HOYME CONTROLS
|
|
- Imogen Green
- 5 years ago
- Views:
Transcription
1 INDEX HAC SERIES UNIVERSAL INLINE DAMPERS HANSEN MOTOR DRIVE UNIVERSAL AIR CONTROL HOM SERIES FRESH AIR DAMPERS COMBUSTION AIR CONTROL COMMERCIAL APPLICATIONS (WHERE BTUs EXCEED 400,000) INTRODUCTION Expert Service. Quality Products. Since ECCO Supply 7-1
2 AIR CONTROL SOLUTIONS BY HOYME MANUFACTURING INC. Building an energy efficient house always starts with high insulation values and the tight control of infiltration air. HOYME Motorized Air Control Dampers economically provide buildings with: Improved energy efficiency (through positive air control) Extended and maintenance free air control life Assured occupant safety Enhanced comfort Reduced stress to mechanical systems (during extreme weather) HOYME manufactures Motorized Dampers that are ideal for controlling: Combustion air Make-up/replacement air Ventilation air Backdraft of air exhausting devices Zoning of heating, cooling or ventilation air Air conditioning economizer operations HOYME Manufacturing Inc. is a Canadian designer and manufacturer of Motorized Air Control Dampers for the HVAC Industry. To learn more about the uses and benefits of these fine products, please contact your ECCO Supply Sales Representative. HAC SERIES UNIVERSAL INLINE DAMPERS Applications Fresh air Exhaust air Zone air Hot air UNIVERSAL AIR CONTROL DAMPERS 1 Motor Power Open C HAC-0210-OPO 2 3 C HAC-0310-OPO HAC-0410-OPO HAC-0510-OPO HAC-0610-OPO HAC-0710-OPO HAC-0810-OPO 8 5 C HAC-0910-OPO 9 5 HAC Series HOM Series 1 Motor Power Closed C HAC-0210-OPC 2 3 C HAC-0310-OPC 3 3 C HAC-0410-OPC 4 3 C HAC-0510-OPC HAC-0610-OPC 6 4 C HAC-0710-OPC 7 4 C HAC-0810-OPC 8 5 C HAC-0910-OPC ECCO Supply
3 HAC SERIES UNIVERSAL INLINE DAMPERS (cont'd) UNIVERSAL AIR CONTROL DAMPERS (cont'd) 1 Motor with End Switch Power Open C HAC-0210-SPO 2 3 C HAC-0310-SPO 3 3 C HAC-0410-SPO 4 3 C HAC-0510-SPO HAC-0610-SPO 6 4 C HAC-0710-SPO HAC-0810-SPO 8 5 C HAC-0910-SPO Motor with Relay Power Closed C HAC-0411-OPC HAC-0511-OPC HAC-0611-OPC 6 4 C HAC-0711-OPC 7 4 C HAC-0811-OPC 8 6 C HAC-0911-OPC Motor with End Switch Power Closed HAC-0210-SPC to HAC-0910-SPC 1 Motor with Relay Power Open HAC-0411-OPO to HAC-0911-OPO 1 Motor with End Switch and Relay Power Open HAC-0411-SPO to HAC-0911-SPO 1 Motor with End Switch and Relay Power Closed HAC-0411-SPC to HAC-0911-SPC 1 Motor Designed for Heat with 10% Bypass Power Open HAC-0210-OPO-H to HAC-0910-OPO-H 1 Motor Designed for Heat with 10% Bypass Power Closed HAC-0210-OPC-H to HAC-0910-OPC-H ECCO Supply 7-3
4 HAC SERIES UNIVERSAL INLINE DAMPERS (cont'd) UNIVERSAL AIR CONTROL DAMPERS (cont'd) 1 Motor with End Switch Designed for Heat with 10% Bypass Power Open HAC-0210-SPO-H to HAC-0910-SPO-H 1 Motor with End Switch Designed for Heat with 10% Bypass Power Closed HAC-0210-SPC-H to HAC-0910-SPC-H 1 Motor with Relay Designed for Heat with 10% Bypass Power Open HAC-0411-OPO-H to HAC-0911-OPO-H 1 Motor with Relay Designed for Heat with 10% Bypass Power Closed HAC-0411-OPC-H to HAC-0911-OPC-H 1 Motor with End Switch and Relay Designed for Heat with 10% Bypass Power Open HAC-0411-SPO-H to HAC-0911-SPO-H 1 Motor with End Switch and Relay Designed for Heat with 10% Bypass Power Closed HAC-0411-SPC-H to HAC-0911-SPC-H 1 Motor Insulated Power Open HAC-0210-OPO-L to HAC-0910-OPO-L 1 Motor Insulated Power Closed HAC-0210-OPC-L to HAC-0910-OPC-L 1 Motor with End Switch Insulated Power Open HAC-0210-SPO-L to HAC-0910-SPO-L 1 Motor with End Switch Insulated Power Closed HAC-0210-SPC-L to HAC-0910-SPC-L 1 Motor with Relay Insulated Power Open HAC-0411-OPO-L to HAC-0911-OPO-L ECCO Supply
