When it Really Matters

Similar documents
High-Reach Extendable Turrets With Skin-Penetrating Nozzle

FIRE PROTECTION BUREAU ACCREDITATION AND CERTIFICATION PO Box Olympia WA (360) FAX: (360) AIRPORT FIREFIGHTER

Based on NFPA 1003: Standard for Airport Fire Fighter Professional Qualifications 2015 Edition

WILLIAM HICKS. MSc, CFEI, CFPS, IAAI-CFI, MIFireE, EFO, CFOD, F-IAFI. Associate Professor Eastern Kentucky University

SECURITY BLANKET Foam Fire Protection Products

Fire Suppression Performance of Manually Applied CAF and Other Water Based System

AIRPORT FIRE FIGHTER ID#: STANDARD:

Airport Firefighter Recertification Core Competency Task Book

Foam Products ENGLISH

71717 SERIES FLAMMABLE MATERIAL LOCATIONS

Aircraft Hangers. ft. (3,716 sq. m) per hangar construction type as defined by NFPA 409

Hazardous Material Safety Program

ATTIC FIRES. Part 3 HEAVY SMOKE SHOWING

STANDARD: 5.2.1(B) TASK:

Summary. firefighter training in Since that time the firefighter had attended semi-annual

FIRE AND FIRE FITTING By Mr. Prashant Sansare

Aircraft Hangars DESCRIPTION. A single fire area not larger than 40,000 sq. ft. (3,716 sq. m) per hangar construction type as defined by NFPA 409

Methodologies for Calculating Firefighting Agent Quantities Needed to Combat Aircraft Crash Fires

Technical Article. High Expansion Foam Systems. Martin Workman Viking Product Manager. September,

POSITION PAPER ON WATER MIST FOR FIRE FIGHTING APPLICATIONS

Public Comment No. 3-NFPA [ Chapter 7 ]

Best Practices. Foam Cleaning Fogging Spraying. Principles of Cleaning

An Overview Of Fluorinated Firefighting Foams: Past, Present & Future Presented by: Jerry Back, JENSEN HUGHES FOAM SYSTEM SYMPOSIUM

AIRCRAFT RESCUE AND FIREFIGHTING

The Combustion Process THE FIRE TETRAHEDRON FUEL TEMPERATURE

Self Expanding Foam Fire Suppression System SPECIFICATION SHEET Rev

IMPORTANCE of FIREGROUND VENTILATION PRACTICES and DYNAMICS IN FIREFIGHTING (PART I)

A HISTORICAL REVIEW OF FLUORINATED FOAM FIREFIGHTING AGENTS, PERFORMANCE REQUIREMENTS/ ENVIRONMENTAL SAFEGUARDS REVIEW

A.U.P.C.I ASOCIACIÓN URUGUAYA DE PROTECCION CONTRA INCENDIO AUPCI

The Effect of Large Orifice Sprinklers on High-Challenge Fires

& Fire Extinguisher Training

Aerial Urban Fire Suppression. Information proprietary to Simplex Aerospace and shall not be copied without express permission from Simplex

Using Fire Extinguishers. Leaders Guide and Quiz

Hazard Control Technologies, Inc.

WATER MIST CONVENTION AND EXHIBITION

"USING FIRE EXTINGUISHERS"

SUBJECT FIRE OPERATIONS GUIDELINE (F.O.G.) #F510 Issued: 1/2014 Last Revision: 1/2014 Pages: 9 By Order Of: J.S. Thompson, Fire Chief

Mist-Tech Fire Fighting Equipment

FireIce & FireIce Shield F.A.Q.

