Ionisation single-tube smoke detector for duct mounting

Similar documents
Installation instructions for the optical detector with built-in control unit, TBLZ-1-72-a GOLD/COMPACT

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

General Specifications

Installation Smoke Detector ELQZ , GOLD

Process Alarm Module RTA 421

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

Room controller. RC is a room controller from the Regio Mini series intended to control heating and cooling in a single zone.

Movement-based energy control

Room controllers with manual forced ventilation function

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

Sensors and Detectors

Line Smoke Detector LRMX

Refrigeration and Air Conditioning Technical leaflet. Electronic controller EKC 201 and EKC 301

On the job around the clock 24/7: Fire detection systems

COMPACT FLAME CONTROLLER CFC 1000

Dual Pressure Controls

Differential pressure gauge with electrical contact type Model: P650 series

Pre-programmed room controller with communication

COMPACT FLAME CONTROLLER CFC 2000

Sitron s CF Line of Flow Switch Monitors

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

PHOTOELECTRIC AMPLIFIER SERIES

4 Ó â. Contactor RTA421. Contactor with loop power supply for monitoring currentorvoltagesignals. Technical information TI074R/09/en

System 800 Addressable Fire Detection & Alarm System

More Precision. indusensor // Linear inductive displacement sensors

TECHNICAL SPECIFICATIONS BUTTONS

Smoke and Fire Curtains

1. Basic safety information 3 2. Proper use 3

Applications: 27. NETIChome mobile ios 28. NETIChome mobile Android. NETIChome basic elements

Advantages / Characteristics

User's Manual. Model VJQ8 Pulse to Analog Converter. (Multi-function) MODEL AND SUFFIX CODES CAUTIONARY NOTES FOR SAFE USE OF THE PRODUCT

Type 5347 (TR/STL), Type 5348 (TR/ST) and Type 5349 (STM/STL) Double Thermostats

Interface and EOL Modules 8

Electronic Standard Devices. Annunciator Relay. MR 11 and MRE 11 MR 21 and MRE 21

Busch-Watchdog presence. Overview and applications of presence detectors.

ECL Comfort V a.c. and 24 V a.c.

Index Arc Guard Systems. Arc Guard Systems. Arc Guard Systems Industrial Automation Supply - Tel:

Air. Pressure. Motion. nnnnnnnn

Fire Damper Interface (24V)

Static differential pressure measuring instruments. Pascal-ST/Z. for low measurement ranges Pa oder Pa

THERMAL MANAGEMENT THERMAL MANAGEMENT. Accessories: GV 400/500 or GV 600/700 AM 420P TRS 60, TRW 60, TWR 60, TKW 60 FILTER FANS SERIES LV

Conventional Smoke Detectors KFAPO

COMPACT FLAME CONTROLLER CFC 200 (Formerly 8.XX)

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

DUCTIMAX 2-8 kw. Medium available static pressure ducted hydronic units. Duct unit DUCTIMAX

BC-R10 Series. Burner Controllers

Products. World Edition

Complete packages with Software and Controller

Fire-Cryer. Plus Application Guide APPLICATION GUIDE FIRE EXIT VIMPEX. Shaping Alarm Technology

Dissolved Oxygen Measurement liquisys M COM 223 / 253

Lonworks Damper Interface Catalogue

Conductive Leakage detectors of the Leckstar range

Product data sheet AIRWIN additional modules Accessories AIRWIN

Conventional Fire Detection

Siemens aspirating smoke detector (ASD) for the addressed FDnet/C-NET detector line or for standalone operation

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

Roof Fan DVG EC. Smoke extraction and daily ventilation in one!

IP 55 (category II) IP 54 (category II) 4. Connection. 1. Basic safety information. 2. Proper use. 5. Installation. 3. Description.

Smoke Damper Interface (230V)

Smoke Fire Damper Interface (230V)

Fire Damper Interface (230V)

Pre-programmed room controller with communication

The new detector from Rafiki

It offers easy installation and the possibility for fast exchange of the sensor unit for service purposes.