5 HAC SERIES UNIVERSAL INLINE DAMPERS (cont'd) UNIVERSAL AIR CONTROL DAMPERS (cont'd) 1 Motor with Relay Insulated Power Closed HAC-0411-OPC-L to HAC-0911-OPC-L 1 Motor with End Switch and Relay Insulated Power Open HAC-0411-SPO-L to HAC-0911-SPO-L 1 Motor with End Switch and Relay Insulated Power Closed HAC-0411-SPC-L to HAC-0911-SPC-L HANSEN MOTOR DRIVE Return Spring Power Open C HAC-0650-OPO 6 5 C HAC-0850-OPO 8 5 C HAC-0950-OPO HAC-1050-OPO 10 7 C HAC-1250-OPO 12 8 Return Spring Power Closed HAC-0650-OPC to HAC-1250-OPC Return Spring and End Switch Power Open HAC-0650-SPO to HAC-1250-SPO Return Spring and End Switch Power Closed HAC-0650-SPC to HAC-1250-SPC Return Spring and Relay Power Open HAC-0651-OPO to HAC-1251-OPO Return Spring and Relay Power Closed HAC-0651-OPC to HAC-1251-OPC NOTE: ECCO Supply 7-5
6 HOM SERIES FRESH AIR DAMPERS Applications Residential Commercial Gas code certified COMBUSTION AIR CONTROL One Appliance Models HOM-0411-SF HOM-0511-SF HOM-0611-SF HOM-0711-SF HOM-0811-SF1 8 6 C HOM-0911-SF1 9 6 Two Appliance Models C HOM-0412-SF HOM-0512-SF HOM-0612-SF HOM-0712-SF HOM-0812-SF2 8 6 C HOM-0912-SF2 9 6 COMMERCIAL APPLICATIONS (WHERE BTUs EXCEED 400,000) Slave to One SF1 Series or SF2 Series HOM-0410-SO1 to HOM-0910-SO1 Slave to Two SF1 or SF2 Series HOM-0411-SO2 to HOM-0911-SO2 Replacement Control Body Only F1 and F2 Series Replacement Chassis Unit Only F1 all sizes F2 all sizes ECCO Supply
UP (run) position for normal operation of the damper. For details on the use of the Test/Run switch, see Troubleshooting Procedure.
Installation Instructions for HMI HOYME Motorized COMBUSTION AIR CONTROL DAMPER VERTICAL MOUNT 24Vac Series HOM Interlocks With Safety Control Systems Gas, Oil, Boilers & Furnaces THIS INSTALLATION SHALL
More informationECONOMIZER CONTROLLER ET-858
ECONOMIZER CONTROLLER ET-858 One of the challenges that HVAC design engineers face is developing an air conditioning distribution system to deliver outdoor air to the occupants of a building. This task
More informationMultiFamily Ventilation Updates: ASHRAE 62.2, Best Practices and Practical Applications RESNET Conference Atlanta, GA
MultiFamily Ventilation Updates: ASHRAE 62.2, Best Practices and Practical Applications 2014 RESNET Conference Atlanta, GA Ray Ivy and Mike Barcik Southface 1 About Southface 2 Topics Covered How to use
More informationUniform Dwelling Code 2017 Updates SPS 323
Uniform Dwelling Code 2017 Updates SPS 323 Lenny Kanter UDC Engineering Consultant Department of Safety and Professional Services 608 261 6541 voice 608 267 9723 fax robert.kanter@wi.gov Plan Review and
More informationExhaust Makeup Air System What goes out, must come in
Exhaust Makeup Air System What goes out, must come in Exhaust Makeup Air System What goes out, must come in so says the building code 7 4 8 Wall Intake Hood, FML Shutoff Damper, ADC Makeup Air Fan, FG
More informationRESNET HERS Rater Sample Test Questions 2
RESNET HERS Rater Sample Test Questions 2 1. Which of the following is the best device for removing standing water from a crawl space? A. Dehumidifier B. Sump pump C. Air-to-air heat exchanger D. Crawl-space
More informationEnthalpy Efficiency[%] Efficiency [%] L M H L M H L M H L M H L M H L M H ,
ERGO Download lnorcm uy via 2 uxiliary Equipment and ccessories Heat and energy recovery ventilator ERGO has high efficient counter flow heat exchanger. Total heat exchanger is made of ER paper which is
More informationJob Name Control Systems Description Date
Job Name Control Systems Description Date Project Overview The project is a describe the building and its major HVAC systems (e.g. three-story office building, served by a rooftop unit VAV system ). In
More informationThe Heating System and Ventilation and Combustion Air
The Heating System and Ventilation and Combustion Air Introduction Both you and your furnace need some fresh air coming into the house, but most Canadian homes have too much. In fact, 25 percent or more
More informationVentilation. ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce.