AFRL-ML-TY-TR

STANDARD OPERATING PROCEDURES AIRCRAFT RESCUE FIRE FIGHTING RESPONSES MEMPHIS INTERNATIONAL AIRPORT. ALERT I RESPONSE (Precautionary Emergency)

Class Outline NFPA 1003/ProBoard Basic Aircraft Rescue Firefighting

Rescue and Fire-Fighting Management of Extinguishing Agents

International Safety Guide Chapter 30 for Inland Navigation Tank-barges and Terminals. Chapter 30 FIRE-FIGHTING

Technical Article. Foam Systems - Low Expansion, Medium Expansion, High Expansion. Martin Workman, Product Manager Special Hazards Division

TECHNICAL MANUAL OPERATOR'S, ORGANIZATIONAL AND DIRECT SUPPORT MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST)

Fire Safety. Presenter, Kevin V Coleman September 14 th 2016

TUNPROTEC. Active Tunnel Fire Protection

Significant Advancements in Water Based Fire Suppression for Storage Occupancies

STORED PRESSURE YES TEST STANDARDS: CAN/ULC S504 & ANSI/UL 229 CAN/ULC S508 & ANSI/UL 711. Available Options: Stationary Design Tow Loop

REPORT DOCUMENTATION PAGE

High flying fire protection HI-FOG for aircraft hangars

Staffing Concerns Regarding ARFF Apparatus EXECUTIVE LEADERSHIP

EASTERN ARIZONA COLLEGE Fire Department Operations II

Tel Web: dyayan.com

Title: Fire Protection Effective Date: 7/1/2013 Control Number: THG_0039 Revision Number: 1 Date: 10/23/2015 Annual Review Completed: 5/13/2015

Fire fighting with fast deployment units. CRISTANINI Spa Via Porton 5, Rivoli Veronese, ITALY

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

1 Aviation English Vocabulary Level 4 to 5

Fire extinguishers. Amicus guide

Safer Fire Fighting. Efficient Fire Fighting. Saving Environment

Today, we re going to talk about emergency action and fire prevention. We hope we never have to face an emergency situation like a fire in our

Portable Fire Extinguishers

ONE SEVEN FAST. EFFECTIVE. SAFE. ENVIRONMENTALLY FRIENDLY

Township Of Jackson, Fire District 3, Station 55 Standard Operating Guidelines FIRE GROUND STRATEGY

Fire Safety. Version 1.0

Figure 1. Structure Used For the Simulations.

HKIE CPD Training Course (II) 23, 25 June and 7, 9 July 2009

Cloud Tech Dust Suppression System

TRAINING BULLETIN September 1, 2010 PURPLE K DRY CHEMICAL EXTINGUISHER 1. INTRODUCTION

WAS STARTED BY CARLOS BAHAMONDES MASAFIERRO

Effects of Ultra-High Turndown in Hydronic Boilers By Sean Lobdell and Brian Huibregtse January 2014

ATTIC FIRES. Part 2 LIGHT SMOKE SHOWING

White Paper. The Victaulic Vortex Fire Suppression System Fire Suppression for Electrical and Electronic Applications

Hot Topics In ARFF. Duane Kann Fire Chief Orlando International Airport. Jason Graber Battalion Chief Metropolitan Washington Airport Authority

Efficient Steam System Design

SKILL VERIFICATION BOOK FIREFIGHTER I MODULE II FIRE PROTECTION BUREAU. Assigned to: Name:

A Study on Cooling Rate with Blade and Sound Fire Extinguisher

The Theory and Practice of Variable Orifice in Automatic Sprinkler Systems

GREEN SHEET. Los Angeles Fire Department. Informational Summary Report of Serious LAFD Injuries, Illnesses, Accidents and Near-Miss Incidents

An experimental study of the impact of tunnel suppression on tunnel ventilation

Driver/Operator ARFF

Sprinklers Modeling for Tunnel Road Fire Fighting

Safety is more than just being careful: it

TECHNICAL DATA 3% AR-AFFF

AFRL-RX-TY-TR

TWO TIMES THE FIGHT Twin-Agent Fire Suppression Systems

2. Gas B. The column of hot gases, flames, and smoke rising above a fire; also called convection column, thermal updraft, or thermal column

