MODUCEL KW DOWNFLOW COOLING DRU DRU DATA ROOM UNITS

Size: px
Start display at page:

Download "MODUCEL KW DOWNFLOW COOLING DRU DRU DATA ROOM UNITS"

Transcription

1 MOUEL KW OWNFLOW OOLING RU RU T ROOM UNITS

2 T ROOM UNITS The Moducel range of high efficiency ata Room Units, are designed for high density load areas where a large cooling duty is required from a compact footprint, but without compromising the critical application of data centre cooling. This downflow range of air conditioning units are available in X air cooled, water cooled or chilled water media with optional glycol cooling. ll configurations have energy reduction features as well as heating or humidification options. The RU Range has been designed around a modular frame and panel design providing maximum unit strength as well as all round access where applicable. However, all maintenance and service has been designed for front access only where site restrictions dictate. The units are designed to take return air at a high level which is then filtered and conditioned before being discharged via the base fan section located in the ventilated raised floor. Multiple high efficiency direct drive fans provide even, efficient air supply and inherent redundancy. lternatively, the units can be fitted with speed controllable E fans. ll X units are supplied with twin compressor -stage cooling, whilst chilled water units provide stepless 0 to 100% cooling. Where applicable glycol economy cooling coils can be coupled to dry coolers or economy cooling chillers to maximise efficiency and minimise running costs. Where required, the units can be supplied with electrode boiler humidifiers providing high efficiency stepless output of sterile steam, and electric heaters are available in case of reheat requirement. Features Multiple key components share system loads: Vertical HU frame and panel construction: Modular split fan / coil sections: Underfloor multiple backward curved fans: enefits Increased efficiency and reduced system impact in the unlikely event of a key component failure. ll round access and high unit strength and rigidity. Ease of installation. Efficient air distribution. Model RU8 shown. Hydrophilic coils: Modular component assembly: Fully programmable controller: ustomised control systems: Long life and efficient moisture removal. esigned for easy and quick component maintenance/ replacement. ustomised programming and network capabilities. Ease of integration for existing site upgrades.

3 UNIT FETURES Fan Section.. Electrical Section. 3. ompressor Section. RU

4 TEHNIL SPEIFITION Model RU8 RU10 RU1 X SYSTEM Total ooling kw Gross Sensible ooling kw Net Sensible ooling kw HILLE WTER SYSTEM Total ooling kw Gross Sensible ooling kw Net Sensible ooling kw IR MOVEMENT ir Volume m³/s (m³/h).5 (170) 7.0 (500) 7.0 (500) esign External Pressure rop Pa Number of Fans 3 3 Nominal Power onsumption (per Fan) kw REFRIGERTION Number of ompressors Refrigerant R07c R07c R07c HETING Stages apacity (per Stage) kw HUMIIFITION Humidifier Electrode oiler Electrode oiler Electrode oiler Humidification apacity Kg/hr RU INOOR UNIT imensions (Including Fan ase) Width Height epth mm Filtration EU EU EU Unit Weight** Kg Fan ase Weight Kg INO X ONENSER OUTOOR UNIT ondensers INO - INO - INO 3- imensions Width Height epth mm Weight Kg POWER SPEIFITION FOR LL SYSTEMS Power Supply V/PH/Hz 00/3/50 00/3/50 00/3/50 POWER ONSUMPTION IR OOLE ooling Only Unit (Fans & ompressors) a/phase Temperature Unit (Fans, ompressors & Heaters)* a/phase Full Unit a/phase POWER ONSUMPTION WTER OOLE ooling Only Unit (Fans & ompressors) a/phase 51 8 Temperature Unit (Fans, ompressors & Heaters)* a/phase 51 8 Full Unit a/phase POWER ONSUMPTION HILLE WTER ooling Only Unit (Fans & ompressors) a/phase Temperature Unit (Fans, ompressors & Heaters)* a/phase Full Unit a/phase Notes X Unit cooling duties are based on º / 5% Relative Humidity / 35º mbient. hilled Water (W) Unit cooling duties are based on º / 5% Relative Humidity and º Flow / 11º Return. *No humidity control. **X ir ooled Unit.

5 ONTROLLER The RU is fitted with a fully programmable unitary controller complete with display/user interface. The controller monitors the temperature and relative humidity of the return air and activates cooling humidification or dehumidification to provide precise and efficient conditioning of the supply air. dditionally, the controller monitors the in-built safety devices of the unit which constantly ensure the healthy state of key components. In the unlikely event of a component malfunction the item is automatically isolated to enable the plant to continue running, and an alarm signal will be generated. Where required, multiple units can be networked together to provide group or run/standy control. Units can be monitored locally or remotely, and if required, an enhanced web enabled controller can be supplied, providing password restricted access from a suitable Internet access point. ontrol Features Fully programmable. ata logging. Standalone or group control. MS interface. Remote monitoring. Energy saving control strategies. Monitored Information and larm Points Temperature. Relative humidity. irflow. Filter condition. Refrigerant monitoring. Water detection. Humidifier status. Heater status. Fire shutdown. VF relay alarms. Smoke detection.