Ventilation ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce /NDCommerce /NDCommerce /NDCommerce /NDCommerce WHATS NEW IN ASHRAE 62.2 2016 Controls (Override) Shutoff for maintenance
More informationCHIMNEY INSTALLATION. Technical Bulletin #1
Technical Bulletin #1 CHIMNEY INSTALLATION A chimney performs two functions: it removes smoke and flue gases from the stove/furnace, and it provides draft for the fire. Draft is the term used to describe
More informationHVAC OUTDOOR AIR VENTILATION STANDARD. ASHRAE Standard ASHRAE Standard
ASHRAE Standard 62.1-2013 BuildingsOne February 4, 2016 Landlord s HVAC system design capacity shall equal or exceed outdoor air ventilation requirements specified in ASHRAE Standard 62.1-2013 (prospect
More informationACCA Manual J Load Calculations
ACCA Manual J Load Calculations Understanding what is needed to do a proper load calc Ken Summers Vice President (360) 201-1467 1467 www.comfort-institute.org Comfort Institute Inc. 2004 All Rights Reserved
More informationSupplement A- Improving Forced Air Heating Systems
Supplement A Improving Forced Air Heating Systems The Challenge Recent research and testing of new homes in the Pacific Northwest and across the United States shows the importance of a properly installed
More informationTHE EVALUATION OF MULTI-ZONE AIR FLOW PATTERN AND VENTILATION RATES WITH TRACER GAS METHODS IN APARTMENT HOUSE
THE EVALUATION OF MULTI-ZONE AIR FLOW PATTERN AND VENTILATION RATES WITH TRACER GAS METHODS IN APARTMENT HOUSE DW Yoon 1, JY Sohn 2, SD Kim 3 and HS Kim 4 1 Dept. of Building Equipment and System Engineering,
More information2006 Upgrade Kit FPX Wood Fireplaces
2006 Upgrade Kit Summary The Fireplace Xtrordinair wood fireplaces have been updated in 2006 to improve performance in cold environments when the fireplace is not in use. Gasket for the face and a revised
More information2018 International Energy Conservation Code (IECC) Updates
Providing effective energy strategies for buildings and communities 2018 International Energy Conservation Code (IECC) Updates 04.04.2018 12PM CDT Who we are Our goal: Reduce the energy footprint of Illinois.
More informationThe evil that men do lives after them; the good is oft interred with their bones.
Did I do that?? The evil that men do lives after them; the good is oft interred with their bones. William Shakespeare 1 Windows sweat Mold starts to grow Coil freezes up on A/C Utility bills not as low
More informationMoisture, Ventilation & Global Weirding NEHERS Webinar Series
Moisture, Ventilation & Global Weirding NEHERS Webinar Series Douglas McCleery, PE, CEM July 10, 2017 Discussion Points Weather and Building Practices Constant Change Warm Weather o Temperature o Humidity
More informationOutside Air Requirements... SOLVED!
Outside Air Requirements... SOLVED! Advancing VentilationTM refresh-0918 September 2018 The Whole Building Ventilation Standard With houses and buildings being built as tightly as possible, we are plagued
More information2006 Building Science Press All rights of reproduction in any form reserved.