Water Mist-Based Fire Suppression Modelling of an Office Space Scenario

Public Input No. 2-NFPA [Chapter F]

A comprehensive systems-level approach in cabin design minimizes fire potential and helps ensure passenger safety. aero quarterly qtr_04 11

June 2013 Safety Meeting Fire Extinguishers Part II

Full Scale Battery Tests

Avionics/Systems Policy Updates - Small Airplane Directorate

Driver Resource Manual Unit 6 Emergency Evacuation

Firefighting Group Water Systems. 1. Spray Nozzle 2. Fire Hose Box and Fire Hose Box 3. Barrel Fire Hydrant 4. Water Monitor

More heat energy means more of what type of energy? Does the mass change? So, what must change? What is the same in both containers?

TECHNICAL DATA OBSOLETE

Jet Compressors. Circulate Steam Boost Low-Pressure Steam Compress and Mix Gases in Desired Proportion

TITLE: Offensive and Defensive Operations

Transcription:

When it Really Matters 1

CURRENT TOOLS OF THE TRADE Crash Rescue Equipment Service, Inc. Dallas, Texas ARFF vehicles have evolved to provide safe, rapid response to get agent transported from the fire station to the fire. I am going to talk to you today about getting that agent off of the truck and onto the fire in the most efficient ways. In order to talk about the advancements in agent application technology, we need to look at the past. 2

PRIMARY TURRETS, HOW THEY EVOLVED Agent Validation Tests 1962 - NAFEC Extensive testing was conducted in 1962 at the FAA facility that went by the name of National Aviation Facility and Experimental Center (NAFEC) and by the Naval Research Lab at China Lake. These test established the turret performance standards for NFPA, FAA and ICAO. 3

MANUAL CONTROLS PROTEIN FOAM At the time the tests were conducted, protein foam and manually operated air aspirated turrets were the technology of the day. 4

POWER CONTROLS AFFF FOAM These basic roof turret designs have evolved to include power operation and joystick controls. The large air aspirated nozzles have given way to smaller non air aspirated nozzle, more suited for AFFF foam. However, the basic performance standards have not changed. 5

FUSELAGE SKIN GROWTH In the mean time, aircraft size and fuel loads have increased. 6

Fuel Load Liters 300000 250000 200000 150000 100000 50000 0 737 747 A-380 The B777 hold 8 times more fuel then the B737, and the A 380 hold 13 times more fuel then the B737. The 737 holds 6,295 gallons/23,828 liters of fuel. The 777 holds 47,890 gallons/181,270 liters of fuel. The A-380 holds 78,830 gallons/298,600 liters of fuel. How much more fire extinguishing agent will you need? Technology can make up some of the difference. 7

Practical Critical Area =.667 of the Theoretical Critical Area 6m 24m Wind = 16 to 19 Kmph The Practical Critical Area (PCA) formulas established in the past were based on the length and width of the aircraft. It was assumed that as aircraft increased in fuselage size, the proportions of the length and width would increase accordingly. We now know that aircraft, like the new Air Bus 380, carry twice as many passengers and 10 times as much fuel as the Boeing 737, but it has only a slightly larger footprint. There are efforts underway to re-look at the PCA formulas. This is critical for aviation fire fighting because the PAC determines the amount of agent required for the airport index. 8

APPLICATION DENSITY Application density is gallons per minute (GPM) applied per square foot (SF) of fuel surface. AFFF/FFFP foam requires an application density of.07 GPM/SF The standards committee doubled this to.13 GPM/SF to account for inefficiencies. The application density is a very reliable number. For AFFF the rate of.07 GPM/SF is the maximum effective rate to extinguish any size of pool fire in 60 seconds. The gallon per minute flow rate then becomes a factor of the square foot size of the pool area (PCA). An application rate of more than.07 GPM/SF will not extinguish the fire faster. These are two important numbers that we will refer to later. 9