6 SYSTEM SELETION ir ooled The air cooled X system circulates refrigerant to absorb heat from the conditioned space at the indoor unit, which is then rejected at the external air cooled condenser. Twin evaporator coil / compressor circuits with multiple supply fans, provide redundancy with four stages of cooling and are coupled to two individual low noise level air cooled condensers, complete with fan speed controls. Optional humidification control can be provided by an electrode boiler humidifier, and optional heaters provide reheat where required during dehumidification mode. Water ooled The water cooled X system circulates refrigerant to absorb heat from the conditioned space at the indoor unit, which is then rejected via an external dry cooler or similar. Twin evaporator coil / compressor circuits with multiple supply fans, provide redundancy with four stages of cooling and are coupled with an individual plate heat exchanger for water cooled heat rejection, complete with three port head pressure control valves. Optional humidification control is provided by an electrode boiler humidifier and optional heaters provide reheat where required during dehumidification mode. Water ooled with Glycol Economy ooling The water cooled X system circulates refrigerant to absorb heat from the conditioned space at the indoor unit, which is then rejected via an external dry cooler or similar. Twin evaporator coil / compressor circuits with multiple supply fans provide redundancy with four stages of cooling and are coupled with an individual plate heat exchanger for water cooled heat rejection, complete with three port head pressure control valves. n additional glycol cooling coil provides low energy cooling when ambient conditions dictate. Optional humidification control is provided by an electrode boiler humidifier and optional heaters provide reheat where required during dehumidification mode. hilled Water The chilled water system circulates water to absorb heat from the conditioned space at the indoor unit which is then rejected at the external chiller. Twin cooling coil with multiple supply fans provide fully modulating 0 to 100% cooling complete with two or three port control valves. Optional humidification control is provided by an electrode boiler humidifier and optional heaters provide reheat where required by the dehumidification mode.

7 SYSTEM ONFIGURTIONS ir ooled Key Internal RU unit Internal fan base section Refrigerant hot gas discharge line Refrigerant liquid line ontroller External air cooled condenser Fan speed controller Water ooled Key 1 Internal RU unit Internal fan base section ry cooler return water ry cooler flow water ontroller External dry cooler Water cooled condenser control valve* * The valves depicted are purely shown schematically and are physically located within the unit.

8 SYSTEM ONFIGURTIONS Water ooled Glycol Economy ooling Key Internal RU unit Internal fan base section ry cooler return water ry cooler flow water ontroller 7 8 External dry cooler Water cool / Glycol cool selection valve* Water cooled condenser control valve* hilled Water Key 1 Internal RU unit Internal fan base section hilled water flow pipework hilled water return pipework hilled water controll valve* ontroller hiller * The valves depicted are purely shown schematically and are physically located within the unit.

9 UNIT IMENSIONS RU8 RU10 310mm 310mm Standard floor level Standard floor level Minimum floor level 780mm 50mm Minimum floor level 780mm 50mm 1700mm 0mm RU1 310mm Standard floor level Minimum floor level 780mm 50mm 0mm Note: ll RU units are 1090mm deep.

10 INO X IR OOLE ONENSER 07mm Twin Fan Unit 3507mm Triple Fan Unit 1100mm 1100mm Horizontal Mount (Vertical ir Flow) Elevation 1000mm 50mm 105.5mm Vertical Mount (Horizontal ir Flow) Elevation 1000mm

11 GROUP PROUTS & SERVIES Server abinets & Rear oor Heat Exchangers (RHx) Powerful cooling capacity, up to 30kW heat removed at source and rejected to water, not the room. ondense free operation using dew point controlled water from the U. hot swap fans variable speed. 80% front door venting. 1,000kg weight loading and full range of accessories. Easily installed via leak free quick release ¾" couplings and hose sets. 00mm wide 0kW cooling. 800mm wide 30kW cooling. U (ooling istribution Unit) Provides cooling water for up to rear door heat exchangers. ooling capacities of 100, 10 or 150kW with full run/standby capability (N+1). Internal manifold with leak free quick release couplings for easy installation and connection to the rear door heat exchangers via ¾" hose sets. hilled water connections (mm / 1½") via top or bottom. ew point temperature control of cooling water, internal W filtration. uto fill and bleed of coolant. Full alarm monitoring and connectivity. U Module The 0kW U Module is a u rack mountable, self contained cooling module capable of providing closely controlled cooling water above dew point to one or two rear door heat exchangers. Leak free, quick release couplings enable rapid install and connection to the rear door heat exchanger via ¾" hose sets. Features include dew point temperature control for condense free operation, uto fill and bleed of coolant, full alarm monitoring and connectivity. Modular U System dedicated cabinet to house up to U Modules to enable initial install to be completed allowing the perfect upgrade path. The cabinet houses power distribution and chilled water connectivity to the U Modules via manifold and couplings. Individual U Modules can then be simply plugged in as the data centre expands or heat loads increase. larms, room temperature and humidity data are managed through the central power distribution system giving one connection point for power and alarms. RU (R) Unit RU ata Room air conditioning units are designed for high density load areas where a large cooling duty is required, from a compact footprint, but without compromising the critical application of data centre cooling. 80/100/10kW cooling capacities. vailable in chilled water, X, X with water cooled condenser and glycol free cooling configurations. full range of options and ancillaries are available including inbuilt humidifier for room humidity control. IP (R) Unit IP floor standing air conditioning units are available in chilled water or X, cooling only configuration kW cooling capacities available in various configurations including up flow or down flow air path, chilled water or X cooling. full range of options and ancillaries are available including inbuilt humidifier for room humidity control. hillers Energy efficient chillers up to a capacity of 00kW with the full run/standby (N+1) capability can be offered. These can also be fitted with free cooling capability and qualify for E (Enhanced apital llowance) under the arbon Trust Scheme. Grilles & iffusers Our extensive range of grilles and diffusers are available in a wide range of shapes and sizes and include floor grilles for server/data centres. Service & Maintenance ll types of HV heating, ventilating and air conditioning equipment are supported by our national network of mobile engineers or residential engineers for optimum operating efficiency. M&E Services Project design, installation and commissioning. Refurbishment. F and HF recovery and substitution. Humidification Specialist manufacturers of humidifiers and steam generation products. ir Handling Eaton-Williams design and manufacture air handling plant for commercial and industrial applications. pplications include hospitals, supermarket chains, leisure stadiums, pharmaceutical buildings and office complexes with uniquely designed solutions to suit each project.