building science.com 2006 Building Science Press All rights of reproduction in any form reserved. Building Science Digest 110 HVAC in Multifamily Buildings 2006-10-24 by Joseph Lstiburek Abstract: Are
More informationKings County Jail Expansion Phase 3 Rational Analysis of Smoke Control System
Kings County Jail Expansion Phase 3 Rational Analysis of Smoke Control System Kings County Jail Phase 3 Page 2 RATIONAL ANALYSIS OF SMOKE CONTROL SYSTEM PER 2013 CBC 909.4 General Description: The project
More informationUNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1
GENERAL: This section provides general standards for overall sizing and design of Heating, Ventilating, and Air Conditioning (HVAC) systems. Other sections contain specific standards for each system per
More informationSECTION EMERGENCY POWER SYSTEMS
SECTION 16620 EMERGENCY POWER SYSTEMS A. Standby Engine/Generator Systems 1. Installations of stationary engine/generator (e/g) systems shall be designed in strict accordance with ANSI/NFPA 70 - National
More informationNEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet
NEW! Thermo Scientific 1300 Series B2 Class II, Type B2 Biological Safety Cabinet Simplifying Your Safety Decisions Now it s easy to select the best biological safety cabinet for your work with gases and
More informationBOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:
4510 Helgesen Drive, Madison, WI, 53718 608.221.4499, 800.627.4499, Fax: 608.221.2824 support@renewaire.com www.renewaire.com RD2XRT INSTALLATION AND OPERATION MANUAL BOOK 1 OVERVIEW ABOUT BOOK 1: This
More informationResidential New Home Construction Checklist
Residential New Home Construction Checklist A separate permit is required for each address. Address/PID: All materials and the installation of all materials must comply with the Minnesota State Building
More informationComfort and health-indoor air quality
Comfort and health-indoor air quality 1 The human body has a complicated regulating system to maintain the human body temperature constant most of the time, which is 98.6 F (36.9 C) regardless of the environmental
More informationL4064B2210 Fan and Limit Controller with 125 F fan on and 100 F fan off stops, 200 F high limit stop and 11 1/2 in. insertion
HOME ABOUT US PRODUCTS NEWS & EVENTS SUPPORT & RESOURCES CONTACT US HELP VIEW QUOTE Product Search Buildings Homes Applications & Downloads Cross Reference Product Selection Tool Thermostats Whole House
More informationA. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.
SECTION 23 09 93 - SEQUENCE OF OPERATIONS FOR HVAC CONTROLS PART 1 - GENERAL 1 WORK INCLUDES A. Base Bid: Heating Contractor provide: Control sequences for HVAC systems, subsystems, and equipment. B. Alternate
More informationBasic Building Science insights for Spray Foam, HVAC and Moisture
Basic Building Science insights for Spray Foam, HVAC and Moisture Claudette Hanks Reichel, Ed.D. Professor and Extension Housing Specialist Director, LaHouse Resource Center When the blind leads the blind
More informationBOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:
4510 Helgesen Drive, Madison, WI, 53718 608.221.4499, 800.627.4499, Fax: 608.221.2824 support@renewaire.com www.renewaire.com RD2XIN INSTALLATION AND OPERATION MANUAL BOOK 1 OVERVIEW ABOUT BOOK 1: This
More informationabout your house Assessing the Comfort and Safety of Your Home s Mechanical Systems
about your house CE 28 k Assessing the Comfort and Safety of Your Home s Mechanical Systems The heating, ventilating and air conditioning (HVAC) systems are a vital part of every home. These mechanical
More informationDURAVENT POLYPRO VENTING PRODUCTS
DURVENT POLYPRO VENTING PRODUCTS INDEX FLEX VENTING SYSTEM DPTER KIT... 14-11 -VENT RETROFIT DPTERS... 14-10 CHIMNEY CP... 14-10 CHIMNEY LINING KIT... 14-10 CHIMNEY SUPPORT... 14-11 COUPLER DPTER... 14-12
More informationBUILDING VENTILATION GUIDE FOR LG HVAC SYSTEM INSTALLATION
BUILDING VENTILATION GUIDE FOR LG HVAC SYSTEM INSTALLATION PROPRIETARY DATA NOTICE This document, as well as all reports, illustrations, data, information, and other materials are the property of LG Electronics
More informationINSTALLATION OF ACCESS FLOOR SYSTEMS IN GENERAL OFFICE AREA AND COMPUTER ROOM
INFORMATION BULLETIN / PUBLIC - BUILDING CODE REFERENCE NO.: Mech Code 601 Effective: 2-07-79 DOCUMENT NO. P/BC 2002-018 Revised: 9-25-03 Previously Issued As: RGA 2-79, MGD101 INSTALLATION OF ACCESS FLOOR
More informationSequence of Operations (excerpt)
Sequence of Operations (excerpt) Chilled Water System Consists of one (1) 600 cooling ton Trane CVHE 3 stage centrifugal chiller, with associated chilled water pumps, condenser water pumps and one (1)
More informationComplete Ventilation, Heat Recovery and Dehumidification Packaged System by. Maintaining Your Climate for Indoor Pools and Waterparks
Ventilation Heat Recovery PoolPak International Maintaining Your Climate for Indoor Pools and Waterparks Complete Ventilation, Heat Recovery and Dehumidification Packaged System by PoolPak International
More informationDo not use this vent pipe or fittings for venting incinerators of any kind.