AIRPORT CRASH STATISTICS IFALPA NTSB-FAA FAA-ICAO Major Aircraft Fire Accident Data On 53 accidents (NFPA, ICAO, Category 6-96 Indexes) between 1978-2003 approximately 3.9 times the amount of agent specified in NFPA 403 was used, 5.7 times ICAO requirement. Fire control times averaged 78 minutes and extinguishment averaged 2 1/2 hours. Three to five times as much agent as expected has been required to extinguish aircraft fires. And, this is with an application rate of double the maximum application density. 10

Vehicle Performance is only the Beginning Shouldn t t we place more emphasis on Agent Management? It s not how fast you get there. It s what you do with your agent once you are there. 11

MISAPPLICATION OF AGENT Applying agent at excessive rates. Applying agent to the exterior of the aircraft when the fire is on the interior of the aircraft. Applying agent to areas not involved with the fire (except to protect exposures). Not utilizing all of the agents carried to the fire. One of the reasons the quantities are so far off is the misapplication of agent. Political Foam It looks good on CNN. 12

STRONGER AIRCRAFT PRESENT MORE DIFFICULT FIRES 33,000 gallons of agent used Aircraft today are stronger and safer. They are less likely to break up upon impact. If the fire propagates to the interior, you have a large confined space interior fire. Using conventional turrets, you had to wait until the fire broke through the skin to get large volumes of agent onto the fire. 13

RAIN DROP APPROACH Forty-five degree application results in the greatest reach for roof turrets but agent loss occurs in the fire plume and disrupts the surface of the fuel by splashing the film surface build-up process. Elevating the turret delivery system angles is very inefficient and can increase extinguishment times by 100% or more. Another reason for ineffectiveness of the conventional roof turret is the application techniques developed in the 1960 s testing. Raindrop is a term used to describe raining foam down on the fire from a distance. This technique was dictated by the protein foams of the time. Protein foam has very little burn back resistance. If the foam cover is broken, the exposed fuel can quickly reignite. The raindrop technique was developed to build up a thick foam blanket on the fuel without disturbing the surface. AFFF foams solved the burn back problem, but if applied by the raindrop technique, much of the agent goes up in the heat plume. 14

DIRECT ATTACK Point of attack application from roof turrets accelerates agent but leads to over spray on windshield, which causes waste of agent. Because of obscured vision, fire fighters could not see what effect the agent was having on the fire. Poor visibility caused the target to be directly obscured by the agent plume and by agent blow-back that was deposited on the vehicle windshield. Fire fighters could neither see how effective they were, nor where the agent was going. A more direct agent discharge solves the heat plume problem, but can disturb the fuel surface creating an even larger fire. 15

What Is A High Reach Extendable Turret? An articulating and/or telescoping aerial device mounted on the ARFF Vehicle. It provides extended vertical & horizontal positioning of the turret. This tool took the turret off of the roof and provided a range of motion to position the turret from ground level to over 50 foot elevation. 16

High Reach Extendable Turrets Allow Agent To Be Applied From Many Different Positions LOW ATTACK HIGH ATTACK The FAA Technical Center and the United States Air Force Research Lab took on the task of learning the potential of this new technology. The Extendable Turret had the capability of positioning the nozzle high or low. At first it was thought that the higher the reach, the more effective it would be in fighting fires. However, there was no significant improvement in extinguishment times. As the nozzle was lowered, extinguishment times improved rapidly. 17

LOW ANGLE ATTACK Parallel to ground application accelerates agent across the fuel surface. This type of low ground attack allows a 10 degree power cone spray effect that disperses agent more rapidly. Test summary and conclusions: Optimum LFA crash vehicle approach mode conditions are frontal and tail approach, 0.13 GPM/SF AFFF application rate, 0 o, seat of the fire, agent delivery angle, delivered as low as possible. The low application approach proved to be the most effective. How many of you have been trained on using portable fire extinguishers? Were you taught to direct the stream at the base of the fire in a sweeping motion? The same technique proved to be true for large fires as well. 18