12 PROUT RNGES omputer Room & ata entre ooling ir-cooled & Water-cooled Liquid hillers Packaged Roof-Top Units Full Range of ir Handling Units Fan oil Units Packaged Telecommunications Units Fresh ir Units ondensing Units ir ooled ondensers Low Temperature assettes ellar & Storage Low Temperature ooling Units Packaged In-Wall Units Stand-alone Humidifiers OEM Process ooling ontrol Units ustom esigned Packages onstant & Variable ir Volume Units U HI UI JFZ MUST OH 3 UE OMN QTR

IPAC. Invicta Precision Air Control Floor Standing Range

IPAC. Invicta Precision Air Control Floor Standing Range IPC Invicta Precision ir Control Floor Standing Range The Invicta Precison ir Control (IPC) range of floor standing units has been developed to satisfy the exacting standards for full function air conditioned

More information

CHILLED WATER DATA ROOM UNITS

CHILLED WATER DATA ROOM UNITS Critical Infrastructure for the World s Leading Data Centers CHILLED WATER DATA ROOM UNITS Downflow Net Sensible Cooling 79 220kW Upflow Net Sensible Cooling 66 206kW DATA CENTER COOLING EXPERTISE Data

More information

8-101kW. AlphaCool close control range ADDITIONAL CAPACITIES. NOW AVAILABLE Plus EC fan option kW. Typical applications

8-101kW. AlphaCool close control range ADDITIONAL CAPACITIES. NOW AVAILABLE Plus EC fan option kW.  Typical applications AlphaCool close control range 8-101kW - 101kW > Typical applications > Data Centres > Telecommunications and ISP facilities > Computer rooms > Clean rooms > Switching stations > Laboratories www.airedale.com

More information

Flexible & Innovative. Cooling Solutions

Flexible & Innovative. Cooling Solutions Flexible & Innovative Cooling Solutions Flexible & Innovative Compu-Aire Inc. offers a variety of high performance precision cooling systems that can adapt to your application needs. With today s rapidly

More information

gforce Units Data Aire and Data Temp Series

gforce Units Data Aire and Data Temp Series gforce Units gforce gforce is the most advanced mission critical cooling equipment available on the market today. These units are the most efficient and economical while complying with strict environmental

More information

Outstanding Performance; Application Flexibility

Outstanding Performance; Application Flexibility PORTLE HILLER4EP2 SERIES Outstanding Performance; pplication Flexibility EP2 Series Portable hillers are designed for 4 to 43 ton applications. Units are available in air-cooled, water-cooled and remote

More information

Appendix 13. Categories of Cooling and Heating systems

Appendix 13. Categories of Cooling and Heating systems EcoShopping - Energy efficient & Cost competitive retrofitting solutions for Shopping buildings Co-funded by the European Commission within the 7 th Framework Programme. Grant Agreement no: 609180. 2013-09-01

More information

PURIFICATION SOLUTIONS. R-Series 1. cycling refrigeration compressed air dryers flow capacity: scfm ( Nm 3 /hr)

PURIFICATION SOLUTIONS. R-Series 1. cycling refrigeration compressed air dryers flow capacity: scfm ( Nm 3 /hr) PURIFITION SOLUTIONS R-Series R cycling refrigeration compressed air dryers flow capacity: 20-2000 scfm (34-3400 Nm 3 /hr) R-Series cycling refrigeration compressed air dryers flow capacity: 20-2000 scfm

More information

RHC GAS FIRED HEATING COILS

RHC GAS FIRED HEATING COILS CI/SfB 56.83 X RHC GS FIRED HETING COILS RHC GS FIRED REZNOR HETING COILS Introduction Reznor gas fired heating coils are designed for inclusion in air handling units to provide a high efficiency gas fired

More information

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump

Pathfinder Air-Cooled Single-Screw Chiller/Heat Pump Engineered for flexibility and performance. TM MHS-R134a-2012 Pathfinder ir-ooled Single-Screw hiller/heat Pump Super-high-efficiency series : MHS105-MHS348 ooling capacity: 393 kw 1334 kw Heating capacity:

More information

STULZ Compact CWE. Engineering Manual. Computer Room Air Handlers kw Precision Air Handlers Utilizing EC Fan Technology (60 Hz Data)

STULZ Compact CWE. Engineering Manual. Computer Room Air Handlers kw Precision Air Handlers Utilizing EC Fan Technology (60 Hz Data) Indoor Cooling Perimeter STULZ Compact CWE Computer Room ir Handlers 30-360 kw Precision ir Handlers Utilizing EC Fan Technology (60 Hz Data) EM Engineering Manual 1 STULZ Our Mission Our mission is to

More information

Printed 2000, replaces all previous editions PAK.5231 PAK.5232 COOLING UNITS FOR CLIMATE CONTROL, COMMERCIAL REFRIGERATION AND INDUSTRIAL APPLICATIONS

Printed 2000, replaces all previous editions PAK.5231 PAK.5232 COOLING UNITS FOR CLIMATE CONTROL, COMMERCIAL REFRIGERATION AND INDUSTRIAL APPLICATIONS Printed 2000, replaces all previous editions Kyl M (98) PK.523 PK.5231 PK.5232 OOLIN UNITS OR LIMT ONTROL, OMMRIL RRIRTION N INUSTRIL PPLITIONS Swedish cooling units. Mini, Mid The rigadon range of commercial

More information

Multi-Denco. » Precision Climate Control. Air Conditioning & Heating. Multi-DENCO

Multi-Denco. » Precision Climate Control. Air Conditioning & Heating. Multi-DENCO Air Conditioning & Heating Multi-DENCO Multi-Denco» Precision Climate Control Promise Precision control is more than just an industry term, it is a promise. A promise we sustain using our extensive experience.

