order: Specify Quantity, Model Number, PCN, Volts and kw. Note: European ratings are not available with built in controls. Equipment marking: II 2 G EEx d IIB T2 7

CVEP - Convection Heater For Hazardous Locations Model Numbers CVEP 16 1 1 30 42 CE (Europe Only) Thermo/Class 00 = no thermo B, C & D 40 = thermo in box B, C & D 42 = thermo C & D Voltage 1 = 120V 2 = 240V 3 = 380V 4 = 480V 5 = 415V 6 = 575V 7 = 277V 8 = 208V 9 = 600V Control Options 00 = no transformer no contactor 30* = (24V) transformer and contactor 31* = no transformer with contactor (24V) 32* = (120V) transformer and contactor 33* = no transformer with contactor (120V) 34* = no transformer with contactor (208/240V) 35* = no transformer with contactor (277V) Phase 1 = Single 3 = Three (Not available in 120 and 277V) Watts 16 = 1600W 18 = 1800W 32 = 3200W 36 = 3600W 40 = 4000W 45 = 4500W 76 = 7600W 90 = 9000W CVEP 16 1 1 30 42 Typical Model Number Explosion-Proof Convection Heater *North American Models Only PF306-2 PDS CVEP MARCH 04 8