NOSE/TAIL APPROACH Slides would be in the red zone! This happens to be the area that you are tasked to protect. Utilizing high reach extendable turret technology allows you to protect the entire aircraft by positioning on the nose and/or tail (depending on the size of the aircraft). Conventional roof turret approach could require up to four vehicles (two each side) for the same coverage. 19

FIRE TEST COMPARISON The top view is a conventional roof turret flowing at 500 gpm. This equates to and application density of.13 GPM/SF per the standards, but twice the theoretical rate. The lower view is the Extendable Turret flowing 250 gpm, equal to the application density of.07 GPM/SF. The net result is that the low positioned nozzle extinguishes the fire in half the time using half the agent. This test was repeated dozens of times with the same results. 20

High Performance Bumper Turrets Efficient Low Ground Attack As a result of the previous tests, it only made since to move the roof turret to a lower position on the vehicle to get the nozzle closer to the ground. 21

OPERATOR VISIBILITY Remember the early slide showing manual operated turrets and protein foam? Look where the operator is positioned. Note the view he has of the fire. Because of safety and manpower issues, turret controls were moved inside the cab. Foam agent was changed to AFFF. Now this is the view the operator has of the fire. How effective is he going to be in getting the agent on the seat of the fire. 22

IMPROVED OPERATOR VISIBILITY Look at the improved visibility the operator has when looking over the water/foam flow instead of under it or placing the stream from an extendable boom far forward increasing the fields of view. 23

FAA Report www.airtech.tc.faa.gov Safety Downloads 24

Approach Mode Large Scale AFFF Delivery Tests Fire Surface 3, 850 SF Average 90% Fire Extinguishment Time (Sec) Delivery Method Raindrop Raindrop Seat of The Fire 45 o 30 o Average 0 o Roof Turret Bumper Turret Low Flow@ 0.07 GPM/SF 56 43 50 31 High Flow @0.13 GPM/SF 50 42 46 27 Total Extinguishment Times 116 85 96 53 This is a comparison of roof turret performance vs. a low position turret. You will note that extinguishment times for the low mount turret are about half that of the roof turret. Another interesting item is that there is not a significant change in effectiveness whether flowing at a.13 GPM/SF or.07 GPM/SF. Remember, applying AFFF at rates above.07 GPM/SF does not extinguish the fire faster. However, at the higher flow rate, we do use up the agent on the vehicle much faster. 25

PIERCING NOZZLE ON EXTENDABLE TURRET In the early 1990 s, a piercing nozzle was attached to the extendable turret. With hydraulic piercing power and a 50 foot articulating and telescoping arm, the piercing nozzle could quickly penetrate almost anywhere on the aircraft. Since it was not hand held, flows over 300 gpm were possible. 26

PIERCING NOZZLE TESTING Air Bus 380 Glare Material The FAA Technical Center took on the responsibility of testing this technology. Early theories were that the boom mounted piercing nozzle could be used to penetrate a fuselage and create a fire block to contain the interior fire to one end of the aircraft. Hundreds of piercing tests were conducted to see what materials could be pierced and where was the best place to penetrate. 27

FULL SCALE FIRE TESTS A full scale aircraft fire test was conducted at San Antonio in 1993. The aircraft was an older model 707 without flame retardant materials. The test scenario was to have an exterior fire under the tail propagate into the interior. Instruments inside the aircraft were monitoring temperatures. When the ceiling temperature reached 600 degrees, the piercing nozzle was to penetrate at a pre-determined point and block the fire from spreading to the rest of the plane. However, the wind was blowing wrong and forced some of the flames against the plane s skin. At the four minute mark the skin burned through dropping the galley and giving oxygen to the interior fire. Almost immediately a flash over occurred and the complete interior caught on fire. Ceiling temperatures went to 1200 degrees. The piercing nozzle was brought into position and started pumping 375 gpm into the interior for 1 minute, 45 seconds. The entire aircraft interior was extinguished. 28