More information

60 Hz. Catalogue_2016 REFRIGERATION UNITS. - Commercial Range -

60 Hz. Catalogue_2016 REFRIGERATION UNITS. - Commercial Range - 60 Hz atalogue_2016 - ommercial Range - RERIGERTION UNITS ommercial monoblocks Tropicalized design for high ambient temperature up to 45º Thermostatic expansion valve Hot gas defrosting Refrigerant load

More information

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance

Control Systems. Design & Manufacturing. Eco-Friendly. High Performance Temperature & Humidity Control Systems Design & Manufacturing DX Air / Water / Glycol Cooled Air and Water Side Economizer Chilled Water Systems Eco-Friendly High Performance OPTIMAL COOLING SOLUTIONS

More information

Air Cooled Scroll Chiller

Air Cooled Scroll Chiller ir ooled Scroll hiller Midea chillers use V shape heat exchanger and single unit s capacity from 30kW to 250kW.They are divided to PS, PS-L,PS-HM and PS-HML series according to their operation ambient

More information

IPAC Air Handling Units

IPAC Air Handling Units Eaton-Williams IPAC IPAC Air Handling Units Short-form version - extracted from Section 2 of the Installation, Operation and Maintenance Manual Technical Product Guide IPAC (Invicta Precision Air Control)

More information

PRODUCTS. Configurable Packaged Air Handling Equipment VRC SERIES

PRODUCTS. Configurable Packaged Air Handling Equipment VRC SERIES PROUTS onfigurable Packaged ir Handling quipment VPR SRIS VPRX SRIS VPR SRIS VPRP SRIS VPR SRIS VR SRIS TH VLNT VNTG Quality, reliability, flexibility, and support Valent manufactures highly configurable

More information

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center

> Refrigerant R-410A. Uniflair LE TDER-TUER kW. Energy-saving units with backward-curved fans. Perimeter cooling for medium/large data center Uniflair LE TDER-TUER Energy-saving units with backward-curved fans 20-100kW > Perimeter cooling for medium/large data center > Refrigerant R-410A Available Versions: > Downflow (TDER) > Upflow (TUER)

More information

Chilled Water Precision Air Conditioner for Critical Application

Chilled Water Precision Air Conditioner for Critical Application AIRSYS-P-SC-OPTIMA-HD-E14507V01.3 HD Chilled Water Precision Air Conditioner for Critical Application Cooling Capacity: 42.1kW~180.9kW OPTIMA product family is designed for medium to large data center.

More information

SysTemp NEW. Close Control Engineering Data Manual

SysTemp NEW. Close Control Engineering Data Manual Fans ir Handling Units ir istribution Products ir onditioning Fire Safety ir urtains and Heating Products Tunnel Fans SysTemp NEW Series Series Series Series lose ontrol Engineering ata Manual 2 Key points

More information

Design, Construct, and Operate to Control Indoor Humidity

Design, Construct, and Operate to Control Indoor Humidity EHUMIIFITION: Natatorium pplication & Product Guide esign, onstruct, and Operate to ontrol Indoor Humidity The Humidity Expert Munters is the world leader in dehumidification Munters is the largest manufacturer

More information

Close Control Air Cooled Twin Circuit Range

Close Control Air Cooled Twin Circuit Range Close Control Air Cooled Twin Circuit Range Engineering Data Manual 50/60Hz ENGINEERING DATA MANUAL 50/60Hz Index Description Page YORK Company Profile 3 This Product Range 3 Other YORK Close Control Product

More information

SmartCool i-drive Inverter Compressor. 5-83kW Up to 45% more cooling kw/m 2 * + + Up to 21% more cooling kw/m 2 **

SmartCool i-drive Inverter Compressor. 5-83kW Up to 45% more cooling kw/m 2 * + + Up to 21% more cooling kw/m 2 ** Precision Air Conditioning DX SmartCool i-drive Inverter Compressor 5-83kW + + Up to 45% more cooling kw/m 2 * + + Up to 21% more cooling kw/m 2 ** * compared to fixed speed compressor systems ** compared

More information

Mission Critical Air Conditioning Systems

Mission Critical Air Conditioning Systems Mission Critical Air Conditioning Systems wall & ceiling mount Series 7 & 11 1-5 Ton Units Single Circuit Units Designed for Superior Space Utilization Series 7 1.5-2.5 tons Compact wall mounted split

More information

IDU22C, 22C1, 37C, 37C1, 55C, 75C

IDU22C, 22C1, 37C, 37C1, 55C, 75C Refrigerated ir ryer Series IU edium IU, 1, 7, 71, 55, 75 () () () () () Run light Operation (ftercooler) Stop (ftercooler) Outlet air pressure gauge vaporation () (I) () Terminal block () () P rain port

More information

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University AIR-CONDITIONING SYSTEMS AND APPLICATIONS Abdullah Nuhait Ph D. King Saud University AIR-CONDITIONING SYSTEMS Earliest air conditioning system used only for heating (winter) Provided heated air for comfort