! CAUTION! Do not use this vent pipe or fittings for venting incinerators of any kind. C.S.A. Certified For Natural Gas Or Propane Tested For 100 LBS. ASME Working Pressure For correct installation of
More informationA Necessity for Preventing Unsafe Backdrafts and Unhealthy Air
Residential Make-up Air Unit A Necessity for Preventing Unsafe Backdrafts and Unhealthy Air Today s homes are tighter than ever before; as well they should be: Proper sealing yields efficiency and comfort
More informationHVAC Equipment Access Equipment Location
City of Lancaster- Building Department 121 East Chestnut Street, Suite 102, Lancaster, Ohio 43130-3825 (740) 687-6649, Fax (740) 681-5030 Web site: www.ci.lancaster.oh.us/dept/building HVAC Heating, Ventilating,
More informationYOUR SINGLE-SOURCE FOR PROFESSIONAL ENGINEERING SOLUTIONS
YOUR SINGLE-SOURCE FOR PROFESSIONAL ENGINEERING SOLUTIONS Energy International Corporation is the recognized leader in the distribution of HVAC and electromechanical products throughout the Middle East
More informationSHARKBITE CONNECTING SYSTEM
INDEX CASH ACME valves with sharkbite connectors ball valves... 14-8 check valves... 14-8 connectors bullnose... 14-3 reducing... 14-3 straight... 14-3 couplings reducing... 14-2 straight... 14-2 elbows
More informationHeating Maintenance and Repair
Heating Maintenance and Repair Electric Furnace Electric Baseboard Gas Furnace Hydronic Heating Disclaimer The use of photos of tools and/or components which clearly indicate their manufacturer or brand
More informationSolarSheat Solar Heating and Ventilation. Todd Kirkpatrick-President Your Solar Home Inc. Vaughan, Ontario, Canada
SolarSheat Solar Heating and Ventilation Todd Kirkpatrick-President Your Solar Home Inc. Vaughan, Ontario, Canada www.yoursolarhome.com July 13, 2006 Vision Solar heating in every home and building Mission
More information90% Efficiency without Boiler Replacement TRUE GREEN SOLUTIONS NEW. Patent Pending. EcoFlex 90 + System Modulating Fan-Powered Economizer
without Boiler Replacement TRUE GREEN SOLUTIONS NEW Patent Pending EcoFlex + System Modulating Fan-Powered Economizer EcoFlex + System Because They Are Your Btus EcoFlex + System - a packaged modulating
More informationAir Handler Installation Instructions Water Lines
Air Handler Installation Instructions Units must be installed with at least 1 clearance from combustible surfaces. It is recommended that the unit be set on blocks, pads, or legs. Unit should not be sitting
More informationIndoor Air Quality Product Brochure.
Indoor Air Quality Product Brochure Ventilation: A vital system for a healthy home All homes require adequate ventilation for the safety of their occupants and to remove excess humidity, airborne pollutants
More informationCommercial Water Heaters. Genesis. Water Heater Design Guide
Commercial Water Heaters Genesis Water Heater Design Guide Dear Customer, This Genesis Water Heater Design Guide is intended to explain, simplify and help in the planning and the installation of our Genesis
More informationSite address. Ventilation Quantity (Determine quantity by using Table N or Equation 11-1) Continuous ventilation
City of Victoria Building Inspections Department 7951 Rose Street P. O. Box 36 Victoria, MN 55386 (952) 443-4210 Ventilation, Makeup and Combustion Air Calculations Instructions and Example These instructions
More informationIE Code IE Competency Title Credit OAC Ref.
Compulsory Workplace Competency Standards Level Four IE Code IE Competency Title Credit OAC Ref. IE119-4WC Design and draw electrical and electronic drawings including schematics, 4 F5 maintain documentation
More informationTHE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features
THE WALL-MOUNT ONE TON AIR CONDITIONER W2A,800 Btuh 9.00 EER Right Side Control Panel 60Hz GREEN REFRIGERANT R-A The Bard Wall-Mount One Ton Air Conditioner is a self contained energy efficient heating
More informationAppendix A. Glossary of Common Terms
Glossary of Common Terms Glossary of Common Terms Absorption chiller A refrigeration machine using heat as the power input to generate chilled water. Adjustable speed drive A means of changing the speed
More informationResidential 2 Zone Control Panel
Zoning Systems 140202 Residential 2 Zone Control Panel 2 Heat / 1 Cool Compact Housing - 6 x 6 Works with Conventional 4 or 5 Wire Thermostats Works with BlueLink TM Wireless Technology* Installs on Conventional,
More informationVentilation Techniques. Topic 5 - Audio 53
Topic 5 - Audio 53 Increasing Fresh Air Increasing fresh air make-up to a building can dilute radon and other indoor air contaminants. Increasing make-up air can reduce the negative pressures within a
More informationENERGY RECOVERY SOLUTIONS. Recover wasted energy to increase efficiency and save money immediately.