Interior Fire Fighting Video A view of what the piercing nozzle looks like inside the aircraft. This is the same aircraft shown in the previous video. Note how the fire damage was mostly in the ceiling area where the flash over occurred. Survivable conditions were maintained at the seat back level and below. 29

HOW WELL DO THESE TECHNOLOGIES WORK? Less than 6000 gallons/ 22,710 liters of agent used In December of 2003 a fully loaded cargo plane lost its right side landing gear and slid off the runway. About 4,000 gallons of fuel was on board. The fire or the crash caused the transfer valve to fail allowing all the fuel from the left side wing to also feed the fire. The nose of the aircraft was in a steep ravine not readily accessible by ARFF vehicles. Less than 5,000 gallons of agent was used to extinguish the fire. 30

ENCAPSULATED DRY CHEMICAL NOZZLES The fire fighting technique involves laying down a foam blanket to control the pool fire and cool the structure. Then focusing on the running fuel fires with bursts of dry chemical, keeping the foam flow constant. Short burst of dry chemical when directed on target are very effective. It is important to minimize the amount of dry chemical used as it can cause a breakdown of the foam blanket. At the end of the video, you will see what dry chemical looks like when it is not encapsulated. The operator shut off the water/foam flow before turning off the dry chemical. 31

WATER MIST NOZZLES High pressure water mist One of the newest (and oldest) technologies is water mist. Foam attacks the fire triangle by removing oxygen. Water mist attacks the fire triangle by removing the heat. Breaking water droplets into a fine mist exposes a much larger water surface area to the heat of the fire. The fine mist will cool 100 times faster than conventional size water droplets and almost all of the water goes to extinguishment. There is very little run-off and the agent flow rates are very small compared to conventional nozzles. Also, this is an environmentally very clean agent. High pressure, low volume nozzles have been around since the 1940 s. However, they were not able to break the water droplets fine enough to create mist that was comparable in fire fighting to that of large volume fog nozzles. Two types of misting nozzles are under development. One technology utilizes ultra high pressure to create the mist and the energy necessary to transport the mist over distance. Ultra high pressure is in the range of 1,000 to 2,000 psi. Water is forced through a small tapered orifice under high pressure. This forces the water to accelerate to a very high velocity. As it exits the nozzle into the low atmospheric pressure, it vaporizes into a fine mist still traveling at high velocity. The Second Type uses high pressure air to vaporize the water into small droplets and this low pressure vaporized water is carried to the fire source. Much less nozzle back pressure is felt at the hand line or turret attachment. 32

Compressed Air Foam Comparison Liters 1600 1400 1200 Gillette Shaving Cream 1000 800 600 400 200 0 Budweiser King of Beers Water Standard Foam CAFS Foam ARFF vehicle compressed air foam systems are typically set between 15 and 20 to 1 expansion ratios. Thus, a compressed air foam system will produce four times as much foam from a given amount of water as a conventional foam system. NOTE FOR BOB Can of Beer and Shaving Cream. 33

High Energy Cold Foam (CAF) System Video Compressed air foam experiences an energy boost from the air injection. Low gpm flows of compressed air foam will travel as far as high gpm flows of conventional foam. To produce 1,000 gpm of finished foam, conventional foam nozzles must flow about 250 gpm of liquid (expanded 4 to 1). To produce 1,000 gpm of compressed air foam we must flow 50 gpm of liquid (expanded 20 to 1). This video is a compressed air foam system installed on a P-19 ARFF vehicle. The standard foam system is maintained. The operator can choose between conventional foam or compressed air foam. The fire fighting scenario might be to use standard foam to knock the fire down and switch to compressed air foam to build the foam blanket and protect exposures. As you can see, compressed air foam will cling to vertical surfaces. 34