More information

2013 Product Range Precision Air Conditioners (CRAC)

2013 Product Range Precision Air Conditioners (CRAC) 2013 Product Range Precision Air Conditioners (CRAC) 2013 Product Range RC Group air conditioners range CLOSE CONTROL AIR CONDITIONERS 2,0-244,0kW HEAT PUMP AIR CONDITIONERS 6,3-113,0kW 6,3-101,0kW AIR

More information

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units

Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units Climate control precision in Hi-tech environments Jupiter and Mercury Close Control Units Precision control from the total provide Uncompromised precision More than ever data centers, server rooms, and

More information

next evo cw next evo cw rcgroupairconditioning

next evo cw next evo cw rcgroupairconditioning : Close control air conditioners for chilled water feeding with upflow or downflow air delivery Cooling Capacity: 6,2 248,0 rcgroupairconditioning E C CHILLED WTER UP FLOW DOWN FLOW MIN FETURES Chilled

More information

SmartCool i-drive Inverter Compressor. 5-83kW Up to 45% more cooling kw/m 2 * + + Up to 21% more cooling kw/m 2 **

SmartCool i-drive Inverter Compressor. 5-83kW Up to 45% more cooling kw/m 2 * + + Up to 21% more cooling kw/m 2 ** Precision Air Conditioning DX SmartCool i-drive Inverter Compressor 5-83kW + + Up to 45% more cooling kw/m 2 * + + Up to 21% more cooling kw/m 2 ** * compared to fixed speed compressor systems ** compared

More information

KOMPAKT. Air Handling Units

KOMPAKT. Air Handling Units ir Handling Units KOMPKT escription of Komfovent kompakt units 2 The new development in KOMPKT REGO range 3 Reasons to choose Komfovent kompakt units 4 ontrol System 6 KOMFOVENT KOMPKT REGO 10 Rotary

More information

COTES ALL-ROUND THE C35 RANGE

COTES ALL-ROUND THE C35 RANGE EPERTS IN HUMIITY MNGEMENT OTES.OM IEL FOR USE IN 3 Pharmaceutical production facilities Food industry processing facilities old stores/freezer facilities Waterworks General humidity management in all

More information

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW

AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW. Row Cooling Precision Air Conditioner. Cooling Capacity: 26.2kW~68.6kW AIRSYS-P-SC-CHILLROW-E1503V01.1 CHILLROW Row Cooling Precision Air Conditioner Cooling Capacity: 26.2kW~68.6kW CHILLROW is installed closely with the server cabinets and refrigerating independently. The

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir ryers /IU Series Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic

More information

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel

Daikin Applied UK Technically better... D-AHU Modular R. Air handling units. Compact air handling unit with heat recovery wheel Daikin Applied UK Technically better... D-AHU Modular R Air handling units Compact air handling unit with heat recovery wheel Energy efficiency and air quality With their Plug & Play design and inherent

More information

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline ME 414/514 HVAC Systems Overview Equipment Outline 2-1 The Complete System 2-2 The Air-Conditioning and Distribution System 2-3 Mechanical Equipment Air-handling Equipment Heating Equipment Boilers Furnaces

More information

Patent Pending CO 2 OLrac. Blade Server Cooling

Patent Pending CO 2 OLrac. Blade Server Cooling Patent Pending 0421232.0 CO 2 OLrac Blade Server Cooling Cooling with CO 2 Carbon dioxide (CO 2 ) is an ideal refrigerant, particularly when considered against ecological and safety criteria. It is natural,

More information

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning : Packaged air cooled liquid chillers with free-cooling system for outdoor installation, equipped with screw compressors and axial fans Cooling Capacity: 314 1343 Free-Cooling Capacity: 308 938 GLYCOL

More information

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features: Heat Pumps SA SERIES Features: Vertical self-contained units with capacities from 23 70 tons Direct drive backward curved plenum and reduced maintenance Double wall rigid polyurethane foam injected panel

More information

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V

120D, 150D, 190D, 240D, 370B. How to Order 220V 240V 400V 440V. Note 1) Select one applicable voltage. Voltage. Voltage. Symbol. Model 370B 220V 240V Refrigerant R7 0, 0 90 I ir compressor Refrigerant 0kW kw 90kW kw Refrigerant R 70 I Refrigerant R7, R Series I Large 0,, 90,, 70 0 90 R7 Size 70 7 9 0 90 Three Voltage 7 9 Voltage 00/00 to 0V (/Hz) 0V

More information

ABBE LEVEL 4 DIPLOMA IN AIR CONDITIONING ENERGY ASSESSMENT ABBE LEVEL 4 DIPLOMA IN AIR CONDITIONING ENERGY ASSESSMENT (QCF)

ABBE LEVEL 4 DIPLOMA IN AIR CONDITIONING ENERGY ASSESSMENT ABBE LEVEL 4 DIPLOMA IN AIR CONDITIONING ENERGY ASSESSMENT (QCF) E LEVEL 4 IPLOM IN IR ONITIONING ENERGY SSESSMENT E LEVEL 4 IPLOM IN IR ONITIONING ENERGY SSESSMENT (QF) SMPLE EXMINTION QUESTIONS The purpose of this document is to provide examples of typical questions

More information

Dry desiccant dehumidification systems. Product guide

Dry desiccant dehumidification systems. Product guide Dry desiccant dehumidification systems Product guide dvanced dehumidification Leading dry desiccant technology enefits of dry technology: Dehumidification independent of cooling est suited for warm, dry

More information

EC MODEL. EC Model & Split Systems Water Source Heat Pump. 6 to 30 tons

EC MODEL. EC Model & Split Systems Water Source Heat Pump. 6 to 30 tons E & Split Systems Water Source Heat Pump 6 to 30 tons The E, including Split Systems, provides the best combination of performance, comfort and one-of-a-kind features that satisfy the high demands of any