ENERGY RECOVERY SOLUTIONS Recover wasted energy to increase efficiency and save money immediately. Cleaver-Brooks Engineered Boiler Systems Manufacturers of HRSGs, Waste Heat Recovery Units, and Waste
More informationHORIZONTAL FIRE TUBE BOILERS Piping (HVAC) Pumping Equipment (HVAC).
SECTION 15555 HORIZONTAL FIRE TUBE BOILERS PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 15510 - Piping (HVAC). 2. 15540 - Pumping Equipment (HVAC). 1.02 SUBMITTALS A. Submit properly identified
More informationHIGH-EFFICIENCY FURNACES
HIGH-EFFICIENCY FURNACES Built Exclusively for Manufactured Housing Proven components. - reliable Appliance finish. - looks great Fully insulated cabinets. - quiet Miller is a household name. Miller is
More informationBES-TECH TECHNOLOGY & SYSTEM INTEGRATION
BES-TECH TECHNOLOGY & SYSTEM INTEGRATION BES-TECH TECHNOLOGY & SYSTEM INTEGRATION DIGI-ACC Digi-ACC is a control kit for air cooled chiller systems, optimizing both chiller and pumps thereby reducing consumption
More informationModel 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual
Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual FILTER COVER VENTILATION CONTROLLER INLET COLLAR OUTLET COLLAR SAFETY INSTRUCTIONS WARNING 1. 120 Volts may cause serious injury
More informationHIGH EFFICIENCY FURNACES Built Exclusively for Manufactured Housing
HIGH EFFICIENCY FURNACES Built Exclusively for Manufactured Housing Exclusively Made For Your Manufactured Home. Today, the manufactured home is a sophisticated, affordable home that is a smart choice
More information1 Exam Prep Florida Building Code-Mechanical Tabs and Highlights
1 Exam Prep Florida Building Code-Mechanical Tabs and s These 1 Exam Prep Tabs are based on Florida Building Code-Mechanical, 2014. Each 1 Exam Prep tabs sheet has five rows of tabs. Start with the first
More informationIndoor Air Quality Product Brochure.
Indoor Air Quality Product Brochure Ventilation: A vital system for a healthy home All homes require adequate ventilation for the safety of their occupants and to remove excess humidity, airborne pollutants
More informationNRC and Radon Control Technologies
NRC and Radon Control Technologies Prepared by: Dr. Liang Grace Zhou, Gnanamurugan Ganapathy, Gang Nong, Ethan Li, and Jeff Whyte National Research Council Canada - Construction Research Centre For: the
More informationIN065 Rev C Page 1 of 8
IN065 Rev C Page 1 of 8 RadonAway Ward Hill, MA. Series Fan Installation Instructions Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL
More informationHIGH EFFICIENCY FURNACES Built Exclusively for Manufactured Housing
HIGH EFFICIENCY FURNACES Built Exclusively for Manufactured Housing Exclusively Made For Your Manufactured Home. Today, the manufactured home is a sophisticated, affordable home that is a smart choice
More informationInspection Checklist Residential Mechanical Rough In July 2016
Inspection Checklist Residential Mechanical Rough In July 2016 This Inspection Checklist reflects code requirements of the 2015 International Residential Code (IRC), the 2015 Uniform Plumbing Code (UPC),
More informationCity of Chanhassen. Site address. Ventilation Quantity (Determine quantity by using Table R or Equation R )
City of Chanhassen 7700 Market Blvd. - PO box 147 - Chanhassen, MN 55317 Phone 952-227-1180 - Fax 952-227-1190 - Web www.ci.chanhassen.mn.us Ventilation, Makeup and Combustion Air Calculations Instructions