APPLICATION DENSITY IS 1/3 THAT REQUIRED FOR CONVENTIONAL FOAM Density is.024 gpm/sq.ft. Remember the application densities we have discussed?.13 GPM/SF is established by the standards,.07 GPM/SF is the maximum effective rate for AFFF foam. The Air Force conduced fire tests using compressed air foam. They concluded that an application density of.024 GPM/SF of compressed air foam was as effective as the.07 GPM/SF application rate of conventional foam. This means that compressed air foam is about 2 or 3 times more effective that conventional application. 35

REDUCING AGENT DISCHARGE RATES 1,000 gpm/ 3,785 lpm at an application density of.13 GPM/SF (current roof turret standard) /High Flow 500 gpm/ 1,893 lpm at an application density of.07 GPM/SF (low angle attack) /Low Flow 166 gpm/ 628 lpm at an application density of.024 GPM/SF (compressed air foam) /Low Angle Attack We have essentially taken a vehicle that flows 1000 gpm/ 3,785 lpm at a.13 density application, moved to 500 gpm/ 1,893 lpm using the low angle approach at.07 density application and now can reduce to 166 gpm/ 628 lpm using compressed air foam all with the same fire fighting capability. If you add injected Halotron or encapsulated dry chemical, the flow rate could be further reduced. With these new technologies, your 1500 gallon/ 3,678 litter truck could have the fire fighting capability of a 9,000 gallon/ 34,065 litter truck using old roof turret performance standards. This is a theoretical figure. But an improvement of a factor of 3 is easily achievable. 36

AIR ASPIRATING NOZZLES Air aspirating nozzles are not dead. We don t know what the future of foam products will be. Air aspirated nozzle may be necessary. A new compact version of the air aspirated nozzle uses new technology to increase the aeration without the need for the long barrels. This 1,000 gpm nozzle is about 20 long. 37

Agent Management New tools are available to advise the operator the status of the agent on board. We have shown that attacking with a high flow rate may not be any more effective than a low flow rate. A high flow rate on the primary turret will empty the vehicle in two minutes. This display advises the operator how many minutes and seconds of agent are left at the current flow rate. It allows him to make a decision as to how to use the remaining agent or to switch to a lower flow rate to be more effective. Once the agent is gone, the fire will gain control during the refill process. It is much better to use the agent on board to its maximum effectiveness. 38

Agent Management The Agent Management System provides critical information to the operator regarding agent discharge time remaining, turret flow status and water tank level. The system is located in direct view of the operator so he can keep focused on the fire fighting effort while getting the information he needs. 39

LARGER AIRCRAFT REQUIRES MORE STAND-OFF DISTANCE ARFF vehicles will not be able to get as close to the aircraft as in the past. 40

EXTENDED REACH TURRETS Extendable turrets are increasing in size to accommodate the larger aircraft. The increased height is not as important as the increased reach. Longer stand-off distances are required for double deck evacuation slides and vehicle protection in event of landing gear collapse. This particular design features two nozzles. A high volume nozzle at the 50 ft. level on the upper boom and a low volume nozzle at the tip. The low volume nozzle is used for engine, wheel/brake and interior fires. The high volume nozzle is used for large spill fire control. 41

It Is The Aviation Fire Fighting Responsibility To. Do a risk assessment. Recognize there is a problem. Seek new & improved technology to better improve fire fighting capabilities and minimize risk. Train in the effective use of this technology. 42

HOW DO I GET THE NEW TECHNOLOGY? You have to take the initiative. Specify the technology that best accomplishes your goals. Add requirements to your new truck specifications and purchases. Investigate what can be upgraded on existing vehicles. 43

This Technology Is Spreading Around the World 44

Crash Rescue Equipment Service, Inc www.crashrescue.com 45

46