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir ryers Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment

More information

Denco has been producing and installing. equipment specifically designed for the precise. control of air temperature, humidity and quality

Denco has been producing and installing. equipment specifically designed for the precise. control of air temperature, humidity and quality Denco has been producing and installing equipment specifically designed for the precise control of air temperature, humidity and quality for 60 years. Today, clean rooms, telecommunications centres and

More information

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems Mission Critical Air Conditioning Systems vertical floor mount Series 6, 8 & 9 2-30 Ton Units Single Circuit for Superior Economy and Dual Circuit for Ultimate Protection Series 6 2-5 tons Compact Footprint

More information

Computer Room Air-Conditioning 60 Hz. Technical Data

Computer Room Air-Conditioning 60 Hz. Technical Data TM Computer Room Air-Conditioning 60 Hz 35 150 kw (10 45 tons) Technical Data Contents Overview.............................................................. 1 Scalable Solution for Critical Environments.................................

More information

InRow Direct Expansion

InRow Direct Expansion InRow Direct Expansion Close-coupled, air, water, and glycol cooling for closets, server rooms, and data centers Up to kw > Row-Based Cooling InRow SC, 00mm InRow RD, 00mm The InRow Direct Expansion product

More information

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified Data Aire LCS TM (Large Ceiling System) 6, 8, 10, and 13 ton ISO 9001 Certified LCS TM (LARGE CEILING SYSTEMS) DX Product Description Performance and Electrical Data 3 the pioneer and builder of the most

More information

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors

WZT High Efficiency Air to Water Split System Heat Pumps With E.V.I. Compressors High Efficiency ir to Water Split System Heat Pumps With E.V.I. ompressors -20 +43 +65 HP E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor

More information

Heat pump and energy recovery systems

Heat pump and energy recovery systems SBS5311 HVACR II http://ibse.hk/sbs5311/ Heat pump and energy recovery systems Ir. Dr. Sam C. M. Hui Faculty of Science and Technology E-mail: cmhui@vtc.edu.hk Oct 2017 Contents Basic concepts Air-to-air

More information

SPLIT System. SPLIT System Simple and flexible direct expansion solutions for the commercial sector and industry

SPLIT System. SPLIT System Simple and flexible direct expansion solutions for the commercial sector and industry System System Simple and flexible direct expansion solutions for the commercial sector and industry System is the autonomous solution for climate control in small and medium shops. The cooling or thermal

More information

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion

GEA Ultra-Denco. GEA Heat Exchangers / HVAC Systems. Close Climate Control for IT Environments. Reliability with low power consumpstion Close Climate Control for IT Environments GEA Ultra-Denco Reliability with low power consumpstion GEA Heat Exchangers / HVAC Systems Numerical Flow simulation Velocity / Pressure field / Turbulence high

More information

BENSON.... Variante3 Fired Unit Heaters...

BENSON.... Variante3 Fired Unit Heaters... NSON Variante3 as ired Unit Heaters 3 Variante... as ired Unit Heaters... The new Variante3 builds on the technical excellence of the previous range to provide cost effective and robust heating for industrial

More information

COTES ALL-ROUND THE C35 RANGE

COTES ALL-ROUND THE C35 RANGE EPERTS IN HUMIITY MNGEMENT OTES.OM EHUMIIFITION THE WY YOU WNT IT 35 EHUMIIFIER (MOEL SHOWN WITH PL) IEL FOR USE IN > PHRMEUTIL PROUTION FILITIES > FOO INUSTRY PROESSING FILITIES > OL STORES/FREEZER FILITIES

More information

F Series - Refrigeration dryers

F Series - Refrigeration dryers F Series - Refrigeration dryers Quality compressed Air Flows from 0,38 to 110 m 3 /min QUALITY, DRY COMPRESSED AIR: THE EFFECTS: Considerably reduced production costs. Circuit protected against corrosion.

More information

DESCRIPTION APPLICATIONS MD800S SUPPLY MODULE

DESCRIPTION APPLICATIONS MD800S SUPPLY MODULE POSSIBLE CONFIGURATIONS MEDICAL AND HEALTHCARE RANGE Supply Air Only - and -Twin MD800 RANGE Fully packaged environmental control system, specifically designed for medical and healthcare applications DESCRIPTION

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated ir ryer E/F Series For use in Europe, sia and Oceania Standard/ E Series H HW Power supply voltage: Single-phase 230 V (50Hz) 3E 4E 6E 8E 11E 15E1 22E 37E 55E 75E ir flow capacity (m3/h [NR])

More information

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features: Heat Pumps SA SERIES SA Series Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features: Vertical self-contained units with capacities from 23 70 tons Direct drive backward curved plenum

More information

pyxis pyxisa NEW rcgroupairconditioning

pyxis pyxisa NEW rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 119,0 808,0 PLTE C rcgroupairconditioning

More information

Series 8. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Series 8. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc. MISSION CRITICAL Air Conditioning Systems Series 8 Guide Specification 60 Hz S8-GS-602017.doc 2014 ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 Series 8 Guide Specification-60

More information

Flexible and efficient: Close Climate Control for IT equipment

Flexible and efficient: Close Climate Control for IT equipment GEA Multi-DENCO Flexible and efficient: Close Climate Control for IT equipment engineering for a better world GEA Heat Exchangers GEA Multi-Denco at a glance: Multiple functions and applications High flexibility

More information

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS. RN/RQ Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS RQ Series Features: Air-cooled or water-cooled condenser, with unit capacities