II SL. Installation Guide. VOLTEX IMS64-2 Dual output indoor flush mount PIR motion detector IMS64-2

Vibracon LVL-A* Level limit switch for liquids, compact design

Room thermostats with LCD for wall mounting

INFRARED MODULATED BARRIERS

FLAME AMPLIFIER MODULE 3001

Light & Motion. Sample applications 259. Ceiling sensors. Wall sensors. Outdoor sensors. Motion. Light &

Topscan G3 Presence detector for automatic doors

ECL Comfort 300 / V a.c. and 24 V a.c.

Series Internal Detector

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

1. Product description

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

Residual current monitor RCM470LY/RCM475LY. for TN and TT systems (AC and pulsating DC currents)

DEB71. Earth Leakage Monitoring Relay. Benefits. Description

Leakage Detection. WaterAlarmSystems Fuel-oil/WaterAlarms. Safe protection for plants and buildings...leakage Detection Systems provided by BARTEC

Duct Air Quality Sensors

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

FDMM01S - FDMM02 - FDMM10- FDMM11S FDMM12 - Input / output mini modules

for relative humidity and temperature

FCS-320-TM Series Conventional Aspirating Smoke Detectors

Page 2 of 16. DOMEKT price-list PRICE-LIST Prices in POUND STERLING excluding VAT. Prices are valid for year 2018.

EFBW series - BiWire Ultra control panel

Retroreflective sensor with polarization filter

CONVENTIONAL >FIRE DETECTION C400 SYSTEM FIRE DETECTION

Input module, input/output modules

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Tel.: Fax:

Roof Fan DVG EC. Smoke extraction and daily ventilation in one!

1. Product characteristics 4 2. Safety 5 3. Proper use 5 4. Operation 6

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

The Right Temperature, Always THS Series Modular Thermostats

IR FLAME DETECTOR RIV-601/F

Parameterisable compact fault annunciator with permanent display

Movement Detector GJD 300

Retro-reflective Sensing range: 0mm to 2000mm

D-Tect 2 GJD300 Quad PIR Movement Detector

Speed and Frequency Seite 1 von 7

Transcription:

Detectors Ionisation single-tube smoke detector for duct mounting 600 mm venturi tube is included., incl. end resistor (not RAC(M)) 9...33 V DC (via ABV control unit). 24 V AC ±15 % for RAC(M) models. Normal operation: 11 ma at 24 V DC. Alarm condition: 50 ma at 24 V DC. Service alarm condition: 20 ma at 24 V DC. Duct IP54 SDD-S65 SDD-S50 SDD-S65-RAC SDD-S65-RACM SDD-S65-M SDD-S50-M Ionisation detector Ionisation detector with service alarm Ionisation detector with AC power supply and relay output only Ionisation detector with AC power supply and relay output only. With auxiliary fan. Ionisation detector with auxiliary fan Ionisation detector with auxiliary fan and service alarm TDS VR600 VR2000 spacer for insulated pipe ducts Venturi tube, 600 mm length (standard) Venturi tube, 2000 mm length Optical single-tube smoke detector for duct mounting 600 mm venturi tube is included., incl. end resistor (not RAC(M)) 9...33 V DC (via ABV control unit). 24 V AC ±15 % for RAC(M) models. Normal operation: 11 ma at 24 V DC. Alarm condition: 50 ma at 24 V DC. Service alarm condition: 20 ma at 24 V DC. Duct IP54 SDD-OE65 SDD-OE50 SDD-OE65-RAC SDD-OE65-RACM SDD-OE65-M SDD-OE50-M Optical detector Optical detector with service alarm Optical detector with AC power supply and relay output only. Optical detector with AC power supply and relay output only. With auxillary fan. Optical detector with auxiliary fan Optical detector with auxiliary fan and service alarm TDS spacer for insulated pipe ducts 150