More informationBasic Hood Considerations The design process for a successful kitchen ventilation system starts when the engineering design HVAC team receives
Design Considerations for Commercial Kitchen Ventilation By John A. Clark, P.E., Member ASHRAE Commercial kitchen ventilation (CKV) design must consider everything needed to be coordinated to form a system
More informationINITIAL ELECTRICAL ASSESSMENT REPORT (EAR)
INITIAL ELECTRICAL ASSESSMENT REPORT (EAR) Factory Name: Maks Fashion Ltd 1 Kapashgola Road Chawkbazar Chittagong Chittagong Bangladesh 19 Apr 2014 The Alliance for Bangladesh Worker Safety Page 1/15 19
More informationBOSCH RESIDENTIAL GEOTHERMAL HEAT PUMPS
www.bosch-climate.com INDEX AIR HANDLING UNITS UNITARY DX SERIES... 5-6 HYDRONIC SERIES... 5-6 HEAT PUMPS GEO 1000 WA BP SERIES... 5-4 GEO 3000 WA CE SERIES... 5-5 CP SERIES... 5-4 GEO 6000 WA / WW TA
More informationBOOK 2 SPECIFICATIONS
4510 Helgesen Drive, Madison, WI, 53718 608.221.4499, 800.627.4499, Fax: 608.221.2824 support@renewaire.com www.renewaire.com RD2XIN INSTALLATION AND OPERATION MANUAL BOOK 2 SPECIFICATIONS This book provides
More informationAn Introduction to Energy Efficient and Effective Whole-House Ventilation
0 An Introduction to Energy Efficient and Effective Whole-House Ventilation 1 The 1973 energy crisis caused people to look for ways to reduce the cost of heating and cooling their homes. The building industry
More informationMX 200. MX-200 Technical Specifications FEATURES:
MX-00 Technical Specifications MX 00 TOP VIEW 6.5 Includes: heater,, oil by-pass regulator, pump assembly, primary waste oil strainer, check valve,, oil supply strainer and..5 6.5 6 dia. flue 5.5.5 FEATURES:
More informationSiemens Thermostats. RDY2000BN Thermostat
Siemens Thermostats RDY2000BN Thermostat Answers for infrastructure and cities. Introducing the RDY2000BN BACnet Commercial Thermostat Bring more buildings and zones under control Reduce energy costs BACnet
More informationRHEEM PACKAGE GAS/ELECTRIC
INDEX ACCESSORIES... 4-2 SAMPLE SPECIFICATIONS... 4-2 RKNL (3-5 TON) SERIES... 4-6 RKNL-B (6-12.5 TON) SERIES... 4-7 RKNL-B (15-25 TON) SERIES... 4-8 RKNL-C (6-12.5 TON CLEAR CONTROL ) SERIES... 4-9 RKNL-C
More informationINTELLINOX DEMAND CONTROL KITCHEN VENTILATION
INTELLINOX DEMAND CONTROL KITCHEN VENTILATION COMMERCIAL KITCHEN VENTILATION EXPERTS FOR OVER 25 YEARS WHO WE ARE WE REALLY UNDERSTAND YOUR KITCHEN Extensive knowledge with all kitchen hood manufacturers
More information1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.
2018 NC Energy Conservation Code Commercial Mechanical Module 7 CHAPTER 5 [CE] WORKSHEET 1. When using the COMcheck software, the compliance report submitted by the permit holder shall indicate that the
More informationHEADQUARTERS, DEPARTMENT OF THE ARMY AND THE AIR FORCE 5 AUGUST 1988
ARMY TM 5-4520-256-14 AIR FORCE T.O. 35E7-6-26-1 OPERATOR S, UNIT, INTERMEDIATE DIRECT SUPPORT AND INTERMEDIATE GENERAL SUPPORT MAINTENANCE HEATER, DUCT TYPE, PORTABLE, HDU-36/E, 120,000 BTU, MODEL H82
More informationAddress Account # Member # Equipment Specifications Quantity Rebate. ENERGY STAR Appliances
Rebate not to exceed cost of high efficiency equipment. Equipment must be purchased or recycled in 2015. Installed equipment must be on cooperative's lines. Submit the documentation listed below no later
More informationA whole lot of fresh.