More information

Rotary Screw Compressors BSD/CSD/CSDX T SFC Series

Rotary Screw Compressors BSD/CSD/CSDX T SFC Series Rotary Screw ompressors SD/SD/SDX T SF Series With the world-renowned SIGM PROFILE ir deliveries from 0.87 to 5.85 m /min, Pressures 5.5 to 5 What do you look for in a compressor with variable frequency

More information

30RB /30RQ

30RB /30RQ AIR-OOLE LIQUI HILLER REVERSIBLE AIR-TO-WATER HEAT PUMP PRO-IALOG PLUS * Unit with low noise option 30RB9-80/30RQ0-46 Refrigerant HF-40A Nominal cooling capacity 93-78 kw Nominal heating capacity 7-0 kw

More information

Series PS6, Vertical Floor-Mount Units

Series PS6, Vertical Floor-Mount Units Series PS6, Vertical Floor-Mount Units Technical Data 60 Hz sps6em6ea.doc Dec-12 ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 Table of Contents Table of Contents...

More information

New standard in compressed air treatment, providing Energy Savings up to 99%

New standard in compressed air treatment, providing Energy Savings up to 99% PCM Series Specification for APAC Model Flow Capacity (Nm 3 /min) Pressure Dew Point ( ) Power Consumption (kw) Power Supply (V/Ph/Hz) Inlet/Outlet Connections Weight (kg) Dimensions (H x W x D mm) Refrigerants

More information

Personalized comfort for offices and shopping malls RANGE OPERATING LIMITS

Personalized comfort for offices and shopping malls RANGE OPERATING LIMITS R-c Personalized comfort for offices and shopping malls iscreet solution in centralized facilities with closed water loop asy installation in false ceiling T-XH-5-I-I SRIPTION Heat Pumps and ooling Units

More information

OLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER

OLIMPIA SPLENDID S INVERTER DC TECHNOLOGY 100% 80% 70% DC INVERTER AC INVERTER NON INVERTER SHERP ir-water heat pump COP > 4 DHW 60 C Energy class ErP (1) : RENEWLE TECHNOLOGIES Sherpa uses the heat in the air, and transfers it to system terminals in an efficient manner. For each kw of electricity

More information

Refrigerated Air Dryer

Refrigerated Air Dryer Refrigerated ir ryer Series For use in North, entral & South merica Protect Pneumatic quipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and

More information

DOMEKT. Residential ventilation units

DOMEKT. Residential ventilation units OMEKT Residential ventilation units OMEKT Komfovent OMEKT OMEKT air handling units (HU) are designed for the ventilation of residential premises. OMEKT is a standardized series of the air handling units

More information

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning Industrial PYXIS CL: Packaged air cooled liquid chillers in class energy efficiency for outdoor installation, equipped with scroll compressor and microchannel condensing coils Cooling Capacity: 108 876

More information

within a Quality Management System ISO9001 and Environmental Management System ISO Sales Offices CERTIFICATION

within a Quality Management System ISO9001 and Environmental Management System ISO Sales Offices CERTIFICATION THE COMPANY CITEC INTERNATIONAL was established in year 1996. As one of the leaders in designing and manufacturing Precision Air Conditioning system, CITEC always places great emphasis on achieving the

More information

CONDAIR EL. Electrode boiler steam humidifier Easy maintenance with replaceable cylinders. Humidification and Evaporative Cooling

CONDAIR EL. Electrode boiler steam humidifier Easy maintenance with replaceable cylinders. Humidification and Evaporative Cooling CONDAIR EL Electrode boiler steam humidifier Easy maintenance with replaceable cylinders Humidification and Evaporative Cooling Replaceable boiling cylinders make servicing simple Intelligent design for

More information

Condensing units with inbuilt control board, to be connected to refrigerated cabinets and special evaporating units...

Condensing units with inbuilt control board, to be connected to refrigerated cabinets and special evaporating units... condensing units MDH / DH, MDF / DF series ondensing units ondensing units with inbuilt control board, to be connected to refrigerated cabinets and special evaporating units... intarbox entrifugal condensing

More information

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools

Heat Recovery Dehumidification (HRD) system. Designed for municipal swimming pools Heat Recovery Dehumidification (HRD) system Designed for municipal swimming pools A dehumidification and ventilation system with dynamic heat pump heat recovery to swimming pool water and air ENVIRONMENTAL

More information

PYXIS U PYXIS U. rcgroupairconditioning

PYXIS U PYXIS U. rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44 284 rcgroupairconditioning MIN FETURES

More information

Air-Handling System Cooling Options

Air-Handling System Cooling Options Air-Handling System Cooling Options High-Capacity, Economical Evaporative Cooling High-Efficiency, DX & CW Mechanical Cooling Pure and Simple Solutions AbsolutAire Air-Handling System Cooling Options Economical

More information

MECHANICAL SERVICES 101. Ian White

MECHANICAL SERVICES 101. Ian White MECHANICAL SERVICES 101 Ian White Contents 1. Ventilation 2. Heat Gains & Losses 3. Heating Ventilation Air Conditioning (HVAC) Systems What are Building Services Building Services incorporate all aspects

More information

Refrigerated Air Dryer

Refrigerated Air Dryer T.S30-8 Refrigerated ir ryer Series IF/IU ir flow capacity Power consumption Refrigerant Increased up to the max. 40% ecreased up to the max. 40% F34a oefficient of destruction for ozone is zero. Improved

More information

RIGID DC LIQUID CHILLER

RIGID DC LIQUID CHILLER RIGID DC LIQUID CHILLER Phone: +86-579-8837-9768 Email:info@rigidhvac.com Website: www.rigidchill.com 1 1. WHAT S LIQUID CHILLER? Liquid Chiller cooling refers to cooling by means of the convection or