Smoke detector for ceiling mounting 15...30 V DC (via ABV control unit) 0.14 ma (50 ma if an alarm occurs) Ceiling Service alarm S65-OE Optical detector - S50-OE-GA4 Optical detector with service alarm X S65 Ionisation detector - S50 Ionisation detector with service alarm X S-BP S-BPR-S50 S-BPR-S65 Socket for S50 and S65 detectors Socket for S50 detectors with built-in change-over relay (24 V AC) Socket for S65 detectors with built-in change-over relay (24 V AC) Control unit for smoke detectors Control units for the SDD, S50 and S65 series. Provides power supply and alarm handling for smoke detectors, with or without service alarm. Two relay contacts for alarm handling. 8 Number of modules 3 30 ma (70 ma if an alarm occurs), 1 VA (1.7 VA if an alarm occurs) DIN-rail Alarm outputs Service alarm ABV24-300/D Control unit 24 V AC/DC Two change-over contacts (smoke alarms) ABV24-S-300/D Control unit with service alarm 24 V AC/DC One change-over contact (smoke), one closing contact (smoke), one closing contact (service) ABV-300/D Control unit 230 V AC Two change-over contacts (smoke alarms) ABV-S-300/D Control unit with service alarm 230 V AC One change-over contact (smoke), one closing contact (smoke), one closing contact (service) - X - X 151

Smoke spray Gas for control of ionisation or optical smoke detectors. SS-260 Smoke spray, 260 ml Presence detector Detector providing a signal when someone enters the room. The detector has a pulse-detecting function that minimizes the risk of false alarms. Settable on/off delays and change-over relay. IR24-P Alarm output Temperature range Ambient humidity 24 V AC/DC, 0.1 VA 200 ma, 24 V DC, floating, change-over relay 15 ma -20 +50 C Max. 95 % RH IR24-PC Detection area IR24-P Wall 15 x 15 m, 110 angle IR24-PC Ceiling Height x 2.5 = coverage diameter, 25 angle 152

MISCELLANEOUS PRODUCTS Miscellaneous Thermometer Robust thermometer for duct mounting. Easy to mount. Can be adjusted to fit different duct sizes by means of a moveable fastening flange. A rubber seal prevents air leakage. Diameter Total length 65 mm 162 mm Temperature range T40-40...+40 C T60 0...60 C T100 0...100 C T40:25-40...+40 C Differential pressure manometer Simple, compact, easy-to-use filter manometer. MINI1200 is supplied with measuring fluid, pressure outlets and an adhesive label for noting down the filter type and the initial and final pressure drop. Pressure range Dimensions 0...1200 Pa 180 x 30 mm MINI1200 MINI1200:25 Manometer Manometer, 25 units Differential pressure manometer Device for high accuracy measurements. The manometer measures up to 600 Pa differential pressure with enhanced resolution between 0...200 Pa. Equipped with blow-out protection and a knob for zeropoint adjustment. Max. total pressure 100 kpa. MV600 is supplied with measuring fluid, pressure outlets, tubing, screws and an adhesive label for noting down the initial and final pressure drop. Pressure range 0...600 Pa Accuracy ±3 % Ambient temperature -45...+65 C Dimensions 210 x 140 x 33 mm MV600 Manometer 234

MISCELLANEOUS PRODUCTS Manometer accessories MM-F2 Blue measuring fluid (MINI1200) 1.05 g/cm 3, 500 ml MM-F3 Red measuring fluid (MV600) 0.786 g/cm 3, 30 ml MTU:25 Pressure outlet, black plastic. For 6 mm tubing, 25 pcs MTU:100 Pressure outlet, black plastic. For 6 mm tubing, 100 pcs MM-P:25 Plastic tubing Ø 6 mm. Transparent, 25 m. MM-P:100 Plastic tubing Ø 6 mm. Transparent, 100 m. IPP8:1000 Expansion plug, grey plastic, 8 mm, 1000 pcs IPP10:1000 Expansion plug, grey plastic, 10 mm, 1000 pcs IPP12:250 Expansion plug, grey plastic, 12 mm, 250 pcs T-ROR:100 Plastic T-branch joining piece, for 6 mm tubing, 100 pcs 14 235