Indoor Air Quality A whole lot of fresh. Trane FreshEffects Energy Recovery Ventilator provides a whole-house solution for fresh air ventilation. Trane FreshEffects exhausts stale indoor air and brings
More informationMechanical Appliance and Equipment Inspection Checklist
34 2015 IRC Performing Residential Mechanical s Mechanical Appliance and Equipment Checklist Inspect Mechanical Appliance and Equipment Comments / I. Identify possible mechanical appliance and equipment
More informationPut the V back in HVAC
Put the V back in HVAC V is for Ventilation A system or means of providing fresh air. Webster New Collegiate Dictionary Benjamin Franklin so unwholesome as air in a closed room that has been often breathed
More informationMakeup Air Systems What goes out, must come in
Makeup Air Systems What goes out, must come in 2 Makeup Air Systems MUAS Makeup Air System Why do we need makeup air? In a nutshell - we would otherwise have problems. Today's homes are built to be more
More informationBOOK 2 SPECIFICATIONS
4510 Helgesen Drive, Madison, WI, 53718 608.221.4499, 800.627.4499, Fax: 608.221.2824 support@renewaire.com www.renewaire.com RD2XRT INSTALLATION AND OPERATION MANUAL BOOK 2 SPECIFICATIONS ABOUT BOOK 2:
More informationDES CHAMPS PRODUCTS 85% 4,400 CFM
DES CHAMPS PRODUCTS Saves up to 85% of the heat from exhaust airstream Removes pollutants before they accumulate Transfers heat energy in winter/cool energy in summer Low cost Capacities up to 4,400 CFM
More informationPRIMEX. Residential Registers, Grilles, and Diffusers. ECCO is proud to be a member of: REV. W-4b
MANUFACTURING EXCELLENCE HVAC Steel Duct Pipe & Fittings PRIMEX Residential Registers, Grilles, and Diffusers ECCO is proud to be a member of: SMACNA Sheet Metal and Air Conditioning Contractors National
More informationEquipment Specifications and Required Information Quantity Rebate
Rebate not to exceed 50% of the cost of equipment. Recycling rebates qualify for the entire rebate, regardless of the recycling cost. Equipment must be purchased or recycled in 2016. Installed equipment
More informationDESIGNER S GUIDE COPPER-FIN
DESIGNER S GUIDE COPPER-FIN BOILER 495,000 2,065,000 Btu/hr Dear Specifier/Project Manager, At Lochinvar, we have long recognized the importance of innovation to any product or service. Those who enter
More informationVCM-X Controller Technical Guide
2 2 www.orioncontrols.com VCM-X Controller Technical Guide VCM-X Controller Code: SS1026 & Y200920 Version 2.0 and up; VCM-X Modular Controller: Tulsa - SS1030; Coil - SS1034 VCM-X WSHP Controller: Tulsa
More informationConsidering Filtration. Austin Baker Ventilation Director Hog Slat, Inc
Considering Filtration Austin Baker Ventilation Director Hog Slat, Inc How will filtration help me? Will do: Provide producers the ability to protect animals from airborne pathogens. Won t do: Make up
More informationabout your house Before You Start an Energy-Efficient Retrofit Mechanical Systems
about your house CE 28i Before You Start an Energy-Efficient Retrofit Mechanical Systems One of the best ways to make your home more comfortable, healthier and less expensive to operate is to upgrade the
More informationHI-VELOCITY SYSTEMS
INDEX ADD-ONS AND ACCESSORIES FILTER RACKS (WITH FILTER)... 2-5 HANGING STRAP KIT... 2-5 HI-VELOCITY AIR PURIFICATION SYSTEM ( PS)... 2-5 RETURN AIR BASE (WITH BUILT-IN FILTER RACK AND FILTER)... 2-5 COILS
More information1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.
SECTION 15855 GAS FURNACE/DX COOLING UNIT PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of contract including General and Supplementary Conditions of Division 1 of Specification
More informationERV3015, ERV3615. Renaissance 30, 36 Wide, High Extension Slim Raised Vents. Top cap with vent down
Document # PG08-004 Revised 02/06/13 Page 1/5 Renaissance 30, 36 Wide, 5/16 (8 mm) thick stiffener across back 3 (7.6 cm) 1 15/16 (4.9 cm) 2 3/16 (5.6 cm) 2 1/8 (5.4 cm) 3/16 (5 mm) 2 9/16 (6.5 cm) Vent
More informationMX 200. MX-200 Technical Specifications FEATURES:
MX-00 Technical Specifications MX 00 TOP VIEW 6.5 Includes: heater,, oil by-pass regulator, pump assembly, primary waste oil strainer, check valve,, oil supply strainer and..5 6.5 6 dia. flue 5.5.5 FEATURES:
More informationIN020 Rev F Page 1 of 8
IN020 Rev F Page 1 of 8 RadonAway Ward Hill, MA. Series Fan Installation Instructions Please Read and Save These Instructions. DO NOT CONNECT POWER SUPPLY UNTIL FAN IS COMPLETELY INSTALLED. MAKE SURE ELECTRICAL
More informationZoning System Design Manual
Zoning Made Effortless 70-2321-03 Introduction The Concept of Zoning The basic principle of forced air zoning is to allow one HVAC system to be controlled by multiple thermostats, heating and cooling a
More informationInstalling an exhaust system with a capacity Wood Heat
HOME COMBUSTION & ENERGY GUIDE TECHNIQUES TACTICS & TIPS Outside combustion air supplies for furnaces, water heaters, wood stoves and fireplaces How to test for combustion air The difference between makeup
More informationHIGH-EFFICIENCY FURNACE INSTALLATION GUIDE FOR EXISTING HOUSES
HIGH-EFFICIENCY FURNACE INSTALLATION GUIDE FOR EXISTING HOUSES Important Considerations for Contractors and Homeowners This Guide was developed to provide contractors and homeowners with general information
More information