More information

pyxis u pyxis ua NEW rcgroupairconditioning

pyxis u pyxis ua NEW rcgroupairconditioning Industrial : Packaged air cooled liquid chillers for outdoor installation equipped with scroll compressors and microchannel condensing coils Cooling capacity: 44,9 200,0 rcgroupairconditioning R410 C PLTE

More information

Precision air handling cabinets Ciatronic MICRO/EXPAIR

Precision air handling cabinets Ciatronic MICRO/EXPAIR / Reducted footprint Double-wall construction Built-in voltage variator PLC control Variable speed condenser fan ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY L'ENVIRONNEMENT Cooling capacity: 5 to

More information

Aegean Range. A new range of fan coils for heating and cooling commercial applications

Aegean Range. A new range of fan coils for heating and cooling commercial applications egean Range new range of fan coils for heating and cooling commercial applications How Fan Coils work Fan Coils provide heating and cooling solutions for a wide range of applications. Fan Coil Unit (FCU)

More information

Precision Air-Conditioning Units 60 Hz. Technical Data

Precision Air-Conditioning Units 60 Hz. Technical Data â NetworkAIR TM CM Series Precision Air-Conditioning Units 60 Hz Technical Data Contents Available Models................................. 1 Spot-cooled 1 Ducted 1 System Configurations.............................

More information

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES

LZT LZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSION ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors -15 +63 E.V.I..O.P. 4,1 The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners

STULZ CyberAiR Floor Mounted Systems. Engineering Manual. Floor Mounted Air Conditioners Floor Mounted Air Conditioners Indoor Cooling Perimeter STULZ CyberAiR Floor Mounted Systems 60-730 kw Chilled Water Systems Precision Air Handlers Utilizing EC Fan Technology (60Hz Data) EM Engineering

More information

Series 6. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc.

Series 6. Guide Specification 60 Hz. MISSION CRITICAL Air Conditioning Systems. ClimateWorx International Inc. MISSION CRITICAL Air Conditioning Systems Series 6 Guide Specification 60 Hz S6-GS-602017.doc ClimateWorx International Inc. 14 Chelsea Lane, Brampton, Ontario, Canada L6T 3Y4 Series 6 Guide Specification-60

More information

Industrial cooling solutions

Industrial cooling solutions Industrial cooling solutions Protect the Environment and your Investments The use of chilled water is essential in many industrial production and transformation processes. The range of needs varies from

More information

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning HVAC 101 The Basics of Heating, Ventilation and Air Conditioning HVAC Heating, Ventilation and Air Conditioning Provides comfort for people Allows humans to exist under adverse conditions. Comfort Comfort

More information

LZT LZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. A + A + VERSIONS ACCESSORIES

LZT LZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. A + A + VERSIONS ACCESSORIES High efficiency air to water heat pumps with E.V.I. compressors + + -0 +43 +65 E.V.I. The series of high efficiency heat pumps has been specifically designed for use with radiant floor heating systems

More information

DRYMODULE HEAT EXCHANGER

DRYMODULE HEAT EXCHANGER ooling, conditioning, purifying. DRYMODULE HET EXHNGER 3-in-1 configuration: The precooler-reheater, evaporator and demister are housed in a single aluminium module. This ensures a very compact, robust

More information

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features: Heat Pumps SB SERIES Features: Vertical self-contained units with capacities from 3-18 tons ECM driven direct drive backward curved plenum supply fans for improved energy Double wall rigid polyurethane

More information

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz EN Technical Catalogue Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: 321-1308 kw 50 Hz EKV/BS business Air cooled water chillers for outdoor installation. Flexibility in the

More information

IT COOLING CLOSE CONTROL AIR CONDITIONERS PRECISION AIR CONDITIONERS WITH INVERTER TECHNOLOGY FOR STABLE ROOM CONDITIONS

IT COOLING CLOSE CONTROL AIR CONDITIONERS PRECISION AIR CONDITIONERS WITH INVERTER TECHNOLOGY FOR STABLE ROOM CONDITIONS IT COOLING CLOSE CONTROL AIR CONDITIONERS PRECISION AIR CONDITIONERS WITH INVERTER TECHNOLOGY FOR STABLE ROOM CONDITIONS IT COOLING CLOSE CONTROL AIR CONDITIONERS Extreme precision in temperature and humidity

More information

DC Inverter Chillers & DC Fan Coil Units

DC Inverter Chillers & DC Fan Coil Units 70-70 oercial ir onditioners 07/08 D Inverter hillers & D INVERTER oercial ir onditioner Division Midea Group dd.: Midea Headquarters Building, 6 Midea venue, Shunde, Foshan, Guangdong, hina Midea fter-service

More information

Refrigerated Air Dryers

Refrigerated Air Dryers Refrigerated ir Dryers Protect Pneumatic Equipment from Moisture! n air dryer removes the vapor from the moist compressed air delivered by the compressor, and prevents it from causing the pneumatic equipment

More information

AHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe

AHU N : Range: VERSO VERSO. Heat Recovery Air Handling Units. Plug & Play Energy Saving Smart Design Reliable & Safe HU N : 07.09.356 Range: VERSO Heat Recovery ir Handling Units VERSO Plug & Play Energy Saving Smart esign Reliable & Safe VERSO ir Handling Units VERSO-S air supply units VERSO-R air handling units with

More information

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series. RN/RQ Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS RQ Series Features: Air-cooled or water-cooled condenser, with unit capacities

More information